Home
        - Omron Industrial Automation Vietnam
         Contents
1.    OMRON       Ordering Information    International Standards    NX ECC    e The standards are abbreviated as follows  U  UL  U1  UL Class   Division 2 Products for Hazardous Locations   C  CSA  UC  cULus  UC1  cULus  Class   Division  2 Products for Hazardous Locations   CU  cUL  N  NK  L  Lloyd  CE  EC Directives  and KC  KC Registration   e Contact your OMRON representative for further details and applicable conditions for these standards     Communications cycle    Unit type Product Name in DC Mode  1    2  EtherCAT Coupler Unit  NX Series 250 to 4 000 us  EtherCAT Coupler    Unit             Current  consumption    1 45 W or lower       125 to 10 000 us 1 25 W or lower    Maximum I O  power supply  current       Model Standards  NX ECC201  UC1  N  L   CE  KC  NX ECC202  NX ECC203 UC1  CE  KC        1  This depends on the specifications of the EtherCAT master  For example  the values are as follows when the EtherCAT Coupler Unit is  connected to the built in EtherCAT port on an NJ5 series CPU Unit  500 us  1 000 us  2 000 us  and 4 000 us  Refer to the NU NX series CPU  Unit Built in EtherCAT Port User   s Manual  Cat  No  W505  for the specifications of the built in EtherCAT ports on NJ NX series CPU Units      2  This depends on the Unit configuration     Recommended EtherCAT Communications Cables  Use Straight STP  shielded twisted pair  cable of category 5 or higher with double shielding  braiding and aluminum foil tape  for EtherCAT     Cable with Connectors    Item
2.   Input  256 bytes  Output  256 bytes       Mailbox    Emergency messages and SDO requests       Refreshing methods 7    Node address setting range    I O jitter performance    e Free Run refreshing   e Synchronous I O refreshing   e Time stamp refreshing   e Task period prioritized  refreshing    e Free Run refreshing  e Synchronous I O refreshing  e Time stamp refreshing       When Connected to the Built in EtherCAT Port on an NX series CPU Unit  e Set on switches  1 to 199  e Set with the Sysmac Studio  1 to 512    When Connected to the Built in EtherCAT Port on an NJ series CPU Unit  e Set on switches  1 to 192  e Set with the Sysmac Studio  1 to 192    Inputs  1 us max   Outputs  1 us max                             Communications cycle in DC Mode 250 to 4 000 us     4 125 to 10 000 us    4  Power supply voltage 24 VDC  20 4 to 28 8 VDC     10 W max   ax Unit SEMEN capacity Refer to Installation orientation and restrictions for details   Unit power NX Unit Iv effici 70   supply nit power supply efficiency o  Isolation method No isolation between NX Unit power supply and Unit power supply terminals  Current capacity of power supply IA mar  terminals  Power supply voltage 5 to 24 VDC  4 5 to 28 8 VDC      I O power Maximum I O power supply current 10A  supply z  Current capacity of power supply AAi i   Amax   terminals  NX Unit power consumption 1 45 W max  1 25 W max     Current consumption from I O power supply    Dielectric strength    Insulation resistance     1  Refer
3.  12 0 25   24  PZ6 Roto  0 14 to 6 mm   AWG 26 to 10     terminals  H0 34 12 0 34   22     H0 5 14 0 5   20   HO   HO 5 16  HO  ete o 0 75   18      1  Some AWG 14 wires exceed 2 0 Hs and cannot be used in the screwless clamping terminal block        When you use any ferrules other than those in the above table  crimp them to the twisted wires so that the following processed dimensions are achieved         mm    1 6 mm max     Terminals other than ground terminals    2 0 mm max  2 4 mm max     Ground terminals   Terminals other than ground terminals     2 7 mm max    Ground terminals     Using Twisted Wires Solid Wires  If you use the twisted wires or the solid wires  use the following table to determine the correct wire specifications     Terminals LURES Conductor length  Twisted wires   Solidwire   apona engi   Classification  Bama aa  Possible      Greater than Possible  All terminals except ee des    0 08 to 1 5 mm   ground terminals 2 NANOS OT IESS Not l Not     AWG28 to 16 So IO mm  Greater than Possible   Possible Km Possible    A  4 Peas       1 Secure wires to the screwless ees terminal block  Refer to the Securing Wires in the USER S MANUAL for how to secure wires    2 With the NX TBLILIL 1 Terminal Block  use twisted wires to connect the ground terminal  Do not use a solid wire     SE SSN  PESAN    Conductor length  stripping length            lt Additional Information gt  If more than 2 A will flow on the wires  use plated wires or use ferrules     OMRON       NX 
4.  Appearance    Standard type   Cable with Connectors on Both Ends  RJ45 RJ45    Wire Gauge and Number of Pairs  AWG27  4 pair Cable  Cable Sheath material  LSZH      Cable color  Yellow  3    manufacturer    Recommended    Cable length m        Model    XS6W 6LSZH8SS30CM Y       0 3  0 5    XS6W 6LSZH8SS50CM Y       XS6W 6LSZH8SS100CM Y  XS6W 6LSZH8SS200CM Y  XS6W 6LSZH8SS300CM Y  XS6W 6LSZH8SS500CM Y       Rugged type  Cable with Connectors on Both Ends  RJ45 RJ45   Wire Gauge and Number of Pairs  AWG22  2 pair Cable    XS5W T421 AMD K       XS5W T421 BMD K       XS5W T421 CMD K  XS5W T421 DMD K  XS5W T421 GMD K       Rugged type   Cable with Connectors on Both Ends  M12 Straight   RJ45    Wire Gauge and Number of Pairs  AWG22  2 pair Cable       10 XS5W T421 JMD K  0 3 XS5W T421 AMC K  0 5 XS5W T421 BMC K       XS5W T421 CMC K  XS5W T421 DMC K  XS5W T421 GMC K       Rugged type   Cable with Connectors on Both Ends  M12 Right angle   RJ45    Wire Gauge and Number of Pairs  AWG22  2 pair Cable             10 XS5W T421 JMC K  0 3 XS5W T422 AMC K  0 5 XS5W T422 BMC K        1 Standard type cables length 0 2  0 3  0 5  1  1 5  2  3  5  7 5  10  15 and 20m are available   Rugged type cables length 0 3  0 5  1  2  3  5  10 and 15m are available    2 The lineup features Low Smoke Zero Halogen cables for in cabinet use and PUR cables for out of cabinet use      3 Cables colors are available in blue  yellow  or Green  Note  For details  refer to Cat No G019     XS5W T422 CMC K  XS5W 
5.  EtherCAT Coupler Unit and NX Units   and  Ether CAT Slave Terminals   information on hardware  setup  and functions to set  up  control  and monitor NX Units through EtherCAT           OMRON       Terms and Conditions Agreement    Read and understand this catalog   Please read and understand this catalog before purchasing the products  Please consult your OMRON representative if you    have any questions or comments     Warranties     a  Exclusive Warranty  Omron   s exclusive warranty is that the Products will be free from defects in materials and workmanship  for a period of twelve months from the date of sale by Omron  or such other period expressed in writing by Omron   Omron  disclaims all other warranties  express or implied     b  Limitations  OMRON MAKES NO WARRANTY OR REPRESENTATION  EXPRESS OR IMPLIED  ABOUT  NON INFRINGEMENT  MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS  BUYER  ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE   PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE    Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the  Products or otherwise of any intellectual property right   c  Buyer Remedy  Omron   s sole obligation hereunder shall be  at  Omron   s election  to  i  replace  in the form originally shipped with Buyer responsible for labor charges for removal or  replacement thereof  the non complying Product   ii  repair the non complying 
6.  to the NX series Safety Control Units User   s Manual  Cat  No  Z930  for the number of Safety Control Units that can be connected     2  This function was added or improved for a version upgrade  Refer to NX series EtherCAT Coupler Unit User s Manual  Cat  No  W519  for  information on version upgrades    3  This depends on the specifications of the EtherCAT master  The values are as follows when you are connected to the built in EtherCAT port  on an NJ5 series CPU Unit  500 us  1 000 us  2 000 us  and 4 000 us  Refer to the NU NX series CPU Unit Built in EtherCAT Port User s  Manual  Cat  No  W505  for the specifications of the built in EtherCAT ports on NJ NX series CPU Units     4  This depends on the Unit configuration     5  Use an output voltage that is appropriate for the I O circuits of the NX Units and the connected external devices     10 mA max   for 24 VDC   510 VAC for 1 min  leakage current  5 mA max   between isolated circuits   100 VDC  20 MQ min   between isolated circuits     OMRON       Item    External connection terminals    Dimensions  Weight    NX ECC    Specification  NX ECC201 NX ECC202 NX ECC203    Communications Connector   For EtherCAT communications    e RJ45 x 2  shielded    e IN  EtherCAT input data  OUT  EtherCAT output data    Screwless Clamping Terminal Block  For Unit power supply  I O power supply  and grounding  Removable     Peripheral USB Port   For Sysmac Studio connection    e Physical layer  USB 2 0 compliant  B type connector  e Tr
7. Companies shall not be responsible for conformity with any standards  codes or regulations which apply to the    combination of the Product in the Buyer   s application or use of the Product  At Buyer   s request  Omron will provide applicable  third party certification documents identifying ratings and limitations of use which apply to the Product  This information by itself  is not sufficient for a complete determination of the suitability of the Product in combination with the end product  machine   system  or other application or use  Buyer shall be solely responsible for determining appropriateness of the particular Product  with respect to Buyer   s application  product or system  Buyer shall take application responsibility in all cases    NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE  QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS   AND THAT THE OMRON PRODUCT S  IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE  OVERALL EQUIPMENT OR SYSTEM     Programmable Products   Omron Companies shall not be responsible for the user   s programming of a programmable Product  or any consequence    thereof     Performance Data    Data presented in Omron Company websites  catalogs and other materials is provided as a guide for the user in determining  suitability and does not constitute a warranty  It may represent the result of Omron   s test conditions  and the user must co
8. ECC    Dimensions  Unit  mm     EtherCAT Coupler Unit    EtherCAT Coupler Unit Only                                                                                                                         y A         104 5  100  A  O  Y AA  A  1 5 65 2  gt    __  0 55  71     80      The dimension is 1 35 mm for Units with lot numbers through December 2014       With Cables Connected    a x1             i 100 to 120  2    71  5 8                                     OOOO  TOD USB cable  JOTO  HHH  HHA                                                       Communications cable           1  This dimension depends on the specifications of the commercially available USB cable  Check the specifications of the USB cable that is used    2  This is the dimension from the back of the Unit to the communications cables    e 100 mm  When an MPS588 C Connector is used    e 120 mm  When an XS6G T421 1 Connector is used     OMRON       NX ECC    End Cover                                                                                                                                                This is the shape for Units with lot numbers through December 2014     Related Manuals    Man  No   Model Manual Application Description    The following items are described  the overall  Leaning how to use an system and configuration methods of an EtherCAT  W519 NX ECC200 NX series EtherCAT NX series EtherCAT Slave Terminal  which consists of an NX series  Coupler Unit User s Manual   Coupler Unit and
9. Ground to 100 Q or less  0 to 55  C  10  to 95   with no condensation or icing        Atmosphere    Must be free from corrosive gases        Ambient storage temperature       25 to 70  C  with no condensation or icing        Altitude    2 000 m max        Pollution degree  Noise immunity    Pollution degree 2 or less  Conforms to JIS B3502 and IEC 61131 2   Conforms to IEC61000 4 4  2 kV  power supply line        Overvoltage category  EMC immunity level    Category Il  Conforms to JIS B3502 and IEC 61131 2   Zone B          Vibration resistance    Shock resistance    Applicable standards      Conforms to IEC 60068 2 6   5 to 8 4 Hz with 3 5 mm amplitude  8 4 to 150 Hz  acceleration of 9 8 m s   100 min each in X  Y  and Z  directions  10 sweeps of 10 min each   100 min total     Conforms to IEC 60068 2 27  147 m s   3 times each in X  Y  and Z directions    cULus  Listed UL508 and ANSI ISA 12 12 01  EC  EN 61131 2 and C Tick  KC Registration  NK  LR      Refer to the OMRON website  http   www ia omron com   or consult your OMRON representative for the most recent applicable standards for    each model     Specifications  EtherCAT Coupler Unit NX ECC201 NX ECC202 NX ECC203    Item    Number of connectable NX Units    NX ECC201 NX ECC202    Specification  NX ECC203  63 Units max          Send receive PDO data sizes    Mailbox data size    Input  1 024 bytes max   including input data  status  and unused areas   Output  1 024 bytes max   including output data and unused areas   
10. NX series EtherCAT Coupler Unit    NX ECC    Combine flexibility in Remote I O configuration  with the speed and determinism of EtherCAT        CSM_NX ECC_DS_E_7_1    e The EtherCAT Coupler Unit is the link between the EtherCAT Machine  Control network and the NX series I O Units  With I O Units ranging from  basic I O s to high speed synchronous models  the NX series is the perfect  match for the Sysmac Machine Automation Controllers        Features    e Up to 63 NX IO Units can be connected to one EtherCAT Coupler Unit  Standard and high performance units can be mixed       e High speed remote I O control is possible at the fastest communication cycle of 125 us      e Each Coupler plus its I O form just a single EtherCAT node on the network    e   O control and safety control can be integrated by connecting Units for safety    e The Coupler supports the EtherCAT Distributed Clock  DC  and propagates this to synchronous I O units    e The node address can be fixed by rotary switches  or set by software  Choose the method that best suits your way of engineering    e Slave configuration by Sysmac Studio can be done centrally via the controller  or on the spot using the Coupler s built in USB port      1 Input per Coupler Unit  Maximum 1024 bytes  Output per Coupler Unit  Maximum 1024 bytes   2 NX7 LILILILI and NX ECC203 combined    System Configuration    Sysmac Studio  Support Software EtherCAT master   NJ NX series CPU Unit or master from  l l another manufacturer  Connectio
11. Product  or  iii  repay or credit Buyer an amount  equal to the purchase price of the non complying Product  provided that in no event shall Omron be responsible for warranty   repair  indemnity or any other claims or expenses regarding the Products unless Omron   s analysis confirms that the Products  were properly handled  stored  installed and maintained and not subject to contamination  abuse  misuse or inappropriate  modification  Return of any Products by Buyer must be approved in writing by Omron before shipment  Omron Companies shall  not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or  electronic components  circuits  system assemblies or any other materials or substances or environments  Any advice   recommendations or information given orally or in writing  are not to be construed as an amendment or addition to the above  warranty    See http   www omron com global  or contact your Omron representative for published information     Limitation on Liability  Etc   OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL  INDIRECT  INCIDENTAL  OR CONSEQUENTIAL DAMAGES     LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS   WHETHER SUCH CLAIM IS BASED IN CONTRACT  WARRANTY  NEGLIGENCE OR STRICT LIABILITY   Further  in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted     Suitability of Use   Omron 
12. T422 DMC K  XS5W T422 GMC K  XS5W T422 JMC K    OMRON       NX ECC    Cables   Connectors  Wire Gauge and Number of Pairs  AWG24  4 pair Cable          Item Appearance Recommended manufacturer Model    Hitachi Metals  Ltd  NETSTAR C5E SAB 0 5 x 4P   Cables   Kuramo Electric Co  KETH SB     SWCC Showa Cable Systems Co  FAE 5004   RJ45 Connectors   Panduit Corporation MPS588 C          We recommend you to use above cable and connector together   Wire Gauge and Number of Pairs  AWG22  2 pair Cable    Item Appearance Recommended manufacturer Model    Kuramo Electric Co  KETH PSB OMR   Cables      Nihon Electric Wire amp Cable Co  Ltd  PNET B        RJ45 Assembly    XS6G T421 1   Connector            We recommend you to use above cable and connector together   Note  Connect both ends of cable shielded wires to the connector hoods     Optional Products    Product name Specification Model Standards    Pins for 10 Units NX AUX02    Semone ech Coding Ens  30 terminal block pins and 30 Unit pins     Specification             Product Name   Model Standards  No  of terminals Ground terminal mark i a  Accessories    End Cover  NX END01     An End Cover is connected to the end of the EtherCAT Slave Terminal   One End Cover is provided together with the EtherCAT Coupler Unit     OMRON       General Specification    Enclosure    Item    NX ECC    Specification  Mounted in a panel       Grounding method    Operating  environment    Ambient operating temperature  Ambient operating humidity    
13. ansmission distance  5 m max     46 x 100 x 71 mm  WxHxD   170 g max              Installation orientation and restrictions    Circuit layout    Installation orientation  6 possible orientations  Restrictions     Used in the upright installation orientation     10 W output  40  C    Output power  W   12    10 8 5 W output  55  C       0 10 20 30 40 45 50 55 60  Ambient temperature    C   Used in another orientation other than the upright installation orientation      0   Output power  W  10 W output  40  C    6 0 W output  55  C       Peripheral   USB port   Internal  IN communications circuits  connector    OUT communications O        connector es  a aan NX Unit    Non isolated power supply    UG power supply  NX Unit NX bus  UG ly    Terminal power supply connector  ermina IOV J    block   O power  supply    OS I O power  I O PWR LED supply         D3    O DIN Track contact plate       OMRON       NX ECC    Specification  NX ECC201 NX ECC202 NX ECC203       Item    A1 B1    D Through wiring  molu He for unwired  Unit power supply terminals     I   l   oo    24 VDC  i  l   I             Terminal arrangement       O power supply   5 to 24 VDC     Ground to 100Q  or less    Accessory End Cover  NX END0O1   1    EtherCAT Communications Specifications       Item Specification  Communications standard IEC 61158 Type 12  Physical layer 100BASE TX  IEEE 802 3   Modulation Baseband  Baud rate 100 Mbps  Topology Depends on the specifications of the EtherCAT master        Category 5 o
14. ed to connect each Unit    B  Indicators The indicators show the current operating status of the Unit    C  Gorimunicaions connectors These connectors are connected to the communications cables of the EtherCAT network   There are two connectors  one for the input port and one for the output port    D  Peripheral USB port This port is used to connect to the Sysmac Studio Support Software    E  Temna block The terminal block is used to connect external devices   The number of terminals depends on the type of Unit    F  Rotar sniiches These rotary switches are used to set the 1s digit and 10s digit of the node address of the EtherCAT Coupler  y Unit as an EtherCAT slave  The address is set in decimal    G  DIP switch The DIP switch is used to set the 100s digit of the node address of the EtherCAT Coupler Unit as an EtherCAT       Terminal Block    NX TBC082                            A                                        WW   lt                                    a                                                                                                                                                                      Eight terminal Block          slave           Symbol Name Function  The terminal numbers  A1 to A8 and B1 to B8  are displayed    A  Terminal number indications The terminal number indicators are the same regardless of the number of terminals on the terminal block  as  shown above    B  Release holes Insert a flat blade screwdriver into these holes to c
15. n to peripheral USB port or       built in EtherNet IP    port on       NJ NX series CPU Unit                         WZ    Built in EtherCAT port                                                                                                                                                                                                                                                          Sysmac Studio  EtherCAT Slave Terminal  Support Software Communications cable    0 2000    Ethernet cables    NX Series l i        EtherCAT Coupler Unit  l      gt  Peripheral USB port  l UEC CENE i  AX M M  A 3  l  l l  l  Connection to peripheral USB i l    port on EtherCAT Coupler Unit E i  l   xml I           I    ESI files NX Units End Cover i      Refer to Versions information on the unit versions of CPU Units when you connect an EtherCAT Slave Terminal to the built in EtherCAT port on  an OMRON NJ NX series CPU Unit  An EtherCAT Slave Terminal cannot be connected to any of the OMRON CJ1W NCLJI_J81 LILJ82 Position  Control Units even though they can operate as EtherCAT masters     Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products   EtherCAT   is a registered trademark of Beckhoff Automation GmbH for their patented technology    EtherNet IP    is the trademarks of ODVA    Other company names and product names in this document are the trademarks or registered trademarks of their respective companies  
16. onnect and remove the wires    C  Terminal holes The wires are inserted into these holes           Ground terminal mark       This mark indicates the ground terminals  Only the NX TBC082 has this mark     Applicable Terminal Blocks for Each Unit Model    Unit model  Unit power supply  NX ECC201 4A  NX ECC202 or 4A  NX ECC203       Current capacity of  Unit s power supply terminals    Terminal Blocks            Ground terminal Terminal current  I O power supply Model No  of terminals ark capacity  NX TBC082 8 Present 10A  10A NX TBC082 8 Present 10A    OMRON       NX ECC    Applicable Wires    Using Ferrules   If you use ferrules  attach the twisted wires to them    Observe the application instructions for your ferrules for the wire stripping length when attaching ferrules   Always use plated one pin ferrules  Do not use unplated ferrules or two pin ferrules     The applicable ferrules  wires  and crimping tool are given in the following table       Applicable wire N  Terminal types   Manufacturer Ferrule model  mm   AWG   Crimping tool    Terminals other   Phoenix Al0 34 8 0 34   22  aes Contact  The figure in parentheses is the applicable wire    than ground Contact Al0 5 8 0 5   20  size    terminals oss Joswen   CRIMPFOX 6  0 25 to 6 mm   AWG 24 to 10     Al0 5 10    a    Al1 5 8 1 5   16   Al1 5 10  Ground Al2 5 10 2 0     terminals    Terminals other   Weidmuller H0 14 12 0 14   26  Weidmueller  The figure in parentheses is the applicable wire size      than ground H0 25
17. r higher twisted pair cable  Recommended cable  double shielded cable    Transmissionimedia with aluminum tape and braiding        Transmission distance Distance between nodes  100 m or less    Version Information                      Corresponding unit version version       Mogel Pa Unit version Using an NX series CPU Unit Using an NJ series CPU Unit  Unit version of CPU Unit   Sysmac Studio version   Unit version of CPU Unit   Sysmac Studio version  1 2 Ver  1 07 or later Ver  1 08 or higher  NX ECC201 1 1 Ver  1 06 or later Ver  1 07 or higher  1 0 Ver  1 10 or later Ver  1 13 or later Ver  1 05 or later Ver  1 06 or higher  NX ECC202 12   Ver  1 07 or later Ver  1 08 or higher  NX ECC203 ales Ver  1 07 or later Ver  1 13 or higher              1 Some Units do not have all of the versions given in the above table  If a Unit does not have the specified version  support is provided by the  oldest available version after the specified version  Refer to the user s manuals for the specific Units for the relation between models and  versions     2 For the NX ECC202  there is no unit version of 1 1 or earlier     3 For the NX ECC2038  there is no unit version of 1 2 or earlier     OMRON       External Interface    EtherCAT Coupler Unit NX ECC20 1                 NX ECC                A  1    l      tl          j    ODORO Gf  OROROPORONOPOROBL     O  Q       aa                                                           Symbol Name Function   A  NX bus connector This connector is us
18. rrelate  it to actual application requirements  Actual performance is subject to the Omron   s Warranty and Limitations of Liability     Change in Specifications   Product specifications and accessories may be changed at any time based on improvements and other reasons  It is our    practice to change part numbers when published ratings or features are changed  or when significant construction changes are  made  However  some specifications of the Product may be changed without any notice  When in doubt  special part numbers  may be assigned to fix or establish key specifications for your application  Please consult with your Omron   s representative at  any time to confirm actual specifications of purchased Product     Errors and Omissions   Information presented by Omron Companies has been checked and is believed to be accurate  however  no responsibility is  assumed for clerical  typographical or proofreading errors or omissions     2015 6  In the interest of product improvement  specifications are subject to change without notice     OMRON Corporation    Industrial Automation Company    http   www ia omron com    c Copyright OMRON Corporation 2015 All Right Reserved     
    
Download Pdf Manuals
 
 
    