Home
MiiNePort E2 User`s Manual
Contents
1. amp Main Menu o S Accessible IP List LO Overview Basic Settings Enable the accessible IP list Disable will allow all IP s connection request EA Advanced Settings No Active IP Address Netmask Accessible IP List 1 E SNMP Agent 2 DIO Settings 3 Serial Command Mode 4 Miscellaneous 5 4 Maintenance a Save and Restart e 8 9 10 dl 12 13 14 15 16 Submit e To allow access to a specific I P address Enter the IP address in the corresponding field enter 255 255 255 255 for the netmask e To allow access to hosts on a specific subnet For both the IP address and netmask use 0 for the last digit e g 192 168 1 0 and 255 255 255 0 e To allow unrestricted access Deselect the Enable the accessible IP list option Refer to the following table for more configuration examples Allowed Hosts Entered IP address Netmask Any host Disable 192 168 1 120 192 168 1 120 255 255 255 255 192 168 1 1 to 192 168 1 254 192 168 1 0 255 255 255 0 192 168 0 1 to 192 168 255 254 192 168 0 0 255 255 0 0 192 168 1 1 to 192 168 1 126 192 168 1 0 255 255 255 128 192 168 1 129 to 192 168 1 254 192 168 1 128 255 255 255 128 SNMP Agent To enable the SNMP agent function select the Enable option for SNMP under Configuration amp Main Menu a SNMP Agent Settings A Overview EA Basic Settings Configuration EA Advanced Settings SNMP OEnable ODisable
2. A 47 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set TCP max connection Command code TM Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 RTM1 1 System requests maximum connection number for port 1 and channel 1 IRTMO4 MiiNePort reports maximum connection number as 4 TCP ignore jammed IP Command code TJ Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters 1 Enable or O Disable RTJ1 2 System requests jammed IP policy for port 1 s channel 2 IRTJO1 MiiNePort reports ignore jammed IP as Enable TCP inactivity time Command code TV Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters TCP inactivity time RTV1 0 System requests inactivity time for port 1 IRTVOO MiiNePort reports inactivity time as 0 UDP destination address Command code UD Command parameters Three numbers separated by a semicolon denote port index MCSC channel index and destination address index from 1 to 4 For an MCSC disabled port the channel index is 0 Reply parameters Begin addre
3. Index DIO port MiiNePort E2 PIN number 0 DIOO PIN15 1 DIO1 PIN16 2 DIO2 PIN16 3 DIO3 PIN18 Reply parameters 1 output or O input note that for the MiiNePort E2 this configuration is available if a specific PIN function is set to DIO GPM1 System requests DIO1 s initial mode for this MiiNePort IGPMO01 MiiNePort reports DIO1 s initial mode as output A 17 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set DI O initial state Command code PS Command parameters DIO port index For the MiiNePort E2 the index is as follows Index DIO port MiiNePort E2 PIN number 0 DIOO PIN15 1 DIO1 PIN16 2 DIO2 PIN17 3 DIO3 PIN18 Reply parameters 1 high or O low note that this function is configuration only if specific DIO port is set to initial output GPSOJ System requests DIO0 s initial state for this MiiNePort GPSOOJ MiiNePort reports DIOO s initial state is low Serial command mode trigger Command code CT Command parameters N A Reply parameters serial command mode trigger index as shown in the following table Disabe H W control pin DIO1 Activated by characters WIN R O Activated by break signal Note that this configuration is valid only if port 1 s operation mode is not set to MCSC GCT System requests serial command mode trigg
4. IGFP012344d MiiNePort reports RFC2217 local listen port is 1234 TCP Server Connection Control Command code TS Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters TCP server connection control as shown in the following table 0 Always accept Accept with DSR on GTS1 0 System requests TCP server connection control for port 1 IGTS00 MiiNePort reports incoming policy as Always accept TCP Alive Check Time Command code TA Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters TCP alive check time GTA1 0 System requests TCP alive check time for port 1 IGTA05 MiiNePort reports TCP alive check time as 5 minutes TCP Port Command code TP Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters TCP port GTP1 0 System requests TCP port for port 1 GTP04100 MiiNePort reports TCP port as 4100 A 13 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set TCP command port Command code TO Command parameters Two numbers separated by a semi
5. LED Color Meaning Left Amber 10BASE T Link Activity constant on when link existed blinks when data transmitting Right Green 100BASE TX Link Activity constant on when link existed blinks when data transmitting When using a private IP address for the module which is the factory default make sure that netmask and IP settings are configured appropriately in order to access the module from a host on the network 2 3 MiiNePort E2 Getting Started Connecting to a Serial Device To connect to a serial device for testing and development purposes the module should be installed onto the evaluation board Make sure the serial interface is correctly chosen before connecting the evaluation board to the serial device Refer to Selecting the Serial I nterface section above when you are using jumper blocks to select the serial interface on the evaluation board The module s serial signals are routed to and from the RS 232 or RS 485 COM port on the evaluation board Use a serial data cable to connect the serial device to the COM port on the evaluation board Digital 1 O Channel Settings Each module has 4 digital I O DIO channels Refer to the MiiNePort E2 Module Pin Assignment section in Chapter 1 for the module s configurable DIO pin descriptions Refer to the Evaluation Board Layout section in Chapter 1to select corresponding settings on the evaluation board All 4 DIO channels may be configured by software A DI
6. MiiNePort E2 Web Console Configuration S Registers No S Register Description default value Remarks 1 so Ring to auto answer default 0 2 s1 Ring counter always 0 no action applied 3 S2 Escape code character default 43 ASCII 4 s3 Return character default 13 ASCII 5 S4 Line feed character default 10 ASCII 6 S5 Backspace character default 8 ASCII 7 S6 Wait time for dial tone always 2 unit sec no action applied 8 S7 Wait time for carrier default 3 unit sec 9 s8 Pause time for dial delay always 2 unit sec no action applied 10 s9 Carrier detect response time always 6 unit 1 10 sec no action applied 11 S10 Delay for hang up after carrier always 14 unit 1 10 sec no action applied 12 S11 DTMF duration and spacing always 100 ms no action applied 13 S12 Escape code guard time default 50 unit 1 50 sec to control the idle time for TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Required O min TCP connection is not closed due to an idle TCP connection 1 to 99 min The MiiNePort E2 closes the TCP connection automatically if there is no TCP activity for the given time Local TCP port Setting Factory Default Necessity 1 to 65535 4001 Required The TCP port that other devices must use to contact this device To avoid conflicts with standard TCP ports the default is set
7. RSD1 System requests port 1 s Data bits for this MiiNePort IRSDO8 MiiNePort reports Data bits as 8 Stop bits Command code SS Command parameters Port index Reply parameters MiiNePort s stop bits index Stop Bits Index Table 0 Stop bits is 1 Stop bits is 1 5 2 Stop bits is 2 RSS1 System requests port 1 s Stop bits for this MiiNePort IRSSOO MiiNePort reports Stop bits as 1 Parity Command code SP Command parameters Port index Reply parameters MiiNePort s Parity index as follows None Odd Even Mark Space B W N R O RSP1 System requests port 1 s Parity for this MiiNePort IRSPOO MiiNePort reports Parity as None A 41 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Flow control Command code SL Command parameters Port index Reply parameters MiiNePort s Flow control index as follows 0 None 1 RTS CTS 2 XON XOFF 3 DTR DSR 2RSL1 System requests port 1 s Flow control for this MiiNePort IRSLO1 MiiNePort reports Flow control as RTS CTS FIFO Command code SF Command parameters Port index Reply parameters 1 Enable or 0 Disable MiiNePort s FIFO RSF1 System requests port 1 s FIFO for this MiiNePort IRSFO1 MiiNePort reports FIFO as Enable Interface Command code
8. Steady On Power is on and the MiiNePort is functioning normally Blinking every 1 second 1 The device server has been located by NPort search utility s location function 2 Auto config complete Blinking every 0 5 second Indicates a LAN IP conflict or DHCP or BOOTP server did not respond properly Serial Signal LED LED D3 shows the TxD status LED D4 shows the RxD status LED D5 shows the DTR status LED D6 shows the CTS status LED D7 shows the DSR status LED D8 shows the DCD status LED D9 to show the RTS status Digital Output LED LED D10 shows the DOO status LED D11 shows the DO1 status LED D12 shows the DO2 status LED D13 shows the DO3 status 1 9 2 Getting Started This chapter includes information about how to install MiiNePort E2 Series modules for development and testing The following topics are covered in this chapter o o o o o o o o Wiring Precautions Installing the MiiNePort E2 onto the MiiNePort E2 ST Selecting the Serial I nterface Connecting the Power Connecting to the Network Connecting to a Serial Device Digital I O Channel Settings Schematic Design Guide MiiNePort E2 Getting Started Wiring Precautions This section describes some important safety precautions that you should pay attention to before proceeding with any installation ATTENTION Be sure to disconnect the power cord before installing or wiring the evaluation board ATTENTION D
9. 0 Start up None 1 Any character None 2 Any character Inactivity time 3 DSR On DSR OFF 4 DSR On None 5 DCD On DCF OFF 6 DCD On None STC1 0 1J System sets TCP client connection control as Any character None for port 1 ISTCOJ MiiNePort reports command executed successfully TCP destination address Command code TI Command parameters Port index MCSC channel index destination address index 0 for destination address and 1 to 3 for alternated addresses Parameters are separated by a semicolon For an MCSC disabled port the channel index is 0 Reply parameters N A ST11 0 0 192 168 1 2 4001 System sets destination address as 192 168 1 2 and port as 4001 for port 1 ISTTO MiiNePort reports command executed successfully TCP Client local port Command code TL Command parameters Port index MCSC channel index and TCP local port Every parameter is separated by semicolon For MCSC disabled port channel index shall be 0 Reply parameters N A STL1 2 5002J System sets TCP client local port as 5002 for port 1 s channel 2 ISTLOJ MiiNePort reports command executed successfully A 31 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set TCP max connection Command code TM Command parameters Port index MCSC channel index and maximum connection number Parameters are separated by a semicolon Fo
10. ISCTO MiiNePort reports command executed successfully Serial command mode trigger characters Command code CC Command parameters serial command mode trigger characters in hex separated by a semicolon Note that this configuration is valid only if serial command mode trigger method is set to Activated by characters Reply parameters N A SCC45 66 67 System sets serial command mode trigger characters as ABC 0x656667 ISCCOd MiiNePort reports command executed successfully A 34 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Serial command mode trigger only at boot up Command code CB Command parameters 0 if serial command mode can be triggered at any time or 1 if it can only be triggered at boot up Note that this configuration is valid only if serial command mode trigger method is set to Activated by characters Reply parameters N A SCB1 System sets serial command mode can only be triggered by characters at boot up ISCBO MiiNePort reports command executed successfully Gratuitous ARP Command code VA Command parameters 1 and send period if gratuitous ARP is enable otherwise 0 Reply parameters N A SVA1 300 System sets gratuitous ARP as Enable and send period as 300 sec for this MiiNePort ISVAO MiiNePort reports command executed successfully Command Code for Re
11. 3 gt Accessible IP list 4 gt SNMP agent lt 5 gt DIO settings lt 6 gt Serial command mode settings lt gt Miscellaneous lt 8 gt Console settings lt a gt Configuration to lt c Change password 1 gt Load factory def lt m gt Monitor Cp Ping Cu View settings lt s Save and restart lt q Quit Key in your selection SCM Serial Command Mode ols ault The MiiNePort E2 s SCM Serial Command Mode allows the module s parameters to be retrieved and configured through the serial port This is accomplished using specially parsed commands sent to the module through the serial port SCM is often used when your device has already been used in a real application and a configuration change such as changing the device s IP address with the device s key pad is required Refer to Chapter 7 Web Console Configuration for details on how to access and use the MiiNePort E2 s SCM Refer to Appendix A Introduction to SCM Serial Command Mode for the SCM command set instructions 5 Initial IP Address Configuration When setting up your MiiNePort E2 module for the first time the first thing you should do is configure the IP address This chapter introduces the methods that can be used to configure the module s IP address For more details about network settings refer to the Network Settings section in Chapter 7 Web Console Configuration The following topics are covered in this chapter
12. EZPage utilizes Moxa s proprietary NECI protocol to control and modify the configurations e To browse customized web console you need to upload your own EZPage to MiiNePort We will show the detailed steps in the following section e The hyper link http Device s IP index htm specifies the location of EZPage content and is the first entry point for users to access the MiiNePort s web console Then MiiNePort will redirect the Moxa default web consoles to http Device s i p moxa home htm If customized web page does not exist in MiiNePort it will show Moxa default web console of MiiNePort ATTENTION 1 EZPage provides a maximum size of packed file is 512K Bytes 2 EZPage example is compiled with JDK V1 6 We strongly recommend that you could re compile this example with another version of J DK if needed Step 1 Compile EZPage You can compile all java files in the src jar directory by themselves or use src jar compile bat to complete this task clean bat 1KB pejcompile bat 1 KB COPYING MOXA TXT 2KB E EZPage java 69 KB foldercl gif 1 KB folderop gif 1KB ta messages properties 1KB al neci jar 85 KB pack bat 1KB E ps JPG 6KB VERSION TXT 1KB Execute compile bat and make sure the compiler version is correct if you have any problems compiling this example set conet rer verfi javac target C0 ER_VER com moxa library mxci java javac target COMPLIER_UER com moxa
13. GNI System requests IP address for this MiiNePort IGNI0192 168 127 254 MiiNePort reports IP address as 192 168 127 254 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Netmask Command code NM Command parameters N A Reply parameters MiiNePort s Netmask address 2GNM System requests Netmask address for this MiiNePort GNM0255 255 255 0 MiiNePort reports netmask as 255 255 255 0 Gateway Command code NG Command parameters N A Reply parameters MiiNePort s Gateway address GNGe System requests Gateway address for this MiiNePort GNGO255 255 255 255 MiiNePort reports Gateway address as 255 255 255 255 DNS Command code ND Command parameters The index 1 or 2 of DNS server Reply parameters MiiNePort s DNS address GND1 System requests DNS server 1 address for this MiiNePort GND0192 168 1 2 MiiNePort reports DNS server 1 address as 192 168 1 2 PHY Speed Command code NS Command parameters N A Reply parameters MiiNePort s PHY speed as follows 0 PHY auto negotiation is enabled 10 PHY speed is forced to 10Mbps with half duplex 11 PHY speed is forced to 10Mbps with full duplex 100 PHY speed is forced to 100Mbps with half duplex 101 PHY speed is forced to 100Mbps with full duplex GNS System requests PHY speed setting for this MiiNePort IG
14. 70 Gopler Protocol 79 Finger Protocol 80 World Wide Web HTTP 107 Remote Telnet Service 111 Sun Remote Procedure Call Sunrpc 119 Network news Tcanster Protocol NNTP 123 Network Time protocol nnp 161 SNMP Simple Network Mail Protocol 162 SNMP Traps 213 IPX Used for IP Tunneling B 2 C Auto IP Report Protocol There are several ways to configure the IP address of an MiiNePort E2 Series module One way is with DHCP Client When you set up the module to use DHCP Client for IP address configuration it will automatically send a DHCP request over the network to find the DHCP server The DHCP server will then send an available IP address to the module with an expiration time The module will use this IP address until the expiration time has been reached When the expiration time has been reached the process will repeat and module will send another DHCP request to the DHCP server Therefore a module may end up using more than one IP address while it is connected to the network The module has a built in IP address report function that will send its IP data to a specific IP address and port number when it is not using a Static or fixed IP address The IP address report parameters may be configured in the Network Settings in the web console Enter the IP address and the port number of the PC that is to receive this information as shown below A Main Menu Miscellaneous overview EA Basic Settings PHY Speed EA Advance
15. MiiNePort E2 Introduction MitNePort E2 Module Dimensions units mm in g a e a S 3 e g o a g 1 wo I Ot g e 2 R 29 1 14 o 27 17 1 07 w g 11 43 0 45 g2 1 64 0 06 EOS 1 27 0 05 8 23 0 32 17 0 67 a DUI Panel Layout and Pin Assignments Evaluation Board Layout 1 2 1 MiiNePort E2 Module Location O ta b dl d B III 2 Ethernet RJ 45 Connector lea gal 3 Serial Interface Jumper ps ar ay AA z a 8 AQOVOVOVODO 4 Power Switch Ea dl i 1OOOOOOOOOO El ar El ppp n 13 5 Power Jack lq jH eb 6 Power amp Ready LED 7 DB9 Male Connector 8 Serial Port Status LED 9 Digital IO Terminal Block 3 10 Digital Output LED 11 Digital Input Output Mode a 12 Digital Input Switch Se g o 9 abl le 13 11 E O 55585888 n Circuit Pad n ELL I TIT EL MiiNePort E2 Introduction Pin Assignments MiiNePort E2 Module Pin Assignment Bottom Panel of the MiiNePort E2 Module 10 pr MOXA MiiNe MPA702 I VOB D6A328 008 1 0936 JP1 Pin Signal Name Function 1 Ethernet Tx Ethernet Transmit Data 2 Ethernet Tx Ethernet Transmit Data 3 Ethernet Rx Ethernet Receive Data 4 Ethernet Rx Ethernet Receive Data JP2 Pin Signal Name Function 1 100M LED Ethernet 100M LED 2 10M LED
16. O Static vs Dynamic I P Address O Factory Default I P Address O ARP o Telnet Console MiiNePort E2 Initial I P Address Configuration Static vs Dynamic IP Address You should first determine whether the module will be assigned a Static IP or Dynamic IP either DHCP or BOOTP application e Ifthe module is used in a Static IP environment you need to configure the IP address directly e If the module is used in a Dynamic IP environment you need to configure the module to obtain an IP address dynamically with DHCP DHCP BOOTP BOOTP or AUTOIP ATTENTION Consult your network administrator on how to reserve a fixed IP address for the module in the MAC IP mapping table when using a DHCP Server or BOOTP Server For most applications you should assign a fixed IP address to the module Factory Default I P Address The MiiNePort E2 module is configured with the following default private IP address 192 168 127 254 IP addresses of the form 192 168 xxx xxx are referred to as private IP addresses since it is not possible to directly access a device configured with a private IP address from a public network For example you would not be able to ping such a device from an outside Internet connection Applications that require sending data over a public network such as the Internet require setting up the server with a valid public IP address which can be leased from a local ISP ARP You can use the ARP Address Resolution P
17. Reply parameters TCP port GTL1 0J System requests for TCP client local port setting for port 1 1GTLO5002 MiiNePort reports TCP client local port is 4001 A 15 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set TCP inactivity time Command code TV Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters TCP inactivity time 2GTV1 0 System requests inactivity time for port 1 IGTVO00 MiiNePort reports inactivity time as 0 UDP serial format Command code UT Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters Serial format as follows 0 Raw data Packet command GUT1 0 System requests UDP serial format for port 1 IGUTO0 MiiNePort reports UDP serial format as Raw data UDP destination address Command code UD Command parameters Three numbers separated by a semicolon denote port index MCSC channel index and destination address index from 1 to 4 For an MCSC disabled port the channel index is 0 Reply parameters Begin address End address port GUD1 0 3 System requests UDP destination address 3 for port 1 GUD0192 168 1 3 192 168 1 8 4001 MiiNePort reports
18. Command code NM Command parameters MiiNePort s Netmask address Reply parameters N A SNM255 255 255 0 System sets Netmask as 255 255 255 0 ISNMO MiiNePort reports command executed successfully A 21 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Gateway Command code NG Command parameters MiiNePort s Gateway address Reply parameters N A SNG192 168 1 254 System sets Gateway as 192 168 1 254 ISNGO MiiNePort reports command executed successfully DNS Command code ND Command parameters The index 1 2 and DNS server address separated by a semicolon Reply parameters N A SND1 192 168 1 123 System sets DNS1 as 192 168 1 123 ISNDO MiiNePort reports command executed successfully PHY Speed Command code NS Command parameters N A Reply parameters MiiNePort s PHY speed as follows 0 PHY auto negotiation is enabled 10 PHY speed is forced to 10Mbps with half duplex 11 PHY speed is forced to 10Mbps with full duplex 100 PHY speed is forced to 100Mbps with half duplex 101 PHY speed is forced to 100Mbps with full duplex SNS10 System forces PHY speed to 10Mbps with half duplex ISNSO MiiNePort reports command executed successfully Enable Disable SNMP Command code MS Command parameters 1 Enable or 0 Disable MiiNePort s SNMP agent Reply p
19. File COM Mapping Configuration View Help E Exit Add No COM Port Address 1 Address 2 1 COM1 192 168 127 254 950 966 Portl Information Ports that have been activated will appear in black NPort Windows Driver Manager DER File COM Mapping Configuration View Help n Exit Add No COM Port Address 1 Address 2 1 COM1 192 168 127 254 950 966 Port The Linux Real TTY Driver OF Mo INES Obtain the driver file from the included CD ROM or the Moxa website at http www moxa com Log in to the console as a super user root Execute cd to go to the root directory Copy the driver file npreal2xx tgz to the directory Execute tar xvfz npreal2xx tgz to extract all files into the system Execute tmp moxa mxinst For RedHat AS ES WS and Fedora Corel append an extra argument as follows tmp moxa mxinst SP1 The shell script will install the driver files automatically After installing the driver you will be able to see several files in the usr lib npreal2 driver folder gt mxaddsvr Add Server mapping tty port gt mxdelsvr Delete Server un mapping tty port gt mxloadsvr Reload Server gt mxmknod Create device node tty port gt mxrmnod Remove device node tty port gt mxuninst Remove tty port and driver files At this point you will be ready to map the MiiNePort E2 serial port to the system tty port Mapping TTY Ports Make sure that you set the operation mode
20. Note that this configuration is valid only if port 1 s operation mode is not set to MCSC RCT System requests serial command mode trigger method for this MiiNePort IRCTO1 MiiNePort reports serial command mode is triggered by DIO1 Serial command mode trigger characters Command code CC Command parameters N A Reply parameters serial command mode trigger characters in hex separated by a semicolon Note that this configuration is valid only if serial command mode trigger method is set to Activated by characters RCCeH System requests serial command mode trigger characters for this MiiNePort IRCCO58 58 58 MiiNePort reports serial command mode triggered by XXX 0x585858 A 50 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Serial command mode trigger only at boot up Command code CB Command parameters N A Reply parameters 0 if serial command mode can be triggered at any time or 1 if it can only be triggered at boot up Note that this configuration is valid only if serial command mode trigger method is set to Activated by characters RCB System requests serial command mode for this MiiNePort IRCBO1 MiiNePort reports serial command mode can only be triggered by characters at boot up Gratuitous ARP Command code VA Command parameters N A Reply parameters 1 and send period if gratuitous
21. Reply parameters MiiNePort s data packing length as follows GOL1 0 System requests port 1 s data packing length for this MiiNePort GOLO256 MiiNePort reports data packing length as 256 GOL1 2 When port 1 is set to MCSC system requests the data packing length for channel 2 of port 1 GOLO128 MiiNePort reports data packing length as 128 A 10 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Delimiter Command code OD Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters MiiNePort s delimiter setting delimiter1 enable disable hex1 delimiter2 enable disable hex2 GOD1 0 System requests port 1 s delimiter setting for this MiiNePort 1GOD1 10 1 13 MiiNePort reports delimiter 1 as Enable and hex code as 10 delimiter 2 as Enable and hex code as 13 Delimiter Process Command code OT Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters MiiNePort s delimiter process 0 Do nothing 1 Delimiter 1 2 Delimiter 2 3 Strip Delimiter GOT1 0 System requests port 1 s delimiter process for this MiiNePort IGOT02 MiiNePort reports delimiter pr
22. netmask and gateway settings IP Address Setting Description Factory Default E g 192 168 1 1 192 168 127 254 Required IP addresses of the form x x x 0 and X X X 255 are invalid An IP address is a number assigned to a network device such as a computer as a permanent address on the network Computers use the IP address to identify and talk to each other over the network Choose a proper IP address that is unique and valid in your network environment Netmask Setting Factory Default Necessity E g 255 255 255 0 255 255 255 0 Required A subnet mask represents all the network hosts at one geographic location in one building or on the same local area network When a packet is sent out over the network the module will use the subnet mask to check whether the host specified in the packet is on a local network segment If the address is on the same network segment as the module a connection is established directly from the module Otherwise the connection is established through the default gateway Gateway Setting Factory Default Necessity E g 192 168 1 1 None Optional A gateway acts as an entrance to another network Usually the computers that control traffic within the network or at the local Internet service provider are gateway nodes The module needs to know the IP address of the default gateway computer in order to communicate with the hosts outside the loca
23. Delimiter Command code OD Command parameters Port index MCSC channel index delimiter1l enable disable delimiter character 1 by hex delimiter 2 enable disable and delimiter character 2 by hex Parameters are separated by a semicolon For an MCSC disabled port the channel index is 0 Reply parameters N A SOD1 2 1 10 1 13 System sets channel 2 of port 1 s delimiter 1 as Enable and hex code as 10 Delimiter 2 as Enable and hex code as 13 ISOD0 MiiNePort reports command executed successfully A 27 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Delimiter Process Command code OT Command parameters N A Reply parameters Port index MCSC channel index and delimiter process Parameters are separated by a semicolon For an MCSC disabled port the channel index is 0 SOT1 0 2 System sets port 1 s delimiter process as Delimiter 2 ISOTO MiiNePort reports command executed successfully Force Transmit Command code OF Command parameters Port index MCSC channel index and force transmit timeout Parameters are separated by a semicolon For an MCSC disabled port the channel index is 0 Reply parameters N A SOF1 0 5 System sets port 1 s force transmit timeout as 5 ISOFO MiiNePort reports command executed successfully Real COM TCP alive check time Command code RA Co
24. E2 is the smallest footprint in the world making it easy to fit into virtually any existing serial device Package Checklist Module Package one of the following e MiiNePort E2 0 to 55 C operating temp 50 bps to 230 4 Kbps baudrate e MiiNePort E2 H 0 to 55 C operating temp 50 bps to 921 6 Kbps baudrate e MiiNePort E2 T 40 to 85 C operating temp 50 bps to 230 4 Kbps baudrate e MiiNePort E2 H T 40 to 85 C operating temp 50 bps to 921 6 Kbps baudrate Starter Kit Package e MiiNePort E2 module MiiNePort E2 or MiiNePort E2 H only e MiiNePort E2 evaluation board e Universal power adaptor e 2 power cords e Null modem serial cable e Cross over Ethernet cable e Document and Software CD e Quick Installation Guide e Warranty Card NOTE Please notify your sales representative if any of the above items is missing or damaged Product Features All MiiNePort E2 Series modules have the following general features e Smallest embedded device server on the market only 29 x 17 x 12 6 mm e Extremely low power consumption only 140 mA 3 3 VDC or 92 mA input 5 VDC input e Uses the MiiNe Moxa s second generation SoC e NetEZ technology makes integration incredibly easy e Versatile choice of operation modes Real COM TCP Server TCP Client RFC2217 UDP Ethernet Modem and MCSC Moxa s NetEZ technology is designed to give serial device manufacturers a range of powerful tools for integrating Ethernet ca
25. If you use other web browsers remember to enable the functions to allow cookies that are stored on your computer or allow per session cookies MiiNePort E2 modules only use cookies for password transmission ATTENTI ON Refer to Chapter 5 I nitial I P Address Configuration for instructions on IP configuration The examples in this chapter use the factory default IP address 192 168 127 254 3 The web console will open On this page you can see a brief description of the web console s function groups in the left part of the page You can also see a configuration overview of your MiiNePort E2 module amp Main Menu 7 Welcome to MiiNePort web console 1 Overview HA Basic Settings Model name MiiNePort E2 9 Advanced Settings Serial No TA E z Device name MiiNePort Maintenance Firmware version 1 0 Build 10060317 Save and Restart Ethernet IP address 192 168 127 254 Ethernet MAC address 00 90 E8 00 07 79 Up time 0 days 00h 02m 49s Serial communication E Data Mode 7 2 MiiNePort E2 Web Console Configuration Web Console Fundamentals On the web console the left panel is the navigation panel and contains an expandable menu tree for navigating among the various settings and categories When you click on a menu item in the navigation panel the main window will display the corresponding options for that item Configuration changes can then be made in the main window For example if you click on Basic Settings gt
26. choosing the proper operating mode in this chapter refer to subsequent chapters for details on configuration parameters The following topics are covered in this chapter Overview Real COM Mode TCP Server Mode TCP Client Mode RFC2217 Mode UDP Mode Ethernet Modem Mode MCSC Mode gQOaaaaada MiiNePort E2 Choosing the Proper Operation Mode Overview MiiNePort E2 modules act as a bridge to connect your serial devices to the Ethernet The built in TCP IP stack means less time spent on programming networking protocols With one step you can choose the proper operation mode then use your computer to access manage and configure your serial devices from anywhere in the world over the Internet Traditional SCADA and data collection systems rely on serial ports RS 232 422 485 to collect data from various kinds of instruments Since MiiNePort E2 modules convert between serial and Ethernet signals your SCADA and data collection system can be made accessible from every device connected to a standard TCP IP network regardless of whether the devices are used locally or at a remote site Real COM mode and six different socket modes TCP Server TCP Client Ethernet Modem RFC2217 UDP and MCSC are available on MiiNePort E2 modules The main difference between the TCP and UDP protocol is that TCP guarantees delivery of data by requiring the recipient to send an acknowledgement to the sender UDP does not require this type of verifica
27. connection requested from Host B then proceed with data transmission channels Serial Device with MiiNePort E2 For details on MCSC s functionality and configuration refer to Chapter 8 NetEZ Technologies MCSC 3 5 4 Choosing the Configuration Tool The MiiNePort E2 supports several tools for configuring the module In this chapter we briefly describe the options available and appropriate situations for using those options The following topics are covered in this chapter o o o o Utility Console Web Console Telnet Console SCM Serial Command Mode MiiNePort E2 Choosing the Configuration Tool Utility Console NPort Search Utility You can find NPort Search Utility on the CD ROM NPort Search Utility is designed for Windows and is mainly used to search for the MiiNePort E2 modules and for assigning IP addresses Refer to the Web Console for additional configuration information 19 NPort Search Utility File Function View Help F 2 a x 8 E Exit Search Search P Locate Console LAN1 MAC Address LANT IP Address LAN2 MAC Address LAN2 IP Address Status NPort Windows Driver Manager NPort Windows Driver Manager is intended for use with Real COM mode The software manages the installation of drivers that allow you to map unused COM ports on your PC to serial ports on the MiiNePort E2 NPort Windows Driver Manager File COM Mapping Configuration View Help nh Gh Exit Add No
28. t i D MiiNePort E2 Client Serial Device with MiiNePort E2 3 3 MiiNePort E2 Choosing the Proper Operation Mode RFC2217 Mode RFC2217 is an industrial public protocol for sharing serial devices over TCP IP Ethernet networks RFC2217 is similar to Moxa s proprietary Real COM mode in that it allows users to continue using software that was written for pure serial communications applications Each module comes equipped with COM drivers for Windows systems 95 and above The module s serial port is mapped by the driver to an IP address and port number The driver intercepts data sent to the host s COM port packs it into a TCP IP packet and then redirects it through the host s Ethernet card Data Transmission Host COM 3 IP Port TCP IP Ethernet i Pinner E2 H RFC2217 Mode Serial Device with MiiNePort E2 UDP Mode UDP is similar to TCP but is faster and more efficient Although data can be broadcast to or received from multiple network hosts UDP does not support verification of data and consequently would not be suitable for applications where data integrity is critical However UDP would be suitable for message display applications Data Transmission TCP IP Ethernet Directly proceed data transmission no connection required PA TA gt MiiNePort E2 UDP Mode Serial Device with MiiNePort E2 3 4 MiiNePort E2 Choosing the Proper Operation Mode ATTENTION Th
29. 256 Delimiter Command code OD Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters MiiNePort s delimiter setting delimiter1 enable disable hex1 delimiter2 enable disable hex2 ROD1 0 System requests port 1 s delimiter setting for this MiiNePort ROD1 10 1 13 MiiNePort reports delimiter 1 as Enable and hex code as 10 delimiter 2 as Enable and hex code as 13 A 43 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Delimiter Process Command code OT Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters MiiNePort s delimiter process 0 Do nothing 1 Delimiter 1 2 Delimiter 2 3 Strip Delimiter ROT1 0 System requests port 1 s delimiter process for this MiiNePort IROTO2 MiiNePort reports delimiter process as Delimiter 2 Force Transmit Command code OF Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters MiiNePort s force transmit timeout ROF1 0 System requests port 1 s force transmit timeout for this MiiNePort ROFO0O MiiNePort re
30. 5 1 Static vs Dynamic IP Address 0 cnn rra nera n rra 5 2 Factory Defa Ult LP ACLS iiss eStart nthe teat are 5 2 AR tii 5 2 TElNeL COMSOlEanchatiettateataiadiieieiatelalnandarndanduciducaduradacaturnlacadurdasaianahanahenctanakenetanctantlnatenctnebaateaatadals 5 3 6 Utility Console and Driver Installation oomocncncncncncacacacacananannnnnnonnnnnnananancncnrararararanananananananananananananes 6 1 NPort Search Utility 2 Een e AAA KEANE tne ated 6 2 Installing NPort Search Utility 20 tenet tenet ene eae 6 2 NPort Search Utility Configuration 2 0 0 0 nn rn nn nn nr rr nr rn nn rr nn nena EEEE SEEE ESEE EEE 6 3 NPort Windows Driver Manager iia O neg O AS s da 6 4 Installing NPort Windows Driver Manager oooocccccccccoconcnnoncnnnncnnnnnnnnnnnnnn nn nn rn nn rra EEES PEERS EEE ESEE EESE E EEEE 6 4 Using NPort Windows Driver Manager occccccoccccccnccncnnoncnnnnnnnnnnnnn nn nn nn rn nn nr rr rr rn nr nn rn nn rn nnnnnnnnrnranannanss 6 6 THE EMNUX Real TTY DIV Oltra adel eae lalla alae alata af eeu dare tete tee tdt tati 6 8 Mapping POPES naa dado dro ooo 6 8 Removing Mapped TTY PortS ooooocccccnccccncnncncnnnncnnnnnnn nn nn rra nera rrn arrancar 6 9 Removing Linux Driver Fil S lt lt lt 00 6 00 0 000 00 000 0 0000 00 0005000 080 00 CG aa 6 9 The UNIX Fixed TTY DEV Se cota cite ci a a a ata ata 6 10 installing the UNIX Driver sinnene aaan aaa AAE A aA EnA a aida ada 6 10 Config ring the UNIX DAVE AA AA
31. 6 0 0 1 1 0 1 indicates that DIO 0 is in input mode and low status DIO 1 is in output mode and high status and DIO 2 is in input mode and high status C Code Example BOOL ReadMultipleDIO int start int end int mode int status packet packet DIOPacketStruct packet header command 5 Read Multiple DIO Commands header version 2 DIO protocol command version packet packet packet header length 2 data length data 0 start start of the DIO number data 1 end end of the DIO number send SocketFd char amp packet sizeof DIOHeaderStruct 2 0 Send Proc TCP packet ss the returned data here return RUE MiiNePort E2 DIO Commands Write Multiple DI Os Command Byte Descriptor Value Description 1 Header 6 command number fixed 2 Header 2 version fixed 3 Header any this byte is only used in the module s response 4 Header 6 8 10 data length depends on the number of channels being written 6 bytes for 2 channels 8 bytes for 3 channels 10 bytes for 4 channels 5 Data 0 1 2 starting DIO channel number Data 1 2 3 ending DIO channel number Data 0 1 1st DIO channel to be written 0 set to input mode 1 set to output mode 8 Data 0 1 1st DIO channel to be written 0 set to low 1 set to high 9 Data 0 1 2nd DIO channel to be written 0 set to input mode 1
32. 6 10 7 Web Console Configuration ocmonccnonncnnnncnnnncananennnnennnncnnnn cnn cnn enana rnnnnennnnrnnnnrnnnnrannnrnnnnrnnanrnnaneananennas 7 1 OPening YU BAM o e aa 7 2 Web Console RundamentalS aii yita eet AA daba AD ADA ADA eRe Ree RRC AREA RRA Al 7 3 Basi Settings it sects aac dar dela delve Sass A See a a Ud iets Sed asia Ui A Sed dha ade Gate eae Si alan se a 7 3 WN Teo al ae 8 0 0 iia 7 3 Serial Port Setlingsic astute iedededadobdedudy buted did ea 7 5 Operation MOdES ma A Ar 7 7 Advanced Settings aeriana aat ahaa EEA ai E EEA EE a i E EEEE AE E EEE AAE AE EE EAEE AAR 7 24 AGCOSSID G PANICLE soy tose Siva a a thea tang ang ag Jang a E A tana sana E E A E a 7 24 SNMP Agent sinoni A ce ish shat aA aAa aa a SAGA A aA aba Laas AGaGh Aba a aA aaa Lendl aAA KAA AA aa aA aAa AAAA CAAA 7 24 BONS lad ale eee ener bed 7 25 Serial Command Mode SCM cece cece rr rra rre rra 7 26 Miscellanous z eet aaa Aca rae a aa eae eile a Bia i 7 27 8 E F Maintenance a at A ected eet 7 28 Console Setting Saa Aaina rd a a a cc SAG 7 28 FirmWware Upgrade ro oO arti 7 28 Configuration TOD Si dit a dd ttt tect e ade tee ead oe decades 7 29 Change PASS WO A ao 7 30 NetEZ Technologies cccccecccececececeeeeceueueueueueuauauauauauauauauaueeeeaeeeeeeeueueueueueueuauauauauauauauauauauavareeecesueuguenens 8 1 EXPO Werder tak nth ian an ananenaaenadinnaaaadacaaadadannausitanadtetaagenantnaaaaaananananenananandadan dnt oa tat 8
33. 7 Web Console Configuration for additional settings NPort Windows Driver Manager Installing NPort Windows Driver Manager NPort Windows Driver Manager is intended for use with serial ports that are set to Real COM mode The software manages the installation of drivers that allow you to map unused COM ports on your PC to your device presented by MiiNePort E2 s serial port These drivers are designed for use with Windows XP 2003 Vista 2008 7 x86 x64 When the drivers are installed and configured devices that are embedded with the MiiNePort E2 will be treated as if they are attached to your PC s own COM ports 1 Click the INSTALL COM Driver button in the MiiNePort E2 Installation CD to install the NPort Windows Driver Once the installation program starts running click Yes to proceed 6 4 MiiNePort E2 Utility Console and Driver I nstallation 2 Click Next when the Welcome screen opens to proceed with the installation iG Setup NPort Windows Driver Manager Welcome to the NPort Windows Driver Manager Setup Wizard This will install NPort Windows Driver Manager Verl 13 on your computer It is recommended that you close all other applications before continuing Click Next to continue or Cancel to exit Setup 3 Click Browse to select the destination directory and then click Next to install program files to the directory displayed in the input box iG Setup NPort Windows Driver Manager Select Destination Locat
34. Command port Setting Factory Default Necessity 1 to 65535 966 Optional The Command port is a listen TCP port for P Serial Lib commands from the host In order to prevent a TCP port conflict with other applications the user can set the Command port to another port if needed P Serial Lib will automatically check the Command Port on the MiiNePort E2 so that the user does not need to configure the program Packing length Setting Factory Default Necessity 0 to 1024 0 Optional Default 0 The Delimiter Process will be followed regardless of the length of the data packet If the data length in bytes matches the configured value the data will be forced out The data length can be configured for 0 to 1024 bytes Set to 0 if you do not need to limit the length Delimiter 1 Setting Factory Default Necessity 00 to FF None Optional Delimiter 2 Setting Factory Default Necessity 00 to FF None Optional MiiNePort E2 Web Console Configuration Once the MiiNePort E2 receives both delimiters through its serial port it immediately packs all data currently in its buffer and sends it out the MiiNePort E2 s Ethernet port ATTENTION Delimiter 2 is optional If left blank then Delimiter 1 alone trips clearing of the buffer If the size of the serial data received is greater than 1 KB the MiiNePort E2 will automatically pack the data and send it to the Eth
35. Description 1 Header 1 command fixed 2 Header 2 version fixed 3 Header 0 1 2 3 command status error code 0 okay 4 5 6 OxFF 4 Header 3 data length fixed Data 0 1 2 3 desired DIO channel 6 Data 0 1 0 channel is in input mode 1 channel is in output mode 7 Data 0 1 0 channel status is low 1 channel status is high For example the 7 byte response sequence 1 2 0 3 0 0 0 indicates that DIO 0 is in input mode C Code Example BOOL ReadSingleDIO int port DIOPacketStruct packet packet header command 1 packet header version 2 packet header length 1 packet data 0 send SocketFd char port char amp packet Send TCP Packet Process th return TRUE returned data here Write Single DIO int mode int status read single DIO command DIO protocol version data length Number of the DIO sizeof DIOHeaderStruct 1 0 Command Byte Descriptor Value Description 1 Header 2 command number fixed 2 Header 2 version fixed 3 Header any this byte is only used in the module s response 4 Header 3 data length fixed 5 Data 0 1 2 3 desired DIO channel number 6 Data 0 1 0 set to input mode 1 set to output mode 7 Data 0 1 this byte is ignored for input mode 0 set to low 1 set to high For example the 7 byte command sequence 2 2 0 3 0 0 0 requests that DIO O be set t
36. Ethernet 10M LED 3 LRXD Receive Serial Data 4 LTXD Transmit Serial Data 5 LDCD Data Carrier Detect 6 RS485_EN RS 485 Enable 7 LRTS Request To Send 8 LDTR Data Terminal Ready 9 LDSR Data Set Ready 10 LCTS Clear To Send JP3 Pin Signal Name Function 1 DIOO Programmable Input Output 2 DIO1 Programmable Input Output 3 DIO2 Programmable Input Output 4 DIO3 Programmable Input Output 5 Reserved N A 6 Reserved N A 7 SW Reset Reset To Factory Default 8 GND Circuit Ground 9 Ready LED System is Ready LED 10 VCC Power Supply Evaluation Board Ethernet Port Pin Assignment RJ 45 Pin Signal 1 Tx 2 Tx 3 Rx 6 Rx 1 7 MiiNePort E2 Introduction Evaluation Board Serial Port Pin Assignment DB9 Male v 5 RS 232 RS 485 2W DCD RxD TxD D DTR D GND GND DSR RTS CTS OJIN AJA HRI WIN rR Block Diagram MiiNePort E2 FLASH SDRAM 2MB AME h 10100 MOXA 3 34 1 4W Resel Reset Reset Device UART 3 3 to5 VDC 1 8 MiiNePort E2 Introduction LED Indicators MiiNePort Evaluation Board Power LED Power LED D14 shows the status of the power input Ready LED D15 shows the status indicated in the following table Status Description Off 1 Power is off 2 Power error condition exists 3 System error
37. Function View Help A 2 a x EN Exit i Seach Search IP Locate Console j LAN2 MAC Address LAN2 IP Address Status MiiNePort E2 Utility Console and Driver I nstallation 2 The Searching window indicates the progress of the search Searching for NPort Ww Stop Found 1 NPort s 9 second s left No Model LAN1 MAC Address LAN1 IP Address LAN2 MAC Address LANZIP Address 1 MiNePort E2 00 90 E8 00 07 73 192 168 127 254 3 When the search is complete all MiiNePort E2 modules that were located will be displayed in the NPort Search Utility window V NPort Search Utility DER File Function View Help F 2 2 ES E 5 Exit Search Search IP Locate Console Model LAN MAC Address LANT IP Address LAN2 MAC Address LAN2 IP Address Status MiiNePort E2 00 90 E8 00 07 79 192 168 127 254 Search Result 1 NPort s 4 To modify the configuration of the highlighted MiiNePort E2 click the Console icon to open the web console This will take you to the web console where you can make configuration changes Refer to Chapter 7 Web Console Configuration for information on how to use the web console ATTENTI ON If you are looking for information related to TCP Server TCP Client Ethernet Modem RFC2217 or UDP modes you can ignore the following Driver sections including NPort Windows Driver Manager and Linux Real TTY Driver and instead jump directly to Chapter
38. MiiNePort 1GSB0115200 MiiNePort reports Baud rate as 115200 Data bits Command code SD Command parameters Port index Reply parameters MiiNePort s Data bits GSD1 System requests port 1 s Data bits for this MiiNePort 1GSD0O8 MiiNePort reports Data bits as 8 Stop bits Command code SS Command parameters Port index Reply parameters MiiNePort s stop bits index Stop Bits Index Table 0 Stop bits is 1 Stop bits is 1 5 2 Stop bits is 2 GSS1 System requests port 1 s Stop bits for this MiiNePort IGSS00 MiiNePort reports Stop bits as 1 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Parity Command code SP Command parameters Port index Reply parameters MiiNePort s Parity index as follows None Odd Even Mark Space B W N R O 2GSP1 System requests port 1 s Parity for this MiiNePort IGSP00 MiiNePort reports Parity as None Flow control Command code SL Command parameters Port index Reply parameters MiiNePort s Flow control index as follows 0 None 1 RTS CTS 2 XON XOFF 3 DTR DSR GSL1 System requests port 1 s Flow control for this MiiNePort IGSLO1 MiiNePort reports Flow control as RTS CTS FIFO Command code SF Command parameters Port index Reply parameters 1 Enable or
39. MiiNePort s Netmask address RNMe System requests Netmask address for this MiiNePort RNMO255 255 255 0 MiiNePort reports netmask as 255 255 255 0 A 37 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Gateway Command code NG Command parameters N A Reply parameters MiiNePort s Gateway address RNG System requests Gateway address for this MiiNePort RNMO255 255 255 255 MiiNePort reports Gateway address as 255 255 255 255 DNS Command code ND Command parameters The index 1 or 2 of DNS server Reply parameters MiiNePort s DNS address RND1 System requests DNS server 1 address for this MiiNePort IRNDO192 168 1 2 MiiNePort reports DNS server 1 address as 192 168 1 2 PHY Speed Command code NS Command parameters N A Reply parameters MiiNePort s PHY speed as follows 0 PHY auto negotiation is enabled 10 PHY speed is forced to 10Mbps with half duplex 11 PHY speed is forced to 10Mbps with full duplex 100 PHY speed is forced to 100Mbps with half duplex 101 PHY speed is forced to 100Mbps with full duplex RNS System requests PHY speed setting for this MiiNePort IRNSOO MiiNePort reports PHY speed is determined by PHY auto negotiation function Enable Disable SNMP Command code MS Command parameters N A Reply parameters 1 Enable or 0 Disable MiiNeP
40. NPort Select From List Mapping IPv6 COM Port f Search Select All Clear All Model MAC 1 Address 1 Address 2 1 MiiNePort E2 00 90 8 00 07 79 192 168 127 254 O Input Manually ee RealCOM Redundant COM Reverse RealCOM Y OK X Cancel 4 Alternatively you can select Input Manually and then manually enter the MiiNePort E2 module s IP Address 1st Data Port 1st Command Port and Total Ports to which COM ports will be mapped Click OK to proceed to the next step Note that the Add NPort page supports FQDN Fully Qualified Domain Name in which case the IP address will be filled in automatically Add NPort O Select From List No Model MAC 1 Address 1 Address 2 1 MiiNePort E2 00 90 E8 00 07 79 192 168 127 254 Input Manually RealCOM Redundant COM Reverse RealCOM First Mapping Port NPort IP Address 192 168 127 254 Data Port 350 Command Port 966 7 Total Ports 1 2 Help MiiNePort E2 Utility Console and Driver I nstallation 5 6 COM ports and their mappings will appear in blue until they are activated Activating the COM ports saves the information in the host system registry and makes the COM port available for use The host computer will not have the ability to use the COM port until the COM ports are activated Click Yes to activate the COM ports at this time or click No to activate the COM ports later NPort Windows Driver Manager
41. Network Settings in the navigation panel the main window will show a page of network settings that you can configure You must click on the Submit button to keep your configuration changes The Submit button will be located at the bottom of every page that has configurable settings If you navigate to another page without clicking the Submit button your settings will not be retained Changes will not take effect until they are saved and the module is restarted You may complete this in one step by clicking on Save Restart after you submit a change If you restart the module without saving your configuration the module will discard all submitted changes 3 Main Menu Go 3 Save Configuration OK verview 13 Basic Settings Your configuration has been saved and your settings will take effect when the server is restarted Click on Restart to reboot the MiiNePort E2 server now Advanced Settings E Maintenance Back J Restart Home Basic Settings Network Settings E Main Menu p 3 Network Settings Overview EMAY Basic Settings Device name MiiNePort IP configuration Static v Serial Port Settings IP address 192 168 127 254 1 Operation Modes Netmask 255 255 255 0 EJ Advanced Settings Gateway 4 Maintenance Save and Restart DNS server 1 DNS server 2 You must assign a valid IP address to the module before it will work in your network environment Your network system administrator should
42. Next gt Cancel 6 2 MiiNePort E2 Utility Console and Driver I nstallation 5 The installer will display a summary of the installation options Click Install to begin the installation The setup window will report the progress of the installation To change the installation settings click Back and navigate to the previous screen 1 Setup NPort Search Utility Ready to Install Setup is now ready to begin installing NPort Search Utility on your computer Click Install to continue with the installation or click Back if you want to review or change any settings Destination location C Program Files NPortSearch 12 Setup NPort Search Utility Completing the NPort Search Utility Setup Wizard Setup has finished installing NPort Search Utility on your computer The application may be launched by selecting the installed icons Click Finish to exit Setup NPort Search Utility Configuration The Broadcast Search function is used to locate all MiiNePort E2 modules that are connected to the same LAN as your computer After locating a MiiNePort E2 you will be able to change its IP address Since the Broadcast Search function searches by MAC address and not IP address all MiiNePort E2 modules connected to the LAN will be located regardless of whether or not they are part of the same subnet as the host 1 Start the NPort Search Utility and then click the Search icon FQ NPort Search Utility Os Eile
43. Serial Signals TTL TxD RxD RTS CTS DTR DSR DCD RST reset circuit GND Digital 1 O Pins GPIO 4 programmable I O pins 1 4 MiiNePort E2 Introduction Software Network Protocols ICMP ARP IP TCP UDP DHCP HTTP SNMP V1 SMTP TFTP Auto IP Telnet BOOTP Configuration Options Web Console Serial Console Serial Command Mode Telnet Console Windows Utility Windows Real COM Drivers Windows 95 98 ME NT 2000 Windows XP 2003 Vista 2008 7 x86 x64 Embedded CE 5 0 6 0 XP Embedded Fixed TTY Drivers SCO Unix SCO OpenServer UnixWare 7 SVR 4 2 QNX 4 25 QNX 6 Solaris 10 FreeBSD AIX 5 x Linux Real TTY Drivers Linux kernel 2 4 x 2 6 x Operation Modes Real COM TCP Server TCP Client UDP Ethernet Modem RFC2217 MCSC Environmental Limits Operating Temperature Standard Models 0 to 55 C 32 to 131 F Wide Temp Models 40 to 85 C 40 to 185 F Operating Humidity 5 to 95 RH Storage Temperature 40 to 85 C 40 to 185 F Power Requirements Input Voltage 3 3 or 5 VDC 5 Power Consumption 140 mA 3 3 VDC max 92 mA 5 VDC input max Regulatory Approvals FCC Part 15 Class B EMS EN55022 EN55024 EN61000 3 2 EN61000 3 3 EC61000 4 2 EC61000 4 3 1EC61000 4 4 1EC61000 4 5 EC61000 4 6 IEC61000 4 8 1EC61000 4 11 Shock 500 g s for non operational shock Vibration 20 g s for non operational vibration Warranty Warranty Period 5 years Details See www moxa com warranty 1 5
44. TCP alive check time Inactivity time Max connection Ignore jammed IP Allow driver control Local TCP port Command port Data Packing Packet length Delimiter 1 Delimiter 2 Delimiter process Force transmit TCP Server Mi 7 0 99 min 0 0 65535 ms 1y Enable Disable Enable Disable 4001 966 0 0 1024 00 Hex Enable 00 Hex Enable Do nothing 0 0 65535 ms Before reading this section refer to Chapter 3 Choosing the Proper Operation Mode to select the operation mode that best fits your device application Click Operation Modes located under the Main Menu to display the operating settings for both of MiiNePort s serial ports Disable Mode amp Main Menu OO Overview E3 Basic Settings Network Settings Serial Port Settings Operation Modes 9 Advanced Settings HE Maintenance Save and Restart Operation Modes Mode Disable vij When Operation mode is set to Disable that particular port will be disabled Check Apply the above settings to all serial ports to apply this setting to all ports Real COM Mode amp Main Menu E Overview H Basic Settings Network Settings Serial Port Settings da Operation Modes 9 Advanced Settings E Maintenance a Save and Restart ATTENTION To use Real COM mode refer to Chapter 6 Utility Console and Driver nstallation to install the Real COM Operation Modes Mode TCP alive check time Max connection Ignore jammed I
45. Tools 2 Change Password Load Factory Default Y Save and Restart Firmware Upgrade 11 Warning Note Upgrade firmware will discard your un saved configuration changes and restart the system Select firmware file The MiiNePort E2 s firmware can be upgraded though the web console or through NPort Search Utility If you have made any changes to your configuration remember to save the configuration first before upgrading the firmware Refer to the Save Configuration section in this chapter for more information Any unsaved changes will be discarded when the firmware is upgraded To upgrade the firmware simply enter the file name and click Submit The latest firmware can be downloaded from www moxa com 7 28 MiiNePort E2 Web Console Configuration Configuration Tools The MiiNePort E2 has Auto Configuration Configuration Import and Configuration Export functions built in to make the configuration process more efficient Auto Configuration You can enable or disable the AutoCFG Auto Configuration function here AutoCFG is designed for enabling automatic network configuration during your device production By using the AutoCFG you can realize true device mass production without needing to set up the network modules one by one amp Main Menu Overview EA Basic Settings EM Advanced Settings EA Maintenance 4 Console Settings EXSY Configuration Tool 2 Auto Configuration A Configuration Import A Configur
46. amp Main Menu E Overview Operation Modes E Basic Settings Mode UDP Y Network Settings Destination address 1 Begin End Port 4001 Serial Port Settings Destination address 2 Begin End Port 4001 AU Operation Modes Destination address 3 Begin End Port 4001 HU Advanced Settings Destination address 4 Begin End Port 4001 S Maintenance Local listen port 4001 Save and Restart 7 Data Packing Packet length D 0 1024 Delimiter 1 00 Hex Enable Delimiter 2 oo Hex Enable Delimiter process Do nothing Force transmit 0 0 65535 ms Destination I P address 1 Setting Factory Default Necessity IP address range Begin Empty Required E g Begin 192 168 1 1 End Empty End 192 168 1 10 Port 4001 Destination I P address 2 3 4 Setting Factory Default Necessity IP address range Begin Empty Optional E g Begin 192 168 1 11 End Empty End 192 168 1 20 Port 4001 Local listen port Setting Factory Default Necessity 1 to 65535 4001 Required The UDP port that the MiiNePort E2 listens to and that other devices must use to contactthe MiiNePort E2 To avoid conflicts with well known UDP ports the default is set to 4001 MiiNePort E2 Web Console Configuration Packing length Setting Factory Default Necessity 0 to 1024 0 Optional Default 0 The Delimiter Process will be followed regardless of the length of the data packe
47. and Driver I nstallation NPort Search Utility Installing NPort Search Utility 1 Click the INSTALL UTILITY button in the MiiNePort E2 Installation CD to install NPort Search Utility Once the program starts running click Yes to proceed 2 Click Next when the Welcome screen opens to proceed with the installation a Setup NPort Search Utility Welcome to the NPort Search Utility Setup Wizard This will install NPort Search Utility Yer1 10 0 on your computer It is recommended that you close all other applications before continuing Click Next to continue or Cancel to exit Setup 3 Click Browse to select an alternate location and then click Next to install program files to directory displayed in the input box 18 Setup NPort Search Utility Select Destination Location Where should NPort Search Utility be installed O Setup will install NPort Search Utility into the following folder To continue click Next If you would like to select a different folder click Browse Browse Atleast 1 3 MB of free disk space is required lt Back Next gt Cancel 4 Click Next to install the program s shortcuts in the appropriate Start Menu folder 1G Setup NPort Search Utility Select Additional Tasks Which additional tasks should be performed Select the additional tasks you would like Setup to perform while installing NPort Search Utility then click Next Additional icons lt Back
48. channel is a channel that is operating in digital input mode a DO channel is a channel that is operating in digital output mode You may use the evaluation board s Digital Output LEDs and Digital Input DIP switches as the digital input and output devices or you may connect digital input output devices to the DI O Terminal Block ATTENTI ON When using a digital input device connected to the DI O Terminal Block the corresponding Digital Input DIP switch must be set to OFF or High Setting the DIP switch to ON or Low will interfere with the signal from your digital input device For channels in digital output mode Low and High status is controlled from within the web console When using a Digital Output LED as your output device Low status will be expressed by the LED lighting up and High status will be expressed by the LED turning off Schematic Design Guide For guidance and suggestions on integrating your device s hardware with the MiiNePort E2 refer to the MiiNePort E2 Schematic Design Guide in our Document and Software CD 2 4 3 Choosing the Proper Operation Mode In this section we describe the various operation modes of MiiNePort E2 modules Depending on your intended use you can choose the best operation mode for serial communication over the network There is an operation mode for COM port mapping from the host computer as well as operation modes for TCP IP protocols After
49. end A sends 3 bytes of data 11 22 33 using channel 1 and 3 bytes of data 44 55 66 using channel 2 On the other side end B sends 6 bytes of data 33 22 11 11 22 33 using channel 1 and 6 bytes of data 66 55 44 44 55 66 using channel 2 Channel Enquiry Command DLE ENQ 0x10 0x05 This command is used for an end to query for its active reception channel By receiving this command the other end will resend a Channel Switch Command to indicate the active transmission channel it is dealing with which is the active reception channel the initiator of Channel Enquiry Command deals with Example A gt 10 05 B gt 10 01 01 This examples shows that end A queries for the active transmission channel of end B end B replies for channel 2 and then continues to send 3 bytes of data 11 22 33 using channel 2 Data Escape Command 0x10 0x10 This is not actually an MCSC command Since the DLE character is used by MCSC to escape its commands a pair of DLEs will be transmitted to indicate a single 0x10 character of data Example A gt 10 o1 Joo B gt This examples shows that end A sends 10 bytes of data 00 02 04 06 08 OA OC OE 10 12 using channel 1 Abnormal Packets Once the MiiNePort E2 receives a data stream with a header DLE character followed by characters that are not SOH ENG or DLE characters the
50. files from the tar file by executing the command tar xvf moxattyd tar The following files will be extracted README TXT moxattyd c source code moxattyd cf an empty configuration file Makefile makefile VERSION TXT fixed tty driver version FAQ TXT 4 Compile and Link For SCO UNIX make sco For UnixWare 7 make svr5 For UnixWare 2 1 x SVR4 2 make svr42 Configuring the UNI X Driver Modify the configuration The configuration used by the moxattyd program is defined in the text file moxattyd cf which is in the same directory that contains the program moxattyd You may use vi or any text editor to modify the file as follows ttyp1 192 168 1 1 950 For more configuration information view the file moxattyd cf which contains detailed descriptions of the various configuration parameters NOTE The Device Name depends on the OS See the Device Naming Rule section in README TXT for more information Start the moxattyd daemon that you configured in moxattyd cf If you would like to set the connection timeout you can add a t min parameter to specify the connection timeout value in minutes For example usr etc moxattyd moxattyd t 1 6 10 MiiNePort E2 Utility Console and Driver Installation NOTE You will now be able to use tty which is configured in moxattyd cf To start the moxattyd daemon after system bootup add an entry into etc inittab with the tty name you c
51. function and set the send period the MiiNePort will periodically send broadcast packets at the specified time interval Auto IP Report When the module is used in a dynamic IP environment additional time must be spent on IP management tasks For example when a module is operating as a server TCP Server or UDP modes a PC operating as a client will need to know the module s IP address If the DHCP server assigns a new IP address to the module the PC must have some way of obtaining the module s new IP address The IP Address report fields are used to set up periodic reporting of the module s IP address when the module s IP address is assigned by a server The IP address report is sent automatically at regular intervals to an IP address and TCP port number of your choice Auto IP Report allows you to view the module s IP address report on a PC To develop software that parses the IP address report data refer to Appendix C Auto IP Report Protocol for details on how to parse the module s IP address report data Auto report to Setting Factory Default Necessity E g 192 168 1 1 or URL IP None Optional addresses of the form x x x 0 and X X X 255 are invalid Auto report to TCP port Setting Factory Default Necessity E g 4001 4002 Optional 7 27 MiiNePort E2 Web Console Configuration If left blank auto IP reporting is disabled If an IP address is entered along with a TCP port num
52. hosts Ethernet data is sent on a first in first out basis to the serial port when data comes into the MiiNePort E2 from the Ethernet interface Ignore jammed IP Setting Factory Default Necessity Enable Disable Disable Optional Previously when Max connections gt 1 and the serial device is transmitting data if any one of the connected hosts is not responding it will wait until the data has been transmitted successfully before transmitting the second group of data to all hosts Currently if you select Yes for Ignore jammed IP the host that is not responding will be ignored but the data will still be transmitted to the other hosts Allow driver control Setting Factory Default Necessity Enable Disable Disable Optional If max connection is greater than 1 the MiiNePort E2 will ignore driver control commands from all connected hosts However if you set Allow driver control to YES control commands will be accepted Note that since the MiiNePort E2 may get configuration changes from multiple hosts the most recent command received will take precedence Local TCP port Setting Factory Default Necessity 1 to 65535 4001 Required The Local TCP port is the TCP port that the MiiNePort E2 uses to listen to connections and that other devices must use to contact the MiiNePort E2 To avoid conflicts with well known TCP ports the default is set to 4001
53. module continues to wait for a delimiter The Force transmit field allows you to specify the maximum amount of time that the module will wait for data With Force transmit enabled the module will automatically pack the data in the buffer for network transmission if no data is received for the specified time When set to 0 Force transmit is disabled which means there is no time limit for how long the module will wait to receive data When set between 1 and 65535 the module will pack data as soon as there is no serial communication for the specified time The optimal force transmit time depends on your application but it should be larger than one character interval within the specified baud rate to have any effect For example assume that the serial port is set to 1200 bps 8 data bits 1 stop bit and no parity In this case the total number of bits needed to send one character is 10 bits and the time required to transfer one character is 10 bits 1200 bits s x 1000 ms s 8 3 ms Since it requires about 9 ms to send one character the Force transmit should be 10 ms or more to have any effect At 9 ms or less the module will simply pack every character as it is received which would be the same as if no delimiter characters or Force transmit time were specified at all RFC 2217 Mode 3 Main Menu E Operation Modes E Overview E Basic Settings Mode RFC2217 v Network Settings TCP alive check time 7 0 99 min Serial Port Settin
54. nene nan nhen nena rnnnnrnnnnrnnnnrnnnnrnnnnrnnanencnnenos F 1 1 Introduction The MiiNePort E2 Series embedded device servers are compact drop in modules that can be integrated with your serial devices to enable connectivity to an Ethernet network All MiiNePort E2 Series modules come equipped with built in TCP IP protocols and other easy to use network enabling tools for fast integration allowing you to provide network access to any electronic device with a serial port The following topics are covered in this chapter Overview Package Checklist Product Features Product Specifications MiiNePort E2 Module Dimensions 00900000 Panel Layout and Pin Assignments gt Evaluation Board Layout gt Pin Assignments a Block Diagram O LED Indicators MiiNePort E2 Introduction Overview Moxa s MiiNePort E2 embedded device servers are designed for manufacturers who want to add sophisticated network connectivity to their serial devices with minimal integration effort The MiiNePort E2 is empowered by the MiiNe Moxa s second generation SoC which supports 10 100 Mbps Ethernet and up to 921 6 Kbps serial baudrate MiiNePort E2 is built with a versatile selection of ready to use operation modes and requires only a small amount of power By using Moxa s innovative NetEZ technology the MiiNePort E2 can be used to convert any device with a standard serial interface to an Ethernet enabled device in no time In addition the MiiNePort
55. of the serial port of the MiiNePort E2 to Real COM mode After logging in as a super user enter the directory usr lib npreal2 driver and then execute mxaddsvr to map the target MiiNePort E2 serial port to the host tty ports The syntax of mxaddsvr is as follows mxaddsvr MiiNePort E2 I P Address Total Ports Data port Cmd port The mxaddsvr command performs the following actions 1 Modifies npreal2d cf 6 8 MiiNePort E2 Utility Console and Driver Installation 2 Creates tty ports in directory dev with major and minor number configured in npreal2d cf 3 Restarts the driver Mapping tty ports automatically To map tty ports automatically you may execute mxaddsvr with just the IP address and number of ports as in the following example cd usr lib npreal2 driver mxaddsvr 192 168 3 4 16 In this example 16 tty ports will be added all with IP 192 168 3 4 with data ports from 950 to 965 and command ports from 966 to 981 Mapping tty ports manually To map tty ports manually you may execute mxaddsvr and manually specify the data and command ports as in the following example cd usr lib npreal2 driver mxaddsvr 192 168 3 4 16 4001 966 In this example 16 tty ports will be added all with IP 192 168 3 4 with data ports from 4001 to 4016 and command ports from 966 to 981 Removing Mapped TTY Ports After logging in as root enter the directory usr lib npreal2 driver and then ex
56. packing process is executed successfully and the packed file can be found in the same directory MOXA EZPageTool Version 1 6 o KB Packing qu EZPage jar 716 KB Packing index htm r 24 KB pack file success yi 288 KB Step 3 Upload EZPage to the MiiNePort There are three ways to upload EZPage to MiiNePort 8 9 MiiNePort E2 NetEZ Technologies You can use EZPageTool to upload EZPage Execute the EZPageTool command updatefs parameter to upload EZPage to the MiiNePort in command prompt mode Usage EZPageTool updatefs file to upload device IP Example updatefs ezpage 192 168 35 101 You will see the following message if the upload process is executed successfully MOXA EZPageTool Version 1 6 upload web image file success You can combine EZPage and MiiNePort s firmware in one file and upload it via the NPort Search Utility Execute the EZTool command with combine parameter to combine EZPage and firmware in the command prompt mode Usage combine file name of EZPage file name of firmware file name after combination Example combine ezpage E2 rom e2_ezpage rom You will see the following message if the combination process is executed successfully MOXA EZPageTool Version 1 68 Combine web image into firmware success The file can be found in the same directory 1KB 716KB 34 KB 288 KB 632 KB Execute the NPort Search Utility and select the combined firmware file to uploa
57. provide you with an IP address and related settings for your network The IP address must be unique within the network otherwise the module will not have a valid connection to the network First time users can refer to Chapter 5 Initial IP Address Configuration for more information Device Name Setting Factory Default Necessity 1 to 39 characters model name _ Serial No Optional This option can be used to specify the location or application of the module which may be useful when managing more than one module on the network 7 3 MiiNePort E2 Web Console Configuration IP configuration Method Function Definition Static User defined IP address Netmask Gateway DHCP DHCP Server assigned IP address Netmask Gateway DNS DHCP BOOTP DHCP Server assigned IP address Netmask Gateway DNS or BOOTP Server assigned IP address BOOTP BOOTP Server assigned IP address AUTOIP AUTOIP protocols automatically negotiate and assign IP in 169 254 16 network IP configuration is a required field The default setting is Static ATTENTION In Dynamic IP environments the module will attempt to obtain an IP address from the DHCP or BOOTP server 3 times at 30 second intervals The timeout for the first try will be 1 second the second try will be 3 seconds and the last try will be 5 seconds If the DHCP BOOTP Server is unavailable the module will use the default IP address 192 168 127 254
58. restart the module Model name MiiNePort E2 Serial No 779 Device name MiiNePort Firmvare version 1 0 Build 10060317 Ethernet MAC address 66 96 E8 06 07 79 K lt Main Menu gt gt lt a gt 4D 2 gt lt 3 lt 4 gt lt 5 gt 1d lt 7 lt 8 gt lt a gt lt c gt lt 1 gt lt m gt lt p gt Cu Cs gt lt q gt Network settings Serial settings Operation mode settings Accessible IP list SNMP agent DIO settings Serial command mode settings Miscellaneous Console settings Configuration tools Change password Load factory default Monitor Ping View settings Save and restart Quit Key in your selection Ready to restart Cy lt n gt Yes No Key in your selection 5 6 6 Utility Console and Driver Installation This chapter teaches you how to install the MiiNePort E2 s utilities use the utilities to perform simple configurations and install the drivers The following topics are covered in this chapter O NPort Search Utility gt Installing NPort Search Utility gt NPort Search Utility Configuration O NPort Windows Driver Manager gt Installing NPort Windows Driver Manager gt Using NPort Windows Driver Manager O The Linux Real TTY Driver gt Mapping TTY Ports gt Removing Mapped TTY Ports gt Removing Linux Driver Files O The UNIX Fixed TTY Driver gt Installing the UNIX Driver gt Configuring the UNIX Driver MiiNePort E2 Utility Console
59. s serial port After that the MiiNePort E2 immediately enters data mode Dial out The MiiNePort E2 accepts the AT command ATD lt IP gt lt TCP port gt from the serial port and then requests a TCP connection from the remote Ethernet Modem or PC This is where lt I P gt is the IP address of the remote Ethernet modem or PC and lt TCP port gt is the TCP port number of the remote Ethernet modem or PC Once the remote unit accepts this TCP connection the MiiNePort E2 will send out the CONNECT lt baud gt signal via the serial port and then enter data mode Disconnection request from local site When the MiiNePort E2s is in data mode the user can drive the DTR signal to OFF or send from the local serial port to the MiiNePort E2 The MiiNePort E2 will enter command mode and return NO CARRIER via the serial port and then input ATH to shut down the TCP connection after 1 second The command cannot be divided The character can be changed in register S2 and the guard time which prefixes and suffixes the in order to protect the raw data can be changed in register S12 7 20 MiiNePort E2 Web Console Configuration Disconnection request from remote site After the TCP connection has been shut down by the remote Ethernet modem or PC the MiiNePort E2 will send the NO CARRIER signal via the serial port and then return to command mode AT Commands The MiiNePort E2 supports the following common AT commands u
60. set to output mode 10 Data 0 1 2nd DIO channel to be written 0 set to low 1 set to high 11 Data 0 1 3rd DIO channel to be written optional 0 set to input mode 1 set to output mode 12 Data 0 1 3rd DIO channel to be written optional 0 set to low 1 set to high 13 Data 0 1 4th DIO channel to be written optional 0 set to input mode 1 set to output mode 14 Data 0 1 4th DIO channel to be written optional O set to low 1 set to high This command writes the status of a range of DIO channels specified in bytes 5 and 6 The length of the command depends on the number of channels to be written For example the 10 byte command 6 2 0 6 0 1 0 0 1 1 requests DIO O be set to digital input mode and low status and DIO 1 be set to digital output mode and high status If you wanted to include a change of DIO 2 to digital output mode and low status the 12 bye command sequence would be 6 2 0 8 0 2 0 0 1 1 1 0 Response Byte Descriptor Value Description 1 Header 6 command number fixed 2 Header 2 version fixed 3 Header 0 1 2 3 command status error code 0 okay 4 5 6 OXFF D 6 MiiNePort E2 DIO Commands 4 Header 4 6 8 data length depends on the number of DIO channels requested 5 Data 0 1 1st requested DIO channel 0 channel has been changed to input mode 1 channel has been changed to output mode 6 Data 0 1 1st requested DIO channel 0
61. the single physical serial channel and dispatches the data received from the physical serial channel to the appropriate applications With the help of the MCSC modules the two applications at opposite ends are still connected to a logical bi directional channel but two or more application pairs are also connected by separate channels to the physical serial channel The communication model is depicted in the following figure TCP Communication 2 TCP Communication 1 wa sks Bulo1quo 10 gt L 0 un O 2 gt 0 a po iJ xe Lo 0 Q W Serial Communication The MCSC module is built into the MiiNePort E2 To enable MCSC you need to set your MiiNePort E2 serial port operation mode to MCSC mode and then set the channels operation mode individually according to your application In addition you also need to implement the MCSC module in your device s main system MiiNePort E2 NetEZ Technologies The following basic principles apply to all MCSC module implementations 1 MCSC uses a command based stream protocol That is transmissions that do not fit the MCSC command format are treated as application data All MCSC commands begin with ASCII DLE characters For the detailed command format refer to the Command Packets section in following section 2 Other than dealing with MCSC commands an MCSC module simply transfers application data from the upper application channel to the underlying physical serial c
62. to 4001 MCSC Mode 3 Main Menu as i Operation Modes LJ Overview EY Basic Settings Mode MCSC v Network Settings Channel 1 Disable Modify Serial Port Settings Channel 2 Disable Operation Modes 9 Advanced Settings EJ Maintenance Save and Restart After MCSC mode is selected you will see 2 channels that are ready to configured Under the MCSC structure each channel works independently so you need to configure each channel separately according to your application Click Modify to configure the Channel 1 7 22 MiiNePort E2 Web Console Configuration Operation Modes Channel 1 Mode Real COM _ TCP alive check time 7 0 99 min Max connection 11 a Ignore jammed IP Enable Disable Allow driver control Enable Disable Data Packing Packet length o 0 1024 Delimiter 1 jag Hex Cl Enable Delimiter 2 00 Hex Enable Delimiter process Do nothing Force transmit D 1 0 65535 ms After you click Modify the channel configuration window will pop up and you will see exactly the same configuration options as stated earlier in this chapter For example if you want to set Channel 1 to TCP Client mode just finish your configuration click Submit and a confirmation window will appear Operation Modes Settings OK Click the Close button to return to the Operation Mode configuration screen to finish configuring your Channel 2 After you get back to the screen you will see the TCP mode sett
63. to send a series of characters in the same packet the serial device attached to the MiiNePort E2 should send that series of characters during a time interval less than the Force transmit timeout for the MiiNePort E2 and the total length of data must be less than or equal to the MiiNePort E2 s internal buffer size The serial communication buffer size for the MiiNePort E2 is 1 KB per port Ethernet Modem Mode NOTE amp Main Menu N Operation Modes LI Overview EA Basic Settings Mode Ethernet Modem A Network Settings TCP alive check time 7 0 99 min Serial Port Settings Local TCP port 4001 Operation Modes E Advanced Settings g E Maintenance Save and Restart Dial in The MiiNePort E2 listens for a TCP IP connection request from the remote Ethernet modem or host The MiiNePort E2 s response depends on the ATSO value as outlined below ATSO 0 default The MiiNePort E2 will temporarily accept the TCP connection and then send the RING signal out through the serial port The serial controller must reply with ATA within 2 5 seconds to accept the connection request after which the MiiNePort E2 enters data mode If the ATA command is not received the MiiNePort E2 will disconnect after sending three RING signals ATSO21 The MiiNePort E2 will accept the TCP connection immediately and then send the CONNECT lt baud gt command to the serial port in which lt baud gt represents the baudrate of the MiiNePort E2
64. 0 Disable MiiNePort s FIFO GSF1 System requests port 1 s FIFO for this MiiNePort IGSFO1 MiiNePort reports FIFO as Enable MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Interface Command code SI Command parameters Port index Reply parameters O RS232 or 1 RS485 2wire MiiNePort s Interface GSI1J System requests for port 1 s interface for this MiiNePort GSIO1J MiiNePort reports interface is RS485 2wire Operation Mode Command code OM Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For the port itself channel index is 0 Reply parameters MiiNePort s operation mode index as shown in the following table 0 Disable 1 Real COM 2 RFC2217 3 TCP server 4 TCP client 5 UDP 6 e modem 7 MCSC This value is unavailable for MCSC channels GOM1 0d System requests for port 1 s Operation Mode for this MiiNePort GOM04 MiiNePort reports Operation Mode is TCP client GOM1 2 When port 1 is set to MCSC system requests for the operation mode for channel 2 of port 1 GOMO2J MiiNePort reports operation mode is RFC2217 Data Packing Length Command code OL Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0
65. 001 A 2a setongs Destination IP address 4 Port 4001 A Serial Command Mode 5 FS Designated local port 1 5011 0 65535 0 represents assigned automatically BS Miscellaneous 5 Eig Maintenance Designated local port 2 5012 0 65535 da eva dineStare Designated local port 3 5013 0 65535 Designated local port 4 5014 0 65535 Connection control Startup None h Data Packing Packet length D 0 1024 Delimiter 1 00 Hex Enable Delimiter 2 00 Hex Enable Delimiter process Do nothing Force transmit D 0 65535 ms TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Optional 0 min TCP connection is not closed due to an idle TCP connection 1 to 99 min The MiiNePort E2 automatically closes the TCP connection if there is no TCP activity for the given time Inactivity time Setting Factory Default Necessity O to 65535 ms 0 ms Optional 0 ms TCP connection is not closed due to an idle serial line 0 65535 ms The MiiNePort E2 automatically closes the TCP connection if there is no serial data activity for the given time This parameter defines the maintenance status as Closed or Listen for the TCP connection The connection is closed if there is no incoming or outgoing data through the serial port during the specific Inactivity time If the Inactivity time is set to 0 the current TCP connection is kept active until a connection close request is
66. 2 SCM Serial Command Mode I EE EE EE I EI I I tintin nrnrnnnnes 8 2 AULOGEG AUTO Configuration mii AAA AAA yale 8 3 MCSC Multiple Channel Serial Communication s sssssssssrsssrrsssrrssrtrtrttt rrtt rnnt tnnt nunn Ennn Ennn Ennn EEEn nnn Ennan 8 4 Command Packets aasia aa at aaea A TALLA NEERA a A RRA caca tada AR 8 6 SCM Se al Command Mode Under MES xciccseccstccttcasscacscagacaencnascaaieuancatadadadaaiiaassaasdaascessaeaammmnanants 8 8 EZPad Ciastiaciddncaahanaabisatadaantatinanaadansaraaadaddantacrabaracrdadaiataradetadasadriadatataraderabasarnaadarataiaderatasadnsadandbaadeamie 8 8 How to Clean up EZPage in MiiIN POrt 0 ccc ene e nee eats 8 10 Introduction to SCM Serial Command Mode Command Set nccccccocacncncnonononanananananannnnnnrararacararacananas A 1 Command Reply EM a a ai asia da A 2 Command Code for Getting the ConNfiguratiON ooococccccccncoccnconnnnnnnnnnnnnnnnnnnnnn nn nn nnnnnnnn nn nn nn a nrnnnnrnnnnreranrnnnnss A 3 Command Code for Setting the Configuration cece eee nents A 19 Command Code for Retrieving Running Configuration ccece eee eee eee e eee tenets A 35 Command Code for Viewing the StatuS ccc nett ene EEEE EREE A 52 Control Command COWS state A 53 Well Known Port NUMberS cccccccceeeeeeeeeeeeeeueueueeeueueeeeeeeeeeeeueueueueueuauauauauauauauauauaeaeaeeeucueueueueueueuauanananae B 1 Auto IP Report Protocol cceccceeeeceeeeeeeeeeeeeeeeeee
67. 2 0 0 0 nn nn rra n nr rn tenant aetna 2 3 Connecting the POWer adie SALA A e 2 3 Connecting to the Network 0 nr rr e nena e ne taeee nae 2 3 Connecting toa Serial DeVICE miras riada rd sade sada rd dias 2 4 Digital 1 0 Channel SettingS nr niasa aa aa sands sa E E TE E 2 4 Schematic Design Guid amanda dad 2 4 3 Choosing the Proper Operation Mode ococoococoocncnonocannncnnnncnnnncnnnncnnnncnnnncnnnnrnnnnrnnnnrnnnnrnnnnrannnrananennanennas 3 1 OVERVIQW 2M Ainnd ie ei tad eo a a alee SON a Paula Tua wale eie Teale rund eile Suu ule uu died tule did Cu ust als eau a aly vais TaY 3 2 Real COM IMO cia cal cca wate al cease a or uta aac Dae Oat Dc a aca aaa a Ga Sian Pa ala ace aa ala a EEO 3 2 TEP Server MORE att E ada aan LLENA ean ent mene 3 2 TERCIO tana oran ada danaanadcnaaaadcdanaacac dina saae tana tecd canes A 3 3 REC2217 MOC iiss teta 3 4 UDR MOG AE ae ae haley E Cate E A ate AS EA vibe Dida eu vie E ene ora a 3 4 Ethernet Modem Modereer titi EEE reee rre 3 5 MCS iMod Brescia anodino ade ada dd tan id a tana tana An tid aha nian ater AL AnD LL E A T A 3 5 4 Choosing the Configuration Tool oomocnonocncnorncnonannnnncnnrncnnrnnnnrncnnrnnnnrnnnnrnnnnrnnnnrnnnnrnnnnrnnnnrnnnnrannnrananrass 4 1 A A o 4 2 Web a le A a a E tata 4 2 E A 4 3 SEMiSeriallcommand Moda catar raras iia 4 3 5 Initial IP Address ConfiguratiON oocmcmocncnornnnoracnnnncnnnncnnrncnnrncnnrnnnnrncnnrnnnnrncnnrnrnnrnrnnrnrnnrncnnrnranrncnnrncanans
68. 2 168 1 8 4001 System sets UDP destination address 3 is from 192 168 1 3 to 192 168 1 8 and port as 4001 for port 1 ISUDO MiiNePort reports command executed successfully A 32 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set UDP local listen port Command code UP Command parameters Port index MCSC channel index and local UDP port Parameters are separated by a semicolon For an MCSC disabled port the channel index is 0 Reply parameters N A SUP1 0 4001 System sets UDP local listen port as 4001 for port 1 ISUPO MiiNePort reports command executed successfully E modem TCP alive check time Command code EA Command parameters Port index MCSC channel index and TCP alive check time Every parameter is separated by semicolon For MCSC disabled port channel index shall be 0 Reply parameters N A SEA1 0 54 System sets port 1 s TCP alive check time as 5 for port 1 ISEAOJ MiiNePort reports command executed successfully E modem local listen port Command code EP Command parameters Port index MCSC channel index and TCP local port Every parameter is separated by semicolon For MCSC disabled port channel index shall be 0 Reply parameters N A SEP1 0 4100J System sets TCP port as 4100 for port 1 ISEPOJ MiiNePort reports command executed successfully DIO ini
69. 2 Load Factory Default 2 Change Password Save and Restart 7 29 MiiNePort E2 Web Console Configuration Change Password Click on Change Password in the navigation panel to display the Change Password window amp Main Menu ae E Change Password Overview Basic Settings Password Q Advanced Settings ENYA Maintenance Old password New password 4 Console Settings A Configuration Tool 2 Load Factory Default Change Password Save and Restart Confirm password Enter the old password and new passwords and click on Submit To remove password protection leave the new password blank and just enter the old password Load Factory Default To load the factory default settings click on Load Factory Default in the navigation panel and then click on Submit All previous modifications will be lost but you can choose to keep the IP settings by checking Keep IP settings amp Main Menu E Load Factory Default Overview Basic Settings Click on Submit to reset all settings including the console password to the factory default values EA Advanced Settings EX Maintenance A Console Settings Y EXA Configuration Tool 2 Load Factory Default 2 Change Password Save and Restart Reset to Factory Default Keep IP settings 7 30 3 NetEZ Technologies This chapter introduces the NetEZ technology family and its four innovative functions The following topics are
70. ARP is enable otherwise reply 0 RVAC System requests gratuitous ARP status for alert mail server IRVA1 300 MiiNePort reports gratuitous ARP as Enable and send period as 300 sec Serial Number Command code S Command parameters N A Reply parameters MiiNePort s serial number in digit notation R S System requests MiiNePort s serial number IR S09527 MiiNePort reports serial number is 9527 Firmware Version Command code V Command parameters N A Reply parameters MiiNePort s firmware version Version parts are separated by a single dot with at least two parts major minor and at most three parts major minor rev ROVe System requests MiiNePort s firmware version IRESO1 0 MiiNePort reports serial number is 9527 A 51 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Firmware Build Number Command code B Command parameters N A Reply parameters MiiNePort s firmware build number eight digits R Be System requests MiiNePort s firmware build number REB009021208 MiiNePort reports build number is 09021208 MAC address Command code M Command parameters N A Reply parameters MiiNePort s MAC address ROM System requests MiiNePort s firmware build number R MOOO 90 E8 71 00 10 MiiNePort reports MAC address is 00 90 E8 71 00 10 Command Cod
71. Accessible IP List Community string public A SNMP Agent Contact name A Pin and 10 Settings Serial Command Mode Miscellaneous EXA Maintenance a Save and Restart Location 7 24 MiiNePort E2 Web Console Configuration Community string Setting Factory Default Necessity 1 to 39 characters Public Optional E g support 886 89191230 300 A community name is a plain text password mechanism that is used to authenticate queries to agents of managed network devices Contact Name Setting Factory Default Necessity 1 to 39 characters None Optional E g support 886 89191230 300 The SNMP contact information usually includes an emergency contact name and telephone or pager number Location Setting Factory Default Necessity 1 to 39 characters None Optional E g floor 1 office 2 Enter a location string for SNMP agents This string is usually set to the street address where the module is physically located DI O Settings The DIO channel is configured on the DIO Settings page Use Mode to specify either digital input or digital output operation When digital input operation is selected the channel s status is controlled by an external digital switch When digital output operation is selected the channel transmits a high or low signal Use Status to control the high or low status for digital output channels The status setting will be igno
72. C Advanced Settings Stop bits 1 E ls a Maintenance Parity None E C Save and Restart Flow control RTS CTS S FIFO Enable O Disable Interface RS 422 RS 485 Y Port Alias Setting Factory Default Necessity 1 to 15 characters None Optional E g PLC No 1 This function is designed for future use You may enter a string to help in the module s serial port from other serial ports ATTENTI ON Refer to the serial communication parameters in your serial device s user s manual The module s serial parameters should be the same as the parameters used by your serial device Baud Rate Setting Factory Default Necessity 50 bps to 921 6 Kbps supports non standard baudrates 115 2 Kbps Required amp Main Menu A Overview EJ Basic Settings Network Settings Serial Port Settings Communication Parameters Port alias Serial Parameters Baud rate Hint 115200 Y Operation Modes Data bits ag Y E Advanced Settings Stop bits 1 amp 9 Maintenance Parity None 4 Save and Restart Flow control RTS CTs Mv FIFO Enable O Disable Interface RS 422 RS 485 Y Submit MiiNePort E2 Web Console Configuration MiiNePort E2 supports the Any Baud Rate non standard baud rate feature If your baud rate is not listed select Other from the drop down list and type the baud rate in the input box MiiNePort E2 will use the closest baud rate we can support amp Ma
73. COM Port Address 1 Address 2 Refer to Chapter 6 Utility Console and Driver I nstallation for details on how to use NPort Search Utility and NPort Windows Driver Manager Web Console After locating a MiiNePort E2 with NPort Search Utility you may configure the MiiNePort E2 using a standard web browser Refer to Chapter 7 Web Console Configuration for details on how to access and use the MiiNePort E2 web console amp Main Menu gt Welcome to MiiNePort web console E Overview E Basic Settings Model name MiiNePort E2 EN Advanced Settings Serial Ng 27a ch X Device name MiiNePort HE Maintenance Firmware version 1 0 Build 10060317 Save and Restart Ethernet IP address 192 168 127 254 Ethernet MAC address 00 90 E8 00 07 79 Up time D days 00h 02m 49s Serial communication nd Data Mode 4 2 MiiNePort E2 Choosing the Configuration Tool Telnet Console Your MiiNePort E2 can be configured over the network with Telnet which requires that the module has a network connection and an IP address We briefly discuss Telnet console configuration in Chapter 5 Initial I P Address Configuration All Telnet console commands are introduced in Chapter 7 Web Console Configuration Serial No Device name Firmware version Ethernet MAC addres K lt Main Menu gt gt lt B gt Network settings lt i gt Serial settings 2 gt Operation mode s MiiNePort 779 MiiNePort 1 60 Build 10068317 66 96 E8 66 67 79 ettings
74. DIO number int i len for i 0 i lt end start 1 1 packet data i 2 mode i packet data it 3 status i send SocketFd char amp packet end start 1 2 2 sizeof DIOHeaderStruct 0 Send TCP packet Process the returned data here SNMP Agent with MIB II and RS 232 Like Groups MiiNePort E2 Series modules have SNMP Simple Network Management Protocol agent software built in The software supports RFC1317 RS 232 like groups and RFC 1213 MIB II The following table lists the standard MIB II groups as well as the variable implementations for the MiiNePort E2 Series modules RFC1 213 MIB II supported SNMP variables System MIB Interfaces MIB IP MIB ICMP MIB SysDescr itNumber ipForwarding IcmpInMsgs SysObjectl D ifindex ipDefaultTTL IcmpInErrors SysUpTime ifDescr ipInreceives IcmpInDestUnreachs SysContact ifType ip nHdrErrors IcmpInTimeExcds SysName ifMtu ip nAddrErrors IcmpinParmProbs SysLocation ifSpeed ipForwDatagrams IcmpinSrcQuenchs SysServices ifPhysAddress ipInUnknownProtos IcmpInRedirects ifAdminStatus ipl nDiscards IcmpinEchos ifOperStatus ip nDelivers IcmplInEchoReps ifLastChange ipOutRequests IcmpInTimestamps ifl nOctets ipOutDiscards IcmpTimestampReps fl nUcastPkts ipOutNoRoutes IcmpInAddrMasks iffnNUcastPkts ipReasmTimeout IcmpOutMsgs ifInDiscards ipReasmReqds IcmpOutErrors ifl nErrors ipReasmOKs IcmpOutDestUnreachs ifInUnknown
75. F 0 for None Optional The Delimiter fields are used to specify a character or 2 character sequence which will act as a marker to control packing of serial data By default no delimiter characters are defined so the module transmits data as soon as it is received When a delimiter character or characters are defined the module will hold data in its buffer until it receives the delimiter character or 2 character sequence When the delimiter is received the module will pack up the data in its buffer and send it through the Ethernet port Use Delimiter 1 to define the first delimiter character in hex If only one delimiter character will be used Delimiter 2 should be set to 0 If the delimiter will be a two character sequence use Delimiter 2 to define the second character To disable the use of delimiters set both Delimiter 1 and Delimiter 2 to 0 Note that data packing is not only controlled by the delimiter it is also influenced by the module s buffer size and the Force transmit field If the delimiter has not been received by the time the 1K buffer is full the module will pack the data for network transmission and clear the buffer Also if the module will also pack data for network transmission if the next byte of data is not received within the Force transmit time Delimiter process Setting Factory Default Necessity Do Nothing Do Nothing only effective when Delimiter is enabled Optional Delimiter 1 D
76. MiiNePort E2 User s Manual First Edition J uly 2010 Www moxa com pr t MOXA 2010 Moxa Inc All rights reserved Reproduction without permission is prohibited MiiNePort E2 User s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement Copyright Notice Copyright 2010 Moxa Inc All rights reserved Reproduction without permission is prohibited Trademarks The MOXA logo is a registered trademark of Moxa Inc All other trademarks or registered marks in this manual belong to their respective manufacturers Disclaimer Information in this document is subject to change without notice and does not represent a commitment on the part of Moxa Moxa provides this document as is without warranty of any kind either expressed or implied including but not limited to its particular purpose Moxa reserves the right to make improvements and or changes to this manual or to the products and or the programs described in this manual at any time Information provided in this manual is intended to be accurate and reliable However Moxa assumes no responsibility for its use or for any infringements on the rights of third parties that may result from its use This product might include unintentional technical or typographical errors Changes are periodically made to the information herein to correct such errors and these changes a
77. MiiNePort E2 will see this as an abnormal data packet caused by communication problems and will drop this data packet without sending data out through the Ethernet port The MiiNePort E2 will return the channel enquiry command 10 05 to the serial main system through the serial channel helping the main system to detect and troubleshoot the problem 8 7 MiiNePort E2 NetEZ Technologies SCM Serial Command Mode under MCSC When MCSC is enabled a special application channel indexed as OxFF channel 256 is dedicated for Moxa SCM without additional configuration required SCM enables the controlling system to configure monitor or control the attached embedded device server For more information about what SCM can do refer to Chapter 3 Choosing the Configuration Tool With MCSC normal network communication continues uninterrupted when the controlling system is monitoring or diagnosing the embedded device server with SCM providing SCM with greater flexibility EZPage The MiiNePort E2 s EZPage is designed for creating a customized web page to fit specified control monitor of the serial device via web browser The MiiNePort creates a built in web server running with Java applet support that user can develop customized web pages on the MiiNePort EZPage is a java applet based program and you can refer or modify Moxa s web console example to develop specified web console easily The main entry point of this program is in srajanEZPage java
78. NPortDrvManager Start Menu folder NPort Windows Driver Manager e Install Cancel 6 Click Finish to complete the installation of NPort Windows Driver Manager je Setup NPort Windows Driver Manager Completing the NPort Windows Driver Manager Setup Wizard Setup has finished installing NPort Windows Driver Manager on your computer The application may be launched by selecting the installed icons Click Finish to exit Setup Using NPort Windows Driver Manager After you install NPort Windows Driver Manager you can set up the MiiNePort E2 s serial port which is connected to your device s main board as remote COM ports for your PC host Make sure that the serial port on your MiiNePort E2 is already set to Real COM mode when mapping COM ports with the NPort Windows Driver Manager NOTE Refer to Chapter 7 Web Console Configuration to learn how to configure your MiiNePort E2 to Real COM mode 1 Goto Start gt NPort Windows Driver Manager gt NPort Windows Driver Manager to start the COM mapping utility 2 Click the Add icon 4 NPort Windows Driver Manager File COM Mapping Configuration View Help i a E 7 Exit Add i d t No COM Port Address 1 Address 2 MiiNePort E2 Utility Console and Driver I nstallation 3 Click Search to search for the MiiNePort E2 modules From the list that is generated select the server to which you will map COM ports and then click OK Add
79. NS00 MiiNePort reports PHY speed determined by PHY auto negotiation function MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Enable Disable SNMP Command code MS Command parameters N A Reply parameters 1 Enable or 0 Disable MiiNePort s SNMP agent 2GMS System requests Enable Disable SNMP agent for this MiiNePort IGMSO1 MiiNePort reports SNMP agent as Enable Community String Command code MU Command parameters N A Reply parameters MiiNePort s SNMP Community string 2GMU System requests SNMP community string for this MiiNePort GMUOpublice MiiNePort reports SNMP community string as public Contact Name Command code MN Command parameters N A Reply parameters MiiNePort s SNMP Contact Name 2GMN System requests SNMP contact name for this MiiNePort GMNOs_namee MiiNePort reports SNMP contact name as s_name Location Command code ML Command parameters N A Reply parameters MiiNePort s SNMP Location GMLe System requests SNMP location for this MiiNePort GMLOs_locatione MiiNePort reports SNMP location as s_location MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Enable Disable Accessible IP List Command code AS Command parameters N A Reply parameters Enable 1 or Disable 0 MiiNePort s accessible IP list GAS System reque
80. NePort reports command executed successfully Stop bits Command code SS Command parameters Port index and stop bits separated by a semicolon MiiNePort s Stop bits index as shown in the following table 0 Stop bits is 1 Stop bits is 1 5 2 Stop bits is 2 Reply parameters N A SSS1 0 System sets port 1 s stop bits as 1 1ISSSO MiiNePort reports command executed successfully Parity Command code SP Command parameters Port index and parity separated by a semicolon MiiNePort s Parity index as shown in the following table 0 None 1 Odd 2 Even 3 Mark 4 Space Reply parameters N A SSP1 0 System sets port 1 s parity bit as None ISSPO MiiNePort reports command executed successfully A 25 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Flow control Command code SL Command parameters Port index and flow control separated by a semicolon MiiNePort s Flow control index as shown in the following table 0 None 1 RTS CTS 2 XON XOFF 3 DTR DSR Reply parameters N A SSL1 1 System sets port 1 s flow control as RTS CTS ISSLOC MiiNePort reports command executed successfully FIFO Command code SF Command parameters Port index and FIFO setting separated by a semicolon FIFO setting is 1 Enable
81. P Allow driver control Data Packing Packet length Delimiter 1 Delimiter 2 Delimiter process Force transmit Real COM M z 0 99 min 1 Enable Disable Enable _ Disable D 0 1024 00 Hex enable 00 Hex Enable Do nothing D 0 65535 ms driver on Windows or Linux 7 7 MiiNePort E2 Web Console Configuration TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Optional O min The TCP connection is not closed due to an idle TCP connection 1 to 99 min The module automatically closes the TCP connection if there is no TCP activity for the given time After the connection is closed the module starts listening for another host s TCP connection Max connection Setting Factory Default Necessity 1 2 3 4 1 Required Max connection is used when the device needs to receive data from different hosts simultaneously The factory default only allows 1 connection at a time When Max Connection is set to 1 the Real COM driver on the specific host has full control Max connection 1 The module will only allow 1 host s Real COM driver to open a connection to the module s serial port Max connection 2 to 4 When set to 2 or higher Real COM drivers for up to the specified number of hosts may open this port at the same time When Real COM drivers for multiple hosts open the port at the same time the COM driver only provides a pure data tunne
82. Ports are assigned by IANA and on most systems can only be used by system processes or by programs executed by privileged users The following table shows famous port numbers among the well known port numbers For more details visit the IANA website at http www iana org assignments port numbers TCP Socket Application Service 0 reserved 1 TCP Port Service Multiplexor 2 Management Utility 7 Echo 9 Discard 11 Active Users systat 13 Daytime 15 Netstat 20 FTP data port 21 FTP CONTROL port 23 Telnet 25 SMTP Simple Mail Transfer Protocol 37 Time Time Server 42 Host name server names server 43 Whois nickname 49 Login Host Protocol Login 53 Domain Name Server domain 79 Finger protocol Finger TCP Socket Application Service 80 World Wide Web HTTP 119 Network News Transfer Protocol NNTP 123 Network Time Protocol 213 PX 160 223 Reserved for future use MiiNePort E2 Well Known Port Numbers UDP Socket Application Service 0 reserved 2 Management Utility 7 Echo 9 Discard 11 Active Users systat 13 Daytime 35 Any private printer server 39 Resource Location Protocol 42 Host name server names server 43 Whois nickname 49 Login Host Protocol Login 53 Domain Name Server domain 69 Trivial Transfer Protocol TETP
83. Protos ipReasmFails IcmpOutTimeExcds ifOutOctets ipFragOKs IcmpOutParmProbs ifOutUcastPkts ipFragFails IcmpOutSrcQuenchs ifOutNUcastPkts ipFragCreates IcmpOutRedirects ifOutDiscards ipAdEntAddr IcmpOutEchos ifOutErrors ipAdEntl fl ndex IcmpOutEchoReps ifOutQLen ipAdEntNetMask IcmpOutTimestamps ifSpecific ipAdEntBcastAddr IcmpOutTimestampReps ipAdEntReasmMaxSize IcmpOutAddrMasks System MIB Interfaces MIB IP MIB ICMP MIB pNetToMedial fl ndex IcmpOutAddrMaskReps IpNetToMediaPhysAddres S IpNetToMediaNetAddress IpNetToMediaType IpRoutingDiscards MiiNePort E2 SNMP Agent with MIB II and RS 232 Like Groups UDP MIB TCP MIB SNMP MIB UdpInDatagrams tcpRtoAlgorithm snmpInPkts UdpNoPorts tcpRtoMin snmpOutPkts UdpInErrors tcpRtoMax snmpl nBadVersions UdpOutDatagrams tcpMaxConn snmpInBadCommunityNames UdpLocalAddress tcpActiveOpens snmpl nASNParseErrs UdpLocalPort tcpPassiveOpens snmpl nTooBigs tcpAttempFails snmpInNoSuchNames Address Translation MI B tcpEstabResets snmpl nBadValues Atl fl ndex tcpCurrEstab snmpInReadOnlys AtPhysAddress tcpInSegs snmpInGenErrs AtNetAddress tcpOutSegs snmpInTotalReqVars E 2 E NECI Library NECI Network Enabler Configuration Interface is a set of APIs that run on Windows systems 95 and above to search locate and configure MiiNePort Series modules over the netwo
84. SC module that attempts to query or change the MCSC behavior If a serial communication end wants to send a 0x10 DLE data byte it sends two DLEs one after the other The receiving end decodes these two DLEs into a single 0x10 byte Currently there are 4 kinds of control packets defined under MCSC Channel Switch Command 0x10 0x01 This command is used for an end to switch its active transmission channel The CHN field indicates the new channel number Note that the CHN index is zero based so you will need to use 0x00 for CHN to switch to channel 1 0x01 to switch to channel 2 and so on For safety reasons if one serial communication end receives a Channel Switch Command that switches to a channel it does not support it will simply discard it after the data has been transmitted Note that when you begin using MCSC both active communication channels are assumed to be channel 1 After serial communication has ended data is transferred without directing Channel Switch Command to the channel 1 application In the MiiNePort E2 SCM will always be enabled when MCSC is enabled A special channel indexed as OxFF in MCSC is dedicated for SCM For more information refer to the Serial Command Mode section in this chapter Example A gt 10 lol loz ea co B B gt 10 01 A gt B gt 10 loz loo 8 6 MiiNePort E2 NetEZ Technologies This example shows that
85. SI Command parameters Port index Reply parameters O RS232 or 1 RS485 2wire MiiNePort s Interface RSI1 04 System sets port1 s interface as RS232 IRSIOJ MiiNePort reports command executed successfully A 42 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Operation Mode Command code OM Command parameters numbers separated by a semicolon denotes port index and MCSC channel index For port itself channel index shall be 0 Reply parameters MiiNePort s operation mode index as following table 0 Disable 1 Real COM 2 RFC2217 3 TCP server 4 TCP client 5 UDP 6 EMODEM 7 MCSC This value is unavailable for MCSC channels ROM1 0J System requests for port 1 s Operation Mode for this MiiNePort IROMO4 4d MiiNePort reports Flow control is TCP client ROM1 2d When port 1 is set to MCSC system requests for operation mode for channel 2 of port 1 IROM02 d MiiNePort reports operation mode is RFC2217 Data Packing Length Command code OL Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters MiiNePort s data packing length as follows ROL1 0 System requests port 1 s data packing length for this MiiNePort ROLO256 MiiNePort reports data packing length as
86. Target host name or IP address Reply parameters A single minus symbol indicates the target host did not reply in 1000 milliseconds Otherwise one decimal number indicating the reply latency in milliseconds is returned CNPwww moxa come System requests to PING www moxa com I CNPO10 Target host replies in 10 milliseconds CNP192 168 1 1 System requests to PING 192 168 1 1 CNPO Target host did not reply in 1000 milliseconds A 53 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set DIO mode Command code PM Command parameters DIO port index For MiiNePort E2 the index is as following Index DIO port MiiNePort E2 PIN number 0 DIOO PIN15 1 DIO1 PIN16 2 DIO2 PIN17 3 DIO3 PIN18 Reply parameters 1 output or O input note that for MiiNePort E2 this configuration is available if specific PIN function is set to DIO CPM1 0J System sets DIO 1 s mode as input for this MiiNePort ICPMO4 MiiNePort reports command executed successfully DIO state Command code PS Command parameters DIO port index Reply parameters If the DIO port is in output mode a 0 denotes it is outputting a low signal or 1 for a high signal If the DIO port is in input mode a 0 denotes it receives a low signal and 1 for a high signal CPS0 14d System sets DIO 0 s state to high ICPSOJ MiiNePort reports c
87. UDP destination address is from 192 168 1 3 to 192 168 1 8 and port as 4001 UDP local listen port Command code UP Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters local listen port GUP1 0 System requests UDP local listen port for port 1 GUP4001 MiiNePort reports UDP local listen port as 4001 A 16 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set E modem alive check time Command code EA Command parameters Two numbers separated by a semicolon denotes port index and MCSC channel index For MCSC disabled port channel index shall be 0 Reply parameters TCP alive check time GEA1 0J System requests for TCP alive check time for port 1 IGEAO5 MiiNePort reports TCP alive check time is 5 minutes E modem local listen port Command code EP Command parameters Two numbers separated by a semicolon denotes port index and MCSC channel index For MCSC disabled port channel index shall be 0 Reply parameters local listen port GEP1 0J System requests UDP local listen port for port 1 IGEP040014 MiiNePort reports UDP local listen port is 4001 DIO initial mode Command code PM Command parameters DIO port index For the MiiNePort E2 the index is as follows
88. View settings Save and restart Quit Key in your selection MiiNePort E2 Initial I P Address Configuration 4 Select IP address by pressing 1 and then press Enter lt lt Main Menu gt Network settings lt B gt Device name lt i gt IP address 2 gt Netmask 3 gt Gateway lt 4 IP configuration lt 5 gt DNS server 1 lt 6 gt DNS server 2 lt v View settings lt m gt Back to main menu lt q Quit ey in your selection 1 lt a gt Configuration tools lt c Change password 1 gt Load factory default lt m gt Monitor lt p gt Ping Cy View settings lt s Save and restart lt q gt Quit Key in your selection lt lt Main Menu gt Network settings gt gt lt B gt Device name lt i gt IP address 2 gt Netmask lt 3 Gateway lt 4 IP configuration lt 5 gt DNS server 1 lt 6 gt DNS server 2 lt u View settings lt m gt Back to main menu Cq gt Quit ey in your selection 1 IP address 192 168 127 254 5 4 MiiNePort E2 Initial I P Address Configuration 6 Press any key to continue 7 Monitor Ping View settings lt s Save and restart lt q Quit Key in your selection lt Main Menu gt Network settings lt B gt Device name lt i gt IP address 2 gt Netmask 3 gt Gateway lt 4 IP configuration lt 5 gt DNS server 1 lt 6 gt DNS server 2 lt v View settings lt m gt Back to main menu lt q Quit ey in your sele
89. When the Delimiter is received the Delimiter is deleted i e stripped and the remaining data is transmitted Force transmit Setting Factory Default Necessity 0 to 65535 ms 0 ms Optional O Disable the force transmit timeout 1 to 65535 Forces the MiiNePort E2 s TCP IP protocol software to try to pack serial data received during the specified time into the same data frame This parameter defines the time interval during which the MiiNePort E2 fetches the serial data from its internal buffer If data is incoming through the serial port the MiiNePort E2 stores the data in the internal buffer The MiiNePort E2 transmits data stored in the buffer via TCP IP but only if the internal buffer is full or if the Force transmit time interval reaches the time specified under Force transmit timeout The optimal Force transmit timeout depends on your application but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits 1 stop bit and no parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is MiiNePort E2 Web Console Configuration 10 bits 1200 bits s 1000 ms s 8 3 ms Therefore you should set Force transmit timeout to be larger than 8 3 ms so in this case it must be greater than or equal to 10 ms If the user wants
90. a TCP IP but only if the internal buffer is full or if the Force transmit time interval reaches the time specified under Force transmit timeout The optimal Force transmit timeout depends on your application but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits 1 stop bit and no parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is 10 bits 1200 bits s 1000 ms s 8 3 ms Therefore you should set Force transmit timeout to a value larger than 8 3 ms so in this case it must be greater than or equal to 10 ms If the user wants to send a series of characters in the same packet the serial device attached to the MiiNePort E2 should send that series of characters during a time interval less than the Force transmit timeout for the MiiNePort E2 and the total length of data must be less than or equal to the MiiNePort E2 s internal buffer size The serial communication buffer size for the MiiNePort E2 is 1 KB per port MiiNePort E2 Web Console Configuration TCP Server Mode amp Main Menu A Overview EE Basic Settings Network Settings Serial Port Settings a Operation Modes EY Advanced Settings Accessible IP List E SNMP Agent 4 DIO Settings Operation Modes Mode TCP alive check time Inactivity time Max connection Ign
91. a ll E HEX 4D 4F 58 41 O1 04 54 45 53 54 02 02 19 41 03 06 00 90 E8 01 02 03 ASCII lem or xe a ope pape ego q C 2 D DIO Commands In this appendix we provide information on sending commands to the module s DIO channels over an Ethernet network Digital O commands and responses are accessed using a specific TCP port default 5001 on the module Each command is initiated by the host and is followed by a response from the module A utility on the CD ROM can be used to test the DIO access commands The following topics are covered in this appendix O Overview O C Code Example O Read Single DIO gt Command gt Response gt C Code Example O Write Single DIO gt Command gt Response gt C Code Example O Read Multiple DIOs gt Command gt Response gt C Code Example O Write Multiple DI Os gt Command gt Response gt C Code Example MiiNePort E2 DIO Commands Overview Each DIO command and response consists of a 4 byte header and up to 255 bytes of data The first byte of the header indicates the command The second byte indicates the version which is 2 for current firmware versions The third byte is a code that is used by the module to report errors The fourth byte is the number of bytes that follows the header and will depend on the command or response In the event of an error
92. able and http port as 80 Telnet console Command code BT Command parameters N A Reply parameters 1 and telnet console TCP port separated by a semicolon if telnet console is enabled or a 0 if it is disabled GBT System requests telnet console setting for this MiiNePort IGBT01 23 MiiNePort reports telnet console as Enable and telnet port as 23 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Auto configuration Command code BA Command parameters N A Reply parameters 1 if Auto configuration is enabled O otherwise 2GBA System requests Auto configuration setting for this MiiNePort IGBAO01 MiiNePort reports Auto configuration as Enable NECI utility accessibility Command code BU Command parameters N A Reply parameters 1 if NECI is enabled O otherwise GBU System requests NECI setting for this MiiNePort IGBU0O1 MiiNePort reports NECI as Enable IP configuration Command code NC Command parameters N A Reply parameters MiiNePort s IP configuration index as follows 0 Static 1 DHCP 2 DHCP BOOTP 3 BOOTP 4 AUTOIP 2GNC System requests IP configuration for this MiiNePort GNCOO MiiNePort reports IP configuration as Static IP address Command code NI Command parameters N A Reply parameters MiiNePort s IP address
93. arameters N A SMS1 System sets SNMP agent as Enable ISMSO MiiNePort reports command executed successfully A 22 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Community String Command code MU Command parameters MiiNePort s SNMP Community string Reply parameters N A SMUpublice System sets SNMP community string as public ISMUO MiiNePort reports command executed successfully Contact Name Command code MN Command parameters MiiNePort s SNMP contact name Reply parameters N A SMNcontact System sets SNMP contact name as contatct ISMNO MiiNePort reports command executed successfully Location Command code ML Command parameters MiiNePort s SNMP location Reply parameters N A SMLlocatione System sets SNMP contact name as location ISMLO MiiNePort reports command executed successfully Enable Disable Accessible IP List Command code AS Command parameters 1 Enable or 0 Disable MiiNePort s accessible IP list Reply parameters N A SAS1 System sets accessible IP list as Enable ISASO MiiNePort reports command executed successfully A 23 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Accessible IP List Command code Al Command parameters format is index mode IP Netmask where index ranges from 1 to 16 mo
94. are costs to you In short MCSC allows multiple application channels to share a single physical serial port at the same time Communication Model In traditional serial communication models communication is accomplished by connecting two devices over a single serial channel At the embedded device server end Operating Mode OP Mode enables the other end of the serial channel to transmit or receive data from the network However only one application TCP Server transportation TCP Client transportation or UDP transportation is supported at a time The communication model is depicted in the following figure Refer to Chapter 3 Choosing the Proper Operation Mode for an introduction to the operation modes supported by the MiiNePort E2 8 4 MiiNePort E2 NetEZ Technologies Although there are UARTs and even an OS and driver stacks between the TCP Server Application and Controller Application the applications are considered to be connected by a logical bi directional channel indicated in red in the following figure TCP Communication TCP Server Controller Application Application Embedded Device Server wus3s s BuljjouquoD Serial Communication When using MCSC each serial communication end is attached with an MCSC command encoding and decoding module in this case module refers to a software programming module This module is used primarily for UART applications It compresses the data transmitted by the application to
95. ation Export 2 Load Factory Default Change Password Save and Restart Auto Configuration Auto configuration AutoCFG OEnable O Disable For more information on AutoCFG refer to Chapter 8 NetEZ Technologies Configuration I mport You can select the proper cfg txt file and then import it to instantly to copy the configuration to the current module Also you can choose whether to import IP configurations at the same time E Main Menu Overview Basic Settings EA Advanced Settings EXA Maintenance Console Settings EX Configuration Tool 2 Auto Configuration 2 Configuration Import 1 Configuration Export 2 Load Factory Default Change Password Save and Restart Configuration Import Configuration Import Select configuration file Import all configurations including IP configurations IP configuration Configuration Export You can download the current configuration file by clicking on Configuration Export The configuration file MiiNePortE2 txt MiiNePortE2 H txt can be used later in Configuration Import for effortless configuration replication or AutoCFG for mass configuration deployment during your device s mass production stage 3 Main Menu 5 Configuration Export Overview EA Basic Settings Configuration Export EA Advanced Settings EX Mai SY Maintenance 2 Console Settings EX Configuration Tool A Auto Configuration 4 Configuration Import Configuration Export
96. ber the IP address reports will be sent to the specified address and port number Auto report period Setting Factory Default Necessity Time interval in seconds 10 Optional The Auto report period field specifies how often the module will report its IP address An auto report period of 10 seconds means that an IP address report will be sent every 10 seconds ATTENTION The module will send IP address reports only when assigned an IP address from a DHCP or BOOTP server If a connection to a DHCP or BOOTP server is not available no IP address report will be sent Maintenance Console Settings You can enable or disable the Web Telnet and Utility console functions on this page You can also set up the Web server port number and Telnet server port number here amp Main Menu a Console Settings Overview EU Basic Settings Console EX Advanced Settings Web console Enable O Disable Accessible IP List Web server port 80 SNMP Agent Telnet console Enable O Disable A DIO Settings Telnet server port 23 Y Serial Command Mo NECI utility accessibility Enable ODisable A Miscellaneous EA Maintenance A Console Settings Firmware Upgrade El A Configuration Tools Change Password 4 Load Factory Defaul gt a Firmware Upgrade SJ Main Menu overview E Basic Settings E Advanced Settings 2 Maintenance E Console Settings E Firmware Upgrade E Configuration
97. channel status has been changed to low 1 channel status has been changed to high 7 Data 0 1 2nd requested DIO channel 0 channel has been changed to input mode 1 channel has been changed to output mode 8 Data 0 1 2nd requested DIO channel 0 channel status has been changed to low 1 channel status has been changed to high 9 Data 0 1 3rd requested DIO channel optional 0 channel has been changed to input mode 1 channel has been changed to output mode 10 Data 0 1 3rd requested DIO channel optional 0 channel status has been changed to low 1 channel status has been changed to high 11 Data 0 1 4th requested DIO channel optional 0 channel has been changed to input mode 1 channel has been changed to output mode 12 Data 0 1 4th requested DIO channel optional 0 channel status has been changed to low 1 channel status has been changed to high For example the 8 byte response 6 2 0 4 0 0 1 1 indicates that DIO 0 has been changed to input mode and low status and DIO 1 has been changed to output mode and high status C Code Example void WriteMultipleDIO int start int end int mode int status DIOPacketStruct packet packet header command 6 Write Multiple DIO Command Codes packet header version 2 DIO protocol version packet header length end start 1 2 2 data length packet data 0 start start DIO number packet data 1 end end
98. colon denotes port index and MCSC channel index For MCSC disabled port channel index shall be 0 Reply parameters TCP port GTO1 0J System requests for TCP command port for port 1 GTOO966 MiiNePort reports TCP command port is 966 TCP server Allow Driver Control Command code TD Command parameters Two numbers separated by a semicolon denotes port index and MCSC channel index For MCSC disabled port channel index shall be 0 Reply parameters 1 Enable or O Disable GTD1 0J System requests for allow driver control policy for portl IGTDO1J MiiNePort reports allow driver control is Enable TCP Client Connection Control Command code TC Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters TCP client connection control index as shown in the following table 0 Any character 1 Manual connection 2 Start up 3 With DSR on GTC1 0 System requests TCP client connection control for port I IGTCO1 MiiNePort for TCP client connection control as Any character A 14 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set TCP destination address Command code TI Command parameters Three numbers separated by a semicolon denote port index MCSC channel index and destinat
99. covered in this chapter o o o o EZPower SCM Serial Command Mode AutoCFG Auto Configuration MCSC Multiple Channel Serial Communication gt Command Packets gt SCM Serial Command Mode under MCSC EZPage gt How to Clean up EZPage in MiiNePort MiiNePort E2 NetEZ Technologies EZPower MiiNePort E2 s EZPower function provides a versatile system power input voltage Use EZPower for 3 3 or 5 VDC system power input SCM Serial Command Mode MiiNePort E2 s SCM Serial a Command Mode allows the module s parameters to be retrieved or configured through the serial port rather than over the network This is done through the use of specially parsed commands sent to the module through the serial port SCM is often used when your device has already been used in actual applications and you n eed to change the MiiNePort E2 s configuration such as changing the device s IP address by using your device s key pad Refer to Chapter 7 Web Console Configuration for the most appropriate way to use SCM for your application Refer to Appendix A Introduction to SCM Serial Command Mode Command Set for detailed instructions on using SCM commands 8 2 MiiNePort E2 NetEZ Technologies AutoCFG Auto Configuration The MiiNePort E2 s AutoCFG function is designed to allow users to realize true mass production With AutoCFG you no longer need to configure network modules one by one during the de
100. ction 1 IP address 192 168 127 254 Set IP address success ress any key to continue lt 5 gt server 1 lt 6 gt DNS server 2 lt u View settings lt m gt Back to main menu lt q Quit Key in your selection 1 IP address 192 168 127 254 Set IP address success ress any key to continue lt Main Menu gt Network settings lt B gt Device name lt i gt IP address 2 gt Netmask 3 gt Gateway lt 4 IP configuration lt 5 DNS server 1 lt 6 gt DNS server 2 lt u View settings lt m gt Back to main menu lt q Quit ey in your selection m gt gt Press M and then Enter to return to the main menu MiiNePort E2 Initial I P Address Configuration 8 Press S and then Enter to Save Restart the system Model name MiiNePort E2 Serial No 279 Device name MiiNePort Firmware version Ethernet MAC address 1 0 Build 16066317 lt Main Menu gt gt lt B gt 4D 2 gt lt 3 lt 4 gt lt 5 gt lt 6 gt lt 7 lt 8 gt lt a gt cc lt 1 gt lt m gt lt p gt lt u gt Cs lt q gt Network settings Serial settings Operation mode settings Accessible IP list SNMP agent DIO settings Serial command mode settings Miscellaneous Console settings Configuration tools Change password Load factory default Monitor Ping View settings Save and restart Quit Key in your selection s 9 Press Y and then Enter to save the new IP address and
101. d Settings PHY Speed Auto m Accessible IP List Status 100Mbps Full SNMP Agent Pin and 10 Settings A Serial Command Mode Miscellaneous Gratuitous ARP Gratuitous ARP JEnabled Send period 300 10 1000 sec Auto IP Report EA Maintenance Auto report to Port 4002 Save and Restart Auto report period 10 0 99sec IP Address Report Structure The first 4 bytes of the module s IP address report are the characters MOXA The rest of the report is composed of 9 items with each item preceded by a 2 byte header indicating the item ID and item length Header Header Item Item 1D Item Length none none Moxa text string 1 varies server name text string 2 2 hardware ID little endian see table below 3 6 MAC address 00 90 E8 01 02 03 would be sent in sequence as 0x00 0x90 OxE8 0x01 0x02 0x03 serial number little endian DWORD IP address Netmask default gateway firmware version little endian DWORD Version 4 3 1 0x04030100 AP ID little endian DWORD see table below ojoon Ss HLH HHL HLA MiiNePort E2 Auto IP Report Protocol Example The following example shows the first 22 bytes of a typical IP address report S hardware report header a server name a a MAC address A 8 a gt a 1D a 5 Moxa i ee TEST phd 0x4119 00 90 E8 01 02 03 E E E al g 0 o o o 0 0 Es 2 E
102. d to the MiiNePort You can combine EZPage and MiiNePort s firmware as one file and upload it via MiiNePort s web console Log in to the MiiNePort s web console and upgrade the firmware by using combined firmware How to Clean up EZPage in MiiNePort Execute the EZPageTool command with the cleanfs parameter to clean up EZPage of specified MiiNePort in command prompt mode Usage cleanfs device IP Example cleanfs 192 168 35 101 You will see the following message if the clean up process executed successfully MOXA EZPageTool Version 1 0 clean file success 8 10 A Introduction to SCM Serial Command Mode Command Set The following topics are covered in this appendix Command Reply Format Command Code for Getting the Configuration Command Code for Setting the Configuration Command Code for Retrieving Running Configuration Command Code for Viewing the Status 00900000 Control Command Code MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Command Reply Format Single Line Command Format Head Op Cmd Parameters Tail 1 byte 1 byte 2 bytes O to n bytes 1 or 2 bytes Single Line Reply Format Head Op Cmd Parameters Tail 1 byte 1 byte 2 bytes O to n bytes 1 or 2 bytes Head and Tail Head Tail 1 byte 1 or 2 bytes CR Command LF CR LF Reply LF Operation Code Operation Code Meaning G Get conf
103. de is 1 if activated and 0 if not activated Reply parameters N A SAI1 1 192 168 1 2 255 255 255 0 System sets accessible IP 1 as active IP address as 192 168 1 2 and netmask as 255 255 255 0 ISAIO MiiNePort reports command executed successfully Auto IP Report Command code NR Command parameters Auto IP report destination and report period Reply parameters N A SNR192 168 1 123 4000 50 System sets auto report IP as 192 168 1 123 UDP port as 4000 and report period as 50 sec ISNRO MiiNePort reports command executed successfully Port alias Command code SA Command parameters Port index and port alias separated by a semicolon Reply parameters N A SSA1 port 1 System sets port 1 s alias name as port 1 ISSA0C MiiNePort reports command executed successfully Baud rate Command code SB Command parameters Port index and baudrate separated by a semicolon Reply parameters N A SSB1 115200 System sets port 1 s baudrate as 115200 ISSBO MiiNePort reports command executed successfully A 24 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Data bits Command code SD Command parameters Port index and data bits separated by a semicolon Reply parameters N A SSD1 8 System sets port 1 s data bits as 8 ISSDO0 Mii
104. dules will import the configuration save the configuration Once the MiiNePort E2 finishes the self configuration process the Fault In Use LED on the RJ 45 connector will blink in Green When you see the LED blinking the AutoCFG task is completed and you can restart your device or power it off Step 7 When you need to change the configuration just complete the revised configuration export the new MiiNePortE2 txt save the file to the TFTP server choosing to replace the original MiiNePortE2 txt under the root directory Your MiiNePort E2 modules will then be able to retrieve the correctly revised configuration ATTENTI ON Check the following if AutoCFG is not working properly on your device 1 Make sure the AutoCFG function is enabled the function is enabled by default 2 Check to see if the TFTP Server is working properly 3 Make sure the specific configuration filename is MiiNePortE2 txt 8 3 MiiNePort E2 NetEZ Technologies ATTENTION There is no theoretical limit to the number of MiiNePort E2 modules that can be connected at the same time to one subnet for conducting an AutoCFG task ATTENTION Even if you do not want to use the auto configuration function the module will still go through the process of searching for the MiiNePort E2 txt file on the network every time it starts up if you do not disable the AutoCFG function on your MiiNePort E2 The MiiNePort E2 will resume normal operation if it cannot find which netw
105. e Real COM driver comes with NPort Windows Driver Manager included on the CD ROM in the MiiNePort E2 package ATTENTION Real COM mode allows several hosts to have simultaneous access to the module The driver controls host access to attached serial devices by checking the host s IP address against the Accessible IP list Use the Accessible IP table to restrict access to the module when a public IP address is required for your application Ethernet Modem Mode Ethernet Modem Mode is designed for use with legacy operating systems such as MS DOS that do not support TCP IP Ethernet By connecting the MiiNePort E2 evaluation board s serial ports to an MS DOS computer s serial port it is possible to use legacy software originally designed to transmit data via modem but now transmit the data over the Ethernet MCSC Mode MCSC Multiple Channel Serial Communication was developed for multiple serial to Ethernet applications that use only one serial port For example if you need your device to act as a TCP Server and TCP Client at the same time as illustrated below you can use MCSC Host B TCP Client Host A TCP Server TCPAP Ethernet Device in Device in O Channel 1 Channel 2 Devi TCP Client TCP Client TCP Server evice acts as TCP Client a Selle tated requests a connection to Host A then proceed with data transmission MiiNePort E2 n Device acts as TCP Serial TTL Server waits for a Divided into 2
106. e for Viewing the Status Ethernet Speed and Duplex Command code NS Command parameters N A Reply parameters The speed and duplex status of the Ethernet Possible values are O Unlink 10H 10Mbps Half Duplex 10F 10Mbps Full Duplex LOOH 100Mbps Half Duplex 100F 100Mbps Full Duplex 2VNS lt System requests current Ethernet status IVNSO100F MiiNePort reports the Ethernet is current in 100Mbps Full Duplex mode A 52 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set DIO mode Command code PM Command parameters DIO port index and 1O mode 0 for input and 1 for output separated by semicolon For MiiNePort E2 the index is as following Index DIO port MiiNePort E2 PIN number 0 DIOO PIN 15 1 DIO 1 PIN 16 2 DIO 2 PIN 17 3 DIO 3 PIN 18 Note that this function works only if related PIN function is set to DIO Reply parameters N A 2VPM2 System requests for DIO running mode of DIO port 2 IVPMO1 MiiNePort reports DIO port is in output DI O state Command code PS Command parameters DIO port index and output state 0 for low and 1 for high Note that this function works only if DIO mode is set to output Reply parameters N A 2VPS2 J System requests for DIO state of DIO port 2 IVPSO1J MiiNePort reports DIO port is in high state Control Command Code PING Command code NP Command parameters
107. ecute mxdelsvr to delete a server The syntax of mxdelsvr is mxdelsvr IP Address Example cd usr lib npreal2 driver mxdelsvr 192 168 3 4 The following actions are performed when executing mxdelsvr 1 Modifies npreal2d cf 2 Removes the relevant tty ports in directory dev 3 Restart the driver If the IP address is not provided in the command line the program will list the installed servers and total ports on the screen You will need to choose a server from the list for deletion Removing Linux Driver Files A utility is included that will remove all driver files mapped tty ports and unload the driver To do this you only need to enter the directory usr lib npreal2 driver and then execute mxuninst to uninstall the driver This program will perform the following actions Unload the driver Delete all files and directories in usr lib npreal2 Delete directory usr lib npreal2 Modify the system initializing script file AN ia 6 9 MiiNePort E2 Utility Console and Driver I nstallation The UNIX Fixed TTY Driver Installing the UNIX Driver 1 Login to UNIX and create a directory for the Moxa TTY To create a directory named usr etc execute the command mkdir p usr etc 2 Copy moxattyd tar to the directory you created If you created the usr etc directory above you would execute the following commands cp moxattyd tar usr etc cd usr etc 3 Extract the source
108. eeeeeceeeeeeaeaeeaeaeeaeaeeaeaseasageasaeeaeaeeaeaeeaeageasaeeaeageaeageanaes C 1 IP Address Report Structure 0 EEE etn e naar rra E REEE nnn C 1 Exampl enm chateaus tee as uit acetoacetate ral oi ran ere pe hm atl poy need E ESENS C 2 DIO COMMANAi 2 ceseceeeeeeeeeeeeeeeeeeeeeeeeeneueueueuauauauauauauauauauauaeeeeeeeeeecueneueueueeeeeeaueuauauauauauauauaueeeceeasueueueuens D 1 ONY lt 1 AIGA ona oa aa D 2 C C de EXAM Pleat entte ete A o litis D 2 REAPS ING DD SSA A Sete aid ula uta aie ate AS eta viva aa ua ee D 2 Command ntie ieee e eiee eiee e eee eat e e ee eee ieie ae a ee aen alee ta eta D 2 RESPONSE D 3 ECOde E E iia c nso D 3 Write SINOle DIO satis oaia a aE E AE E hi eatin a hada adda a alana han ahead olan de D 3 COMMANG NN D 3 RESPONS riscos D 4 ECode EXAMPLE A D 4 Read Multiple DM A vireteveyoescwteda sale ecred eve yaresa yee veretegeyrewewtede a a a a R E EEA D 4 COMMANA atraido heh a ai hehehe Ae atte Aten AAAA D 4 RESO MISC tdci cesar stata a aE O attra Ea shale AS ARA AAA AR a alate Ghats datada D 5 ExCode Example ee none tacto D 5 Write Multiple Disco A A AAA IA AA D 6 Command Aoise A jel le E ce nent cate ail ean aula nnn nate unin ae eae ate nite lee D 6 RESPONSE encarnan aia AAE AA AE AAE EE AGA GEA D 6 C Code EXA li ss D 7 SNMP Agent with MIB II and RS 232 Like GroupS ocmonocnonncnonacannncnnnncanancnnnncnnrncnnrnrnnrncnnraranrncanrncanans E 1 NECI Library cccononocncnocncnonncnncnnnnrnnnnrnn nr nena
109. elimiter 2 Strip Delimiter The Delimiter process field determines how the data is handled when a delimiter is received Delimiter 1 must be enabled for this field to have effect If Delimiters 1 and 2 are both enabled both characters must be received for the delimiter process to take place Do Nothing Data in the buffer will be transmitted when the delimiter is received Delimiter 1 Data in the buffer will be transmitted after 1 additional byte is received following the delimiter Delimiter 2 Data in the buffer will be transmitted after 2 additional bytes are received following the delimiter Strip Delimiter When the Delimiter is received the Delimiter is deleted i e stripped and the remaining data is transmitted Force transmit Setting Factory Default Necessity 0 to 65535 ms 0 ms Optional O The force transmit timeout is disabled 1 to 65535 If the module does not receive the next byte of data within the time specified it will pack the data in its buffer into the same data frame for network transmission 7 9 MiiNePort E2 Web Console Configuration The Force transmit field is typically used in conjunction with the Delimiter fields to specify how data in the module s buffer is packed for network transmission When delimiters are used the module accumulates data in its buffer as it waits to receive a delimiter If there is a break in communication data will be held in the buffer as the
110. emicolon For an MCSC disabled port the channel index is 0 Allow driver control is 1 Enable or 0 Disable Reply parameters N A SRD1 0 0 System sets allow driver control policy as Disable for port 1 ISRDO MiiNePort reports command executed successfully RFC2217 TCP alive check time Command code FA Command parameters Port index MCSC channel index and TCP alive check time Every parameter is separated by semicolon For MCSC disabled port channel index shall be 0 Reply parameters N A 2SFA1 0 54 System sets port 1 s TCP alive check time as 5 for port 1 ISFAOJ MiiNePort reports command executed successfully RFC2217 local listen port Command code FP Command parameters Port index MCSC channel index and TCP local port Every parameter is separated by semicolon For MCSC disabled port channel index shall be 0 Reply parameters N A SFP1 0 4100 4 System sets TCP port as 4100 for port 1 ISFPOJ MiiNePort reports command executed successfully A 29 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set TCP alive check time Command code TA Command parameters Port index MCSC channel index and TCP alive check time Parameters are separated by a semicolon Reply parameters N A STA1 0 5 System sets port 1 s TCP alive check time to 5 minutes ISTAO9 MiiNePort reports comma
111. emicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters 1 Enable or O Disable RRD1 0 System requests allow driver control policy for port1 IRRDO1 MiiNePort reports allow driver control as Enable RFC2217 TCP alive check time Command code FA Command parameters Two numbers separated by a semicolon denotes port index and MCSC channel index For MCSC disabled port channel index shall be 0 Reply parameters 1 Enable or O Disable RFA1 04 System requests for alive check time for portl IRFAO1J MiiNePort reports alive check time is 1 RFC2217 local listen port Command code FP Command parameters Two numbers separated by a semicolon denotes port index and MCSC channel index For MCSC disabled port channel index shall be 0 Reply parameters local listen port RFP1 0J System requests for RFC2217 local listen port for port 1 IRFP012344 MiiNePort reports RFC2217 local listen port is 1234 A 45 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set TCP alive check time Command code TA Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters TCP alive check time RTA1 0 System requests TCP alive check time for
112. er method for this MiiNePort IGCTO1 MiiNePort reports serial command mode is triggered by DIO1 Serial command mode trigger characters Command code CC Command parameters N A Reply parameters serial command mode trigger characters in hex separated by a semicolon Note that this configuration is valid only if the serial command mode trigger method is set to Activated by characters GCCH System requests serial command mode trigger characters for this MiiNePort 1GCC058 58 58 MiiNePort reports serial command mode triggered by XXX 0x585858 A 18 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Serial command mode triggered only at boot up Command code CB Command parameters N A Reply parameters 0 if serial command mode can be triggered at any time or 1 if it can only be triggered at boot up Note that this configuration is valid only if the serial command mode trigger method is set to Activated by characters 2GCB System requests serial command mode for this MiiNePort IGCBO1 MiiNePort reports serial command mode can only be triggered by characters at boot up Gratuitous ARP Command code VA Command parameters N A Reply parameters 1 and send period if gratuitous ARP is enabled otherwise reply 0 2GVA System requests gratuitous ARP status for alert mail server IGVA1 300 MiiNePort reports gratuitou
113. ernet However to use the delimiter function you must at least enable Delimiter 1 If Delimiter 1 is left blank and Delimiter 2 is enabled the delimiter function will not work properly Delimiter process Setting Factory Default Necessity Do Nothing Do Nothing Optional Delimiter 1 Delimiter 2 Strip Delimiter Do Nothing The data will be transmitted when the Delimiter is received Delimiter 1 or Delimiter 2 The data will be transmitted when an additional byte for Delimiter 1 or an additional 2 bytes for Delimiter 2 of data is received after receiving the Delimiter Strip Delimiter When the Delimiter is received the Delimiter is deleted i e stripped and the remaining data is transmitted Force transmit Setting Factory Default Necessity 0 to 65535 ms 0 ms Optional 0 Disable the force transmit timeout 1 to 65535 Forces the MiiNePort E2 s TCP IP protocol software to try to pack serial data received during the specified time into the same data frame This parameter defines the time interval during which the MiiNePort E2 fetches the serial data from its internal buffer If data is incoming through the serial port the MiiNePort E2 stores the data in the internal buffer The MiiNePort E2 transmits data stored in the buffer via TCP IP but only if the internal buffer is full or if the Force transmit time interval reaches the time specified under Force trans
114. etermine the maximum possible current in each power wire and common wire Observe all electrical codes dictating the maximum current allowable for each wire size If the current goes above the maximum ratings the wiring could overheat causing serious damage to your equipment ATTENTION Take care when handling the evaluation boards When plugged in the evaluation boards internal components generate heat and consequently the board may feel hot to the touch You should also pay attention to the following e Donotrun signal or communication wiring and power wiring in the same wire conduit To avoid interference wires with different signal characteristics should be routed separately Separate paths should be used to route wiring for power and devices You can use the type of signal transmitted through a wire to determine which wires should be kept separate The rule of thumb is that wires sharing similar electrical characteristics may be bundled together e Keep input wiring and output wiring separate e f power wiring and device wiring paths must cross paths make sure the wires are perpendicular at the intersection point e All wiring should be clearly labeled Installing the MiiNePort E2 onto the MiiNePort E2 ST Before using the MiiNePort E2 ST evaluation board with the module be sure to disconnect the power supply network and serial device In the top center of the evaluation board there is a MiiNePort E2 profile that indicate
115. g the utility web or Telnet console to verify that the update was successful Telnet Console Depending on how your computer and network are configured you may find it convenient to use network access to set up your module s IP address This can be done using Telnet which requires that the module has a network connection and an IP address 1 From the Windows desktop click Start and then select Run 2 Telnet to the module s current IP address If this is the first time configuring the module you will telnet to the default IP address by typing telnet 192 168 127 254 in the Open text box Click OK to proceed Type the name of a program folder document or Internet resource and Windows will open it for you telnet 192 168 127 254 Cancel Browse 3 Select Network settings by pressing O and then press Enter AJ Model name MiiNePort E2 Serial No 779 Device name MiiNePort Firmware version 1 0 Build 16666317 Ethernet MAC address 66 90 E8 60 07 79 lt lt Main Menu gt gt lt a gt lt i gt 2 gt 3 gt lt 4 gt lt 5 gt lt 6 gt 9 lt 8 gt lt a gt Cc gt lt 1 gt lt m gt lt p gt lt u gt Cs Cq gt Network settings Serial settings Operation mode settings Accessible IP list SNMP agent DIO settings Serial command mode settings Miscellaneous Console settings Configuration tools Change password Load factory default Monitor Ping
116. gs Local TCP port 4001 A Operation Modes 0 Advanced Settings Data Packing Packet length 0 0 1024 EJ Maintenance Delimiter 1 00 Hex U Enable Save and Restart Delimiter 2 DO Hex Enable Delimiter process Do nothing Force transmit 0 0 65535 ms TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Optional O min TCP connection is not closed due to an idle TCP connection 1 to 99 min The MiiNePort E2 automatically closes the TCP connection if there is no TCP activity for the given time After the connection is closed the MiiNePort E2 starts listening for another host s TCP connection Local TCP port Setting Factory Default Necessity 1 to 65535 4001 Required The Local TCP port is the TCP port that the MiiNePort E2 uses to listen to connections and that other devices must use to contact the MiiNePort E2 To avoid conflicts with well known TCP ports the default is set to 4001 Packing length Setting Factory Default Necessity O to 1024 0 Optional Default 0 The Delimiter Process will be followed regardless of the length of the data packet If the data length in bytes matches the configured value the data will be forced out The data length can be configured for 0 to 1024 bytes Set to 0 if you do not need to limit the length 7 10 MiiNePort E2 Web Console Configuration Delimiter 1 Setting Fac
117. hall be 0 Reply parameters TCP client connection control index as following table Start up None Any character None Any character Inactivity time DSR On DSR OFF DSR On None DCD On DCF OFF DCD On None Dj O B uWU N R O RTC1 0d System requests for TCP client connection control for port 1 IRTCO1J MiiNePort reports TCP client connection control is Any character None TCP destination address Command code TI Command parameters Three numbers separated by a semicolon denotes port index MCSC channel index and destination address index For MCSC disabled port channel index shall be 0 The destination address index is as following Destination address Alternated address 1 Alternated address 2 W IN R O Alternated address 3 Reply parameters TCP destination address and port RTI1 0 1d System requests for destination address 1 for port 1 IRTI0192 168 1 2 40014d MiiNePort reports destination address is 192 168 1 2 and port is 4001 TCP client local port Command code TL Command parameters Two numbers separated by a semicolon denotes port index and MCSC channel index For MCSC disabled port channel index shall be 0 Reply parameters TCP port RTL1 0d System requests for TCP client local port setting for port 1 IRTLO5002 MiiNePort reports TCP client local port is 4001
118. hannel and vice versa 3 As with traditional serial applications MCSC modules are logically connected to a bi directional channel To use the serial bandwidth more effectively MCSC modules separate it into two uni directional channels Each MCSC module maintains its transmission application channel and reception application channel That is the transmission channel of one end is the reception channel of another 4 Although logically all upper application channels share one physical serial port only one channel can be connected to the physical serial port to prevent confusion That is the application channel connected to the transmission channel is called the active transmission channel which transmits data to the serial channel The application channel connected to the reception channel is called the active reception channel which receives data from the serial channel 5 An MCSC module decides the active transmission channel In other words the active reception channel is decided by the other MCSC module lying at the other end of the serial communication channel 6 To avoid data loss we recommend that MCSC is applied with flow control over serial communication Command Packets An MCSC control packet begins with an ASCII DLE Data Link Escape 0x10 character An end of serial communication normally an MCSC module treats the DLE it receives as a special delimiter that indicates the other end of serial communication normally another MC
119. haracter None Startup None Required Any Character Inactivity Time DSR ON DSR OFF DSR ON None DCD ON DCD OFF DCD ON None MiiNePort E2 Web Console Configuration The meaning of each of the above settings is given in the table below In general both the Connect condition and Disconnect condition are given Connect Disconnect Description Startup None default A TCP connection will be established on startup and will remain active indefinitely Any Character None ATCP connection will be established when any character is received from the serial interface and will remain active indefinitely Any Character Inactivity Time A TCP connection will be established when any character is received from the serial interface and will be disconnected when the Inactivity time out is reached DSR On DSR Off A TCP connection will be established when a DSR On signal is received and will be disconnected when a DSR Off signal is received DSR On None A TCP connection will be established when a DSR On signal is received and will remain active indefinitely DCD On DCD Off A TCP connection will be established when a DCD On signal is received and will be disconnected when a DCD Off signal is received DCD On None A TCP connection will be established when a DCD On signal is received and will remain active indefinitely UDP Mode
120. hat stopped responding and continue data transmission to the other hosts NOTE Ignore Jammed IP is only valid when the Max connection is greater than 1 Allow driver control Setting Factory Default Necessity Enable Disable Enable Required when Max connection is greater than 1 NOTE Allow drive control is only valid when Max connection is greater than 1 This option determines how the port will proceed if driver control commands are received from multiple hosts that are connected to the port If Disable is selected driver control commands will be ignored If Enable is selected control commands will be accepted with the most recent command received taking precedence 7 8 MiiNePort E2 Web Console Configuration Packet length Setting Factory Default Necessity 0 to 1024 bytes O byte Required The Packet length setting refers to the maximum amount of data that is allowed to accumulate in the serial port buffer before sending At the default of O for packet length no maximum amount is specified and data in the buffer will be sent as specified by the delimiter settings or when the buffer is full When a packet length between 1 and 1024 bytes is specified data in the buffer will be sent as soon as it reaches the specified length Delimiter 1 Setting Factory Default Necessity 00 to FF 0 for None Optional Delimiter 2 Setting Factory Default Necessity 00 to F
121. he current TCP connection is kept active until a connection close request is received Although Inactivity time is disabled the MiiNePort E2 will check the connection status between the MiiNePort E2 and remote host by sending keep alive packets periodically If the remote host does not respond to the packet the MiiNePort E2 assumes that the connection was closed down unintentionally The MiiNePort E2 will then force the existing TCP connection to close ATTENTION The Inactivity time should at least be set larger than that of Force transmit timeout To prevent the unintended loss of data due to the session being disconnected it is highly recommended that this value is set large enough so that the intended data transfer is completed Max connection Setting Factory Default 1 2 3 4 1 Necessity Required Max connection is usually used when the user needs to receive data from different hosts simultaneously The factory default only allows 1 connection at a time 7 12 MiiNePort E2 Web Console Configuration Max connection 1 The MiiNePort E2 only allows 1 host to open the TCP connection to the specific serial port Max connection 2 to 4 Allows 2 to 4 host s TCP connection request to open this MiiNePort E2 s serial port at the same time When multiple hosts establish a TCP connection to the specific serial port at the same time the MiiNePort E2 will duplicate the serial data and transmit to all of the
122. iguration from MiiNePort s RAM S Set configuration to MiiNePort s RAM R Retrieve running configuration V View status C Control Status Code Status Code Meaning E Enter Serial Command Mode 0 Command was executed successfully 1 Unrecognized format 2 Operation is not valid 3 Command is not valid 4 Parameter is incorrect 5 Parameter is too long Restriction The total amount of parameters within a single command must not exceed 1024 characters MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Command Code for Getting the Configuration Device Name Command code BN Command parameters N A Reply parameters MiiNePort s name GBNe System requests configured device name for this MiiNePort GBNOMiiNePort_E2_9527 MiiNePort reports device name as MiiNePort_E2_9527 Console Password Command code BP Command parameters N A Reply parameters MiiNePort s console password 2GBP System requests console password for this MiiNePort IGBP01234 MiiNePort reports console password as 1234 Web console Command code BH Command parameters N A Reply parameters 1 and web console TCP port separated by a semicolon if web console is enabled or a 0 if it is disabled 2GBH System requests http console setting for this MiiNePort GBHO1 80 MiiNePort reports http console as En
123. ils about SCM commands refer to Chapter 8 NetEZ Technologies amp Main Menu 5 Serial Command Mode Overview E Basic Settings Serial Command Mode E3 Advanced Settings Way to enter serial command mode Activate by characters Y Accessible IP List SW trigger character 58 ss 58 0x00 Oxff SNMP Agent DIO Settings Only at boot up Y Submit Miscellaneous 9 Maintenance Save and Restart Way to enter serial command mode Setting Factory Default Necessity Disable H W control Activate by characters Only at boot up Required pin DIO1 Activate by characters Activate by break signal There are three ways to access SCM H W control pin DIO 1 Access SCM by pulling JP3 Pin2 the DIO1 to low Activate by characters Access SCM by sending the MiiNePort E2 s configurable three characters from your device s main system Check Only at boot up if you want to make this effective only when booting up the MiiNePort E2 ee Serial Command Mode E Basic Settings Serial Command Mode EXSY Advanced Settings Way to enter serial command mode Accessible IP List SW trigger character se 58 58 0x00 Oxff SNMP Agent DIO Settings Serial Command Mode Miscellaneous E Maintenance Save and Restart Only at boot up Y Activate by break signal Break signals are caused by sending continuous Spacing values no Start or Stop bits When there is no electricity present
124. in Menu eee a 3 Communication Parameters LO Overview EA Basic Settings Port alias Cl Network Settings Serial Parameters Serial Port Settings A Operation Modes Baud rate Hint f Data bits gw 0 IO Settings stop bits i E E Maintenance Parity Nono amp Save and Restart Flow control RTS CTS FIFO Enable O Disable Interface RS 422 RS 485 Y Data Bits Setting Factory Default Necessity 5 6 7 8 8 Required Stop Bits Setting Factory Default Necessity 1 1 5 2 1 Required Stop Bits will be set to 1 5 when Data Bits is set to 5 bits Parity Setting Factory Default Necessity None Even Odd None Required Space Mark Flow control Setting Factory Default Necessity None RTS CTS RTS CTS Required DTR DSR XON XOFF FIFO Setting Factory Default Necessity Enable Disable Enable Required Each module s serial port provides a 128 byte FIFO both in the Tx and Rx directions Disable the FIFO setting when your serial device does not have a FIFO to prevent data loss during communication Interface Setting Description Necessity RS 232 422 485 RS 232 Required RS 422 485 NPort 5130A 7 6 MiiNePort E2 Web Console Configuration Operation Modes amp Main Menu Overview EA Basic Settings 1 Network Settings Serial Port Settings a E Advanced Settings HA Maintenance Save and Restart Operation Modes Mode
125. ing for Channel 1 is already shown on the screen Note that after you click Submit your configuration is already stored in MiiNePort E2 s memory and won t be erase unless your change the configuration again 3 Main Menu i Operation Modes I Overview FE Basic Settings Mode mese x QU Network Settings Channel 1 TCP Server Serial Port Settings Operation Modes H0 Advanced Settings E Maintenance 1 Save and Restart Channel 2 TCP Client y Click Modify to configure Channel 2 For example if you want to set Channel 2 to Real COM mode you need to finish your Real COM settings and then click Submit Operation Modes Settings OK Your changes have been submitted but not saved Click Save Restart to save your changes and reboot the server Your changes will take effect when the server restarts If you would like to make additional changes remember to save your configuration before restarting the server Back Save Restart b When the confirmation screen appears choose either Save Restart to activate the changes you ve made or Close to do other configurations Besides the configuration settings refer to Chapter 8 NetEZ Technologies for information about the MCSC command format and device system design 7 23 MiiNePort E2 Web Console Configuration Advanced Settings Accessible IP List
126. ion Where should NPort Windows Driver Manager be installed i Setup will install NPort Windows Driver Manager into the following folder To continue click Next If you would like to select a different folder click Browse C Program FlesiNPortDrvManage Browse Atleast 1 6 MB of free disk space is required lt Back Next gt Cancel 4 Click Next to install the program s shortcuts in the appropriate Start Menu folder iG Setup NPort Windows Driver Manager Select Start Menu Folder MN Where should Setup place the program s shortcuts E Setup will create the program s shortcuts in the following Start Menu folder To continue click Next If you would like to select a different folder click Browse NPort Windows Driver Manage o o Browse lt Back Next gt Cancel 6 5 MiiNePort E2 Utility Console and Driver I nstallation 5 The installer will display a summary of the installation options Click Install to begin the installation The setup window will report the progress of the installation To change the installation settings click Back and navigate to the previous screen ie Setup NPort Windows Driver Manager Ready to Install Setup is now ready to begin installing NPort Windows Driver Manager on your computer Click Install to continue with the installation or click Back if you want to review or change any settings Destination location C Program Files
127. ion address index For an MCSC disabled port the channel index is 0 The destination address index is as follows 0 Destination address 1 Alternated address 1 2 Alternated address 2 3 Alternated address 3 Reply parameters TCP destination address and port GT11 0 0 System requests destination address for port 1 GT10192 168 1 2 4001 MiiNePort reports destination address as 192 168 1 2 and port as 4001 TCP max connection Command code TM Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters MiiNePort s TCP maximum connection number 2GTM1 1 System requests maximum connection number for port 1 and channel 1 IGTM04 MiiNePort reports maximum connection number as 4 TCP ignore jammed IP Command code TJ Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters 1 Enable or O Disable 2GT1 2 System requests jammed IP policy for port 1 s channel 2 IGTJO1 MiiNePort reports ignore jammed IP as Enable TCP client local port Command code TL Command parameters Two numbers separated by a semicolon denotes port index and MCSC channel index For MCSC disabled port channel index shall be 0
128. it timeout to be larger than 8 3 ms so in this case it must be greater than or equal to 10 ms If the user wants to send a series of characters in the same packet the serial device attached to the MiiNePort E2 should send that series of characters during a time interval less than the Force transmit timeout for the MiiNePort E2 and the total length of data must be less than or equal to the MiiNePort E2 s internal buffer size The serial communication buffer size for the MiiNePort E2 is 1 KB per port Destination IP address 1 2 3 4 Setting Factory Default Necessity IP address or Domain None Required Name E g 192 168 1 1 Allows the MiiNePort E2 to connect actively to the remote host whose IP address is set by this parameter ATTENTI ON Up to 4 connections can be established between the MiiNePort E2 and hosts The connection speed or throughput may be low if one of the four connections is slow since the 1 slow connection will slow down the other 3 connections ATTENTI ON The Destination IP address parameter can use both IP address and Domain Name For some applications the user may need to send the data actively to the remote destination domain name Designated Local Port 1 2 3 4 Setting Factory Default Necessity TCP Port No 5011 Port 1 Required 5012 Port 2 5013 Port 3 5014 Port 4 Connection control Setting Factory Default Necessity Startup None Any C
129. itional 2 bytes for Delimiter 2 of data is received after receiving the Delimiter Strip Delimiter When the Delimiter is received the Delimiter is deleted i e stripped and the remaining data is transmitted Force transmit Setting Factory Default Necessity 0 to 65535 ms 0 ms Optional MiiNePort E2 Web Console Configuration 0 Disable the force transmit timeout 1 to 65535 Forces the MiiNePort E2 s TCP IP protocol software to try to pack serial data received during the specified time into the same data frame This parameter defines the time interval during which the MiiNePort E2 fetches the serial data from its internal buffer If data is incoming through the serial port the MiiNePort E2 stores the data in the internal buffer the MiiNePort E2 transmits data stored in the buffer via TCP IP but only if the internal buffer is full or if the Force transmit time interval reaches the time specified under Force transmit timeout The optimal Force transmit timeout depends on your application but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits 1 stop bit and no parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is 10 bits 1200 bits s 1000 ms s 8 3 ms Therefore you should set Force transm
130. l network environment For correct gateway IP address information consult your network administrator DNS server 1 DNS server 2 Setting Factory Default Necessity E g 192 168 1 1 IP None Optional addresses of the form x x x 0 and x x x 255 are invalid 7 4 MiiNePort E2 Web Console Configuration Domain Name System DNS is how Internet domain names are identified and translated into IP addresses A domain name is an alphanumeric name such as moxa com that it is usually easier to remember A DNS server is a host that translates the text based domain name into the corresponding numeric IP address which is used to establish a TCP IP connection When the user enters a website address the computer asks a DNS server for the website s IP address to connect to the web server When a DNS server is specified the module acts as DNS client and will allow domain names instead of IP addresses to be used on the web console The following web console fields support the use of domain names TCP Client Destination IP Address and IP Address Report Server Two DNS servers may be specified DNS server 1 and DNS server 2 DNS server 2 is included for use when DNS sever 1 is unavailable Serial Port Settings amp Main Menu CO Overview EA Basic Settings Network Settings Serial Port Settings Communication Parameters Port alias Serial Parameters Baud rate Hint 115200 Operation Modes Data bits a a
131. l with no control ability The serial port parameters will use firmware settings instead of your application program AP settings Application software that is based on the COM driver will receive a driver response of success when the software uses any of the Win32 API functions The firmware will only send data back to the driver on the host Data will be sent first in first out when data is received by the MiiNePort E2 from the Ethernet interface ATTENTION When Max connection is greater than 1 the MiiNePort E2 module will use a multiple connection application i e 2 to 4 hosts are allowed access to the port at the same time When using a multi connection application the module will use the serial communication parameters as defined here in the web console and all hosts connected to the port must use identical serial settings If one of the hosts opens the COM port with different serial settings data will not be transmitted properly Ignore jammed IP Setting Factory Default Necessity Enable Disable Disable Required when Max connection greater than 1 This option determines how the port will proceed if multiple hosts are connected and one or more of the hosts stops responding as the port is transmitting data If you select Disable the port will wait until the data has been transmitted successfully to all hosts before transmitting the next group of data If you select Enable the port will ignore the host t
132. lect data from the same serial device at the same time As illustrated in the figure data transmission proceeds as follows 1 The host connects to the module configured for TCP Server mode 2 Once the connection is established data can be transmitted in both directions from the host to the module and from the module to the host Host TCP Client TCP IP Ethernet Request a connection Proceed with data transmission t SP uineron E2 TCP Server Serial Device with MiiNePort E2 TCP Client Mode In TCP Client mode the module can actively establish a TCP connection to a pre defined host computer when serial data arrives After the data has been transferred the module can be automatically disconnected from the host computer by using the TCP alive check time or Inactivity time settings refer to the following chapters for more details As illustrated in the figure data transmission proceeds as follows 1 The module actively establishes a connection based on the conditions set in the firmware You may let the module connect to a remote host on startup or connect later when data from the serial device arrives 2 Oncethe connection is established data can be transmitted in both directions from the host to the module and from the module to the host Host Server TCP IP Ethernet Request a connection Proceed with data transmission Serial TTL UART
133. library neci java javac target COMPLIER_VER java Execute src jar clean bat to delete all class files 8 8 MiiNePort E2 NetEZ Technologies A In order to reserve more useful EZPage space do not pack the source code into the jar file Step 2 Pack EZPage You could pack all class files in the src jar directory to a jar file or use src jar pack bat to pack all class files as EZpage jar Feiclean bat 1 KB 5 compile bat 1KB COPYING MOXA TXT 2KB E EZPage java 69 KB foldercl gif 1KB folderop gif 1KB E messages properties 1KB aj necijar 85 KB ro ipack bat 1 KB ms JPG 6 KB E VERSION TXT 1 KB ATTENTION 2 To delete all class files after packing them issue the following command src jar clean bat META INF Flclanbat 1 KB S compile bat 1KB E COPYING MOXA TXT 2KB E EZPage java 69 KB 1 foldercl gif 1 KB 1 folderop gif 1 KB Es messages properties 1KB i necijar 85 KB ES pack bat 1KB E ps JPG 6KB E VERSION TXT 1 KB ATTENTION You need to assign the correct target jar file on index htm lt html gt lt applet CODEBASE lt applet gt lt html gt ez_page WIDTH 866 HEIGHT 666 gt 3 Execute the EZPageTool command with the makefs parameter to pack all files in command prompt mode 4 Usage EZPageTool makefs file path file name Example EZPageTool makefs c jar ezpage You will see the following message if the
134. mit timeout The optimal Force transmit timeout depends on your application but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits 1 stop bit and no parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is 10 bits 1200 bits s 1000 ms s 8 3 ms Therefore you should set Force transmit timeout to be larger than 8 3 ms so in this case it must be greater than or equal to 10 ms If the user wants to send a series of characters in the same packet the serial device attached to the MiiNePort E2 should send that series of characters during a time interval less than the Force transmit timeout for the MiiNePort E2 and the total length of data must be less than or equal to the MiiNePort E2 s internal buffer size The serial communication buffer size for the MiiNePort E2 is 1 KB per port MiiNePort E2 Web Console Configuration TCP Client Mode 3 Main Menu i Operation Modes E Overview E Basic Settings Mode TCP Client Network Settings TCP alive check time 7 0 99 min AU Serial Port Settings Inactivity time D 0 65535 ms a Operation Modes Ignore jammed IP OEnable O Disable EA Advanced Settings Destination IP address 1 Port 4001 Accessible IP List Destination IP address 2 Port 4001 A snmp Agent Destination IP address 3 Port 4
135. mmand parameters Port index MCSC channel index and TCP alive check time Parameters are separated by a semicolon For an MCSC disabled port the channel index is 0 Reply parameters N A SRA1 0 5 System sets port 1 s TCP alive check time as 5 for port 1 ISRAOC MiiNePort reports command executed successfully Real COM max connection Command code RM Command parameters Port index MCSC channel index and maximum connection number Parameters are separated by a semicolon For an MCSC disabled port the channel index is 0 Reply parameters N A SRM1 1 4 System sets maximum connection number as 4 for port 1 and channel 1 ISRMO MiiNePort reports command executed successfully A 28 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Real COM ignore jammed IP Command code RJ Command parameters Port index MCSC channel index and ignore jammed IP setting Parameters are separated by a semicolon For an MCSC disabled port the channel index is 0 Ignore jammed IP setting is 1 Enable or O Disable Reply parameters N A SRJ1 2 0 System sets ignore jammed IP policy as Disable for port 1 s channel 2 ISRJO MiiNePort reports command executed successfully Real COM allow Driver Control Command code RD Command parameters Port index MCSC channel index and match bytes Parameters are separated by a s
136. n is enabled 0 otherwise RBA System requests Auto configuration setting for this MiiNePort IRBA01 MiiNePort reports Auto configuration as Enable External reset function Command code BE Command parameters N A Reply parameters 1 if external reset function is enabled O otherwise RBE System requests external reset function setting for this MiiNePort IRBE01 MiiNePort reports Auto configuration as Enable A 36 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set NECI utility accessibility Command code BU Command parameters N A Reply parameters 1 if NECI is enabled O otherwise RBUC System requests NECI setting for this MiiNePort IRBU0O1 MiiNePort reports NECI as Enable IP configuration Command code NC Command parameters N A Reply parameters MiiNePort s IP configuration index as follows 0 Static 1 DHCP 2 DHCP BOOTP 3 BOOTP 4 Autol P 2RNC A System requests IP configuration for this MiiNePort IRNCO0O MiiNePort reports IP configuration as Static IP address Command code NI Command parameters N A Reply parameters MiiNePort s IP address RNI System requests IP address for this MiiNePort IRNI0192 168 127 254 MiiNePort reports IP address as 192 168 127 254 Netmask Command code NM Command parameters N A Reply parameters
137. nance gt gt gt gt Console Settings Firmware Upgrade Configuration Tools Change Password MiiNePort E2 Web Console Configuration Opening Your Brower 1 Open your browser with the cookie function enabled To enable your Internet Explorer for cookies right click on your desktop Internet Explorer icon select Properties click on the Security tab and then select the three Enable options as shown in the figure below General Security content Connections Programs Advanced Settings Select a Web content zone to specify its security settings E Cookies B Allow cookies that are stored on your computer 89 092 om Internet Local intranet Trusted sites Restricted O Enable sites O Prompt Allow per session cookies not stored Internet O Disable This zone contains all Web sites you haven t placed in other zones Enable O Prompt m Security level for this zone a Down loads Move the slider to set the security level for this zone B File download Medium O Disable Safe browsing and still Functional Enable E Prompts before downloading potentially umsafe content Miro do a Unsigned ActiveX controls will not be downloaded 4 b Appropriate for most Internet sites Reset custom settings Reset to Medium e 2 Type 192 168 127 254 in the Address box use the correct IP address if different from the default and then press Enter ATTENTI ON
138. nd executed successfully TCP port Command code TP Command parameters Port index MCSC channel index and TCP local port Every parameter is separated by semicolon For MCSC disabled port channel index shall be 0 Reply parameters N A STP1 0 4100 System sets TCP port as 4100 for port 1 ISTPOJ MiiNePort reports command executed successfully Command code TO Command parameters Two numbers separated by a semicolon denotes port index and MCSC channel index For MCSC disabled port channel index shall be 0 Reply parameters TCP port STO1 0 966 System sets TCP command port as 966 for port 1 ISTOOJ MiiNePort reports command executed successfully Command code TD Command parameters Two numbers separated by a semicolon denotes port index and MCSC channel index For MCSC disabled port channel index shall be 0 Reply parameters 1 Enable or O Disable STD1 0 1J System sets allow driver control policy as enable for portl ISTDOJ MiiNePort reports command executed successfully A 30 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set TCP client connection control Command code TC Command parameters Port index MCSC channel index and client connection control setting Every parameter is separated by semicolon For MCSC disabled port channel index shall be 0 Reply parameters N A
139. o digital input mode D 3 MiiNePort E2 DIO Commands Response Byte Descriptor Value Description 1 Header 2 command number fixed 2 Header 2 version fixed 3 Header 0 1 2 3 command status error code 0 okay 4 5 6 OxFF 4 Header 3 data length fixed Data 0 1 2 3 desired DIO channel 6 Data 0 1 0 channel has been changed to input mode 1 channel has been changed to output mode 7 Data 0 1 this byte is ignored for input mode 0 channel status has been changed to low 1 channel status has been changed to high For example the 7 byte response sequence 2 2 0 3 0 0 0 indicates that DIO 0 has been changed to input mode C Code Example void WriteSingleDIO int port int mode int status DIOPacketStruct packet packet header command 2 write single DIO command packet header version 2 DIO protocol version packet header length 3 data length packet data 0 char port number of the DIO packet data 1 char mode DIO mode packet data 2 char status DIO status send SocketFd char amp packet sizeof DIOHeaderStruct 3 0 Send TCP packet Process th returned data here Read Multiple DI Os Command Byte Descriptor Value Description 1 Header 5 command number fixed 2 Header 2 version fixed 3 Header any this byte is only used in the module s response 4 Header 2 data leng
140. ocess as Delimiter 2 Force Transmit Command code OF Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters MiiNePort s force transmit timeout GOF1 0 System requests port 1 s force transmit timeout for this MiiNePort IGOF00 MiiNePort reports force transmit timeout as 0 sec Real COM TCP alive check time Command code RA Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters MiiNePort s TCP alive check time GRA1 0 System requests port 1 s TCP alive check time for port 1 IGRA05 MiiNePort reports TCP alive check time as 5 min A 11 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Real COM max connection Command code RM Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters MiiNePort s TCP maximum connection number GRM1 1 System requests maximum connection number for port 1 and channel 1 IGRM04 MiiNePort reports maximum connection number as 4 Real COM Ignores Jammed IP Command code RJ Command parameters Two numbers separated by a semic
141. olon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters 1 Enable or O Disable GRJ1 2 System requests jammed IP policy for port 1 s channel 2 IGRJO1 MiiNePort reports ignore jammed IP as Enable Real COM Allows Driver Control Command code RD Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters 1 Enable or 0 Disable GRD1 0 System requests allow driver control policy for port1 IGRDO1 MiiNePort reports allow driver control as Enable RFC2217 TCP alive check time Command code FA Command parameters Two numbers separated by a semicolon denotes port index and MCSC channel index For MCSC disabled port channel index shall be 0 Reply parameters 1 Enable or O Disable GFA1 0d System requests for alive check time for port1 IGFAO7 MiiNePort reports alive check time is 7 A 12 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set RFC2217 local listen port Command code FP Command parameters Two numbers separated by a semicolon denotes port index and MCSC channel index For MCSC disabled port channel index shall be 0 Reply parameters local listen port GFP1 0J System requests for RFC2217 local listen port for port 1
142. ommand executed successfully Save amp Restart Command code SR Command parameters 1 for Save amp Restart 0 for Restart only Reply parameters N A CSR1 System requests to save configuration and restart ICSRO Your configuration is saved and restart MiiNePort server now Load Factory Default Command code LD Note that this command is not applied to the configuration until you save amp restart the MiiNePort Command parameters 1 for All setting 0 for Keep IP setting Reply parameters N A CLDO System requests to load factory default ICLDO System loads factory default successfully A 54 Well Known Port Numbers This appendix is included for your reference Listed below are port numbers that already have a well established use These port numbers should be avoided when assigning a port number to your MiiNePort E2 Series module otherwise you may experience network problems Refer to the RFC 1700 standard for Well Known Port Numbers or refer to the following introduction from IANA e The port numbers are divided into three ranges the Well Known Ports the Registered Ports and the Dynamic and or Private Ports e The Well Known Ports are those from 0 through 1023 e The Registered Ports are those from 1024 through 49151 e The Dynamic and or Private Ports are those from 49152 through 65535 The Well Known
143. ommand parameters The index of accessible IP list from 1 to 16 Reply parameters Return format Mode lP Netmask in the accessible IP list If mode equals 1 it s active otherwise it s inactive RAI12 System requests 1st accessible IP list for this MiiNePort RAIO1 192 168 1 2 255 255 255 0 MiiNePort reports 1st assessible IP list as Active IP address as 192 167 1 2 and Netmask as 255 255 255 0 Auto IP Report Command code NR Command parameters N A Reply parameters MiiNePort s auto IP report setting RNR System requests auto IP report for this MiiNePort IRNRO192 168 1 250 4000 50 MiiNePort reports Auto IP report server as 192 168 1 250 and port as 4000 and report period as 50 Port alias Command code SA Command parameters N A Reply parameters MiiNePort s Port alias RSAC System requests Port alias for this MiiNePort RSAOportie MiiNePort reports Port alias as port1 Baud rate Command code SB Command parameters Port index Reply parameters MiiNePort s Baud rate 7RSB1 System requests port 1 s Baud rate for this MiiNePort RSBO115200 MiiNePort reports Baud rate as 115200 A 40 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Data bits Command code SD Command parameters Port index Reply parameters MiiNePort s Data bits
144. on the data circuit the line is considered to be sending a Break The Break signal must be of duration longer than the time it takes to send a complete byte plus Start Stop and Parity bits amp Main Menu 7 Serial Command Mode E Overview EJ Basic Settings Serial Command Mode EX Advanced Settings Way to enter serial command mode Activate by break signal Accessible IP List SNMP Agent DIO settings Serial Command Mode Miscellaneous Maintenance Save and Restart 7 26 MiiNePort E2 Web Console Configuration Miscellaneous SY Main Menu i 2 a Miscellaneous 1 Overview EA Basic Settings PHY Speed EA Advanced Settings PHY Speed Auto R A Accessible IP List Status 100Mbps Full G SNMP Agent 2 Pin and 10 Settings A Serial Command Mode A Miscellaneous Gratuitous ARP Gratuitous ARP Enabled Send period 300 10 1000 sec Auto IP Report 3 Maintenance Auto report to Port 4002 Save and Restart Auto report period 10 O 99 sec PHY Speed PHY Speed Setting Factory Default Necessity Auto 100 Mbps Full Auto Required Duplex 100 Mbps Half Duplex 10 Mbps Full Duplex and 10 Mbps Half Duplex You can set PHY speed to Auto 100 Mbps Full Duplex 100 Mbps Half Duplex 10 Mbps Full Duplex or 10 Mbps Half Duplex Gratuitous ARP In some applications you may need the MiiNePort to send broadcast packets to update the ARP table on the server If you enable this
145. onal Default 0 The Delimiter Process will be followed regardless of the length of the data packet If the data length in bytes matches the configured value the data will be forced out The data length can be configured for 0 to 1024 bytes Set to 0 if you do not need to limit the length Delimiter 1 Setting Factory Default Necessity 00 to FF 00 for None Optional Delimiter 2 Setting Factory Default Necessity 00 to FF 00 for None Optional Once the MiiNePort E2 receives both delimiters through its serial port it immediately packs all data currently in its buffer and sends it to the MiiNePort E2 s Ethernet port ATTENTION Delimiter 2 is optional If left blank then Delimiter 1 alone trips clearing of the buffer If the size of the serial data received is greater than 1 KB the MiiNePort E2 will automatically pack the data and send it to the Ethernet However to use the delimiter function you must at least enable Delimiter 1 If Delimiter 1 is left blank and Delimiter 2 is enabled the delimiter function will not work properly Delimiter process Setting Factory Default Necessity Do Nothing Do Nothing Optional Delimiter 1 Delimiter 2 Strip Delimiter Do Nothing The data will be transmitted when the Delimiter is received Delimiter 1 or Delimiter 2 The data will be transmitted when an additional byte for Delimiter 1 or an add
146. onfigured in moxattyd cf as in the following example ts 2 respawn usr etc moxattyd moxattyd t 1 Device naming rule For UnixWare 7 UnixWare 2 1 x and SVR4 2 use pts n For all other UNIX operating systems use ttyp n Adding an additional server 1 Modify the text file moxattyd cf to add an additional server User may use vi or any text editor to modify the file For more configuration information look at the file moxattyd cf which contains detailed descriptions of the various configuration parameters 2 Find the process ID PID of the program moxattyd ps ef grep moxattyd 3 Update configuration of moxattyd program kill USR1 PID e g if moxattyd PID 404 kill USR1 404 Execute the moxattyd program again to activate the new settings as follows usr etc moxattyd moxattyd t 1 This completes the process of adding an additional server 6 11 7 Web Console Configuration The web console is the most user friendly way to configure your MiiNePort E2 Series module This chapter introduces the web console function groups and function definitions The following topics are covered in this chapter o o o Opening Your Brower Web Console Fundamentals Basic Settings gt gt gt Network Settings Serial Port Settings Operation Modes Advanced Settings VV YV YV Y Accessible IP List SNMP Agent DIO Settings Serial Command Mode SCM Miscellaneous Mainte
147. or 0 Disable Reply parameters N A SSF1 1 System sets port 1 s FIFO as Enable ISSFO 4 MiiNePort reports command executed successfully Interface Command code SI Command parameters Port index Reply parameters O RS232 or 1 RS485 2wire MiiNePort s Interface 55S11 04 System sets port1 s interface as RS232 ISSIOd MiiNePort reports command executed successfully A 26 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Operation Mode Command code OM Command parameters Port index MCSC channel index and operation mode to set Every parameter is separated by semicolon For MCSC disabled port channel index shall be 0 The operation mode is as following Disable ReamCom RFC2217 TCP server TCP client UDP e modem MCSC NYO OR WI NITR oO Reply parameters N A SOM1 0 2 System sets port 1 s operation mode as RFC2217 ISOMOJ MiiNePort reports command executed successfully Data Packing Length Command code OL Command parameters Port index MCSC channel index and data packing length to set Parameters are separated by a semicolon For an MCSC disabled port the channel index is 0 Reply parameters N A SOL1 0 256 System sets port 1 s data packing length as 256 ISOLO MiiNePort reports command executed successfully
148. ore jammed IP Allow driver control Local TCP port TCP Server v 7 0 99 min 0 0 65535 ms 1 Enable Disable Enable Disable 4001 Command port 966 4 Serial Command Mode m BS Miscellaneous PACO Eig Maintenance Packet length D 0 1024 fia cavetaridlRestark Delimiter 1 00 Hex Enable Delimiter 2 DO Hex Enable Delimiter process Do nothing Force transmit D 0 65535 ms TCP alive check time Setting Factory Default Necessity Optional 0 to 99 min 7 min 0 min TCP connection is not closed due to an idle TCP connection 1 to 99 min The MiiNePort E2 automatically closes the TCP connection if there is no TCP activity for the given time After the connection is closed the MiiNePort E2 starts listening for another host s TCP connection Inactivity time Setting Factory Default 0 to 65535 ms 0 ms Necessity Optional 0 ms TCP connection is not closed due to an idle serial line 0 65535 ms The MiiNePort E2 automatically closes the TCP connection if there is no serial data activity for the given time After the connection is closed the MiiNePort E2 starts listening for another host s TCP connection This parameter defines the maintenance status as Closed or Listen for the TCP connection The connection is closed if there is no incoming or outgoing data through the serial port during the specific Inactivity time If the Inactivity time is set to 0 t
149. ork TFTP server the file is stored on On average it will take less than 5 seconds to conduct a search Your MiiNePort E2 will work properly with its original configuration even if it does not complete the AutoCFG task ATTENTION If you do not want the AutoCFG function to remain active after you ve successfully finished the auto configuration we suggest that you DISABLE the AutoCFG function when you are creating your MiiNePort E2 txt file This will prevent the AutoCFG activity from recurring the next time your device is powered on Refer to Chapter 7 Web Console Configuration for configuration details MCSC Multiple Channel Serial Communication NOTE The Motivation Behind MCSC An embedded device server only provides a limited number of physical serial ports to communicate with the device s main system As a result users with one physical serial port are generally limited to a single application If you want to implement a second third or more serial to Ethernet applications note that the MiiNePort E2 has only one physical serial port additional physical serial ports are needed Unfortunately providing additional physical serial ports increases hardware costs Moxa s MiiNePort E2 s MCSC is designed to solve this dilemma MCSC Multiple Channel Serial Communication is a lightweight pure software solution that enables multiple serial to Ethernet applications all through one physical serial port without any incremental hardw
150. ort s SNMP agent RMS e System requests Enable Disable SNMP agent for this MiiNePort IRMSO1 MiiNePort reports SNMP agent as Enable A 38 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Community String Command code MU Command parameters N A Reply parameters MiiNePort s SNMP Community string RMU System requests SNMP community string for this MiiNePort RMUOpublice MiiNePort reports SNMP community string as public Contact Name Command code MN Command parameters N A Reply parameters MiiNePort s SNMP Contact Name RMN System requests SNMP contact name for this MiiNePort IRMNOs_name MiiNePort reports SNMP contact name as s_name Location Command code ML Command parameters N A Reply parameters MiiNePort s SNMP Location RML System requests SNMP location for this MiiNePort IRMLOs_location MiiNePort reports SNMP location as s_location Enable Disable Accessible IP List Command code AS Command parameters N A Reply parameters Enable 1 or Disable 0 MiiNePort s accessible IP list RNS System requests Enable Disable accessible IP list for this MiiNePort IRNSO1 MiiNePort reports accessible IP list as Enable A 39 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Accessible IP List Command code Al C
151. pability into serial devices NetEZ technology includes 1 2 MiiNePort E2 Introduction SCM Serial Command Mode can be used to easily configure the MiiNePort E2 through serial communication inside the device EZPage Need a module that allows direct communication with the attached serial device Use the MiiNePort E2 s EZPage with Java Applet to create a visual webpage for configuring and communicating with the attached serial device AutoCFG Auto Configuration saves time and effort when setting up the MiiNePort E2 one by one during the device production process 1 3 MiiNePort E2 Introduction MCSC Multiple Channel Serial Communication provides dual connections and dual channels so your device can act as a server and client at the same time Product Specifications Form Factor Type Drop in module Dimensions 29 x 17 x 12 6 mm 1 14 x 0 67 x 0 50 in Weight 5 g System Information CPU 32 bit ARM Core RAM 4 MB built in Flash 2 MB built in Ethernet I nterface Number of Ports 1 Speed 10 100 Mbps auto MDI MDIX Serial I nterface Number of Ports 1 Transmission Format Standard TTL Serial Communication Parameters Data Bits 5 6 7 8 Stop Bits 1 1 5 2 Parity None Even Odd Space Mark Flow Control RTS CTS DTR DSR XON XOFF Baudrate MiiNePort E2 50 bps to 230 4 Kbps suports non standard baudrates MiiNePort E2 H 50 bps to 921 6 Kbps supports non standard baudrates
152. port 1 IRTA05 MiiNePort reports TCP alive check time as 5 minutes TCP port Command code TP Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters TCP port RTP1 0 System requests TCP port for port 1 IRTPO4100 MiiNePort reports TCP port as 4100 TCP command port Command code TO Command parameters Two numbers separated by a semicolon denotes port index and MCSC channel index For MCSC disabled port channel index shall be 0 Reply parameters TCP port RTO1 04 System requests for TCP command port for port 1 IRTOO966 MiiNePort reports TCP command port is 966 TCP server Allow Driver Control Command code TD Command parameters Two numbers separated by a semicolon denotes port index and MCSC channel index For MCSC disabled port channel index shall be 0 Reply parameters 1 Enable or 0 Disable RTD1 0J System requests for allow driver control policy for portl IRTDO1J MiiNePort reports allow driver control is Enable A 46 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set TCP client connection control Command code TC Command parameters Two numbers separated by a semicolon denotes port index and MCSC channel index For MCSC disabled port channel index s
153. ports force transmit timeout as 0 sec Real COM TCP alive check time Command code RA Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters MiiNePort s TCP alive check time RRA1 0 System requests port 1 s TCP check alive time for port 1 IRRA05 MiiNePort reports TCP alive check time as 5 min Real COM max connection Command code RM Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters MiiNePort s TCP maximum connection number RRM1 1 System requests maximum connection number for port 1 and channel 1 IRRMO03 MiiNePort reports maximum connection number as 3 A 44 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Real COM ignore jammed IP Command code RJ Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters 1 Enable or 0 Disable RRJ1 2 System requests jammed IP policy for port 1 s channel 2 IRRJO1 MiiNePort reports ignore jammed IP as Enable Real COM Allow Driver Control Command code RD Command parameters Two numbers separated by a s
154. r an MCSC disabled port the channel index is 0 Reply parameters N A STM1 1 3 System sets maximum connection number as 3 for port 1 and channel 1 ISTMO MiiNePort reports command executed successfully TCP ignore jammed IP Command code RJ Command parameters Port index MCSC channel index and ignore jammed IP setting 0 for disable and 1 for enable Parameters are separated by a semicolon For an MCSC disabled port the channel index is 0 Reply parameters N A 251 1 2 0 System sets ignore jammed IP policy as Disable for port 1 s channel 2 ISTJOC MiiNePort reports command executed successfully TCP inactivity time Command code TV Command parameters Port index MCSC channel index and inactivity timeout setting Parameters are separated by a semicolon For an MCSC disabled port the channel index is 0 Reply parameters N A STV1 0 10 System sets inactivity time as 10 ms for port 1 ISTVOC4 MiiNePort reports command executed successfully UDP destination address Command code UD Command parameters Port index MCSC channel index destination address index 1 to 4 and destination addresses Parameters are separated by a semicolon For an MCSC disabled port the channel index is 0 The destination addresses is formatted as Begin address End address UDP port Reply parameters N A SUD1 0 3 192 168 1 3 19
155. re incorporated into new editions of the publication Technical Support Contact Information Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 www moxa com su ort Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 10 6872 3958 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 Table of Contents 1 INtroductiON momnnnnonnnononnnnnnnncncncacarararnnn nn nnnnn nana nan nn NR ENE ara eaaa anaa aa aaa aaan aaa naana anaana aan aana 1 1 OEI Wisin take dal daa Lakh da a ARM dd Meh eh nes Ani A AAA A ANEA E de EAE ea a cd dace hack cana CG 1 2 PACKAGES Checkliste E RRA 1 2 Product ECATUTES ri tt tt teta 1 2 Prod ct SpecificationS A A A A EA 1 4 MiiNePort E2 Module DIMENSION 0 cece nana nn rra rr r rr rn 1 6 Panel Layout and Pin Assignments 0 cece rre nr nn aaa ene teen 1 6 Evaluation Board Lay oUtiaiinnaaas Aroa 1 6 PIOASSIDNMENES aieia sioi acaiacecaieintilind edlan anne dali dich alan blak ide e N O edad Sad 1 7 Block DIAG FAI eis dr n eaaa aano slang vars wise glee uaiets atada 1 8 LEDO IESO ES it atte 1 9 2 Getting Started aiinsir anaa aaa EWE aAa E nn n nn rn r nena n nena aaa aaa aa 2 1 Wiring Precaution Sisa te de 0 cd daban 2 2 Installing the MiiNePort E2 onto the MiiNePort E2 ST cece eee eee nee tenes 2 2 Selecting the Serial Interface
156. received Although Inactivity time is disabled the MiiNePort E2 will check the connection status between the MiiNePort E2 and remote host by sending keep alive packets periodically If the remote host does not respond to the packet the MiiNePort E2 assumes that the connection was closed down unintentionally The MiiNePort E2 will then force the existing TCP connection to close ATTENTION The Inactivity time should at least be set larger than that of Force transmit timeout To prevent the unintended loss of data due to the session being disconnected it is highly recommended that this value is set large enough so that the intended data transfer is completed MiiNePort E2 Web Console Configuration ATTENTION Inactivity time is ONLY active when TCP connect on is set to Any character Ignore jammed IP Setting Factory Default Necessity Enable Disable Disable Optional Previously when Max connections gt 1 and the serial device is transmitting data if any one of the connected hosts is not responding it will wait until the data has been transmitted successfully before transmitting the second group of data to all hosts Currently if you select Yes for Ignore jammed IP the host that is not responding will be ignored but the data will still be transmitted to the other hosts Packing length Setting Factory Default Necessity 0 to 1024 0 Opti
157. red for digital input channels Under DIO Command the TCP Port setting indicates the port number that will be reserved for DIO commands DIO commands can be used to control and obtain data from the module s DIO channels Refer to Appendix D DIO Commands for additional information E Main Menu ie DIO Settings E Basic Settings DIO number State EX Advanced Settings DIO 0 O Output Low High Accessible IP List DIO 1 O Output Low High SNMP Agent DIO 2 O Output Low High a DIO 3 O Output Low High Serial Command Mode DIO Command Miscellaneous TCP port 5001 9 Maintenance Save and Restart DI is for digital input operation where the channel s status is controlled by an external digital switch DO is for digital output operation where the channel transmits a high or low signal Use Status to control high or low status for digital output channels status setting will be ignored for digital input channels DIO Command DIO Command TCP Port is the port number that will be reserved for DIO commands DIO commands may be used to control and obtain data from the module s DIO channels Refer to Appendix D DIO Commands for additional information on DIO commands 7 25 MiiNePort E2 Web Console Configuration Serial Command Mode SCM SCM Serial Command Mode uses serial communication between the MiiNePort E2 and your device s main system to configure the MiiNePort E2 usually during device operation For more deta
158. rk The MiiNePort Series library can be found in the folder A NECI_ LIB on the Documentation and Software CD included with each module For more information refer to NECI chm in that directory as well as examples located in NECI_LIB VC ConsoleExample
159. rotocol command to set up the module s IP address The ARP command tells your computer to associate the module s MAC address with the intended IP address You must then use Telnet to access the module at which point the module s IP address will be reconfigured ATTENTI ON In order to use ARP both your computer and the module must be connected to the same LAN You may also use a cross over Ethernet cable to connect the module directly to your computer s Ethernet port Your module must be configured with the factory default IP address before executing the ARP command To configure the IP address using ARP follow these instructions 1 Obtain a valid IP address for the module from your network administrator Obtain the module s MAC address from the label on the module 3 Execute the arp s command from your computer s MS DOS prompt by typing arp s lt new IP address gt 00 90 E8 tt tt tt For example arp s 192 168 200 100 00 90 E8 00 00 00 In this example 192 168 200 100 is the new IP address and 00 90 E8 00 00 00 is the module s MAC address as obtained in steps 1 and 2 4 Execute a special Telnet command by typing telnet lt new IP address gt 6000 For example telnet 192 168 200 100 6000 5 2 MiiNePort E2 Initial I P Address Configuration After issuing this command a Connect failed message will appear After the module reboots its IP address will be updated to the new address and you can reconnect the module usin
160. rt is 1234 DIO initial mode Command code PM Command parameters DIO port index For MiiNePort E2 the index is as following Index DIO port MiiNePort E2 PIN number 0 DIOO PIN15 1 DIO1 PIN16 2 DIO2 PIN17 3 DIO3 PIN18 Reply parameters 1 output or O input note that for MiiNePort E2 this configuration is available if specific PIN function is set to DIO RPM1J System requests DIO1 s initial mode for this MiiNePort IRPMO1 MiiNePort reports DIO1 s initial mode is output A 49 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set DI O initial state Command code PS Command parameters DIO port index For the MiiNePort E2 the index is as follows Index DIO port MiiNePort E2 PIN number 0 DIOO PIN15 1 DIO1 PIN16 2 DIO2 PIN17 3 DIO3 PIN18 Reply parameters 1 high or 0 low note that this function is configuration only if specific DIO port is set to initial output RPSO System requests DIO0 s initial state for this MiiNePort IRPSOO MiiNePort reports DIOO s initial state as low Serial command mode trigger Command code CT Command parameters N A Reply parameters serial command mode trigger index as shown in the following table Disabe H W control pin DIO1 Activated by characters WIN R O Activated by break signal
161. s ARP as Enable and send period as 300 sec Command Code for Setting the Configuration Device Name Command code BN Command parameters The new device name for the MiiNePort Reply parameters N A SBNMiiNePort Office System sets the device name as MiiNePort Office IGBNO MiiNePort reports command executed successfully Password Command code BP Command parameters MiiNePort s console password Reply parameters N A SBP1234 System sets console password as 1234 for this MiiNePort ISBPO MiiNePort reports command executed successfully A 19 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Web console Command code BH Command parameters 1 and web console TCP port to enable web console or O to disable it Reply parameters N A 75BH1 80 ISBHO System sets http console as Enable and http port as 80 for this MiiNePort MiiNePort reports command executed successfully Telnet console Command code BT Command parameters 1 and telnet console TCP port to enable telnet console or O to disable it Reply parameters N A SBT1 23 System sets telnet console as Enable and telnet port as 23 for this MiiNePort ISBTO MiiNePort reports command executed successfully Auto configuration Command code BA Command parameters 1 if Auto configuration i
162. s enabled O otherwise Reply parameters N A 2SBA1 System sets auto configuration as Enable for this MiiNePort ISBAO MiiNePort reports command executed successfully External reset function Command code BE Command parameters 1 if external reset function is enabled O otherwise Reply parameters N A 7SBE1 System sets external reset function as Enable for this MiiNePort ISBEO MiiNePort reports command executed successfully A 20 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set NECI utility accessibility Command code BU Command parameters 1 if NECI is enabled O otherwise Reply parameters N A SBU1 System sets NECI setting as Enable for this MiiNePort ISBUO MiiNePort reports command executed successfully IP configuration Command code NC Command parameters MiiNePort s IP configuration index as shown in the following table Reply parameters N A 0 Static 1 DHCP 2 DHCP BOOTP 3 BOOTP 4 AutolP SNCO System sets IP configuration as Static ISNCO MiiNePort reports command executed successfully IP address Command code NI Command parameters MiiNePort s IP address Reply parameters N A SNI192 168 1 2 System sets IP address as 192 168 1 2 ISNIO MiiNePort reports command executed successfully Netmask
163. s where you should install the module onto the evaluation board shown in the below figure When attaching the module to the evaluation board make sure the 8 pins on the module is securely plugged into the 8 pin headers on the evaluation board After the module is installed connect the power supply network and serial device to the evaluation board 2 2 MiiNePort E2 Getting Started Selecting the Serial I nterface The MiiNePort E2 module comes with standard TTL serial signal input but for your evaluation environment the MiiNePort E2 ST has an RS 232 and RS 485 interface for you to choose from Depending on the serial interface of the device to be connected to the evaluation board you can choose between RS 232 and RS 485 by putting a 6 pin jumper on the evaluation board JP13 for RS 232 and J14 for RS 485 as shown in figure below Connecting the Power Connect the 12 48 VDC power line with the evaluation board s power jack If the power is properly supplied the power LED D14 as shown in the following figure on the evaluation board will show a solid green color until the system is ready at which time the ready LED on the module will show a solid green color Connecting to the Network To connect to the network for testing and development purposes plug the Ethernet cable into the RJ 45 jack on the evaluation board If the cable is properly connected the LED will indicate a valid connection to the Ethernet as follows
164. sed with a typical modem No AT command Description Remarks ATA Answer manually ATD lt IP gt lt Port gt Dial up the IP address Port No ATE ATEO Echo OFF ATE1 Echo ON default 4 ATH ATHO On hook default ATH1 Off hook 5 ATI ATIO ATI1 ATI2 Modem version reply OK only 6 ATL Speaker volume option reply OK only 7 ATM Speaker control option reply OK only 8 ATO On line command 9 ATP ATT Set Pulse Tone Dialing mode reply OK only 10 ATQO ATQ1 Quiet command default ATQO 11 ATSr n Change the contents of S register See S registers 12 ATSr Read the contents of S register See S registers 13 ATV Result code type ATVO for digit code ATV1 for text code 0 OK 1 connect default 2 ring 3 No carrier 4 error 14 ATZ Reset disconnect enter command mode and restore the flash settings 15 AT amp C Serial port DCD control AT amp CO DCD always on AT amp C1 DTE detects connection by DCD on off default 16 AT amp D Serial port DTR control AT amp DO recognize DTE always ready AT amp D1 AT amp D2 reply DTE when DTR On default 17 AT amp F Restore manufacturer s settings 18 AT amp G Select guard time reply OK only 19 AT amp R Serial port RTS option command reply OK only 20 AT amp S Serial port DSR control reply OK only 21 AT amp V View settings 22 AT amp W Write current settings to flash for next boot up 7 21
165. ss End address port RUD1 0 3 System requests UDP destination address 3 for port 1 RUDO192 168 1 3 192 168 1 8 4001 MiiNePort reports UDP destination address is from 192 168 1 3 to 192 168 1 8 and port as 4001 A 48 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set UDP local listen port Command code UP Command parameters Two numbers separated by a semicolon denote port index and MCSC channel index For an MCSC disabled port the channel index is 0 Reply parameters local listen port RUP1 0 System requests UDP local listen port for port 1 RUP4001 MiiNePort reports UDP local listen port as 4001 E modem TCP alive check time Command code EA Command parameters Two numbers separated by a semicolon denotes port index and MCSC channel index For MCSC disabled port channel index shall be 0 Reply parameters 1 Enable or 0 Disable REA1 0J System requests for alive check time for portl REAOS5SJ MiiNePort reports alive check time is 5 E modem local listen port Command code EP Command parameters Two numbers separated by a semicolon denotes port index and MCSC channel index For MCSC disabled port channel index shall be 0 Reply parameters local listen port REP1 0J System requests for E modem local listen port for port I IREP012344 MiiNePort reports E modem local listen po
166. sts Enable Disable accessible IP list for this MiiNePort IGAS01 MiiNePort reports accessible IP list as Enable Accessible I P List Command code Al Command parameters The index of accessible IP list from 1 to 16 Reply parameters Return format Mode IP Netmask in the accessible IP list If mode equals to 1 it is active otherwise it is inactive GAI1 System requests 1st accessible IP list for this MiiNePort IGAI0O1 192 168 1 2 255 255 255 0 MiiNePort reports 1st accessible IP list as Active IP address as 192 167 1 2 and Netmask as 255 255 255 0 Auto IP Report Command code NR Command parameters N A Reply parameters MiiNePort s auto IP report setting 2GNR A System requests auto IP report for this MiiNePort GNRO192 168 1 250 4000 50 MiiNePort reports Auto IP report server as 192 168 1 250 and port as 4000 and report period as 50 Port alias Command code SA Command parameters Port index Reply parameters MiiNePort s Port alias GSA1 System requests port 1 alias for this MiiNePort IGSAOport1 MiiNePort reports Port alias as port1 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Baud rate Command code SB Command parameters Port index Reply parameters MiiNePort s Baud rate GSB1 System requests port 1 s Baud rate for this
167. t If the data length in bytes matches the configured value the data will be forced out The data length can be configured for 0 to 1024 bytes Set to 0 if you do not need to limit the length Delimiter 1 Setting Factory Default Necessity 00 to FF 00 for None Optional Delimiter 2 Setting Factory Default Necessity 00 to FF 00 for None Optional Once the MiiNePort E2 receives both delimiters through its serial port it immediately packs all data currently in its buffer and sends it out the MiiNePort E2 s Ethernet port ATTENTION Delimiter 2 is optional If left blank then Delimiter 1 alone trips clearing of the buffer If the size of the serial data received is greater than 1 KB the MiiNePort E2 will automatically pack the data and send it to the Ethernet However to use the delimiter function you must at least enable Delimiter 1 If Delimiter 1 is left blank and Delimiter 2 is enabled the delimiter function will not work properly Delimiter process Setting Factory Default Necessity Do Nothing Do Nothing Optional Delimiter 1 Delimiter 2 Strip Delimiter Do nothing The data will be transmitted when the Delimiter is received Delimiter 1 or Delimiter 2 The data will be transmitted when an additional byte for Delimiter 1 or an additional 2 bytes for Delimiter 2 of data is received after receiving the Delimiter Strip Delimiter
168. th fixed 5 Data 0 1 2 starting DIO channel number 6 Data 1 2 3 ending DIO channel number This command requests the status of a range of DIO channels specified in bytes 5 and 6 For example the 6 byte command sequence 5 2 0 2 0 2 requests the status of DIO channels 0 through 2 MiiNePort E2 DIO Commands Response Byte Descriptor Value Description 1 Header 5 command number fixed 2 Header 2 version fixed 3 Header 0 1 2 3 command status error code 0 okay 4 5 6 OxFF 4 Header 4 6 8 data length depends on the number of DIO channels requested 5 Data 0 1 1st requested DIO channel O channel is in input mode 1 channel is in output mode 6 Data 0 1 1st requested DIO channel 0 channel status is low 1 channel status is high 7 Data 0 1 2nd requested DIO channel O channel is in input mode 1 channel is in output mode 8 Data 0 1 2nd requested DIO channel 0 channel status is low 1 channel status is high 9 Data 0 1 3rd requested DIO channel optional O channel is in input mode 1 channel is in output mode 10 Data 0 1 3rd requested DIO channel optional 0 channel status is low 1 channel status is high 11 Data 0 1 4th requested DIO channel optional O channel is in input mode 1 channel is in output mode 12 Data 0 1 4th requested DIO channel optional 0 channel status is low 1 channel status is high For example the 10 byte response 5 2 0
169. the module will return the entire command as its response but with the third byte changed according to the following status error codes Command error may be unknown Packet too short error D 101 WN OxFF other unknown error ATTENTION DIO command data is transmitted as values rather than text strings A value of 1 would be transmitted as 0x01 C Code Example define DIO Header format typedef struct _DIO_Header_Struct char command Version error not supported by this version Length error the length member does not match the attached data Operation error invalid status or invalid mode DIO number error might not support requested DIO number char version This specification is version 2 char status char length DIOHeaderStruct pDIOHeaderStruct define DIO Packet format Used for Command and ACK packet typedef struct _DIO Packet_Struct DIOHeaderStruct header Char data 255 DIOPacketStruct pDIOPacketStruct Read Single DIO Command Byte Descriptor Value Description 1 Header 1 command fixed 2 Header 2 version fixed 3 Header any this byte is only used in the module s response 4 Header 1 data length fixed 5 Data 0 1 2 3 desired DIO channel For example the 5 byte command sequence 1 2 0 1 0 requests the status of DIO 0 MiiNePort E2 DIO Commands Response Byte Descriptor Value
170. tial mode Command code PM Command parameters DIO port index and initial mode 0 for input and 1 for output separated by semicolon For MiiNePort E2 the index is as following Index DIO port MiiNePort E2 PIN number 0 DIOO PIN 15 1 DIO 1 PIN 16 2 DIO 2 PIN 17 3 DIO 3 PIN 18 Note that this configuration is valid only if related PIN function is set to DIO Reply parameters N A SPMO 14d System sets dio0 mode as output for this MiiNePort ISPMOd MiiNePort reports command executed successfully A 33 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set DI O initial state Command code PS Command parameters DIO port index and initial output state 0 for low and 1 for high Note that this configuration is valid only if DIO initial mode is set to output Reply parameters N A SPSO 1 System sets dio0 state as high for this MiiNePort ISPSO MiiNePort reports command executed successfully Serial command mode trigger Command code CT Command parameters serial command mode trigger index as shown in the following table Note that this configuration is valid only if port 1 s operation mode is not set to MCSC Reply parameters N A 0 Disabe 1 H W control pin DIO1 2 Activated by characters 3 Activated by break signal SCT2 System sets serial command mode as Activate by characters
171. tion making it possible to offer speedier delivery UDP also allows multicasting of data to groups of IP addresses Real COM Mode Real COM mode allows users to continue using software that was written for pure serial communications applications Each module comes equipped with COM drivers for Windows systems 95 and above The module s serial port is mapped by the driver to an IP address and port number The driver intercepts data sent to the host s COM port packs it into a TCP IP packet and then redirects it through the host s Ethernet card At the other end of the connection the module accepts the Ethernet frame unpacks the TCP IP packet and then transparently sends the data to the attached serial device The driver thus establishes a transparent connection between the host and serial device allowing the host to treat the networked device as if it were directly attached Data Transmission Host COM 3 IP Port TCPAP Ethernet MiiNePorf E2 UART Serial Device with MiiNePort E2 TCP Server Mode In TCP Server mode the module is assigned a unique IP address and port number on the TCP IP network The module waits passively to be contacted by the host computer allowing the host computer to establish a connection with and obtain data from the serial device This operation mode also supports up to 4 simultaneous 3 2 MiiNePort E2 Choosing the Proper Operation Mode connections so that multiple hosts can col
172. tory Default Necessity 00 to FF None Optional Delimiter 2 Setting Factory Default Necessity 00 to FF None Optional Once the MiiNePort E2 receives both delimiters through its serial port it immediately packs all data currently in its buffer and sends it out the MiiNePort E2 s Ethernet port Delimiter process Setting Factory Default Necessity Do Nothing Do Nothing Optional Delimiter 1 Delimiter 2 Strip Delimiter Do Nothing The data will be transmitted when the Delimiter is received Delimiter 1 or Delimiter 2 The data will be transmitted when an additional byte for Delimiter 1 or an additional 2 bytes for Delimiter 2 of data is received after receiving the Delimiter Strip Delimiter When the Delimiter is received the Delimiter is deleted i e stripped and the remaining data is transmitted Force transmit Setting Factory Default Necessity 0 to 65535 ms 0 ms Optional O Disable the force transmit timeout 1 to 65535 Forces the MiiNePort E2 s TCP IP protocol software to try to pack serial data received during the specified time into the same data frame This parameter defines the time interval during which the MiiNePort E2 fetches the serial data from its internal buffer If data is incoming through the serial port the MiiNePort E2 stores the data in the internal buffer The MiiNePort E2 transmits data stored in the buffer vi
173. trieving Running Configuration Device Name Command code BN Command parameters N A Reply parameters MiiNePort s name RBN System requests configured device name for this MiiNePort IRBNOMiiNePort_9527 MiiNePort reports device name as MiiNePort_9527 Console Password Command code BP Command parameters N A Reply parameters MiiNePort s console password RBPH System requests console password for this MiiNePort I RBP01234 MiiNePort reports console password as 1234 A 35 MiiNePort E2 Introduction to SCM Serial Command Mode Command Set Web console Command code BH Command parameters N A Reply parameters 1 and web console TCP port separated by a semicolon if web console is enabled or a O if it is disabled RBHe System requests http console setting for this MiiNePort IRBHO1 80 MiiNePort reports http console as Enable and http port as 80 Telnet console Command code BT Command parameters N A Reply parameters 1 and telnet console TCP port separated by a semicolon if telnet console is enabled or a 0 if it is disabled RBT System requests telnet console setting for this MiiNePort IRBTO1 23 MiiNePort reports telnet console as Enable and telnet port as 23 Auto configuration Command code BA Command parameters N A Reply parameters 1 if Auto configuratio
174. vice manufacturing process To use AutoCFG follow the steps described below 2N NOTE AutoCFG is enabled in Moxa s factory default settings If you want to disable AutoCFG see Chapter 7 Web Console Configuration Maintenance Configuration Tool Auto Configuration Step 1 Export the configuration Refer to Chapter 7 Web Console Configuration gt Maintenance gt Configuration Tool gt Configuration Export After you export your configuration save the configuration to MiiNePortE2 txt which contains all of the MiiNePort E2 module s settings Step 2 Set up a TFTP server on the network where you plan to conduct the AutoCFG task on your device production line Set your TFTP server s IP address as 169 254 x x 16 Next save the previously saved MiiNePortE2 txt file under the root directory of the TFTP server At this point the AutoCFG working environment should be ready NOTE Quite a bit of freeware that can help you easily set up a TFTP server can be found on the Internet Step 3 AutolP protocol will automatically assign your MiiNePort E2 modules with a temporary IP address Step 4 Your MiiNePort E2 modules will actively send out a broadcast packet asking if there is a TFTP server on the same subnet that has a file named MiiNePortE2 txt Step 5 Your TFTP server will respond to the broadcast packet and your MiiNePort E2 modules will automatically download the MiiNePortE2 txt from the TFTFP server Step 6 Your MiiNePort E2 mo
Download Pdf Manuals