Home
8" QuickPanel View Intermediate Color TFT User`s Manual, GFK-2512
Contents
1. A 4 Environmental A 5 Battery A 5 Calendar Clock A 5 Agency Approvals A 6 Diagnostics B 1 Power up B 1 Pocket Internet Explorer B 1 Physical Unit B 2 GFK 2512 1 1 Welcome Congratulations on your purchase of a QuickPanel View the most advanced compact HMI available The QuickPanel View is available in different configurations to suit your requirements Equally adept in a networked environment or as a stand alone unit the QuickPanel View is the ideal solution for factory floor HMI Powered by Microsoft Windows CE today s embedded operating system of choice the QuickPanel View provides a fast track for application program development The comm
2. GE Fanuc Intelligent Platforms Operator Interface Products 0H8 QuickPanel View 1HIntermediate Color TFT IC754VBI08CTD IC754VGI08CTD 2HHardware User s Guide 3HGFK 2512 4HSeptember 2008 GFL 002 Notices Warnings Cautions and Notes as Used in this Publication Warning Warning notices are used in this publication to emphasize that hazardous voltages currents temperatures or other conditions that could cause personal injury exist in this equipment or may be associated with its use In situations where inattention could cause either personal injury or damage to equipment a Warning notice is used Caution Caution notices are used where equipment might be damaged if care is not taken Note Notes merely call attention to information that is especially significant to understanding and operating the equipment This document is based on information available at the time of its publication While efforts have been made to be accurate the information contained herein does not purport to cover all details or variations in hardware or software nor to provide for every possible contingency in connection with installation operation or maintenance Features may be described herein which are not present in all hardware and software systems GE Fanuc assumes no obligation of notice to holders of this document with respect to changes subsequently made GE Fanuc makes no representation or warranty expres
3. September 2008 GFK 2512 4 DRAM Memory The QuickPanel View is equipped with 32 MB of dynamic RAM Part of the DRAM 15 8 MB is reserved for the Windows CE operating system and is not accessible by user applications The other 16 2 MB is split between two functions an object store for temporary file storage and the main memory for running programs Typically compressed programs stored in FLASH are expanded and moved to DRAM for execution Temporary storage of program variables or data files is also provided by DRAM any data stored in DRAM will not be retained through a power cycle or reboot The split between program memory and storage memory may be adjusted as necessary to make more room for one or the other depending on your specific application needs For example if you find that an application is short of memory use the System Properties dialog box to alter DRAM memory allocation Caution Setting Program Memory too low may prevent additional applications from starting or may cause currently running applications to fail due to lack of memory Setting Storage Memory too low may prevent the saving of files into the object store portion of the file system which may also cause application failures GFK 2512 Chapter 4 Detailed Operation 4 33 4 To change the DRAM memory allocation 1 In the Control Panel double tap System The System Properties dialog box appears 2 On the Memory tab drag the slid
4. 2 1 QuickPanel View Hardware 2 2 QuickPanel View Software 2 6 Installation for Compliance and Conformance 3 1 Connecting a DC Power Supply 3 2 Panel Cutout 3 3 Mounting Bracket Locations 3 4 Mounting the QuickPanel View in a Panel 3 5 Detailed Operation 4 1 Touch Screen Display 4 2 Communication Ports 4 10 CF Port 4 18 Ethernet 4 19 Expansion Bus 4 25 DIP Switches 4 27
5. The agency approvals listed above and on the Declaration of Conformities are believed to be accurate however a product s agency approvals should be verified by the marking on the unit itself GFK 2512 B 1 Diagnostics The tables contained in this appendix can be used to identify and remedy problems that can occur with the 8 QuickPanel View products Power up Problem Suggested remedy Blank screen No power Check all power connections to the QuickPanel CE Backlight failed This is further indicated when the left LED glows red The LED will turn red if either backlight fails Backlight timer expired Touch the screen to reactivate Pocket Internet Explorer Problem Suggested remedy Cannot access any URL when using a dial up connection to an ISP If you have previously set up an IP address on a local Ethernet Network it must be cleared Disconnect your Ethernet cable and reboot Your ISP will reassign an IP address when you reconnect the cable Appendix B B 2 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 B Physical Unit Problem Suggested remedy Slow or sluggish touch response Ensure that configured I O or communications channels such as serial or Ethernet are operating without error These errors can cause higher system overhead leading to delayed response to touch inputs Ensure that flash drives internal or external are operating without error If
6. Timeout after With this setting selected a second setting control appears allowing for entry of a timeout interval in seconds for the update utility to wait for a user response to its dialogs before automatically continuing to boot without an update occurring The user has the amount of time specified to either cancel the update or continue with the update as normal Setting the time to 0 seconds will make this option operate the same as the Skip at Startup setting 4 Select OK to keep your setting choice 5 To save the settings run Backup see page 2 9H11 2 Overview 2 19 2 Emulate PPC Emulate PPC is a utility that allows the QuickPanel to emulate a Pocket PC 2003 during an ActiveSync session enabling the download of third party Pocket PC 2003 software To use Emulate PPC during an ActiveSync session 1 Start Windows Explorer double tap Windows then double tap EmulPPC The Emulate PPC dialog box appears 2 Start the ActiveSync session When installation of third party software is complete close the dialog box to deactivate Emulate PPC HTTP File Transfer Utility The HTTP File Transfer Utility HFTU is a small standalone command line program that allows you to send and delete files to and from computers over a network The HFTU uses the HTTP protocol so you can even send files to computers over the Internet Run the HTTP utility from a command line prompt from a batch file BAT or as
7. For compliance to NEMA 4 and 4x qualification the unit must be mounted in a comparably NEMA rated IP66 equivalent panel or enclosure For compliance to ATEX Directive and Class I Zone 2 hazardous locations the unit must be mounted in an IP66 enclosure For adequate ventilation allow at least 3 inches of space between adjacent equipment and all sides of the QuickPanel Ensure that specified conditions of temperature and humidity are not exceeded In outdoor applications direct sun exposure may impose increased thermal loads on the QuickPanel leading to excessive temperature increases Cabinet design and orientation must be carefully considered to avoid exceeding the operational temperature limits These considerations could include shading for the QuickPanel and its cabinet with awnings or other solar opaque materials avoiding a due East or West facing of the cabinet providing ventilation or active cooling of the cabinet or other methods Chapter 3 3 2 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 3 Connecting a DC Power Supply 1 Using the three screw terminals shown in the following diagram attach a 24VDC 24W power supply to the plug supplied with the QuickPanel View see Appendix A Design Specifications for power supply and conductor size requirements 2 Insert the plug into the power supply socket and securely tighten the attaching screws Note The torque range for the attaching
8. GFK 2512 1 Getting Started Basic Setup Your QuickPanel View is shipped ready for use after a few configuration steps To power up all you need to do is connect a DC power supply via the supplied quick connect plug Depending on your application you may also want to connect and configure optional input devices communications ports and expansion adapters see chapter 3 Caution Electrical Shock Hazard To avoid personal injury or damage to equipment ensure that the DC supply is disconnected from power and that the leads are not energized before attaching them to the unit s power supply plug Runtime Setup To download a Proficy Machine Edition application to a QuickPanel View unit you must set up a data link between it and your development workstation For more information see Ethernet in chapter 3 and Downloading a Machine Edition Project in the Machine Edition online help GFK 2512 Chapter 1 Welcome 1 3 1 Startup When you first start up the QuickPanel View a few configuration steps are necessary To start the QuickPanel View 1 Apply DC power to the QuickPanel View Once power is applied the QuickPanel View begins initializing The first thing to appear on the display is the splash screen 2 To skip running any programs included in the StartUp folder tap Don t run StartUp programs The splash screen disappears automatically after about 5 seconds The Windows CE desktop then becomes visi
9. QuickPanel View is based on the Marvell XScale PXA255 microprocessor and employs large scale integration to provide high performance with a small footprint The following block diagram illustrates the major functional areas of the QuickPanel View and the interfaces between them 32 MB DRAM DRAM Expansion 100 pin DIMM 64 MB max 32 MB Flash 512 KB EPROM Boot 512 KB BBSRAM Buffer Field Bus Expansion Proprietary Expansion XScale PXA255 Touch Screen Backlit LCD Display Touch Screen Controller RS232 RS485 Ethernet Controller CF Card Controller 4 pos DIP Switch Real time Clock Status LEDs 2 Batt Batt Monitor COM1 25 pin Ethernet Port RJ45 CF Card Slot 100Mhz Bus Data Address Bus I2C Bus Graphics Accelerator Backlight Monitor 2 6 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 2 QuickPanel View Software Windows CE Microsoft Windows CE is the operating system for the QuickPanel View It is a full 32 bit O S with a graphical user interface This operating system is finding widespread application in hand held PCs and embedded controllers such as the QuickPanel View The familiar look and feel of Windows CE shortens the learning curve for users having experience with Windows 95 98 NT 2000 ME XP From a software developer s perspective the CE environment is a subset of the WIN32 application programming interface
10. rated half life 50 000 hours Note Backlight is not field replaceable Luminance 400 NITS Front Panel Bezel Material Valox 3706 For material specifications visit www gepolymerland com Membrane Material Touch screen top layer PET polyester with an acrylic hard coat LEDs Left Power status indicator green with power applied red if either backlight fails Right Programmable tri color green red amber Touch Screen Type Resistive 12 bit X axis 800 cells Resolution after calibration Y axis 600 cells CPU Processor XScale PXA255 Clock speed 300 MHz GFK 2512 Appendix A Specifications A 3 A Memory Flash 32 MB SRAM 512 KB Power off retention is the life of the battery DRAM 32 MB ROM 512 KB Boot loader Memory Expansion Slot Form Factor 100 pin DIMM Memory Type SDRAM Maximum DRAM 64 MB Maximum Devices Module 4 Bus Width 32 bits Bus Speed 100 MHz or faster Voltage 3 3 VDC CAS Latency CL 3 Refresh Type Self Refresh Cycle Time 64 ms maximum Error Correction Non ECC Error Detection No parity Buffering None Device Row Addressing 12 Address Lines A0 to A11 Expansion Memory Catalog Number 64 MB IC754ACC64MEM 32 MB IC754ACC32MEM Expansion Ports Compact Flash Memory One slot Type I II supports 3 3V Optional CF Card Catalog Number 512 MB IC754ACC0512MEM FieldBus One slot A 4 8 QuickPanel
11. simplifying the porting of existing software from other versions of Windows The QuickPanel View operating system is stored in a 16 MB block of FLASH memory and copied to a block of DRAM for execution The operating system starts automatically following a power up or reset of the QuickPanel View For more on Windows CE visit 0Hwww microsoft com windows embedded windowsce default mspx 2 Overview 2 7 2 Working with Windows CE Although the main user input device when working with Windows CE is the touch screen it can often be convenient to use keyboard shortcuts such as those described in the following table Keyboard Shortcut Action CTRL ESC or Opens the Windows CE Start menu Use arrow keys to select a program and ENTER to run it ALT TAB Starts the Task Manager Use it to quit unresponsive programs CTRL ALT Starts the touch screen calibration SPACEBAR Equivalent to single tap ENTER Equivalent to double tap In a dialog box equivalent to OK TAB In a dialog box select next control SHIFT TAB In a dialog box select previous control ESC Close dialog box discarding changes ARROW KEYS In a dialog box select controls or items from a list box To place a program in the Start menu 1 Start Windows Explorer 2 Navigate to the program you want to place in the Start menu 3 Tap the program s icon to select it 4 From the Edit menu choose Copy 5 Navigate to the Window
12. Management Console or other third party management consoles A Backup should be performed after configuring the FTP server and or creating the self signed certificate 2 Overview 2 25 2 To install a certificate on an FTP Client 1 Double click the certificate Select the General tab The Certificate properties are displayed 2 Click the Install Certificate button The Certificate Import Wizard appears 3 Click Next to continue The Certificate Store screen appears 4 Specify whether Windows should place the certificate in a certificate store or select another location Click Next to continue The Completing the Certificate Import Wizard screen appears 5 Click Finish to complete the installation of the certificate The Security Warning message appears This message informs you Windows will automatically trust any certificate issued by this Certification Authority 6 Click Yes to allow Windows to trust any certificate issued by this Certification Authority GFK 2512 3 1 Installation for Compliance and Conformance This chapter provides the following procedures for installing the QuickPanel View unit Connecting a DC Power Supply 3 0H2 Panel Cutout 3 1H3 Mounting Bracket Locations 3 2H4 Mounting the QuickPanel View in a Panel 3 3H5 Considerations for Choosing a Mounting Location For compliance to UL50 Type 4x rating the unit must be mounted to a flat surface of a Type 4X enclosure
13. Tap OK 7 To save the settings run the Backup utility See page 2 11 Using Windows CE Explorer you can now access anything on your local network for which you have permission 4 24 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 4 To access a remote resource on a Windows network 1 Start Windows Explorer The Explorer window appears 2 Type in the Address box or choose from a list the path to a remote resource For example MyRemoteComputer MyFolder specifies the folder named MyFolder on a computer with the name MyRemoteComputer 3 Press ENTER The resource specified is displayed as a collection of files and folders It can take a few moments to retrieve the data from your local network Note You can use the NET command from the shell to map a network resource to the QuickPanel View for frequent access The resource then appears in the Network folder GFK 2512 Chapter 4 Detailed Operation 4 25 4 Expansion Bus An expansion bus is included with the QuickPanel View and optional modules that mount directly to it are available For more information on expansion modules contact your distributor The expansion bus connectors are accessed by opening the back of the unit Caution Disconnect power from your DC power supply before opening the QuickPanel View Working on a live unit may result in damage to equipment and injury to personn
14. and retained through a power cycle if battery backup is available Daylight saving time is enabled by a check box within the dialog box The time can be displayed in the system tray on the task bar To set the real time clock 1 In the Control Panel double tap Date Time The Date Time Properties dialog box appears Note Tap Apply after making changes in any box 2 To modify the date select the Date Time tab 3 Tap the year to choose a new year tap the month to choose a new month 4 Tap a date to specify the day of month 5 From the Time Zone box choose your zone 4 40 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 4 6 Select Auto Adjust DST to configure the clock to automatically compensate for daylight savings time 7 In the Current Time box adjust the hours minutes and seconds 8 Tap OK to finish 9 To save the settings run the Backup utility See page 2 11 To display the time on the taskbar 1 From the Start menu choose Settings and then Taskbar and Start Menu Properties The Taskbar Properties dialog box appears 1 On the Taskbar Options tab select Show Clock 2 Tap OK An hours and minutes display now appears in the taskbar Clock Display GFK 2512 Chapter 4 Detailed Operation 4 41 4 Configuring SNTP There are two levels of Network Time Protocol NTP time servers available on the Internet First level time servers
15. are primarily intended to act as source time servers for second level time servers First level time servers may also be capable of providing mission critical time services Some first level time servers may have a restricted access policy Second level time servers are intended for general SNTP time service needs and usually enable public access It is recommended that you use second level time servers for normal SNTP time server configuration because they are normally located on a closer network that can produce faster updates It is recommended that you research any time server selection to ensure that it can meet your specific time server requirements More information and a list of SNTP time servers can be found at http support microsoft com kb 262680 If the time on the time server is more than the threshold value away from the current time on the QuickPanel View then the time is not updated Setting the Threshold to 0 tells the utility to always accept the time from the server This setting would be useful in a case where the backup battery has died and the QuickPanel View was power cycled since the internal clock would have reset back to January 1 1980 12 00 am 4 42 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 4 To set SNTP 1 In the Control Panel double tap Date Time The Date Time Properties dialog box appears Note Tap Apply after making changes in any box 2 To add or mo
16. configure your TCP IP Settings at this time if you wish 7 Tap Finish To change the default device properties 1 From either the Device or Modem dialog box tap Configure The Device Properties dialog box appears 2 In the Port Settings tab choose settings for all connection preferences 3 If the connection is for terminal emulation select or clear the terminal related check boxes You can use the QuickPanel View to emulate a terminal attached via a modem link Hayes compatible to COM1 A terminal emulation definition is added as a unique session GFK 2512 Chapter 4 Detailed Operation 4 17 4 To change the default TCP IP settings 1 Obtain correct TCP IP settings from your network administrator 2 From the Device Modem PPPoE Connection or VPN Connection dialog box tap TCP IP Settings The TCP IP Settings dialog box appears 3 Clear the Use server assigned IP address check box 4 Enter the TCP IP settings from your network administrator and then click OK 4 18 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 4 CF Port To enhance the QuickPanel View s capabilities with additional flash memory the unit is equipped with a CF Compact Flash Type 2 port on its side A CF card is inserted in this port with the card s front facing the back of the unit the narrow side slot on the card should be toward the top Note For full protection from elect
17. cutout without a CF card in the CF port 2 Insert the hook of each mounting clamp into the housing openings as shown below 3 Firmly tighten the clamp screws Note The torque range for the mounting clamp screws is 2 6 4 4 inch lbs 0 3 0 5 Nm The mounting clamps hold the unit in place by tension No drilling is required Do not damage the gasket attached to the back of the QuickPanel This gasket prevents shock hazards and damage caused by liquids accidentally entering the unit after installation Also limit the number of times you remove and reinstall the unit Too many installations may cause gasket set and degradation of the seal GFK 2512 4 1 Detailed Operation Touch Screen Display 4 1H2 Adjusting the display brightness configuring backlight auto turn off calibrating the touch screen and setting the double tap sensitivity Communication Ports 4 2H10 Description and pin assignments for the COM1 serial port cabling and working with the serial COM port CF Port 4 3H18 Using the compact flash CF port Ethernet 4 4H19 Setting an IP address Setting up access to a Windows network Accessing a remote resource on a Windows network Expansion Bus 4 5H25 Using the expansion bus to connect optional modules DIP Switches 4 6H27 Configuring startup behavior Memory 4 7H30 Adding Flash memory with a CF Card changing the DRAM memory allocation installing additional DRAM Other Subsys
18. document The license does not extend to any other product regardless of whether such product is included with this licensed product in a single article No license is granted or shall be implied for any other use Additional information may be obtained from MPEG LA L L C See http www mpegla com The FCC requires the following note to be published according to FCC guidelines This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Any changes or modifications to the product or installation that are not expressly approved by GE Fanuc could void the user s authority to operate the equipment under FCC rules Industry Canada requires the following note to be published This Class A digital apparatus complies with Canadian ICES 003 The following statements are required to appear for Class I Division Zone 2 Hazardous Locations 1 WARNING EXPLOSION H
19. herein The entire risk as to the quality and performance of such information equipment and software is upon the buyer or user GE Fanuc shall not be liable for any damages including special or consequential damages arising out of the use of such information equipment and software even if GE Fanuc has been advised in advance of the possibility of such damages The use of the information contained in the manual and the software described herein is subject to GE Fanuc s standard license agreement which must be executed by the buyer or user before the use of such information equipment or software Notices GE Fanuc reserves the right to make improvements to the products described in this publication at any time and without notice 2008 GE Fanuc Intelligent Platforms All rights reserved QuickPanel View is a trademark of GE Fanuc Intelligent Platforms in the United States and other countries Any other trademarks referenced herein are the property of their respective owners and used solely for purposes of identifying compatibility with the products of GE Fanuc The 8 QuickPanel View has been tested and found to meet or exceed the requirements of U S 47 CFR 15 Canadian ICES 003 Australian AS NZS 3548 and European EN55022 regulations for Class A digital devices when installed in accordance with guidelines noted in this manual Microsoft requires the following notes be published according to their additional licensing provisi
20. screen sensitivity run Backup When the Backup dialog box displays Completed Successfully remove power from the DC power supply connected to the QuickPanel GFK 2512 Chapter 1 Welcome 1 5 1 Technical Support If you purchased this product through a GE Fanuc Authorized Channel Partner please contact them directly General Contact Information Online Technical Support and GlobalCare 1http support gefanuc com Additional information 2Hhttp www gefanuc com Technical Support If you have technical problems that cannot be resolved with the information in this guide please contact us by telephone or email or on the web Americas Online Technical Support 3H4Hhttp support gefanuc com Phone 1 800 GE FANUC 1 800 433 2682 International Americas Direct Dial 1 434 978 5100 Technical Support Email 5Hmailto support gefanuc com Customer Care Email 6Hmailto customer care gefanuc com Primary language of support English Europe the Middle East and Africa Online Technical Support 7H8Hhttp support gefanuc com Phone 800 1 GE FANUC 800 1 433 2682 Technical Support Email 9Hmailto support emea gefanuc com Customer Care Email 10Hmailto customercare emea gefanuc com Primary languages of support English French German Italian Czech Asia Pacific Online Technical Support 1H12Hhttp support gefanuc com Phone 86 400 820 8208 86 21 3217 4826 India Indonesia and Pakistan Technical Support Email 13Hmailto
21. screws is 4 6 inch lbs Rear View Power Supply Socket Power Supply Plug Frame Ground 0 V 24 VDC GFK 2512 Chapter 3 Installation for Compliance and Conformance 3 3 3 Panel Cutout For enclosure mounting cut an opening in the panel according to the specifications Panel Cutout Height 7 34 0 050 0 0 186 4mm 1 27mm 0mm Width 8 97 0 050 0 0 227 8mm 1 27mm 0mm Depth 3 03 76 9mm Bezel Dimensions Height 8 18 207 7mm Width 9 8 248 9mm Corner Radii 0 1 2 5mm max Panel Thickness range 0 063 to 0 196 1 6mm to 5mm 7 34 186 4mm 8 97 227 8mm Installation Notes The unit will not fit through the cutout with a compact flash CF card inserted in the port The unit may not fit through the cutout with some cables attached depending on the cable s hood design 3 4 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 3 Mounting Bracket Locations To secure the QuickPanel View to a panel use the six included mounting brackets They hook into openings located on the top bottom and sides of the housing Top View Bottom View Right Side View Left Side View GFK 2512 Chapter 3 Installation for Compliance and Conformance 3 5 3 Mounting the QuickPanel View in a Panel 1 Verify that the gasket is properly seated in the bezel channel then insert the unit into the panel
22. the flash drives are highly fragmented or corrupted reads and writes to the drive can experience significant delays leading to delayed response to touch inputs Corrupted external flash drives may be corrected with Storage Manager See Storage Manager in chapter 3 After adding expansion memory in the DIMM connector the system won t boot or if it does boot an error message is displayed When the system is first started observe the screen to notice any memory error messages from the boot loader If any messages appear such as DIMM not 12 row DIMM not 32 bit DIMM refresh unsupported power down the system and remove the memory module If the error message is displayed from the Windows CE desktop also power down the system and remove the memory module For proper operation expansion memory modules must meet the requirements stated in Appendix A Specifications Touch screen does not work reliably in corners or touch areas activate just outside their borders Touch screen may need recalibration Select Start then Settings Control Panel Stylus and then the Calibration tab Follow the on screen directions Accessing the Compact Flash CF card causes the system to run slowly or hang up The CF card may be corrupted or full Delete some files or reformat the CF card Select Start then Settings Control Panel and then Storage Manager Use the buttons in the Storage Manager dialog box to f
23. with a 10BaseT 100BaseTX auto negotiate full or half duplex Ethernet port IEEE802 3 You can connect an Ethernet network cable unshielded twisted pair UTP CAT 5 to the unit via the RJ45 connector on the bottom of the enclosure LED indicators on the port indicate channel status Access to the port is possible either by Windows CE network communications or by your custom application The following diagram shows the location orientation and pin out of the Ethernet port 1 TX_D1 2 TX_D1 3 RX_D2 4 NC 5 NC 6 RX_D2 7 NC 8 NC Bottom On Packet received or transmitted On Channel OK 1 8 4 20 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 4 The QuickPanel View provides two methods for setting an IP address DHCP Dynamic Host Configuration Protocol This is the default method that is carried out automatically There must be a DHCP server on the connected network for a valid IP address to be assigned Contact your network administrator to ensure correct DHCP server configuration Manual method You uniquely specify the numeric addresses for the QuickPanel View the Subnet Mask and the Default Gateway if applicable Use a crossover cable to connect the QuickPanel View directly to a PC When connecting to a LAN HUB use a straight through cable Contact your network administrator for further information To set an IP address 1 From the Contr
24. AZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS 1 DIV 2 2 WARNING EXPLOSION HAZARD WHEN IN HAZARDOUS LOCATIONS TURN OFF POWER BEFORE REPLACING OR WIRING MODULES 3 WARNING EXPLOSION HAZARD DO NOT CONNECT OR DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR AREA IS KNOWN TO BE NON HAZARDOUS Power input and output I O wiring must be in accordance with Class I Division 2 wiring methods Article 501 10 b of the National Electric Code NFPA 70 and in accordance with the authority having jurisdiction Users must supply an isolated DC supply to power the QuickPanel models covered by this manual The power input to the QuickPanel must be limited by a slow blow fuse not to exceed a maximum 100VA For less than 20Vdc input the fuse must be rated for no more than 5A For a complete list of agency approvals please refer to Appendix A Contents GFK 2512 iii Welcome 1 1 Getting Started 1 2 Technical Support 1 5 Firmware Updates 1 6 Overview
25. Memory 4 30 Other Subsystems 4 36 Specifications A 1 Physical A 1 DC Power A 1 Display A 2 Front Panel A 2 Touch Screen A 2 CPU A 2 Memory A 3 Memory Expansion Slot A 3 Contents iv 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 Expansion Ports A 3 Communication Ports
26. View Intermediate Color TFT September 2008 GFK 2512 A Communication Ports IEEE 802 3 10 BaseT 100 Base TX Auto negotiate Full or half duplex RJ45 connector Two status LEDs Ethernet Maximum cable length 100m Serial COM1 EIA232C EIA485 DP25S female Speed 300 bps 115200 bps Mounting hardware M2 6 jackscrew Fuse 1 0A 125V fast blow cartridge type Littlefuse part 154001 GFK 2512 Appendix A Specifications A 5 A Environmental 32 F to 140 F Operating Temperature 0 C to 60 C Operating Humidity 10 to 90 non condensing 4 to 158 F Storage Temperature 20 to 70 C Storage Humidity 10 to 90 non condensing NEMA Rating 4 4x and 12 when mounted in a comparably rated NEMA panel NEMA 4 is approximately equivalent to IP66 visit www nema org IEC 60068 2 6 10 57Hz 0 012 peak to peak displacement Operational Vibration 57 500Hz 1 0g acceleration IEC 60068 2 27 Operational Shock 15g 11ms sine wave Rated temperature limits refer to the ambient air temperature immediately surrounding less than 3 or 7 6 cm the QuickPanel inside the enclosure in which the QuickPanel is mounted Additional provisions for remaining within the stated limits must be considered where additional external thermal loads are imposed on the QuickPanel These could include large heat producing motor drives or power supplies in the same cabinet or in outdoor a
27. an application call in a script The HTTP utility is an executable EXE file included in the 8 QuickPanel View operating system The HTTP utility currently supports two file transfer commands COPY and DELETE Note In order to function the HTTP File Transfer utility requires both computers to have web servers that support PUT functionality Most web servers support PUT including the Proficy Machine Edition web server installed with the runtimes for View and Logic Developer PC If in doubt check the documentation for your web server 2 20 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 2 To use the HTTP utility 1 From the Start menu choose Programs then choose Command Prompt The Command Line editor appears 2 Type commands as required 3 Use the following syntax HTTPUTIL COPY source destination Where source is the URL of the source file and destination is the URL of the destination file For example HTTPUTIL COPY MyFile txt http MyServer webfiles MyFileBACKUP txt Copies a file called MyFile txt on drive C of the local computer to the webfiles folder under the web server at MyServer Note that you can rename a file as you copy it HTTPUTIL DELETE url Where url is the remote URL of the file you want to delete This URL must use the or HTTP syntax For example HTTPUTIL DELETE http MyServer webfiles MyFileBACKUP txt De
28. ble 3 Tap Start point to Settings and then tap Control Panel 4 In the Control Panel double tap Display to configure the LCD display 5 In the Control Panel double tap Stylus to configure the touch screen 6 In the Control Panel double tap Date and Time to configure the system clock 7 In the Control Panel double tap System to configure a network machine name Many applications including Proficy Historian require a unique machine name It is recommended procedure to set a unique network name for the QuickPanel View to avoid future conflicts 1 4 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 1 8 In the Control Panel double tap Network and Dial up Connections to configure network settings 9 On the desktop double tap Backup to save any new settings through a power cycle Shutdown There are no specific dangers associated with a power failure or other unplanned shutdown of the QuickPanel View In general programs are retained in FLASH memory and user data can be retained in battery backed SRAM Some operating system settings are retained only with user intervention so in order to carry out a graceful shutdown of the QuickPanel View we recommend you perform the following procedure To shut down the QuickPanel View 1 Quit any programs that are running and wait for all file operations to complete 2 To save changes to operating system settings e g brightness touch
29. dify SNTP settings select the SNTP tab 3 To enable SNTP ensure the Enable SNTP check box is selected 4 Enter the time server name in the Server s field 5 Set the Refresh Retry and Threshold parameters 6 Tap Update Now to update SNTP settings immediately 7 Tap OK to finish 8 To save the settings run the Backup utility See page 2 11 GFK 2512 A 1 Specifications See page A 0H6 for a list of agency approvals for environmental service and safety Physical Height 7 34 in 186 4 mm Width 8 97 in 227 8 mm Enclosure dimensions actual see Getting Started in chapter 1 for cutout dimensions Depth 3 03 in 76 9 mm Height 8 18 in 207 7 mm Width 9 80 in 248 9 mm Bezel dimensions Depth 0 35 in 9 mm Weight 4 lb 1 8 kg DC Power Input Voltage 10 8 to 30 0 VDC Real Power 24 W Power Supply Conductor Size 12 to 18 AWG For compliance to CE Mark the isolated frame ground must be connected Recommended frame ground connection is via the shortest possible route using 14 AWG Connector Vendor p n Phoenix Contact 1834916 Note The torque range for the attaching screws is 4 to 6 inch lbs Appendix A A 2 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 A Display Size 8 4 21 3 cm diagonal Colors 65 536 Resolution 800 x 600 pixels Fabrication TFT Backlight Cold Cathode Fluorescent CCFL
30. e double tap sensitivity 1 In the Control Panel double tap Stylus The Stylus Properties dialog box appears 2 Choose the Double Tap tab 3 Double tap the grid to enter a setting 4 Double tap the test icon to check the setting If the test icon doesn t change when you double tap it double tap the grid again 5 Tap OK to finish 6 To save the settings run the Backup utility See page 2 11 4 10 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 4 Communication Ports The QuickPanel View has one serial data communication port COM1 COM1 Serial The COM1 port is a general purpose bidirectional serial data channel that supports the EIA232C and EIA485 electrical standards The COM1 port can be accessed and configured as a direct or dial up remote networking connection from a user created application utility A connection can be configured to reside on a network supporting a TCP IP protocol A DB25S female connector mounted on the bottom of the enclosure provides standard signals as described in the following table 1 GND Frame Ground 14 VCC 5VDC 0 5A 2 TX EIA232C 15 TXB EIA485 3 RX EIA232C 16 RXB EIA485 4 RTS EIA232C 17 n c 5 CTS EIA232C 18 CSB EIA485 6 DSR EIA232C 19 ERB EIA485 7 SG Signal Ground 20 DTR EIA232C 8 DCD EIA232C 21 CSA EIA485 9 TRMRXB EIA485 22 ERA EIA485 10 RXA EIA485 23
31. e memory 2 Overview 2 23 2 All removable flash devices appear to remote FTP users as directories off the FTP root directory PC Flash card partitions appear as directories such as PCFlashStorage The names contain no spaces as FTP commands do not support spaces in filenames Full access privileges are granted for the client in these folders devices Removable flash device directories are captured when a session is opened and are not changed while the session exists If you start without a CF card installed you will have to close your session and login again to see the CF directory If the CF card existed when you logged in and is removed and inserted it will still work provided the CF card s device name did not change during reinsertion A server certificate is a special type of document that contains information about the server s settings and a chain of electronic signatures to guarantee the document has not been altered A Server certificate must be chosen from the certificates available in the QuickPanel View Secure FTP Server control panel applet The certificate itself is imported with the Certificates control panel applet The main requirements of the certificate are that it must have the server authentication key usage attribute set and the name of the certificate should match the name used to connect to the FTP server which could be the IP address of the server Certificates can either be purchased from an onli
32. el Always use anti static precautions i e grounded wrist strap when accessing the interior of the unit Caution Ensure all pins are properly aligned when inserting expansion cards Misalignment could cause damage to the QuickPanel View and or the expansion card Caution Do not allow conductive material liquid or solid to contact the electronics of the QuickPanel 4 26 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 4 Expansion Bus Connectors Note To ensure compliance to CE Mark the mounting screws must be used when installing an expansion card GFK 2512 Chapter 4 Detailed Operation 4 27 4 DIP Switches The QuickPanel View is equipped with four DIP switches that control separate functions DIP switches are set to OFF by default in the factory DIP switch 2 is the Force Startup switch Turning this switch on forces the startup applications to run when the operating system is started DIP Switches On Off 1 2 3 4 4 28 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 4 When the switch is set to OFF the QuickPanel View operates normally displaying the startup splash screen You can skip running the startup applications by tapping the Don t run StartUp Programs button on the startup splash screen When the switch is set to ON the startup programs are forced to run and the Don t run Star
33. en there is only one flash device present 3 Tap Yes when the Copy Project Query confirmation dialog box appears The system copies the project onto the flash device Caution Creating a project copy while the Machine Edition runtimes are active may cause an incomplete copy to be created if the runtimes are also writing to files in the project folders The utility can detect this situation and will warn you to stop the runtimes before making the backup You will not be able to create a backup while the runtimes are writing files 2 16 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 2 To update a Machine Edition project You can update a Machine Edition application currently stored on the QuickPanel View with a revision stored on a flash device such as a CF card or PCMCIA flash 1 Insert the flash device containing an upgraded version of the Machine Edition project into the appropriate port 2 Reboot the machine see page 2 8H14 See the settings section below as depending on options set the update may or may not be enabled or may automatically update If there is more than one flash device with a valid project copy present a Select Media confirmation dialog will appear allowing you to choose which flash device to update with Select the device from the list and select OK to continue When a valid project is found on the flash device you will be prompted to install the project or skip i
34. er to divide the DRAM into Storage and Program memory The amount of memory allocated to and used by each area is shown on the dialog box The amount of memory allocated to and used by each area is displayed numerically The blue bar indicates the current amount of unallocated DRAM and determines the boundaries within which the slider can move 3 Tap OK to apply the new setting 4 To save the settings run the Backup utility See page 2 11 Boot Loader ROM The Boot Loader ROM provides 512 KB of non volatile storage for the QuickPanel View s initialization program This program configures the QuickPanel View hardware then starts the operating system s execution This memory is not accessible from Windows CE Explorer nor should any attempts be made to modify the contents of this ROM 4 34 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 4 Memory Expansion Slot The QuickPanel View is equipped with a 100 pin DIMM memory expansion slot which lets you increase DRAM to a total of 96 MB Memory Expansion Slot Caution Disconnect power from your DC power supply before opening the QuickPanel View Working on a live unit may result in damage to equipment and injury to personnel Always use anti static precautions when accessing the interior of the QuickPanel View GFK 2512 Chapter 4 Detailed Operation 4 35 4 Caution Do Not Allow conductive material liquid or solid t
35. factors Termination Always provide proper termination at each end of the 422 485 network The QuickPanel View provides built in termination resistance when pin 9 TRMRXB is connected to pin 10 RXA Caution Do not terminate every node Only terminate the end nodes 4 12 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 4 Grounding A signal return path between transmitting and receiving devices must be provided This return path is separate from the Rx and Tx data lines and the other 422 485 signals supported by the QuickPanel View and may be provided by a separate conductor in the cable Connect both ends of the signal return conductor to Signal Ground pin 7 Shielding or use of a twisted pair for this connection is not necessary For installations where all devices are in the same cabinet and have the same ground potential between devices connecting Signal Ground between all the devices on the 422 485 network is adequate to ensure proper voltage levels at the devices However if there is a difference in ground potential between devices such as when the devices are in widely separated cabinets signal grounds on a 422 485 network should not be tied together The cable shield and signal ground should be connected together at only one device closest to the earth ground connection The signal and frame grounds of the QuickPanel View are capacitively coupled but in some devices these ground reference
36. gs run the Backup utility See page 2 11 GFK 2512 Chapter 4 Detailed Operation 4 5 4 Touch Screen The QuickPanel View display is coupled to a resistive touch panel with 12bit resolution When the QuickPanel View is properly calibrated this translates into a grid of touch cells on the face of the display A blunt stylus should always be used during calibration for greatest accuracy During normal operation use of a finger or a soft and pliable blunt object is recommended to preserve the maximum reliability of the touch screen 600 pixels 800 pixels 4 6 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 4 To calibrate the touch screen 1 In the Control Panel double tap Stylus The Stylus Properties dialog box appears 2 Choose the Calibration tab GFK 2512 Chapter 4 Detailed Operation 4 7 4 3 Tap the Recalibrate button A cross hair target is displayed Note For greatest accuracy it is recommended that you use a blunt stylus when calibrating the touch screen 4 Follow the directions given to calibrate the touch screen 4 8 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 4 5 Tap the screen to preserve the new setting or wait out the time limit to revert to previous settings 6 To save the settings run the Backup utility See page 2 11 GFK 2512 Chapter 4 Detailed Operation 4 9 4 To set th
37. he interior of the QuickPanel View Caution Do not allow conductive material liquid or solid to contact the electronics of the QuickPanel Battery Power Connector 4 38 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 4 To remove the internal battery 1 Disconnect power from the DC supply 2 Open the rear access panel 3 Release the battery by gently lifting it from the completely exposed side past the small protrusions To avoid breaking the battery retainer clips do not apply excessive upward pressure 4 Slide the battery out of its carrier noting the arrow on the carrier indicating the direction of removal To install a new battery 1 Disconnect power from the DC supply 2 Open the rear access panel Note Battery must be installed with positive side up 3 To install the battery insert one side of battery into upper side of battery clip then press other side into clip until snaps into place Warning Replace battery with Panasonic BR2032 only Use of another battery may present a risk of fire or explosion Warning Battery may explode if mistreated Do not recharge disassemble or dispose of in fire GFK 2512 Chapter 4 Detailed Operation 4 39 4 Real time Clock The QuickPanel View has a programmable real time clock capable of reporting the current time in Year Month Day Hour Minute Second The time is set from the Windows CE interface
38. iate Color TFT September 2008 GFK 2512 2 Reboot Reboot performs a controlled and orderly shut down of the Windows CE operating system then restarts the QuickPanel View This ensures all open files are closed properly To reboot the system 1 To save changes to system configurations run Backup see page 2 7H11 2 Tap Start point to Programs then the System folder and tap Reboot A confirmation dialog box appears 3 Tap Yes The operating system reboots 2 Overview 2 15 2 Copy Project to Flash Card RestorePCCard is a custom utility for transferring Proficy TM Machine Edition Projects between compatible QuickPanel View units via CF cards or PCMCIA flash if the unit is fitted with the optional PCMCIA interface expansion card Flash memory not included with PCMCIA expansion card Caution Ensure that the copy or update operation is complete i e no busy or wait cursor displays before disconnecting power To copy a Machine Edition project onto a flash device 1 Ensure there is a blank flash device in the in the appropriate port 2 Double tap the Copy Project to Flash Card icon on the desktop If there is more than one of the supported flash devices installed a Select Media confirmation dialog will appear allowing you to choose the destination location for the backup From the drop list choose the destination and then select OK to continue This dialog does not appear wh
39. ickPanel View Intermediate Color TFT September 2008 GFK 2512 4 or 6 From the list choose the device or modem you want to use If a serial CF card is inserted it is available in the device list You can configure your device or TCP IP Settings at this time if you wish 7 Tap Finish for direct connection Device dialog box or Next for dial up Modem dialog box If you are adding a dial up connection the following dialog box appears 8 Type the destination Country region code Area code and Phone number in the appropriate boxes 9 Select or clear the Force Long Distance or Force Local check boxes 10 Tap Finish GFK 2512 Chapter 4 Detailed Operation 4 15 4 To add a virtual private network or PPP over Ethernet 1 From the Start menu tap Settings and then Network and Dial up Connections The Connection window appears 2 Double tap Make New Connection The Make New Connection window appears 3 Type a name for the new connection 4 Choose a connection type Select Virtual Private Network to configure a VPN connection Select PPP over Ethernet for a PPPoE connection 5 Tap Next The VPN or PPPoE Connection window appears depending on the connection type or 4 16 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 4 6 Enter the Host Name or IP address for a VPN connection or a PPPoE Service Name for a PPPoE connection You can
40. ing power while writing may lead to data loss and file system corruption To ensure the system completes writing to flash and closes all files see Shutdown in chapter 1 To add Flash memory with a CF Card Insert a Compact Flash card into CF Port see page 3 9H18 The unit immediately reads the new secondary storage If the disk requires formatting you will be prompted to do so New memory appears in Windows CE Explorer as PCFlash Storage External flash memory devices are named after their types of connection and order of attachment For example if you connect two flash memory devices one via the CF port and one via the FieldBus connector the first device connected is named PCFlash Storage the second PCFlash Storage2 At powerup a CF port device is recognized and named first Otherwise name depends on connection order SRAM Memory This 512 KB block of static RAM is battery backed to provide data retention through a power cycle This memory block is shared by the operating system and user applications A portion of the SRAM memory operates as a virtual hard drive and is accessible from the Windows CE Explorer It is represented as the SRAM Storage folder A typical application program would create a file in this folder and store critical program data in that file The portions of SRAM used by the operating system and by user applications varies between models 4 32 8 QuickPanel View Intermediate Color TFT
41. le memory is the main long term program storage for the QuickPanel View operating like a virtual hard drive from the point of view of Windows CE It is divided into two areas of which only one is accessible from Windows CE Explorer The Flash Storage folder represents a 16 MB block of memory available for long term storage of user application programs Another 16MB block is used to store the Windows CE operating system and is not directly accessible from Windows CE Explorer The operating system and all user application programs are transferred from Flash to DRAM for execution Any user additions to the Windows folder are retained in Flash Storage when the Backup utility is run FLASH memory has a limited write cycle lifetime That is the physical memory devices wear out after approximately 100 000 cycles minimum so it is advisable to limit file operations such as copy delete etc The write cycle is much slower for FLASH than it is for other portions of RAM therefore FLASH is not recommended for the storage of program variables or any data items whose values are dynamic Flash memory can optionally be added with an external flash device such as a CF card or PCMCIA flash These devices will appear as the PCFlash Storage folder GFK 2512 Chapter 4 Detailed Operation 4 31 4 Caution Do not remove power while the system is writing to flash memory such as when downloading a Proficy Machine Edition project Remov
42. letes a file called MyFileBACKUP txt from the webfiles directory under the web server at HTTP MyServer 2 Overview 2 21 2 FTP Server The FTP Server included with the QuickPanel View supports both standard RFC 959 and Explicit FTPS i e FTP SSL Auth TLS TLS C RFC 4217 It does not support SFTP or implicit FTPS which uses different ports and is based on SSH rather than SSL All configuration of the FTP server is accomplished with the Secure FTP Server control panel applet By default the server is not enabled Once enabled a background program will run waiting for clients to connect Up to ten connections are supported Sessions that are idle for five minutes are terminated by the server Note To save the settings run Backup see page 2 10H11 2 22 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 2 The Server supports Non secure operation All information including username password and data is transmitted with no encryption and susceptible to packet sniffing and various FTP attacks This is the default Both secure and non secure operation This mode of operation either secure or non secure is determined by the client when it connects This operation is active when Support Secure Connection is enabled but Required is not Secure operation only Secure operation uses encrypted connections for the control connection The data connections are encrypted
43. n c 11 TXA EIA485 24 n c 12 n c 25 n c 13 n c Note Pin 14 is fused with a field replaceable 1 0A fast blow fuse GFK 2512 Chapter 4 Detailed Operation 4 11 4 Recommended Cabling for TIA EIA422 or TIA EIA485 The COM1 port on the QuickPanel View provides connections to devices that support either TIA EIA422 or TIA EIA485 These electrical standards specify a differential signaling technique that provides high data rates long distances and good noise rejection The standards do not address signal encoding protocol connectors or cabling However certain characteristics of these devices interfaces should be considered to ensure reliable connections Connections Connect nodes in a daisy chain fashion Do not connect in other arrangements especially star The standards do not specify the maximum number of nodes or devices that can be connected to a TIA EIA 422 or 485 network Instead the standards limit the number of electrical connections by specifying that a maximum of 32 unit loads may be connected The QuickPanel View presents one unit load Interconnect media Always use twisted pair cabling and group complimentary signals into conductor pairs TXA with TXB for example Use a cable with a characteristic impedance of 100 ohms to 120 ohms A wire gauge of 24 AWG is commonly used Maximum cable length is 4 000 1 219 2m but may be less due to cable impedance connection quality data rates and other
44. ne vendor and imported into the QuickPanel View or a self signed certificate can be generated from the QuickPanel View The benefit of a purchased certificate is that any user that has the root certificate used by the online vendor can determine the certificate is valid without the need for any additional information A self signed certificate 2 24 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 2 is only known to be valid by clients that have added the certificate to their trusted list Users can still access a server using a self signed certificate but they lose the ability to verify that no one is operating as an imposter somewhere on the network between them and the server To create a self signed certificate 1 Open a command prompt window by selecting the Start menu selecting Programs then Command Prompt 2 From the command prompt type genslfcert CN lt unique identifier gt You may specify a unique identifier of your choice such as machine name machine location or IP address in place of unique identifier 3 A self signed certificate is created in the My Certificates section of the certificates Control Panel This will create a self signed certificate in the My Certificates section of the certificates control panel and a SelfSigned cer file in My Computer which can be transferred to FTP Clients as a trusted source Certificates may be managed through snap ins to the Microsoft
45. o contact the electronics of the QuickPanel To install additional DRAM 1 Disconnect power from the DC supply 2 Open the rear access cover 3 Insert the new DIMM carefully into the expansion slot noting the orientation of the pin locators When the DIMM is fully seated lift each side clip until it clicks into place 4 36 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 4 Other Subsystems Power Management The QuickPanel View s Power Properties control panel displays the status of the backup battery The Battery Very Low Or Missing icon appears in the taskbar when the battery is either missing or very low To access the Power Properties control panel 1 In the Control Panel double tap Power The Power Properties dialog box appears Battery Backup Auxiliary backup power for the real time clock and SRAM is provided by a non rechargeable internal lithium battery 3VDC BR2032 ensuring that no loss of data occurs when the main DC supply is removed Backup power is enabled or disabled by installing or removing the battery accessed via the rear panel as shown in the following illustration GFK 2512 Chapter 4 Detailed Operation 4 37 4 Caution Disconnect the power from your DC power supply before opening the QuickPanel View Working on a live unit may result in damage to equipment and injury to personnel Always use anti static precautions when accessing t
46. ol Panel tap Network and Dial up Connections The Connection window appears 2 Select a connection and choose Properties The Built in Ethernet Port Settings dialog box appears GFK 2512 Chapter 4 Detailed Operation 4 21 4 1 Select a method Obtain an IP address via DHCP automatic Specify an IP address manual 2 Enter the IP Address Subnet Mask and Default Gateway numbers obtained from your network administrator manual method only 3 Tap OK 4 To save the settings run the Backup utility See page 2 11 If the DHCP method was selected the network server will assign an IP address while the QuickPanel View is initializing You must be connected to the network After setting an IP address for the QuickPanel View you can access any network drives or shared resources for which you have permission 4 22 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 4 To set up access to a Windows network 1 In the Control Panel double tap System The System Properties dialog box appears 2 On the Device Name tab in the Device name box type a unique name for your QuickPanel View In the Device description box type a description 3 Tap OK 4 In the Control Panel double tap Owner The Owner Properties dialog box appears GFK 2512 Chapter 4 Detailed Operation 4 23 4 5 On the Network ID tab type your User name Password and Domain 6
47. onality with other versions of Windows simplifies porting your existing program code Another benefit of Windows CE is the familiarity of the user interface shortening the learning curve for operators and developers alike The availability of third party application software makes this operating system even more attractive The 8 QuickPanel View is an all in one microcomputer designed for maximum flexibility The design based on an advanced Marvell microprocessor brings together a high resolution touch screen operator interface with a variety of I O options With many standard ports and expansion busses from which to choose you can connect to most industrial equipment The QuickPanel View is equipped with several memory types to satisfy even the most demanding applications A 32 MB section of DRAM is split between the operating system an object store and application memory Functioning as a virtual hard drive a 32 MB section of non volatile FLASH memory is divided between the operating system and persistent storage for application programs The retentive memory consists of 512 KB of battery backed SRAM for data storage ensuring your valuable data will never be lost even during a power failure The many features of the QuickPanel View make it an obvious choice for a world of applications Your smart choice will provide reliable operation for years to come Chapter 1 1 2 8 QuickPanel View Intermediate Color TFT September 2008
48. ons Users are advised that a maximum of ten 10 computers or other electronic devices may simultaneously connect to access and use services of the Microsoft Windows CE Operating system on the QuickPanel View solely for remote access including connection sharing The ten connection maximum includes any indirect connections made through multiplexing or other software or hardware which pools or aggregates connections Note that the QuickPanel View does not provide any server functionality utilizing Remote Desktop Protocol RDP to remotely connected client computers or devices However it does support connectivity to a remote Microsoft Terminal Services server The server providing these services must meet these restrictions and other Microsoft licensing requirements as applicable Notices Notice Regarding Video Standards This product is licensed under one or more video patent portfolio licenses such as and without limitation VC 1 and MPEG4 Part 2 Visual for the personal and non commercial use of a consumer to i Encode video in compliance with the standards licensed under such patent portfolio licenses and or ii Decode video that was encoded by a consumer engaged in a personal and non commercial activity and or was obtained from a video provider licensed to provide video under such patent portfolio licenses Such license extends to this product only and only to the extent of other notices which may be included in this
49. or non encrypted based on the settings of the client Secure operations also require the server to have a signed server certificate it can use to prove it is the actual machine the client wanted to reach and not an imposter This mode is active when both Support Secure Connection and Required are enabled By default the server requires a username password combination to be configured The server supports one username password combination to authenticate remote users There are three modes of authentication operation No support for anonymous login This is the default Anonymous with no password This is enabled when Allow Anonymous Access is checked but Require Username and Password is not checked Anonymous with password requested but not validated This is enabled when Allow Anonymous Access and Require Username and Password are checked This can prevent some types of attacks and is required by some clients Once connected a remote user is logged into the FTP root directory This is available from the QuickPanel View as Temp ftp and is a volatile RAM area Files placed in this area are not persisted over a power cycle reboot and use memory from the Storage Memory allocation For this reason remote users are only able to read rename and delete files from the FTP root directory Programs running on the QuickPanel can access the Temp ftp like any other folder but remote users cannot fill up storag
50. ormat or scan the CF card Index GFK 2512 Index 1 A Agency Approvals A 6 B Backup 2 11 Basic setup 1 2 Battery removing 4 38 specifications A 5 Battery backup 4 36 Battery Backup 4 36 Block diagram 2 5 Boot loader ROM 4 33 C Calendar clock specifications A 5 CF card copying a project to 2 15 CF port operation 4 18 Clock operation 4 39 setting 4 39 Communication ports operation 4 10 specifications A 4 CPU specifications A 2 Cutout panel 3 3 D Diagnostics B 1 Dial up connection configuring 2 8 Dimensions bezel A 1 module A 1 panel cutout 3 3 DIP Switches 4 27 Display operation 4 2 specifications A 2 DRAM adding 4 35 DRAM memory 4 32 E Emulate PPC 2 19 Environmental requirements A 5 Ethernet ports operation 4 19 Expansion bus 4 25 Expansion memory diagnostics B 2 Expansion ports specifications A 3 F Flash memory adding 4 31 operation 4 30 Front panel specifications A 2 FTP Server 2 21 G Getting started 1 2 H HTTP File Transfer Utility 2 19 I IP address setting 4 20 Index Index 2 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 L LAN connection 2 9 Layout diagram 2 2 M Machine Edition project updating 2 16 Memory 4 30 specifications A 3 Memory expansion slot 4 34 specifications A 3 O Operating system 2 6 P Panel cutout 3 3 Physical unit diagnos
51. pears 3 On the Connection tab select the Use LAN check box 4 Tap OK 5 To save the settings run Backup see page 2 5H11 2 10 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 2 To configure a Proxy server 1 Start Pocket Internet Explorer 2 From the Tools menu choose Options The Internet Options dialog box appears 3 On the Connection tab select the Access the Internet using a proxy server check box 4 In the Address box type the URL of your proxy server see your ISP or network administrator 5 In the Port box type the server s port number for HTTP access 6 Select the Bypass Proxy for Local Addresses check box to connect directly to sites like your intranet 7 Tap OK 8 To save the settings run Backup see page 2 6H11 2 Overview 2 11 2 Backup Backup saves changes that you make to the Windows Registry or Desktop to Flash memory This utility is required because the QuickPanel View is not battery powered Specifically Backup does the following It stores the Windows CE registry including any control panel settings in Flash memory It stores any changes or additions made to the Windows subtree of the file system in the user block of FLASH memory Run Backup whenever you make configuration changes to the operating system or installed applications and prior to shutting down the QuickPanel View To run the Backup prog
52. pplications involving direct sun exposure Battery Type Panasonic BR2032 3V 190mAh lithium Approximate 5 years Calendar Clock Resolution 1 second Accuracy 2 to 3 minutes per month Retention Life of battery A 6 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 A Agency Approvals Model number ES0821 QuickPanel View Station is intended for industrial environments and when properly installed shall comply with the following agency approvals Description Agency Standard or Marking Comments North American Safety for Hazardous Locations Class I Div 2 Groups A B C D UL 1604 C UL Certification by Underwriter s Laboratories to UL standard and equivalent CSA standard Enclosures for Electrical Equipment UL 50 Certification by Underwriter s Laboratories to Type 4 4X Explosive Atmospheres Directive European Safety for Hazardous Locations Equipment Group II Category 3 ATEX when mounted in an IP66 enclosure Certification in accordance with European directives refer to Declaration of Conformity Low Voltage Directive European Safety for Industrial Control Equipment CE Self declaration in accordance with European directives refer to Declaration of Conformity Electromagnetic Compatibility Directive European EMC for Industrial Control Equipment CE Certification in accordance with European directives refer to Declaration of Conformity
53. ram 1 On the desktop double tap Backup The Backup dialog box appears 2 Tap OK 2 12 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 2 Storage Manager Use Storage Manager to repair or format lost or corrupted data volumes Data volumes existing in the main flash file system of the QuickPanel may not be repaired by Storage Manager Storage Manager accessed from the Control Panel folder is a Microsoft product for which on line help is available 2 Overview 2 13 2 System Information System Information is a custom utility that displays a splash screen with the following information Operating System version For example Windows CE 5 00 Platform Identifies the host hardware its version and build number Tapping More Info on the splash screen opens the Advanced System Information window which provides information such as hardware version and serial number CPU type and specifications etc This information can be especially useful if you are contacting GE Fanuc Support To run the System Information program 1 On the desktop double tap System Information The System Information splash screen appears 2 Tap More Info to open the Advanced System Information window or tap Close to continue Network information alone can be viewed by double tapping the LAN icon displayed on the taskbar for each connection 2 14 8 QuickPanel View Intermed
54. rostatic discharge peel off the paper label on the side of the CF card facing the bezel to allow contact between the card and the internal frame ground contacts on the CF connector The card should slide in easily To avoid damage do not force it The Copy Project to Flash Card utility described in chapter 2 lets you transfer Proficy Machine Edition projects between QuickPanel View units using CF Cards The CF port in the 8 QuickPanel View supports 3 3V CF cards No Compact Flash cards are supplied with the QuickPanel View A list of cards and other devices that have been tested and are compatible can be found by visiting 0Hhttp support gefanuc com selecting the Operator Interface category and then selecting the QuickPanel View product name An optional CF card may be ordered using part number IC754ACC0512MEM Caution Do not remove power while the system is writing to the CF card such as when copying a Proficy Machine Edition project Removing power while writing may lead to data loss and file or CF card corruption To ensure the system completes writing to flash and closes all files after file operations that were activated from the desktop allow the Windows file progress dialog to finish or indicate the operation is complete If the View applications are running see Shutdown in chapter 1 Right Side CF Port GFK 2512 Chapter 4 Detailed Operation 4 19 4 Ethernet The QuickPanel View is equipped
55. s Programs folder 6 From the Edit menu choose Paste Shortcut 7 To save the settings run Backup see page 2 3H11 2 8 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 2 Pocket Internet Explorer Microsoft s Pocket Internet Explore is a fully integrated browser within the Windows CE operating system This browser allows you to connect with an Internet service provider view web pages and download from FTP sites Pocket Internet Explorer supports JScript Java support can be added from third party sources Pocket Internet Explorer does not support VBScript however VBScript components are included in the operating system and may be used by third party applications such as Proficy Machine Edition A connection can be established over a dial up connection default or an Ethernet network The Ethernet or dial up connection must first be properly configured To configure a dial up connection 1 Start Pocket Internet Explorer 2 From the Tools menu choose Options The Internet Options dialog box appears 3 On the Connection tab select the dial up connection from the Autodial name box This example uses a connection named MyISP 4 Tap OK 5 To save the settings run Backup see page 2 4H11 2 Overview 2 9 2 To configure a LAN Connection 1 Start Pocket Internet Explorer 2 From the Tools menu choose Options The Internet Options dialog box ap
56. s are connected together Connect Signal Ground pin 7 to Frame Ground pin 1 and then to earth ground on the QuickPanel View only in the circumstance where the other devices separate their signal and frame grounds and the QuickPanel View is the only device with frame and signal ground connected to earth ground Shielding Shielded cable is required for compliance with CE Mark and FCC requirements The cable shield should be connected to the metal connector shell or by pin 1 of the QuickPanel 25 pin serial connector Shield and signal ground pin 7 of the 25pin connector or pin 5 of the 9 pin serial connector should not be connected directly together Caution Do not connect Signal Ground pin 7 to Frame Ground pin 1 on the QuickPanel View except in the specific and limited circumstances noted in the Grounding section above GFK 2512 Chapter 4 Detailed Operation 4 13 4 Working with the COM port To add a new remote networking connection 1 From the Start menu tap Settings and then Network and Dial up Connections The Connection window appears 2 Double tap Make New Connection The Make New Connection window appears 3 Type a name for the new connection 4 Choose a connection type If you are configuring a modem choose Dial Up Connection If you have a device select Direct Connection 5 Tap Next The Modem or Device dialog box appears depending on the connection type 4 14 8 Qu
57. sed implied or statutory with respect to and assumes no responsibility for the accuracy completeness sufficiency or usefulness of the information contained herein No warranties of merchantability or fitness for purpose shall apply The following are trademarks of GE Fanuc Intelligent Platforms Inc Alarm Master Genius ProLoop QuickPanel VersaPoint CIMPLICITY Helpmate PROMACRO QuickPanel View VersaPro CIMPLICITY 90 ADS Logicmaster PowerMotion QuickPanel VuMaster CIMSTAR Modelmaster PowerTRAC Series Six Workmaster Field Control Motion Mate Series 90 Series Three GEnet PACSystems Series Five VersaMax Proficy Series One Copyright 2008 GE Fanuc Intelligent Platforms Inc All Rights Reserved Notices All rights reserved No part of this publication may be reproduced in any form or by any electronic or mechanical means including photocopying and recording without permission in writing from GE Fanuc Automation Disclaimer of Warranties and Liability The information contained in this manual is believed to be accurate and reliable However GE Fanuc assumes no responsibilities for any errors omissions or inaccuracies whatsoever Without limiting the forgoing GE Fanuc disclaims any and all warranties expressed or implied including the warranty of merchantability and fitness for a particular purpose with respect to the information contained in this manual and the equipment or software described
58. support cn gefanuc com China 14Hmailto support jp gefanuc com Japan 15Hmailto support in gefanuc com remaining Asia customers Customer Care Email 16Hmailto customercare apo gefanuc com 1 6 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 1 Firmware Updates Updates to the QuickPanel firmware will be made available through the Support web site 17Hhttp support gefanuc com This will allow updating the unit to the most recent released version of the firmware with the latest feature updates and defects addressed GFK 2512 2 1 Overview This chapter provides introductory information on the 8 QuickPanel View hardware and software with procedures for completing some of the most common tasks you will encounter In this chapter QuickPanel View Hardware 2 1H2 Provides a layout diagram showing user accessible controls and indicators and a block diagram showing module functions QuickPanel View Software 2 2H6 Working with Windows CE working with Pocket Internet Explorer backing up registry or desktop changes rebooting the system using Storage Manager and System Information utilities copying projects to the Flash Card updating a Machine Edition project from the CF card emulating a Pocket PC and using the HTTP File Transfer Utility Chapter 2 2 2 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 2 QuickPanel View Hardware Layo
59. t Tap OK to install or Cancel to skip the install and continue to boot If an invalid project is found an error message appears in a dialog box This dialog box must be closed before boot will continue 3 Remove the flash device from the port 2 Overview 2 17 2 To change utility settings This utility can be configured to change the way the Machine Edition project update will occur 1 Tap Start point to Settings and then tap Control Panel 2 In the Control Panel double tap Project Transfer to configure the RestorePCCard utility settings 3 Select from the list which option you wish to use Wait for Answer This is the default setting If an update image is present the user will be prompted to install this update as described above If the update dialogs are not closed the unit will not complete the boot cycle Always Restore With this setting there will be no prompts to confirm installing the update if one is present The update will occur as though the user selected the option to install the update Note If more than one update is found due to multiple flash devices having valid update images the user will still have to select which image to use For fully automatic updates ensure there is only one update image present Skip at Startup With this setting all update images are ignored during the boot 2 18 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 2
60. tems 4 8H36 Accessing the Power Properties control panel removing and replacing the internal battery setting the real time clock and displaying the time on the taskbar Chapter 4 4 2 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 4 Touch Screen Display The QuickPanel View has an integrated flat panel display providing 16 bits per pixel for a total of 65 536 colors The backlit 8 4 inch diagonal panel employs TFT technology to provide a bright operator interface The display supports a resolution of 800 by 600 pixels A backlight timer is featured on all models You can extend the backlight life by turning off the backlight automatically 600 pixels 800 pixels GFK 2512 Chapter 4 Detailed Operation 4 3 4 To adjust the display brightness 1 In the Control Panel double tap Display and choose the Brightness tab The Brightness dialog box appears 2 Drag the Brightness slider between Lowest and Highest 3 Tap OK to exit the control panel 4 To save the settings run the Backup utility See page 2 11 4 4 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 4 To select backlight auto turn off 1 In the Control Panel double tap Display and choose the Backlight tab The Backlight dialog box appears 2 Select Auto turn off backlight while on external power 3 Tap OK to exit the control panel 4 To save the settin
61. tics B 2 Pocket Internet Explorer 2 8 diagnostics B 1 Power management 4 36 Power requirements A 1 Power supply connecting 3 2 Power up diagnostics B 1 Proxy server configuring 2 10 R Reboot 2 14 Remote resource accessing 4 24 Runtime setup 1 2 S Shutdown 1 4 SNTP setting 4 41 Software 2 6 Specifications A 1 SRAM memory 4 31 Startup behavior configuring 4 29 Storage Manager 2 12 System Information 2 13 T Technical support 1 5 Touch response diagnostics B 2 Touch Screen Display operation 4 2 Troubleshooting B 1 U Utility settings changing 2 17 W Windows network access 4 22
62. tup Programs button is not available on the startup splash screen Note Do not adjust switches other than switch 2 They are reserved for factory functions Also note that the Off position of the switches is toward the DIMM connector On toward the COM1 connector GFK 2512 Chapter 4 Detailed Operation 4 29 4 To configure startup behavior Caution Disconnect power from your DC power supply before opening the QuickPanel View Working on a live unit may result in damage to equipment and injury to personnel Always use anti static precautions i e grounded wrist strap when accessing the interior of the unit Caution Do not allow conductive material either liquid or solid to contact the electronics of the QuickPanel 1 Open the back cover of the QuickPanel View 2 Locate the DIP switches and set DIP switch 2 to ON The startup applications are now forced Note Do not adjust the other switches They are reserved for factory functions 4 30 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 4 Memory The QuickPanel View supports a variety of memory subsystems to ensure the requirements of your application are met All system memory is tied directly to the microprocessor s address and data busses for fastest access To increase DRAM by up to 64 MB a 100 pin DIMM memory expansion slot is also included Flash Memory This 32 MB block of non volati
63. ut Diagram In addition to the primary touch screen interface the 8 QuickPanel View supports a variety of communication ports including an expansion bus to allow great flexibility in application The back of the QuickPanel opens allowing access to the expansion bus connector memory expansion connector DIP switches and battery The following diagram shows the physical layout of the QuickPanel View and the locations of ports and connections Caution Remove power from the QuickPanel View before opening the back Working on a live unit may result in damage to equipment and injury to personnel Always use anti static precautions i e grounded wrist strap when accessing the interior of the unit Do not allow conductive material liquid or solid to contact the electronics of the QuickPanel The right LED is tricolor green red or amber and programmable The left LED is green when power is applied and red if either backlight fails Note Backlights are not field replaceable 2 Overview 2 3 2 Rear View with Back Panel Open Battery Power Connector Expansion Bus Connectors DIP Switches Memory Expansion Slot 2 4 8 QuickPanel View Intermediate Color TFT September 2008 GFK 2512 2 Physical Layout of QuickPanel View Front Right Side Bottom Touchscreen LCD Display CF Port LEDs RS232 485 Port COM1 Ethernet Port 2 Overview 2 5 2 Block Diagram The 8
Download Pdf Manuals
Related Search
Related Contents
USER`S MANUAL DMR-6780 Olympus VG-160 Epson WP-4010 Notice User Guide for Authorised Bidders – Sep 2006 York Sunline 2000 User's Manual operação do sistema interligado nacional durante o ano novo Samsung SMX-K40LP Užívateľská príručka Grindmaster GPOD User's Manual Copyright © All rights reserved.