Home
GOT2000 Series USB Environmental Protection Cover User`s Manual
Contents
1. S A Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 U S A Tel 1 847 478 2100 Brazil MELCO TEC Rep Com e Assessoria Tecnica Ltda Rua Correia Dias 184 Edificio Paraiso Trade Center 8 andar Paraiso Sao Paulo SP Brazil Tel 55 11 5908 8331 Germany Mitsubishi Electric Europe B V German Branch Gothaer Strasse 8 D 40880 Ratingen GERMANY Tel 49 2102 486 0 U K Mitsubishi Electric Europe B V UK Branch Travellers Lane Hatfield Hertfordshire AL10 8XB U K Tel 44 1707 276100 Italy Mitsubishi Electric Europe B V Italian Branch Centro Dir Colleoni Pal Perseo Ingr 2 Via Paracelso 12 l 20041 Agrate Brianza Milano Italy Tel 39 039 60531 Spain Mitsubishi Electric Europe B V Spanish Branch Carretera de Rubi 76 80 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France Tel 33 1 5568 5568 South Africa Circuit Breaker Industries Ltd Private Bag 2016 ZA 1600 Isando South Africa Tel 27 11 928 2000 Hong Kong Mitsubishi Electric Automation Hong Kong Ltd 10th Floor Manulife Tower 169 Electric Road North Point Hong Kong Tel 852 2887 8870 China Mitsubishi Electric Automation China Ltd 4 F Zhi Fu Plazz No 80 Xin Chang Road Shanghai 200003 China Tel 86 21 6120 0808 Taiwan Setsuyo Enterprise Co Ltd 6F No 105 Wu Kung 3rd Rd Wu Ku H
2. T using fixing screws and tighten the screws in the specified torque of 0 36 Nem to 0 48 Nem Loose tightening may cause the USB environmental protection cover to drop off and or the GOT to fail or malfunction Overtightening may damage and drop screws and or the USB environmental protection cover For closing the USB environmental protection cover fix the cover by pushing the PUSH mark on the latch firmly to comply with the protective structure DISPOSAL PRECAUTIONS CAUTION Dispose of this product as industrial waste TRANSPORTATION PRECAUTIONS CAUTION When fumigants that contain halogen materials such as fluorine chlorine bromine and iodine are used for disinfecting and protecting wooden packaging from insects they cause malfunction when entering our products Please take necessary precautions to ensure that remaining materials from fumigant do not enter our products or treat packaging with methods other than fumigation heat method Additionally disinfect and protect wood from insects before packing products Manuals The following shows manuals relevant to this product Detailed Manual Manual name GOT2000 Series User s Manual Hardware SH 081194ENG Sold separately 1D7MJ5 Manual number Model code For detailed manuals refer to the PDF manuals stored in the DVD ROM or CD ROM for the drawing software used Relevant Manuals For relevant manuals ref
3. cover 5 PRECAUTIONS FOR USE 1 When the USB environmental protection cover is closed the USB interface complies with the protective structure IP67F In this case the USB environmental protection cover must be fixed by pushing the PUSH mark on the latch 2 The USB environmental protection cover is a consumable product Check the cover periodically When the cover has damage heavy soil and others replace the cover Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties A For safe use e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel U
4. e is used or the USB environmental protection cover is not correctly fixed Fixing the USB environmental protection cover by pushing the PUSH mark on the latch firmly complies with IP67F 3 EXTERNAL DIMENSIONS Description Hinge for opening or closing the USB environmental Hinge protection cover Hinge projection Hinge projection to be fitted in the GOT guiding hole Packing Packing for protecting the USB interface Latch for fixing or opening the USB environmental Latch protection cover Unit mm inch 4 INSTALLATION AND REMOVAL PRO CEDURE 4 1 Install the USB environmental protection cover 1 Get up the hinge of the USB environmental protection cover 2 Put the provided fixing screw through the hinge hole Fit the hinge projections of the USB environmental protection cover in the GOT guiding holes and fit the fixing screw of the USB environmental protection cover in the USB environmental protection cover installation hole on the GOT 3 Tighten the screw with a torque of 0 36 Nem to 0 48Nem 4 When the USB interface is not used fix the cover by pushing the PUSH mark on the latch firmly 5 When the USB interface is used push the PUSH mark on the latch to open the cover and then connect the USB cable 4 2 Removing the USB environmental protection cover Perform the reverse procedure of installation for removing the USB environmental protection
5. er to the Help or the PDF manuals stored in the DVD ROM or CD ROM for the drawing software used The latest manuals are also available from MITSUBISHI ELECTRIC FA Global Website http Avww MitsubishiElectric co jp fa 2013 MITSUBISHI ELECTRIC CORPORATION Packing List After unpacking the box check that the following products are included Quanti GOT2000 Series USB environmental protection 1 GT25 UCOV cover Fixing screw M3 x 6 1 1 OVERVIEW This User s Manual describes GOT2000 series USB environmental protection cover of hereinafter referred to as the USB environmental protection cover The USB environmental protection cover is for protection of the USB interface The following table shows the USB environmental protection cover models and applicable GOTs Screen sizes for the applicable GOTs GT25 UCOV GOT in front of which has the USB interface The USB environmental protection cover is used to make the USB interface complaint with the protective structure IP67F 2 SPECIFICATIONS The following shows the performance specifications of the USB environmental pro tection cover The general specifications of the USB environmental protection cover are the same as those of the GOT For the general specifications of the GOT refer to the GOT2000 Series User s Manual Hardware Protective structure 1 IP67F Weight 0 005kg 1 The USB interface does not comply with IP67F when the USB interfac
6. fa MEE GOT2000 Series USB Environmental Protection Cover User s Manual GT25 UCOV Thank you for purchasing the GOT2000 Series Prior to use please read both this manual and detailed manual thoroughly to fully understand the product MODEL GT25 UCOV U JE MODEL CODE GOTE OOO IB NA 0800501 A 1309 MEE 1D7MI2 ISAFETY PRECAUTIONS Always read these precautions before using this equipment Before using this product please read this manual and the relevant manuals intro duced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this product In this manual the safety precautions are ranked as WARNING and CAUTION Indicates that incorrect handling may cause hazardous l A WARNING conditions resulting in death or severe injury l Indicates that incorrect handling may cause hazardous l CAUTION conditions resulting in medium or slight personal injury 4 or physical damage Note that the A CAUTION level may lead to a serious accident according to the circumstances Always follow the precautions of both levels because they are important to per sonal safety Please save this manual to make it accessible when required and always forward it to the end user INSTALLATION PRECAUTIONS CAUTION Make sure to securely fix the USB environmental protection cover onto the GO
7. siang Taipei Hsine Taiwan Tel 886 2 2299 2499 Korea Mitsubishi Electric Automation Korea Co Ltd 1480 6 Gayang dong Gangseo ku Seoul 157 200 Korea Tel 82 2 3660 9552 Singapore Mitsubishi Electric Asia Pte Ltd 307 Alexandra Road 05 01 02 Mitsubishi Electric Building Singapore 159943 Tel 65 6470 2460 Thailand Mitsubishi Electric Automation Thailand Co Ltd Bang Chan Industrial Estate No 111 Moo 4 Serithai Rd T Kannayao A Kannayao Bangkok 10230 Thailand Tel 66 2 517 1326 Indonesia P T Autoteknindo Sumber Makmur Muara Karang Selatan Block A Utara No 1 Kav No 11 Kawasan Industri Pergudangan Jakarta Utara 14440 P O Box 5045 Jakarta 11050 Indonesia Tel 62 21 6630833 India Messung Systems Pvt Ltd Electronic Sadan NO III Unit No15 M I1 D C Bhosari Pune 411026 India Tel 91 20 2712 3130 Australia Mitsubishi Electric Australia Pty Ltd 348 Victoria Road Rydalmere N S W 2116 Australia Tel 61 2 9684 7777 MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN When exported from Japan this manual does not require application to the Ministry of Economy Trade and Industry for service transaction permission Specifications subject to change without notice Printed in Japan September 2013
Download Pdf Manuals
Related Search
Related Contents
ALERTA AL CONSUMIDOR Aduro 9-7 - Stufe a legna Aduro お客様用 ・取 扱 説 明 書一 Nikon 1540B Digital Camera User Manual Graco PD191935A User's Manual Panasonic PT-LB50NTU User's Manual ARDEX IFS 取扱説明書 - 三菱電機 D。ME LーGHT用コン卜囗一ラ一 DLC 一 303D 取扱説明書 Télécharger le livre blanc sur les communications unifiées Copyright © All rights reserved.