1. 6 digits code one time One Beep sounds which indicates the entry is valid d Re enter the new six 6 digits code One Beep sounds which indicates the codes entered in steps c and d are the same and the code chang ing process is successful e If Three Beeps sound the changing process fails The existing code is still valid Repeat steps a to d Note a Verify the new code at least 3 times before 3
2. FEATURES 1 Manufacturer default 1 2 3 4 5 6 2 Function of Code 3 a Unlock b Change code Wrong Entry Penalty Entry of four 4 consecutive invalid codes results in a 5 minute delay period i The unit beeps at 5 second intervals ii During delay period removing batteries the entry pad stops counting time reinstalling bat teries the entry pad continues to count down until 5 minutes delay period finishes Standby Status The entry pad will turn into a standby status with a long beep sound if there is no operation in 10 sec onds after the system is activated 5 Automatic Re lock The entry pad will re lock in 4 seconds after a valid entry is made and the door is open Low Battery Alert a Entry pad repeated beeping during an unlocking indicates that the battery is low and needs imme diate replacement b Manufacturer recommends the use of 9 Volt pre mier alkaline batteries and an annual maintenance replacement of the batteries 2 USER OPERATING INSTRUCTIONS 1 ALWAYS PERFORM OPERATIONS WITH THE ENTRY PAD UNLOCK 2 Before closing the door make sure all the changes are correct 3 Do not set the user code to six 0 1 Change Code a Enter 0 six times One Beep sounds which indicates the entry is valid and the system is awaiting the code changing b Enter the existing six 6 digits code one time One Beep sounds which indicates the entry is valid c Enter a new six
3. closing the door to make sure the code is cor rect b Operations between adjacent steps need be fin ished in 10 seconds Otherwise the system sets back to standby status Specifications Power Supply DC 9V Power Supply Range DC 4 5V 12V Standby Current lt 15yA Active Current lt 20mA Battery Low Voltage 5 2 0 2V Working Temperature 0 C 49 C Working Humidity max lt 90 Password Length 6 Digits Mechanical System Life Span gt 10 000 Cycles evaluated by UL gt 100 000 Cycles not evaluated by UL SecuRam Systems Inc U S A 4 Doc No ECSL0601A071109 Version No V2 0020090209 E TTRAM Operating and Installation Instructions Model ECSL 0601A Electronic Combination Controller ATTENTIONS e For indoor use only e Battery Low Voltage 5 2 0 2V The display will alert low battery when battery voltage reaches 5 2 0 2V PLEASE REPLACE THE BATTERY IMMEDI ATELY Battery Replacement Instructions 1 In the back of Entry Pad you will see one 9 V alkaline battery Take the battery out of the battery compart ment Gently pull on the battery until it drops out 2 Gently remove the connector by unsnapping it from the two terminals on the top of the battery Never Pull on the Battery Leads 3 Connect a new 9V Alkaline battery to the battery clip 4 Put the battery and the leads completely back into the battery compartment e Mounting and wiring refer to the instruction in this manual

Download Pdf Manuals

image

Related Search

Related Contents

MD400 Scanner Pocket Service Guide  Mode d`utilisation de SoundCloud 1- Il faut tout d`abord t`enregistrer  SICONGIS  Jumelles 10x50 Mode d`emploi  Philips 105S20 Computer Monitor User Manual  Philips HD5407  mode d`emploi du site du SEL Gabare  User Manual Inclination Sensors with CANopen Interface  

Copyright © All rights reserved.
Failed to retrieve file