1. IMG W6121 M12 Industrial Cellular M2M Gateway with IEEE802 11 a b g n User Manual Version 1 1 January 2015 www oring networking com ORing Industrial Networking Corp 2 ORing TGAR 1062 2062 1662 Series User Manual COPYRIGHT NOTICE Copyright 2015 ORing Industrial Networking Corp All rights reserved No part of this publication may be reproduced in any form without the prior written consent of ORing Industrial Networking Corp TRADEMARKS ORing is a registered trademark of ORing Industrial Networking Corp All other trademarks belong to their respective owners REGULATORY COMPLIANCE STATEMENT Product s associated with this publication complies comply with all applicable regulations Please refer to the Technical Specifications section for more details WARRANTY ORing warrants that all ORing products are free from defects in material and workmanship for a specified warranty period from the invoice date 5 years for most products ORing will repair or replace products found by ORing to be defective within this warranty period with shipment expenses apportioned by ORing and the distributor This warranty does not cover product modifications or repairs done by persons other than ORing approved personnel and this warranty does not apply to ORing products that are misused abused improperly installed or damaged by accidents Please refer to the Technical Specifications section for the actual warranty period
2. LAN Link LAN Link LAN Link WAN Link j OPEN VPN Sever VPN Link Client PC Server PC WAN PC Open VPN Server and Client Connection ORing Industrial Networking Corp 39 ORing IMG W6121GT M12 User Manual Networking Setting gt Vpn Setting gt Openvpn penypn settings Server settings Cipenvpn Server Enable Oisable Interface Type TAP Tunnel Protocol UOP Port 1194 Redirect Gateway Manage Client Specific Options LO Compression Enable Disable Keys Setting Auto Diagnosis Client settings Cipenvpn Client Enable Disable server IP Host Name Interface Type TAP Tunnel Protocol UDP Port 1194 Test Site L Same as Event SMS gt VPN IP field Reconnect on Enable Failure LO Compression Enable o Disable Keys Setting Auto Diagnosis Open VPN Server Enables or disables the function of Open VPN server Interface Type Support TAP mode and TUN Mode Tunnel Protocol Select UDP or TCP protocol depending on your needs TCP is more reliable than UDP but UDP performs better than TCP It is recommended to use UDP if the distance between VPN server and client is short otherwise use TCP pan The number of the port default is 1194 Redirect Gateway Check this box will force all traffic to be routed through the VPN tunnel Manage Client Specific Check this box will allow VPN clients to access each Options other s shared resou
3. IPSec VPN IPSec VPN Settings IPSec YPM O Enable Disable VRRP A VRRP Virtual Router Redundancy Protocol is a computer networking protocol aimed to eliminate the single point of failure by automatically assigning available IP routers to participating hosts Using a virtual router ID VRID address and virtual router IP VRIP address to represent itself a virtual router consists of two or more physical routers including one master router and one or more backup routers All routers in the virtual router group ORing Industrial Networking Corp 45 ORing IMG W6121GT M12 User Manual share the same VRID and VRIP The master router provides primary routing and the backup routers monitor the status of the master router and become active if the master router fails Virtual Router PC Networking Setting gt VRRP Setting gt VRRP Setting VERR HIVI Sl Router Redundancy Protocol settings VRRP Protocol Enable Disable VRRP Instance State Master Backup Virtual Router IL 1 Virtual Router IF 192 166 10 2 Priority 100 1 254 Authentication Password ORing Industrial Networking Corp 46 ORing IMG W6121GT M12 User Manual VRRP Protocol Enables or disables VRRP function VRRP Instance State Specifies the gateway to act as the master or backup router Virtual Router ID A VRID consists of one master router and one or more backup routers The master router is the router that owns the IP address you a
4. require mschap v2 require mppe Routing ption Enable Routing Protocols through PP TP YPN Connection CHAP Secrets admin admin PPTP Server Enables or disables PPTP VPN server Server IP Enter the server IP address The default value is the IP address of Ia a er Client IP Enter the IP address range in the form of 192 168 10 xx xx The Ar ann nee PPP Options Require chap check to use chap authentication on your PPTP server Require mschap check to use mschap authentication on your PPTP server Require mschap v2 check to use mschap v2 authentication on your PPTP server Require mppe check to use MPPE Microsoft Point to Point Encryption encryption on data transmitted through PPP Point to Point Protocol and VPN links Routing Option Check to enable routing protocols through PPTP VPN connections CHAP Secrets Enter the username and password pairs in the form of user pass Multiple username and password pairs are allowed PPTP Client If a gateway wants to link to the gateways in different networks you should enable PPTP client in the following page ORing Industrial Networking Corp 43 ORing IMG W6121GT M12 User Manual WAN Line WAN Line WAN Line PPTP VPN Line d j LAN Line LAN Line af PPTP VPN Client PC WAN PC Server PC Networking Setting gt Vpn Setting gt PPTP Client PPTP Client settings PFIFP clent Enable Disable Server IF Hostname sername Password
5. CTS mechanism will not be enabled This is the wireless device s transmission power and is typically measured in dBm With greater Tx power greater transmission distances can be achieved Wireless Mode You can select 802 11 b b g or b g n mode Max Client Threshold SSID Broadcast This is the maximum number of clients for an AP When the number of clients exceeds the value the AP will reject the roaming connection This value is only used on AP mode equipment Available values include Long and Short with Long as the default value If all clients and access points in your wireless network support short preamble then enabling it can boost overall throughput However if any wireless device does not support short preamble then it will not be able to communicate with your network If you are not sure whether your radio supports the short RF preamble you must disable this feature When wireless clients survey the local area for wireless networks to associate with they will detect the SSID broadcasted by the AP Click Enable if you want to broadcast the AP SSID otherwise click Disable to inactivate the function ORing Industrial Networking Corp 32 ORing IMG W6121GT M12 User Manual Roaming Select Disabled to disable X Roaming protocol or select X roaming to enable X Roaming protocol Scan Channel Select All to scan all supported channels or Manual to scan only selected channels specified in
6. Event NCAA a nn sde a en de cs ee 54 EEE 55 do ae E 57 A T TTT 58 SVT E AMO A E E E Seba mmeieetematarisawmsbeutennMeneamesseaiacn lentes 58 SOS EE 59 MAND TT TT 59 Ka Ve Er NE SE RE 60 Technical Specifications sean nn an un 61 COMPARE den nsdt ts 63 ORing Industrial Networking Corp 3 ORing IMG W6121 3G M12 User Manual Getting Started 1 1 About the IMG W6121 3G 4G M12 The IMG W6121 3G 4G M12 is an innovative IEEE802 11 a b g n WLAN access point VPN gateway with two RS 232 serial ports and one 10 100 1000Base T X port The combination of two serial ports and one Ethernet port allows the device to connect to serial devices and networked devices at the same time The device can be configured to connect to the Internet by dialing up the 3 5G 4G cellular modem Therefore it can be used in various applications through WLAN connections With an IP 67 waterproof casing and PoE support IMG W6121 3G M12 can be deployed in harsh outdoor environments where power supply is difficult to come by Furthermore the device can also transfer SSL encryption data to five host PCs simultaneously for backup purposes 1 2 Software Features R High speed air connectivity for up to 300Mbps R High security with support for WEP WPA WPA PSK TKIP AES WPA2 WPA2 PSK TKIP AES 802 1X RADIUS authentication Support Open VPN PPTP VPN Versatile modes with redundant multiple host devices Supports 5 host devices Virtual COM TCP Server TCP Client mode
7. Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage est susceptible d en compromettre le fonctionnement Industry Canada Class B This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of Industry Canada Cet appareil num rique respecte les limites de bruits radio lectriques applicables aux appareils num riques de Classe B prescrites dans la norme sur le material brouilleur Appareils Num riques NMB 003 dict e par l Industrie ORing Industrial Networking Corp 63 ORing IMG W6121GT M12 User Manual Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device L op ration est soumise aux deux conditions suivantes 1 cet appareil ne peut causer d interf rences et 2 cet appareil doit accepter toute interference y compris celles susceptibles de provoquer fonctionnement du dispositif To reduce potential radio interference to othe
8. Radio Button Beacon Interval OTIM Interval Fragmentation Threshold RTS Threshold Tx Power Wireless Mode Max Client Threshold Preamble SSID Broadcast HT Require HT Band idth HT Guard Interval HT Extension Channel All eee HT Rix STBC ll OEEC ON GOFF 100 msec range 20 1000 default 100 1 range 1 255 default 1 2546 range 286 2546 default 2546 234 7 range 1 2347 default 234 7 range 0 16 default 16 B Mode Bis Mixed Mode BON Mixed Mode A Mode AN Mixed Mode 255 range 1 2007 default 255 Long Short Disable x Enable s Disable Enable 20 MHZ s 2040 MHz Long Short NULL Disable Enable s Disable Enable Disable Enable Extra parameters for Client Mode Roaming Scan Channel Channel Select Sensitivityidim Scan Intervall sec Disabled o roaming All Manual ex 6 or 12 13 Z range 1 20 default 5 30 range 1 60 default 30 Radio Button Enables or disables wireless function Beacon Interval A beacon is a packet sent by a wireless access point to synchronize wireless devices The beacon interval value indicates the frequency interval of the beacon Increasing the beacon interval reduces the number of beacons and the overhead associated with them The default value is 100 but 50 is recommended when reception is poor DTIM Interval A DTIM interval determines how often a beacon frame includes a Delivery Traffic Indication messag
9. UserName Enter the user name provides by yourlSP Password Ping Test Site ORing Industrial Networking Corp 13 ORing IMG W6121GT M12 User Manual Radio Type Select a type of radio from the list which includes GSM UMTS and LTE UIM Status Shows the status of SIM card Operations Click Connect to start modem 3G connections or Disconnect to shut down connections Link Status Shows the status of connections Modem Status Shows information about the modem WAN Connection Type as Wireless Client Basic Setting gt WAN WAM Settings VAY Wireless Client Y Connection Type IP Contig setting Obtain an IP address automatically Use the following IP address IF Address anan Subnet Wask anan Default Gateway Obtain DNS server address automatically Use the following DNS server addresses Preferred ONS Alternate ONS Wireless Client Setting Feer AF Site Survey aal Hidden Show Site Table security Options Security Mone Type Use Modem sG as backup connection APH User Name Password Ping Test IQ Address ORing Industrial Networking Corp 14 ORing IMG W6121GT M12 User Manual Obtain an IP address Select this option if you want the IP address of the WAN port to Use the following IP Select this option if you want to assign an IP address to the address WAN port manually You should set IP Address Subnet Mask and Default Gateway according
10. also supports up to 5 simultaneous connections so that multiple hosts can send or receive data by the same serial device at the same time ORing Industrial Networking Corp 25 ORing IMG W6121GT M12 User Manual Serial Setting gt Service Mode Pati Y Data Encryption Enable Disable Service Mode Vital COM Mode Y idle Timeout 0 U 6S5g5 seconds Alive Check AQ U 6S5g5 seconds Max Connection 1 Y Max connection 1 2 Data Encryption Use SSL to encrypt data When serial port stops data transmission for a defined period of time Idle Timeout the connection will be closed and the port will Idle Timeout be freed and try to connect with other hosts 0 indicate disable this function Factory default value is 0 If Multilink is configured only the first host connection is effective for this setting The serial device will send TCP alive check package in each defined time interval Alive Check to remote host to check the Alive Check TCP connection If the TCP connection is not alive the connection will be closed and the port will be freed 0 indicate disable this function Factory default is 0 The number of maximum connections can be supported The Max Connection maximum value is 5 default values is 1 Not allowed to mapping Virtual COM from web TCP Server Mode In TCP Server mode IMG is configured with a unique port combination on a TCP IP network In this case IMG waits passively to be contacted
11. and 2xRS 232 0 Band open all S Home M Basic Setting Welcome to Industrial 4G M2M Gateway with IEEE802 11 a b g n 1x10 100 1000Base T X PoE P D and M Networking Setting 2xRS 232 configuration page M system Tools M System Status amp Logout 5 2 Configuration On top of the Home screen shows information about the firmware version uptime and WAN IP address Industrial 4G M2M Gateway with IEEE802 11 a b g n 1x10 100 1000Base T X PoE P D and 2xRS 232 0 Band Firmware Ver 1 1s Uptime S 30s 5 2 1 Basic Setting This section will guide you through the general settings for the gateway WAN This page allows you to configure WAN settings Different WAN connection types will have ORing Industrial Networking Corp 12 ORing IMG W6121GT M12 User Manual different settings WAN Connection Type as Modem 3G Basic Setting gt WAN WAN Settings WAN ModemaG N Connection Type APM APN2 APN User Mame Password Ping Test Site FIM Enable PIN check before dialing PIN Code Auto Connect Enable Reconnect on Enable Failure signal Quality Thresholdidbmy 85 derault 55 Using Ping Test Interval SZ counts Radio Type gsm amp umts amp Ite Y JiM Status not present Operations Lonnect Disconnect Diagnosis Detect Link Status Connecting Modem Status Liperator Unknown Radio Type gsm Signal Quality 105d6m Rost 4 ABN Enter the APN value optional
12. application that generates this port forwarding Ext Port The port opened on WAN Protocol The protocol type Int Port The port redirected to the local computer IP Address The IP address of local computer to be redirected to Firewall Setting IP Filter IP filters enable you to control the forwarding of incoming and outgoing data between your LAN and the Internet and within your LAN This control is implemented via IP filter rules which are defined to block attempts by certain computers on your LAN to access certain types of data or Internet locations You can also block incoming access to computers on your LAN Networking Setting gt Firewall Setting gt IP Filter IP filter settings IP Filter Enable Disable Description Fule DROP Y Direction LAN VVAN Y IP Address Source IF Destination IP Protocol All CMP Specify protocol number S CF Specify port UDP Specify port Enable Mow K Yes No Acid Cancel IP filter list Source Destination D IP IP Filter Enables or disables the IP Filter Description Rule Direction Protocol Port Enabled Operations Enter description for the entry Configures the rules to be applied to the IP filter Available options include DROP ACCEPT and REJECT Direction Specifies the direction of data flow to be filtered ORing Industrial Networking Corp 36 ORing IMG W6121GT M12 User Manual IP Address Enter the IP address of the source and desti
13. by the device After the device establishes a connection with the serial device it can then proceed with data transmission The TCP Server mode also supports up to 5 simultaneous connections so that multiple device can receive data from the same serial device at the same time ORing Industrial Networking Corp 26 ORing IMG W6121GT M12 User Manual Serial Setting gt Service Mode Forti Y Data Encryption Enable Disable Service Mode TCP Server Mode Y TCP Server Port 4002 Idle Timeout 0 0 659539 1seconds Alive Check AQ U H5535 seconds Max Connection 1 Y max connection 1 5 Data Encryption Use SSL to encrypt data TCP Server Port Set the port number for data transmission When serial port stops data transmission for a defined period of time Idle Timeout the connection will be closed and the port will Idle Timeout be freed and try to connect with other hosts 0 indicate disable this function Factory default value is 0 If Multilink is configured only the first host connection is effective for this setting The serial device will send TCP alive check package in each defined time interval Alive Check to remote host to check the Alive Check TCP connection If the TCP connection is not alive the connection will be closed and the port will be freed 0 indicate disable this function Factory default is 0 The number of maximum connections can be supported The Max Connection maximum value is 5 default values i
14. from HTTP and HTTPS HTTPS HTTP over SSL encrypis data sent and received over the Web Choose HTTPS if you want a secure connection Choose a web management page port number For HTTP default port is 80 For HTTPS default port is 443 M2M Restart This page allows you to configure restart settings for the gateway System Tools gt Router Restart Router Restart Utility estat Mow Scheduling Enable Restat Every Day via 00 v OO Restart Now Click to restart the gateway via warm reset Enable check to activate the setting Restart at specify the time for resetting the gateway You can configure the action to be performed periodically ORing Industrial Networking Corp 51 ORing IMG W6121GT M12 User Manual Firmware Upgrade ORing launches new firmware constantly to enhance gateway performance and functions To upgrade firmware download new firmware from ORing s website to your PC and install it via Web upgrade Make sure the firmware file matches the model of your gateway It will take several minutes to upload and update the firmware After upgrade completes successfully reboot the gateway System Tools gt Firmware Upgrade Do NWOT power off the router while upgrading Current Firmware Version 1 18 BBS HEREA start web Upgrade During firmware upgrading do not turn off the power of the gateway or press the reset button Save Restore Configurations This page allows you to save con
15. gt Firewall Setting gt Custom Rules Custom firewall rules Custom Firewall Rules Enable Disable Note Each command line must precede with iptables Vpn Setting Open Vpn A VPN is a method of linking two locations as if they are on a local private network to facilitate data transmission and ensure data security The links between the locations are known as tunnels VPN can achieve confidentiality authentication and integrity of data by utilizing encapsulation protocols encryption algorithms and hashing algorithms Open VPN enables you to easily set up a virtual private network over an encrypted connection It is a full function SSL VPN solution which accommodates a wide range of configurations including remote access site to site VPNs WiFi security and enterprise level remote access with load balancing failover and fine grained access control features To set up your gateway as an Open VPN server you need to install openvpn client software for your Windows based PC You can download it from http openvpn net download html stablel ORing Industrial Networking Corp 38 ORing IMG W6121GT M12 User Manual WAN Link WAN Link OPEN Sever Offic PC Connection to Open VPN Server When you enable Open VPN Client you need two gateways to create site to site VPN connections The server IP and client IP address should be within the same network domain WAN mf OPEN VPN Client d x
16. purposes such as gaming To use this function you need to set an internal computer as the DMZ host by entering its IP address Adding a client to the DMZ may expose your local network to a variety of security risks so use this function carefully Networking Setting gt NAT Setting gt DMZ DMZ settings Ch Enable Ulsable Description OM Host IP DMZ Enables or disables DMZ Enter a description for the DMZ host entry DMZHostIP Enter the IP address of the computer to act as the DMZ host NAT Setting UPnP The UPnP Universal Plug and Play feature allows Internet devices to access local host resources or devices as needed UPnP enabled devices can be automatically discovered by the UPnP service application on the LAN Networking Setting gt NAT Setting gt UPnP LUPnP settings UPnP Enabled Disabled Enable NAT PMP UPnP List a 2 Ext Int F Application Port Protocol Port IP Address usap Enable or disable UPnP Enable NAT PMP NAT PMP allows a computer in a private network behind a NAT router to automatically configure the gateway to allow parties outside the private network to contact with each other NAT PMP operates with UDP It essentially automates the process of port ORing Industrial Networking Corp 35 ORing IMG W6121GT M12 User Manual forwarding Check the box to enable NAT PMP UPnP List This table lists the current auto port forwarding information Application The
17. s of the product s associated with this publication DISCLAIMER Information in this publication is intended to be accurate ORing shall not be responsible for its use or infringements on third parties as a result of its use There may occasionally be unintentional errors on this publication ORing reserves the right to revise the contents of this publication without notice CONTACT INFORMATION ORing Industrial Networking Corp 3F No 542 2 JnongJheng Rd Sindian District New Taipei City 23148 Taiwan R O C Tel 886 2 2218 1066 Fax 886 2 2218 1014 Website www oring networking com Technical Support E mail support oring networking com Sales Contact E mail sales oring networking com Headquarters sales oring networking com cn China ORing Industrial Networking Corp 1 ORing TGAR 1062 2062 1662 Series User Manual Tables of Content LOTUS ATC H 1 1 1 About the IMG W6121 3G 4G M1 2 1 1 2 SoftWare a lt 1 1 3 EE L O D T A m2 2 VA SS AR 1 Hardware Overview nanas anna eenn ennenen 2 2 1 BOROM PNO ea r dene aces ttsteg eset bins E EEEE NE E EEE 2 Ziel POLS aid Connecti S renani EEEE EEN 2 alz Front Panel LED Secseca i e aaa 2 2 2 OPA E E EE AEEA E tore EE EER 3 Hardware Installation sssssssssssss sss sss sss sss sss ss essen enesenn enean ennenen d 3 1 MVE e ta ae RER RE 5 3 2 FO MOURIR a E nce sap a EE EE oo 7 Cables and ANED anne ann ne in 9 4 1 ETOH Eae D E laa a EEE T E 9 4 2 Serial POM Pin erle N s
18. the contiguous addresses in the IP address peer ae ee Lease Time The period of time for the IP address to be leased During the lease time the DHCP server cannot assign that IP address to any other clients Enter a number in the field The default setting is 48 hours Local Domain Name Enter the local domain name of a private network optional The DHCP will assign the entered domain to DHCP clients DNS Server 1 amp 2 Enter the IP address for the DNS server optional ORing Industrial Networking Corp 17 ORing IMG W6121GT M12 User Manual specifies the IP address of a local Windows NetBios Server if one is present in your network optional DHCP Range for Configure the DHCP range for relay by inputting a starting and Stating eaa IP tor the DHOP retyrange Ending IP The ending IP for the DHCP relay range Subnet Mask Enter a Subnet mask for the DHCP relay range List of DHCP Range Shows all IP addresses for the DHCP relay range for Relay Allocate IP Address By selecting an IP address from the drop down list and click Manually Copy to you can edit the MAC addresses and IP addresses already assigned by the gateway and add it to Static DHCP Client List MAC Address The MAC addresses of the computer IP Address The IP address to be related to the MAC address Static DHCP Client List Shows the IP addresses locked to specific MAC addresses is DHCP Client List This page shows you the IP address Host Name an
19. Channel Select Channel Select Assign the value roaming channels Sensitivity Configures signal sensitivity Scan Interval Configures scan interval MAC Filter This page allows you to set up MAC filters to allow or deny wireless clients to connect to the gateway You can manually add a MAC address or select a MAC address from the Associated Clients list currently associated with the gateway NetWorking Setting gt Wireless Setting gt MAC Filter Filters are used to allow or deny Wireless Clients from accessing the AP MAC Filters Enabled Disabled Options Only allow MAC address es listed below to connect to AP Only deny MAC address es listed below to connect to AP Associated Clients Choose an Associated Client Copy To Choose a Slot v MAC Filter Table 1 11 21 2 Pe Da E ee 2a d 14 24 B 15 Da D 16 25 T IF 2e D 15 20 3 al DE 10 20 a MAC Filter Select Enabled or Disabled to activate or deactivate MAC filters Select one of the options to allow or deny the MAC address in the list Associated Clients Shows the wireless MAC addresses associated with the gateway MAC Filter Table You can edit up to MAC addresses in these fields ORing Industrial Networking Corp 33 ORing IMG W6121GT M12 User Manual NAT Setting Virtual Server This page allows you to set up virtual server setting A virtual server allows Internet users to access services on your LAN This is a useful f
20. EN55022 class A EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 CS EMS EN61000 4 8 EN61000 4 11 Warranty 3 years ORing Industrial Networking Corp 62 ORing IMG W6121GT M12 User Manual Compliance FCC Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation RF exposure warning The equipment complies with RF exposure limits set forth for an uncontrolled environment The antenna s used for this transmitter must not be co located or operating in conjunction with any other antenna or transmitter You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment This device should be operated with minimum distance 20cm between the device and all persons Operations in the 5 15 5 25GHz band are restricted to indoor usage only Industry Canada Statement This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device
21. Options Reconnect on failure default route require chap require mschap require mschap 2 fequire mppe Routing Option Enable Routing Protocols through PRTR Client Connection Operations Connect Disconnect Link Status Disconnected ORing Industrial Networking Corp 44 ORing IMG W6121GT M12 User Manual PPTP Client Enables or disables PPTP client Server IP Hostname Enter the server IP address or hostname Username Password Enter the username and password assigned by PPTP server Choose the rules to be applied Reconnect on failure prompts automatic reconnection when the link fails Require chap check to use chap authentication on your PPTP server Require mschap check to use mschap authentication on your PPTP server Require mschap v2 check to use mschap v2 authentication on your PP TP server Require MPPE check to use MPPE Microsoft Point to Point Encryption encryption on data transmitted through PPP Point to Point Protocol and VPN links Click Connect to link to the server or Disconnect to disconnect Routing Option from the server Click Connect to link to the server or Disconnect to disconnect Operations from the server Link Status Show the status of the link IPSec VPN IPsec VPN provides secure IP communications by authenticating and encrypting each IP packet of a communication session Check to box to enables or disables the function Networking Setting gt Vpn Setting gt
22. Pin Definition The device has one 10 100 1000 Base T X Ethernet port According to the link type the device uses CAT 3 4 5 5e UTP cables to connect to any other network device PCs servers switches routers or hubs Please refer to the following table for cable specifications 10Base T Cat 3 4 5 100 ohm UTP 100 m 328 ft RJ45 100Base T X Cat 5 100 ohm UTP UTP 100 m 328 ft RJ45 _ 1000Base T X UTP 100 m 328 ft RJ45 SE 1 0 ORing Industrial Networking Corp 9 ORing IMG W6121GT M12 User Manual 4 3 Wireless Antenna The device provides two N type female connectors for Wi Fi antennas You can also use external RF cables and antennas with the connectors O ees 78 4 4 Cellular Antenna The device provides one cellular connector for 3G and 4G antennas External RF cables and antennas can also be used with the connector 78 ORing Industrial Networking Corp 10 ORing IMG W6121GT M12 User Manual Management 5 1 Network Connection Before installing the gateway you need to be able to access the gateway via a computer equipped with an Ethernet card or wireless LAN interface To simplify the connection it is recommended to use an Ethernet card to connect to a LAN ppa DD CC Wireless ll Recorder E RS232 IP Camera G Ethernet Data Center Ethernet M2M Gateway Connection Please Follow the steps below to install and connect the g
23. Relay Eth1 Link Down Fault LED Relay SMS You can configure the device to send notifications via SMS when the selected event occurs You need to provide the phone number with which you want to receive the notifications and the time intervals between delivery attempts System Tools gt Even Warning Settings gt SMS Log SMS Settings Cell Phone Mumper Send sMs Interval 10 SET ORing Industrial Networking Corp 57 ORing SMS Send Event Types Device Event Notification Hardware Reset Cold Start Software Reset Warm Start Login Failed WAN IP Address Changed Password Changed Redundant Power Changed Eth Link Status Changed SNMP Access Failed Wireless Client Associated Wireless Client Disassociated Client Mode Associated Client Mode Disassociated Client Mode Roaming WAN Ping Connected VPN Connected Fault Event Notification Power 1 Fault Power Fault POE Fault Eth1 Link Down 5 2 4 System Status System Info IMG W6121GT M12 User Manual SMS Trap SMS Trap SMS Trap SMS Trap SMS Trap SMS Trap SMS Trap SMS Trap SMS Trap SMS Trap SMS Trap SMS Trap SMS Trap SMS Trap SMS Trap SMS Trap SMS Trap SMS Trap SMS Trap This page displays the detailed information of the gateway including model name description firmware version WAN LAN and wireless settings ORing Industrial Networking Corp 58 ORing IMG W6121GT M12 User Manual System Status gt System Info Syst
24. Reset Warm Start SNMP Trap Login Failed SNMP Trap WAN IP Address Changed SNMP Trap Password Changed SNMP Trap Redundant Power Changed SNMP Trap Eth Link Status Changed SNMP Trap SNMP Access Failed SNMP Trap Wireless Client Associated SNMP Trap Wireless Client Disassociated SNMP Trap Client Mode Associated SNMP Trap Client Mode Disassociated SNMP Trap Client Mode Roaming SNMP Trap Fault Event Notification Power 1 Fault SNMP Trap Power Fault SNMP Trap POE Fault SNMP Trap Eth1 Link Down SNMP Trap SNMP Agent SNMP Simple Network Management Protocol Agent is a ORing Industrial Networking Corp 56 ORing IMG W6121GT M12 User Manual service program that runs on the access point The agent provides management information to the NMS by keeping track of various operational aspects of the AP system You can enable or disable the function SNMP Trap Server 1 4 Enter the IP address of the SNMP server which will send out traps generated by the AP Community Community is a password to establish trust between managers an and agents Normally public is used for read write community Relay You can select events to trigger relay action by checking the boxes in this section Available events include power failure POE power failure and Ethernet link disconnection System Tools gt Even Warning Settings gt Relay Fault LED Relay Power 1 Fault Fault LED Relay Power Fault Fault LED Relay POE Fault Fault LED
25. SS OFDM IEEE802 11a OFDM with BPSK QPSK QAM 64QAM IEEE802 11b CCK DQPSK DBPSK IEEE802 11g OFDM with BPSK QPSK 16QAM 64QAM IEEE802 11n BPSK QPSK 16 QAM 64 QAM America FCC 2 412 2 462 GHz 11 channels 5 180 5 240 GHz amp 5 745 5 825 GHz 9 channels Europe CE ETSI 2 412 2 472 Ghz 13 channels 5 180 5 240 GHz 4 channels IEEE802 11b 1 2 5 5 11 Mbps IEEE802 11a g 6 9 12 18 24 36 48 54 Mbps IEEE801 11n up to 300Mbps lia 12dBm 1 5dBm 11b 17dBm 1 5dBm 11g 15dBm 1 5dBm Transmit Power 11gn HT20 11gn HT40 iian HT20 iian HT40 lia 68dBm 2dBm 54Mbps 11b 85dBm 2dBm 11Mbps Receiver Sensitivity 119 68dBm 2dBm 54Mbps 11gn HT20 11gn HT40 ORing Industrial Networking Corp 13dBm 1 5dBm 150Mbps 12dBm 1 5dBm 300Mbps 12dBm 1 5dBm 150Mbps 12dBm 1 5dBm 300Mbps 68dBm 2dBm 150Mbps 68dBm 2dBm 300Mbps 61 ORing IMG W6121GT M12 User Manual 802 11an HT20 68dBm 2dBm 150Mbps BE stm 2 atmos WEP 64 bit 128 bit key supported WPA WPA2 802 11i WEP and AES encryption Encryption Security WPAPSK 256 bit key pre shared key supported 802 1X and Radius supported TKIP encryption Wireless Security SSID broadcast disable Serial Ports 2 8 pin M12 A coding Male connector LED Indicators Power Physical Characteristic Environmental 5 to 95 Non condensing Regulatory Approvals EMI FCC Part 15 CISPR
26. Supports 4 IP ranges UDP Event warning by Syslog e mail and SNMP trap 3 Hardware Features 1 x 10 100 1000Base T X PoE port P D 3 5G HSUDPA or 4G LTE modem included 2 x RS 232 serial ports 1 E E E R P 67 grade waterproof casing B Casing IP 67 R Operating temperature 25 to 70 C H Storage temperature 40 to 85 C R Operating humidity 5 to 95 non condensing a Dimensions 250 W x 220 D x 87 H mm 9 84 x 8 66 x 3 4 inch ORing Industrial Networking Corp 1 ORing IMG W6121GT M12 User Manual Hardware Overview 2 1 Bottom Panel 2 1 1 Ports and Connectors The series is equipped with the following ports and features on the front panel Description 1 x 10 100 1000 Base T X port supporting auto negotiation 1 x SIM card slot 2 x serial port 1 Serial ports 6 WLAN status LED 2 Power LED 7 Ethernet port status LED 3 Serial port 1 status LED 8 SIM card 4 Serial port 2 status LED 9 Ethernet port 5 WAN status LED 10 3G 4G antenna connector 2 1 2 Front Panel LEDs PWR Power is supplied over Ethernet Serial 1 2 Blinking Transmitting data ORing Industrial Networking Corp 2 ORing IMG W6121GT M12 User Manual Btinking Taranis cata WLAN is activated WLAN Green Blinking Transmitting data WAN Modem is connected 2 2 Top Panel On the top panel sits a SIM card slot and a cellular antenna connector as show as below i A i i EE i li d L i i L
27. Time 6 Hours Local Domain Name optional DNS Server 1 optional DNS Server 2 optionals WINS Server optional DHCP Range for Relay Need Apply to validate setting changes starting IP Ending IP Subnet Mask Add ORing Industrial Networking Corp 16 ORing IMG W6121GT M12 User Manual List of DHCP Range for Relay Staring IP Ending IP Subnet Mask Operations Allocate IP Address Manually Choose a Client to Edit i Copy ta MAC Address IP Address Operations Add Clear static DHCP Client List MAC Address IP Address Operations DHCP Mode Available options include Built in DHCP Server and DHCP Forwarder Built in DHCP Server will enable the gateway to automatically assign an IP address to a computer on the LAN DHCP Forwarder will forward DHCP messages to a server on the Internet to handle DHCP requests If you choose DHCP Forwarder enter a DHCP server IP address Set DHCP Server DHCP Mode DHCP Forwarder DHCP Server Location WAN PPTP Remote Peer DHCP Server IP Address DHCP Server Enables or disables the DHCP server function The default setting is Enabled The Starting and Ending DHCP addresses should be in the same subnet as the LAN IP address of the VPN firewall Specifies the first of the contiguous addresses in the IP address pool Any new DHCP client joining the LAN will be assigned an IP address between this address and the Ending IP Address Specifies the last of
28. al device is started Connect on Any The TCP Client will build TCP connections once the connected UDP Client Mode Compared to TCP communications UDP is faster and more efficient In UDP mode you can Uni cast or Multi cast data from the serial device server to host computers and the ORing Industrial Networking Corp 28 ORing IMG W6121GT M12 User Manual serial device can also receive data from one or multiple host Serial Setting gt Service Mode Service Mode Listen Port Host start IP 1 2 3 4 Port Y UOP Mode Y A002 Host end IF send Port 699439 bag do 699239 69939 Listen Port Host start IP end IP Send Port DDNS Allows the user to set a new TCP port number to listen on rather than the default value of the device If there are more than one destination hosts specify the IP address range by inputting a value in Host Start End IP You can also auto scan the sending port number of the device Set the send port number DDNS Dynamic Domain Name System allows you to configure a domain name for your IP address which is dynamically assigned by your ISP Therefore you can use a static domain name that always points to the current dynamic IP address Basic Setting gt DONS CONS settings DONS Service win dyndns org Y User Mame Password Domain DDNS Service Choose a DDNS service provider from the list UserName Enter the user name of your DDNS account Enter th
29. alance Rule s Enable Disable Description Load Balance Pool WAND source IP Address Enable Mow gt Yes Mo Add Cancel Load Balance Rule Description Load Balance Pool Source IP Enabled Operations Load Balance Rule Check to enable or disable the function Description Type the description for the rule Load Balance Pool Choose one of the profiles to be used by such rule Source IP Address Type a WAN IP address here as the source IP address for such rule Enable Now Check to activate the function immediately or at a later time 5 2 3 System Tools Login Setting You can change login name and password in page The default login name and password are both admin System Tools gt Login Setting Login settings Cid Login Name admin Old Password aman New Login Name admin New Password sens Confirm Mew a Password Web Protocol HTTP SNR S Part a0 ORing Industrial Networking Corp 50 ORing IMG W6121GT M12 User Manual Old Name Type in current login name Old Password Type in current password Enter a new login name Acceptable characters contain 0 9 a z A Z and the length must be 1 to 15 characters An empty name is not acceptable New Password Enter a new login password Acceptable characters contain 0 9 a z A Z and the length must be 0 to 15 characters Confirm New Password Retype the new password to confirm it Web Protocol Choose a web management page protocol
30. all Step 1 Attach the mounting plate to the back of the device using four screws The plate can be attached vertically or horizontally to the device based on the space available ORing Industrial Networking Corp 5 ORing IMG W6121GT M12 User Manual Vertical Step 2 Hold the device upright against the wall Step 3 Insert four screws through the large opening of the keyhole shaped apertures at the top and bottom of the plate and fasten the screw to the wall with a screwdriver ORing Industrial Networking Corp 6 IMG W6121GT M12 User Manual Instead of screwing the screws in all the way it is advised to leave a space of about 2mm to allow room for sliding the device between the wall and the screws 3 2 Pole Mounting You can mount the device to a pole using adjustable steel band straps included in the kit When installing the device to a pole Step 1 Attach the mounting plate to the back of the device using four screws The plate can be attached vertically or horizontally to the device based on the space available Vertical ORing Industrial Networking Corp 7 ORing IMG W6121GT M12 User Manual Horizontal Step 2 Thread the two supplied metal mounting straps through the large slots on the mounting plate and then put the straps around the pole Type 1 Type 2 Type 3 L ORing Industrial Networking Corp 8 ORing IMG W6121GT M12 User Manual Cables and Antenna 4 1 Ethernet
31. annel Shanel You can also select a new number from the dropdown list All devices on the network must be set to use the same channel to communicate on the network A WDS master is the central control point for authenticating wireless clients caching client key material distributing MFP key material reporting radio management information to an upstream WDS Master Mode oo network management station and updating other APs participating in WDS You can set the device as the WDS master by selecting from the list This function prevents devices connected to an AP from AP Isolation within SSID communicating directly with each other This function is useful when many wireless clients request your network frequently You can choose the security type for your WLAN connection from Security options the following options None no encryption ORing Industrial Networking Corp 19 ORing IMG W6121GT M12 User Manual WEP WEP Wired Equivalent Privacy is a wireless security protocol for WLAN WEP will encrypt data transmitted on the WLAN WPA WPA2 Personal uses a pre shared key for authentication This pre shared key is then dynamically sent between the AP and clients Each authorized computer is given the same pass phrase WPA WPA2 Enterprise this type includes all of the features of WPA WPA2 for 802 1x RADIUS authentication Personal plus support 802 1x authentication through a RADIUS server When you set se
32. ateway to PCs Step 1 Select a power source The device is powered via the PoE Power over Ethernet port so there is no need for additional power cords Step 2 Connect a computer to the device Use either a straight through Ethernet cable or cross over cable to connect the ETH1 port of the gateway to a computer Once the LED of the LAN port lights up which indicates the connection is established the computer will initiate a DHCP request to retrieve an IP address from the VPN gateway Step 3 Configure the device on a web based management utility Open a web browser on your computer and type htip 192 168 10 1 default gateway IP of the device in the address box to access the web page A login window will pop up where you can enter the default login name admin and password admin For security reasons we strongly recommend you to change the password Click on System Tools gt Login Setting after logging in to change the password ORing Industrial Networking Corp 11 ORing IMG W6121GT M12 User Manual Address 192 168 10 1 Be Connect to 192 168 10 1 x y Login User name Password After you log in successfully a Web interface will appear as shown below On the left hand side of the interface is a list of functions where you can configure the settings The details of the configurations will be shown on the right screen Industrial 4G M2M Gateway with IEEE802 11 a b g n 1x10 100 1000Base T X PoE P D
33. curity type as WEP the following fields will appear to allow you to configure individual settings Security Options Security Type AUTH Mode WEP Encryption Key Type T Open Shared WEPAUTO 64 Bit ASCII 5 characters Default Key Index 1 Y KEYT EY 2 KEYS KEYA Label Description Auth Mode WEP Encryption Key Type Available values include Open Shared and WEPAUTO When choosing Open or Shared all of the clients must select the same authentication to associate this AP If select WEPAUTO the clients do not have to use the same Open or Shared authentication They can choose any one to authenticate You can select 64 Bit or 128 Bit Available values include ASCII and Hex Key Type ASCII American Standard Code for Information Interchange is a code for representing English characters as numbers in the range from 0 to 127 Hex digits uses 0 9 to represent values zero to nine and characters A F to represent values ten to fifteen ORing Industrial Networking Corp 20 ORing IMG W6121GT M12 User Manual Default Key Index Select one of the keys to be the active key Key 1 to 4 You can input up to four encryption keys When you set security type as WPA WPA2 Personal the following fields will appear to allow you to configure individual settings Security Options Security Type Auth Mode e WPASPSOK WPAP SKAMPA ZP SK Encryption Type TRIP o AES TKIPES mix
34. d MAC address of each computer that is connected to your network If the computer does not have a host name specified then the Host Name field will be blank Basic Setting gt DHCP gt DHCP Client List Current DHCP Client Information HostName Expires In 1 android gQ 18 7c1bff c 192 168 10 62 1 days 22 12 30 c397c98916b59beb eon e duab L static IP Allocation Wireless LAN You can set the device to work in AP mode This is the most common mode for all wireless APs In this mode the AP will act as a central connection point which other wireless clients can connect to ORing Industrial Networking Corp 18 ORing IMG W6121GT M12 User Manual Basic Setting gt Wireless LAN gt AP These are the basic wireless settings for the Storage Router Basic wireless settings for the AP Wireless Enabled Disabled Multiple SSID Index SSID OOO000 Channel 6 Y WOS Master Mode Disabled Y AP Isolation within soll Disabled Security Options None WEF WIPAAYPA Personal WPAAYPA Enterprise 002 1 Security Type Apply Save Multiple SSID index The index of the SSID SSID Service Set Identifier is a unique name that identifies a network All devices on the network must be set with the same SSID in order to communicate with each other Fill in a new SSID in this field if you do not want to use the default value Specify a channel to be used Channel 6 is the default ch
35. e a message that informs the clients about the presence of buffered multicast broadcast data on the access point The message is generated within the periodic beacon at a frequency specified by the DTIM Interval When the AP sends a DTIM with a DTIM interval value the client hearing the beacons will awake to receive the messages The default value is 1 and the value must be between 1 and 255 ORing Industrial Networking Corp 31 ORing IMG W6121GT M12 User Manual Fragmentation Threshold RTS Threshold The value specifies the maximum size for a packet before data is fragmented into multiple packets The value should remain at the default 2346 the range is 256 2346 bytes If you experience a high packet error rate you may slightly increase the value Setting the value too low may result in poor network performance Only minor modifications of this value are recommended The RTS Request to Send Threshold is the amount of time a wireless device attempting to send will wait for a recipient to acknowledge that it is ready Normally the AP sends a RTS frame to a station and negotiates the sending of data After receiving the RTS the station responds with a CTS Clear to Send frame to acknowledge the right to begin transmission To ensure communication the maximum value should be used which is the default value 2347 the range is 0 2347 bytes If a network packet is smaller than the preset RTS threshold size the RTS
36. e password of your DDNS account Domain Enter the domain name provided by your dynamic DNS service provider ORing Industrial Networking Corp 29 ORing IMG W6121GT M12 User Manual Date amp Time In this page you can set the date amp time of the device A correct date and time will help the system log events You can set up a NTP Network Time Protocol client to synchronize date amp time with a NTP server on the Internet Basic Setting gt Date amp Time DateTime settings System time Thu Aug 02 2012 12 9 27 MTE c Enable NTP Server 1 pool ntp org NTP Server 2 time nist qov optional Time ONE UTC 06 00 Mexico City Svnchronise Every Day r aL OO O0 Local Date Ane Year jg Month 2 Day Local Time 12 Hour 9 MINUTE 24 second Get Current Date amp Time from Browser Synchronize Specify the scheduled time for synchronization Local Date Set a local date manually Local Time Set a local time manually Get Current Date amp Click to set the time from your browser Time from Browser 5 2 2 Networking Setting This section will guide you through various networking settings including wireless NAT firewall VPN VRRP and routing protocol Wireless Setting Advanced This page allows you to set up wireless configuration ORing Industrial Networking Corp 30 ORing IMG W6121GT M12 User Manual Advanced Setting gt Wireless Setting gt Advanced Wireless performance tunning
37. em Info Model Ihils VWib 12 14 h 12 45 Model Industrial 4G M2M Gateway with IEEE802 11 a b g n 1 10 100 1000Base TT POE P D and 2xRs 232 WAN Mode Modemid IP Address 192 168 2251 Subnet Mask 255 255 255 0 MTL 1500 MAC Address UU AA BE CC UU 04 DHCP Server Enabled Wireless Wireless Enabled SSID C00000 Channel D Encryption Mode None System Log The gateway will constantly log events and activities and provide the files for you to review You can click Refresh to renew the page or Clear Logs to clear all or certain log entries system Status gt System Log System log Boot DHCP Server Message NTR Client PPTP WPN Log Option ayvstem Event LIPHP Firewall Modem Cipenyvpn f E Select All Deselect All gave Option System Log Refresh Clear Logs Date a Content Time Traffic Statistics This page displays network traffic statistics for packets both received and transmitted through Ethernet ports and wireless connections ORing Industrial Networking Corp 59 ORing IMG W6121GT M12 User Manual System Status gt Traffic Statistics Traffic statistics Interface Receive Wired LAN 29009393 Bytes 4540 6 Packets 127554405 Bytes 1206456 Packets WAN U Bytes U Packets U Bytes U Packets WAN U Bytes U Packets U Bytes U Packets ies Gite eee 60050672 Bytes 1065573 Pack
38. ets U Bytes U Packets wireless 0 Bytes U Packets U Bytes U Packets T lL WAN Wireless Link List This page displays the Mac address of all wireless clients connected System Status gt Wireless Link List List of connected wireless clients Mac Rx Rx Tx TX Rssi TX Address Bytes Packets Bytes Packets Quality Bitrate ORing Industrial Networking Corp 60 ORing IMG W6121GT M12 User Manual Technical Specifications ORing M2M Model Physical Ports 1 8 pin M12 A coding Female connector 10 100 1000 Base T X Ports in M12 Auto MDI MDIX with PoE P D IMG W6121 3G M12 IMG W6121 4G M12 Cellular Interface Cellular Standard Band options GSM GPRS EGPRS EDGE WCDMA HSDPA GSM GPRS EGPRS EDGE WCDMA HSDPA HSUPA America US UMTS HSDPA HSUPA HSPA DC HSPA 800 850 1900 2100 MHz GSM GPRS EDGE 850 900 1800 1900 MHz Europe EU UMTS HSDPA HSUPA HSPA DC HSPA 900 2100 MHz GSM GPRS EDGE 900 1800 1900 MHz HSUPA LTE America US LTE 700 1700 2100 MHz UMTS HSDPA HSUPA HSPA DC HSPA 800 850 1900 2100 MHz GSM GPRS EDGE 850 900 1800 1900 MHz Europe EU LTE 800 900 1800 2100 2600 MHz UMTS HSDPA HSUPA HSPA DC HSPA 900 2100 MHz GSM GPRS EDGE 900 1800 1900 MHz Antenna Connector N type Female WLAN Feature Antenna Connector Radio Frequency Type Modulation Frequency Band Transmission Rate N type Female Wi Fi ANT x2 DS
39. figurations or return settings to previous status You can download the configuration file from the Web Note users using old versions of Internet Explorer may have to click on the warning on top of the browser and choose Download File E To help protect your security Internet Explorer blocked this site from downloading files to your comput r Click here for x EAN g S B j 7 options Download File re isis the Risk Information Bar Help ORina Indiuetrial ANY 44 alhin 2EC ORing Industrial Networking Corp 52 ORing IMG W6121GT M12 User Manual System Tools gt Save Restore Configurations cave Restore Contigurations cave Current configurations Save Restore previous saved configurations Restore Mode Web Restore Y Sms See Les Web Restore Restore factor default settings Restore Factor Default Settings Click to save existing configurations as a file for future usage You can restore configurations to previous status by installing a previous configuration file To do this choose Web Restore or Tftp Restore If you choose Web Restore you need to choose a file and click Web Restore If you selet Tftp Restore fill in a Tftp server IP address and the file name before clicking Tftp Restore Restore Factory Click to reset the gateway to the factory settings The gateway will Default Setting reboot to validate the default settings Miscellaneous This page enables you to run ping test
40. her authentication server on the network Available values include TKIP AES and TKIP AES mix WPA PSK uses TKIP encryption and WPA2 PSK uses AES Encryption Type encryption TKIP AES provides the most reliable security and is easiest to implement Radius Server IP Enter the IP address of the RADIUS server Radius Port Enter the RADIUS port default is 1812 Shared Secret Enter the RADIUS password or key When you set security type as 802 1x the following fields will appear to allow you to configure individual settings Security Options Security Type 802 1 N WEF Encryption Ed Bit Y Key Type ASCII 5 characters Y Default Key Index 1 Y KEY 1 KEYZ KEYS KEYS Radius server P 0 0 O 0 Radius Port 1812 shared Secret radius key WEP Encryption You can select 64 Bit or 128 Bit Available values include ASCII and Hex Key Type ASCII American Standard Code for Information Interchange is a code for Key Type representing English characters as numbers in the range from 0 to 127 Hex digits uses 0 9 to represent values zero to nine and characters A F to represent values ten to fifteen Default Key Index Select one of the keys to be the active key Key 1 to 4 Input up to four encryption keys Radius Server IP Enter the IP address of the RADIUS server ORing Industrial Networking Corp 22 ORing IMG W6121GT M12 User Manual Radius Port Enter the RADIUS port default is 1812 Shared Secret Ente
41. i AT A LE i1 DI 1 Wi Fi antenna connector ORing Industrial Networking Corp 3 ORing IMG W6121GT M12 User Manual Hardware Installation Before installing the device make sure you have all of the package contents available and a PC with Microsoft Internet Explorer 6 0 or later for using web based system management tools When installed outdoors make sure the connectors on the panel are facing down to prevent water intrusion Do not remove the water proof casing and avoid touching or moving the device when the antennas are transmitting or receiving When installing the device make sure to keep the radiating at a minimum distance of 20 cm 7 9 inches from all persons to minimize the potential for human contact during normal operation Do not operate the device near unshielded blasting caps or in an otherwise explosive environment unless the device has been modified for such use by qualified personnel The device can be fixed to a pole or the wall using the supplied mounting plate Make sure the connectors on the bottom panel are facing down when installing to prevent water intrusion Screw holes for attaching the plate to the unit T Wall mount Strap slots for pole mounting Mounting plate ORing Industrial Networking Corp 4 ORing IMG W6121GT M12 User Manual 3 1 Wall Mounting 250 0 220 0 Wall mount Measurements Unit mm Follow the steps below to install the device to the w
42. ifies the port to be logged remotely Default port is 514 E mail System Tools gt Even Warning Settings gt E mail eel Serer Senge SMTP Server T i Server Port 25 0 represents default E mail Address 1 E mail Address 2 E mail Address 3 E mail Address 4 optional S lilell Siete Warts Device Event Notification Hardware Reset Cold Start SMTP Mail Software Reset Warm Start SMTP Mail Login Failed WAN IP Address Changed Password Changed Redundant Power Changed Eth Link Status Changed SNMP Access Failed Wireless Client Associated Wireless Client SMITE Mail Disassociated Client Mode Associated SMTP Mail Client Mode Disassociated SMTP Mail Client Mode Roaming SMTP Mail Fault Event Notification Power 1 Fault Power 2 Fault POE Fault Ethi Link Down SMTP Server Enter a backup host to be used when the primary host is unavailable Specifies the port where MTA can be contacted via SMTP server ORing Industrial Networking Corp 55 IMG W6121GT M12 User Manual System Tools gt Even Warning Settings gt SNMP Settings SNMF Settings SNMP Agent o Enable Disable SNMP Trap Server 1 SNMP Trap Server 2 SNMP Trap Server 3 SNMP Trap Server 4 Community public E SysLocation i SysContact SNMP Event Types Device Event Notification Hardware Reset Cold Start SNMP Trap Software
43. king Corp 15 ORing IMG W6121GT M12 User Manual Gateway Name Enter the name of your gateway IP Address The IP address of the LAN The default value is 192 168 10 1 Subnet Mask The subnet mask of the LAN The default value is 255 255 255 0 LLDP Protocol LLDP is a vendor neutral protocol used by network devices for advertising their identity capabilities and neighbors on a LAN You can enable or disable LLDP protocol DHCP DHCP is anetwork protocol designed to allow devices connected to a network to communicate with each other using an IP address The connection works in a client server model in which DHCP clients request an IP address from a DHCP server The gateway comes with a built in DHCP Dynamic Host Control Protocol server which assigns an IP address to a computer DHCP client on the LAN automatically The gateway can also serve as a relay agent which Sunday will forward DHCP requests from DHCP clients to a DHCP server on the Internet The IP allocation provides one to one mapping of MAC address to IP address When a computer with a MAC address requesting an IP address from the gateway it will be assigned with the IP address according to the mapping You can choose one from the client list and add it to the mapping list Basic Setting gt DHCP gt DHCP Server Set DHCP Server DHCP Mode Built in DHCP Server Y DHCP Server Enabled Disabled starting IF 192 168 2292 Ending IP 192 166 2255 Lease
44. nation computer Configures the protocol to be filtered Enable Now Click Yes to enable the entry after adding it Shows the information of all IP filters Click Edit to edit the entry or Del to delete the entry MAC Filter This page enables you to deny or allow LAN computers to access the Internet based on their MAC addresses Networking Setting gt Firewall Setting gt MAC Filter MAC Filter settings MAC Filter Enable Disable Description Rule DROP MAC Address ex 00 11 24 aa 00 CC Enable Mow gt Yes No Add Cancel MAC filter list Description MAC Address Enabled Operations MAC Filter Enables or disables the MAC Filter Description Enter description for the entry Configures the rules to be applied to the MAC filter Available options include DROP ACCEPT and REJECT MAC filter list Shows the information of all MAC filters Click Edit to edit the entry or Del to delete the entry Custom Rules Custom firewall rules provide more granular access control beyond LAN isolation You can define a set of firewall rules that is evaluated for every request sent by a wireless user associated to that SSID Firewall rules are evaluated from top to bottom The first rule that matches is applied and subsequent rules are not evaluated If no rules match the default rule allow all traffic is applied ORing Industrial Networking Corp 37 ORing IMG W6121GT M12 User Manual Networking Setting
45. o Ethernet Flush Data Buffer After O ms DelimiterfHex 0 11 1 00 2 DU 3 DU 4 DU Mode Ethernet to Serial Flush Data Buffer After O ms DelimiteriHex 0 11 1 O 2 00 3 00 4 DU The TCP port the device uses to listen to connections and that Local TCP Port other devices must use to contact the device To avoid conflicts with well known TCP ports the default is set to 4000 A listen TCP port for IP Serial Lib commands from the host In Command Port order to prevent a TCP port conflict with other applications the user can set the Command port to another port if needed The received data will be queuing in the buffer until all the delimiters are matched When the buffer is full 4K Bytes or after Flush Data Buffer After Flush Data Buffer After times out the data will also be sent You can set the time from 0 to 65535 seconds For advanced data packing options you can specify delimiters for Serial to Ethernet and or Ethernet to Serial communications You can define Delimiter max 4 delimiters 00 FF Hex for each way The data will be hold until the delimiters are received or the option Flush Serial to Ethernet data buffer times out 0 means disable Factory default is 0 Service Mode Virtual COM Mode In Virtual COM mode the driver establishes a transparent connection between host and serial device by mapping the port of the serial server serial port to a local COM port on the host computer The Virtual COM mode
46. of bits used to indicate the end of a byte You can configure stop bits to be 1 or 1 5 2 If Stop Bits is 1 5 the Stop Bits stop bit is transferred for 150 of the normal time used to transfer one bit Both the computer and the peripheral device must be configured to transmit the same number of stop bits Chose the method of detecting errors in transmission Parity control bit modes include None Odd Even Mark and Space None means parity checking is not performed and the parity bit is not transmitted Odd means the number of mark bits in the data is counted and ay the parity bit is asserted or unasserted to obtain an odd number of mark bits Even means the number of mark bits in the data is counted and the parity bit is asserted or unasserted to obtain an even number of mark bits or XON to tell the computer to begin sending data again Force TX interval time is to specify the timeout when no data has been transmitted When the timeout is reached or TX buffer is full Force TX Interval Time 4K Bytes the queued data will be sent 0 means disable Factory default value is 0 Throughput This mode is optimized for the highest transmission Performance speed Latency This mode is optimized for the shortest response time ORing Industrial Networking Corp 24 ORing IMG W6121GT M12 User Manual Port Profile Serial Setting gt Port profile Fort Y Local TCP Port 4002 Command Port 40035 Mode s flal t
47. on Gateway Subnet Mask Metric Interface Operation WAN Y Add Telnet Setting Enable Disable Port 23 Password ORing Industrial Networking Corp 48 ORing IMG W6121GT M12 User Manual Current Routing Shows all routing information including static and dynamic routing if Table enabled Static Route Entry Fills in corresponding information to add new entries to the static routing tablet Choose Gateway Mode if you want PCs in the LAN to visit external network otherwise choose Router Mode RIPv1 amp v2 Choose Disable to disable dynamic routing or other options to configure the interfaces for dynamic routing Telnet Setting This option is only available when dynamic routing is enabled It allows you to make detailed configurations via simple comments cU Telnet 192 168 10 1 Command incomplete ello this is zebra version 4 94 opyright 1996 2082 Kunihiro Ishiguro APR6549 78 gt enable Turn on privileged mode command exit Exit current mode and down to previous list Print command list ping send echo messages quit Exit current mode and down to previous mode show Show running system information telnet Open a telnet connection traceroute Trace route to destination il 7 Switch ae 0 Switch Routing Topography ORing Industrial Networking Corp 49 ORing IMG W6121GT M12 User Manual Load Balance Rule Networking Setting gt Load Balance Rule gt Rule Setting Load B
48. openvpn website Routing Setting Networking Setting gt VPN Setting gt OpenVPN ClientRoute Common Mame Subnet IP Address Metmask Enable Mow Yes Mo Add Cancel Open PM Common Name Subnet IP Netmask Enabled Operations Common Name Enter a common name for you to identify the VPN Subnet IP Address Enter the subnet IP address for the VPN ORing Industrial Networking Corp 41 ORing IMG W6121GT M12 User Manual Netmaskk Enter the netmask IP address for the VPN Enable Now Check to enable the function PPTP VPN PPTP Point to Point Tunneling Protocol VPN allows PCs connected to the gateway through WAN ports to act as PCs in the same LAN WAN Link WAN Link PPTP VPN VPN Link a LAN Link Home PC Offic PC To create a PPTP connection to the gateway you must create a new network connection on your Windows PC by right clicking Network gt Property gt Create a new connection gt Connect to my work space VPN gt Use VPN to Internet and then enter the user name and password set in the page After setting up a new connection you can make configurations in the following page ORing Industrial Networking Corp 42 ORing IMG W6121GT M12 User Manual Networking Setting gt Vpn Setting gt PPTP Vpn PPIP Server settings PPTP Server Enable Disable server IP 192 168 2231 Clients IP 192 168 2 150 180 PPP Options require chap require mschap
49. r the RADIUS password or key Serial Setting Remote Management The remote management setting allows you access the serial port from a WAN network Serial Setting gt Remote management Set the Remote Management enable Ds tool to access from WAM cere Enable Disable Port External ACCESS Port Enable Disable Port Enable Disable Label Description Remote Management Enables or disables remote management function Enable to allow using of serial data port and control port through Port External Access WAN access Serial Configuration This page allows you to configure serial port parameters Serial Setting gt Serial Configuration Porti Port Alias Port Interface Rod Y Baud Rate 115200 Data Bits O Y Stop Bits 1 V Parity None Y Flow Control None T A eed ge Performance Throughput Latency ORing Industrial Networking Corp 23 ORing IMG W6121GT M12 User Manual Port Alias Enter the COM port number that modem is connected to Choose an interface for your serial device Available interfaces Interface include RS 232 Choose a baud rate in the range between 110 bps and 115200 Baud rate E DS Choose the number of data bits to transmit You can configure data bits to be 5 6 7 or 8 Data is transmitted as a Data Bits l l l l aa aa series of five six seven or eight bits five and six bit data formats are used rarely for specialized communications equipment Choose the number
50. r users the antenna type and its gain should be so chosen that the equivalent isotropically radiated power e i r p is not more than that permitted for successful communication Afin de r duire les interferences radio potentielles pour les autres utilisateurs le type d antenne et son gain doivent tre choisie que la puissance isotrope rayonn e quivalente PIRE est pas plus que celle premise pour une communication r ussie RF exposure warning The equipment complies with RF exposure limits set forth for an uncontrolled environment The antenna s used for this transmitter must not be co located or operating in conjunction with any other antenna or transmitter Avertissement d exposition RF L quipement est conforme aux limites d exposition aux RF tablies pour un incontr l s environnement L antenne s utilis e pour ce transmetteur ne doit pas tre co localis s ou fonctionner en conjonction avec toute autre antenne ou transmetteur ORing Industrial Networking Corp 64
51. rces Otherwise VPN clients can access the shared resources of only those computers directly connected to the local network of the device LZO Compression Enables or disables the LZO Compression Check the box will enable compression over VPN ORing Industrial Networking Corp 40 ORing IMG W6121GT M12 User Manual Keys Setting Select Auto to use preset certificates or Manual to use your certificates Please install openvpn client software to generate your certificates and paste them here For more information please visit openvpn website Open VPN Client Enables or disables the function of Open VPN client Server IP Host name Enter the Open VPN server IP address Tunnel Protocol Select UDP or TCP protocol depending on your needs TCP is more reliable than UDP but UDP performs better than TCP It is recommended to use UDP if the distance between VPN server and client is short otherwise use TCP Por The number eea RR Test Site Type a website address the field to use it to check if the connection is alive or lost Reconnection on Failure Check the box to enable the device to reconnect when the link fails LZO Compression Enables or disables the LZO Compression Check the box will enable compression over VPN Keys Setting Select Auto to use preset certificates or Manual to use your certificates Please install openvpn client software to generate your certificates and paste them here For more information please visit
52. s 1 TCP Client Mode In TCP Client mode the device can establish a TCP connection with a server by the method you set Startup or any character After the data has been transferred device can disconnect automatically from the server by using the TCP alive check time or Idle timeout settings ORing Industrial Networking Corp 27 ORing IMG W6121GT M12 User Manual Serial Setting gt Service Mode Porti Data Encryption Enable Disable Service Mode TCP Client Mode Y Destination Host 0 0 0 0 4002 Idle Timeout 0 U B5535 seconds Ale Check 40 U 65535 seconds Connect on Startup Any Character Destination Host Port 1 b522 2 boogdo S boodo 4 69939 Data Encryption Use SSL to encrypt data Destination Host Set the IP address of host and the port number of data port When serial port stops data transmission for a defined period of time Idle Timeout the connection will be closed and the port will Idle Timeout be freed and try to connect with other hosts 0 indicate disable this function Factory default value is 0 If Multilink is configured only the first host connection is effective for this setting The serial device will send TCP alive check package in each defined time interval Alive Check to remote host to check the Alive Check TCP connection If the TCP connection is not alive the connection will be closed and the port will be freed 0 indicate disable this function Factory default is 0 seri
53. shared Key o b 4 characters Available values include WPAPSK WPA2PSK and WPAPSK WPA2PSK mix WPAPSK and WPA2PSK will encrypt the link without additional RADIUS server only an Auth Mode access point and client station that supports WPA PSK is required For WPA WPA2 authentication is achieved via WPA RADIUS Server You need a RADIUS or other authentication server on the network Available values include TKIP AES and TKIP AES mix WPA PSK uses TKIP encryption and WPA2 PSK uses AES Encryption Type encryption TKIP AES provides the most reliable security and is easiest to implement Shared ic Enter a pass phrase in this field The value must be within 8 to ared Key 64 characters When you set security tyoe as WPA WPA2 Enterprise the following screen will appear to allow you to configure individual settings Security Options Security Type WPA PA Enterprise Y Auth Mode WEA o WPA WRAAWPAS mix Encryption Type TKIP AES TKIPJAES mix Radius Server IP 0 U iO iO Radius Port 1912 shared secret radius key Auth Mode Available values include WPAPSK WPA2PSK and ORing Industrial Networking Corp 21 ORing IMG W6121GT M12 User Manual WPAPSK WPA2PSK mix WPAPSK and WPA2PSK will encrypt the link without additional RADIUS server only an access point and client station that supports WPA PSK is required For WPA WPA2 authentication is achieved via WPA RADIUS Server You need a RADIUS or ot
54. siciciassssonsaceadadsiudayoaancssdelainboondediaadsd siwbencdonsarersdasminsewhaanusaderensen 9 4 3 Wireless Antenna eee eee eee eee 10 4 4 Celular ARS ee D 10 Management EL anse dona a A ee ee Re ee 11 5 1 Network Connection sise 11 52 CONU RO e e E E AE 12 KK ASIC 12 eT E E E E EA T A d 12 K 5 TT 12 L 15 D TT 16 DACP Chent IS e nes dents ennemie de it 18 MET AN a a ae a nt 18 SL ES LE AA a Ze 23 Komot M maremen a a da ee nee acts 23 Servite MOUE tes eee ate tan ee ee Ne dt ni 25 LCP SEV CE MOUE iri aan de dm anni 26 Ce Ti tt a a a a 0 HO ia 27 COP Ee MORS aa ee a ob do 28 DOS ee a 29 DS OCR nn da ee nn 30 322 Neiworkin SUTIN 2 ceed spe cate cind cane donner cas cape ee aE een nue 30 NYC ESS SSN oa as ia cn 30 DUO ATOS T 30 MAC Gi TTT 33 ORing Industrial Networking Corp 2 ORing TGAR 1062 2062 1662 Series User Manual KALS a ee Re a di 34 KTR ss CIA EEE 34 D nd E E A 35 OE9 AU D a a E o E E E E 35 Firewall SC CHING nc een iare saii E 36 ER E E E E E E A E 36 MAC PU T er E E A E E E A 37 ISL N aT 37 Ki PD R THT 38 DM DH 38 ROUES E ee nd ed om oi 41 PP AE ITE 42 IS k C n 43 eE OT 45 32 2 a sated hy A E E A E E ce eantercenepeneca N 45 ROBES RO a a a de 47 ROU UMS TOPOSTA DANS aan E associe aise ant onto 49 Load Balance RU a en 50 e ETOO oe E S S E E E 50 ERE e E a ye A A EE A E ouais 50 M M Rear ersa E E EE NE E EE EEEE 51 Peny Ae BT T KE SAC LR C onii g UE La TTT 52 I Re VI ie 53
55. ssociate with the VRID Configure the VRID on the router that owns the default gateway interface The other router in the VRID does not own the IP address associated with VRID but provides the backup path if the Master router becomes unavailable Virtual Router IP An IP address associated with the VRID from which other hosts can obtain network service The VRIP is managed by the VRRP instances belonging to a VRID The priority value used by the VRRP router when selecting the master virtual router Routing Protocol This page shows the information of the routing table You can configure static and dynamic routing settings in this page Networking Setting gt Routing Protocol gt Routing Setting Current Routing Table Destination Gateway Subnet Mask Metric Interface 192 168 2 0 0 0 0 0 259 299 299 0 U UL LAN 127 0 0 0 0 0 0 0 255 0 0 0 U lof LOOPBACK static Route Entry Destination Gateway Subnet Mask Metric Interface Operations Destination Gateway Subnet Mask Metric Interface Operation WAN Y Add Mode Gateway Y RIP R ve Disable Telnet Setting Enable Disable Port 23 Password Static Routing When RIPv1 amp v2 is Disabled the gateway will operate in static routing mode which means gateways forward packets using either route information from route table entries that you manually configure or the route information that is calculated using dynamic routing algorithms ORing Industrial Net
56. to IP rules Obtain DNS server Obtains a DNS server address from a DHCP server If you have address automatically chosen to obtain an IP address automatically this option will be selected accordingly Use the following DNS Specifies a DNS server address manually You can enter two Peer AP Peer AP SSID Enter the Enter the SSID of the AP you want to connect as a client of the AP you want to connect as a client Site Survey Click the button to browse available sites if you do not know the SSID A list of available sites will be displayed Security Options Select the security type used by the client you want to connect You can choose WEP which will encrypt data transmitted on the WLAN or WPA PSK WPA2 PSK which uses a pre shared key for authentication Use Modem 3G as Enable this option if you want to use modem 3G as a backup backup connection connection when main connection is lost Enter your account username and password in the corresponding fields Type a website address such as www google com in Ping Test Site to use it to check if the connection is alive or lost LAN This page allows you to configure the IP settings of the LAN for the gateway The LAN IP address is private to your internal network and is not visible to Internet Basic Setting gt LAN LAN Side settings Router Name IMECCOODA IP Address 192 169 22931 Subnet Mask 255 256 255 T LLOP Protocol Enable Disable ORing Industrial Networ
57. unction if you host services online such as FTP Web or game servers A public port must be defined for the virtual server on your gateway in order to redirect traffic to an internal LAN IP address and LAN port Any PC used as a virtual server must have a static or reserved IP address Networking Setting gt NAT Setting gt Virtual Server Virtual server settings Virtual Server Enable Disable Description Public IF Al Specify Fublic Fort Protocol R RG UDH Bath Local IP Local Port Enable Mow Yes Mo Add Cancel Virtual server list Public Public Local IP Port Enabled Ops Description Protocol Local IP Virtual Server Select Enabled or Disabled to activate or deactivate virtual server Description Enter the description of the entry Acceptable characters are 0 9 a z and A Z A null value is allowed Enter a public IP allowed to access the virtual service If not lni specified choose All Public Port The port number to be used to access the virtual service on the WAN Wide Area Network Enables the virtual server entry after adding it Virtual server list Click Edit to edit the virtual service entry and Del to delete the entry ORing Industrial Networking Corp 34 ORing IMG W6121GT M12 User Manual DMZ DMZ Demilitarized Zone allows a computer to be exposed to the Internet without passing through the security settings and therefore is unsecured This feature is useful for special
58. which will send out ping packets to test if a computer is on the Internet or if the WAN connection is OK Enter a domain name or IP address in the destination box and click Ping to test System Tools gt Miscellaneous Miscellaneous utilities Ping Test Destination Ping Ping Test Result ORing Industrial Networking Corp 53 ORing IMG W6121GT M12 User Manual Event Warning When an error occurs the gateway will notify you through system log e mail SNMP and relay System Log System Tools gt Even Warning Settings gt System Log Syslog Server Settings syslog server IF oyslog Server Port D represents default Syslog Event Types Device Event Notification Hardware Reset Cold Start Software Reset Warm Start Login Failed WAN IP Address Changed Password Changed Redundant Power Changed Eth Link Status Changed SNMP Access Failed Wireless Client Associated Wireless Client Disassociated Client Mode Associated Client Mode Disassociated Client Mode Roaming Fault Event Notification Power 1 Fault Power Fault POE Fault Eth1 Link Down Syslog Syslog Syslog Syslog Syslog Syslog Syslog Syslog Syslog Syslog Syslog Syslog Syslog Syslog Server IP Enter the IP address of a remote server if you want the logs to be stored remotely Leave it blank will disable remote syslog ORing Industrial Networking Corp 54 ORing IMG W6121GT M12 User Manual Syslog Server Port Spec
59. working Corp 47 ORing IMG W6121GT M12 User Manual Networking Setting gt Routing Protocol gt Routing Setting Current Routing Table Destination Gateway Subnet Mask Metric Interface 192 168 2 0 0 0 0 0 255 255 255 0 U brOfLAn 127 0 0 0 0 0 0 0 255 0 0 0 U lof LOOPBACK Static Route Entry Destination Gateway Subnet Mask Metric Interface Operations Commit Subnet Mask Metric Interface Operation WAN Y Add RIPyT amp v2 Disable Y Telnet Setting Enable Disable Port 23 Password Dynamic Routing Dynamic routing lets routing tables in gateways change as the routes change If the best path to a destination cannot be used dynamic routing protocols change routing tables when necessary to keep your network traffic moving Dynamic routing protocols include RIP OSPF and BGP however the device only supports RIP Routing Information Protocol Do not choose Disable in the RIPv1 amp v2 list if you want to enable Dynamic Routing After clicking Apply more information will be displayed in Current Routing Table Networking Setting gt Routing Protocol gt Routing Setting Current Routing Table Destination Gateway Subnet Mask Metric Interface 192 168 2 0 0 0 0 0 29 12002000 U brOjLAn 127 0 0 0 0 0 0 0 255 0 0 0 U lof LOOPBACK static Route Entry Destination Gateway Subnet Mask Metric Interface Operations 192 168 11 0 0 0 0 0 255 255 755 0 1 WAN Commit Delete Destinati