VENTILATION SERVO

image

Contents

1. 31 cm 12 1 diagonal Pulse duration 6 ms Viewing area 246 0 x 184 5 mm Number of impacts 1000 Storage temperature 25 to 60 13 to 140 F Storage Relative 9596 Humidity Storage Atmospheric 470 to 1060 hPa Pressure TECHNICAL SPECIFICATIONS SERVO s Inlet gas pressure Connection standards available Unavailable gas loss of gas pressure 200 650 kPa 2 0 6 5 bar 29 94 PSI AGA DISS NIST or French standard The flow from an unavailable gas Air or O is automatically compensated for so that the patient gets the preset volume and pressure Patient system gas connectors Conical fittings Gas exhaust port Inspiratory channel Male 22 mm female 15 mm In accordance with ISO 5356 1 Male 30 mm cone Pressure drop Internal compressible factor Gas delivery system Inspiratory flow range Max 6 cm at a flow of 1 1 s Max 0 1 Microprocessor controlled valves 0 to 3 3 l s Expiratory channel Pressure drop Internal compressible factor PEEP regulation Expiratory flow range Rise time expiratory flow measurement Max 3 at a flow of 1 1 s 0 1 Microprocessor controlled valves 0 to 3 2 l s 12 ms for 10 90 96 response at a flow of 0 05 3 2 l s Critical Care SERVO s 9 Airway pressure upper Invasive ventilation Non Invasive Ventilation High continuous pressure con
2. A Previous Mode functionality allows for easy switching back to the previous ventilation mode with its latest set tings The Alarm output connection option provides connec tivity to an external alarm system The monitoring capabilities of SERVO s ensure more accurate time and detail recording through trend alterna tives Information can be retrieved for further analysis up to 24 hours after an event SERVO s is now available with a non consumable and maintenance free O sensor as an option to the consum able cell which needs replacement about once a year The new sensor is based on ultrasonic technology Existing SERVO s ventilators can easily be upgraded Built in rechargeable batteries provide a 60 minute backup in case of mains power failure Total battery ca pacity is shown in time on the display for added safety Aeroneb Pro is a stand alone nebulizer system based on vibration technology It is small and lightweight and can easily be connected to the SERVO s Critical Care SERVO s 7 SERVO s is designed for easy cleaning and mainte nance With a one piece interchangeable expiratory cas sette you can instantly make the system ready for the next patient For added flexibility in hospitals with no central air sup ply the Compressor Mini has been designed to supply the ventilator with dry filtered compressed air The quiet compact design makes it particularly suitable for bedside use 8
3. ATIONS SERVO s Controlled ventilation Stored trend Volume Control VC Volume controlled ventilation eg Pressure Control PC Pressure controlled ventilation Breathing frequency Yes Yes Sl M Spontaneous breaths per minute Yes Yes Pressure Support PS Pressure supported ventilation 4 Continuous Positive Airway Pressure RESP EE Peak Airway Pressure Yes Yes aio Mean Airway Pressure Yes Yes Combined ventilation Pause Airway Pressure Yes Yes SIMV VC PS Synchronized Intermittent Mandatory End Expiratory Pressure Yes Yes Ventilation based on volume controlled End Expiratory Flow Yes Yes ventilation with pressure support Inspired Tidal Volume Yes Yes SIMV PC PS Synchronized Intermittent Mandatory Expired Tidal Volume Yes Yes Ventilation based on pressure controlled Inspired Minute Volume Yes Yes ventilation with pressure support Expired Minute Volume Yes Yes Ti Ttot Yes No Ventilation Modes Non Invasive Ventilation optional E Ratio Yes No NIV Pressure Control invasive pressure controlled Measured Concentration Yes Yes ventilation Spontaneous Exp Minute Volume No Yes NIV Pressure Support Non invasive pressure supported MV sp ventilation Leakage fraction in NIV 96 Yes Yes Supply pressure O and air Yes No Battery remaining time Yes No Loops Volume Pressure Barometric pressure Yes No Flow Volume Real time wavef
4. MAQUET VENTILATION SERVO s CRITICAL The Gold Standard Critical Care SERVO s 3 SERVO s PROVEN SERVO SIMPLICITY RELIABILITY AND SENSITIVITY MAQUET THE GOLD STANDARD Leading the way MAQUET is a premier international MAQUET SERVO ventilators set the standard for the field provider of medical products for intensive care and op of critical care Based on proven SERVO technology erating rooms A firm commitment to investment in re SERVO s offers state of the art mechanical ventilation in search and development ensures that MAQUET products straightforward package It is reliable sensitive to patient continue to make significant contributions to improving effort and easy to use SERVO s delivers top performance patient care for both pediatric and adult patients in a variety of hospital ventilatory care settings SERVO s proudly takes its place in the SERVO ventilator family SERVO s Proven Servo simplicity reliability and sensi tivity MAQUET The Gold Standard 4 SERVO s Critical Care HIGHLIGHTS SERVO s For adult and pediatric patients 2 A ventilator system designed to operate in a variety of hospital ventilatory care settings Ventilation modes Controlled ventilation Volume Control VC Pressure Control PC Supported ventilation Pressure Support PS CPAP Combined ventilation SIMV VO PS SIMV PC PS Options Alarm output conne
5. SERVO s Critical Care TECHNICAL SPECIFICATIONS SERVO s C The device complies with requirements of Power supply automatic 100 120 V AC 1096 50 60 Hz or 0413 Medical Device Directive 93 42 EEC range selection 220 240 V AC 1096 50 60 Hz Classification Class equipment According to External 12 V DC 12 0 to 15 0 V DC 10A IEC 60 601 1 EN 60 601 1 Battery capacity Rechargable 12 V 7 Ah Standards EN IEC 60 601 1 Class Type B Battery backup time Approximately 1 h EN IEC 60 601 2 12 Battery recharge time Approximately 6 h EN 794 1 Max power consumption At 100 120 V 2 A 190 VA 140 W Electromagnetic At 220 240 V 1 A 190 VA 140 W compatibility EMC Emission According to EN IEC 60601 1 2 Edition 2 Immunity According to EN IEC 60601 1 2 Edition 2 Dimensions See dimensional drawings page 13 14 Patient range Tidal volume 100 to 2000 ml patient User Interface and W 380 x D 300 x H 520 mm weight approximately 10 to 250 kg Patient Unit User Interface W 355 x D 53 x H 295 mm Patient Unit W 380 x D 300 x H 210 mm Operating temperature 10 to 40 C Weight Approximately 18 kg Relative humidity 15 to 95 non condensing Method of triggering Flow and pressure Atmospheric pressure 660 to 1060 hPa Max operating pressure Approximately 115 cm H O Lowest pressure in 400 cm Bias flow 2 l min breathing system Type TFT LCD module Impact Peak acceleration 15 g Size
6. ath In SIMV mode initiation of 1 mandatory breath Insp or exp 0 30 seconds 2 minute silence and reset of latched alarms On Off Critical Care SERVO s 11 Pre oxygenation time Max 2 min Post oxygenation time Max 1 min Suction phase time No maximum level Adjustable oxygen level 21 100 96 Communication Interface Serial port RS 232C isolated For data communication via the Communication Interface Emulator CIE MIB Medical Information Bus monitor connection Network connection optional Non Invasive Ventilation NIV optional Ventilation modes Pressure Support Pressure Control Max leakage 50 l min compensation level Leakage overrange Automatic detection Disconnect detection Automatic Manual or automatic via bias flow Manually adjustable breathing rate The breathing rate is controlled by the ventilator in the event of apnea Connect detection Backup rate in NIV Pressure Support Alarm output connector optional Connector 4 pole Modular connector Ratings Max 40 V DC Max 500 mA Max 20 W Regular maintenance Once every 12 months or at least after 5000 hours of operation For inaccuracies and more detailed technical specifications please refer to the User s manual 12 SERVO s Critical Care TECHNICAL SPECIFICATIONS SERVO s ACCESSORIES Shelf base SERVO s optional Weight 0 1 kg Aeroneb Pro Nebulizer System optional a l camm x
7. cal Care SERVO s 5 GENERAL INFORMATION SERVO s The SERVO s ventilator is based on proven SERVO technology ensuring safe reliable and high quality ventila tion By combining state of the art sensitivity and reliabil ity with simplicity SERVO s ensures top performance for both adult and pediatric patients in a variety of hospital ventilatory care treatment facilities SERVO cs features a range of user interface tools which allow the ventilator to be tailored to the clinical situation Ease of training operation and maintenance are key SERVO cs features The SERVO Feedback Control System in SERVO s im mediately responds to patient needs in terms of pres sure and flow changes Even the smallest deviations from set values are sensed fed back to the SERVO controlled valves and regulated several hundred times a second Thus the SERVO Feedback control system gives the pa tient exactly the ventilation you have chosen This improves lung protection patient SERVO s can positioned on the Mobile Cart for greater flexibility and promotes spontaneous breathing by providing timely as mobility sistance thus reducing the work of breathing and im proving patient comfort The results are improved care quality and cost effective operation The intuitive graphical user interface of the SERVO s facilitates control and rapid system response Direct ac cess knobs ensure fast changes of vital settings when nee
8. centration Expired minute volume Upper alarm limit Expired minute volume Lower alarm limit Gas supply Apnea Respiratory frequency Battery High end expiratory pressure Low end expiratory pressure Leakage out of range in NIV No patient effort in NIV Technical Autoset alarm limits specification High airway pressure Upper minute volume Lower minute volume Upper respiratory frequency Lower respiratory frequency High end expiratory pressure Low end expiratory pressure 16 120 cm 16 60 cm H O Set PEEP level 15 cm H O exceeded for more than 15 seconds Set value 6 vol or 18 vol 0 5 60 l min 0 5 40 l min Below 200 kPa 2 0 bar 29 PSI and above 650 kPa 6 5 bar 94 PSI 15 45s 1 160 breaths min Limited battery capacity 10 min No battery capacity less than 3 min Low battery voltage 0 55 cm H O 0 47 H O Note Setting the alarm to 0 zero is equal to alarm off Yes Described in the User s manual 45 Yes Described in the User s manual Invasive ventilation controlled modes only Mean peak pressure 10 cm or at least 35 cm H20 Expiratory minute volume 50 Expiratory minute volume 50 Breathing frequency 40 Breathing frequency 40 Mean end expiratory pressure 5 H20 Mean end expiratory pressure cm H O 10 SERVO s Critical Care TECHNICAL SPECIFIC
9. ction for external alarm Non Invasive Ventilation NIV Pressure Support Pressure Control Supports invasive ventilation as well as Non Invasive Ventilation NIV with leakage compensation 2 High level of sensitivity to your patients efforts Precise gas delivery system Extreme speed in sensing and regulation Simple to learn Self intuitive user interface Simple to operate Large color display with clear graphic presentation Selectable between touch screen direct access knobs or dial Fast simple start up procedure e g automated pre use check with user configured pre set ventilator settings Suction Support Previous Mode functionality High resolution flow pressure and volume waveforms 2 Simple to maintain clean One piece interchangeable part for cleaning Extended maintenance interval 5000 hours Maintenance information given via graphical user interface Reliable Battery back up 60 minutes Apnea back up Direct access knobs for vital settings Enhanced alarm system 2 Uninterrupted bedside quality ventilatory treatment during in hospital transportation with Mobile Cart Possibility for shelf mounting Diagnostic trend tools ensure accurate time and detail recording for up to 24 hours after an event Volume Pressure and Flow Volume loops Non consumable and maintenance free ultrasonic sensor optional to consumable O cell Criti
10. ded Staff will be able to make the right decisions and choose the right settings even in stressful moments SERVO s can also be secured on a shelf using the shelf base for attachment 6 SERVO s Critical Care GENERAL INFORMATION SERVO s SERVO s supports both invasive ventilation and Non Invasive Ventilation NIV SERVO s supports invasive ventilation and also Non In vasive Ventilation NIV with an effective leakage compen sation thus maintaining the pressure set to the patient NIV supports ventilation in the Pressure Control and Pres sure Support modes In the case of apnea a ventilator controlled breathing frequency is automatically activated to maintain desired ventilation Four different ventilation modes let you tailor patient treatment to individual needs Volume Control VC Instead of delivering only a set flow as in a traditional volume control mode which may work against the patient s own effort SERVO s senses the patient s demand for higher flow during inspiration This will ensure improved patient interaction by delivering set tidal volume as a minimum or a higher tidal volume if demanded by the patient Pressure Control PC Thanks to the SERVO feedback control system which constantly reacts to deviations in pressure the SERVO s Pressure Control mode ensures that a constant pressure is maintained through the inspi ration time and thereby secures an even gas distribution Press
11. in healthcare and life science and MAQUET for Surgical Workplaces Cardiopulmonary and Critical Care O Maquet Critical Care AB 2006 All rights reserved MAQUET reserves the right to modify the design and specifications contained herein without prior notice Order No 66 70 115 SERVO s System Version 3 1 Data Sheet Printed in Sweden 0306 3 Rev 03 English Price Group 10 NOT FOR DISTRIBUTION IN USA
12. orms Pressure waveform Flow waveform Event log Alarms Volume waveform Ventilator settings Apnea periods Immediate functions Service log Technical alarms Test results Preventive maintenance Service report history Configuration log TECHNICAL SPECIFICATIONS SERVO s Parameter settings Parameter Inspiratory tidal volume ml Inspiratory minute volume l min Apnea time till alarm s Pressure level cm H20 PEEP cm H20 PEEP in NIV H20 CMV frequency breaths min SIMV frequency breaths min Breath cycle time SIMV s PS above PEEP cm 0 PS above PEEP in NIV cm H20 Back up pressure above PEEP H20 NIV Back up rate breaths min concentration 96 Tinsp s NIV Back up Tinsp S E Ratio of breath cycle time Flow trigger sensitivity level fraction of bias flow Press trigg sensitivity cm H20 Insp rise time 96 of breath cycle time Insp rise time 5 Insp cycle off 96 of peak flow Insp cycle off in NIV 96 of peak flow Oxygen breaths Start breath Pause hold Alarm silence reset Compliance compensation Setting range 100 2000 0 5 60 15 45 0 120 PEEP 0 50 2 20 4 100 1 60 1 15 0 120 PEEP 0 32 PEEP 5 120 4 20 21 100 0 1 5 0 5 2 1 10 4 1 0 30 0 10096 20 0 0 20 0 0 4 1 70 10 70 100 for 1 minute Initiation of 1 bre
13. ure Support Continuous Positive Airway Pres sure PS CPAP Easy triggering and fast response to changing patient demand is important in assisted breath ing When ventilating a patient in Pressure Support mode with SERVO s customization to every patient s needs can easily be achieved by adjusting inspiratory rise time and cycle off criteria thus optimizing flow adaptation to patient effort work of breathing and patient comfort A back up apnea function ensures safe invasive ventila tion in the Pressure Support mode Synchronized Intermittent Mandatory Ventilation SIMV In this combination mode the ventilator will de liver controlled mandatory breaths These are synchro nized with the breathing efforts of the patient The patient can breathe spontaneously in between the mandatory breaths SIMV ensures that patient triggered breaths are always supported GENERAL INFORMATION SERVO s The automated pre use check which only takes a few minutes offers a fast and simple start up procedure with an optimal calibration before connecting to a patient The user can configure the ventilator to start up exactly the way he wants The default ventilation mode as well as all the corresponding default ventilation parameters can be set by the user The Suction Support function pauses the ventilator from cycling during a tracheal suction procedure The ox ygen concentration can be manually set during pre and post oxygenation phases
14. w omm See separate data sheet see dimensional drawing below Mobile Cart SERVO s optional ER restrainer EPI pem Weight 25 kg ax load x 5 liter bottles Dimensions H 830 mm with handles 1 040 mm X 1 650 mm x W 500 mm Compressor Mini optional see dimensional drawing below pee Sep siete data siest Critical Care SERVO s 13 TECHNICAL SPECIFICATIONS SERVO s DIMENSIONAL DRAWINGS SERVO s on Mobile Cart 83 cm SERVO s on Shelf base 35 5 cm 14 SERVO s Critical Care TECHNICAL SPECIFICATIONS SERVO s Mobile Cart SERVO s 83 cm 50 cm 65 cm I 104 cm Shelf Base SERVO s 0 8 cm 6 16 Critical SERVO s 15 ORDERING INFORMATION SERVO s SERVO s Ventilator and accessories See separate information SERVO s System Version 3 1 System Flow Chart Order no 66 70 112 MAQUET Maquet Critical Care AB SE 171 95 Solna Sweden Phone 46 0 8 730 73 00 www maquet com For local contact Please visit our website www maquet com GETINGE GETINGE Group is a leading global provider of equipment and systems that contributes to quality enhancement and cost efficiency within healthcare and life sciences Equipment services and tech nologies are supplied under the brands ARJO for patient hygiene patient handling and wound care GETINGE for infection control and prevention with