Home
User Manual - LaserTouchOne
Contents
1. LaserTouchOne gs LaserTouchOne 8 Introduction The LasefTouchOne User Manual Table of Contents Device Features and Controls Photo of device Product Contents Laser Safety Electrical Safer Instructions for Using the LaserTouchOne Charging the Unit 3 Holding the Device Treatment Steps Areas to Avoid Indications for Use Contraindications Warnings Precautions Care and Maintenance Warranty Sevens More Questions Technical Specifications Glossary oS Introduction The LaserTouchOne OTC The LaserTouchOne OTC refered to further as simply LTO is a rechargeable hand held pain therapy device I has a single diode laser for delivery of low level laser therapy referred to by some as a cold laser or LLLT The single laser Source is extremely low power c ImW and in the Class Ila ulatory classification for laser lights It operates at the 670 meg aneng The second hea delivered by the device is a micro current electrical stimulation similar to devices that are referred to as transcutaneous electrical nerve stimulators TENS but at a much lower level The device contains a rechargeable lithium ion battery The combined therapies are activated with an on off power button Treatment time is automatically set for two minute sessions The electrical stimulation and the laser light thera fir activae ar the sam
2. Safety Laser Safety Caution Do nor stare into the visible light Laser ligh is emitted from this device Avoid extreme exposure Do not point the device at anyone s eyes Electrical Safety Use care when plugging the power sd into the wall ute f r recharging LTO device See the picture below for the power charging unit which is provided with the device It is UL certified as safe for use wich this device Instructions For Use Chargi g the Ui The device will need to be fully charged prior to the first use Plug the AC recharging power cord into the unit and then into the wall socket Charge for at least 12 hours before the first use The unit will not operate unless the battery is charged Do not keep the device plugged into the charger when fully charged Recharge the device ar least once every 3 weeks whether you have used the device or not This is the charging unit which is supplied with your device Do not attempt to use another power recharger it may fail to recharge or can damage your device Holding the Device Generally the LTO device is best held as you would a pen with the index Finger on top to operate the power on off button This allows the middle Finger right hand or thumb left hand to manipulate the electrical stimulation e stim wheel or dial to control the ulse width intensity However you fray find ir s more comfortable to old in another position Treatment Step
3. 5258 Phone 480 588 7887 info renewaltechnologies com www LaserTouchOne com
4. e time by ping the omoto The pulse width eg intensity of the electrical stimulation variable and is controlled by you the user This is described in Treatment Steps on pages 6 and 7 It is recommended that the intensity of ter locken muon be krpt very low 30 that you barely fel it The combination of low level laser and micro current electrical stimulation will facilitate pain relief This combination of therapies has been shown to be effective ar very low levels of stimulation so setting the electrical stimulation dial ro a higher intensity is not necessary Ir is important that the cause of your pain be identified before you start treating it with any device including the LTO Device Features and Controls The following photograph shows the LTO device and the electroconductive gel used for treatment The steps for using the device follow on page 6 If this is your first use be sure the device is fully charged prior to use Rechargeable Power Cord Insert Power On Off Button Whee to control stimulation Treatment End Laser Output in Center Electrode Contact on each aide of laser Product Contents The shipping box should contain the following device components LasefTouchOne treatment unit Power cord for recharging the battery lt Tube of electoconductive gl Warranty card User Manual Inspect contents to ensure there is no obvious damage to the ETO treamene device or the el abe 2
5. eous Electrical Nerve Stimulation Waveform shape Pulsed rectangular Maximum output voltage 15V 500 ohm load 150V 10K ohm load Maximum output 30 mA peak at 500 ohm load Pulse widrh 6 80 psec Frequency Hal 1096 Pulse period nS Maximum current density 023 mAJem2 average 500 ohms Maximum power density 0 0034 Wiem2 average 500 ohms Maximum charge per pulse 36 pJ 500 ohms or 4 uC 500 ohms Power Rechargeable Battery Lithium fon Glossary ADJUNCTIVE TREATMENT Treatment used together with the primary treatment Its purpose isto assist the primary treatment CARDIAC ARRHYTHMIA An abnormal rate of muscle contractions in the heart CONTRAINDICATIONS To make a treatment or procedure inadvisable DIODE An electrical device with rwo active terminals an anode and a cathode through which current passes more easly in one direction ELECTROCONDUCTIVE Having the property or capability of conducting electricity FDA Food and Drug Administration INTRACTABLE PAIN Pain chat is hard to treat relieve difficult to solve alleviate or cure LLLT Low Level Laser Therapy often referred to as Cold Laser OTC Available without a prescription Over The Counter TENS Transcutaneous electrical nerve stimulators 15 Renewal Technologies 10446 N 74th Street Suite 120 Scottsdale AZ 8
6. evice should malfunction due to defective materials and or workmanship it is fully guaranteed for one year from the date of purchase providing the enclosed warranty card is mailed to Renewal Technologies within 10 days of purchase the LTO is returned for servicing to Renewal Technologies the LTO is not misused altered or serviced by any person or entity other than Renewal Technologies the electroconductive gel provided with the product is the only type of gel to be used with the LTO device the LTO is used according to these instructions and in the manner intended Use of a different recharging unit or a different type of eleeroconductive gel wil aid the 1 ycar warranty Service If servicing is needed for your LTO please mail your LTO and charger to Renewal Technologies Renewal Technologies LLC 10446 N 74th Street Suite 120 Scottsdale AZ 85258 Include the following information with your unit name address for return phone number and e mail address Renewal Tech will contact you with Sn excite of cl to compl any cpl one Under warranty and arrange for payment More Questions Call or e mail Renewal Technologies for any additional information at 877 751 7665 or info renewaltechnologies com View instructional videos at www LaserTouchOne com LaserTouchOne Specifications Laser TASER Type Laser Diode Wavelengeh 70am s lOnm Power 12m Transcutan
7. h the power button i again It is recommended that you start S R om or two oe insu fr a particular area of pain and repeat this Upto Bre coc throught the da Usually treatment with the LTO uies little or no pressure to the area fog teed Homo inarae witha lo of muscle or fat a more firm application may be necessary although the pressure applied should not be painful Areas to Avoid Parts of the head face and front of the neck CAROTID SINUS The location of the carotid sinus is illustrated in this drawing Care should be taken to avoid the carotid sinus as the electrical f stimulation may cause a muscle spasm THE EYE Take particular care to avoid treatment of and around the eye Avoid direct exposure of the laser light to the eyeball Remember do not look into the laser light and do not point the light at anyone s eyes You can tell that the device is on by seeing the light from the side through the plastic tip Vv Carotid Sinus Indications for Use The LasefTouchOne device combines a low level laser and micro current electrical stimulation This combination of low level light and electrical stimulation provides sympromatic relief of chronic intractable pain and is indicated for adjunctive treatment of postsurgical and post traumatic acute pain and for adjunctive use in providing temporary relief of minor chronic neck and shoulder pain of musculoskeletal origin Contraindicatio
8. in treating pain of central origin including headache z x TENS devices are not a substitute for pain medications and other pain management therapies Since the effects of stimulation of the brain are unknown avoid use across the head TENS devices have no curative value TENS is a symptomatic treatment and as such su the sensation of pain that would otherwise serve as a poecive mechanism This is particularly important in the use following surgical procedures Keep the device out of the reach of children Some patients may experience skin irritation or Ippon oy the electrical mulation othe trical conductive medium gel Care should be taken by patients whose skin in areas lack normal sensation Care and Maintenance Like any electronic product the LTO requires proper care and handling The following is recommended Do not disassemble the device Do not try to remove the clear cover at tip of unit Do not drop the device or handle it roughly Do not immerse the device in water or any liquid Use the gel sparingly only a small amount is needed on the skin After each treatment wipe the treatment end of the device clean of any gel with a slightly damp cloth fusing che device on mote than one person carefully decontamtnare the testment ed including the stainless steel electrodes with a moist alcohol wipe 12 Warranty The LasefTouchOne carries a 1 year warranty IF your d
9. ns This device is contraindicated in patients with cardiac pacemakers implanted defibrillators or other implanted devices Warnings Because the device contains a laser do not shine it directly into your eyes or look directly at the laser light Do not point che LTO device at your or another person s eyes The safety of TENS devices on pregnant women has nor been established The device should be applied only to normal intact clean cin Now that the device aay he applied to bruised skin although care should be taken to reduce any pressure Avoid use over open wounds or molier cred or inflamed ura rca eruption Avoid use of the LTO device along the eye area or tam the Bene or sides ofthe meck at the carotid avery shown ar lefi Avoid use of the LTO device over or in the area of cancerous lesions The device should not be used during the following bathing or showering sleeping driving or operating machinery Do not look into the laser Tight and do not point the ight at anyone s eyes 10 Precautions Tf you have a suspected or diagnosed heart condition such as irregular heart bear cardiac arryhthmia or epilepsy you should consule with your physician before using the LTO device to treat any pain condition The long term effects of prolonged exposure to nom thermal laser and electrical stimulation are unknown Electrical stimulation TENS is not known to be effective
10. s Step 1 Adjust the E Stim Wheel Turn che dial e stim wheel on the side of the device completely toward che minus sign as shown by the arrow Stel ly Gel Apply a small amount of gel to eae you wish to pieli E Step 3 Turn on the LaserTouchOne Push the on off burton on the LTO once Step 4 Apply the LaserTouchOne Use a painestroke or circular 1 moc to trea the painful area Adjust the dial toward the sitive 1 sign until you feel lighe gle Remove your A Finger from the dial leaving it ar that setting NOTES REGARDING SETTING THE ELECTRICAL STIMULATION INTENSITY If you have limited or no skin sensitivity in the area you plan to treat test the intensity of che stimulation on a sensitive area such as between your thumb and first finger or on top of your hand before starting treatment Thi wll enne tha you do not tu the sexig ma high Effective treatment can be achieved with only a slighe tingle sensation of the micro current electrical stimulation Be sure to treat the area of immediate pain and also surrounding areas that may theo be afc by the immodine aca of pain Step 5 Continue For Up To Five Treatment Sessions Per Day Continue moving the unit ina paint stroke or circular motion in the desired area until the LTO and the red light turn off The unit will turn off automatically after 2 minutes o If you desire to stop the unit at any y point simply pus
Download Pdf Manuals
Related Search
Related Contents
Philips Spot light 32031/11/66 SMiT Professional CAM User Guide WBT User Manual.indd USER GUIDE: CSPRO DATA ENTRY AND ANALYSIS SOFTWARE Avira Benutzerhandbuch MAIA xxxxx Service de Gestion de Cas SV 31 Acoustic Calibrator ViperXTR CTQx CLSI 8081408(201012) Sun Gigabit Ethernet PCI Adapter 1.0 Product Notes 9 - Qarbon Copyright © All rights reserved.