1. Note 1 In the process of entering user IDs five digit IDs are automatically verified For IDs with less than five digits press to enter the verification process 2 The device automatically enters the process of deleting the next user when a user is deleted Delete All Users 1 The administrator password is authenticated 2 Press 9 The indicator turns green and makes a long beep 3 Press 9 The indicator turns green and makes a long beep Note Press 9 for automatic confirmation Other values are considered invalid If an invalid value is entered the device indicator turns red and the device makes 5 Exit The device automatically exits the process when the operation is completed 4 Deleting All Users is successful The indicator turns green and makes a long beep a long beep and exits the process 2 Access Control Management 2 1 Change Eight Passwords for Opening the Door 1 The administrator password is authenticated 2 Press3 The indicator turns green and makes a long beep 3 Enter the password ID of the to be changed password The password ID ranges from 1 to 8 Failed The indicator turns red and makes three beeps 6 The password is changed The device indicator turns green and the device makes a ___ 5 Enter the new password m again fo
2. Configure Alarm setting Configure Error Operation Triggered Alarm Configure Tamper Alarm 4 Configure Alarm Delay for the Door Status Sensor Operation Instructions 1 User Management 1 1 Administrator Operations To ensure data security of the device you can operate the device only after the administrator password is authenticated Authenticator the Administrator Password 1 Press The indicator is off and makes a long beep 2 Press You can authenticate the password 3 Enter the administrator password The initial password is 1234 YES 5 Exit Press or do not operate the device within 20 seconds 4 The authentication is successful The indicator turns green Note The initial administrator password is 1234 You are advised to change the initial password at the beginning Change Administrator Password 1 The administrator password is authenticated 2 Press 8 You can change the password 3 Enter a new administrator password Failed The indicator turns red and makes three beeps YES 6 Exit The device automatically exits the process when the operation is completed 5 Succeeded The indicator turns green and the makes a long beep 4 Enter the new administrator pa
3. X7 Access Control System User Manual 1 Remove the screw on the 2 Take away the back cover 3 Fix the back cover on the wall according to the mounting paper bottom of device 4 Fix the device to the back 5 Fix the screw cover 2 Structure and Function Access Control System Function 1 If a registered user verified the device will export the signal to unlock the door 2 Door sensor will detect the on off state If the door is unexpected opened or improperly closed the alarm signal digital value will be triggered 3 If the device being illegally removed the device will export alarm signal 4 External exit button is supported it is convenient to open the door inside 5 External bell is supported 3 Lock Connection A Warning No operation when power on 1 The system supports NO LOCK and NC LOCK For example the NO LOCK normally open at power on is connected with NO terminal and the NC LOCK is connected with NC terminal 2 When the Electrical Lock is connected to the Access Control System you need to parallel one FR107 diode equipped in the package to prevent the self inductance EMF affect the system do not reverse the polarities DShare power with the lock Device share power with the lock ULOCK 12V J ILOCK gt 1A T And the lock is near to the 1 device Device does not share power y with the lock T A ULOCK 12V IILOCK S1A B ULOCK 412V C The lock
4. after the door is closed 2 Press 0 3 Press 5 1 The administrator password is authenticated The indicator turns green and makes a long beep The indicator turns green and makes a long beep 6 Exit The device automatically exits the process when the operation is completed 5 The configuration is successful The indicator turns green and makes a long beep 4 Configure the door __ sensor mode 0 enable 1 disable 2 without door status sensor 11 Note The door sensor mode configured here is used as the basis for the door sensor alarm 2 6 Configure Alarm Note If an alarm is triggered the buzzer of the device generates an alarm 30 seconds later the alarm is switched to an alert The alarm can be terminated after the user is authenticated Configure Alarm setting The defaute should be on when it is set to be close then Error Operation Triggered Alarm Tamper Alarm the Alarm Delay for the Door Status Sensor will be disabled 2 Press 0 3 Press 1 1 The administrator password is authenticated The indicator turns green The indicator turns green and makes a long beep and makes a long beep 6 Exit The device automatically exits the process when the operation is completed 5 The configuration is successful The indicator turns green and makes a long b
5. Configure Alarm Delay for the Door Status Sensor DSen Delay Door Sensor Delay indicates the delay in checking the door sensor after the door is open If door sensor state is inconsistent with the normal state set by the door sensor switch an alarm will be generated and this period of time is regarded as the door sensor delay 13 1 The administrator password is authenticated 2 Press 0 The indicator turns green and makes a long beep 3 Press 4 The indicator turns green and makes a long beep 6 Exit The device automatically exits the process when the operation is completed kK 5 The configuration is successful The indicator turns green and makes a long beep __ 4 Configure the alarm 7 delay range to 254 Note Three digit values are automatically verified For values with less than three digits press to enter the verification process Values greater than 254 are considered invalid 14
6. completed and makes a long beep Note 1 Details about the authentication mode are as follows Authentication type Description Mode Mode 1 number Only password verification Mode 2 number2 Only RF Card verification Mode 3 number3 Only fingerprint verification 10 Mode 4 number4 FP PW RF fingerprint or password or RF verification Mode 5 number5 RF amp PW RF and password verification Mode 6 number6 FP amp PW fingerprint and password verification 2 4 Configure Concealed Mode If the Concealed mode is enabled the indicator is off when the Concealed mode is in the sleep mode 1 The administrator password is authenticated 2 Press 0 The indicator turns green and makes a long beep 3 Press3 The indicator turns green and makes a long beep 6 Exit The device automatically exits the process when the operation is completed 5 The configuration is successful The indicator turns green and makes a long beep 4 Configure the concealed mode 0 enable 1 disable Note An indicator blinks to indicate the status of this function when users are authenticating their cards or fingerprints 2 5 Configure Door Sensor Mode The door sensor switch includes three modes NONE The door sensor switch is not used NO The lock is open as long as the door is open NC The lock is closed
7. eep ___ 4 Configure the alarm setting 0 enable 1 disable Configure Error Operation Triggered Alarm If this function is enabled alarms are generated if a user fails the authentication upon three attempts The administrator authentication is not allowed within 20 seconds after an alarm is generated 12 1 The administrator password is authenticated 2 Press 0 The indicator turns green and makes a long beep 3 Press 2 The indicator turns green and makes a long beep 6 Exit The device automatically exits the process when the operation is completed kK 5 The configuration is successful The indicator turns green and makes a long beep 4 Configure the error __ operation triggered alarm switch 0 enable 1 disable Configure Tamper Alarm If this function is enabled alarms are generated upon device disassembly Configure whether to enable the disassembly alarm 1 The administrator password is authenticated 2 Press7 The indicator turns green and makes a long beep 3 Configure whether to enable the tamper alarm 0 enable 1 disable 5 Exit The device automatically exits the process when the operation is completed 4 The configuration is successful The indicator turns green and makes a long beep
8. ing cards in batches IDs of to be registered cards must be consecutive numbers 1 3 Authentication Users Authentication Users Fingerprints Cards Passwords After the device is powered on it enters the authentication state for users to unlock the door 1 The device is in the authentication state 2 Press fingerprints swipe cards or enter passwords Press after entering a password YES 3 The authentication is successful Failed The indicator turns red and makes three beeps Note Press after entering a password for authentication The door opens if the entered password is identical with one of the eight passwords for opening the door The initial eight passwords for opening the door are 8888 For how to change passwords for opening the door see2 1 Change Eight Passwords for Opening the Door 1 4 Delete Users Delete a user whose fingerprint or card is registered or delete all users Delete a User I Te AASE 2 Press2 3 Enter a user ID press the A eO EEI The indicator turns green F fingerprint or swipe the Pp and makes a long beep card Failed The indicator turns red and makes three beeps YES 6 Exit Press or do not operate the 5 The user is deleted m 4 Determine whether the user is authentic device within 20 seconds
9. is far apart from the 1device I P device output current ULOCK lock voltage ILOCK lock current 4 Connected with Other Parts 5 Connect with Power 7 DCI Input DC 12V 500mA 50mA standby Positive is connected with 12V negative is connected with GND do not reverse the polarities Voltage output lt DC 12V for Alarm Instructions Recommended Procedure Step 1 Install the device and power on Step 2 After the administrator password is authenticated and changed register users fingerprints cards or passwords Step 3 Configure access control parameters including modifying eight passwords for opening the door and configuring the unlocking duration authentication mode stealth mode door status sensor mode and alarm Functions of the Device 1 User Management 1 1 Administrator Operations Authenticator the Administrator Password Change Administrator Password Open the Door by the Administrator Passwor Administrator Password Be Forgotten 1 2 Add Users Add Users Register Cards in Batches 1 3 Authentication Users 1 4 Delete Users Delete a User Delete All Users 2 Access Control Management 2 1 Change Eight Passwords for Opening the Door 2 2 Configure Unlocking Duration 2 3 Configure Authentication Mode 2 4 Configure Concealed Mode 2 5 Configure Door Sensor Mode 2 6 Configure Alarm
10. on process the user ID increases automatically The device automatically enters the process of registering the next user when a user is successfully registered 2 The registration process fails if the fingerprint is of poor quality or the fingerprint or the card has been registered After the device indicator turns green Failed The indicator turns red and makes three beeps YES 5 Exit Press to exit 4 Adding Users is successful The indicator turns green and makes a long beep 6 you can register the user again Registered users must not be registered again Register Cards in Batches 1 The administrator password is authenticated 2 Press 6 Registering Cards in Batches 3 Swipe the first card once only The indicator turns red and makes three beeps Failed 6 Exit The device automatically exits the process when the operation is completed 5 Cards are successfully registered in batches YES 4 Enter the total number of cards Note 1 In the process of entering the total number of cards three digit numbers are automatically verified For numbers with less than three digits press to enter the verification process Press to reenter the total number of cards 2 You must clear all the registered users before register
11. r authentication gt 4 Enter a new password The password consists of four digits long beep 7 Exit Press or to exit Note 1 If you set a password to an all 0 password after entering the password ID this password will be locked and you cannot use this password to open the door 2 If a password is successfully changed enter the password ID of the 9 to be changed password to change the next password 2 2 Configure Unlocking Duration 2 Press 4 The indicator turns green _1 and makes a long beep 1 The administrator password is authenticated 3 Enter the unlocking duration range 0 to 255 5 Exit 4 The unlocking duration is The device automatically __ modified exits the process when the N The indicator turns green operation is completed and makes a long beep Note Three digit values are automatically verified For values with less than three digits press to enter the verification process Values greater than 254 are considered invalid 2 3 Configure Authentication Mode 1 The administrator oo o o amoa M 3 Enter the authentication password is authenticated 8 M mode and makes a long beep 5 Exit 4 The configuration is The device automatically __ successful exits the process when the N The indicator turns green operation is
12. ssword again for authentication Note Four digit passwords are automatically verified For passwords with less than four digits press to enter the verification process Open the Door by Entering the Administrator Password 1 The administrator password is authenticated 2 Press 8 The indicator turns green and makes a long beep 3 Press 0 The indicator turns green and makes a long beep Note This function can be used to open the door 5 Exit The device automatically exits the process when the operation is completed 4 The door is opened The indicator turns green and makes a long beep Administrator Password Be Forgotten If the administrator password is forgotten you can press the disassembly key three times to reset the password to the initial administrator password 30 to 60 seconds after the device is disassembled from the wall or door There is a long beep 30 seconds after the device is disassembled from the wall or door 1 2 Add Users Register the fingerprint or card of a user or register cards in batches Add Users 1 The administrator password is authenticated 2 Press1 The indicator turns green and makes a long beep 3 Register fingerprints or cards Press fingers three times to get a fingerprint or swipe the card once Note 1 In the registrati