Home
        FLEXIPAR - MBT Lighting
         Contents
1.   Insert the lamp in the lampholder    Step 4  Insert the lampholder and close the device   Do not operate this device with opened housing     Overhead rigging  The installation of the projector has to be built and constructed in a way that it can hold 10 times the  weight for 1 hour without any harming deformation     The installation must always be secured with a secondary safety attachment  e g  an appropriate catch net   This secondary safety attachment must be constructed in a way that no part of the installation can fall  down if the main attachment fails     When rigging  derigging or servicing the fixture staying in the area below the installation place  on bridges   under high working places and other endangered areas is forbidden     The operator has to make sure that safety relating and machine technical installations are approved by an  expert before taking into operation for the first time and after changes before taking into operation another  time     The operator has to make sure that safety relating and machine technical installations are approved by an    1 2    USER MANUAL FLEXIPAR    expert after every four year in the course of an acceptance test     The operator has to make sure that safety relating and machine technical installations are approved by a  skilled person once a year     Procedure    IMPORTANT  OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE  including  but not limited  to  calculating working load limits  installation material being used  an
2.  the lamps     Should you need any spare parts  please use genuine parts    If the power supply cable of this device becomes damaged  it has to be replaced by authorized dealers  only in order to avoid hazards    Should you have further questions  please contact your dealer     2 2    
3. USER MANUAL FLEXIPAR    USER MANUAL    FLEXIPA    TECHNICAL SPECIFICATIONS   Power supply  120V AC  60HZ    Power consumption  600W   Dimensions  255 x 280 x 290 mm   Net weight  4KGS   Fitting lamp  HPL575  HX600 601  GLA575   Maximum ambient temperature  45  C   Maximum housing temperature  160  C   Minimum distance  3m   Min distance form lighted object  0 5m  Professional theatre spot  With 4 exchangeable lenses  VNSP  NSP  MFL and WEL     Light output of a conventional PAR  with less power consumption  600 W     High quality die cast housing for highest stability   With  colour filter frame   Optional barndoors    Ideal for theatres  large stages and mobile use    INSTALLATION  Installing Replacing the lamp  DANGER TO LIFE  Only install the lamp with the device switched off  Unplug from mains before   CAUTION  The lamp has to be replaced when it is damaged or deformed due to the heat   Before replacing the lamp  unplug mains lead and let the lamp cool down  approx  5 minutes    During the installation do not touch the glass bulbs bare handed  Please follow the lamp manufacturer s  notes   Do not install lamps with a higher wattage  Lamps with a higher wattage generate temperatures the device  was not designed for  Damages caused by non observance are not subject to warranty   For the installation  you need one lamp   Procedure    Step 1  Open the lampholder cover by loosening the fixation screw    Step 2  If replacing the lamp  remove the old lamp from the spot    Step 3
4. d periodic safety inspection of  allinstallation material and the projector  If you lack these qualifications  do not attempt the installation  yourself  but instead use a professional structural rigger  Improper installation can result in bodily injury  and or damage to property    The projector has to be installed out of the reach of people    If the projector shall be lowered from the ceiling or high joists  professional trussing systems have to be  used  The projector must never be fixed swinging freely in the room    Before rigging make sure that the installation area can hold a minimum point load of 10 times the  projector s weight    Mount the projector with the mounting bracket to your trussing system using an appropriate clamp  The  hole in the mounting bracket has a diameter of 10 mm    For overhead use  always install a safety rope that can hold at least 12 times the weight of the fixture  You  must only use safety ropes with quick link with screw cap  Pull the safety rope through the hole on the  back of the device and over the trussing system or a safe fixation spot  Insert the end in the carabine and  tighten the safety screw    The maximum drop distance must never exceed 20 cm    A safety rope which already hold the strain of a crash or which is defective must not be used again    Adjust the desired inclination angle via the mounting bracket and tighten the fixation screws     CLEANING AND MAINTENANCE   The operator has to make sure that safety relating and mac
5. hine technical installations are inspected by an  expert after every four years in the course of an acceptance test    The operator has to make sure that safety relating and machine technical installations are inspected by a  skilled person once a year    The following points have to be considered during the inspection    1  All screws used for installing the devices or parts of the device have to be tighly connected and must  not be corroded    2  There must not be any deformations on housings  fixations and installation spots  ceiling   suspension  trussing     3  The electric power supply cables must not show any damages  material fatigue  e g  porous cables  or  sediments  Further instructions depending on the installation spot and usage have to be adhered by a  skilled installer and any safety problems have to be removed     DANGER TO LIFE    Disconnect from mains before starting maintenance operation    We recommend a frequent cleaning of the device  Please use a moist  lint free cloth  Never use alcohol or  solvents    The objective lens will require weekly cleaning as smoke fluid tends to building up residues  reducing the  light output very quickly    The interior of the device should be cleaned at least annually using a vacuum cleaner or an air jet    There are no serviceable parts inside the device except for the lamp  Maintenance and service operations  are only to be carried out by authorized dealers    Please refer to the instructions under  Installing Replacing
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
SERVICE MANUAL  6229 - Candide  Manuel d`Instructions    Manual de instrucciones  Rockford Fosgate T10001 BD User's Manual  Manual de instruções - Transmissor de pressão diferencial    Copyright © All rights reserved. 
   Failed to retrieve file