1. 32 inputs 32 outputs An example of when the SI unit station number is set to 01 is shown below Master station buffer area I O memory map of EX140 SMJ1 e g QJ61BT11N For station number 1 Buff Buff abs Remote input ee Remote output w a Remote output RX memory memory address address EY RY EOH RXOF to RXOO _160H__ RYOF to 0 RXOO DE m ee Unused ean axa o Ro 164 RYaF o RYO gt Esh _ RX5FtoRx50 165H_ RYSF to RY50 LESH RX6F to RX60 166H RY6F to 0 E8H RX8F to 5880 168H RY8F to RY80 Dor Output No 15 a RX7F to RX70 167H RY7F to RY70 i S RX9F to RX90 169H RY9F to 0 600 10 EAH RXAF to RXAO 16AH__ RYAF to RYAO EBH RXBF to RXBO 16BH RYBF to RYBO EBH 16BH 559089 elefedejfef RX1F F RYIF F Unused area cannot be used When remote I O station is assigned to buffer area the area of 32 inputs 32 outputs will be used O Solenoid valve OFF 1 Valve ON 0 No EXX X OME0011 H 2 Output number assignment The output number refers to the SI unit side solenoid position on the manifold and starts at Zero oza 6 8 poraa EEK CLIO Valve maifold Solenoid on side B Standard wiring of the manifold is for double solenoid valves and the output number starts at the A side and then B side in that order as shown in the figure a If a single solenoid valve is mounted on the standard wiring manifold the output number for the
2. DANGER indicates a hazard with a high level of risk which if not avoided Danger will result in death or serious injury The compatibility of the product is the responsibility 01 the person who designs the equipment or decides its specifications Since the product specified here is used under various operating conditions its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product This person should also continuously review all specifications of the product referring to its latest catalogue information with a view to giving due consideration to any possibility of equipment failure when configuring the equipment Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembly operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced 3 Do not service or attempt to remove product and machinery equipment until safety is confirmed 1 The inspection and maintenance of machinery equipment should only be performed after measures to prevent falling or runaway of the driven objects have been co
3. that the SI unit control power Investigate the cause of the voltage supply voltage is within the specified 15 to 30 VDC fluctuation and take countermeasures range against it Check that the solenoid valve power Investigate the cause of the voltage supply voltage is within the specified 24 VDC 10 5 fluctuation and take countermeasures range against it 0 No EXX X OME0011 H Troubleshooting o Troubleshooting Applicable model EX140 SMuJ1 If an operation failure of the product occurs please confirm the cause of the failure from the following table If a cause applicable to the failure cannot be identified and normal operation can be recovered by replacement with a new product this indicates that the product itself was faulty Problems with the product may be due to the operating environment network construction etc Please consult SMC If the cause of the problem cannot be found and the SI unit is not faulty then inconsistencies with parameter settings or the network construction at the master station is possible In this case please refer to the troubleshooting section of the CC Link master user s manual by Mitsubishi Electric Corporation Solenoid valve Only the solenoid Solenoid valve malfunction valve LED is ON failure SI unit PWR Refer to Fault Yes LED is OFF No 1 No lt lt m SI unit RD Refer to Fault LED is OFF No 2 SI unit L RUN SI unit L ERR Refer to Fault LED is OFF LED is OFF No 3 Ref
4. 2 5 M 5 M 10 Mbps Cable length between stations Max cable length 1200 900 400 160 100 m 15 to 30 VDC 24 VDC 10 5 16 outputs Sink NPN positive common 0 1 Aor less IP20 1500 VAC 1min Between FG and external terminal Insulation resistance 2 MQ or more 500 VDC between FG and external terminal 20 cm or more Operating temperature 0 to 55 C when 8 outputs are used Environment Ambient temperature 0 to 50 C when 16 outputs are used Storage 10 to 60 C Ambient humidity 35 to 85 RH no condensate Pollution degree Pollution degree 3 Operation atmosphere No corrosive gas No dust Standard CE marking Weight 80 g or less EX140 is IP20 rated When operating this product in a pollution degree 3 environment mount it onto an IP54 rate or higher controller board etc Applicable solenoid valve series Representative series Applicable series 501000 2000 series 523000 95 0 No EXX X OME0011 H aDimensions U U i 20280288 in ee EX140 SMJ1 No EXX X OME0011 H Revision ay B New format C Error correction D Add the precautions and change into the latest format E Terminal screw change F Modified errors in text Page 10 G Limited warranty and Disclaimer are added H Contents revised in several places SMC Corporation 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www sm
5. B side valve is skipped Custom wiring for mixed mounting single solenoid valves and double solenoid valves can be specified with a Wiring Specification Sheet Example wiring is shown in the figure b x Bit status 0 and 1 in the data corresponds to solenoid valve status OFF and ON 0 OFF 1 ON and the output number starts at zero from LSB least significant bit fig a fig b Double Single Double Double Double Single Double Double No No Station Station No No No EXX X OME0011 H ESE Mounting and wiring Item to inspect Are SI unit terminals for communication and power No looseness supply securely connected Tighten the connector Refer to Mounting Installation Are the terminating resistors securely connected to both ends of the Terminating resistors must be network when the SI unit is at the connected end of the network lf isibl k f h Is the connecting cable broken No apparent breaks cae visible breaks are found replace the Replacement parts item to inspect isi isi h d dieat d cable No visible error and the correct If any visible breaks are found replace the cable must be used cable If it does not operate as intended or the display indicates errors replace the unit Connect suitable terminating resistors to cables Refer to Mounting Installation SI unit No error in operation and display ePower supply item to inspect Check
6. No EX gt lt gt x OME0011 H Operation Manual PRODUCT NAME SI unit for CC Link MODEL Series Product Number EX140 SMJ1 Series SMC Corporation LEL CRR C Safety Instructions 2 Model Indication and How to Order 7 Summary of Product parts 7 Definition and terminology 7 Mounting and Installation 8 Communication wiring 8 Power supply wiring 10 Settings 10 Maintenance 14 Troubleshooting 15 Specifications 18 Specifications 18 Dimensions 19 No EXX X OME0011 H Safety Instructions These safety instructions are intended to prevent hazardous situations and or equipment damage These instructions indicate the level of potential hazard with the labels of Caution Warning or Danger They are all important notes for safety and must be followed in addition to International standards ISO IEC and other safety regulations 1 ISO 4414 Pneumatic fluid power General rules relating to systems ISO 4413 Hydraulic fluid power General rules relating to systems IEC 60204 1 Safety of machinery Electrical equipment of machines Part 1 General requirements ISO 10218 1992 Manipulating industrial robots Safety etc A Amie CAUTION indicates a hazard with a low level of risk which if not avoided f Caution could result in minor or moderate injury _ WARNING indicates a hazard with a medium level of risk which if not N Warning avoided could result in death or serious injury i l
7. ailure due to the deterioration of rubber material are not covered by the limited warranty Compliance Requirements 1 The use of SMC products with production equipment for the manufacture of weapons of mass destruction WMD or any other weapon is strictly prohibited 2 The exports of SMC products or technology from one country to another are governed by the relevant security laws and regulation of the countries involved in the transaction Prior to the shipment of a SMC product to another country assure that all local rules governing that export are known and followed No EXX X OME0011 H Operator This operation manual is intended for those who have knowledge of machinery using pneumatic equipment and have sufficient knowledge of assembly operation and maintenance of such equipment Only those persons are allowed to perform assembly operation and maintenance Read and understand this operation manual carefully before assembling operating or providing maintenance to the product aSafety Instructions mDo not disassemble modify including the replacement of the circuit board or repair the product Do not use the components other than the specified components An injury or failure can result wm Do not operate the product outside of the specifications Do not use for flammable or harmful fluids Fire malfunction or damage to the product can result Verify the specifications before use wm Do not operate in
8. air before performing maintenance There is a risk of unexpected malfunction ePerform regular maintenance and inspections There is a risk of unexpected malfunction eAfter maintenance is complete perform appropriate functional inspections Stop operation if the equipment does not function properly Otherwise safety is not assured due to an unexpected malfunction or incorrect operation Do not use solvents such as benzene thinner etc to clean the each unit They could damage the surface of the body and erase the markings on the body Use a soft cloth to remove stains For heavy stains use a cloth soaked with diluted neutral detergent and fully squeezed then wipe up the stains again with a dry cloth No EXX X OME0011 H Model Indication and How to Order EX140 SMJ 1 Output type 16 outputs NPN positive common sink Fieldbus Summary of Product parts No To connect to functional ground 6 Switch setting area Switches for setting the station number and transmission speed m Definition and terminology Total number of stations occupied by all slaves connected to the CC Link 1 Number of stations network 5 Numbers assigned to the slave stations from 1 to 64 with No 0 assigned to the 2 Station number CC Link master Slave stations must be assigned numbers according to the number of occupied stations so they are not duplicated 3 Slave station General term for any station other than the master statio
9. an atmosphere containing flammable or explosive gases Fire or an explosion can result This product is not designed to be explosion proof alf using the product in an interlocking circuit Provide a double interlocking system for example a mechanical system eCheck the product regularly for proper operation Otherwise malfunction can result causing an accident m The following instructions must be followed during maintenance Turn off the power supply eStop the air supply exhaust the residual pressure and verify that the air is released before performing maintenance Otherwise an injury can result No EXX X OME0011 H After maintenance is complete perform appropriate functional inspections Stop operation if the equipment does not function properly Safety cannot be assured in the case of unexpected malfunction mProvide grounding to assure the safety and noise resistance of the Serial System Individual grounding should be provided close to the product with a short cable aNOTE oFollow the instructions given below when designing selecting and handling the product e The instructions on design and selection installation wiring environment adjustment operation maintenance etc described below must also be followed Product specifications When conformity to UL is required the SI unit should be used with a UL1310 Class 2 power supply The SI unit is a UL approved product only if they have a kus mark on the
10. ation and supply cables from the LED is OFF power supply cables noise sources and L ERR LED is OFF Station numb r Check that the SI unit station number setting and the setting in the master setting error station are the same Correct the setting Communication Check that the SI unit communication speed setting speed setting and the setting in the error master station are the same Station number setting error or SI unit L RUN duplicate station LED is OFF number error and LERR LED is ON Communication speed setting error Check that the station number settings contain no errors and no duplications Correct the setting To review the setting method see Settings Check that the communication speed is set correctly 0 No EXX X OME0011 H Trouble Correct the setting Correct the settings with the power supply turned off and then supply the power again Separate the communication and power supply cables from the noise sources Check the troubleshooting section of the solenoid valve manual or contact SMC Correct the connection between the SI unit and solenoid valve manifold Correct the total number of outputs connected to the EX140 SMJ1 unit to 16 outputs or less No EXX X OME0011 H Check that the SI unit communication speed setting and the setting in the master station are the same Check that the station number settings contain no errors and no duplicat
11. body eUse the specified voltage Otherwise failure or malfunction can result eReserve a space for maintenance Allow sufficient space for maintenance when designing the system Do not remove any nameplates or labels This can lead to incorrect maintenance or misreading of the operation manual which could cause damage or malfunction to the product It may also result in non conformity to safety standards eProduct handling Installation Do not drop hit or apply excessive shock to the fieldbus system Otherwise damage to the product can result causing malfunction Tighten to the specified tightening torque If the tightening torque is exceeded the mounting screws may be broken Never mount a product in a location that will be used as a foothold The product may be damaged if excessive force is applied by stepping or climbing onto it Wiring eAvoid repeatedly bending or stretching the cables or placing heavy load on them Repetitive bending stress or tensile stress can cause breakage of the cable Wire correctly Incorrect wiring can break the product Do not perform wiring while the power is on Otherwise damage to the fieldbus system and or I O device can result causing malfunction Do not route wires and cables together with power or high voltage cables Otherwise the fieldbus system and or I O device can malfunction due to interference of noise and surge voltage from power and high voltage cables to the signal line Ro
12. cworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacturer 2010 2015 SMC Corporation All Rights Reserved 0 No EXX X OME0011 H
13. er to Fault No 4 SI unit SD Refer to Fault LED is OFF No 5 SI unit L ERR Refer to Fault LED is flashing No 6 Solenoid valve malfunction SI unit has no error Refer to Fault No 7 0 No EXX X OME0011 H oFaults and countermeasures Trouble S Check the SI unit control power supply cables for breaks and check that the terminals are not loose Connect the power supply Avoid repetitive bending and stress cable correctly SI unit control power supply iring fail SI unit PWR on the cables which may cause LED is OFF damage Check the SI unit control power Coe TEN SI unit control supply wiring for any errors 9 power supply failure Check the SI unit control power Supply 15 to 30 VDC to supply voltage the SI unit control Check the communication cables for breaks and check that the terminals Connect the communication cable correctly are not loose Avoid repetitive bending and stress on the cables which may cause damage Check the communication wiring for 0 Correct the wiring any errors M aster station chek terner E Connect the power supply power supply to the master station 3 SI unit PWR LED is ON Communication and wiring failure RD LED is OFF master station failure correctly Check that there are no high voltage Separate the Communication cables or equipment that generates communication and power SI unit L RUN failure noise around the communic
14. ewdriver entry to access the terminal screw is 06 mm The terminal screw is an M3 cross head screw The applicable size of the cross head screwdriver is No 2 06 mm or less Tighten the screws securely with a torque of 0 5 to 0 6 Nm Note Connect the ground terminal to ground Resistance to ground should be 100 ohms or less A Single power supply used B Dual power supplies used S a oS N Solenoid valve SI unit control 24 VDC power supply power supply 24 VDC 24 VDC Fig 6 oDisplay setting B RATE STATION No PWR L RUN LERR SD RD 00 x10 x1 OOS Display PWR LED is ON when the communication power is ON Indicates whether the SI unit is communicating with the master station correctly LED is ON when the SI unit is receiving normal data from the master station LED is OFF during time out LED is ON when data is being sent RD LED is ON when data is being received LED is ON during communication errors CRC errors LED is OFF during time out L RUN LED is also OFF LED is ON during station number setting and communication speed setting errors the LED will turn off when the setting has been corrected and power has been restored LED flashes when the station number or communication speed settings have changed during communication the L RUN LED will turn on and the SI unit will operate according to the new settings once power is restored If the data link i
15. ions Check that the communication speed setting has not changed while the SI unit power is supplied Check that the station number setting has not changed while the SI unit power is supplied Check that there are no high voltage cables or equipment that generates noise around the communication and power supply cables Replace the solenoid valve with another and check the operation or check the troubleshooting section in the solenoid valve manual Check the connector between the SI unit and solenoid valve manifold for a connection failure such as a bent pin Check that the total number of outputs for the connected solenoid valves is 16 or less 00 Communication speed setting error Station number setting error or duplicate station number error Communication speed change error Station number setting change error Communication failure Solenoid valve failure Connection failure between SI unit and solenoid valve manifold Too many solenoid valves more than 16 outputs SI unit RUN LED is ON and SD LED is OFF SI unit RUN LED is ON and ERR LED is flashing Solenoid valve malfunction Specifications Specifications Model No EX140 SMJ1 Applicable system CC Link Ver 1 10 Occupied station 1 station in A number setting 1 to 64 Set with a rotary switch Communicatan Station type Remote I O specification Communication speed 156 k 625 k
16. n Number of networked stations in use by a slave Depending on the data one to 4 Number of occupied slaves four stations can be set The remote I O only occupies one station A ion which can only use digital data Occupies only one station 5 Remote I O ae A y 9 p y Example digital units solenoid valves sensors etc No EXX X OME0011 H Mounting and Installation Communication wiring The connection between a CC Link dedicated cable and an SI unit communication terminal for CC Link is show hole diameter for the screwdriver entry to access the terminal screw is 06 mm The terminal screw is an M3 cross head screw 1 Be sure to connect each signal line to its dedicated terminal Refer to Fig 1 The applicable size of the cross head screwdriver is No 2 p6 mm or less Tighten the screws securely with a torque of 0 5 to 0 6 Nm Blue White Yellow Shield Fig 1 2 Be sure to connect a terminating resistor between DA and DB at both ends of the CC Link system Refer to Fig 2 Use a CC Link dedicated cable or a cable with the same specifications If a cable with any other specifications is used normal data transmission cannot be guaranteed Master unit Remote unit Local unit Teminat z Blue m r m r Terminati erminating erminating CC Link dedicated cable CC Link dedicated cable Fig 2 3 The appropriate terminating resistor varies depending on the CC Link cable u
17. nfirmed 2 When the product is to be removed confirm that the safety measures as mentioned above are implemented and the power from any appropriate source is cut and read and understand the specific product precautions of all relevant products carefully 3 Before machinery equipment is restarted take measures to prevent unexpected operation and malfunction 4 Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions 1 Conditions and environments outside of the given specifications or use outdoors or in a place exposed to direct sunlight 2 Installation on equipment in conjunction with atomic energy railways air navigation space shipping vehicles military medical treatment combustion and recreation or equipment in contact with food and beverages emergency stop circuits clutch and brake circuits in press applications safety equipment or other applications unsuitable for the standard specifications described in the product catalogue 3 An application which could have negative effects on people property or animals requiring special safety analysis 4 Use in an interlock circuit which requires the provision of double interlock for possible failure by using a mechanical protective function and periodical checks to confirm proper operation No EXX X OME0011 H The product is provided for use in manufacturing industries The product herein de
18. ning strikes Take measures against lightning strikes in the system Prevent foreign matter such as remnant of wires from entering the fieldbus system to avoid failure and malfunction eMount the product in a place that is not exposed to vibration or impact Otherwise failure or malfunction can result Do not use the product in an environment that is exposed to temperature cycle Heat cycles other than ordinary changes in temperature can adversely affect the inside of the product eDo not expose the product to direct sunlight If using in a location directly exposed to sunlight shade the product from the sunlight Otherwise failure or malfunction can result Keep within the specified ambient temperature range Otherwise malfunction can result Do not operate close to a heat source or in a location exposed to radiant heat Otherwise malfunction can result Adjustment and Operation eSet the switches by using a sharp pointed screwdriver etc lt may damage set switches ePerform settings suitable for the operating conditions Incorrect setting can cause operation failure For details of each setting refer to page 10 of this manual Please refer to the PLC manufacturer s manual etc for details of programming and addresses For the PLC protocol and programming refer to the relevant manufacturer s documentation Maintenance Turn off the power supply stop the supplied air exhaust the residual pressure and verify the release of
19. s normal PWR L RUN SD and RD LED s will be ON 10 0 No EXX X OME0011 H oSwitch setting The setting for the station number and communication speed can be carried out using the rotary switches under the SI unit cover The setting for HOLD CLEAR can be carried out using the DIP switch under the SI unit cover The settings must be carried out with the power supply for the SI unit turned off 222202000000 Station number setting STATION NO SW2 SW3 x10 0 to 6 The station number should be set within the range of 01 to 64 If the number is set to 00 or to 65 or above the L ERR LED will turn on The station number must not be duplicated this will cause an error The default setting is 00 Communication speed setting ERATE W1 0 156kbps 4 10Mbps The communication speed should be set within the range of 0 to 4 If the setting is out of range the L ERR LED will turn on Turn the power off and correct the setting Set the same communication speed as the master station The default setting is 0 156 kbps HOLD CLEAR setting 504 HOLDICLEAR HOLD CLEAR Clear the output when an error occurs HOLD Hold the output when an error occurs CLEAR x The default setting is CLEAR 3 No EXX X OME0011 H oOutput and error information 1 I O mapping table for master station Buffer Memory EX140 SMuJ1 is a remote I O station 1 station occupied
20. scribed is basically provided for peaceful use in manufacturing industries If considering using the product in other industries consult SMC beforehand and exchange specifications or a contract if necessary If anything is unclear contact your nearest sales branch Limited warranty and Disclaimer Compliance Requirements The product used 15 subject to the following Limited warranty and Disclaimer and Compliance Requirements Read and accept them before using the product Limited warranty and Disclaimer 1 The warranty period of the product is 1 year in service or 1 5 years after the product is delivered whichever is first 7 Also the product may have specified durability running distance or replacement parts Please consult your nearest sales branch For any failure or damage reported within the warranty period which is clearly our responsibility a replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalogue for the particular products 2 Vacuum pads are excluded from this 1 year warranty A vacuum pad is a consumable part so it is warranted for a year after it is delivered Also even within the warranty period the wear of a product due to the use of the vacuum pad or f
21. sed Refer to the table and Fig 3 below Cable type Terminating resistor CC Link dedicated cable 1 1 1 110 Q 1 2 W Brown Brown Brown CC Link dedicated cable compatible to Ver 1 10 CC Link dedicated high performance cable 130 Q 1 2 W Brown Orange Brown mE Terminating resistor Fig 3 No EXX X OME0011 H 4 The CC Link dedicated cable s shield wire SLD should be connected to the FG terminal of the SI unit For the EX140 SMu1 the SLD terminal and FG terminal are common Therefore connect 3 wires to the FG Terminal as shown in Fig 4 SI unit O 2220222020 SLD line SLD line Fig 4 Wiring to the FG terminal FG line on the SI unit When connecting 3 wires to the FG terminal crimp 2 wires together into one crimped terminal as shown in Fig 5 Use another crimped terminal for other wires After crimping connect wires so that the back of the two crimped terminals face each other 5 Fig 5 How to crimp the terminal No EXX X OME0011 H Power supply wiring Connect the power supply wiring to the solenoid valve power supply terminals and to the SI unit control power supply terminals Although the power supply consists of two separate systems it is possible to use either a single power supply or separate power supplies Be sure to connect the power supply to the correct terminals Refer to Fig 6 The hole diameter for the scr
22. ute the wires piping of the fieldbus system and or I O device separately from power or high voltage cables Confirm proper insulation of wiring Poor insulation interference from another circuit poor insulation between terminals etc can lead to excess voltage or current being applied to the product causing damage lake appropriate measures against noise such as using a noise filter when the fieldbus system is incorporated into equipment Otherwise noise can cause malfunction No EXX X OME0011 H Environment Select the proper type of protection according to the environment of operation In case of IP20 avoid use in the place where water and oil scatter Do not use the product in an environment where corrosive gases or fluids could be splashed Otherwise damage to the product and malfunction can result Do not use in an area where surges are generated If there is equipment which generates a large amount of surge solenoid type lifter high frequency induction furnace motor etc close to the fieldbus system this may cause deterioration or breakage of the internal circuit of the fieldbus system Avoid sources of surge generation and crossed lines When a surge generating load such as a relay or solenoid is driven directly use an fieldbus system with a built in surge absorbing element Direct drive of a load generating surge voltage can damage the fieldbus system The product is CE marked but not immune to light
Download Pdf Manuals
Related Search
English english to spanish english to russian english to french english to japanese english to korean english to german english english to spanish translation english to tamil english to chinese english to tagalog english to italian english to hindi english to arabic english to latin english to tagalog translator english bulldog english to telugu english to marathi english to vietnamese english to spanish google translate english alphabet english breakfast english language english keyboard
Related Contents
Document PDF - GPS Tracker pour l`automobile 運転席フロアマットの正しい使い方 Guide de référence Easyspray et Duplospray UM_Liquid E600_(solo)_DE_v1.book Manual de Usuario Administrativos JVC GET0598-002B User's Manual Philips AVENT Night Time Pacifiers SCF176/18 Cyber Acoustics IC-1002RD Copyright © All rights reserved.