Home

A9GT-50PRF Type Printer interface module User`s Manual

image

Contents

1. 3 INSTALLATION PROCEDURE 1 The A9GT 50PRF is installed onto the option unit installation holes of the GOT with the A9GT 50PRF installation screws When using a communication unit with the A958GOT or when the A9GT 50PRF is not to be mounted on the back of the GOT install the A9GT 50PRF on the control panel Refer to the A950GOT A951GOT A953GOT A956GOT User s Manual for details on installing onto the control panel 2 Tighten the installations screws within the range of specified torque 36 to 48Necm 3 7 to 4 9kgfecm 3 2 to 4 2 Ibeinch 3 Mount the GOT side connection connector to the option module interface on the lower side of the GOT GOT side connector 4 Connect the A9GT 50PRF and printer with the connection cable Refer to the GOT A900 Series User s manual Connection System Manual for the usable printers To remove the unit reverse the installation procedure If the printer malfunctions characters are unrecognizable or characters are skipped etc because of noise etc the user should make an FG wire and ground to the A9GT 50PRF FG terminal block The methods for making the FG wire are shown below A9GT 50PREF side FG wire Crimp terminal M4 stranded wire equivalent to UL1015 AWG14 4 OUTLINE DIMENSION DRAWING FG terminal block
2. E 3 2 42 6 las z 9 5 92 3 62 0 13 1 68 0 14 G 0 37 105 4 13 450 17 71 44 1 73 49 3 5 1 94 5 DODDO Lae NNN Parallel interface Unit mm inch Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties A For safe use e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel Country Region Sales office Tel U S A Mitsubishi Electric Automation Inc Hong Kong Ryoden Automation Ltd 500 Corporate Woods Parkway Vernon 10th Floor Manulife Tower 169 Electric Hills IL 60061 Road North Point HongKong Tel 1 847 478 210
3. 0 Tel 852 2887 8870 Brazil MELCO TEC Rep Com e Assessoria China Ryoden Automation Shanghai Ltd Tecnica Ltda 3F Block5 Building Automation Rua Correia Dias 184 Edificio Paraiso Trade Center 8 andar Paraiso Sao Paulo SP Brazil Instrumentation Plaza 103 Cao Bao Rd Shanghai 200233 China Tel 86 21 6120 0808 Tel 55 11 5908 8331 Taiwan Setsuyo Enterprise Co Ltd Germany Mitsubishi Electric Europe B V German 6F No 105 Wu Kung 3rd RD Wu Ku Branch Hsiang Taipei Hsine Taiwan Gothaer Strasse 8 D 40880 Ratingen Tel 886 2 2299 2499 GERMANY Korea HAN NEUNG TECHNO CO LTD Tel 49 2102 486 0 1F Dong Seo Game Channel Bldg U K Mitsubishi Electric Europe B V UK 660 11 Deungchon dong Kangsec ku Branch Seoul Korea Travellers Lane Hatfield Herts AL10 Tel 82 2 3660 9552 8XB UK Singapore Mitsubishi Electric Asia Pte Ltd Tel 44 1707 276100 J l i 0 Italy Mitsubishi Electric Europe B V Italian Mitsubishi Electric Building Branch Singapore 159943 Centro Dir Colleoni Pal Perseo Ingr 2 Tel 65 6473 2308 Via Paracelso 12 20041 Agrate B Thailand F A Tech Co Ltd th Milano Italy 898 28 29 30 S V City Building Office Tel 39 039 6053344 Tower 2 Floor 17 18 Rama 3 Road 307 Alexandra Road 05 01 02 Spain Mitsubishi Electric Europe B V Spanish Bangkpongpang Yannawa Branch Bangkok 10120 Carretera de Rubi 76 80 Tel 66 2 682 6522 08190 Sant Cugat del Valles Indonesia P T Autoteknindo SUMBE
4. CAUTIONS A CAUTION Do not disassemble or modify this module This will cause failure malfunction injuries or fire Do not hold the cable part when unplugging any cable connected to the module Doing so can cause module or cable damage or a malfunction due to a cable contact fault Always make sure to touch the grounded metal to discharge the electricity charged in the body etc before touching the module Failure to do so may cause a failure or malfunctions of the module DISPOSAL PRECAUTIONS Z CAUTION When disposing treat this product as industrial waste 1 OVERVIEW This user s manual explains the A9GT 50PRF type printer Interface module referred to as the A9GT 50PRF A9GT 50PRF is connected to the A950GOT A951GOT A953GOT A956GOT referred to as the GOT and is used when printing data such as the alarm history function Refer to the Drawing software help functions for details on the alarm history function etc When using this unit version H or higher of the SW1D5C GOTRE PACK is required After opening the container check that the following products are present Quantity A9GT 50PRF 2 PERFORMANCE 2 1 Performance specifications tom O specifications Interface Parallel interface 1channel 24VDC Current consumption A AC30P10 20P cable length 3m Weight g Ib 250 0 55 2 2 Parallel interface specificatons When fabricating the printer cable on the user side conform to
5. MITSUBISHI ASGT 50PRF Type Printer interface module User s Manual Thank you for purchasing the MELSEC GOT Series To ensure correct use of this equipment please carefully read this manual prior to use A9GT 50PREF U Type y 1DM110 IB NA 0800019 C 0410 MEE Mitsubishi Graphics Operation Terminal Manuals Relevant Manual For relevant manuals refer to the PDF manual stored within the drawing software 1999 MITSUBISHI ELECTRIC CORPORATION SAFETY PRECAUTIONS Read these precautions prior to use When using Mitsubishi equipment thoroughly read this manual and the associated manuals that are introduced in this manual Also pay careful attention to safety and handle the module properly These precautions apply only to Mitsubishi equipment Please refer to the relevant user s manuals for safety precautions pertaining to Mitsubishi programmable controller systems and Graphics Operation Terminal abbreviated as GOT hereafter The SAFETY PRECAUTIONS in this manual are classified into two categories DANGER and CAUTION DANGER Procedures which may lead to a dangerous condition and cause death or serious personal injury if not observed as directed NCAUTION Procedures which may lead to a dangerous condition and cause minor to medium personal injury or damage only to property if not observed as directed i Depending on circumstances procedures indicated with CAUTION could also lead to s
6. R MAKMUR Barcelona Spain JI Muara Karang Selatan Block a Utara Tel 34 93 565 3131 No 1 Kav No 11 Kawasan Industri France Mitsubishi Electric Europe B V French Pergudangan Jakarta Utara 14440 Branch Tel 62 21 663 0833 India Messung Systems Put Ltd 25 Boulevard des Bouvets F 92741 Electronic Sadan NO 111 Unit No15 Nanterre Cedex France M 1 D C BHOSARI PUNE 411026 India TEL 33 1 5568 5568 Tel 91 20 712 2807 South Africa Circuit Breaker Industries LTD Australia Mitsubishi Electric Australia Pty Ltd Tripswitch Drive Elandsfontein Gauteng 348 Victoria Road PostalBag No 2 South Africa Rydalmere N S W 2116 Australia Tel 27 11 928 2000 Tel 61 2 9684 7777 a MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE 1 8 12 OFFICE TOWER Z 14F HARUMI CHUO KU 104 6212 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHL KU NAGOYA JAPAN When exported from Japan this manual does not require app of Economy Trade and Industry for service transaction per Specifications subject to change without notice Printed in Japan on recycled paper
7. erious results In any case it is important to strictly observe the directions indicated with the above signs Keep this manual in a place which allows you to easily reach it whenever necessary Please make sure that the end user of this equipment be provided with this manual DESIGN PRECAUTIONS amp DANGER Some failures of the GOT main unit this module or cable may keep the outputs on or off An external monitoring circuit should be provided to check for output signals which may lead to a serious accident Not doing so can cause an accident due to false output or malfunction INSTALLATION PRECATIONS amp DANGER Always turn the GOT power OFF before mounting this module onto the GOT main unit Not doing so can cause a module failure or malfunction Always turn the GOT power OFF before connecting the connection cable to this module Not doing so can cause a module failure or malfunction A CAUTION Use this module in the environment given in the general specifications of the GOT User s Manual Not doing so can cause an electric shock fire malfunction or product damage or deterioration When installing this unit to the GOT fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range Undertightening can cause a drop failure or malfunction Overtightening can cause a drop failure or malfunction due to GOT or screw damage STARTUP AND MAINTENANCE PRE
8. the following specifications item Specifications Compliant Centronics See below for the data and control signal timing standeed Signal ViH 2V VIL 0 8V level VOH 2 4V VOL 0 5V eae Within 3m or within the specifications of the printer used item Specifications DATA1 to 8 sendingside receiving side STROBE sendingside receiving side BUSY sendingside receiving side ACKNLG sendingside receiving side Note 1 1 Minimum 1 0us 2 Minimum 1 0us Maximum 500us 3 Minimum 2us Note 2 BUSY rises after fall of STROBE Note 3 ACKNLG is sent within 10s after fall of BUSY GOT connector 110220 52A2JL Cable connector 10120 6000EL Type insulation displacement type connector Cable connector cover 10320 3210 000 Timing chart 3M make no Sona aL NO Sona Pageto CHASIS GND DATA8 ASTIE 2 ACKNLG DATA7 RF S 3 DATA6 arinen pin 20 10 4 DATA5 SLCT Outs DATAA a 8 DATA1 18 GND 9 STROBE 19 ERROR GOT side cy ra Printer side CHASIS GND t H CHASIS GND ACKNLG i i ACKNLG DATA6 DATA6 DATA5 DATA5 DATA4 m i i DATA4 NC NC INIT INIT DATA1 DATA1 STROBE STROBE BUSY BUSY Wiring diagram DATAS _ l DATAS DATA7 i f DATA7 PE Ha 4 PE SLCT c c SLCT GND GND DATA3 DATA3 DATA2 c DATA2 GND GND ERROR ERROR GND c m GND

Download Pdf Manuals

image

Related Search

Related Contents

。 サン 一50N  législation pharmaceutique  Du "Notre Père" à la Loi de Dieu  Toshiba A105-S4344 Personal Computer User Manual  US-JEWELRY-PRO - User Manual  - Intersat  Satellite Pro L770-10W - Spécifications produit  ACS800 08/11 PDF, 2.7 MB  Proyector Full HD de 1080p  

Copyright © All rights reserved.
Failed to retrieve file