1. MW t Ei RED GROUND HEATING ELEMENTS d d Lo TL TU CONNECTPOWER SUPPLY HERE 240V Ld 25 SteamSpa PHONE 516 986 5325 FAX 866 560 5662 http steamspa com info steamspa com INSTALLATION amp USER GUIDE
2. Control panel outside room ve p ATTENTION The illustration is just an example the practical installation must comply with the nation s electrical criteria and be done by a professional electrician SteamSpa PHONE 516 986 5325 FAX 866 560 5662 http steamspa com info steamspa com Page 5 INSTALLATION amp USER GUIDE amSpa Zw PLUMBING INSTALLATION WARNING The installation of all water supply lines should be in accordance to all national and local codes by a licensed plumber 1 Use unions when connecting pipes 2 Use brass pipes or copper hoses only 3 Do not use black and galvanized or PVC pipes WATER SUPPLY PIPE 1 2 Connect hot water or cold water pipes The Industry recommends the use of a hot water line However it should not exceed 160 F Install stop valve in the water supply line The stop valve should be installed in a place where it is easily accessible in case of an emergency Flush the water supply line completely before connecting the water pipe to the steam generator to remove any sediments in the water The water pressure should be at best between 15 and 20 Ibs square inch If necessary decrease the pressure accordingly If necessary install a Hydro pneumatic device which reduces pressure spikes 2 3 4 5 STEAM 3 4 1 Do not install any stop valves in the steam pipes The steam can never be obstructed 2 Install a copper pipe of 3 4 inch as the steam pi
3. Fill water valve A Form 1211 G Control Panel Red ShortPin OIOIO Black LongPin Terminal Block Yellow MiddlePin OIOI LN E Red J1 2 Red Black 1 1 Black Black J2 1 Black V A V A S gt 5 Supply ee gt a og e E peas Water Level Sensor To Control Panel L2 Li Red ShortPin Black LongPin Yellow MiddlePin hr hr Yellow Green Black J1 1 Black J2 1 V A Fill water valve 2 S750 S900 Ld Page 11 SteamSpa PHONE 516 986 5325 FAX 866 560 5662 http steamspa com info steamspa com INSTALLATION amp USER GUIDE Jl 1 Black Black V A V A O gt 9 ed ed gt gt 8 8 E f MM ee L2 LI G No ox Water Sensor To Control Panel 1 1 But on PAL 9 Q 1 Q ki Terminal Block Yellow MiddlePin IO I O Yellow Green Jl 1 Black V Black Fill water valve INSTALLATION OF THE TOP LIGHT CAUTION The power of the light should not surpass 3 watts rated power to prevent the damage of the transformer 1 A whole set is equipped with AC 12V 3 watt LED lamp 2 The light should be installed on the ceiling of the steam room or in a location not accessible to children CAUTION Installer must take some moisture proof measures in the process of installation Electrophorus components cannot be exposed to moisture as it w
4. 516 986 5325 FAX 866 560 5662 http steamspa com info steamspa com INSTALLATION amp USER GUIDE TROUBLESHOOTING Replace fuse 0 8A 240V Burned out fused Cut power Supply and reconnect The electrical wiring became loose wiring Control panel connection loose Reconnect control panel and reset Controller turn off and on Check whether the wire connector is dampened or damaged and dry if dampened Replace heating element The machine does not start when powered The wire connector is dampened or Breakers are tripping damaged Damaged heating element 1 Check whether the connection plug The control panel wire is not between the control panel and the The display screen on the control panel connected properly generator has become loose and does not display anything Trouble with generator whether the power circuitry has motherboard good contact Replace the motherboard The water pipe connector becomes 1 Tighten the loose connection or Water leakage loose or pipe is broken change the broken pipe 9 Water leakage in the water input Change the water input valve or the valve or the water drainage valve water drainage valve Check the power supply and No electricity connections No water Check the water input pipe and water The set temperature is too low input valve Wiring connection problem Reset the temperature Check wiring connection and tighten No steam when starting the machine The steam
5. STEP FIVE Remove the adhesive paper from Control Panel To achieve proper adhesion make sure surface clean dry and free of dust IMPORTANT Do not over extend or clip control panel wire as it may cause possible damage STEP SIX Run a bead of silicone around adhesive gasket Press Control Panel against wall at a 12 O clock position until firmly adhered to surface IMPORTANT Please do not apply an excessive amount of silicone Just enough to provide a moisture seal should suffice Page 15 SteamSpa PHONE 516 986 5325 FAX 866 560 5662 http steamspa com info steamspa com INSTALLATION amp USER GUIDE TESTING THE MACHINE 1 Make sure the power switch of the control panel is turned on the control panel displays and the water supply valve will open Press the steam switch the control panel will display the temperature of the environment the steam engine begins to input water to start the steam function and while opening the steam press the button to open light function When there is steam output press again the steam will stop and the light will go off automatically Press the button to start the steam the steam will come out of the steam generator in no more than 1 minute Afterwards the steam generator will supply water about every minute the steam will decrease but not stop and about 10 seconds later the steam will come out normally As time goes on the temperature displayed in the control p
6. does not come out the water 1 Cut power supply and check sounds in the machine 1 Possible steam pipe blockage blockage in steam pipe 1 Bad LED light bulb 1 Change LED light bulb Light doesn t turn on 2 Wiring connection improperly 2 Tighten connection or replace light connected or light cable damage cable Page 19 SteamSpa PHONE 516 986 5325 FAX 866 560 5662 http steamspa com info steamspa com INSTALLATION amp USER GUIDE TECHNICAL PARAMETERS Tye 45KW 6KW 7 5KW 9KW 10 5KW 12KW 15KW PowrKW 45 6 75 9 105 12 15 Vote 20 240 20 20 20 20 20 3 4 9 639 t 1 40 44 90 4 5 5 5 StamVo cuin mm 9 13 16 9 a 25 WaterVol ou in 80 160 160 10 30 50 59 00 90 Applicable Space of the Wed o m zs x a wo IMPORTANT The list above is for reference only Actual checking and repairing should be based on national and local codes ask professional service personnel to operate IMPORTANT The parameter listed above will vary by geographical location and environment Please consult a qualified designer and architect for more detailed use 15 240 63 9 29 30 00 Page 20 SteamSpa PHONE 516 986 5325 FAX 866 560 5662 http steamspa com info steamspa com INSTALLATION amp USER GUIDE Bringing the Spa toYou y WIRING DIAGRAMS 4 5KW Control panel outside room Control panel inside room seb HFU
7. Bringing the Spa toYou P STEAM BATH GENERATOR USER GUIDE Steam Spa PHONE 516 986 5325 FAX 866 560 5662 http steamspa com infoGsteamspa com TABLE OF CONTENTS PROLOGUE 3 USER STRUCTION d 3 CHOOSING THE RIGHT LOCATION 22 2 2 3 INSTALLATION DRAWING OF STEAM GENERATOR 4 PLUMBING INSTALLATION 6 STEAM GENERATOR SPECIFICATIONS 1 6 ELECTRICAL REQUIREMENTS ee ae 9 ASSEMBLY GRAPH FOR POWER 2 2 1 10 INSTALLATION OF THE TOP LIGHT nnee 12 STEAM GENERATOR DISSECTION DIAGRANM 13 CARE amp USE FOR THE CONTROL PANEL 14 CONTROLLER BOX CONTENT 4 4 2 2 1 14 CONTROL PANEL INSTALLATION INSTRUCTIONS eee 15 TESTING THE MACHINE P aa 16 CONTROL PANEL DIAGRAM U l aa a kot aa anaa E too ei aa 16 CONTROL PANEL OPERATION err
8. ION INSTRUCTIONS STEP ONE Determine the installation location of the control panel The master control panel is designed to be installed in the steam room only please install 1 4 5 feet from the ground 2 Away from the steam head and do not expose under the direct spray of steam 3 Install in the perpendicular wall 4 The position of installation should facilitate easy operation and convenient wiring The controller wire is 1 6 feet long with a controller lengthen wire of 20 feet max The installation of the controller should be in a position not more than 25 feet from the steam generator STEP TWO Drill a round hole of 1 inch in diameter in a chosen position STEP THREE Pull control panel wire inside steam room through opening connect it to the lengthened wire and then to the steam generator and connect with the corresponding wire in the generator Connecting the wire of control panel outside room to the wire of control panel inside the room When connecting wires please follow arrows on connector heads for proper connection Failure to do so will result in damaging of control pins STEP FOUR Start the power supply of steam generator check and adjust connection check each item on the page to make sure all functions work well Control panel outside room Control panel inside room IMPORTANT Before adjusting the control panel make sure the steam generator is shut off otherwise the control panel may get damaged
9. SE RED EBE GROUND HEATING ELEMENTS T i DL 12 CONNECT POWER SUPPLY HERE 240V 21 SteamSpa PHONE 516 986 5325 FAX 866 560 5662 http steamspa com info steamspa com INSTALLATION amp USER GUIDE Bringing the Spa toYou 5 p d 6KW Control panel outside room Control panel inside room 4 gt ofo TEMPERATURE SENSOR M seb GROUND HEATING ELEMENTS CONNECT POWER SUPPLY HERE 240V Page 22 SteamSpa PHONE 516 986 5325 FAX 866 560 5662 http steamspa com info steamspa com INSTALLATION amp USER GUIDE 15 N SpatoYou 5 p d 7 5 8 9KW Control panel outside room Control panel inside room T 1 the INSTALLATION amp USER GUIDE GROUND HEATING ELEMENTS 1 TD CONNECT POWER SUPPLY HERE 240V Page 23 SteamSpa PHONE 516 986 5325 FAX 866 560 5662 http steamspa com info steamspa com Bringing the Spa toYou S p d 10 5KW 8 12KW Control panel outside room Control panel inside room 2 BRITEN HEATING ELEMENTS d j CONNECT POWER SUPPLY HERE 240V Page 24 SteamSpa PHONE 516 986 5325 FAX 866 560 5662 http steamspa com info steamspa com INSTALLATION amp USER GUIDE 15KW Bringing the Spa toYou p y Control panel outside room Control panel inside room ofo TEMPERATURE SENSOR aa
10. anel will rise with the temperature in the room before it stops and stays at the set temperature 5 Based on different requirements of the user for temperature and steam time the control panel can adjust temperature and Steam time While testing the machine set the time to be 30 minutes and the temperature to be 120F 6 When the set steam time Is due the system will shut off the steam and light function automatically to stop water input and Steam production 7 10 minutes after the steam is shut off the system will start drainage automatically for 7 minutes After testing the machine and it is working properly Then the machine can be operated normally Pc N WARNING Do not dismantle the safety pressure decrease valve arbitrarily IMPORTANT Do not switch the water input pipe when the steam generator is working CONTROL PANEL DIAGRAM 1 POWER ON OFF 6 MEMORY 2 TIME TEMP SET 7 DIGITAL DISPLAY SCREEN 9 TIME TEMP DECREASE 6 STEAMSPA LOG 4 TIME TEMP INCREASE 9 FRONT DECORATIVE BEZEL 9 LIGHT ON OFF 10 TEMP SENSOR Page 16 SteamSpa PHONE 516 986 5325 FAX 866 560 5662 http steamspa com infoGsteamspa com INSTALLATION amp USER GUIDE CONTROL PANEL OPERATION The control panel has a digital temperature control system which can start stop or pause in the preset time to keep the temperature at the set number ON OFF When system is powered all functions will still not be activated and remain in a waiting state D
11. applying glue so that no steam will enter the holes in the wall Page 6 SteamSpa PHONE 516 986 5325 FAX 866 560 5662 http steamspa com info steamspa com INSTALLATION amp USER GUIDE amSpa Zw If non heat resistant material like m acrylic is used as building material Airproof green material belt 4 ds reserve a gap no smaller than 1 4 and fill with heat insulated material x m N Use airproof silica gel or corresponding airproof material to fill the gaps in the wall to achieve the water proof and damp proof effect HU nside wall in the steam room DRAINPIPE 1 2 ACCORDING TO THE NATIONAL AND LOCAL PLUMBING CODES The steam generator drain valve should be equipped with a drainpipe The steam generator drains the water by using gravity and pitch is required Check local code requirements for drain valves Do not connect the safety valve or steam line to drain line SAFETY VALVE 3 4 Safety valve is an automatic system that is actuated by pressure in order to prevent steam pressure increasing in the interior of the generator pressure limit range of the safety valve is 15 PSI and the pressure will begin to decrease if pressure should come over this Value If it is allowed by local codes provide the safety valve with exterior drainpipe Do not dismantle the pressure relief valve while generator is in operation To maintain the p
12. ator Any damages to packaging should be reported immediately to shipping company delivery representative and SteamSpas Customer Service Dept Check model and accessories are correct including voltage input Any discrepancies are to be reported to SteamSpa s Customer Service Dept within 48 hours of delivery Read installation instructions in detail for a secure and effective installation of SteamSpa generators Steam5pa recommends the use of a licensed plumber and electrician for proper installation of SteamSpa generators oteamopa shall not be responsible for product damage or malfunction caused by self installation or installation procedures which do not comply with user manual steamSpa generators are for indoor use only CHOOSING THE RIGHT LOCATION 1 4 the steam room should be less than 20ft the standard pipe which links the controller and the steam generator should be 20ft The steam generator should not be installed in the steam room Do not install outdoor or in any places that will influence the performance of the machine by the environment Do not install in a frigid location or any places where the water will freeze Do not install near flammable chemicals Install in a dry place where the ventilation is good Install an exhaust fan outside of the steam room for the excess steam to be expelled from the shower room The steam generator has a hanging groove for wall installations Both sides and the top of the steam gener
13. ator need to reserve at least 12 inches space 10 The area where the machine is installed must be easily cleaned up and convenient for the disassembly of the machine 11 The installation area must be convenient for the steam generator draining system 12 he steam tube safety valve drain valve water tube and steam outlet remain very heated after the steam generator has stopped working for some time 13 The controller must be installed in the steam room opposite to the steam head please read the instructions for the controller s installation and operation N co co NO Go Page 3 SteamSpa PHONE 516 986 5325 FAX 866 560 5662 http steamspa com info steamspa com INSTALLATION amp USER GUIDE INSTALLATION DRAWING OF STEAM GENERATO FR VN V YA YA VA VA VA YA WO A V N N VA YA VA YA Wo ATTENTION The drawin designer architect or bui Rs N N N N N N amSpa Zw g is only for explanation purposes As for practical design of steam room please consult with a qualified der SteamSpa PHONE 516 986 5325 FAX 866 560 5662 http steamspa com info steamspa com INSTALLATION amp USER GUIDE Sp ar Bringing the SpatoYou 3 The steam outlet The spare place under the wash pan possible location The steam generator Control panel inside room 4 1
14. displays the current mode LIGHT FUNCTION When the machine is started press button to turn on off light function When the light is turned on the digital tube will temporarily display L on Fig 6 When the light is turned off the digital tube will temporarily display Larr Fig 7 Screen will turn to display ambient TEMP if no operation is selected in 5 seconds SteamSpa PHONE 516 986 5325 FAX 866 560 5662 http steamspa com infoGsteamspa com Page 17 INSTALLATION amp USER GUIDE STEAM GENERATOR MAINTENANCE IMPORTANT The steam generator automatically performs a water discharge operation after each use 1 N Wait for the completion of automatic water discharge after each time using the steam generator to make sure the water the tank is discharged completely before cutting off power supply There should not be any leakage or damage among the steam generator steam nozzle components and pipes They should be checked and repaired annually Clean the water supply pipes of the steam generator once a year Check all the faucet connections to ensure wether they are tight and not damaged due to overheat Check the sediments accumulated in the water tank and electric heating tube If the sediment is thick dispose of it in time using diluted lemon acid to soak for 15 30 minutes Remove the water level sensory needle once a quarter to clean the sediment in the needle Page 18 SteamSpa PHONE
15. e 17 STEAM GENERATOR WMAINTENANCE nana nn nun anana nanang anae n 18 TECHNICAL PARAMETERS u e m ia u 20 WIRING DIAGRAMS a ee ea ee een 21 Page 2 SteamSpa PHONE 516 986 5325 FAX 866 560 5662 http steamspa com info steamspa com INSTALLATION amp USER GUIDE PROLOGUE Thank You for choosing SteamSpa for health beauty and relaxation Now you can enjoy your own private sanctuary in the comfort ofyour own home Let your stress melt away as you relax in your state of the art Steam Room For Genturies people have recognized the health benefits of saunas Leave your stress behind and enter a world of total relaxation ridding you of pain toxins and sore muscles as well as increasing your blood circulation etc leaving your skin glowing Besides these physical effects a SteamSpa Session will leave you totally relaxed by providing you a peaceful and relaxing environment away from all Our advanced technology engineering and product development provides Steam Generators that enhance the lifestyles of people throughout the world SteamSpa is continuously refining updating and developing their products assuring the optimum quality and performance of their products Working with the industries top engineers we have developed the most efficient dependable and highest quality products USER INSTRUCTIONS 1 Check for visible damages upon delivery of Gener
16. igital tube will display Fig 1 In the waiting state press the button to tu on the system and activate steam function System will recall last use steam time and TEMP system begins to count down During this time the digital tube will display the ambient temperature Steam temperature display range is 32 F 140 F When the actual temperature is lower or equal to 32 F the digital tube will display 32 F When the actual temperature is higher or equal to 140 F the digital tube will display 140 F The last digit displays as the F unit Fig 2 of Fahrenheit temperature The default steam time is 30 minutes When lacking water the heating elements will stop heating and the water inlet valve will work automatically If there is no water detected in 5 seconds or the water coming in does not reach the set point in 15 seconds the digital tube will display EU Fig 3 to indicate an error of not enough water cycling If there is enough water cycling the steam function will return to normal When the steam function is started if the ambient room temperature is higher than the set point the heating element will stop heating the digital tube will flash to display the current environment temperature when the environment temperature is lower than the set point the heating element will work again the digital tube will display current room temperature normally When the system is on press button to turn off the system or when the steam time
17. ill cause damage to the light components causing a possible short circuit Ceiling of steam room LED light SteamSpa PHONE 516 986 5325 FAX 866 560 5662 http steamspa com infoGsteamspa com Page 12 INSTALLATION amp USER GUIDE OO INI ENGLOSURE 7 WATER DRAIN VALVE 13 TERMINAL BLOCK INSULATION BRACKET 8 SUBSIDIARY WATER TANK 14 F CIRCUIT BOARD 9 MAIN WATER TANK 15 GROUND WIRE CONNECTOR STEAM OUTLET 10 HEATING ELEMENT 16 RELAY PRESSURE RELIEF VALVE 11 221 F HI LIMIT 17 WATER LEVEL SENSOR WATER FILL VALVE 12 TRANSFORMER Page 13 SteamSpa PHONE 516 986 5325 FAX 866 560 5662 http steamspa com infoGsteamspa com INSTALLATION amp USER GUIDE CARE 8 USE FOR THE CONTROL PANEL 1 Use soft cloth with a little soap water to clean the control panel 2 Donotuse crude cleaning tools 3 Ifthe decorating facade is damaged contact service electrician to change it Do not install any SteamSpa controls without reading and understanding the SteamSpa generator Installation and Instruction manual Failure to read and understand these instructions will result in inoperative control generator hazardous overheating and or inadequate heating of the steam room Do not route control wiring inside or close to power lines conduit hot water or steam piping Doing so may result in an inoperative control generator and or hazardous installation Do not install SteamSpa controls with other than SteamSpa compa
18. is over the system shuts off 10 minutes after the system is shut off the drainage function will be started automatically for 7 minutes TIME AND TEMPERATURE SETTING When system is on press button twice system will cycle switch in time setting TEMP setting and ambient TEMP display state Fig 4 When the digital tube displays dashes across the screen it will allow you to set the duration of the steam bath During this time press or W to adjust steam time Its range is 1 60 minutes with 1 minute intervals If there is no adjustment in 5 seconds the system will exit time setting automatically and the LED will display current ambient TEMP When the LED screen shows number and TEMP unit F it is displaying the indoor ambient temperature When the TEMP unit F flashes on the LED screen it means the system is in the steam TEMP setting state During this time press or Wto adjust steam TEMP Fig 5 Its range is 50 130 Fahrenheit with 1 increments If no adjustment is done in 5 seconds the system will exit the TEMP setting automatically and the LED screen will display ambient temperature MEMORY FUNCTION When system Is on it recalls the last time used with the steam time and TEMP After adjusting steam time and steam TEMP press M for about 1 5 seconds to adjust time and TEMP parameters as current state The LED screen will show current settings When system is on press Mio switch modes between SET1 and SET2 The LED screen
19. pe between the steam generator and the steam nozzle 3 The heat insulation material used to insulate the steam pipe should be resistant to temperatures as high as 250 F or higher 4 The steam pipe should be installed inclining 1 4 inches to the steam room Do not bend it in a shape to make sure that cooled water will not stay in the curve of the steam pipe 5 The shorter the distance the better Try to decrease the number of elbows to prevent creating valleys or traps STEAM HEAD 3 4 ATTENTION Steam Head and the steam outlet get very hot try to avoid installing the steam head in a position which will easily come into contact with the person bathing 1 Install the steam head 6 inches above the ground and 12 inches from wall If the steam room material is acrylic or non heat resistant sheet please consult with material manufacturer about steam room applications 2 The steam head outlet should be installed face down To prevent scalding bather with steam or water ATTENTION Tighten steam head by hand Do not use a spanner or other tools use a little soap water and soft sponge to wipe and do not use erosive chemical solutions or crude cleaning tools IMPORTANT 1 Please consult manufacturer of materials like acrylic fiber glass or other anti heat sheet about the installation of the steam head 2 Inthe entire steam room it is required that steam does not leak out The pipes its accessories and the holes should be air proof by
20. roper automatic operation of the safety valve make sure the safety valve connection pipe is smooth Aw N Page SteamSpa PHONE 516 986 5325 FAX 866 560 5662 http steamspa com infoGsteamspa com INSTALLATION amp USER GUIDE STEAM GENERATOR SPECIFICATIONS 395mm 304mm 302mm Water drainage 72mm Fuse for wire power supply Controller wire and light wire hole Fuse for wire power supply 370mm 260mm 30mm _lOmm 400mm Fuse for wire power supply Controller wire and light wire hole Power wire hole Fuse for wire power supply Page 8 SteamSpa PHONE 516 986 5325 FAX 866 560 5662 http steamspa com info steamspa com INSTALLATION amp USER GUIDE 234mm L I Steam outlet Safety valve Water inlet 38 5mm 2 3mm Controller wire and Power wire hole 4 light wire hole Fuse for wire power supply 10 5KW 12k W 15k W ATTENTION To facilitate maintenance keep the steam engine clean If the information provided is limited do not operate on the pipeline and electric equipment arbitrarily as shown in the figure for proportion ELECTRICAL REQUIREMENTS ME ti ka SUPPLY CIRCUITRY Test the voltage of the power supply and make sure suitable voltage is used for the steam generator Insulated copper wire should be used with an anti heat temperature of 90 C and a specified voltage of 300V Refer to na
21. tible steam generators Doing so may result in possible generator damage or inoperative installation single Control Panel with Temperature sensor must be installed inside bathing area 5 feet above floor Do not install Control directly above Steam Head or below shower head but rather in the seating area on a vertical wall Doing so may result in improper temperature reading and or inoperable control Dual Control Panel with Temperature sensor in Master Control must be installed inside bathing area 5 feet above floor Do not install Control directly above Steam Head or below shower head but rather in the seating area on a vertical wall Doing so may result in improper temperature reading and or inoperable control Slave Control installation location is designed to be installed outside the steam room Turn power to the steam generator off before connecting the control to the generator Failure to turn the power off generator prior to connecting controls will result in an inoperable control Discontinue use of the steam generator or control if the steam generator is damaged Continue to do so may result in an inoperative or hazardous installation CONTROLLER BOX CONTENT Control panel Steam nozzle User guide Controller lengthen wire 20 feet 113mm 23mm 50mm lt gt 14 SteamSpa PHONE 516 986 5325 FAX 866 560 5662 http steamspa com info steamspa com INSTALLATION amp USER GUIDE CONTROL PANEL INSTALLAT
22. tional or local electricity consumption code for the specifications Refer to the ammeter for the ampere Connect suitably sized equipment grounding wire into the ground terminal All the connections must be in accordance with national and local electricity consumption codes and be installed by professional electricians NO gt ses Page 9 SteamSpa PHONE 516 986 5325 FAX 866 560 5662 http steamspa com info steamspa com INSTALLATION amp USER GUIDE Ampere Meter SHEET The data provided above is for 240V wea dese motors Install an independent circuit breaker between supply line and steam generator Install a power disconnect within sight of steam generator to cut off power when not in use ASSEMBLY GRAPH F R POWER WIRE T lt C Re L2 4 5 15kW 240V 2PH ATTENTION To avoid damage to the equipment do not connect electric current directly to heating elements WARNING This graph is for explanation only For actual installation refer to national and local electricity consumption codes by professional electricians Page 10 SteamSpa PHONE 516 986 5325 FAX 866 560 5662 http steamspa com info steamspa com INSTALLATION amp USER GUIDE Bringing the Spa toYou p WIRING DIAGRAM L2 L G To Control Panel Block H Y Water Level Sensor Red ShortPin Black LongPin Yellow Middle Pin Black J1 1 V A

Download Pdf Manuals

image

Related Search

Related Contents

RAS-24UKHP-E3 / RAS-24UAH-E3 RAS-18UKHP-E3 / RAS  Samsung YP-GS1CB User Manual  Manual de Instrução  Samsung NX-N2 Käyttöopas  取扱説明書 - 東京ガス  Document du maître 2006-2007  User Manual  Flush Mount Systems  Element Electronics ELCHS261 User's Manual  wMISE EN GARDE  

Copyright © All rights reserved.
Failed to retrieve file