Contents
1. inserts nennen 13 5 2 Cleaning the fan grille i EN 13 5 3 External Cl SUMING r A 13 5 4 EEn 14 oe Strade and St SID DING mutsaers 14 5 6 Recall EAI eenen ae ent eenden 14 6 Product Specifications cccceeeee cece cece eee cere ener eee e eee e eens eee e seen eee e eee eeeeeees 15 6 1 Sa pe E A EAA nerven 15 6 2 Generation and Control nana nende tehebben 15 6 3 Option and AccesSsorieS s sssssssrssrsrrnrrrrnrrrrnrrnrerenrrrrnnrrrnrrrrnnrnrerenne 15 TRAQC 3 LH 07 2014 EN Rev 1 page 2 s Tradinco De User Manual TRAQC 3 LH 1 General 1 1 Warranty During the design and manufacturing of this instrument the at most attention has been given to quality and durability This manual contains information needed for the safe and effective use of the capabilities of the instrument Please read the manual carefully before operating the instrument By doing so possible damage to the instrument or damage caused by the incorrect use of the instrument can be avoided TRADINCO INSTRUMENTS warrantees the instrument in accordance with the Standard Terms and Conditions of the Instrument Trade as issued by the Association bearing the name Federation Het Instrument The Instrument Federation filed with the Clerk of Utrecht District Court on 13 January 1993 under number 16 93 and with the Chamber of Commerce and Industry in Amersfoort on 18 January 1993 A copy is available on request TRADINCO INSTRUMENTS war
2. 1 page 4 s Tradinco De User Manual TRAQC 3 LH 1 5 CE Electrical Safety Directive 73 23 CE The electrical part of the TRAQC 3 LH meets the regulations according to the standard listed below e EN 61010 1 1995 The unit is CE marked accordingly 1 6 Symbols Used Warning for conditions or practices that could result in personal injury loss of life and or in damage to the product or other property iS Attention signal or remark AN Danger of electrical shock 1 7 Scope of this manual This manual contains information for instruments built after January 2014 This manual is a user manual on how to operate the instrument it is not a calibration instruction manual As Tradinco Instruments continuously strives to improve its products specifications of instruments may be altered without further notice 1 8 Instrument Label inco SS Tradinco g Instruments n Company Type No TRAQC 3LH Serial No XXXX X Range ambiant 5 C to 650 C Power 230 Vac 50 60Hz 2000 W Fuse 2x 10A 250 VAC Date XXX Berkel en Rodenrijs The Netherlands E Mail info tradinco com TRAQC 3 LH 07 2014 EN Rev 1 page 5 Se Tradinco EE nn User Manual TRAQC 3 LH 2 Important Knowledge The factors which characterize a dry block oven are Accuracy of the display compared to a standard The stability over time The axial homogeneity of the block The boring to boring homogeneity T
3. Remove the insert from the heat block well at regular intervals e Clean heat block well with a dry cloth If the heat block well is very polluted it can be cleaned with a brass tube wire brush After cleaning flush the heat block well with compressed air e Clean the bore and outside of the insert with a dry cloth If the bore of the heat insert is very polluted it can be cleaned with a brass tube wire brush The outside with a brass wire brush After cleaning flush the bore of the insert with compressed air and clean the outside with a dry cloth If the TRAQC 3 LH is not operated for longer periods or moved remove the insert from the heat block and store the insert in one of the two insert storing holes 5 2 Cleaning the fan grille On the bottom the TRAQC 3 LH is fitted with an air grille via which cooling air enters the TRAQC 3 LH Clean the grille at regular intervals vacuuming or brushing depending on the level of air pollution 5 3 External cleaning Clean the outside of the TRAQC 3 LH with a damp cloth and some water or with a solvent free and mild cleaning agent TRAQC 3 LH 07 2014 EN Rev 1 page 13 er Tradinco lt s PER E anena User Manual TRAQC 3 LH 5 4 Fuse With a flat screwdriver max 2 5mm press down both snap fittings of the fuse drawer Take out the fuse drawer and replace both fuses Two Fuses 2x 10A antisurge 250VAC must be used 5 5 Sto
4. TRAQC 3 LH Dry block Calibrator User Manual s Tradinco PE osne User Manual TRAQC 3 LH Content 1 E Al E T E ES E PEES T E A E A E ER 3 1 1 W AA E O OEE 3 132 TRAOC 3 LA DESCIIPUON ccs2casccercsccseescancnceseinsatescsadieetetetasaneaasecssinta nes 4 1 3 Standard EqUiDMENE samira iain 4 1 4 CE EMC Directive 89 336 EEC neen eenen nnen 4 1 5 CE Electrical Safety Directive 73 23 CE oane venen nnnennn 5 1 6 SYNPO WISE irri A a a meeten beet 5 1 7 Scope of this manual nennen nennen nennen nennen 5 1 8 Insirument EBS mwn tn nt 5 De Important KNOW ECGS ar nnn meae 6 2 1 Accuracy of the display compared to a standard een 6 22 SEAN on E T E A EA A E E A A E A 6 2 3 TAE axial MONOGENSIEN ror ensen antenne 6 2 4 The boring to boring homogeneity nennen nnee 6 Gi Functions and connections ss ssssssessssenssronesnrnrnnsnennsnronenrnnennenennrnenrne 7 3 1 FFON veuccpunesraetenogsecauaegradureadenemeeeuehaagenetaeuwele aed otranerceuvaadeneseamaral 7 3 2 POD wneer ee vennen ever werende on Ruwe neen cen Ede En 8 3 3 BEK E E dert atteednee nternet errata 9 4 operaung TASCFUCHONS nsevecasatavecscccevcquucssvese inde vans acuveneeneevenevecayecveceventes 10 4 1 TRA OCA S a E A eenden 10 4 2 Temperature switch ssssssssssssnssssnesnnnssnnnsnnsnrnnsnrnnsnrenenrnnseunnnesnnnne 12 4 3 End OF USS eneen ee A EA 12 5 MAES RAN CS enten ee Tr ee ee er 13 Bad Cleaning TRAQC 3 LH heat block and
5. Watt Internal sensor break detection Fuse 2x 10A antisurge 250 VAC Thermal Protection switch 140 C Safety NEN EN IEC 61010 1 Conformity EMC NEN EN IEC 61000 4 3 3 2 3 3 4 2 4 4 4 5 Well depth Max 175mm recommended 95mm Well diameter Max 26mm Weight 11 5 KG without power cord incl insert Dimensions LxWxH 6 2 Generation and control 50 C to 650 C 0 5 C up to 500 C 1 C up to 650 C 0 04 C Temperature range Accuracy Stability Worst case boring to boring difference Stabilization 399 3x149 3x298mm 399 3x143 3x346mm including insulation tube 0 3 C 3 borings in insert 35 minutes Axial temperature Homogeneity 40 mm at 95 mm well depth 0 45 C at 500 C and 0 8 C at 650 C and in accordance with Euramet CG 13 Heating time ambient to 650 C 30 minutes Cooling time 650 C to 100 C 65 minutes All specifications ambient temperature 20 C 42 C 6 3 Option and Accessories e RvA accredited calibration certificate for temperature traceable to international standards AutoCal calibration management software Cleaning set brass wire brush and brass tube wire brush Insert 1 2 3 or 4 bore s or undrilled Sizes upon request Carrying case Carrying case Rugged A rugged carrying case which offers maximum protection during transport This case is watertight and is secured by two safety latches It stores the TRAQC 3 LH up to 3 inserts ins
6. X see above e Place the correct insert for the unit under test into the heat block well To ensure a good calibration the probe diameter has to be 0 2mm smaller than oS the diameter of the bore in the insert TRAQC 3 LH 07 2014 EN Rev 1 page 10 Se Tradinco lt Den User Manual TRAQC 3 LH Never handle very hot inserts The insert should cool down to less than 200 C before being placed in one of the insert storage holes Always use the insert grabber e Place the insulation tube onto the insert Never handle the insulation tube when it s hot The insulation tube should cool AN down to less than 200 C before being placed in insulation storage hole Always use the insert grabber IS Always place the insulation tube The passing air can seriously affect the calibration due to the passing air of the cooling fan onto the to be calibrated probe e Place unit under test RTD thermo couple temp switch etc in the insert bore IS It is recommended to use the centre hole for all measurements At special request from customers the pattern of insert holes may differ a temperature reference hole may be ordered as a extra option See also section 2 4 for proper use of the borings in the insert e With the up and down pushbuttons the desired temperature can be set between 50 C and 650 C AN Make sure the upper grill is not blocked e Set the first calibration test p
7. at what position in the probe or UUT the PT100 or Thermocouple is placed The Euromet CG 13 Guideline mentions a 4 cm homogenise zone as a kind of a norm 2 4 The boring to boring homogeneity Most dry well block calibrators have an insert with more than one boring If there is one boring this boring is usually in the centre An ideal symmetric situation with internal heaters elements is then automatically provided With two borings a symmetrical position of both borings can be reached if the position is of each boring is at equal distance to the heating element A mark of the insert should then be provided This mark should be placed in line with the mark on the block Again this is often overlooked but an important factor in determining the uncertainty of a calibration Once one is aware of this issue one can easily take appropriate counter measures TRAQC 3 LH 07 2014 EN Rev 1 page 6 Instruments Use Mal iual RAQC 3 LH TRA Chlibrati i CORP t y 3 Functions and connections 3 1 Front 1 Display 2 Pushbutton used for factory settings 3 Switching indicator Led 4 Up and down pushbuttons 5 Temperature switch 4mm sockets TRAQC 3 LH 07 2014 EN Rev 1 page 7 ns Tradinco g o aiken User Manual TRAQC 3 LH 3 2 Top 2 3 3 4 1 5 6 7 1 Insert grabber 2 Insulation tube storage hole 3 Insert storage holes 4 Carrying handle 5 Opening and closing louver 6 Heat block well 7 Upper gril
8. ements e The instrument is electronically controlled and regulated with 2 push buttons on the front panel and indicates the temperature in the display in the front panel e The temperature is controlled by a precision platinum resistance thermometer RTD sensor and an intelligent closed loop circuit e The heating block warming and cooling time is optimised with a large cooling fan and an automated shut opening and closing louver to further optimise the heating performance e RS232 communication interface e RS232 cable The aluminum housing is equipped with a carrying handle Up to two inserts insert puller and insulating tube can be stored inside the TRAQC 3 LH calibrator Dimensions are LxWxH 399 3x149 3x298mm 399 3x143 3x333mm including insulation tube and the weight is approximately 11 5 kg 1 3 Standard Equipment The TRAQC 3 LH will be standard equipped with the following TRAQC LH dry block calibrator Instruction manual on cd Traceable calibration report Insert 6 2mm bore Mains power cord e RS232 cable More equipment is optional see other accessories chapter 6 3 1 4 CE EMC Directive 89 336 EEC The electrical part of the TRAQC 3 LH meets the regulations according to the standards listed below e EN IEC 61000 4 2 2009 e EN IEC 61000 4 3 2009 e EN IEC 61000 4 4 2009 e EN IEC 61000 4 5 2009 e EN IEC 61000 3 2 2009 e EN IEC 61000 3 3 2009 The unit is CE marked accordingly TRAQC 3 LH 07 2014 EN Rev
9. ert grabber mains power cord cleaning set manual and calibration certificate TRAQC 3 LH 07 2014 EN Rev 1 page 15 sz Tradinco sZ Eene User Manual TRAQC 3 LH TRADINCO INSTRUMENTS Industrieweg 74 Postbus 37 2650 AA Berkel en Rodenrijs The Netherlands 31 0 10 5112911 www tradinco com info tradinco com TRAQC 3 LH 07 2014 EN Rev 1 page 16 sy Tradinco ee The Oe User Manual TRAQC 3 LH TRAQC 3 LH 07 2014 EN Rev 1 page 17
10. he European Association of National Metrology Institutes Euromet CG 13 Guideline describes this in detail This paragraph will briefly discuss the parameters above Please note that the importance and pit falls with these parameters are often overlooked More important is to specify these parameters correctly in order to know the measurement uncertainty 2 1 Accuracy of the display compared to a standard Usually a dry well block oven is used in combination with a standard temperature measuring instrument A Unit under test UUT is in that instance calibrated against the said standard Important then is to have a dry well which can hold its temperature very Stable 2 2 Stability Is defined as temperature variation as function of time The Euromet CG 13 guideline uses a 30 minute interval This makes clear that a good stability over a long period of time is actually a good stability 2 3 The axial homogeneity Is probably the most important and forgotten parameter of a dry well block calibrator If one uses a probe with 5 mm length and measure at intervals the temperature while pulling out this probe one can determine the axial gradient Due to its geometry isolation characteristics the heat loss of the probe etc the heating bloc is not homogenise in temperature Differences in the order of magnitude of degrees of Celsius are often found This parameter is very important because usually it is not known how long a PT 100 in a probe is or
11. l TRAQC 3 LH 07 2014 EN Rev 1 page 8 EZ Tradinco lt o Nn User Manual TRAQC 3 LH 3 3 Back KRW N 1 9 Pin RS232 port 2 ON OFF Switch 3 Fuse drawer 4 Mains power cord connector 5 Carrying handle TRAQC 3 LH 07 2014 EN Rev 1 page 9 Se Tradinco lt PEO wanena User Manual TRAQC 3 LH 4 Operating instructions 4 1 TRAQC 3 LH Note Please observe proper grounding of the instrument Use the supplied power AN cord if possible upper grill becomes very hot Also the air above the instrument heats up When operating be careful not to burn yourself and that the heated air can freely flow into the room without damaging interfering anything Be careful the top parts around the heat block of the TRAQC 3 LH especially the e Place instrument in a way that the ventilation openings on the underside and side panels of the instrument are not obstructed for proper measurement results e Connect the power cord to the unit and turn it on IS When the TRAQC 3 LH starts up a sequence of different numbers will be shown in the display 8888 check all segments of the display Prog then a number this shows the software revision number XXXX a code number for manufacturers use only XX a code number for manufacturers use only Hr XX The amount of hours the TRAQC 3 LH has been powered the six digits after the Hr represent the hours up to 99999 9 hrs XX
12. oint e After 1 second the display indicates the actual temperature e After the unit has reached its set point the specified accuracy is reached after 5 till 10 minutes e Observe at least 35 minutes stabilisation time when the set temperature is reached in order to achieve the specified stabilization accuracy TRAQC 3 LH 07 2014 EN Rev 1 page 11 ALT Se Tradinco lt Eenden User Manual TRAQC 3 LH While heating a led O1 or A1 in the left upper corner of the display will flash Flashing will be intermittent and regular as the unit reaches the set temperature e Follow steps 5 thru 8 for every calibration point e For decreasing the temperature the same procedure as described above must be followed To provide provide an optimum use of the TRAQC 3 LH all control functions are iy available through a RS232 interface With the Tradinco AutoCal Software the TRAQC 3 series dry block calibrators communicate with a PC This MS Windows based software is completely MENU controlled and allows the user to program pre fixed calibration routines and run calibration routines fully automatically N The environment temperature and draught length and the mass of the probe may influence the measurement considerably If the manufacturer has enabled pushbutton used for factory settings one has SS access to a part of a menu structure Use of this feature is not required any change may seriously change
13. rage and or shipping Before storage and or shipping the TRAQC 3 LH must be cooled to a temperature below 50 C The sequence to cool down the TRAQC 3 LH is described in chapter 4 3 After the TRAQC 3 LH is cooled down turn the TRAQC 3 LH off and unplug the mains power cord When the TRAQC 3 LH is shipped stored e Place the insulation tube in the Insulation tube storage hole e Remove the insert from the heat block and store the insert in one of the two insert storing holes or in the insert storing hole in the shipping case e Store it indoors in a temperature between O and 50 Celsius e Place the case a horizontal position 5 6 Recalibration The TRAQC 3 LH is adjusted and tested with measuring equipment in accordance with recognized national standards prior to delivery The TRAQC 3 should depending on the application situation be inspected at appropriate intervals We recommend you to return the calibrator to Tradinco Instruments at intervals of max 12 months for recalibration and service TRAQC 3 LH 07 2014 EN Rev 1 page 14 Se Tradinco lt Enders User Manual TRAQC 3 LH 6 Product Specifications 6 1 General Display Dual digit led displays Upper 10mm Lower 8mm Resolution 4 digits 0 1 C F Switch test Powerless switch LED indicator 5 VDC 16mA max Interface RS232 for use with AutoCal Software Supply voltage Power consumption Fault protection 230VAC 50 60 Hz 1800
14. rantees that this product will be free from defects in materials and workmanship for a period of 5 years from the date of shipment If any such product proves defective during this warranty period TRADINCO INSTRUMENTS at its option will either repair the defective product without charge for parts or labour or will provide a replacement in exchange for the defective product In order to obtain service under this warranty Customer must notify TRADINCO INSTRUMENTS of the defect before the expiration of the warranty period and make Suitable arrangements for the performance of the service Customer shall be responsible for packaging and shipping of the defective product to the service centre designated by TRADINCO INSTRUMENTS with shipping charges prepaid If no defect can be found Customer may be charged for costs of the investigation This warranty does not apply to any defect failure or damage caused by Improper use of the instrument Normal wear of the product Modification or repair carried out by or on behalf of the owner or by a third party Implementation of modifications to the product that are not supplied or implemented by TRADINCO INSTRUMENTS anD TRADINCO INSTRUMENTS and its vendors will not be liable for any indirect special incidental or consequential damages irrespective of whether TRADINCO INSTRUMENTS or the vendor has advance notice of the possibility of such damages The type number of the product as listed on the in
15. strument tag plate should always be mentioned in any correspondence concerning the product TRADINCO INSTRUMENTS Industrieweg 74 Postbus 37 2650 AA Berkel en Rodenrijs The Netherlands 31 0 10 5112911 www tradinco com info tradinco com TRAQC 3 LH 07 2014 EN Rev 1 page 3 s Tradinco C DE User Manual TRAQC 3 LH 1 2 TRAQC 3 LH Description The use of model TRAQC 3 LH offers a number of great advantages above eg alternative methods of temperature calibration but requires that any user reads the instruction manual very carefully and is aware of the fact that high temperature has to be handled with care and only in areas without hazardous fumes or fire risks and get acquainted with all the facilities offered by this temperature calibrator Accurate temperature measurements can be assured only when it is possible physically to produce a legitimate basis for establishing traceability to temperature standards The TRAQC 3 LH dry block calibrator is a high precision temperature calibrator ranging from 50 C to 650 C By setting the TRAQC 3 LH a series of different temperatures the inserted sensor display recorder can be calibrated accordingly The maximum probe diameter is 26mm and block depth is 180mm The TRAQC 3 LH consists of 5 main parts e The heating block is made from specially produced metal to achieve optimum heat conductivity and prevent corrosion The heating block is heated with resistance heating el
16. the behaviour of the instrument 4 2 Temperature switch e Connect the temp switch to the temperature switch 4mm sockets and insert the switch in the boring of the insert e With the up and down pushbuttons the desired temperature can be set between ambient 5 C and 650 C AN Make sure the upper grill is not blocked e Observe at least 35 minutes stabilisation time when the set temperature is reached in order to achieve the specified stabilization accuracy e Adjust or check the temp switch so that the switching indicator led switches at the desired temperature 4 3 End of use Do not switch the instrument off or disconnect the mains lead until the instrument has reached a temperature below 70 C e In order to cool down the TRAQC 3 LH quickly set the set temperature to 50 C When a temperature below 70 C is reached turn off the TRAQC 3 LH TRAQC 3 LH 07 2014 EN Rev 1 page 12 Se Tradinco lt Eene User Manual TRAQC 3 LH 5 Maintenance Before any maintenance is undertaken the TRAQC 3 LH must be cooled to room AN temperature The sequence to cool down the TRAQC 3 LH is described in chapter 4 3 When the TRAQC 3 LH is unplugged wait until it is cooled down to room temperature and unplug the mains power cord 5 1 Cleaning TRAQC 3 LH heat block and inserts A small amount of dust or pollution can cause jams when between the inserts and the heat block well To prevent this e