1. AUTO FADE the socket of DMX OUT continuously send out DMX 512 signal The socket of DMX IN OUT will also send out DMX OUT signal when no other DMX signal input once it suspects DMX 512 signal of the socket coming from other controllers it will be automatically defined as DMX IN to receive controller s signal STEP 1 In the mod of DMX OUT DMX IN OUT socket receives DMX signal LCD displays The upper row of LCD displays receiving DMX signal from CH001 CH004 the level is 69 95 40 in the mean while LED on DMX IN is lighted it means that now we have DMX IN signal input STEP 2 It is also available to test signal cable is working well or not Insert the one side of the signal cable into DMX OUT socket of DMX Tester the other side is inserted into DMX IN OUT socket of DMX Tester STEP 3 The LCD display as below the lower row is DMX OUT signal the upper row is DMX IN signal If the signal cable is normal the level of DMX OUT and DMX IN will be equal If no DMX signal is received or the level of receiving is different from level of sending it means that signal cable is abnormal 2 2 AUTO FADE 1 Signal channel gt successive multi channels AUTO FADE set up STEP 1 In the mode of DMX OUT press button DMX OUT 1 to go into function of AUTO FADE LCD will displays DMX sending frequency p The said channel current level ___ Current control DMX cha
2. com STEP 1 When you would like to observe DMX OUT signal you can use wave display measure SYNC of TO SCOPE synchronal signal measurement connector and TX ground please refer to picture below STEP 2 For example DMX Tester sent signal CH001 42H DMX IN you can use wave isplay to measure from SYNC of TO SCOPE synchronal signal connector to TX ground you can see the wave as below CH 00 in red circle is the DMX wave of TX ground CH 01 in red circle is the synchronal signal wave of SYNC 2 9 Low power indication STEP 1 When the battery of DMX Tester is in low power the first line of LCD will switch between normal function and BATTER LOW it displays in the mode of DMX OUT STEP 2 Then you can charge DMX Tester otherwise DMX Tester will be in the mode of low power sleeping after 1 minute LCD displays STEP 3 If you would like to operate DMX Tester low power you can press button DMX OUT1 to wake it up to be back to work DMX Tester will be in the mode of low power sleeping after 1 minute User manual DMX Tester Triton Blue Rev Sep 2013 www triton blue com
3. 2 DMX DMX DMX Q HEX IN OUT2 OUT1 JUL G Pan tt ae aT n l Mee QK s z 7 Fe LEVEL LIGHT j i i o CONTRAST 7 fi 7 6 PET 4 x SPEED D h 2 User manual DMX Tester Triton Blue Rev Sep 2013 www triton blue com OMX OUT g 14 13 10 N TO SCOPE 17 5V 10KO 654321654321 T DC 12V O i 11 03 1 LCD display 8 decimal percent alternate button 2 Baterry chrage indicator 9 DMX signal output XLR 5 PIN 3 External power indicator 10 DMX signal input output XLR 5 PIN 4 Level revolving button 11 Synchronal signal output connector 5 FUNCTION OPTION 12 Power supply input DC 12V 1A 6 Play contrast button 13 DMX signal output PHONE JACK RJ11 7 LCD background light turn on button 14 Power switch 2 1 DMX OUT 1 Single channel successive multi channels DMX OUT set up STEP 1 Turn on Power to go to function DMX OUT Or you can press button DMX OUT 1 in other function mode to go to DMX OUT LCD will display DMX sending frequency p The said channel level ____ Current control dmx DMX channel STEP 2 If you need to change the level of current channel you can push the revolving button to make adjustment Up goes to level increase down goes to level decrease CHO002 will output 10 STEP 4 If you need to control successive multi channels in the same time you choose initial channel you require then press button LCD di
4. TESTER DMX MANUAL DE USARIO USER MANUAL DMX TESTER DMX DMX OUT2 OUT1 MM CHARGE TE gt gt User manual DMX Tester Triton Blue Rev Sep 2013 www triton blue com ENGLISH For your own safety please read this user manual carefully before you initially start up Every person involved with the installation operation and maintenance of this device has to Be qualified Follow the instructions of this manual Consider this manual to be part of the total product Keep this manual for the entire service life of the product Pass this manual on to every further owner or use of the product Download the last version of the user manual from the internet in www triton blue com 1 1 MAIN FEATURES LIGHT amp HANDY PORTABLE AVAILABLE FOR TESTING SYNCHORNIZED SIGNAL DMX IN DMX OUT Built in battery it can work for several hours continuously Charge it 5 hours it can work 3 hours or waiting 100 hours LCD background lighting economizes on power to extend battery life Sleeping device Stop working in 5 Minutes running it will be in the mode of sleeping to extend battery life 1 2 TECHNICAL SPECIFICATIONS Power Supply DC 12V 1A DMX INPUT DMX512 DMX OUTPUT CHANNELS 512 CHANNELS DMX SIGNAL CONNECTOR XLR 3PIN x 2 gt PHONE JACK RJ11 x 2 OUTSIDE DIMENSIONS 100 W x 50 H x 133 L mm WEIGHT 750 g 1 3 FACEPLATE MANUAL DMX Tester 1
5. ed DMX IN memories LCD displays 2 4 OUT LEVEL SET Basically OUT LEVEL SET and DMX OUT have the same function they output a DMX 512 signal to control the dimming pack The only one difference is that OUT LEVEL SET can set different output level for individual channel from CH001 to CH512 but DMX OUT can only set the same output level for successive channels STEP 1 Press button DMX OUT 2 to go to function OUT LEVEL SET LCD display User manual DMX Tester Triton Blue Rev Sep 2013 www triton blue com gt DMX OUT sending frequency gt H ID display ROE nr The initial channel of OUT LEVEL 20 85 DMX OUT sending frequency this remains original DMX OUT frequency I H D It shows the current unit is Hexadecimal or Percent or Decimal C001 It means the current initial channel of OUT LEVEL STEP 2 You will find 00 in the first place is shinning it means the current controllable channel STEP 3 Push LEVEL revolving button to adjust SAGER level STEP 4 Press button or gt to adjust controllable channel When you press button P 3 times continuously LCD ea You ll find that CHO04 becomes the current controllable channel To put LEVEL revolving button to change output level of the said channel STEP 5 To press button again LCD displays CHO005 becomes the current controllable channel You ll find that initial channel of OUT LEVEL becomes C002 STEP 6 Y
6. en DMX IN OUT socket receive other DMX signal the way of LCD display is the same as in the mode of DMX OUT 4 4 3 DMX IN display in the mode of AUTO FADE User manual DMX Tester Triton Blue Rev Sep 2013 www triton blue com STEP 1 In the mode of AUTO FADE when DMX IN OUT socket receive other DMX signal the way of LCD display is the same as in the mode of DMX OUT 2 3 DMX IN STEP 1 Press button DMX IN to go to the function DMX IN LCD displays i aaa act gt START CODE gt DMX IN times of receiving gt H D display SEE ee ee er NE SSN 5 gt DMX IN initial channel START CODE It is the DMX IN start code level which is received DMX IN times of receiving It shows how many times DMX IN signal are received When the numbers of DMX IN receiving are higher than 99 it will be switch to received DMX IN frequency IHID It shows the current unit is Hexadecimal or Percent or Decimal C001 It means that the current DMX IN initial channel While the channel receives DMX IN signal LED of button DMX IN will be lighted STEP 2 If you would like to change the current initial channel press button or When you press button gt LCD display RIETS gt 20 S means the received DMX frequency is 20 times per second In the mode of DMX IN DMX Tester will remain previous status if you move the input DMX signal away you can press button DMX IN again to clean the receiv
7. nnel STEP 2 You ll find the current channel level CH001 is flowing 0 FL 0 STEP 3 The speed of AUTO FADE can be changed by LEVEL adjustment Push up to expedite AUTO FADE speed push down to reduce AUTO FADE speed User manual DMX Tester Triton Blue Rev Sep 2013 www triton blue com STEP 4 If you wish to amend channel press button tor gt While you press button gt LCD displays L J LJ CHO002 will proceed with AUTO FADE STEP 5 If you require successive multi channels to proceed with AUTO FADE you choose initial channel first then press button LCD displays While AUTO FADE is operating as below CH002 0 100 0 CH003 0 100 0 CHO002 0 gt 100 0 STEP 6 Press button or gt you can change ending channel When you press button LCD displays When you press button the ending channels are increasing STEP 7 In the same way while you press button lt to decrease ending channels When you press button 4 LCD displays 2 AUTO FADE sending frequency setup AUTO FADE has 2 kinds of sending frequency 20 S amp 40 S DMX sending frequency 20 S DMX sending frequency 40 S Press continuously button DMX OUT 1 you can switch between DMX OUT 20 S AUTO FADE 20 S DMX OUT 40 S and AUTO FADE 40 S 3 DMX IN display in the mode of AUTO FADE STEP 1 In the mode of AUTO FADE wh
8. ou can clean the set levels of all channels the set up by pressing and holding the button DMX OUT 2 2 seconds after that LCD displays 2 5 Hexadecimal Percent Decimal DISPLAY SETTING UP TEP 1 In the mode of DMX OUT it shows as percent LCD displays User manual DMX Tester Triton Blue Rev Sep 2013 www triton blue com TEP 2 Press button H to switch to Hexadecimal LCD will display STEP 3 Then press button H to switch f display The way to set up the display of Decimal and Hexadecimal and Percent is the same in AUTO FADE gt DMX IN and OUT LEVEL SET 2 BACKGOUND LIGHTING 6 LCD STEP 1 Press button LIGHT to turn on the LCD background light STEP 2 DMX Tester will automatically turn off background light after it doess not work in 10 seconds in order to enlarge battery life 2 7 MODE OF SLEEPING STEP 1 To enlarge battery life DMX Tester will get into the mode of sleeping after it does not work in 5 minutes LCD displays STEP 2 Press button DMX OUT to wake STEP 3 If you would like to turn off SLEEPING to press and hold button LIGHT Then turn on the power The function sleeping will be switched off 2 8 SYNCHRONAL SIGNAL OUTPUT DMX Tester can output DMX IN DMX OUT synchronal signal to proceeding observation by Wave Display Synchronal signal pk GND i SL l DMX IN TY oOOrE DMX OUT SV 10KO User manual DMX Tester Triton Blue Rev Sep 2013 www triton blue
9. splay CH002 gt CH003 will output 10 User manual DMX Tester Triton Blue Rev Sep 2013 www triton blue com STEP 5 At the same time you press button or gt you can choose ending channel You press button P again LCD display CH002 gt CH003 gt CH004 will output 10 STEP 6 You can also press button to reduce ending channel when you press button lt LCD display 2 DMX OUT sending frequency set up 2 kinds of sending frequency are available for DMX Tester they are 20 S 40 S respectively 1 gt 20 S is the DMX 512 signal sending 20 times of every second it is for normal dimmer pack to test data receiving 2 40 S is the DMX 512 signal sending 40 times of every second it is for dimmer pack to test high speed data receiving DMX sending frequency is 20 S DMX sending fre quency is 40 S STEP 1 In the mode of 20 S press button DMX OUT 1 to go to function AUTO FADE refer to 2 2 then press button DMX OUT 1 again to go back to the function of DMX OUT but at the same time you will find that LCD display DMX sending fre quency is 40 S STEP 2 In the same way in the mode of 40 S press continuously button DMX OUT 1 twiceto go to function of 20 S DMX OUT 3 In the mode of DMX OUT display of DMX IN The picture below shows the positions of communication outlets User manual DMX Tester Triton Blue Rev Sep 2013 www triton blue com In the mode of DMX OUT and