Home
PC-BX05 People Counter Installation Guide & User`s Manual
Contents
1. 1257 Salt Springs Rd Youngstown OH 44509 1612 Phone 800 239 1226 Fax 877 517 2586 Commercial www SenSourceInc com Industrial www SenSource biz PC BX05 People Counter Installation Guide amp User s Manual GETTING STARTED PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLATION When installed as explained below the photoelectric sensor emits an invisible beam of light that travels across a maximum distance of 5 meters 16ft between sensor and the reflector When a person crosses this beam a digital signal is sent to the counter incrementing its display by 1 This unit counts up regardless of the direction of traffic entering or exiting Removal of power to the display does not reset the counter It will maintain its count until the reset button on the display is depressed This system operates with a safe low voltage 12V DC supply included Components e Counter Display e Retroreflective Photoelectric Sensor With 10ft Cable W25xH65xL75mm e MS 4 Round Reflector 80mm diameter e 12V DC Power Supply With 10ft Cable Optional Components e Count Recorder e Chime e Magnetic Reset INSTALLATION By following the simple guidelines below your people counter will be operating within a few minutes 1 Adding Cable Length Skip this step if you plan on using the standard 10ft cable provided 1 1 You may use your own cable according to the specifications listed in figure 2 if you wish to extend the di
2. ONAL 22AWG 2 Conductor Z WHITE WHITE PCDL 1000 CHIME OPTIONAL 22AWG 3 Conductor Figure 2 Sensing Area Max Dist 5 Meters 16ft Dimensions Reflector 12V DC Supply 120 VAC Outlet Display Figure 3 Page 3 of 4 Top View of Entry Typical Installations Option 1 SENSOR REFLECTOR MOUNTING amp ALIGNMENT Reflector Option 2 Noe Sensor Front View of Entry Reflecto ee Page 4 of 4 20 ma N Reflector Reflector 16ft Max N Sensor Option 3 Sensor Sensor should be mounted at about 3 4ft above ground level aim at the torso or higher or 4 oft to ignore children in counts Figure 4
3. ity and signal delay located under the sensor cover These settings are factory set and should not require adjustment If adjustment becomes necessary due to unforeseen conditions the time delay or sensitivity can be increased or decreased by rotating the appropriate adjustment using the small blue screwdriver provided Turning clockwise will increase and counterclockwise will decrease Increasing the time delay is generally used to count groups of people as one count 5 Your Counting System Is Ready For Operation 0 Is Resetting the Display Pressing the black button to the right of the display will reset the counter back to zero If system is equipped with magnetic reset apply supplied magnet to the area labeled reset 1Optional component 2Not available on all systems 3Location may vary WIRING DIAGRAMS Yellow amp Green LEDs Reflector Aim Sensor Face At Reflector Mounting Bracket WARNING DO NOT AIM YELLOW Washer S Grommet LED AT THE REFLECTOR SYSTEM WILL NOT OPERATE Figure 1 Page 2 of 4 COUNTER DISPLAY FRONT B laste COUNTER DISPLAY BACK of ae y A _ ri l 12V DC J Power Supply 1 N RED ven 22AWG 2 Conductor AC RESET AREA Ae fe BX05 Sensor STAB OUT Green Yellow og 22AWG 3 Conductor sayoums d q MON MIN x MAX is SENS os SIL f Yellow Light BLACK BLACK COUNT RECORDER OPTI
4. sensor power supply Count Recorder and chime to the back of the display according to the wiring diagram while adhering to the wiring codes established for your state and locality Excess wire length can be trimmed If a Count Recorder is being used please follow the included instructions with the Count Recorder along with the wiring guide in figure 2 4 Aligning and Mounting Reflector 4 1 4 2 4 3 4 4 After the sensor display and optional components have been mounted and wired connect the power supply to a 120V AC outlet and take note of the lights on the sensor Focus your attention on the yellow light The sensor and reflector should be aligned so that the yellow light is NOT illuminated when nothing is blocking the path between the sensor and the reflector the green light may or may not be on If the yellow light is illuminated adjustments to the alignment of the reflector need to be made until the yellow light remains off with nothing blocking the beam Further adjustments to the sensor alignment can be accomplished by loosening the screws on the sensor bracket in order to point the sensor up or down or side to side Once aligned properly the yellow light will NOT be illuminated When the beam is broken the yellow light will illuminate and the count will be incremented by 1 Make sure to secure the reflector and sensor in order to maintain alignment The photoelectric sensor includes adjustments for both sensitiv
5. stance from the components up to 1000ft with shielded cable To remove the sensor cover loosen the screw on the sensor housing and pull the cover off exposing the wire terminals Refer to Figures 1 and 2 2 Mounting Components 2 1 Sensor The sensor should be installed securely using the mounting brackets supplied with the sensor at a level that people will break the beam mounting screws not included The sensor is most effective when mounted about 3 4ft above the ground aim at the torso section or 4 5ft to ignore children in counts Plan to mount the reflector directly across from the sensor at a distance no greater than 5 meters 16ft but DO NOT PERMANENTLY MOUNT THE REFLECTOR UNTIL STEP 4 Mounting suggestions are located in figure 4 Refer to Figures 3 and 4 2 2 Display and or Chime The display or chime can be set in any convenient indoor location or mounted to a secure surface using the mounting flanges 2 3 Count Recorder If your system is equip with a PCDL 1000 Count Recorder it is suggested to mount the Count Recorder using Velcro soft side applied to Count Recorder in an area with easy access but is limited to personnel only Page 1 of 4 3 Wiring Components 3 1 3 2 Power Supply Transformer Your system comes with a 2 conductor red blk cable with fork connectors on one end Connect the fork terminals to the white power supply CHECK POLARITY Refer to Figure 2 Display Connect the wires from the