M3e User Manual

image

Contents

1. gez 27 30 MDG M3e Fog Generator WARRANTY When installed and operated as recommended MDG Fog Generators Ltd guarantees that this product will remain free of defects in parts and labour for a period of two 2 years from the moment it is delivered This warranty does not apply if the product has been modified without our written authorization or repaired without a written authorization from MDG or one of its authorized service centres or if it is used under conditions for which it has not been designed or if any other fluid than the MDG Neutral Fog Fluids has been used MDG Fog Generators Ltd is not responsible for any damages resulting from a faulty installation or from abusive use of the product If any device is found unsatisfactory under the terms of this warranty MDG Fog Generators Ltd will repair or replace it free of all charges except transportation costs This warranty applies only to the product itself and MDG Fog Generators Ltd declines responsibility for any losses costs or damages resulting from its use MDG Fog Generators Ltd shall not be liable for consequential damage in case of any failure to meet the conditions of any warranty or shipping schedule nor will claims for labour loss of profits repairs or other expenses incidental to replacement be allowed The repair or replacement of the product by MDG Fog Generators Ltd shall constitute fulfilment of all obligations to the purchaser No other
2. 20 psi Fluid type MDG Neutral Fog Fluid ONLY M S D S available on request Fluid reservoir 2 5 0 66 US gal bottle Gas type Industrial Grade CO or N Gas pressure input 4 15 bar 60 psi max Gas consumption 1 6 kg 3 53 Ib per hour at 2 76 bar 40 psi 0 96 kg 2 12 Ib per hour at 1 38 bar 20 psi Automatic Purging System Standard feature Warm up time 8 minutes Operating voltage 100 250 VAC 50 60Hz 1 phase Ground Earth connection REQUIRED Power consumption 715 W Control signal Manual 4 buttons keyboard LCD USB diagnostic amp Bootload DMX RDM Protocol Operating temperature 0 C to 60 C 32 FF to 140 F Operating humidity 90 9 relative humidity 50 C 122 F non condensing Storage temperature 40 C 40 F to 140 C 284 F Storage humidity 80 relative humidity 70 C 158 F Approval CE CSA and UL pending Dimensions 30 cm 12 H x 18 cm 7 W x 61 cm 247 L Weight 15 6 kg 35 Ib Shipping Weight Operating Guide Rev A a 20 4 kg 45 Ib without flight case 29 1 kg 64 Ib with flight case 25 30 MDG M3e Fog Generator DIMENSIONS Operating Guide Rev A a 26 30 Operating Guide Rev A a M3e Fog Generator 989 v6
3. MDG M3e Fog Generator NOTES Operating Guide Rev A a 30 30
4. Operating Guide M3e Fog Generator Revision A a July 2013 MDG Fog Generators Ltd CE NC TS Les G n rateurs de Brouillard MDG Lt e MDG Fog Generators Ltd QUE no 10301 avenue Pelletier Montr al Qu bec Canada H1H 3R2 Tel 514 272 6040 800 663 3020 Fax 514 722 3229 www mdgfog com e mail info mdgfog com MDG M3e Fog Generator Intentionally left blank Operating Guide Rev A a 2 30 NDG TABLE OF CONTENT Section TABLE OF CONTENT OPERATING GUIDE How to read this operating guide Qualified Personnel Need a little Help BASIC DESCRIPTION Installing the M3e Working with the M3e The Keyboard Menu Tree Operating instructions DMX Control Bootloader RDM Control FOG FLUID FILLING THE FLUID RESERVOIR Troubleshooting ACCESSORIES Flight Case Portability option TECHNICAL SPECIFICATIONS DIMENSIONS Warranty Declaration of conformity Notes Operating Guide Rev A a M3e Fog Generator v 9 Q D O o wan wn A A KR W 3 30 MDG M3e Fog Generator OPERATING GUIDE Congratulations You are now in possession of a MDG M3e Fog Generator We hope this M3e Fog Generator will bring you long hours of satisfaction Please read the following instructions carefully and completely before filling your Fog Generator with the MDG Neutral Fog Fluid and turning it on HOW TO READ THIS OPERATING GUIDE WARNING and CAUTION are used throughout this manual to forewarn of possible danger to the users if
5. gt FOG gt OFF the M3e will stop producing haze and initiate the automatic purging cycle WARNING AN Never power off a generator while it is producing fog See the shut down procedure Operating Guide Rev A a 14 30 MDG M3e Fog Generator Shut down procedure Never shut down the MDG M3e while making Fog Power off the generator observing the following sequence e Turn off the fog emission e Wait 30 seconds for the APS cycle to complete e Switch the generator UNIT OFF mode CONTROL UNIT OFF e Power off the MDG M3e by switching off the MAIN POWER SWITCH Switching directly the generator in UNIT OFF mode by DMX RDM will yield the same result as above Wait for all the cycles to complete before powering off the generator FAIL State FAIL state mode is initiated if any critical error occurs In this state the MDG M3e is off awaiting an action from the user A critical error is always displayed in the Status Menu STATUS gt ERROR as well as the five 5 last critical errors STATUS LAST ERR e ERROR HEATER LAST ERR CODE 6 This error will occur if the temperature of the heating module is not increasing with the proper thermal ramp This is generally due to a heater cartridge s problem Shut down the generator and restart it Check the heating process with the value of the Status STATUS STATE xx HEAT If the percent is not increasing the heater cartr
6. 0 0 255 100 FOG OUTPUT from minimal to maximal e Channel 3 0 0 lt FOG OFF lt 128 50 128 50 lt FOGON lt 255 100 These channels have the same behaviour that the menus of the local interface see Operating instructions paragraph Operating Guide Rev A a 17 30 MDG M3e Fog Generator BOOTLOADER The MDG M3e uses a BootLoader also called boot manager This program is a firmware software embedded in a hardware device located into the non volatile memory of the microcontroller unit MCU that allows in circuit reprogramming of the device using its USB communication port Contact the MDG Service to have the last package firmware upgrade for the MDG M3e To upgrade the firmware you will need e a computer running under Windows with a USB 2 0 connector e special driver for the USB included in the package e astandard USB 2 0 cable A to B Male Male type RDM CONTROL The MDG Me can be controlled via a RDM ANSI E1 20 protocol an intelligent bi directional communication utilizing the DMX512 data link RDM allows a console or other controlling device to discover and then configure monitor and manage intermediate and end devices connected through a DMX512 network RDM provides for intelligent control of devices on a DMX512 network which has not been previously available outside of proprietary networks RDM Control has the same functionalities than the DMX Control see DMX Control with bi directional
7. guarantees or warranties expressed or implied are made by MDG Fog Generators Ltd in connection with its products This warranty is non transferable and applies to the original purchaser only To obtain satisfaction under the terms of this warranty contact your local sales office and we will be pleased to help you Operating Guide Rev A a 28 30 MDG M3e Fog Generator DECLARATION OF CONFORMITY C EC DECLARATION OF CONFORMITY According to IEC ISO 17050 MDG Fog Generators Ltd 10301 ave Pelletier Montreal OC Canada H1H 3R2 declare under our sole responsibility that the product including options or accessories Fog Generators models MAX 3000 APS MAX 5000 APS and MAX 5000 APS H O ATMOSPHERE APS and ATMOSPHERE APS H O ICE FOG Q and ICE FOG Compack MM MINI SINGLE SINGLE and DUAL to which this declaration relates is in conformity with the following standards IEC 60335 1 2001 Fourth Edition incl Corr 1 2002 A1 2004 A2 2006 Household and similar electrical appliancess Safety Part 1 September 2006 CISPR 22 2008 09 EN 55022 Class B IEC 61000 6 1 2005 EN61000 6 1 2007 EMC Part 6 1 FCC PART 15 Subpart B class B By conformance with the standards referenced the product follows the provisions of the directives listed below 2006 95 EC Low Voltage Directive 2004 108 EC EMC Directive AD att Martin MICHAUD President August 17 2012 Montreal Canada Operating Guide Rev A a 29 30
8. item of this list e f the selected menu is a data input menu keeping this key pressed will decrease the value more rapidly e In a data input menu when the value reaches its minimum value the program continues with the maximum value Up moves the selection to the previous menu or increase a data value e f the item is the first of a menu the program moves the selection to the last item of that menu e f the selected menu is a data input menu keeping this key pressed will increase the value more rapidly e In a data input menu when the value reaches its maximum value the program continues with the minimum value Mode moves the last selection to the upper level e This key has no effect in the first level e In a data input menu pressing this key permit to exit the menu without changing any value escape Enter confirms a selection or data value e This key has the same effect that the key gt when scrolling through the menus e In a toggle menu this key confirms the selection and moves the cursor back to the upper level menu e In a data input menu this key confirms the value of the data and moves the cursor back to the upper level menu Operating Guide Rev A a 10 30 MDG M3e Fog Generator MENU TREE The menu is divided in four 4 main menus e Status Menu summarizes all the state of the fog generator None of its sub menus can be modified e Control Menu allows the user to control locally the MD
9. precautions are not observed As is customary in military and some commercial manuals the precautions will always precede the steps to which it refers so that the users will be aware of any potential danger before performing the task WARNING and CAUTION labels are key equipment parts Do not remove change or cover these labels If the labels are not readable contact MDG FOG GENERATORS LTD BOLD TEXT Contains important information cautionary steps and warnings that should be read and understood prior to installing the unit BOLD and ITALIC TEXT pertains to product names and trademarks proprietary names and products made by MDG FOG GENERATORS LTD Please read the following instructions carefully and completely before installing pressurizing and turning on the Fog Generator QUALIFIED PERSONNEL MDG Fog Generators Ltd systems will perform as designed but are to be installed operated and serviced by trained personnel Installation operation and servicing of this equipment requires trained personnel with technical skills in electrical theory and fluid dynamics This manual is not a substitute for qualified technicians or local authorities on electricity gas fluid or engineering and therefore does not supersede amend or void local safety installation practices Please refer to local authorities for further information Operating Guide Rev A a 4 30 MDG M3e Fog Generator NEED A LITTLE HELP At MDG we try our best to p
10. G M3e All its sub menus can be set as long as the generator is not in DMX RDM mode e Interface Menu allows the user to define or verify the communication via DMX RDM e Setting Menu summarizes general configuration of the generator The menu is refreshed every second Items displayed with a s character are state messages or parameters updated by the program The user cannot modify them TEN INTERF C A 02 00 COMM AUTO be modified by user X DEU LABEL tg 200 DEW ID Sncdedd 32 Items displayed with a gt character are control parameters The user within specific ranges or choices can MODIFY them IHTERFAC 06i AZ S LOM AUTO This menu can be DEM LABEL Melder DEU ID 888464432 Operating Guide Rev A a 11 30 M3e Fog Generator The tree menu architecture is explained below Items highlighted in blue are state menu I and those highlighted in yellow are control menu 8 STATUS Status menu UNIT OFF xx HEAT PURGE READY FOG ON FAIL Operating Guide Rev A a Status State the generator is off the generator is heating but not ready the generator is purging the heating module the generator is generator is ready to produce fog the generator is producing Fog the generator is off due to a failure see diagnostic Error message when State FAIL see diagnostic Temperature status heating module temperature too low temperature within specific
11. Probable Causes and Suggested Actions e ERROR PCB HIGH e Stop the generator for few minutes if it is possible e Try to change the position of the generator to a cooler location Please contact MDG Service if this problem persists e ERROR WD RESET e Restart the generator Please contact MDG Service if this problem persists Operating Guide Rev A a 23 30 MDG M3e Fog Generator ACCESSORIES FLIGHT CASE Whether by plane train or automobile make sure your fog generator travels safe Our sturdy flight cases have high quality padding to make the journey easier on your generator with special compartments for accessories like cable extensions and remote control timers PORTABILITY OPTION The portability option stores the gas canister securely underneath your generator Special technology allows the canister to operate horizontally without the gas line freezing Just pick up your machine and go no more dragging around the canister and no more worrying about it tipping over Operating Guide Rev A a 24 30 MDG M3e Fog Generator TECHNICAL SPECIFICATIONS Series MAX Series Total Running Time 1 3 hours at 2 76 bar 40 psi 2 5 hours at 1 38 bar 20 psi Fog colour Pure white Particle size 0 5 to 0 7 microns Fluid consumption 1 9 53 1 oz 0 475 US gal per hour at 2 76 bar 40 psi 1 0 I 29 5 oz 0 264 US gal per hour at 1 38 bar
12. You cannot control the generator locally if you are in DMX mode and vice versa e f you are in DMX mode e Verify the cable e Verify the DMX Start address and the patch Operating Guide Rev A a 21 30 NDG M3e Fog Generator Symptoms Probable Causes and Suggested Actions STATE FAIL VERIFY THE ERROR MESSAGES e ERROR P LOW e Open the gas bottle e Verify the set pressure on the regulator 60 psi 4 1 bar or 410 kPa e Verify the gas line e Verify the reading of the pressure transducer STATUS PRESSURE ERROR P HIGH e Verify the reading of the pressure transducer STATUS PRESSURE e You may have a solenoid valve malfunction Restart the generator Please contact MDG Service if this problem persists ERROR HEATER e This is a heating timeout due to a cartridge heater problem e Restart the generator and check the heating status STATUS STATE xx HEAT If the heating value is not progressing there may be various issues Contact MDG Service ERROR T HIGH e Restart the generator This is generally due to an electronic problem Please contact MDG Service if this problem persists ERROR T SAF e Restart the generator This is generally due to an electronic or sensor problem Please contact MDG Service if this problem persists e Operating Guide Rev A a 22 30 MDG M3e Fog Generator Symptoms
13. art of the MDG M3e is an electronic assembly that keeps the heat exchanger at a very stable temperature with three different types of fail safe systems Those three types of electronic fail safe systems are designed to protect against over and under heating conditions and against component failure When an overheating condition is detected or if the internal temperature of the generator reaches 60 C 140 F a safety circuit is triggered This circuit removes the power to the heating elements preventing hazardous conditions When an under heating condition occurs the generator will stop producing fog until the temperature of the heating module is back within parameters A fourth safety system consists of a pressure relief valve which limits the working pressure and protects against over pressure The temperature of the heat exchanger is maintained within a narrow margin If an error occurs see FAIL State the Fog Generator will automatically shut down When one of the safety systems is activated the Fail state will be displayed on the LCD in the Status Menu Check the FAIL State and Troubleshooting paragraphs for diagnostics then shut down the main power switch wait 30 seconds and then switch the generator back on If the failure persists send your generator back to an authorized service center for verification When Fog On mode is activated DMX or Control Menu the MDG M3e Generator will produce fog for as long as the ready level
14. ations ready temperature too high Current reservoir pressure Temperature of the board see Units Total Run Time in decimal hours Total Fog Time in decimal hours Code for the Last five 5 errors See Fail State paragraph Control menu Unit toggle the generator is off the generator is on Fog toggle the fog is off the fog is on Fog operating pressure see Units 12 30 INTERFACE COMM BE AUTO LOCAL DMX DEV LABEL yyyyy DEV ID yyyyyy DMX ADDR yyy 1 UNIT yyy 2 OUTPUT yyy 3 FOG yyy SETTINGS UNITS PSI C KPA C BARPC PSUF VERSION XXX FIRMWARE X XX Operating Guide Rev A a M3e Fog Generator Network DMX RDM Menu Communication toggle the generator is controlled by DMX RDM if a signal is present or locally if there is no signal the generator is controlled by the keyboard ONLY the generator is controlled by DMX RDM ONLY RDM Device Name RDM Device ID DMX Address 1 to 510 Network DMX RDM Channel 1 value OFF lt 50 128 lt ON Channel 2 value 0 0 to 100 255 Channel 3 value OFF lt 50 128 lt ON Settings menu Units toggle pressure in psi temperature in Celsius pressure in kPa temperature in Celsius pressure in bar temperature in Celsius pressure in psi temperature in Fahrenheit Model Version Program Firmware 13 30 MDG M3e Fog Generator OPERATING INSTRUCTIONS The MDG M3e Fog Generator can be controlled either lo
15. cally with the keyboard via DMX see DMX control and RDM Control This paragraph focuses on local control Starting Procedures When powering up the generator the control program configures the Input Output and loads the configuration parameters saved in the EEPROM memory At this point the MDG M3e switches to stand by mode and most of the electronic controls are off When the generator is manually switched to UNIT ON mode CONTROL gt UNIT gt ON the program starts the heating cycle STATUS STATE HEAT which will last approximately 7 to 8 minutes When the temperature reaches READY level STATUS STATE READY the Automatic Purging System APS will be initiated STATUS STATE PURGING After the first purging cycle is completed approx time 30 sec the generator is ready to produce fog Fog Production When the generator is manually switched to FOG ON mode CONTROL gt FOG gt ON the M3e will start producing fog The amount of the fog emission can be controlled by adjusting the pressure CONTROL gt PRESSURE gt XX The MDG M3e will produce fog as long as the control parameters are within specifications and the fog fluid reservoir filled If a critical problem occurs the program shuts down automatically the fog generator and displays an error message in the State Menu see Fail State When the generator is manually switched to FOG OFF mode CONTROL
16. functions allowing the user to read or write specific functions Operating Guide Rev A a 18 30 MDG M3e Fog Generator The RDM supported parameters implemented in the MDG M3e Fog Generator are summarized in the following table RDM Parameter ID s Value nr Pane Comments DISC_UNIQUE_BRANCH 0x0001 DISC MUTE 0x0002 DISC UN MUTE 0x0003 QUEUED_MESSAGE Ox0020 v STATUS MESSAGES 0x0030 v SUPPORTED PARAMETERS 0x0050 v PARAMETER DESCRIPTION 0x0051 v DEVICE INFO 0x0060 v PRODUCT DETAIL ID LIST 0x0070 v DEVICE MODEL DESCRIPTION 0x0080 v White Mineral oil hazer MANUFACTURER_LABEL 0x0081 v MDG Fog Generators Ltd DEVICE_LABEL 0x0082 v v SOFTWARE VERSION LABEL Ox00C0 v DMX PERSONALITY 0x00E0 v v 1 DMX PERSONALITY DESCRIPTION 0x00E1 v DMX START ADDRESS 0x00F0 v v 1 to 510 SLOT INFO 0x0120 v SLOT DESCRIPTION 0x0121 v DEFAULT_SLOT_VALUE 0x0122 v IDENTIFY DEVICE 0x1000 v v LCD flashes MDG GENERATOR STATE 0x8002 S ASCII text Up to 20 characters Table 1 RDM Supported Parameters Operating Guide Rev A a 19 30 MDG M3e Fog Generator FOG FLUID Operate the M3e Fog generator only with the MDG Neutral Fog Fluid Make sure that no other liquids or particles are mixed or added to the MDG Fog Fluid The MDG Neutral Fog Fluid produces a pure white non toxic fog MDG Neutral Fog Fluid is available at authorized MDG di
17. gle or double stage regulator The gas inlet is an Oxygen Adaptor 9 16 18 R H Connect the data wiring Male XLR 5 connector for DMX RDM if you are using a DMX or RDM controller Connect the power cord 100 250 VAC 50 60 Hz 715W Open the gas bottle and set the pressure between 50 and 60 psi 3 5 and 4 1 bar or 350 and 410 kPa Operating Guide Rev A a 8 30 MDG M3e Fog Generator WORKING WITH THE M3e The MDG M3e Fog Generator is quite easy to operate and requires no preventive maintenance Switch On the power The MDG M3e will display during four 4 seconds the following message M3e by MDG Fog Generators Testing BootLoad These four seconds allow you to connect the generator to your PC via a USB cable to update the firmware of the control board see BootLoader for further details Then the MDG M3e will display during one 1 seconds the following message M3e by MDG Fog Generators Ltd V x xx F y yyy where x xx is the version of your generator and y yyy is the firmware of the program The program will load the configuration parameters saved in the EEPROM memory Finally the screen will display the menu Operating Guide Rev A a 9 30 MDG M3e Fog Generator THE KEYBOARD The user can scroll in the menu by using the buttons of the keyboard Down moves the selection to the next menu or decrease a data value e When at the end of a list the program moves back to the first
18. idges have failed e ERROR P LOW LAST ERR CODE 7 This error will occur if the generator is unable to reach the operating pressure within a fixed time interval This may be due to a leaking gas line between the gas bottle and the generator a closed or empty gas bottle a ball valve closed on the gas line or a problem with the pressure transducer e ERROR P HIGH LAST ERR CODE 8 This error will occur if the pressure is too high for a specific regime while the gas flow inlet is fully closed This may be due to a solenoid valve malfunction electronic or physical blockage a problem with the pressure transducer or the heating module partially clogged Operating Guide Rev A a 15 30 MDG M3e Fog Generator e ERROR T HIGH LAST ERR CODE 4 This error will occur if the temperature of the heating module is too high This is generally due to an electronic problem Shut down the generator and restart it e ERROR T SAF LAST ERR CODE 5 This error will occur if abnormal temperature difference between the two sensors of the heating module is detected This is generally due to an electronic or a sensor problem Shut down the generator and restart it e ERROR PCB HIGH LAST ERR CODE D This error will occur when the internal temperature of the generator is too high This may happen if the external temperature is high Move the generator in the shade or to a cooler location Shut down wait few minutes and then resta
19. is reached temperature and all other control parameters are within specifications When Fog On mode is deactivated the APS cycle is automatically initiated to clear the heating module Never remove the power to a generator while it is producing fog See the Shut down procedure WARNING e When not in use ALWAYS switch off the power switch located on the back panel and disconnect both gas and AC line e Never install above people e This M3e Fog Generator must be installed in an upright position on a stable and leveled surface e Use in a well ventilated area e Do not operate at less than 2 meters 6 5 ft from people Operating Guide Rev A a 6 30 MDG M3e Fog Generator Fog fluid reservoir Handle VAC Input 100 250 VAC 50 60 Hz Fog output nozzle LCD USB Connector Keyboard MAIN POWER XLR 5 DMX Switch RDM Connector CO or No Gas input 50 60 psi Operating Guide Rev A a 7 30 MDG M3e Fog Generator INSTALLING THE M3e Exercise caution when selecting the location to install or use this equipment e Install the MDG M3e away from rain wind heavy dust or any harsh environment situations e Ensure available space for all electrical cable and gas tubing runs e The MDG Me requires 2 m 6 56 ft of clearance to the front Fill the reservoir with MDG Neutral Fog Fluid see FILLING THE FLUID RESERVOIR paragraph Connect the gas inlet to a gas bottle equipped with a sin
20. rovide you with complete information for our products Despite our best efforts sometimes a little more is required due to the specifics of your project and installation We re looking forward to go that extra mile for you Contact us By Phone By Fax By e mail On the Web By Mail 1 800 663 3020 1 514 272 6040 1 514 722 3229 info mdgfog com www mdgfog com The QR code on the control panel is linked to the documentation eles na of the M3e from our web site Do not hesitate to follow the URL just click on the QR Code MDG Fog Generators Ltd 10301 Avenue Pelletier Montr al QC H1H 3R2 Canada Please note that our business hours are from 08h30 to 12h00 and from 12h30 to 16h30 8 30AM to 12 00PM and 12 30PM 4 30PM Eastern GMT 5 Operating Guide Rev A a 57 30 MDG M3e Fog Generator BASIC DESCRIPTION The M3e Fog Generator was designed with safety and reliability in mind It is capable of generating pure white non toxic fog for as long as you have fluid 100 duty cycle This generator is also equipped as a standard feature with the Automatic Purging System APS This system purges the heating module after the first heating cycle and after every emission of fog preventing residual build up and clogging The M3e is variable output Fog Generator capable of generating large volumes of very dense fog in a short period of time It is one of the quietest units on the market At the he
21. rt the generator e ERROR WD RST LAST ERR CODE E This error will occur if the watchdog software safety resets the generator This is generally due to software error an interference or chip problem Shut down the generator and restart it Please contact an Authorized Service Center if any problem persists Operating Guide Rev A a 16 30 MDG M3e Fog Generator DMX CONTROL The MDG Me can be controlled via a DMX512 A USITT standard protocol WARNING Activating the DMX mode INTERFACE gt MODE DMX controls the MDG MBe only by DMX signal If the DMX wire is unplugged or DMX signal is lost the generator initiates an automatic shutdown procedure Activating the AUTO mode INTERFACE MODE AUTO controls MDG MBe by DMX only if there is a signal If the DMX wire is unplugged or DMX signal is lost the generator keeps the last DMX values WARNING In AUTO Mode DMX commands always take precedence over Local commands The MDG Me provides a simple way to check if there is DMX signal STATUS B42 89 86 STATUS 4389209 STATE L MIT OFF re STATUS 7404 09 51 STATUS 5704 AZ 52 FSTATE UHN OFF ESTATE UHIT OFF i ST The user can change the DMX Start Address in the Interface Menu DMX Add and choose any value between 1 and 510 512 last DMX channel The generator uses three 3 DMX channels e Channel 1 0 0 lt UNIT OFF lt 128 50 lt UNIT ON lt 255 100 e Channel 2
22. stributors or dealers Available in 4 I 1 US gallon 5 Europe Only 20 5 3 US gallon 205 1 55 US gallon and 1000 I 264 US gallon FILLING THE FLUID RESERVOIR CAUTION DISCONNECT UNIT BEFORE ADDING FOG FLUID To fill the fluid reservoir unscrew the brass cap and pour the MDG Neutral Fog Fluid until it reaches the inside bottom of the opening Avoid overfilling screw back the brass cap and make sure it is tightened Operating Guide Rev A a 20 30 NDG TROUBLESHOOTING M3e Fog Generator Contact MDG if symptoms are not listed or if the provided solutions fail to resolve the issue Table 2 Symptoms and Solutions Symptoms Probable Causes and Suggested Actions The fog generator does not switch on e Verify that AC power cord is properly connected on both ends e Check the fuse or the breakers of your VAC entry The wattage of the generator is around 715 W e Verify the AC voltage on the power cord 100 250 VAC The generator does not produce fog e Verify that the Unit is ON CONTROL gt UNIT ON e Verify that the UNIT is READY STATUS STATE READY The generator requires approximately seven to eight 7 to 8 minutes to be ready While the heating module is warming up the HEAT must vary e Verify that the Unit is not in a FAIL state STATUS STATE FAIL If Yes check the symptoms below e Verify the communication mode INTERFACE gt MODE