1. Cables Specifications subject to change without notice Copyright 2001 Acterna LLC All rights reserved FOST OF2X 0501 AE Acterna Global Headquarters 20400 Observation Drive Germantown Maryland 20876 4023 USA Toll Free 1 800 638 2049 or Tel 1 301 353 1550 Fax 1 301 444 8468 www acterna com Regional Sales Headquarters North America 20400 Observation Drive Germantown Maryland 20876 4023 USA Toll Free 1 800 638 2049 Tel 1 301 353 1550 Fax 1 301 444 8468 Latin America Av Eng Luis Carlos Berrini 936 8 9 Andar 04571 000 Sao Paulo SP Brazil Tel 55 11 5503 3800 Fax 55 11 5505 1598 Asia Pacific 42 Clarendon Street PO Box 141 South Melbourne Victoria 3205 Australia Tel 61 3 9690 6700 Fax 61 3 9690 6750 Western Europe Arbachtalstrasse 6 72800 Eningen u A Germany Tel 49 7121 86 2222 Fax 49 7121 86 1222 Eastern Europe Middle East amp Africa Elisabethstrasse 36 PO Box 13 2500 Baden Austria Tel 43 2252 85 521 0 Fax 43 2252 80 727 lst Neopalimovskiy Per 15 7 4th floor 119121 Moscow Russia Tel 7 095 248 2508 Fax 7 095 248 4189 Acterna is present in more than 80 countries To find your local sales office go to www acterna com ACTERNA Thre Eeepers a barrini era
2. The UPP universal push pull interface for the VFL and the power meter covers all 2 5mm connectors FC SC DIN E 2000 etc OFI 2000 offers s Stand alone high accuracy power meter Bi directional loss measured in under 15 Sec Fiber Optic Xpert ox functionality Telecom CATV applications Length Delay measurement Loss test set with 60 dB dynami range dka ph 1340 1550nm Laser Source Optical Return Loss Tester 4 Full duplex talkset with 45 dB dynamic range Short message functionality 1 VFL capacity i Up to 13 Ars Operation from rechargeable battery Cable result management for up to 40 cables with more than 1000 results ACTERWNA The Keepers of Communications Telecom Local Loop CATV DWDM Application Loss Test port Dynamic Range of Loss 60 dB Accuracy loop back 0 25 dB Side by side 0 15 dB Optical Interface Physical Contact PC or angled physical contact APC with fixed connectors or universal adapter BN 2060 details see ordering information Result Resolution 0 01 dB Test port sources Laser Types Laser Class 1 Wavelength range Spectral bandwidth 1310 30 nm 1550 30 nm 5 nm maximum Output Level into 9 125 um fiber CW mode modulated output average level 3 5 dBm 3 5 dBm 3 dB reduced Level stability Short term 15 min AAT 0 3 K Lon
3. 1550nm loss test stand alone power meter and delay length measurements Base unit types OFI 2001 1310 1550nm OFI Tester Telecom stand alone power meter with 10 to 70 dBm OFI 2002 1310 1550nm OFI Tester CATV stand alone power meter with 23 to 60 dBm Base unit options OFI Col Color Display Option OFI VFL UPP VFL option with UPP fixed connector Accessories for OFI family OFI RB Rechargeable Battery can be charged with OFI ACDC OFI AC DC AC DC Adapter OFI CASE Additional OFI Soft Case OFI CL Cigarette Lighter Power Adapter OFI CCS Connector Cleaning Sticks 5 pcs OFI OCT Optical Connector Cleaning Tape OFI SCT Spare Cleaning Tape for OFI OCT Optical Connectors for the loss test set One connector must be specified when ordering an OFI unit Standard fixed connectors FC PC SC ST DIN E2000 EC FC APC SC APC DIN HRL E2000 HRL UNI PC NAD PC connector or UNI APC NAD APC connector with use of adapters UNI FC AD UNI SC AD UNI ST AD or UNI DIN AD 2060 00 XX type Universal connectors Optical Adapter for Stand alone Optical Power Meter One Optical Adapter provided as standard the same type as the loss test set connector Other adapters are also available A SMA FC PC Diamond Biconic DIN VFO ST SC EC E2000 UPP2 5mm and UPP 1 25mm 2014 00 XX type For more information on test adapters cables and fiber optic couplers see the separate datasheet Fiber Optics Test Adapters and
4. Acterna OFI 2000 Family Bi Directional Optical Loss Test Set Setting a new standard for Optical Handhelds The OFI 2000 is designed for the professional installation verification maintenance and repair of large optical networks All in One Link Loss measurement Link Length Delay time measurement e System Power measurement e SMS short message system e Optical Return Loss optional e Visible Fault Location optional e 45 dB dynamic full duplex talkset optional Built in Fiber Optic Xpert FOX Functionality The OFI 2000 can measure store and transmit Link Loss Link ORL and Link Length With just one press of the FOX button calculate the average loss and the ORL automatically against user definable thresholds and at both wavelengths 1310 and 1550 nm Compatible with other Acterna products The OFI 2000 offers all the measurement facilities of the high performance handheld family including TWINtest and auto A wavelength Cable result management and reporting The OFI 2000 manages the test results and provides 3 levels of reporting 1 Job Summary 2 Cable Summary 3 Fiber details Optical interface connector flexibility Several optical interfaces connectors and adapters are available Universal or fixed connectors APC or PC interface can be chosen for the loss test port the power meter and the talkset Exchangeable adapters are provided for the most common 2 5mm connectors
5. g term 8 hours AAT 3 K 0 02 dB 0 2 dB Modulation frequencies 270 Hz 330 Hz 1 kHz 2 kHz Modes CW Continuous wave light Auto A Output signal includes information for Acterna Level Meters MOD Modulation for fiber identification 270 Hz 330 Hz 1 kHz 2 kHz TWINtest Both wavelength activated one after the other Test port power meter internal pigtailed photo detector Wavelength range Auto A detection incl TWINtest 1200 1650 nm 1310 1550 nm with Acterna Laser Sources Dynamic Range of Power Meter 0 to 80 dBm Detector type InGaAs Display resolution 0 01 dB Fiber type 9 um Application Stand alone high accuracy power meter Wavelength range adjustable per Telecom Local Loop CATV DWDM 800 1650 nm 850 1300 1310 1480 1510 1550 1625 nm and one user definable Selectable wavelength Auto A detection incl TWINtest 850 1310 1550 nm with Acterna Laser Sources Modulation Detection Dynamic range 10 to 70 dBm 270 Hz 330 Hz 1 kHz 2 kHz 26 to 55 dBm Accuracy Detector type Display resolution 0 2 dB 7 to InGaAs 2mm 0 01 dB 60 dBm 0 25 dB 23 to 50 dBm Filtered InGaAs 2mm 0 01 dB Fiber type Optical Interface 9 um up to 100 um 9 um up to 50 um Universal adapter BN 2040 details see ordering information Visible Fault Locator optional Wavelength 635 nm 1 mW max Outp
6. ut Power into 9 125 um fibre Optical interface UPP for all common 2 5mm connectors Off On 1 Hz Output modes Length Measurement Accuracy Accuracy L lt 3km 50m 3km lt L lt 200km 1 5 General basic configuration Display 1 4 VGA active b w display 5 7 inches color display optional see ordering information Power Supply removable 3 way dry batteries NiMH rechargeable battery AC DC Operating Time with dry batteries gt 8h Operating Time with NiMH accu gt 13h LOW BATT display A Auto off after 1 or 10 min or disabled v Battery charge indication A Operation with ac adapter A CE conform Ryd Operation temperature range 10 to 50 C Storage temperature range 20 to 70 C Weight without batteries incl all options 1 8 kg Dimensions w x h x d in cm approx 21 x 20x 8 Data transfer direct via RS232 J A Store function All parameters and values are subject to change without notice Optical Fiber Installation Tester Product information To ensure optimal use bi directional measurement and communication Two OFI units are required General information The OFI 200X unit is delivered as standard with a B amp W LCD screen RS232 interface and cable neck strap AC DC adapter soft case one battery pack with 6 dry batteries user manual lens tissue 1x30 pcs and connector cleaning sticks 5 pcs The basic functions are bi directional 1310