1. Liferiver Revision No ZJO006 Issue Date Jul 1 2012 HIV 2 Real Time RT PCR Kit User Manual For In Vitro Diagnostic Use Only 20 C SR 0021 02 25 For use with ABI Prism 7000 7300 7500 7900 Step One Plus iCycler iQ 4 iQ 5 Smart Cycler Il Bio Rad CFX 96 Rotor Gene 6000 Mx3000P 3005P MJ Option2 Chromo4 LightCycler 480 Instrument ual Shanghai ZJ Bio Tech Co Ltd www liferiver com cn Tel 86 21 34680596 trade liferiver com cn Fax 86 21 34680595 2 floor No 15 Building No 188 Xinjunhuan road PuJiang Hi tech Park Shanghai China 1 Intended Use HIV 2 real time RT PCR kit is used for the detection of HIV 2 in serum by using real time PCR systems 2 Principle of Real Time PCR The principle of the real time detection is based on the fluorogenic 5 nuclease assay During the PCR reaction the DNA polymerase cleaves the probe at the 5 end and separates the reporter dye from the quencher dye only when the probe hybridizes to the target DNA This cleavage results in the fluorescent signal generated by the cleaved reporter dye which is monitored real time by the PCR detection system The PCR cycle at which an increase in the fluorescence signal is detected initially Ct is proportional to the amount of the specific PCR product Monitoring the fluorescence intensities during Real Time allows the detection of the accumulating product without having to re open the reaction tube after the amplification 3
2. 5 If you use ABI Prism system please choose none as passive reference and quencher 10 Threshold setting just above the maximum level of molecular grade water 11 Calibration for quantitative detection Input each concentration of standard controls at the end of run and a standard curve will be automatically formed 12 Quality control Negative control positive control internal control and QS curve must be performed correctly otherwise the sample results is invalid Ct value Oo y ive S O Positive Conrolqualiatveasayy 35 o 13 Data Analysis and Interpretation The following sample results are possible Ct value Result Anal UNDET 25 35 Below the detection limit or negative 2 lt 38 o Positive and the software displays the quantitative value 38 40 25 35 Re test If it is still 38 40 report as 1 UNDET UNDET PCR Inhibition No diagnosis can be concluded For further questions or problems please contact our technical support at trade liferiver com cn
3. Product Description Human immunodeficiency virus HIV is a retrovirus that can lead to acquired immunodeficiency syndrome AIDS Infection with HIV occurs by the transfer of blood semen vaginal fluid pre ejaculate or breast milk HIV infection in humans is now pandemic Two species of HIV infect humans HIV 1 and HIV 2 HIV 1 is more virulent It is easily transmitted and is the cause of the majority of HIV infections globally HIV 2 is less transmittable and is largely confined to West Africa HIV 2 real time RT PCR kit contains a specific ready to use system for HIV 2 detection through Reverse Transcription Polymerase Chain Reaction RT PCR in the real time PCR system The master contains Super Mix for the specific amplification of HIV 2 RNA including subtype A G The reaction is done in one step real time RT PCR The first step is a reverse transcription RT during which the HIV 2 RNA is transcribed into cDNA Then a thermostable DNA polymerase is used to amplify the specific gene fragments by polymerase chain reaction PCR Fluorescence is emitted and measured by the real time systems optical unit during the PCR The detection of amplified HIV 2 DNA fragment is performed in fluorimeter channel FAM with the fluorescent quencher BHQI1 In addition the kit can be used for identification of possible PCR inhibition by measuring the HEX VICH OE fluorescence of the internal control IC An external positive control defined as 1x10 IU ml is su
4. R system e Real time PCR reaction tubes plates e Pipets 0 5u1 1000u1 e Sterile microtubes Ts AS Warnings and Precaution Carefully read this instruction before starting the procedure e For in vitro diagnostic use only e This assay needs to be carried out by skilled personnel e Clinical samples should be regarded as potentially infectious materials and should be prepared in a laminar flow hood e This assay needs to be run according to Good Laboratory Practice e Do not use the kit after its expiration date e Avoid repeated thawing and freezing of the reagents this may reduce the sensitivity of the test e Once the reagents have been thawed vortex and centrifuge briefly the tubes before use e Prepare quickly the Reaction mix on ice or in the cooling block e Set up two separate working areas 1 isolation of the RNA DNA and 2 amplification detection of amplification products e Pipets vials and other working materials should not circulate among working units e Use always sterile pipette tips with filters e Wear separate coats and gloves in each area e Avoid aerosols 8 Sample Collection Storage and transport e Collected samples in sterile tubes e Specimens can be extracted immediately or frozen at 20 C to 80 C e Transportation of clinical specimens must comply with local regulations for the transport of etiologic agents 9 Procedure 9 1 RNA Extraction Different brand RNA Extraction kits are available You may use you
5. ix thoroughly before next transfer B The positive control 1x10 IU ml contains high concentration of the target DNA Therefore be careful during the dilution in order to avoid contamination 9 4 RT PCR Protocol The Master Mix volume for each reaction should be pipetted as follows 18ul 1 yl 1yl Super Mix Enzyme Mix Internal Control Sul 20 Extraction RNA Master Mix Reaction Plate Tube PCR Instrument XPCR system without HEX VIC JOE channel may be treated with 11 Molecular Grade Water instead of 11 IC 1 The volumes of Super Mix and Enzyme Mix per reaction multiply with the number of samples which includes the number of controls standards and sample prepared Molecular Grade Water is used as the negative control For reasons of unprecise pipetting always add an extra virtual sample Mix completely then spin down briefly in a centrifuge 2 Pipet 20ul Master Mix with micropipets of sterile filter tips to each of the Real time PCR reaction plate tubes Separately add 5ul RNA sample positive and negative controls to different reaction plate tubes Immediately close the plate tubes to avoid contamination 3 Spin down briefly in order to collect the Master Mix in the bottom of the reaction tubes 4 Perform the following protocol in the instrument 45 C for 10min Selection of fluorescence channels 95 C for 15min Target Nucleic Acid 95 C for 15sec 60 C for Imin HEX VIC JOE AOcycles Fluorescence measured at 60 C
6. pplied It allows the determination of the gene load For further information please refer to section 9 3 Quantitation 4 Kit Contents HIV 2 Super Mix RT PCR Enzyme Mix 1 vial 480u1 1 vial 28ul Molecular Grade Water 1 vial 400u1 Internal Control IC 1 vial 30u1 HIV 2 Positive Control 1x10 IU ml 1 vial 30ul Analysis sensitivity 5X 10 TU ml LOQ 1X 10 1X 10 IU ml Note Analysis sensitivity depends on the sample volume elution volume nucleic acid extraction methods and other factors If you use the DNA extraction buffer in the kit the analysis sensitivity is the same as it declares However when the sample volume is dozens or even hundreds of times greater than elution volume by some concentrating method it can be much higher 5 Storage e All reagents should be stored at 20 C Storage at 4 C is not recommended e All reagents can be used until the expiration date indicated on the kit label e Repeated thawing and freezing gt 3x should be avoided as this may reduce the sensitivity of the assay e Cool all reagents during the working steps e Super Mix should be stored in the dark 6 Additionally Required Materials and Devices e Biological cabinet e Vortex mixer e Cryo container e Sterile filter tips for micro pipets e Disposable gloves powderless e Biohazard waste container e Refrigerator and Freezer e Tube racks e Desktop microcentrifuge for eppendorf type tubes RCF max 16 000 x g e Real time PC
7. r own extraction systems or the commercial kit based on the yield For the RNA extraction please comply with the manufacturer s instructions The recommended extraction kit is as follows Nucleic Acid Isolation Kit Cat Number RNA Isolation Kit ME 0010 ME 0012 ZJ Biotech QIAamp Viral RNA Mini extraction Kit 50 52904 QIAGEN 9 2 Internal Control It is necessary to add internal control IC in the reaction mix Internal Control IC allows the user to determine and control the possibility of PCR inhibition Add the internal control IC 1ul rxn and the result will be shown in the HEX VIC JOE 9 3 Quantitation The kit can be used for quantitative or qualitative real time RT PCR A positive control defined as 1x10 IU ml is supplied in the kit For performance of quantitative real time PCR standard dilutions must be prepared first as follows Molecular Grade Water is used for dilution The step of dilution is not needed for performance of qualitative real time PCR Take positive control 1x10 IU ml as the starting high standard in the first tube Respectively pipette 36ul of Molecular Grade Water into next three tubes Do three dilutions as the following figures Dilution of Standards 4ul dul 4ul VY V V Y 1X107 1X10 1X10 1X104 IUjmi To generate a standard curve on the real time system all four dilution standards should be used and defined as standard with specification of the corresponding concentrations Attention A M

Download Pdf Manuals

image

Related Search

Related Contents

Compaq Switch 6 Switch User Manual  The Beginner`s Domain Name and Cash Parking Guide  Avaya 1000 Series Video Conferencing Systems Application Note  Kenmore 625.38356 User's Manual  BUW-0255-12 LaserMeter50 Web FR.indd  Fog Machine Instructions  WARNER BROS. PICTURES Présente  L`appareil de commande IRG 2-N    Bedienungsanleitung  