FA6150RF-GP INSTALLATION INSTRUCTIONS UL

image

Contents

1. 2 03
2. application Upon exiting the Program mode the FA6150RF GP alternately flashes Ad the 2 digit keypad address and the 2 digit receiver address If either of these is incorrect repeat steps 1 through 3 Programming for an Installation WITH Local Wireless Keys e The FA6150RF GP is supplied with default settings for the functions of the wireless keys See page 3 e If during the programming of the wireless keys you make a wrong entry and want to reprogram a wireless key simply press the key until d is displayed Then enter the correct information Perform steps 1 6 in the Programming for an Installation Without Local Wireless Keys section Then perform the following steps Step Action Display 1 Enter 3 House ID Enter the 2 digit House ID for the FA6150RF Alternately flashes hl anda GP 01 31 2 digit number Note The House ID is needed only if RF keypads and or bi directional units are used and House ID source is set for Local The House ID entered here MUST match the House ID programmed in the RF keypad and the bi directional unit Press the key to continue 2 Enter 8 Wireless Key Auto Enroll The FA6150RF GP Alternately flashes d with automatically advances to first available device number the device number and Note If all 8 devices have been enrolled the FA6150RF GP beeps three times and continues to alternately flash oo and 3 Press any button on th
3. keys will still function If you want only the encrypted wireless keys to operate be sure to delete all non encrypted keys from the system Defaulting the FA6150RF GP To restore the FA6150RF GP to the default values perform the following steps Step Action 1 Enter the Program mode by pressing the 1 and 3 keys simultaneously for a few seconds within 30 seconds after applying power The keypad alternately flashes 00 and two dashes Press the 9 key The display flashes EE Press the 1 key to restore the default values or press any other key to exit without restoring the default values If you pressed 1 the keypad beeps 3 times and returns to alternately flashing 00 and two dashes If you pressed any other key the keypad does not beep and returns to alternately flashing 00 and two dashes 4 Press k to exit the FA6150RF GP Program mode Programming Procedure This section is divided into two parts e Programming for an installation WITHOUT local wireless keys e Programming for an installation WITH local wireless keys Using the programming procedure WITH local wireless keys is necessary only if you plan to use wireless keys beyond the control panel s capacity or on a system that does not support 5800 Series wireless Refer to the FA6150RF GP Application Guide on page 2 for installations that require these settings Note See the control panel s
4. wireless keys e Provides a method for deleting a serial number and re enrolling a new one in its place e Provides default settings for the functions of the wireless keys Additional Features e Can send status signals Armed Ready etc to bi directional units such as 5804BD 5804BDV and 5827BD e Can operate the on board relay in conjunction with the receiver e g to trip a garage door opener e Can activate relays programmed into the control panel e Provides an End User mode to enable disable local wireless keys e g if a user accidentally loses a wireless key See the FA6150RF GP User Guide for this procedure Application Guidelines for the FA6150RF GP Use the following guidelines when planning an installation e Local wireless keys are programmed directly into the FA6150RF GP and may be used regardless of whether the RF receiver is enabled or disabled e If using bi directional devices be sure to enable the transmitter module in the FA6150RF GP e Iftransmitters are programmed into the control panel be sure to enable the receiver Make sure you do not exceed the number of receivers supported by the control panel e Ifa local wireless key is programmed to arm disarm or to trigger a relay on the control panel a user code must be entered into the FA6150RF GP This user code must also be programmed into the control panel e You must set the House ID only if you are using RF keypads and or bi directional devices AND the Ho
5. 50RF GP in an area and at a height where it is convenient for user operation The FA6150RF GP must be at least 10 from the control panel to ensure proper operation of the RF receiver WIRING TABLE Keypad Control Panel Wire Color DI Data In Green Ig Cr UE Be te z Aux Pwr GND Black FA O AA S Aux Pwr Red 5 DO Data Out Yellow 6150RF 002 O Figure 1 FA6150RF GP Wiring Connections To install the FA6150RF GP refer to Figure 1 for wiring connections and perform the following steps Step Action 1 Remove the case back by pushing down the two snaps along the FA6150RF GP s bottom edge and pulling the case apart 2 Route the wiring from the control panel through the opening in the case back See the control panel s instructions for proper wire run lengths Mount the case back directly to a wall or electrical gang box 4 Connect the power and data wires from the control panel to the terminals on the FA6150RF GP as indicated in the wiring table adjacent to Figure 1 above 5 Connect the wires for the relay output if used to the terminals on the FA6150RF GP s PC board 6 Reattach the keypad to its case back 7 Remove the clear protective films from the LCD display and install the keypad labels as required Note Upon power up or exit of the Program Mode the FA6150RF GP alternately flashe
6. K4460 GP 2 03 alert FAG150RF GP WWEEROFESSIONAL ys Keypad Transceiver INSTALLATION INSTRUCTIONS About the FA6150RF GP The Guardian Protection Services FA6150RF GP keypad transceiver is a combination unit that contains e A6150 Fixed Addressable Keypad e A5800TM Transmitter Module e A5881M RF Receiver e Anormally open relay output The FA6150RF GP Keypad Transceiver may be used on any control panel that supports the FA260KP Keypad e g FA142C FA162C FA1220C FA1340C FA110C FA120C FA1200C Features of the FA6150RF GP Wireless Features e Supports up to 8 wireless keys locally programmed directly into FA6150RF GP without occupying any zones supported by the control panel e Supports button type transmitters 5804 5804BD for local operation e Supports a maximum of 16 transmitters programmed into any 5800 Series supported control panel e Provides low battery indications for the local wireless keys e Supports wireless keys with Signal Sentry high security 5804E e Provides a nominal range of 200 for the RF transmitters some transmitters have a shorter range e Supports RF jam detection when the receiver is enabled e Provides wireless key support for control panels that do not support RF themselves such as FA110C U The following transmitters are not intended for use in UL installations 5804 5804BD 5804BDV 5804E L and 5827BD Programming Features e Provides an Auto Enroll mode for programming of the
7. Note The FA6150RF GP is shipped with the loop functions pre programmed Perform steps 6 through 10 only if it is necessary to change any of the loop functions Loop 1 Close the FA6150RF GP On Board Relay for 2 sec Loop 2 1 Disarm Loop 3 2 Arm Away Loop4 3 Arm Stay See the Wireless Key Function Chart below for the choices Wireless Key Function Chart Function Entry Disarming Arming Away Arming Stay Arming Maximum Away Instant Arming Instant FE N A oj N Panic Alarm 99 Produces type of alarm amp programmed in control panel Manually Start a Relay Action 7 VISTA 10SE VIA 30PSE 7 n VISTA 20SE HW 8 VISTA 10SE VIA 30PSE 8 n VISTA 20SE HW 71 VISTA 40 VISTA 50P Manually Stop a Relay Action Activate Relay as Programmed in Control Activate Relay as Programmed in Control Activate Access Control Relay for Partition 72 VISTA 40 VISTA 50P 0 VISTA 40 VISTA 50P n Device Number programmed in VISTA 20SE HW to be controlled Press the key Flashes Ln Once the loop number is entered alternately flashes L with the loop number and the present function Default Loop Functions Loop 3 Arm AWAY Loop 2 Loop 4 Disarm Arm STAY Loop 1 Close on board relay for 2 seconds Loop 2 Disarm Loop 4 Arm STAY Loop 1 Close on board relay for 2 seconds Loop 3 A
8. VDC Frequency 345 MHz Sounder Piezo electric fire alarm is loud pulsing tone burglary audible panic alarm is continuous tone FOR DETAILS ON THE LIMITATIONS OF THE ENTIRE ALARM SYSTEM REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED FCC STATEMENT This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC ID CFS8DLFA6150RF GP FEDERAL COMMUNICATIONS COMMISSION FCC Part 15 STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use The FCC requires the following statement for your information This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules which are designed to provide reasonable protection against such interference in a residential installation However there is no guarantee that interference will not occur in a particular installation If this equipment does cause interference to radio or television recepti
9. cal to use the House ID programmed into the FA6150RF GP Program Address 3 Note If the House ID Source is e System 1 RF keypad and bi directional units MUST match the House ID programmed into the control panel e Local 0 RF keypad and bi directional units MUST match the House ID programmed into the FA6150RF GP Press the key to continue Step Action Display Enter 6 Receiver Enable Enter 1 to enable or 0 to disable Enable the receiver if RF transmitters or wireless keypads are programmed into the control Note Make sure the number of receivers set for Enable 1 does not exceed the capacity of the control panel Press the gt key to continue e Alternately flashes r and either 1 or 0 Enter 7 Transmitter Module Enable Enter 1 to enable or 0 to disable Enter 1 if bi directional devices are being used Note If the House ID Source is System and more than one FA6150RF GP is used make sure only one has the Transmitter Module enabled See Note under House ID Source step 4 Press the key Alternately flashes tE and either 1 or 0 Enter 0 High Security Mode To put the system into High Security mode enter 1 Enter 0 to disable En 8 Press the key to exit the FA6150RF GP Program mode READY or NOT READY Note This is all the FA6150RF GP programming necessary for this
10. digit keypad address and the 2 digit receiver address If either of these is incorrect repeat steps 1 through 3 in the Programming for an Installation Without Local Wireless Keys section Deleting Replacing or Editing Wireless Keys Use the following procedure to delete replace or change any of the programming for a wireless key Step Action Display 1 Enter the Program mode by pressing the 1 and 3 keys simultaneously for a few seconds within 30 seconds after applying power Alternately flashes oo and two dashes Enter 5 Wireless Key Editing Enter the device number for the wireless key you want to edit This must be a device that has its serial number programmed in the FA6150RF GP already To delete the serial number press then press 9 then press again To exit without deleting the serial number press the key Press the key to continue Flashes the device number and a hyphen Once the device number is entered alternately flashes d with the device number and the serial number To change any of the programming for the wireless key perform one of the following step in the Programming for an Installation WITH Local Wireless Keys section e For the user code perform step 5 e For the loop functions perform steps 6 and 7 e For the on board relay assignment perform steps 8 to 9 Alternately flashes d with the device number and Wh
11. e wireless key to enroll the serial number Alternately flashes d with Note If enrolling a wireless key 5804E in high security mode press the device number and the all four buttons on the wireless key simultaneously serial number 4 Press the key to accept the serial number OR press the key If you accept the serial to reject the serial number number the display flashes If you accept the serial number the FA6150RF GP beeps twice If the device number and a you reject the serial number the FA6150RF GP returns to the hyphen enroll serial number prompt If you reject the serial Note A maximum of 8 wireless keys may be enrolled into the number the display FA6150RF GP These wireless keys DO NOT occupy any alternately flashes d with zones supported by the control the device number and If you are finished programming for now press to exit Otherwise continue with step 5 5 Enter 2 User Code Enter the 4 digit user code for the wireless Flashes u4 Once the 4 digit key user code is entered the Note The user code must be a valid code that is programmed in the display flashes u4 the first control panel two digits and then the last Press the key to accept the user code two digits of the user code If you are finished programming for now press k to exit Otherwise continue with step 6 Step Action Display Enter 4 Loop Functions Enter the loop number 1 4
12. en you have completed editing the wireless keys press the key twice to exit the Program mode Note Upon exiting the Program mode the FA6150RF GP alternately flashes Ad the 2 digit keypad address and the 2 digit receiver address If either of these is incorrect repeat steps 1 through 3 in the Programming for an Installation Without Local Wireless Keys section Troubleshooting The following error messages cause the FA6150RF GP to produce rapid beeps for 5 seconds The table below describes the error messages and the corrective actions Display Probable Cause Corrective Action Lb Low battery in the wireless 1 Replace the battery if the wireless key has a replaceable key battery 2 Replace the transmitter if the wireless key does not have a replaceable battery Oc Open circuit Verify that the Data Out DO wire is connected properly 1C Incompatible connection Verify that the control panel is not a First Alert type control panel Check 09 1 FA6150RF GP 1 Verify that the Data In DI wire is connected properly Receiver is not communicating 2 Verify the wiring connections between the control and all 2 Another device on the other devices keypad terminals is not communicating to the control panel Specifications Physical 6 1 4 H x 4 7 8 W x 1 D Current Standby 80mA Wiring Refer to Wiring Table on page 2 Sounder on 105mA Range 200 nominal Relay Normally Open 1A 28
13. installation instructions for the acceptable keypad and receiver addresses e If you are using a wireless key in High Security mode 5804E in the control panel it will occupy one of the devices in the FA6150RF GP e When operating the system in High Security mode non encrypted wireless keys will still function If you want only the encrypted keys to operate be sure to delete all non encrypted keys from the system Programming for an Installation WITHOUT Local Wireless Keys To program the FA6150RF GP for an installation without any local wireless keys perform the following steps Step Action Display 1 Enter the Program mode by pressing the 1 and 3 keys Alternately flashes oo and simultaneously for a few seconds within 30 seconds after applying two dashes power or within 30 seconds after removing the case back 2 Enter 1 Keypad Address Enter the 2 digit keypad address 01 Alternately flashes cA and 31 Press the key to continue the 2 digit keypad address 3 Enter 2 Receiver Address Enter the 2 digit receiver address 00 Alternately flashes rA and 30 Press the gt key to continue the 2 digit receiver address 4 Enter 4 House ID Source Enter 1 System to use the House Alternately flashes hl and ID programmed into the control panel if RF keypad s and or bi either 1 or 0 directional device s e Are used on the control panel OR e Neither is used Enter 0 Lo
14. m mode e Pressing the key stores the information displayed then moves you to the next prompt and the keypad beeps twice e Pressing the key erases the current information and moves you back so you may enter the correct information Enter a program address e g press 1 for Keypad Address 2 for Receiver Address to set the parameters in the FA6150RF GP The following chart lists the program addresses the keypad display and the choices Program er i Address Description Display Choices Default 1 Keypad Address cA 01 31 31 2 Receiver Address rA 00 30 00 3 House ID hl 01 31 4 House ID Source hS 1 System 1 System 0 Local 5 Wireless Key Editing d Enter Existing Device Number 6 Receiver Enable i 1 On 0 Off 1 Enable 7 Transmitter Module Enable tE 1 On 0 Off 1 Enable 8 Wireless Key Auto Enroll d Enter Serial Number 8 then 2 Wireless Key User Code u4 Enter 4 Digit User Code 8 then 4 Wireless Key Loop Function Ln Enter Loop Number then Loop2 1 Disarm Function See Wireless Loop 3 2 Arm Away Key Function Chart Loop4 3 Arm Stay 8 then 5 Wireless Key On Board o Enter Loop Number then Loop 1 Close for 2 Relay Assignment Relay Action Seconds 9 Restore Defaults EE 1 Restores Defaults Any Other Key Does Not Restore Defaults 0 High Security Mode En 1 Enable 0 Disable 0 Disable When operating the system in High Security mode non encrypted wireless
15. on which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures If using an indoor antenna have a quality outdoor antenna installed Reorient the receiving antenna until interference is reduced or eliminated Move the radio or television receiver away from the receiver control Move the antenna leads away from any wire runs to the receiver control Plug the receiver control into a different outlet so that it and the radio or television receiver are on different branch circuits If necessary the user should consult the dealer or an experienced radio television technician for additional suggestions The user or installer may find the following booklet prepared by the Federal Communications Commission helpful Interference Handbook This booklet is available from the U S Government Printing Office Washington DC 20402 The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User s Manual Unauthorized changes or modifications could void the user s authority to operate the equipment REFER TO INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED FOR WARRANTY INFORMATION AND LIMITATIONS OF THE ENTIRE ALARM SYSTEM First Alert Ww NS PROFESSIONAL SECURITY SYSTEMS 149 Eileen Way Syosset New York 11791 Copyright 2003 PITTWAY CORPORATION K4460 GP
16. rm AWAY SET HOUSE CODE 5804BD 5804BDV Repeat step 6 for the rest of the loops of the wireless key To program a button on the wireless key to control the on board relay enter 5 On Board Relay Assignment Flashes o Enter the loop number of the wireless key 1 4 Enter the relay action 0 no action 1 relay off 2 relay on 3 relay toggles on and off 4 relay closes for 2 seconds Note The relay action must be 0 for UL installations Press the key 9 Flashing o number and the loop Once the action is entered displays o and alternately flashes the loop number and the relay action 10 Repeat step 9 for the rest of the loops 11 When all loops have been programmed for the wireless key press the key Flashes d followed by the device number 12 The FA6150RF GP automatically displays the next available device number one that does not have a serial number If you want to program additional wireless keys repeat steps 3 through 10 Otherwise press the key This takes you back to the main display which alternately flashes oo and 13 Enter 0 High Security Mode To put the system into High Security mode enter 1 Enter 0 to disable En 14 Press to exit the FA6150RF GP Program mode Note Upon exiting the Program mode the FA6150RF GP alternately flashes Ad the 2
17. s Ad and the 2 digit keypad address and the 2 digit receiver address on the display Press any key to display the system status FA6150RF GP Programming The FA6150RF GP is shipped with pre programmed default values Below is a chart showing these values Later in these instructions are diagrams showing the wireless keys loops and their default functions Regardless of which wireless key you use even if it is one not shown loops 1 4 are defaulted for all 8 devices as shown These values may be changed to suit the installation Entering Program Mode Press the 1 and 3 keys simultaneously for a few seconds within 30 seconds after applying power or within 30 seconds after removing the case back The keypad beeps 3 times and two dashes and two zeroes flash alternately in the upper left hand corner of the display If any other numbers or letters flash in the display press the key Pressing the 1 and 3 keys 30 seconds or more after applying power allows you to enter the User mode This mode provides a means to enable and disable individual local wireless keys useful if e g a user accidentally loses a wireless key See the User Guide for procedure instructions Programming Operations Once you have entered the Program mode you may move to any program address simply by entering the program address number The FA6150RF GP will automatically exit the Program mode if no keys are pressed for 30 seconds While in the Progra
18. use ID Source is the FA6150RF GP Local FA6150RF GP Application Guide Below is a guide that outlines how to program the wireless keys RF receiver and the House ID in the FA6150RF GP for your particular installation Control Panel Are you using RF keys RF receivers RF keypads and or Program Program House ID beyond beyond Bi directional Wireless Keys RF Source system s system s devices on more As Receiver As capacity capacity than 1 partition FA110C FA120C FA1200C Disable Local 0 FA130C CP FA142C Use Programming Without Local Wireless Keys FA148C CP Local Enable 1 System 1 Local Disable 0 Local 0 FA162C FA168C CP Use Programming Without Local Wireless Keys FA168CP GP Local Enable 1 System 1 Local Disable 0 Local 0 System Disable 0 Local 0 Local Disable 0 Local 0 FA1220C FA1340C Use Programming Without Local Wireless Keys Local Enable 1 System 1 Local Disable 0 Local 0 System Disable 0 Local 0 Local Disable 0 Local 0 Two FA6150RF GPs are needed for this application For FA162C connect one to partition 1 keypad terminals and one to partition 2 s Tf using an RF keypad on only one partition the FA6150RF GP s partition assignment must match the partition set in field 1 48 Tf set for Local on a partition control the FA6150RF GP s partition assignment must match the one programmed in the BD device Installing the FA6150RF GP Locate the FA61