1. CROW ELECTRONIC ENGINEERING LTD FW KP WIRELESS KEVPAD o 18 2 82 x 49 5 60 Fe INSTALLATION INSTRUCTIONS amp USER MANUAL P N 7101618 Rev B ME YS The FW KP is a wireless remote control keypad for POWERWAVE amp RUNNER security and home automation control panels The FW KP enables easy programming arming and disarming of the control panel It also allows to control devices from anywhere in the home or office using keypad commands FEATURES e Designed to comply with European Standards e Easy programming e User friendly operation e Hand held use and wall mounting e Back light illumination e Visual LED s indications e Audible signals confirm user commands e Up to 300 m range in open space e FSK unique technology e Keypads copy via smart EEPROM e Upto 5 year lithium battery life e Full Supervision MAKING YOUR FW KP WORKING WITH A WIRELESS CONTROL PANEL 1 INSTALL THE FW RCV ENROLL REQUIRED OPERATION RADIO SIGNAL ARM DISARM STAY CONTROL SET RADIO PANIC ALARM TO AUDIBLE OR SILENT ACTIVATE OUTPUT BY CHANNEL PANIC IF REQUIRED ACTIVATE OUTPUT BY RADIO CHANEL IF REQUIRED SET PENDANT CHIRPS FOR ARM DISARM PARTITION A AND PARTITION B IF REQUIRED N OF gr po ENROLLING RADIO CHANNELS In order to load a radio command on the panel press the appropriate address number e g P614E fo
2. Get into the address left column below and then proceed with enrolling procedure Enroll Press J Led Control panel enroll address indication pws 7 PRoG 611 618 ENTER ARM ob PWRITX CODE aRM ink RUNNER PRoG C 187 ENTER 24 400 O ENTER Button FW 64 PROG 55077 ENTER 24 100 gt ENTER pws PROG 611 618 ENTER DISARM lg PWRITX Button CODE DISARM blink RUNNER 7 PROG 18 ENTER 94 499 C7 ENTER FW 64 PROG 550777 ENTER 24 100 C7 ENTER pws 7 PROG 611 6187 ENTER ODi PWR TX STAY Button CODE C7 stay bink RUNNER O PROGC 187 ENTER 24 100 C77 ENTER FW 64 7 prog 550777 ENTER 241 100 77 ENTER pws PROGC 611 618 ENTER CONTROL op PWRITX B tion CO DE C CONTROL blink RUNNER 7 PROGT 1877 ENTER 94 499 C7 ENTER FW 64 7 PROG 550777 ENTER 241 100 77 ENTER pws proc 611 618 77 ENTER G PWRITX PANIC 183 PRESS 18 3FOR2 l ik RUNNER proc 187 CENTER 24 100 C7 ENTER seconds FW 64 7 PROG T 550777 ENTER 241 100 77 ENTER HOW TO USE THE PLUG IN DATA TRANSFER MODULE DTU Plug the DTU module CROW P N 0060330 to the black socket located at the back of the FW KP Read from DTU module Z PROGTINSTALLER CODE amp ENTER 7 COPY T 9 ENTER Write to DTU module Z PROGTINSTALLER CODE EXTER COPY T 197 ENTER NOTE When the SWITC
3. supersede all previous issues in circulation prior to December 2005 7101618 A
4. H is not in WRITE position the data in the DTU can not be written over HOW TO RESTORE ALL TO FACTORY DEFAULTS Remove the lithium battery and insert the battery again within 30sec PROG T INSTALLER CODE 7 T CLEAR amp 9 Note Press CLEAR amp 9 until the 3 panel indication LED s are blinking HOW TO INSTALL THE FW KP HOW TO REPLACE BATTERY CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS The battery must be replaced by 3 6V Lithium Battery Size 1 2AA Models as XL O50F ENERGY LS14250 SAFT TECHNICAL SPECIFICATIONS Data Protocol Modulation Tvpe Frequency band Identification Event Transmission Range in open space Battery Current Consumption Operating temperature Range Dimensions Weight inc battery This device complies with FreeWave FSK 868MHz 433MHz Option Unique ID serial number 24 bit Arm Disarm Stay Control Panic Low Bat up to 300 m Lithium 3 6V Type XL 050F Size 1 2AA Standby lt 1 uA Operator Mode 16 mA Transmission 30 mA 0 C to 50 C 133mm x 75mm x 30mm 225 gr European Council Directive EMC 89 336 EEC EN50130 4 EN301489 EN300220 EN50081 SAFETY 73 23 EEC EN60950 ITE CROW ELECTRONIC ENGINEERING LTD CROW WARRANTY POLICY CERTIFICATE This Warranty Certificate is given in favor of the purchaser hereunder the Purchaser purchasing th
5. e products directly from Crow or from its authorized distributor Crow warrants these products to be free from defects in materials and workmanship under normal use and service for a period of 24 months from the last day of the week and year whose numbers are printed on the printed circuit board inside these products hereunder the Warranty Period Subject to the provisions of this Warranty Certificate during the Warranty Period Crow undertakes at its sole discretion and subject to Crow s procedures as such procedures are form time to time to repair or replace free of charge for materials and or labor products proved to be defective in materials or workmanship under normal use and service Repaired products shall be warranted for the remainder of the original Warranty Period All transportation costs and in transit risk of loss or damage related directly or indirectly to products returned to Crow for repair or replacement shall be borne solely by the Purchaser Crow s warranty under this Warranty Certificate does not cover products that is defective or shall become defective due to a alteration of the products or any part thereof by anyone other than Crow b accident abuse negligence or improper maintenance c failure caused by a product which Crow did not provide d failure caused by software or hardware which Crow did not provide e use or storage other than in accordance with Crow s specified operating and storage instruc
6. e no personal injury or property loss or damage as a result Consequently Crow shall have no liability for any personal injury property damage or any other loss based on claim that these products failed to give any warning If Crow is held liable whether directly or indirectly for any loss or damage with regards to these products regardless of cause or origin Crow s maximum liability shall not in any case exceed the purchase price of these products which shall be the complete and exclusive remedy against Crow CROW ELECTRONIC ENGINEERING LTD ISRAEL Crow Electronic Engineering Ltd 12 Kineret St Airport Citv P O Box 293 Ben Gurion Airport 70100 Tel 972 3 9726000 Fax 972 3 9726001 E mail support crow co il USA 2160 North Central Road Fort Lee N J 07024 Tel 1 800 GET CROW or 201 944 0005 Fax 201 944 1199 E mail support crowelec com AUSTRALIA 429 Nepean HWY Brighton East Vic 3187 Tel 61 3 9596 7222 Fax 61 3 9596 0888 E mail crow crowaust com au POLAND VIDICON SP ZO O 15 Povazkowska St 01 797 Warsaw Poland Tel 48 22 562 3000 Fax 48 22 562 3030 E mail vidicon vidicon pl LATIN AMERICA CROW LATIN AMERICA 5753 NW 151 Street MIAMI LAKES FL 33014 USA Tel 1 305 823 8700 Fax 1 305 823 8711 E mail sales crowlatinamerica com ITALY DEATRONIC VIA Giulianello 4 14 00178 ROMA ITALY Tel 39 0676 12912 Fax 39 0676 12601 E mail info deatronic com These instructions
7. r channel 4 The keypad buzzer will beep once for a second to indicate learn mode has been initiated and the FW RCV board LED will flash The radio signal you wish to load must transmit a signal within 30 seconds from entering learn mode otherwise the panel will time out and no code will be loaded If a valid code is received within the 30 seconds the keypad will 2 give 3 short beeps and exit learn mode To remove a loaded radio channel enter in the code load address as above eg P614E then without operating the transmitter and before the 30 second timer expires press the Enter button This will remove the code loaded against this address in this case radio channel 4 HOW TO CHANGE OR ADD CODES Add Getting into installer mode LED indication New User User 1 oP oP PROG INSTALLER AN PROG C 4C ENTER c7 CODE CENTER CF ENTER User 2 G oP PROG INSTALLER PROG ERR PROG T 2 C77 ENTER C77 CIO DE C77 ENTER c Gn Dest PROG INSTALLER PROG ERR PROG 7 37 ENTER CP CjOID E C gt ENTER PED usera PROG INSTALLER PROG ERR PROG C 40 ENTER gt CjOIDE gt ENTER gt GER Remove user PROG 7 INSTALLER PROGIERR PROG X7 User Number 77 ENTER gt ENTER CF ENTER Installer PROG V7 INSTALLER PROG ERR PROG J o ENTER CF yew CIOD E ENTER c GER 22 HOW TO ENROLL COMMANDS TO THE WIRELESS CONTROL PANEL FIRST
8. tions There are no warranties expressed or implied of merchantability or fitness of the products for a particular purpose or otherwise which extend beyond the description on the face hereof This limited Warranty Certificate is the Purchaser s sole and exclusive remedy against Crow and Crow s sole and exclusive liability toward the Purchaser in connection with the products including without limitation for defects or malfunctions of the products This Warranty Certificate replaces all other warranties and liabilities whether oral written non mandatory statutory contractual in tort or otherwise In no case shall Crow be liable to anyone for any consequential or incidental damages inclusive of loss of profit and whether occasioned by negligence of the Crow or any third party on its behalf for breach of this or any other warranty expressed or implied or upon any other basis of liability whatsoever Crow does not represent that these products can not be compromised or circumvented that these products will prevent any person injury or property loss or damage by burglary robbery fire or otherwise or that these products will in all cases provide adequate warning or protection Purchaser understands that a properly installed and maintained product may in some cases reduce the risk of burglary fire robbery or other events occurring without providing an alarm but it is not insurance or a guarantee that such will not occur or that there will b