Home
CP-132U Series User`s Manual
Contents
1. DIP Switch Port 1 Settings S1 1 S2 1 2 WIRE RS485 RS 422 OFF n S1 4 WIRE RS422 2 WIRE RS485 RS 485 2 wire En ON al S1 4 WIRE RS422 2 WIRE RS485 RS 485 OFF ON 4 wire S1 4 WIRE RS422 DIP Switch Port 2 Settings S1 2 S2 2 2 WIRE RS485 RS 422 OFF n S1 4 WIRE RS422 2 WIRE RS485 RS 485 S1 S2 4 WIRE RS422 2 WIRE RS485 RS 485 OFF oN 4 wire S1 S2 4 WIRE RS422 2 4 CP 132U Series User s Manual Hardware Installation Plugging the Board into an Expansion Slot Since the CP 132U series board s IRQ number and I O address are automatically assigned by the PCI BIOS the board MUST be plugged into one of the computer s expansion slots before installing the driver Step 1 Power off the PC A WARNING To avoid damaging your system and board make sure your computer is turned off before installing any serial board Step 2 Remove the PC s cover Step 3 Remove the slot cover bracket if there is one Step 4 Use the onboard DIP Switches to set the transmission mode for each port see the previous section for details Step 5 Plug the CP 132U board firmly into a free 32 bit PCI slot Step 6 Fasten the holding screw to fix the control board in place Step 7 Replace the PC s cover Step 8 Power on the PC The BIOS will automatically set the IRQ and I O address NOTE Moxa PCI and Universal PCI boards must be assigned unique IRQ
2. gt e Scan for hardware changes Properties Uninstalls the driver for the selected device 2 Click on OK to proceed with uninstalling the board Confirm Device Removal ax lp MOXA CP 118U Series PCI Bus Warning You are about to uninstall this device from your system Cancel 3 25 CP 132U Series User s Manual Software Installation 3 The Device Manager window refreshes automatically showing that the driver and ports for the CP 132U series board have been removed E Device Maneger A File Action View Help gt 5 6 2 2 y Computer amp Disk drives 2 Display adapters 2 DVD CD ROM drives 2 Floppy disk controllers JA Floppy disk drives 2 IDE ATA ATAPI controllers gt Keyboards 5 Mice and other pointing devices 22 Monitors E Network adapters A Ports COM amp LPT I Communications Port COM1 HF Communications Port COM2 4 Printer Port LPT1 SB Processors Sound video and game controllers 4 System devices Te Fe Be Jiu El E Windows 95 98 In this section we describe the installation procedure for Windows 98 The installation procedure for Windows 95 is similar The Windows 95 98 driver supports up to 128 serial ports from COM1 to COM128 To utilize fully the advanced multi process and multi thread features of Windows 95 9
3. e Scan for hardware changes Properties lUninstalls the driver For the selected device 2 Click on OK to proceed with uninstalling the board Confirm Device Removal ax Ip MOXA CP 118U Series PCI Bus Warming You are about to uninstall this device from your system Cancel 3 13 CP 132U Series User s Manual Software Installation 3 The Device Manager window refreshes automatically showing that the driver and ports for the CP 132U Series board have been removed 215 xi File Action view Help 5 0182 32 Computer amp Disk drives 2 Display adapters A DVD CD ROM drives 2 Floppy disk controllers 43 Floppy disk drives 3 IDE ATA ATAPI controllers gt Keyboards 3 Mice and other pointing devices 22 Monitors E9 Network adapters 4 Ports COM amp LPT Communications Port COM1 Communications Port COM2 a Printer Port LPT1 SB Processors Sound video and game controllers 1 System devices 2 0 2 0 2 1 1 j f L H E Windows 2000 In this section we describe the installation procedure for Windows 2000 Windows 2000 supports up to 256 serial ports from COM1 to COM256 In order to utilize fully Windows 2000 s multi process and multi thread advanced features pure 32 bit Windows 2000 device drivers were developed for Mo
4. Ax bytes 1s Ax History Port Name COMS Port Status m Communication Parameter HZ Flow Control Pree recy Baud Rate bps 38400 RTS Flow Control opsed tine 00 04 Data Bits 8 CTS Flow Control CP 132U Series User s Manual Serial Programming Tools Terminal Emulator Use Terminal Emulator to connect to your PC s serial ports to check if data is being transmitted correctly Terminal Emulator features multi windows and supports VT 100 and ANSI terminal types You can transfer data interactively send patterns periodically and transfer files using ASCII XMODEM YMODEM ZMODEM and KERMIT protocols To run Terminal Emulator click on Start gt Program gt Pcomm Lite gt Terminal Emulator E3 PComm Terminal COM44 38400 None_8 1 Dumb Terminal File Edit PortManager Port Window Help a AA Blas s xenix386 login root Password Welcome to SCO XENIX System V fram ES C0M44_38400 None 8 1 Dumb Terminal mar 0123456789abcae ghij012345678 abcde fghij0123456789abcde fghij01234 i 0123456789abcde fghij0123456789abede fghij0123456789abcde fghij01Z3 ou have nai oR 0123456789 abcde fghij0123456789 abcde fghij0123456789 abcde fghij01Z3 TERM ansi ers lo123456789abcdefghij0123456789abcdefghij0123456789abcdefghij0123 lo 0123456789abcdefghij0123456789abcdefyhij0123456789abcdefghij0123 profile 0123456789 abcde fghij0123456789 abcde fghij0123456789 abcde fghij
5. Total Configuration Boards 1 COM Port Available Boards 1 NOTE The PComm Lite software can downloaded for free from Moxa s website at www moxa com support free_downloads htm Using Event Log To use the Event Log to check the installation of your Moxa boards click on Start gt Settings gt Control Panel gt Administrative Tools gt Event Viewer to enter the Event Viewer utility Look under the System category to find the latest information relevant to Moxa s drivers 3 12 CP 132U Series User s Manual Software Installation Removing the Driver 1 To uninstall the driver click on Start gt Settings gt Control Panel gt System select the Hardware tab and then click on Device Manager Use the mouse to place the cursor over the CP 132U Series board under Multi port serial adapters and then click the right mouse button Select the Uninstall option 0 File Action View Help e mea 2 azra WINXP PRO 4 Computer Disk drives 2 Display adapters 2 DYD CD ROM drives Floppy disk controllers J Floppy disk drives 2 IDE ATAJATAPI controllers gt Keyboards 5 Mice and other pointing devices Monitors 3 Multi port serial adapters E mMoxa CP 118U Serjes Pc E9 Network adapters Update Driver 4 Ports COM amp LPT Disable 8 Sound video and game 4 System devices Ee EB Ge
6. Hardware Installation i 1 The software you are installing for this hardware e a MOXA CP 118U Series PCI Bus has not passed Windows Logo testing to verify its compatibility with Windows XP Tell me why this testing is important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing Continue Anyway STOP Installation 3 4 CP 132U Series User s Manual Software Installation 5 Wait while the driver software is installed Found New Hardware Wizard Please wait while the wizard installs the software SS al MOXA CP 118U Series PCI Bus mxsictg dil To F WINXP System32 COLT 6 The next window shows the model name of the board and indicates that Windows has completed the driver installation Click on Finish to proceed with the rest of the installation procedure Found New Hardware Wizard Completing the Found New gt Hardware Wizard The wizard has finished installing the software for lp MOXA CP 118U Series PCI Bus Click Finish to close the wizard lt Back 3 5 CP 132U Series User s Manual Software Installation 7 The Found New Hardware Wizard window will open to help you install the driver for
7. Found New Hardware Wizard Install Hardware Device Drivers SS A device driver is a software program that enables a hardware device to work with CY an operating system This wizard will complete the installation for this device ay PCI Serial Port 4 device driver is a software program that makes a hardware device work Windows needs driver files for your new device To locate driver files and complete the installation click Next What do you want the wizard to do Display a list of the known drivers for this device so that can choose a specific driver a 4 Select Specify a location and then click on Next to continue Found New Hardware Wizard Locate Driver Files SS Where do you want Windows to search for driver files SY Search for driver files for the following hardware device oy PCI Serial Port The wizard searches for suitable drivers in its driver database on your computer and in any of the following optional search locations that you specify To start the search click Next If you are searching on a floppy disk or CD ROM drive insert the floppy disk or CD before clicking Next Optional search locations TE T CD ROM drives IV Specify a location Microsoft Windows Update lt Back Cancel 3 16 CP 132U Series User s Manual Software Installation 5 Navigate to the CP 132U Software Win2K XP 2003 folder on the software CD and then click on OK to continue
8. Found New Hardware Wizard xi ues easy H CP 118U Softwares win2K XP 2003 vi 6 Click on Next to copy the driver files to your system Found New Hardware Wizard Driver Files Search Results The wizard has finished searching for driver files for your hardware device CP 132U Series User s Manual Software Installation 7 Wait while the installation wizard searches The next window that opens cautions you that although this software hasn t passed Windows Logo testing the driver has been tested and shown that it can support the Windows OS Click on Yes to proceed Digital Signature Not Found CP 132U Series User s Manual Software Installation 9 10 11 The next window shows the model number of the board and indicates that Windows has completed the driver installation Click on Finish to continue with the rest of the installation procedure Found New Hardware Wizard Completing the Found New Hardware Wizard xy MOXA CP 118U Series PCI Bus Windows has finished installing the software for this device To close this wizard click Finish lt Back The Found New Hardware window will reappear and indicate that the board s ports are being installed Found New Hardware A X PCI Serial Port Installing The installation procedure is finished when the window closes At this point you can assume that the board and all of its ports have been installed success
9. tar xvfz mxser tgz cd mxser make clean make install cd moxa mxser driver msmkod modprobe mxser If you install ISA Boards use the command insmod mxser ioaddr 0x 0x 0x 0x lt Ist ISA 2nd ISA 3rd ISA 4th ISA Using lib modules 2 4 20 8 kernel drivers char mxser o Warning loading lib modules 2 4 20 8 kernel drivers char mxser o will taint the kernel no license See http www tux org lkml export tainted for information about tainted modules Moxa Smartio Industio family driver version 1 7 Tty devices major number 30 callout devices major number 35 Found Moxa CP 132U series board BusNo 2 DevNo 13 Module mxser loaded with warnings Use the Moxa diagnostic utility to verify the driver status cd moxa mxser utility diag msdiag Moxa Smartio Industio Family Multiport Board Status Utility 1 1 Tty Device Major Number 30 Callout device Major Number 35 Board 1 CP 132U series BusNo 2 DevNo 13 Port 1 Oxac00 max baud rate 230400 bps Port 2 Oxac08 max baud rate 230400 bps Port 3 Oxacl0 max baud rate 230400 bps Port 4 Oxacl8 max baud rate 230400 bps Port 5 Oxac20 max baud rate 230400 bps Port 6 Oxac28 max baud rate 230400 bps Port 7 Oxac30 max baud rate 230400 bps Port 8 Oxac38 max baud rate 230400 bps Use the Moxa terminal utility to test the tty ports Hcd moxa mxser utility te
10. Driver 1 9 0 Total Configuration Boards 1 COM Port Available Boards 1 NOTE The PComm Lite software can downloaded for free from Moxa s website at www moxa com support free_downloads htm Using Event Log To use the Event Log to check the installation of your Moxa boards click on Start gt Settings gt Control Panel gt Administrative Tools gt Event Viewer to enter the Event Viewer utility Look under the System category to find the latest information relevant to Moxa s drivers 3 24 CP 132U Series User s Manual Software Installation Removing the Driver 1 To uninstall the driver click on Start gt Settings gt Control Panel gt System select the Hardware tab and then click on Device Manager Use the mouse to place the cursor over the CP 132U Series board under Multi port serial adapters and then click the right mouse button Select the Uninstall option O 2 Fie Action View Help e nE 8S R a 8a WINXP PRO 24 Computer Disk drives 2 Display adapters 2 DVD CD ROM drives Floppy disk controllers JB Floppy disk drives 2 IDE ATAJATAPI controllers se Keyboards 5 Mice and other pointing devices Monitors 3 Multi port serial adapters Sy MOXA CP 118U Serjes Pc Sl E Network adapters Update Driver 4 Ports COM amp LPT Disable Sound video and game 14 System devices ef
11. Moxa Port 0 Select Install from a list or specific location Advanced and then click on Next to proceed Found New Hardware Wizard Welcome to the Found New gt Hardware Wizard This wizard helps you install software for MOXA Port 0 E If your hardware came with an installation CD QP or floppy disk insert it now What do you want the wizard to do Install the software automatically Recommended Click Next to continue cme 8 Select Search for the best driver in these locations check Include this location in the search and then click on Browse If necessary use the Browse button to navigate to the CP 132U Software Win2K XP 2003 folder and then click on Next to proceed Found New Hardware Wizard 4 Please choose your search and installation options SS Use the check boxes below to limit or expand the default search which includes local paths and removable media The best driver found will be installed J Search removable media floppy CD ROM Y Include this location in the search Hace 18U4S oftware Win2K lt P 2003 v Browse C Don t search will choose the driver to install Choose this option to select the device driver from a list Windows does not guarantee that the driver you choose will be the best match for your hardware ao 3 6 CP 132U Series User s Manual Software Installation 9 Wait while the installation wizard searches The next
12. 485 ports Universal PCI interface with embedded Surge Protection 16 KV ESD CP 132UL I V2 2 RS 422 485 ports Universal PCI interface with embedded Surge Protection and Isolation Protection 16 KV ESD 2 KV Isolation The CP 132U series board has the following outstanding features 2 independent 422 RS 485 serial ports Supports Universal PCI Data flow LED display onboard Moxa UART with 128 byte FIFO driver 50 bps to 921 6 Kbps transmission speed Supports both 4 wire and 2 wire RS 485 2 wire RS 485 data control with ADDC Embedded 15 KV ESD surge protection Drivers for all major industrial platforms Windows 2000 XP 2003 Windows NT Windows 95 98 Windows XP Embedded Linux FreeBSD SCO Package Checklist The following items are included in the CP 132U package CP 132U 2 port serial board Documentation and Software CD ROM Quick Installation Guide NOTE Notify your sales representative if any of the above items are missing or damaged CP 132U Series User s Manual Introduction Installation Flowchart The following flowchart gives a brief summary of the procedure you should follow to install the CP 132U series board and which chapters to refer to for more detailed information Use the onboard DIP Switches to select the o i data transmission mode for each port Chapter 2 Hardware Installation Install the board in a PCI or PCI X expansion slot Chapter 2 Hardware Installation Install the driver a
13. Bose ett EEE tated ose a RO OO ON toa ad 3 45 UA o e aed cents Sake ces EAE Mn Uae ed a ee 3 48 Serial Programming Tools ecccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeseneeeeeesseneeneeeees 4 1 Moxa PCOMM o reinen sa E taco added diia da 4 2 Installing PCotm iii decada eaea 4 2 PComm Programming Library ooooconncnnccnocnnonnoonconoconccnncnn nooo nooo nonnnonn ron n oran ronca nn rn nncn neos 4 2 Utilities seed 4 3 Diagnostic for Moxa boards Only ccccecceescessceeseeseceseceneceecaeeeseeeaeeseeeeeeeeseneeeeeenaees 4 3 Monitor for Moxa boards under Windows NT 2000 XP 2003 sssr 4 4 Terminal Emulator onre a E ee EE ts 4 5 RS 485 Programing ds 4 5 ADDE Mo A N E N E fiolesvele olesbertelesgeve outed 4 5 Pin Assignments ui ad 5 1 Board Side Pin Assignments Female DB25 0 ecceccceseceseeesecececeeeeeeeeneeeeeeeeeeeeneeneeneensees 5 2 Device Side Pin Assignment nte KARR aN rhein ad BAe 5 3 Male DBS vicio dei dav EAS qa eones 5 3 Cable Witing sd ee AL ROA iano a AER e 5 3 Impedance Matching and Termination Resistors ccscceseeesecsceeseeeeeeeseeeeeeeeeeereneeneeeneensees 5 5 Troubleshooting tio 6 1 General Troubleshooting eiii nidad atada did 6 1 Windows DTi ia 6 2 Windows 95 98 iii id 6 2 Technical Reference iia ca ccicceiiccciceeececcset cece tecresniveetiveeiceerstedeecseceisdcenncreneresess A 1 Product Speciticath ons ia ci A 1 O ee OR NN A 2 Moxa DAR To A AE A 2 Service Information athe este eee adi
14. and I O addresses Both addresses are assigned automatically by the PCI BIOS Step 9 Proceed with the software installation discussed in the next chapter Software Installation 3 Software Installation In this chapter installation configuration and update removal procedures for the driver are given for Windows 2003 XP 2000 98 95 NT DOS Linux and SCO Before proceeding with the software installation complete the hardware installation discussed in the previous chapter Hardware Installation Refer to the next chapter Serial Programming Tools for information about developing your own serial programming applications Note that up to 4 CP 132U boards can be installed in one system provided sufficient I O address and IRQ number resources are available Windows 2000 XP 2003 Windows XP Embedded Windows NT Windows 95 98 DOS FreeBSD Linux and SCO drivers can be downloaded from the Moxa website The following topics are covered in this chapter UU Windows Drivers gt Windows 2003 XP gt Windows 2000 gt Windows 95 98 gt Windows NT Q Non Windows Drivers gt DOS gt Linux CP 132U Series User s Manual Software Installation Windows Drivers Moxa provides drivers that allow you to use the following serial board products under Windows 2003 XP 2000 Windows XP Embedded Windows 98 95 and Windows NT e Universal PCI Boards CP 168U CP 104UL CP 104JU CP 134U CP 134U I CP 132UL
15. and Software CD Note that the PComm diagnostic and monitor utilities are for Moxa boards only To use these utilities you must have a Moxa board and the appropriate Windows 95 98 NT 2000 XP 2003 device driver installed in your system See the Software Installation chapter for instructions on how to install the drivers After installing PComm click on Start select Program Files and then the PComm Lite group to select from the list of utilities and documents PComm Programming Library The serial communication library helps you develop serial communications programs for any COM port that complies with the Microsoft Win32 API This library facilitates the implementation of multi process multi thread serial communication programs and greatly reduces the time required to develop applications For a complete description of the library functions and sample programs for Visual C Visual Basic and Delphi check the help file and the sample programs in the PComm directory 4 2 CP 132U Series User s Manual Serial Programming Tools Utilities In this section we give brief descriptions of each utility For more information about these utilities read the on line help from the Documentation and Software CD Diagnostic for Moxa boards only This convenient diagnostic program which only works with Moxa boards and ports provides internal and external testing of IRQ TxD RxD UART CTS RTS DTR DSR DTR DCD etc The diagnostic
16. appears Click on Add to open the Property configuration window to change port settings and set advanced FIFO configuration options A Moxa Smartio Industio Configuration Panel 8 Continue from Step 3 in the next section Configuring the Ports Configuring the Ports Follow the instructions in this subsection if the CP 132U Windows NT driver is already installed and you wish to re configure a board s ports or configure the ports of a newly installed board In addition to the procedures listed below you may also click on Start gt Programs gt Moxa Utility gt Moxa Smartio Industio Configuration Panel gt Property and then refer to the instructions in the previous section Installing the Driver for the First Time 3 39 CP 132U Series User s Manual Software Installation 1 Open the Control Panel click on the Network icon and then select the Adapters tab Click on Moxa Smartio Industio Family Adapter to highlight it and then click on Properties E 2 D Link DFE 530TX PCI Fast Ethernet Adapter Rev A tio Industio Family Adapter MOXA Smartio Industio Family Adapter 2 Select the board whose ports you wish to configure to highlight it and then click on Property G Moxa Smartio Industio Configuration Panel B000 3 Select the just installed CP 132U board from the Board Type pull down list click on a specific port to highlight it and then click on Port Setting
17. device drivers are provided for smoother installation configuration and performance In this manual we give installation details for Windows 2003 XP Windows 2000 Windows NT Windows 95 98 DOS Linux and SCO Visit Moxa s website at www moxa com to download the latest drivers and user s manuals for all of Moxa s products Universal PCI The 32 64 bit PCI local bus specification requires that PCI hardware be compatible with both 3 3V and 5V connector types Moxa s universal PCI cards can be plugged into 3 3V or 5V and 32 bit or 64 bit slots Moxa Serial Comm Tool For application development Moxa provides an easy to use serial communication library called PComm that runs under Windows NT 2000 XP 2003 95 98 Use this library to develop your own applications with Visual Basic Visual C Borland Delphi etc Utilities such as Data Scope Monitor Terminal Emulator and Diagnostics are included to make it easier to debug monitor communication status provide terminal emulation and transfer files CP 132U Series User s Manual Introduction Applications The CP 132U series board is suitable for many different applications including Features Internet Intranet Connections Remote Access Multi user Applications Industrial Automation Office Automation Telecommunications PC based Vending Machines and Kiosks POS Point of Sale Systems The CP 132UL Series includes the following products CP 132UL V2 2 RS 422
18. receiving since the switching mechanism is managed automatically by the board s built in intelligent hardware mechanism This means that RS 485 programming using ADDC mode is just as simple and straightforward as RS 422 programming 4 5 5 Pin Assignments The CP 132U board has a female DB44 connector on the board with various connection options available for connecting from the board to your serial devices In this chapter we give pin assignments for the board side connector as well as pin assignments for device side connectors for the different connection options The CP 132U board supports RS 422 4 wire RS 485 and 2 wire RS 485 Note that the RS 422 standard uses a balanced voltage digital interface to allow 9600 bps communication over cables of up to 4000 feet in length Ten receivers can be connected to one driver for broadcasting systems The RS 485 standard is an enhanced version of the RS 422 balanced line standard It allows multiple drivers and receivers to work on a multidrop network A maximum of 32 drivers and 32 receivers can be set up on a multidrop network The CP 132U board supports both 2 wire half duplex and 4 wire full duplex RS 485 communications In 2 wire RS 485 Data pins are used for both data transmitting and receiving The following topics are covered in this chapter Q Board Side Pin Assignments Female DB25 Q Device Side Pin Assignments gt Male DB9 gt Cable Wiring Q Impedance Matching and Ter
19. the information herein to correct such errors and these changes are incorporated into new editions of the publication Technical Support Contact Information WWw moxa com support Moxa Americas Moxa China Shanghai office Toll free 1 888 669 2872 Toll free 800 820 5036 Tel 9 1 714 528 6777 Tel 86 21 5258 9955 Fax 1 714 528 6778 Fax 86 10 6872 3958 Moxa Europe Moxa Asia Pacific Tel 49 89 3 70 03 99 0 Tel 886 2 8919 1230 Fax 49 89 3 70 03 99 99 Fax 886 2 8919 1231 Chapter 1 Chapter 2 Chapter 3 Chapter 4 Chapter 5 Chapter 6 Appendix A Appendix B Table of Contents Introductio iii ia 1 1 A O leds se tsscesSobstc e dln do E tle ctne 1 2 O A tants a5 oot EE 1 3 PEU ds totes e les A a tues 1 3 Package Checklist c atac to E hike rl to leds Merc o es ane chic tea a he 1 3 Installati n Flowchart et aa a e Ao 1 4 Hardware InstallatiON oo nnonnciccnnnnnnnnnnnnnnnrnnnrnn nna 2 1 CP 132U Series Block Dia grain conc riii in E E E E s 2 2 DIP S Witch Setting S ennienni n a a ee eee o E ee Mee E a 2 4 Plugging the Board into an Expansion Slot sssssssssseessseeeesseserseseesessteresseseesesersrsseeresseseessee 2 5 Software Installation iii ld ias 3 1 WiANdOWS DIT Vers usted be 3 2 Windows 20037X P ico aci a ltd beast 3 3 Windows 2000130 edad el ad ce lo DS teste 3 14 Windows Icod al 3 26 Windows Ni da e Dados aca meted 3 38 Non Windows DI Vers ca N aa E a ea E erste 3 45 DOS
20. 01Z3 0123456789abcde fghij0123456789abcde fghij0123456789abcde fghij01Z3 0123456789abede fghij0123456789abcde fghij0123456789abcde fghij01Z3 0123456789abcde fghij0123456789abede fghij0123456789abcde fghij01Z3 0123456789abcdefghij0123456789abcde fghij0123456789abcde fghij01Z3 0123456789abede fghij0123456789abcde fghij0123456789abcde fghij01Z3 State OPEN 2 m 0123456789abede fghij0123456789abcde fghij0123456789abcde fghij01Z3 0123456789abcde fghij0123456789abcde fghij0123456789abcde fghij01Z3 0123456789abcde fghij0123456789abcde fghij0123456789abcde fghij01Z23 0123456789abcdefghij0123456789abcdef y 4 gt State OPEN mm mu 7 RS 485 Programming If you are using your CP 132U Series board for RS 485 applications in addition to reading this section you should also refer to the Connection Cables and Cable Wiring chapter for more details about using RS 485 The CP 132U Series supports 2 wire half duplex RS 485 and 4 wire full duplex RS 485 communication Ports configured for 2 wire RS 485 use the Data and Data pins for both transmitting and receiving data Moxa s own ADDC Automatic Data Direction Control technology is used to switch between transmitting and receiving ADDC ADDC is the best method for switching between transmission and receiving when using 2 wire RS 485 When using ADDC additional code is not required to switch between data transmitting and
21. 25 pinout diagrams if you are using the Model M44M25x4 cable Male DB9 1 5 E o a 6 9 pin AS422 AwireRS 405 2wire R5485 TxD A TxD A TxD B TxD B RxD B RxD B Data B RxD A RxD A Data A GND GND GND RTS A RTS B 5 CTS B CTS A Cable Wiring RS 422 Point to point RS 422 Broadcasting CP 132UL RS 422 Device CP 132UL RS 422 Device 1 2 TxD B RxD B 2 TxD B 7 RxD B 1 TxD A RxD A 3 RxD B TxD B 3 RxD B TxD B 1 TxD A RxD A 4 RxD A TxD A 4 RxD A TxD A 5 GND GND 5 GND 4 GND RS 422 Device N RxDHB TxD B _ RxD A TxD A GND CP 132U Series User s Manual Pin Assignments CP 132UL RS 422 with Handshaking CP 132UL RS 422 Device 2 TxD B RxD B 1 TxD A RxD A 3 RxD B TxD B 4 RxD A TxD A 5 GND GND 7 RTS B CTS B 6 RTS A CTS A 8 CTS B RTS B 9 CTS A ____ RTS A CP 132UL 2 wire RS 485 CP 132UL RS 422 Device 3 Data B Datat B 4 Data A Data A 5 GND GND Multidrop 2 wire RS 485 half duplex CP 132UL RS 485 Device 1 Master Slave 3 Data Data 4 Data Data 5 GND GND Slave Ht Data Data GND Multidrop 4 wire RS 485 full duplex RS 485 Dev
22. 8 pure 32 bit Windows 95 98 virtual device port drivers VxD compliant with communication drivers VCOMM have been developed for the CP 132U and other Moxa multiport boards The drivers conform to the Win32 COMM API standard Installing the Driver for the First Time The following procedure shows how to install the CP 132U driver for the first time under Windows 98 First make sure the board or boards have already been plugged into the system s PCI or PCI X slot s NOTE If you have already installed a CP 132U or other Moxa Smartio Industio board in your computer and you install additional boards Windows 98 95 will automatically detect and install the new board s the next time you boot up the computer In this case proceed directly to the next section Configuring the Ports to configure the ports serial transmission parameters 3 26 CP 132U Series User s Manual Software Installation 1 After plugging the board into an expansion slot and powering on your PC Windows 98 will automatically detect the new board and display the Found New Hardware window When the Add New Hardware Wizard window opens click on Next to continue Add New Hardware Wizard 2 Select Display a list of all the drivers in a specific location so you can select the driver you want and then click on Next to proceed Add New Hardware Wizard 3 27 CP 132U Series User s Manual Software Installation 3 Select Other Devices and
23. A GND Connectors 2 DB9 male ports Optical isolation Max 2000V CP 132U I CP 132UL I V2 Surge protection ESD max 16000V CP 132UL CP 132U I CP 132UL V2 CP 132UL I V2 Termination Resistor 1200 Operating temperature 0 to 55 C Power requirement CP 132UL 220 mA 5V CP 132UL V2 120 mA 5V CP 132U I 578 mA 5V CP 132UL I V2 490 mA 5V Dimensions W x D CP 132UL 120 x 64 5 mm CP 132UL V2 120 x 64 5 mm CP 132U I 120 x 100 mm CP 132UL I V2 120 x 64 5 mm Operation Systems Windows 95 98 NT 2000 XP 2003 Linux DOS FreeBSD CP 132U Series User s Manual Technical Reference PCI The 32 bit CP 132UL Series board complies with PCI Specifications 2 1 and the IRQ and I O address hardware configuration is automatically assigned by the PCI BIOS This means that you must plug in the board before installing the driver As opposed to ISA slots different PCI slots in the same PC may have different bus numbers and device numbers with respect to the PCI specifications The same PCI board will have different system configurations if switched to a different PCI slot this is called slot sensitivity or slot dependency This may also apply to PCI slots in a PC with a different motherboard which may use different device number sets For example some use 17 18 19 and 20 for identifying the respective PCI slots but some use 11 12 13 and 14 Due to slot dependency it is ne
24. CP 132U Series User s Manual Industrial 2 Port RS 422 485 Serial Board for Universal PCI Bus Eighth Edition June 2008 www moxa com product MOXA 2008 Moxa Inc all rights reserved Reproduction without permission is prohibited CP 132U Series User s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement Copyright Notice Copyright 2008 Moxa Inc All rights reserved Reproduction without permission is prohibited Trademarks MOXA is a registered trademark of Moxa Inc All other trademarks or registered marks in this manual belong to their respective manufacturers Disclaimer Information in this document is subject to change without notice and does not represent a commitment on the part of Moxa Moxa provides this document as is without warranty of any kind either expressed or implied including but not limited to its particular purpose Moxa reserves the right to make improvements and or changes to this manual or to the products and or the programs described in this manual at any time Information provided in this manual is intended to be accurate and reliable However Moxa assumes no responsibility for its use or for any infringements on the rights of third parties that may result from its use This product might include unintentional technical or typographical errors Changes are periodically made to
25. CP 132UL I V2 CP 132U I V1 e PCI Boards C168H PCI C104H PCI C104HS PCI CP 114 CP 114I CP 114S CP 114 IS CP 132 CP 132I CP 132S CP 132IS e ISA Boards C168H C168HS C168P C104H C104HS C104P CI 104J CI 104JS CI 134 CI 134I CI 134IS CI 132 CI 132I CI 132IS e cPCI Boards CT 114I The overall procedure for installing the Windows drivers Plug the CP 132U series board into an for the CP 132U series boards is empty PCI or PCI X slot See the summarized in the flowchart at Hardware Installation chapter the right Note that except for Windows NT a newly installed board will be detected automatically by the Windows OS when it boots up Turn on your PC Windows will automatically detect the board except for Windows NT Driver already installed Install the driver from the Documentation and Software CD See the Installing the Driver for the First Time subsection for detailed instructions Configure the board s ports See the Configuring the Ports subsection for detailed instructions The CP 132U series board and ports are ready to use CP 132U Series User s Manual Software Installation Windows 2003 XP In this section we describe the installation procedure for Windows XP The installation procedure for Windows 2003 is similar Windows 2003 XP support up to 256 serial ports from COM1 to COM256 In order to utilize fully Windows 2003 XP s multi process multi thread advanced features pure 32
26. P 132U Series User s Manual Software Installation Configuring the Ports Follow the procedures given below to re configure the board s COM ports Since CP 132U is a Universal PCI board when a new board is added or an existing board is removed the board s configuration will be added or removed automatically by the operating system when you restart the PC 1 Open the Control Panel and the double click on the System icon 2 Select the Device Manager tab click on the desired CP 132U board under Moxa Smartio Industio multiport board to highlight it and then click on Properties System Properties x General Device Manager Hardware Profiles Performance View devices by type View devices by connection m Computer Y CDROM amp Disk drives a Display adapters 3 Floppy disk controllers Hard disk controllers F Keyboard g Monitors Y Mouse lt 9 Moxa Smartio Industio multiport board V TRES 89 Network adapters 4 Ports COM amp LPT El System devices H H Properties Refresh Remove Print Cancel 3 31 CP 132U Series User s Manual Software Installation 3 Basic information about the board is displayed on the General page Click on the Ports Configuration tab to configure the board s serial ports MOXA CP 118U Series PCI Bus Properties gt 21xj General Por
27. ally for troubleshooting under Windows 95 98 For general problems and solutions see the previous section General Troubleshooting 1 The system fails to find the CP 132U Series board The board s is are not plugged in properly The slot the boards are plugged into is defective Try another slot until you find one that works The board might be defective After the system reboots the error message CP 132U Series BusNo x DevNo x Portl COMx interrupt number is invalid appears This indicates that the Moxa board was found but the IRQ conflicts with another adapter Make sure the Moxa board s IRQ does not conflict with other adapters IRQ Check the PCI BIOS IRQ settings and select an available IRQ for Moxa boards 6 2 A Technical Reference Product Specifications Bus interface 32 bit PCI Number of ports 2 Max No of boards 4 T O address Assigned by PCI BIOS IRQ Assigned by PCI BIOS Comm controller Moxa UART 16C550C compatible Transmission speed 50 bps to 230 4 Kbps CP 132UL CP 132U D 50 bps to 921 6 Kbps CP 132UL V2 CP 132UL I V2 Data bits 5 6 7 8 Stop bits 1 1 5 2 Parity none even odd space mark Flow Control RTS CTS XON XOFF Connector Female DB25 Data signals RS 422 TxD B A RxD B A RTS B A CTS B A GND 4 wire RS 485 TxD B A RxD B A GND 2 wire RS 485 Data B
28. are already plugged into the system s PCI slot s l 2 Log into NT as Administrator Copy the Windows nt folder located under CP 132U Software WinNT on the Documentation and Software CD to your computer s hard disk under the C drive for example Open the Control Panel click on the Network icon and select the Adapters tab Click on Add and then Have Disk to open the Select Network Adapter window Specify the exact path and file name of the driver file C Windows nt in the example shown here and then click on OK to proceed Network 2 xi Identification Services Protocols Adapters Bindings Network Adapters 4 Select Network Adapter 2 x Click the Network Adapter that matches your hardware and then click OK IF umni hawe an installation disk far this enmnnnent click Insert Disk ay F Tht MMMA Ki ake ead nee m atime a91 e Insert disk with software provided by the software or hardware manufacturer If the files can be found at a different location for example on another drive type a new path to the files below Cancel ok Cancel OK Cancel 3 38 CP 132U Series User s Manual Software Installation 6 Select Moxa Smartio Industio Family multiport board in the Select OEM Option window and then click on OK to start installing the driver Select OEM Option Smartio Industio Family multiport board 7 The Moxa Smartio Industio Configuration Panel window
29. ate the Termination Resistors for ports 1 2 Open Termination Resistor is NOT active Short Termination Resistor is ACTIVE 2 2 CP 132U Series User s Manual Hardware Installation CP 132UL V2 120 x 64 5mm 120 mm 4 72 in 4 WIRE RS422 80 35 mm 3 16 in N gt E 2 N a oO 0 63 in _ 41 7 mm 1 64 in CP 132U V1 120 x64 5mm 13 24 mm 0 521 im L 120 00 mm 4 724 in A T pa q Z o o T O 1 U O o00000000000 0000000000000 64 41 mm 2 536 in 80 10 mm 3 154 in O mi P NY f l l one Y Y 46 00 mm 0 630 in le bes 10 20 mm 0 402 in 18 42 mm 0 725 in CP 132UL Series boards have four onboard DIP Switches referred to below as S1 1 S1 2 S2 1 and S2 2 that allow the user to choose one of three serial interfaces RS 422 RS 485 2 wire RS 485 4 wire for each of the two ports Note that S2 1 and S2 2 select between RS 422 and RS 485 and S1 1 and S1 2 select between 2 wire and 4 wire RS 485 S1 is only active when S2 is set to ON The figures on the following page show you how to use the switches to select one of the three serial interfaces for each of the board s two ports 2 3 CP 132U Series User s Manual Hardware Installation DIP Switch Settings Refer to the figures on the following two pages to see how to select between RS 422 RS 485 2 wire and RS 485 4 wire
30. bit Windows 2003 XP device drivers were developed for Moxa multiport boards The drivers conform to the Win32 COMM API standard Installing the Driver NOTE The following procedure shows how to install the CP 132U driver for the first time under Windows XP First make sure the board or boards have already been plugged into the system s PCI or PCI X slot s If you have already installed a CP 132U or other Moxa Smartio Industio board in your computer and you install additional boards Windows 2003 XP will automatically detect and install the new board s the next time you boot up the computer In this case proceed directly to the next section Configuring the Ports to configure the ports serial transmission parameters 1 After plugging the board into an expansion slot and powering on your PC Windows XP will automatically detect the new board and the Found New Hardware window will open in the bottom right corner of the Windows desktop i Found New Hardware x PCI Serial Port 2 The Welcome to the Found New Hardware Wizard window will open automatically Select Install from a list or specific location Advanced and then click on Next to continue Found New Hardware Wizard Welcome to the Found New Pea Hardware Wizard Y This wizard helps you install software for MOXA CP 118U Series PCI Bus f If your hardware came with an installation CD or floppy disk insert it now What do y
31. cessary to re configure the driver software once the board is plugged into different PCI slots Up to 4 CP 132U Series boards are allowed in one system When installing more than one board remember the order the boards are installed to distinguish the installed boards from each other Moxa UART The Moxa UART is an intelligent asynchronous controller that supports one full duplex channel that simultaneously transfers data at a transmission speed of 921 6 Kbps To increase overall data throughput special features such as on chip FIFO and on chip hardware flow control are used to reduce the number of interrupts to the onboard CPU helping to prevent data loss A 2
32. e change to all ports Cancel 3 41 CP 132U Tx FIFO Rx FIFO High 128 120 Middle 64 60 Low 1 1 Unit Bytes CP 132U Series User s Manual Software Installation 8 Click on OK to save the settings and then click on OK in the Property window to complete the port settings and return to the Moxa Smartio Industio Configuration Panel window The just configured CP 132U board will be listed as shown below Click on OK to return to the Network window G Moxa Smartio Industio Configuration Panel B000 9 Click on Close to close the Network window EF 6 MOXA Smartio Industio Family Adapter D Link DFE 530T PCI Fast Ethernet Adapter Rev A 10 Restart the PC to activate the new settings 3 42 CP 132U Series User s Manual Software Installation NOTE The driver configuration will NOT take effect until you restart the PC Using Event Log NOTE Once the system restarts you may check the event log recorded by the Moxa driver to verify that the board s ports have been initialized successfully To view the event log enter the Administrative group click the Event Viewer icon and then select Log and System to check a message similar to Moxa CP 132U board with first serial port COM has been enabled for each newly configured board If an error message similar to Cannot find any configured Moxa Smartio Industio seri
33. ed for DOS Linux and SCO DOS Moxa DOS API 232 is a software package that assists users in developing new programs or debugging existing programs for serial communications This section explains how to install the package how to set up the driver and how to load or unload the driver Moxa provides drivers that allow you to use the following serial board products under DOS Universal PCI Boards CP 118U CP 168U CP 104UL CP 104JU CP 102U CP 102UL CP 134U CP 134U I CP 132UL CP 132UL I V2 CP 132U I V1 PCI Boards C168H PCI C104H PCI C104HS PCI CP 114 CP 1141 CP 114S CP 114IS CP 132 CP 1321 CP 132S CP 13218 ISA Boards C168H C168HS C168P C104H C104HS C104P CI 104J CI 104JS CI 134 CI 1341 CI 134 IS CI 132 CI 132L CI 132IS cPCI Boards CT 114I1 Installing the Driver 1 Run the installation program DOSINST EXE from the Software DOS folder on the Documentation and Software CD Specify the target API 232 directory e g C Moxa to which the driver will be copied Press F2 to start the installation After the installation is complete a window will open to ask if you want to run SETUP EXE Press Y to run the program CP 132U Series User s Manual Software Installation Setting up the Driver This section covers some of the setup program s most frequently used functions For complete details press F1 to open the on line help file 1 Run BINSETUP EXE 2 Press Enter to select the
34. er Please install it The board is not properly plugged into the system If this is the case re plug the board into a 32 bit PCI slot It is also possible that a slot has malfunctioned In this case try other slots until you find one that works The motherboard does not have an available IRQ for the CP 132U Series board In this case enter the BIOS and make sure there is an available IRQ under PCI PnP settings The Moxa CP 132U board and driver are activated but cannot transfer transmit receive data Hardware Causes and Solutions a b Make sure the cable wiring is connected correctly Refer to the Pin Assignments chapter for correct cable connections The cable or the board could be defective Try other ports cables or boards to verify this or use the PComm Diagnostic utility to test the Moxa board and port conditions If Diagnostic reports an error replace the faulty components Software Causes and Solutions a CP 132U Series boards will check the line status CTS before transmitting data if the RTS CTS flow control feature is set to Enable in the configuration or application program Refer to the Connection Cables and Cable Wiring chapter for proper wiring diagrams and check the line status of the suspected port using the diagnostic LED indicators on the mini tester The board control application might not be written correctly according to the corresponding API of the operating system To check this prob
35. es board pops up refer to the Troubleshooting chapter for possible solutions Removing a CP 132U Board To remove a CP 132U board first shut down your PC and then physically remove the board from the PCI or PCI X slot The next time you start up the PC the system will automatically remove the configuration for the board You do not need to click the Remove button in the Moxa Smartio Industio Configuration Panel 3 43 CP 132U Series User s Manual Software Installation Removing the Driver To remove the CP 132U driver 1 Open the Control Panel click on the Network icon and select the Adapters tab 2 Click on Moxa Smartio Industio Family Adapter in the Network Adapters list to highlight it 3 Click on Remove Network 27 xi Identification Services Protocols Adapters Bindings Network Adapters 8 2 D Link DFE 530TX PCI Fast Ethemet Adapter Rev A lt 4 Smartio Industio Family Adapter Add Remove _Bropertes Update ltem Notes MOXA Smartio Industio Family Adapter 4 Click on Close and then restart the system Updating the Driver To update the CP 132U driver 1 Remove the current driver see the previous subsection for instructions 2 Restart the system 3 Install the new driver Refer to the Installing the Driver for the First Time section for instructions 3 44 CP 132U Series User s Manual Software Installation Non Windows Drivers Drivers are provid
36. es cia dene B 1 Moxa Internet Services s it AD BH A B 2 Problem Report Forman de ahaa Garde tie RRA eee ae GABA SAAS B 3 Product Return Procedure 1 Introduction Moxa s CP 132UL series Universal PCI serial board meets the new slot standard for expansion boards and works with both 3 3V and 5V PCI slots The board has eight independent 422 485 serial ports for connecting data acquisition equipment and other serial devices to a PC The following topics are covered in this chapter O Overview Applications Features Package Checklist Installation Flowchart DODO CP 132U Series User s Manual Introduction Overview Smartio The Smart Multiport Async Solution CP 132U Series is one of the newest members of Moxa s well known Smartio series of multiport serial boards in which Smartio stands for Smart Multiport serial I O solution The 2 port 422 485 CP 132U board is designed for the plug and play 32 bit PCI bus and is an economical solution for connecting terminals modems printers scanners cash registers bar code readers keypads numeric displays electronic scales data acquisition equipment and many other serial devices for the PC and compatible systems The Smartio device driver makes full use of the 128 byte Tx Rx FIFO and on chip H W and S W flow control Your applications will be capable of transmitting data without loss at speeds as high as 921 6 Kbps providing a reliable high performance solution for mu
37. evels of High Middle and Low are available with the default set to High 128 bytes Check Set the change to all ports checkbox to apply the just defined Tx FIFO Size to all ports CP 132U Port Number COM3 current TA J Auto Enumerating COM Number Te Low 1 1 Rx FIFO Level High y Unit Bytes JV Set the change to all ports Ix FIFO Level High y JV Set the change to all ports Came 9 Click on OK to save the port settings and then click on OK in the Property window to finish the port settings procedure Updating the Driver This section explains how to update the Windows 98 driver 1 Open the Control Panel click on the System icon and select the Device Manager tab 3 33 CP 132U Series User s Manual Software Installation 2 Click on a Moxa CP 132U board under Moxa Smartio Industio multiport board to highlight it and then click on Properties System Properties Floppy disk controllers 2 Hard disk controllers 3 Select the Driver tab and click on Update Driver CP 118U Series Properties x 3 34 CP 132U Series User s Manual Software Installation 4 Click on Next Update Device Driver Wizard 5 Select Display a list of all the drivers in a specific location so you can select the driver you want and then click on Next 3 35 CP 132U Series User s Manual Software Installation 6 In the next
38. fully 3 19 CP 132U Series User s Manual Software Installation Configuring the Ports After the driver has been installed use Device Manager to configure the CP 132U serial ports 1 Click on Start gt Settings gt Control Panel gt System select the Hardware tab and then click on Device Manager System Properties 3 20 CP 132U Series User s Manual Software Installation 2 Expand the Multi port serial adapters tab right click on Moxa CP 132U Series PCI Bus and then click on Properties to open the board s configuration panel Zoevice Manager File Action View Help A e E gt Keyboards T5 Mice and other pointing devices Monitors 2 3 Multi port serial adapters a MOXA CP 118U Series PCI Bus S Network adapters Update Driver 4 Ports COM amp LPT Disable y Communicatic Uninstall Communicatic 4 MOXA Comm Sean For hardware changes SAIN Properties O A MOXA Comm MOXA Communication Port 4 COM6 4 MOXA Communication Port 5 COM 4 MOXA Communication Port 6 COM8 4 MOXA Communication Port 7 COM9 A MOXA Communication Port 8 COM10 4 Printer Port LPT1 SB Processors Sound video and game controllers W System devices Opens property sheet For the currer 3 Basic information about the board is displayed on the General page Click on the Ports 3 21 CP 132U Series User s Manual Software Installat
39. he setup procedure run BIN DP DRV EXE from the DOS prompt to load the driver The driver will automatically detect the boards that have already been installed If one or more board is detected you will see a message similar the following Smartio Industio Family DOS driver Version 1 5 Setup driver CP 132U series Bus x Dev y OK Device driver setup O K This means that the CP 132U Series driver has been installed properly At this point you may execute applications that support API 232 functions or start developing applications using the API 232 library Unloading the Driver To unload release the driver from memory type DP DRV Q at the DOS prompt and then press Enter Linux Moxa provides drivers that allow you to use the following serial board products under Linux e Universal PCI Boards CP 118U CP 168U CP 104UL CP 104JU CP 102U CP 102UL CP 134U CP 134U I CP 132UL CP 132UL I V2 CP 132U I V1 e PCI Boards C168H PCI C104H PCI C104HS PCI CP 114 CP 1141 CP 114S CP 114IS CP 132 CP 1321 CP 132S CP 132IS e ISA Boards C168H C168HS C168P C104H C104HS C104P CI 104J CI 104JS CI 134 CI 134I CI 134IS CI 132 CI 132I CI 132IS e CPCI Boards CT 114I 3 48 CP 132U Series User s Manual Software Installation Execute the following commands from the Linux prompt 1 mount dev cdrom mnt cdrom cd mkdir moxa cd moxa cp mnt cdrom lt driver directory gt mxser tgz
40. ice N CP 132UL RS 485 Device 1 Master Slave 2 TxD B RxD B 1 TxD A RxD A 3 RxD B TxD B 4 RxD A TxD A 5 GND GND Slave DE RxD B HIT RxD4A TxD B grn TxD A oa GND RS 485 Device N See the section RS 485 Programming in the Serial Programming Tools chapter for more details on RS 485 programming 5 4 CP 132U Series User s Manual Pin Assignments Impedance Matching and Termination Resistors When using RS 422 485 serial communications an electrical signal that travels through two different resistance junctions in a transmission line will sometimes give rise to signal reflection due to the impedance mismatch Signal reflection causes signal distortion which in turn contributes to communication errors The solution to this problem is to establish the same impedance at the ends of the transmission line as in the line itself by terminating the ends of the line with resistors 5 5 6 Troubleshooting Common CP 132U Series problems and possible solutions are listed below If you still have problems after reading this chapter contact your dealer or Moxa for help or use the Problem Report Form at the end of this manual to report problems to your dealer General Troubleshooting 1 The Moxa CP 132U board cannot be detected by the Moxa driver while installing the driver Hardware causes and solutions a b The board is not installed in the comput
41. ion 4 Configuration tab to configure the board s serial ports MOXA CP 118U Series PCI Bus Properties General Ports Configuration Driver Resources E MOXA CP 118U Series PCI Bus Device type Multi port serial adapters Manufacturer Moxa Technologies Inc Location PCI Slot 2 PCI bus 0 device 10 function 0 r Device status This device is working properly If you are having problems with this device click Troubleshoot to start the troubleshooter Ez Device usage Use this device enable y 5 Click on the port you would like to configure to highlight it and then click on Port Setting MOXA CP 118U Series PCI Bus Properties General Ports Configuration Driver Resources Rx FIFO Level Tx FIFO Level Help Port Info dl Port Setting 3 22 CP 132U Series User s Manual Software Installation 6 Select a COM number for the port from the Port Number pull down list 7 Check the Auto Enumerating COM Number checkbox to map subsequent ports automatically The port numbers will be assigned in sequence For example if COM 3 is assigned to Port 1 then COM 4 if not already occupied will be assigned to Port 2 etc 8 Select an Rx FIFO Trigger from the Rx FIFO Level pull down list Rx FIFO trigger levels of High Middle and Low are available with the default set to High 120 bytes Check Set the change to all ports checkbox
42. lem run another application that you know is correct or use the utilities provided by Moxa such as Pcomm Terminal emulator or HyperTerminal under Windows NT and Windows 95 98 CP 132U Series User s Manual Troubleshooting Windows NT This section is specifically for troubleshooting problems for Windows NT For general problems and solutions see the previous section General Troubleshooting 1 After the system reboots the error message Another driver in the system which did not report its resources has already claimed the interrupt used by xxx appears in the Event Log This indicates the Moxa board was found but the IRQ is conflicting with another adapter Check the PCI BIOS IRQ settings first and then select an IRQ that is available After the system reboots the error message Cannot find any configured Moxa Smartio Industio Series board appears in the Event Log Make sure the PCI board is seated firmly in the expansion slot The COM number of the CP 132U Series conflicts with others The COM numbers of different boards happen to be the same Try changing the COM number mappings Windows NT system panic blue screen This could be caused by an IRQ or memory conflict with other ISA Bus adapters such as LAN and SCSI boards or the system BIOS Refer to the corresponding problem in the previous section General Troubleshooting for possible solutions Windows 95 98 This section is specific
43. ltiport serial communications PCI Solution The CP 132U series board complies with PCI Spec 2 1 The serial transmission mode RS 422 2 wire RS 485 or 4 wire RS 485 for each port is set with onboard switches but the ports transmission parameters are configured after the board is installed The IRQ and I O addresses are assigned automatically by the PCI BIOS For this reason the board MUST be plugged into the computer before installing the driver For more PCI information refer to the Technical Reference appendix Surge Protection The CP 132U series board comes with built in 15 KV ESD surge protection to prevent damage to the board from lightning or high potential voltage The surge protection feature makes the CP 132U board suitable for industrial factory type applications and for use with applications that are subject to severe weather conditions ADDC Automatic Data Direction Control for RS 485 To make 2 wire RS 485 half duplex connections easier to manage ADDC Automatic Data Direction Control intelligence is built into the CP 132U series board eliminating the need for software interference This means that Windows applications can be set up to manage RS 485 ports without writing additional code to control the half duplex protocol Operating System Support The CP 132U series board is compatible with all major industrial platforms including Windows 2000 XP 2003 Windows NT Windows 95 98 Me DOS and Linux Moxa
44. mination Resistors CP 132U Series User s Manual Pin Assignments Board Side Pin Assignments Female DB25 The RS 422 standard uses a balanced voltage digital interface to allow 9600 bps communication over cables of up to 4000 feet in length Ten receivers can be connected to any one driver for broadcasting systems The RS 485 standard is an enhanced version of the RS 422 balanced line standard It allows multiple drivers and receivers to work on a multidrop network A maximum of 32 drivers and 32 receivers can be set up on a multidrop network The CP 132UL Series supports both 2 wire half duplex and 4 wire full duplex RS 485 communications In 2 wire RS 485 Data pins are used for both data transmitting and receiving depending on the RTS signal 45 17 549 121 23 125 See ee0e0e0808000860 0 ee 0o ee Ce Oe ee I pp pe po po y 3 5 7 9 11 413 Port 2 Port1 CP 132UL RS 422 4 wire RS 485 CP 132U 2 wire RS 485 Port 1 Port 2 Port 1 Port 2 RxD B 12 18 Data B 12 TxD B 24 5 Data A 9 RTS B 11 17 CTS B 23 4 RxD A 9 15 RTS A 10 16 TxD A 21 2 CTS A 8 14 SGND 22 3 5 2 CP 132U Series User s Manual Pin Assignments Device Side Pin Assignments In this subsection we give the pinouts for individual ports Refer to the DB9 pinout diagrams if you are using the Model M44M9x4 cable and refer to the DB
45. model name of the Moxa board you are installing 3 A window will open displaying basic configuration information for all boards of this type currently installed in the system Press PgDn to configure the port settings CP 132U Series User s Manual Software Installation 4 You may enter or modify the settings of each port at this stage The values displayed first are the port s initial values that were set up when the driver was installed 5 Press F10 to save the changes and exit the SETUP program Legends In this section we explain the meaning of some of the fields and functions Port number This is the ID of the port Application software uses port number ID when referring to a port Port numbers can be set to any number between 0 and 255 inclusive However you must ensure that each port is assigned a unique port number If you are developing your own application software then you may want to select port numbers that take into consideration the structure of the program TxD buffer size The TxD buffer is the transmission output buffer allocated by the system for each port RxD buffer size The RxD buffer is the receiving input buffer allocated by the system for each port 3 47 CP 132U Series User s Manual Software Installation F5 Group Edit This is a convenient function that allows you to edit the configuration of several ports at one time as a group Loading the Driver After completing t
46. nd configure the board and ports Chapter 3 Software Installation Connect the serial devices to the CP 132U Chapter 5 Pin Assignments board s serial ports Restart the system and check the driver i initialization status Chapter 3 Software Installation Develop and run your serial aes 43 communication applications Chapter 4 Serial Programming Tools 2 Hardware Installation The CP 132U series hardware installation procedure is described in this chapter Since the CP 132U series board s IRQ number and I O addresses are assigned automatically by the PCI BIOS the board MUST be plugged in before installing the driver The following topics are covered in this chapter U CP 132U Series Block Diagram U DIP Switch Settings OU Plugging the Board into an Expansion Slot CP 132U Series User s Manual Hardware Installation CP 132U Series Block Diagram CP 132U Series boards IRQ number and I O address are assigned automatically by the PCI BIOS This means that the board MUST be plugged in first before installing the driver CP 132UL I V2 120 x 64 5 mm 120 mm 4 72 in S1 2 2 WIRE _RS485 80 35 mm 3 16 in E E N gt gt N o Y o O 0 63 in 1 64 in CP 132UL I V1 120 x100mm 120 mm TTL to Serial Signal Zone a JP1 Isolation Modules 121 mm DC to DC Power Converter PCI ISA Bridge NOTE Use JP1 2 to activ
47. ns Hardware Profiles OK Cancel Apply 3 9 CP 132U Series User s Manual Software Installation 2 Expand the Multi port serial adapters tab right click on Moxa CP 132U Series PCI Bus and then click on Properties to open the board s configuration panel Device Manager gt Keyboards Mice and other pointing devices Monitors Multi port serial adapters SF MOXA Communication Port 5 COM a MOXA Communication Port 6 COM8 xd MOXA Communication Port 7 COM9 J MOXA Communication Port 8 COM10 4 Printer Port LPT1 M Processors b Sound video and game controllers fH WY System devices 3 Click on the port you would like to configure to highlight it and then click on Port Setting MOXA CP 118U Series PCI Bus Properties COM 3 on OO amp 10 N ee 3 10 CP 132U Series User s Manual Software Installation 4 Select a COM number for the port from the Port Number pull down list 5 Check the Auto Enumerating COM Number checkbox to map subsequent ports automatically The port numbers will be assigned in sequence For example if COM 3 is assigned to Port 1 then COM 4 if not already occupied will be assigned to Port 2 etc 6 Select an Rx FIFO Trigger from the Rx FIFO Level pull down list Rx FIFO trigger levels of High Middle and Low are available with the default set to High 120 bytes Check Set the change to all ports checkbox to apply this R
48. ou want the wizard to do C Install the software automatically Recommended 3 Select Search for the best driver in these locations check Include this location in the search and then click on Browse Navigate to the CP 132U Software Win2K XP 2003 3 3 CP 132U Series User s Manual Software Installation folder on the software CD and then click on Next to continue Found New Hardware Wizard Please choose your search and installation options SS Y Search for the best driver in these locations Use the check boxes below to limit or expand the default search which includes local paths and removable media The best driver found will be installed J Search removable media floppy CD ROM IV Include this location in the search JH ACP 118U1Softwarewin2K lt P 2003 X C Don t search will choose the driver to install Choose this option to select the device driver from a list Windows does not guarantee that the driver you choose will be the best match for your hardware lt Back Next gt Cancel 4 Wait while the installation wizard searches The next window that opens cautions you that although this software hasn t passed Windows Logo testing the driver has been tested and shown that it can support the Windows OS Click on Continue Anyway to proceed Found New Hardware Wizard ma Please wait while the wizard installs the software SS Y Sap MOXA CP 118U Series PCI Bus
49. program allows the user to check the function of both software and hardware To run the Diagnostic program click on Start gt Program gt PComm Lite gt Diagnostic A typical test report for a Moxa board is shown below BS PComm Diagnostic MES File Diagnose Help e gt ae TES E ln CP 168U Series COM3 COM10 JCP 168U Series Dev 0 Bus 0 IRO 5 1 0 B400 K Dev 0 Bus 0 RQ 5 1 0 B400 Communication Parameter 38400 None 8 1 Driver Version 5 7 OS Version Windows 4 10 Build 2222 Internal Loopback Te Ready 4 3 CP 132U Series User s Manual Serial Programming Tools Monitor for Moxa boards under Windows NT 2000 XP 2003 This useful port status monitoring program allows you to monitor data transmission of selected Moxa COM ports The program monitors data transmission receiving throughput and communication line status with data updated and displayed on the screen at regular time intervals Click on a specific port to see a graph of the current communication parameters and status of that port To run the Monitor program click on Start gt Program gt Pcomm Lite gt Monitor 3 PComm Monitor ax Port Count Tx CP3 Tx Count Rx CPS Rx RTS CTS DTR DSR DCD 126976 126976 125952 125952 126300 125952 126032 128000 1032 125828 1014 126976 12 3 126976 125440 0 125264 126976 126760 COMS Port Status m Tx bytes 1s Tx History
50. rm msterm 3 49 4 Serial Programming Tools Moxa provides an easy to use yet powerful serial programming library and communication troubleshooting utilities under Windows 2000 XP 2003 Windows 95 98 and Windows NT The following sections give details about the installation the library and the utilities for various platforms The following topics are covered in this chapter U Moxa PComm gt Installing PComm gt PComm Programming Library Q Utilities gt Diagnostic for Moxa boards only gt Monitor for Moxa boards under Windows NT 2000 XP 2003 gt Terminal Emulator Q RS 485 Programming gt ADDC CP 132U Series User s Manual Serial Programming Tools Moxa PComm PComm a professional serial comm tool for PCs is a software package that runs under Windows NT 2000 XP 2003 95 98 PComm provides e A powerful serial communication library that simplifies serial programming tasks for most popular programming languages The serial communication library is useful for developing applications for data communications remote access data acquisition and industrial control under Windows NT 2000 XP 2003 95 98 and is a simpler programming solution compared to the more complex Windows Win32 COMM API e Useful utilities such as diagnostic monitor and terminal emulator e Illustrative sample programs e Comprehensive on line documentation Installing PComm To install PComm run Setup exe from the Documentation
51. rt 0 Click Finish to close the wizard lt Back 12 Repeat Step 7 through Step 11 for each of the remaining seven ports The last port to be installed will be Moxa Port 7 as shown in the following figure Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for F MOXA Port 7 pe Click Finish to close the wizard lt Back 3 8 CP 132U Series User s Manual Software Installation 13 The Found New Hardware pop up window will reappear to inform you that the hardware was installed successfully i Found New Hardware x Your new hardware is installed and ready to use Configuring the Ports After the driver has been installed use Device Manager to configure the CP 132U serial ports 1 Click on Start gt Settings gt Control Panel gt System select the Hardware tab and then click on Device Manager System Properties 21x System Restore Automatic Updates Remote General Computer Name Hardware Advanced r Add Hardware Wizard E The Add Hardware Wizard helps you install hardware Add Hardware Wizard M Device Manager eri The Device Manager lists all the hardware devices installed on your computer Use the Device Manager to change the properties of any device Driver Signing r Hardware Profiles ca Hardware profiles provide a way for you to set up and store different hardware configuratio
52. then click on Next to proceed Add New Hardware Wizard Mouse Multi function adapters MultilOController Network adapters Other detected devices Other devices PCMCIA socket Ports COM amp LPT Printer SBP2 SCSI controllers 4 Click on Have Disk Add New Hardware Wizard Unsupported Device 5 Use the Browse button to navigate to the CP 132U Software Win9x Windows 95 folder on the Documentation and Software CD and then click on OK Install From Disk pa E HACP 118U4Softwarevwin9x Windows 3 28 CP 132U Series User s Manual Software Installation 6 Click on CP 132U Series 8 23 2004 to highlight it and then click on Next Add New Hardware Wizard O CP 118U Series 8 23 2004 7 Verify that the CP 132U Series driver will be installed and then click on Next 3 29 CP 132U Series User s Manual Software Installation 8 Basic configuration information will be displayed in the CP 132U Series Installation window Click on OK to complete the installation of the board CP 118U Series Installation Je iin Vector 0o w Md Pwr Se High 9 This completes the installation of the CP 132U board Click on Finish to exit the Add New Hardware Wizard Add New Hardware Wizard NOTE If an error message similar to CP 132U board BusNo x DevNo x Portl COMx interrupt number is invalid pops up refer to the Troubleshooting chapter for solutions 3 30 C
53. to apply this Rx FIFO Trigger to all ports 9 Select a Tx FIFO Level from the Tx FIFO Level pull down list Tx FIFO Levels of High Middle and Low are available with the default set to High 128 bytes Check Set the change to all ports checkbox to apply the just defined Tx FIFO Size to all ports Port Number COM3 current J Auto Enumerating COM Number Rx FIFO Level High y JV Set the change to all ports Ix FIFO Level High y V Set the change to all ports Cane CP 132U Tx FIFO Rx FIFO High 128 120 Middle 64 60 Low 1 1 Unit Bytes 10 Click on OK to save the port settings and then click on OK in the Property window to finish the port settings procedure 3 23 CP 132U Series User s Manual Software Installation Using Moxa PComm Utility The PComm Diagnostic program is a useful tool for checking the status of Moxa s multiport boards The program can be used to test internal and external IRQ TxD RxD UART CTS RTS DTR DSR etc Use this program to ensure that your Moxa boards and ports are working properly To start the program click on Start gt Programs gt PComm Lite 2000 XP Ver 1 2 gt PComm Diagnostic amp jpcomm Diagnostic E File Diagnose Help en Blaj To be tested NEO Seis COM x Devii 10 Busti 0JRQ Selec kta xl Selec CP 118U Series COM3 COM10 Dev 10 Bus 0 RQ 9 1 0 B000
54. to configure the port 3 40 CP 132U Series User s Manual Software Installation Property x 1 WT vector soo Interrupt No 11 Y Base I O Port Address 000 Board Type fcr 1 18U Series Bus Dev 0 0 Port COM No Rx FIFO Level Tx FIFO Level COM4 High High coms High High COMB High High COM High High coma High High COM9 High High COMO High High 0 Y m2 Y mi Help Port Info Port seting oma 4 Select a COM number for the port from the Port Number pull down list 5 Check the Auto Enumerating COM Number checkbox to map subsequent ports automatically The port numbers will be assigned in sequence For example if COM3 is assigned to Port 1 then COMA if not already occupied will be assigned to Port 2 etc 6 Select an Rx FIFO Trigger from the Rx FIFO Level pull down list Rx FIFO trigger levels of High Middle and Low are available with the default set to High 120 bytes Check Set the change to all ports checkbox to apply this Rx FIFO Trigger to all ports 7 Select a Tx FIFO Level from the Tx FIFO Level pull down list Tx FIFO Levels of High Middle and Low are available with the default set to High 128 bytes Check Set the change to all ports checkbox to apply the just defined Tx FIFO Size to all ports Port Number COM3 current IV Auto Enumerating COM Number Rs FIFO Level High y JV Set the change to all ports Tx FIFO Level High y JV Set th
55. ts Configuration Driver Resources E MOXA CP 118U Series PCI Bus Device type Multi port serial adapters Manufacturer Moxa Technologies Inc Location PCI Slot 2 PCI bus 0 device 10 function 0 r Device status This device is working properly If you are having problems with this device click Troubleshoot to start the troubleshooter i Troubleshoot Device usage Use this device enable y 4 Click on the port you would like to configure to highlight it and then click on Port Setting MOXA CP 118U Series PCI Bus Properties q ax General Ports Configuration Driver Resources Ax FIFO Level Tx FIFO Level Help Port Info dl Port Setting 3 32 CP 132U Series User s Manual Software Installation 5 Select a COM number for the port from the Port Number pull down list 6 Check the Auto Enumerating COM Number checkbox to map subsequent ports automatically The port numbers will be assigned in sequence For example if COM3 is assigned to Port 1 then COM4 if not already occupied will be assigned to Port 2 etc 7 Select an Rx FIFO Trigger from the Rx FIFO Level pull down list Rx FIFO trigger levels of High Middle and Low are available with the default set to High 120 bytes Check Set the change to all ports checkbox to apply this Rx FIFO Trigger to all ports 8 Select a Tx FIFO Level from the Tx FIFO Level pull down list Tx FIFO L
56. window the CP 132U Series option should already be highlighted Click on Have Disk and then navigate to the folder that contains the new driver file Update Device Driver Wizard CP 104JU Series CP 118U Series CP 13411 Series 7 Follow the on screen instructions to complete the driver update procedure 3 36 CP 132U Series User s Manual Software Installation Removing the Driver This section explains how to remove the CP 132U driver 1 Open the Control Panel double click on the Add Remove Programs icon and then select the Install Uninstall tab 2 Click on the Moxa Smartio Industio Driver option and then click on Add Remove to start the driver removal process Add Remove Programs Properties 3 Click on Yes to confirm that you want to remove the driver MOXA Smartio Industio Driver 7 4 Click on OK MOXA Smartio Industio Driver 3 37 CP 132U Series User s Manual Software Installation Windows NT Windows NT supports up to 256 serial ports from COM1 to COM256 To utilize fully Windows NT s multi process and multi thread advanced features pure 32 bit Windows NT device drivers were developed for the CP 132U boards and other Moxa multiport boards The drivers conform to the Win32 COMM API standard Installing the Driver for the First Time The following procedure explains how to install the Smartio CP 132U driver for the first time First make sure the board or boards
57. window that opens cautions you that although this software hasn t passed Windows Logo testing the driver has been tested and shown that it can support the Windows OS Click on Continue Anyway to proceed Please wait while the wizard installs the software y MOXA Port 0 Hardware Installation N The software you are installing for this hardware e MOXA Port 0 LA has not passed Windows Logo testing to verify its compatibility with Windows XP Tell me why this testing is important Continuing your installation of this software may impair or destabilize the corect operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing 10 Wait while the wizard installs the software Found New Hardware Wizard 4 Please wait while the wizard installs the software SS y MOXA Port 0 ic 7 a serenum sys To FAWINXPAS ystem32ADRIVERS 3 7 CP 132U Series User s Manual Software Installation 11 After all files have been copied to the system the Completing the Found New Hardware Wizard window will open to indicate that it has finished installing Port 0 Click on Finish to proceed with the rest of the installation Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for F MOXA Po
58. x FIFO Trigger to all ports 7 Select a Tx FIFO Level from the Tx FIFO Level pull down list Tx FIFO Levels of High Middle and Low are available with the default set to High 128 bytes Check Set the change to all ports checkbox to apply the just defined Tx FIFO Size to all ports Port Number COM3 current J Auto Enumerating COM Number Ax FIFO Level High y JV Set the change to all ports Tx FIFO Level High y V Set the change to all ports Cca CP 132U Tx FIFO Rx FIFO High 128 120 Middle 64 60 Low 1 1 Unit Bytes 8 Click on OK to save the port settings and then click on OK in the Property window to finish the port settings procedure CP 132U Series User s Manual Software Installation Using Moxa PComm Utility The PComm Diagnostic program is a useful tool for checking the status of Moxa s multiport boards The program can be used to test internal and external IRQ TxD RxD UART CTS RTS DTR DSR etc Use this program to ensure that your Moxa boards and ports are working properly To start the program click on Start gt Programs gt PComm Lite 2000 XP Ver 1 2 gt PComm Diagnostic amp jpcomm Diagnostic E File Diagnose Help en Blaj To be tested CFTR Seis COM x Devii 10 Busti 0JRQ Selec kta xl Selec CP 118U Series COM3 COM10 Dev 10 Bus 0 RQ 9 1 0 B000 Driver 1 9 0
59. xa multiport boards The drivers conform to the Win32 COMM API standard Installing the Driver for the First Time The following procedure shows how to install the CP 132U driver for the first time under Windows 2000 First make sure the board or boards have already been plugged into the system s PCI or PCI X slot s NOTE If you have already installed a CP 132U or other Moxa Smartio Industio board in your computer and you install additional boards Windows 2000 will automatically detect and install the new board s the next time you boot up the computer In this case proceed directly to the next section Configuring the Ports to configure the ports serial transmission parameters 3 14 CP 132U Series User s Manual Software Installation 1 After plugging the board into an expansion slot and powering on your PC Windows 2000 will automatically detect the new board and the Found New Hardware window will open Found New Hardware A PCI Serial Port Installing 2 When the Welcome to the Found New Hardware Wizard window opens click on Next to continue Found New Hardware Wizard Welcome to the Found New py Hardware Wizard SS This wizard helps you install a device driver for a hardware device To continue click Next 3 15 CP 132U Series User s Manual Software Installation 3 Select Search for a suitable driver for my device recommended and then click on Next to continue