1.            This unit is equipped with 3 weight unit modes  i e  kg  lb and  lb oz   Default weight unit   kg  without pound units        Follow the below step to employ  disable  the pound weight unit     a  turn scale off    0 Qa a oso    4 8  4 8 1    press and hold TARE  then press ON OFF  Scale displays    F 1     press TARE twice  Scale displays  F 3     press and hold MODE       press MODE unit the    lb    signs appear  or select    kg    to disable       the pound unit   press ZERO to confirm and return to normal operation status    If the pound weight is selected  Press MODE to shift among  lb    and lb oz during operation              TO TARE OFF THE WEIGHT OF A CONTAINER   Place a container onto the platform    then press TARE to tare off the weight of this container  After  TARE is pressed  the tare sign appears    To Clear Container Weight from Memory    To clear the weight of the container  remove the container and       all loads from the platform and press TARE  then tare sign would    disappear     Zero the Weight Displayed When Unloaded       If zero sign does not appear when unloaded  press ZERO to reset    weight to zero     PLACING A LOAD  Always place a load onto the platform gently  Sudden       shock excessive force may cause damage to the weight sensor inside           It is a goodpractice to remove all loads fromplatformimmediately       after weighed  This would prolong the life time of the weight    sensor     SELECT BACKLIGHT  option  STATUS      
2.        Toenable disablebacklight function  press MODE until the desired          status is attained  Backlight would automatically go off 3 second       after zero weight is detected and automatically turned on       immediately after a load is detected     WEIGHT MEMORY FUNCTION    Save a Weight to Memory and Auto Weight Accumulation       When weight display is stable  press M  to save  Scale Displays       P 1    and the M  arrow appears indicating total number of total       entries and the memory function is being employed     4 8 2    ao a   pp    Recall Weight Accumulated   Press MR  scale displays total number of entries and total   accumulated weight of these translations  Scale return to normal   operation status 2 seconds after accumulated weight displayed    Memory Clear   Press andholdMR  then press TARE afteraccumulatedweight display   Scale displays    P 0    and all data is cleared     CAUTIONS  ALL data stored will be erased if   the scale is turned off    weight unit is changed    SELECT AUTO POWER OFF STATUS  This unit is equipped with AUTO POWER OFF function                 Default setting   auto off after 4 minutes unused   Follow the below steps to disable employ the AUTO POWER OFF             function   turn scale off    press and hold TARE  then press ON OFF  Scale displays    F 1          press TARE for three times  Scale displays    F 4     press MODE to select        to disable the auto power off function select    O oFF          F     to employ the
3.  auto power off unction select    4 oFF             press ZERO to confirm and return to normal operation status     5 TROUBLE SHOOTING    SYNDROME SCALE CANNOT BE TURNED ON    CHECK  ACTION    CHECK    CHECK    ACTION          Is the rechargeable battery charged    Recharge the battery for at least 8 hours or plug in the mains  adapter input    Is the main adapter AC input inserted properly both to the  wall outlet           Is the output plug of the main adapter inserted properly into  the DC inlet of the scale     Secure both ends of the main adapter to the wall outlet and          DC inlet of scale        SYNDROME    SCALE TURNED ON BUT ZERO WEIGHT CAN    NOT BE ATTAINED    CHECK  ACTION  CHECK    ACTION    SYNDROME    CHECK  ACTION    Is anything load applied to platform     Remove all loads from platform           Is the scale affect by air flow  vibration or RF        Place scale away from all disturbances        RATED CAPACITY CANNOT BE ATTAINED  Is the TARE          sign go on     Turn scale off  remove all loads from platform and       turn of again     CHECK  ACTION    SYNDROME  CHECK  ACTION  CHECK  ACTION  CHECK  ACTION  CHECK  ACTION  CHECK  ACTION    SYNDROME  CHECK  ACTION  CHECK  ACTION    SYNDROME SCALE DISPLAYS    CHECK  ACTION    Anything obstructing the platform     Remove all obstacles     SCALE DOES NOT WEIGH CORRECTLY  Is the  Select    right weight unit employed   the right weight unit    scal  the    Is the  Adjust       e placed horizontally     adju
4.  provided     1 3  1 3 1       Power on the Scale    Check the input voltage of the main adapter scale matches with       the voltage of electricity outlet  Contact your local dealer if    not           Before first time operation  plug the main adapter mains plug    to the wall outlet and charge the scale for at least 8 hours     Retain the package for future transportation of scale     2  SPECIFICATIONS       GENERAL SPECIFICATIONS                            apacity  IM 300  660 1b   rm 600  1320 1b 0 2 1b          Hastorn sizs  ji x 23 6       Power source Built in rechargeable  battery or power adaptor  Max  Tare range Up to 100  of rated  capacity   Max  Zero range Up to 2  rated capacity  etric  decimal pound   Note A and pound ounce  Operation 0   40  C  32   104  F    Environment             Non condensed  R H   85        Specifications subject to change without notice     NOTE A     To comply with the law of certain countries  the avoirdupois weight          units may be disabled  Contact your dealer for more information        3  KEYBOARD LAYOUT AND DESCRIPTION       UWE 2       ON OFF KEY    Press this key to turn scale on or off     2  MODE KEY    Press this key to switch between metric and avoirdupois weight units       with or without backlight  optional      M  KEY    Press this key to enter present weight value into memory        4  MR KEY    Press this key to recall the accumulated weight value in memory     5  TARE KEY    Press this key to tare off the weigh
5. intelligent     Weighing Technology    LM SERIES    BENCH FLOOR SCALE    OPERATION MANUAL          PLEASE READ THIS INSTRUCTION MANUAL VERY CAREFULLY BEFORE ATTEMPTING  TO OPERATE THIS SCALE                                                 AUGUST 2003 REV 1    Specifications subject to change without prior notice    CONTENTS       1 NSTALLAT          ON             2 SPECIFICATIONS                               3 KEYBOARD LAYOUT AND DESCRIPTION                               4 INSTRUCTIONS FOR USE          5 TROUBL                   6 DAILY CARE AND MAINTENANCE          E SHOOTING                              NSTALLAT          ON DIAGRAMS             1 2 3    N    1 2 4    INSTALLATION    CHECK and make sure that the following accessories are included       inside the package        This Operation Manual  Indicator x 1  Platform   stainless steel       cover x 1     Mains adapter x 1  Pillar x 1 and Screws  amp  tool set x 1           Contact your dealer if any items are missing   FIXING THE PILLAR       Thread the cable from platform through the pillar very carefully                    Insert the pillar to the pillar support attached to the platform  in a upright position  then locked it by the Allen head screw  provided     Connect the cable plug to the indicator receiving plug         3 1After plugs are connected  lock the    plugs by turning the plug screw in clockwise direction   FIXING THE INDICATOR       FOR FM  amp  LMMODELS  Lock the indicator to the pillar by 2 screws
6. stable feet to obtain level condition        fe    Is the scale a vibration or RF        ect by air flow     Fa    Place rom all disturbances        scale away                Is the scale calibrated correctly        dealer        Contact your local          Is part of the load striking against the pillar   Place load properly     SCALE TURNED OFF AUTOMATICALLY  Is the Auto Off Function employed   Reset the Auto Off Function           Is the LO BAT sign is on                 Recharge the battery or plug in the mains adapter input     w 00000 wv       xcesses th       Is the weight of load max  capacity     Removed loads on platter and check again     6  DAILY CARE AND MAINTENANCE    6 1 Clean the platform and indicator with a soft and damp cloth  if       necessary with a mild detergent        6 2 Donot useany harsh  abrasivematerial  acetone  volatile solvent     thinner or alcohol for cleaning        6 3 Verify the accuracy of the scale periodically  Re calibrate the       scale when needed        NOTE  in some countries calibration is restricted to be done by       qualified authorized agent only  Contact your local dealer for more          information    6 4 Clean the scale before long term  storage    6 5 Store the scale in a dry and cool place     7  INSTALLATION DIAGRAM BM or FM  amp  LM     gt        Th  7 4  a              Db   f      TT ay E    arai N j LLI     by  a IP  gt     A  BM TYPE B  FM TYPE    
7. t of a container and get the net       weighing result     6  ZERO KEY    Press this key to reset weight displayed to zero when unloaded     7  MC KEY  Press the MR and TARE key simultaneously to clear all data in memory     8  ZERO INDICATOR  An arrow will appear and point at this sign to indicate a zero weight    status     9  TARE INDICATOR    An arrow will appear and point at this sign when the tare function is       being employed     10  M  INDICATOR  An arrow will appear and point at this sign when the memory contains    data   11  WEIGHT UNIT INDICATOR     kg  indicates the metric unit is being employed         Ib  indicates the avoirdupois unit is being employed        12  LO BAT INDICATOR    When this indicator appears  recharge the scale immediately  Failure          to do so may cause unrecoverable damages to the rechargeable battery       inside     13  IN CHARGE INDICATOR  Red color  Recharging battery    Green color  Charging completed    4  INSTRUCTIONS FOR USE    4 1 PLACING SCALE    Use this unit on a hard and strong surface  where is free from       RF interference  vibration  fire  direct sunlight and excessive       moisture  For accurate weighing  always place this unit ona level       surface  if necessary  adjust the adjustable feet underneath the    platform to obtain a level condition     4 2 POWER THE SCALE  Press ON OFF to turn scale on     4 3 INTERNAL SETTINGS  Before weighing  make sure the zero sign is on and stable   4 3 1 Select Weight Unit  
    