Home
User Manual XGRIP N08QI
Contents
1. 26 1 sleeve 27 1 protective sleeve 28 1 Pin cylindrical 4 0 x 10 29 1 compression spring 30 1 compression spring 31 1 rear screwed joint 32 1 ring for compression spring 33 1 muffler 34 1 push button 35 1 lip seal 22 12 7 pneumatic plunger rod 36 1 guide ring 37 1 bottom ring 38 1 pneumatic plunger 39 1 pneumatic cylinder 40 1 cover ring 12 User Manual XGRIP NO8QI bottle with oil 30 cc 41 1 o ring 14 2 42 1 o ring 82 62 3 52 pneumatic plunger 43 1 coupling for pressure gauge 44 1 o ring 10 1 5 45 1 pressure gauge 46 1 oil level indicator 47 1 o ring 10 1 5 48 1 pressure relief valve 49 1 pressure regulation valve 50 2 o ring 18 1 5 51 1 retaining ring 6 DIN 471 52 1 Pression regulation screw 53 1 Covering 54 1 retaining ring 55 1 bottom ring 56 1 union coupling 90 57 2 connecting bolt 58 2 copper washer for connecting bolt 59 2 M6 cap nut for connecting bolt 60 1 bolt below valve pin 61 1 o ring 4 2 valve pin 62 1 sleeve for needle valve 63 1 muffler 64 2 o ring 4 2 65 3 Adjusting ring diameter 14 66 3 o ring 10 2 67 1 valve pin 68 1 Pin cylindrical 3 0 x 20 69 1 eccentric trigger 70 1 trigger 71 1 o ring 4 1 valve pin 72 1 Needle valve for time of return 73 1 cap screw M6 x 16 74 1 o ring 4 2 2 valve pin 75 1 o ring 30 2 77 1 compression spring valve pin 78 1 o ring 7 1 2 1 oil syringe 1 1 size 3 mm Allen key 13 User Manual XGR
2. completed on purchase and sent to Masterfix Products B V This Masterfix XGRIP NO8QI riveter Nr was sold to Stamp address buyer Stamp address vendor Date Signature of sales person 15 User Manual XGRIP NO8QI EC DECLARATION OF CONFORMITY FOR MACHINERY We MASTERFIX PRODUCTS BV EUROPE Europalaan 12 6199 AB Maastricht Airport The Netherlands herewith declare that the product type XGRIP NO8QI pneumatic hydraulic riveter application blind rivet nuts and bolts all materials M3 M8 which this declaration refers to is in conformity with the provisions of the regulations EC standard 98 37 EEG The Netherlands Maastricht Airport 29 08 2001 J M E L Aarts 16 User Manual XGRIP NO8QI aserfio WWW MASTERFIX COM The Netherlands Head Office Masterfix Products b v Europalaan 12 6199 AB Maastricht Airport Tel 31 43 350 84 84 Fax 31 43 350 84 88 E Mail r pisters masterfix com Germany Europalaan 12 6199 AB Maastricht Airport Tel 31 43 350 84 84 Fax 31 43 350 84 88 E Mail m smeets masterfix com Polen Masterfix Poland ul Daleka 16 60 124 Poznan Poland Tel 48 61 86 66 297 376 Fax 48 61 86 65 733 E Mail n dziedzic masterfix com United Kingdom Masterfix Products UK Ltd Units 4a b amp d Ring Road Zone 2 Burntwood Business Park Burntwood Staffordshire WS7 3JQ Great Britain Tel 44 1543 686 989 Fax 44 1543 675 822 E Mail k johal mast
3. 5 M6 M8 M4 M5 M6 M8 User Manual XGRIP NO8QI 4 SAFETY INSTRUCTIONS Anyone who operates or maintains the NO8 riveter must first read this User Manual carefully paying extra attention to the instructions below Never dismantle the tool without first having thoroughly studied the instructions given in this User Manual and applying them Always use the tool in accordance with the specified safety instructions Direct any queries regarding optimal and safe operation or use of the tool to Masterfix Products The safety instructions must be made clear to all persons involved Never connect the tool to any medium other than compressed air Hold the air hose firmly when disengaging to prevent it from hurtling to and fro due to the escaping air Use the tool only for the installation of blind rivet nuts bolts The tool must never be used for giving blows or impacting or as a hammer Do not make any modification s change s Any modifications to the tool or supplied parts and their consequences are completely outside the liability of Masterfix Products and are entirely the liability of the operator any guarantee claim shall then be null and void Masterfix Products is always prepared to advise you with regard to different applications The tool must be constantly maintained and examined inspected at regular intervals Maintenance shall be performed by staff trained for that purpose Do not perform any maintenance before r
4. AL START UP The tool must be connected to an air filter separator unit this unit filters the compressed air to separate dirt and condensate A pressure regulator with a preferred setting of 6 bar min 5 bar max 7 bar must be installed if the operating pressure of the compressed air exceeds or might exceed 7 bar Use dry and clean materials hoses couplings fittings etc to connect the tool to the filter separator unit Check whether any leakage occurs anywhere in the compressed air supply If so replace the damaged hoses or coupling Check the compressed air supply pressure to the tool this may be max 7 bar Drain the condensate from the filter separator unit Also check the dirt filter The riveter is supplied ready for use The tool need not be filled with oil prior to initial start up The NO8QI is supplied as standard with fitted M8 nose and threaded mandrel The NO8QI is standard set at its minimum pressure adjustment 6 DESCRIPTION OF THE NO8QI The following can be found at the bottom of the tool Compressed air supply hose 0 5 m length 6 mm ID with union coupling item 56 see fig 6 1 Pressure relief valve item 48 acting as safety valve to prevent overloading of the tool The valve opens if the compressed air pressure exceeds 7 bar You can see the pressure with the green indicator item 48a It is possible to fit the supply hose to the other side at the location of the pressure relief valve The pres
5. IP NO8QI 9 GUARANTEE AND SERVICE The user will not be able to claim under guarantee if he does not observe the instructions specified in this User Manual A guarantee period of 6 months applies starting from the date of purchase The liability of Masterfix Products for this riveter and or any of its defective parts shall be limited to their replacement the changing of wear and tear parts like mandrels sealings etc is excluded In no case shall the liability exceed the invoiced value of the supplied items Masterfix Products shall not be liable under any circumstances for damage or costs occurring due to inexpert use of the tool and repair or replacement of parts performed by anyone other than Masterfix Products itself To be able to make any guarantee claim the guarantee form must be completed and sent to Masterfix Products see last page of the User Manual for guarantee form Maintenance shall be performed in accordance with the instructions solely by technical persons qualified for the purpose It is advisable to consult Masterfix Products for advice on repairs or to present the tool for repair to Masterfix Products MASTERFIX PRODUCTS B V EUROPE P O Box 21 6190 AA Beek The Netherlands Europalaan 12 6199 AB Maastricht Airport Tel 31 0 43 350 84 84 Fax 31 0 43 350 84 88 14 User Manual XGRIP NO8QI GUARANTEE FORM MASTERFIX PRODUCTS BV EUROPE P O BOX 21 6190 AA Beek The Netherlands To be
6. O8QI 6 3 SETTING THE PRESSURE The pressure can be adjusted by the set screw item 52 see Fig 6 3 1 at the bottom of the tool The tool is set at its minimum pressure when it leaves the factory Turn the set screw clockwise to increase the pressure Turn the set screw anti clockwise to reduce the pressure When reducing the pressure always operate the trigger to let the pressure release The set pressure can be read from the pressure indication see Fig 6 3 1 For adjusting the pressure belonging to the nut bolt first adjust to the minimum pressure and then slowly increase place a nut bolt on the mandrel adapter operate the trigger and increase the pressure by turning the set screw item 52 clockwise until the nut bolt deforms Figure 6 3 1 If problems should occur with the setting of the pressure disconnect the tool from the compressed air supply to release the tool from the pressure TESTING THE PRESSURE Checking the pressure setting in a field test is recommended A number of blind riveting nuts or bolts are installed into the original material or a test plate for this purpose This test plate must have the same thickness and hole diameter also ensure that the test plate and the work piece are made of the same material User Manual XGRIP NO8QI 7 2 73 MAINTENANCE OF THE N0O8QI DAILY MAINTENANCE Check the mandrel adapter for damage The threads must not be damaged Check the pressure setting se
7. User Manual XGRIP NO8QI MASTERFIX PRODUCTS BV EUROPE Maastricht Airport The Netherlands User Manual XGRIP NO8QI CONTENTS OF USER MANUAL NO08QI 1 Area of application 2 Specifications and dimensions 3 Standard equipment 4 Safety instructions 5 Initial start up 6 Description of the NO8QI 6 1 Operation 6 2 Threaded mandrel adapter and nose replacement 6 3 Setting the stroke 7 Maintenance 7 1 Daily maintenance 7 2 Weekly maintenance 7 3 Overhaul 7 4 Adding oil 8 Parts list with general arrangement 9 Guarantee and service Guarantee form User Manual XGRIP NO8QI 1 AREA OF APPLICATION and sizes RIVET NUTS RIVET BOLTS aluminium steel stainless steel all materials M4 M4 M4 M4 M5 M5 M5 M5 M6 M6 M6 M6 M8 M8 M8 M8 2 SPECIFICATIONS i 2 3 kg Weight cin 313 mm Height 276 mm Stroke max 9mm max 2 7 litres Air consumption per stroke Operating pressure 5 7 Traction power at 6 bar 21000 Nose holder dia x L 25 x 75 mm Subject to technical alterations The NO8QI is conform to the EC standard 98 37 EEC Opmerking 1 User Manual XGRIP NO8QI DIMENSIONS 3 STANDARD EQUIPMENT FOR N0O8QI nose pieces mandrels for rivet nuts adapters for rivet bolts One oil refill kit comprising one bottle hydraulic oil one 3 mm Allen key one filling syringe one user manual AVAILABLE ON DEMAND Nosepiece M3 Mandrel M3 M4 M5 M6 M8 M4 M
8. e section 6 3 for setting the pressure Check if there is any leakage in the compressed air supply If yes replace the damaged hoses or couplings Check the compressed air supply pressure this may be max 7 bar Drain the condensate from the filter separator unit Also check the dirt filter WEEKLY MAINTENANCE Check the oil level There may be insufficient oil if the stroke of the tool is insufficient for correct fitting of the nut bolt Add oil in that case see section 7 4 adding oil OVERHAUL Overhaul shall be performed after every 300 000 rivet nuts bolts or once every 3 years The tool is then completely dismantled and all seals and worn parts are replaced We advise to have the overhaul performed by Masterfix Products 10 User Manual XGRIP NO8QI 7 4 ADDING OIL There may be insufficient oil if the stroke of the tool is too small for proper installation of nuts bolts First check whether the stroke setting is correct see section 6 3 for setting the stroke The oil level indicator item 46 shows whether loss of oil has occurred The tool has lost oil if the oil level indicator pin no longer protrudes Proceed as follows to add oil 1 Keep the tool upright during all operations Disconnect the tool from the air supply 2 Unscrew the M4 cap screw item 18 from the body item 21 using the size 3 mm Allen key Make sure the O ring item 19 remains in the hole 3 Fill the Supplied syringe with hydraulic
9. eading this User Manual Do not hesitate to contact Masterfix Products if you should need training Always use the tool in accordance with the specified safety instructions Direct any queries regarding optimal and safe operation or use of the tool to Masterfix Products The safety instructions must be made clear to all persons involved Always shut off the air supply before replacing the mandrel adapter or nose piece Always disconnect the tool from the air supply before carrying out repairs or maintenance Disconnect the tool in case of failure before investigating the reason Never aim the tool at any person or object other than the material to be riveted Adopt a stable position and location before operating the tool The air discharge openings at the bottom and back must never be covered or blocked Ensure that air hoses are in good condition and can withstand a minimum compressed air pressure of 10 bar Never exceed the maximum air pressure of 7 bar Always wear eye protection when using the riveter Eye protection must be worn not only by the user but also by everyone at the working place Prevent excessive contact with hydraulic oil which could produce a rash To prevent accidental operation the trigger must never be touched when the tool is being relocated Ensure that loose garments ties long hair rags etc cannot be caught by the moving parts of the tool Hearing protection is advised User Manual XGRIP NO8QI 5 INITI
10. er by turning it anti clockwise In this position screw the selected mandrel adapter until it stops by turning clockwise You have the correct mandrel adapter if its thread corresponds to that of the nut bolt Release the security part item 7 and ensure that the retaining device covers the hexagon of the mandrel adapter well Push the protective sleeve item 6 backwards and secure it Screw the relevant nose piece with the lock nut into the nose piece holder You have the correct nose piece if it fits tightly round the thread of the mandrel or bolt Adjusting the nose piece item 2 For nuts Screw a nut up to its collar against the nose piece on the mandrel and adjust the nose piece The nose piece is set properly if the thread of the mandrel protrudes 1 thread from the back of the nut screwed on the mandrel Retain the nose piece and lock it with the lock nut key SW 20 B For bolts Connect the tool to the compressed air supply Screw the nose piece against the adapter The air motor should not start running if it does unscrew the nose piece until it stops Now unscrew the nose piece by another 11 turns Disconnect the tool from the compressed air supply Retain the nose piece and lock it with the lock nut Replacement of the mandrel adapter with nose piece is now completed Then the riveter must be set at the correct pressure belonging to the nut bolt and the clamping capacity see section 6 3 setting the pressure User Manual XGRIP N
11. erfix com Spain Black amp Decker Ib rica S C A Business Unit Masterfix Ctra M 300 Km 29 700 28802 Alcal de Henares Madrid Espana Tel fono 34 91 883 57 30 Fax 34 91 880 87 20 E mail d gomez masterfix com 17
12. oil a bottle is also supplied with the tool 4 Screw the filled syringe up to the O ring in the hole Then slowly inject the oil into the tool ensure no air is injected Adequate oil has been added as soon as resistance is sensed The tool now has its optimal stroke again The excess oil will flow back when the syringe is released if more oil is added than necessary 5 Unscrew and remove the syringe from the body Check whether the O ring remains in the hole 6 Screw the M4 cap screw into the hole using the size 3 mm Allen key 7 Wipe off the excess oil 11 User Manual XGRIP NO8QI 8 PARTS LIST Item No Quantity Description 1 1 mandrel M4 1 1 mandrel M5 1 1 mandrel M6 1 mandrel M8 1 1 adaptor M4 1 1 adaptor M5 1 1 adaptor M6 1 1 adaptor M8 2 1 anvil M4 2 1 anvil M5 2 1 anvil M6 2 1 anvil M8 3 6 1 front sleeve complete T 1 security part 8 1 springholder 9 1 spring 10 1 Pin cylindrical 3 0 x 6 11 1 Lock nut 12 1 o ring 14 3 2 4 hydraulic plunger rod 13 1 o ring 20 1 front sleeve 14 1 hydraulic plunger complete 15 1 o ring 18 2 2 hydraulic plunger rod 16 1 lip seal 26 18 6 hydraulic plunger rod 17 1 buffer ring hydraulic plunger 18 1 cap screw M4 x 8 19 1 o ring 4 1 5 20 1 hanger 21 1 hydraulic body 22 1 lip seal 34 22 9 4 hydraulic piston 23 1 guide ring 34 22 2 5 Teflon 24 1 o ring 28 3 hydraulic piston 25 1 o ring 36 2 rear screwed joint
13. rial Be sure to use the correct hole size consult the catalogue for the hole sizes to be used The following rule of tnumb applies the hole size in the material is 0 1 mm larger than the outside diameter of the nut bolt The nut bolt is installed by operating the trigger The mandrel adapter automatically rotates anti clockwise and comes off the nut bolt when the trigger is released The next nut bolt can now be placed on the tool The time of anti clockwise rotation can be set by turning the adjustment screw item 72 see Fig 6 1 2 By turning the screw clockwise the time of rotation is enlarged By pushing the push button item 34 extra anti clockwise rotation is possible 6 2 THREADED MANDREL ADAPTER AND NOSE REPLACEMENT You have the correct mandrel adapter item 1 see 6 2 1 if its threads correspond to that of the nut bolt You have the correct nose piece item 2 if it fits tightly round the thread of the mandrel or bolt User Manual XGRIP NO8QI Proceed as follows to replace a mandrel adapter with nose piece 1 Disconnect the tool from the compressed air supply figure 6 2 1 Unscrew the lock nut of the nose piece item 2 from the nose piece holder item 4 key SW 20 Screw the nose piece with the lock nut right out of the nose piece holder The lock remains on the nose piece Push the protective sleeve item 6 forward Push the security part item 7 backwards In this position release the mandrel adapt
14. sure relief valve is then relocated to the supply hose connection Set screw for pressure adjustment item 52 Pressure indicator item 45 Oil level indicator item 46 Needle valve for time of return item 72 figure 6 1 User Manual XGRIP NO8QI 6 1 OPERATION Fit the correct threaded mandrel adapter item 1 see chapter 8 and nose piece item 2 to the tool see section 6 2 for threaded mandrel adapter or nose piece replacement Set the nose piece The nose piece is correctly set if the mandrel protrudes by one thread from the back of the nut see section 6 2 item 7 for setting the nose piece Connect the tool to the compressed air supply using the quick action coupling Ensure that the filter separator unit is set at an operating pressure between 5 and 7 bar Set the correct pressure The pressure can be adjusted by the set screw item 52 at the bottom of the tool see section 6 3 for setting the pressure Figure 6 1 1 Figure 6 1 2 The NO8QI is provided with a fully automatic air motor for screwing nuts bolts on and off First screw the nut bolt one turn on the mandrel adapter By pushing the nut bolt straight against the mandrel adapter see Fig 6 1 1 the mandrel adapter will start to rotate in clockwise direction to screw the nut bolt on Ensure that the collar of the nut bolt is facing towards the nose piece The rotation stops automatically when the nut bolt hits the nose piece Place the nut bolt in the mate
Download Pdf Manuals
Related Search
Related Contents
Kärcher Spray wax WBR-6005 L1 QIG R01 front.ai iPad Client User Guide Serie MIT300 Probadores de aislamiento y continuidad user manual for GRX-1155R-70±¾ Weider WEFMBE1477 User's Manual 取扱説明書 - ノイズ研究所 brochure - Hitachi Construction Machinery Europe PCL-836 Multifunction counter- timer and digital I/O add Copyright © All rights reserved.