Home
2. Eco - FunkyHeat
Contents
1. The Control Centre will emit signals to the Receiver asking to turn off the heating device Yellow LED on the Receiver flashes means Receiver has received the signals Green LED turns off means heating device is deactivated OPERATION 1 Configuration Menu The configuration menu allows you to set certain thermostat operating characteristics to your system or personal requirements Shortly press button to make sure the thermostat is in anti freeze mode Hold button 3 for 3 seconds to enter the configuration menu The display will show the first item in the configuration menu Press button 3 to shift to the next menu item Use A or Vto select To exit the menu press button revert to the anti freeze mode Press button revert to the program operation If no buttons are pressed within 20 second the thermostat will 4 8 COMFORT HEATING exit the menu To revert to factory default setting push A or V button in a same time for 3 seconds Display will show DEF blinking 3 times and return to Menu item indicates all the configuration setting has reverted to factory default setting Step Press buttons Displayed factory default PressA or Vto select Descriptions 1 01 0 3 3 Select temperature display adjustment higher or lower 2 02 35C 18 C 64F 35C 95F Select maximum setting temperature limitation 3 03 5T 5C 41F 20C 68F Select minimum setting
2. building and electrical codes and ordinances This thermostat has a removable fuse to protect the system from damage If system is not operating properly check wiring and replace fuse if necessary Use this thermostat only as described in this manual 1 8 COMFORT HEATING Commissioning Hold the O syi switch of the SAS2010DE over 3 sec LED of indicator lit up means for commissioning Hold the buutom of the SAS908WHB 7 DF1 over 3 sec in standby mode Begin launching debug command Receiving part of code indicator lit up finish commissioning Return code value LED of indicator lit up 4 times If the lights flashing said commissioning not succeed without Error Code 1 Low battery power alarm When the battery power and the battery power low battery low power alarm Battery alarm sign J blink 2 Communication impassability alarm When the thermostat launch stop output or start output Receiving no boot or not to receive signals can t return Display section E1 flashing alarm E1Communication error alarm Means to send data confiscated E2 alarm means receiving module limited when temperature didn t answer the external temperature probe E3 alarm means that receive limited the temperature when no external temperature probe detection limit temperature higher temperature than value E4 alarm means that receive limited the temperature when no external temperature probe detection temperature below the limit temperature value Control
3. necessary until a comfortable indoor climate has been reached As soon as the solid areas have warmed up comfortable warmth will spread throughout the room and then you can reduce the running time of your heater to the minimum The thermostat set if supplied will control this for you To enjoy the comfortable warmth to its fullest we recommend that you install a high guality control thermostat if you have not purchased this already then please contact a specialised dealer or service company Funkyheat Safety Instructions e The heating element must not be installed directly below a wall socket e The installation of an infrared heater in wet rooms rooms with shower bathtub or swimming pool as well as in public places may only be done by a specialised installation company taking into account the appropriate standards and norms of the country concerned e The infrared heater may only be connected to alternating current 230 Volt 50Hz e The infrared heater must not be exposed to excessive moisture e Do not put objects on the infrared heater and do not cover the infrared heater This will cause a risk of overheating e The infrared heater is equipped with a safety temperature limiting device which turns off the heater in case of overheating and then automatically turns it on again after is has cooled e It must be possible to switch off the heater either by switch on the socket or fused spur or by the thermostat if
4. supplied with the thermostat set and secure the grommet in place with the supplied nut Connect the neutral and live wires to the connections marked N neutral and L Live to the connectors indicated as POWER inside the receiver Leave the earth cable disconnected 6 Connect the two earth wires together using an insulated connector block 7 Replace the cover to the receiver and fix to the back of the heater if desired 8 You now need to pair the heater This is done automatically but you must ensure that the display shows a snowflake icon for this to happen 9 The wireless controller can be placed wherever in the room you feel most appropriate and can be moved as you wish It is sensible to try and place at shoulder height and away from other heat sources such as TV or windows since the temperature is measured by this unit and it will tell the heater to switch on or off as required The preparation of the heater can now be completed by fitting a 13amp UK plug or hardwiring the heater to a fused spur which must be done by a gualified electrician The heater can now be paired with the wireless thermostat controller full details for the controller can be found in the appendix of this manual Cleaning and Care Before cleaning always disconnect the main power plug To clean you should use a smooth and damp cloth and a little washing up liguid detergent Never clean the infrared heating element and the power supply cables
5. A 250VAC e Room temperature setting range 5 C 35 C 41 F 95 F O Accuracy ummmmmmmm mummun rene eee 1 F or0 5 C e Dimensions cccce cece eee ees Control Centre 115mm 90mm 28mm Receiver 113mm 82mm 30mm FEATURE Can be placed anywhere in the home to detect and control the temperature of an area of the user s choice Not limited by power control wiring locations Link with the Receiver via RF Control distance 100M open site Large LCD display The screen displays the set temperature and the room temperature also time simultaneously Permanent user setting and program setting retention during power loss Optional temperature display of Celsius or Fahrenheit scale Both Vacation mode and hold duration mode available for comfort and energy saving Optional programming Period 7 individual day or Separate 5 day weekday and 1 day 1 day Saturday Sunday programming with 4 or 6 separate time temperature periods per day Display temperature recalibrates Low battery indication Anti freezing protection Pump protection available IMPORTANT SAFETY INFORMATION Always turn off power at the main power source by unscrewing fuse or switching circuit breaker to the off position before installing removing cleaning or servicing this thermostat Read all of the information in this manual before installing this thermostat Only a professional contractor should install this thermostat All wiring must conform to local and national
6. INSTRUCTION MANUAL Funkyheaf SMART EFFICIENT HEATING ECO RANGE FAR INFRARED HEATER Sold amp Distributed in the UK amp Ireland by Funkyheat Ltd The Carlile Institute Huddersfield Road Meltham HD9 4AE www funkyheat co uk This appliance complies with European Directives EN60335 1 EN60335 2 30 EN62233 Funkyheat CONTENTS Introduction 3 Safety Instructions 4 Installation 6 Installing the thermostat receiver 7 Cleaning and Care 8 Disposal 8 Appendix 9 Funkyheat Introduction In this manual there is important information for the installation of your infrared heater You have acguired an ecologic economic heater and are thereby making an effective contribution in saving the environment The infrared heating system proves itself through simple installation flexibility in the assembling and freedom from maintenance So you can enjoy long use of your infrared heater To ensure your safety please carefully read the instructions before installation Keep this manual at hand and never sell on or give this infrared heater to anyone without the manual This infrared heater does not work on the principle of convection heat but is a radiant heater Therefore it is possible when first switching on that cold areas furniture walls ceiling and floors need to be warmed up first If you don t immediately have a comfortable feeling of warmth then let the heater run for several hours or even several days if
7. accordance with the voltage information on the type plate verso If you notice damage do not install the heater contact your specialist dealer We recommend that you do not throw away the original package of the device Store the original package for possible transport Remove the existing EU plug by cutting this off then proceed to install the thermostat receiver details below Funkyheat Installing the thermostat receiver Please find below instructions for the thermostat set for your IR Heaters The thermostat set should only be connected by a competent person and if you are in any doubt we recommend that this is done by a gualified electrician This thermostat is very advanced and will allow you to vary your programmes for the heater throughout the day week The receiver needs to be connected to the power cable of the heater 1 Decide whether you want the receiver to be visible or hidden behind the panel heater 2 Cutthe power cable so that you have enough to feed through to the receiver 3 Feedthe power cable through the plastic grommet supplied with the thermostat set and secure the grommet in place with the supplied nut 4 Connect the neutral and live wires from the heater to the connections marked N neutral and L Live to the connectors indicated as LOAD inside the receiver Leave the earth cable disconnected 5 Taking the cable that you have cut off feed the power cable through the plastic grommet
8. centreinstal 1 Remove 2 screws from the bottom of thermostat See Figure 6 Gently pull the control panel straight off the base Forcing or prying on the f mounting screw thermostat will cause damage to the unit 2 Push power base into wall 3 Using two mounting screws mount the power 18 base to the wall Place a level against bottom of base adjust until level and then tighten screws osure Leveling is for appearance only and will not a affect thermostat operation 4 Replace control panel on the power base and fix sorewed connection power base and control panel by removed two screws in item 1 i Receiver install mann A aa 2 8 Screws for mounting thermostat to conduit box COMFORT HEATING KEYBOARD DISPLAY AND SWITCH DESCRIOPTION OF CONTROL CENTRE 1 2 3 4 sai al ini 11 12 13 14 SESCS0000068686060 amp Power on anti freezing off button Time setting button Program setting button Program run confirmation button Reset button Raise Temperature setting button Lower Temperature setting button Shows current day or days being programmed Shows current time or times being programmed Am Morning Pm Afternoon Days Nr of days Hours Nr of hours Shows setting temperatu
9. erminate the anti freezing mode and return to normal operation mode 2 Program operation and Hold temperature operation Momentarily press shift between program operation and hold temperature operation shows when thermostat is in program operation Thermostat controls the heating system by presetting program See Planning your program section shows when thermostat is in hold temperature operation The thermostat will hold the room temperature at the selected setting 3 Temperature override During program operation Press A or V until the temperature you want is displayed shows in temperature override The thermostat will override the current programming and keep the room temperature at the selected temperature until the next program period begins Then the thermostat will automatically revert to the program 4 Vacation Temperature hold i Continue pressing button 8 over 3 seconds until display will show indicates you have now entered into vacation hold Use time key 2 or to select the number of the days from 1 to 99 days during your vacation you can use A or Vto adjust the temperature during your holiday Push button to revert to program operation To the end of vacation time it will automatically return to the program is running In the vacation mode Push button to revert to program operation Vacation factory set temperature is 10 C 5 Reset operation If the display is abnormal press the Reset button by usi
10. ing start time and temperature Use the table to plan your program time periods and the temperatures you want during each period Fill in the complete table to have a record of your program Heating Schedule Plan Factory default program setting Wake up Out lt lt Back lt Out 0 Back Sleep door home door home 6 00 21 C 8 00 16 5 C 12 00 21 C 14 00 16 5 C 18 00 21 C 22 00 16 5 C Enter Heating Program 1 Press once 1 indicating Monday program will appear in the display Also be displayed are the currently programmed start times for the Ist heating period and the currently programmed temperature flashing icon indicates 1 program period Get up setting If the display shows 12345 indicating that the 5 day program will be modified you have a 5 1 1 day model See configuration menu item 8 2 Press A or V to change the displayed temperature to your selected temperature for the 1st heating program period 3 Press once the programmed time will flash Press A or V until your selected time appears The time will change in 15 minute increments When your selected time is displayed press TIME again to return to the change temperature mode 4 Press once icon2 program period Go out display the currently programmed start time and set point temperature for the 2nd heating program period will appear 5 Repeat steps 3 and 4 to select the sta
11. me you press button 3 the next heating period time and temperature will be displayed in seguence for weekday then Saturday and Sunday program periods you may change any time or temperature during this procedure 2 Press button to begin program operation CUSTOMER ASSISTANCE After reading this guide if you have any guestion about the operation of your thermostat please contact your installer or service provider 8 8
12. ng a fine probe such as a straightened paper clip to gently push the Rest button This will reset the thermostat 3 Setcurrent day and time 1 Press button The display will show the hour flashing 2 Press and hold either A or V until you reach the correct hour and AM or PM designation AM begins at night PM begins at noon 3 Press button once again The display will only show minutes flashing 4 Press and hold either A or V until you reach the correct minutes 5 Press button once again The display will show the day of the week flashing 6 Press A or V until you reach the correct day of the week Press button once The display will show the correct day of the week and the time If no keys are pressed within 20 seconds the thermostat will revert to program operation 4 Planning your program 6 8 COMFORT HEATING Look at the factory preprogrammed times and temperatures shown in the sample schedule If this program will suit your needs simply press the button to begin running the factory preset program If you want to change the preprogrammed time and temperature follow these steps Determine the times period and temperature for your program You must program four periods for each day You can choose heating temperature and start time independently for example you may select 5 00 AM and 70 F as the weekday 1 period heating start time and temperature and also choose 7 00 AM and 76 F and the weekday 1 period cool
13. re Low battery indicator Shows temperature display in C or F time to get up time to go out in the morning time to come back in the morning gt time to go out in the afternoon time to return in the afternoon time to go to bed Low battery indicator System in Anti freezing mode System in heating mode Flashes when there is a call for heating Manual temperature overide operation Program operation IRIS Indicates a malfunction with the system Program setting mode Shows current readout temperature l Vacation mode indication Hold temperature indication COMFORT HEATING RAE SZ Power 100 240VAC 50 60HZ Heat Load Imax 250VAC 16A Sensor Heat Load Select Button Indicator A RED GREEN LED Indicator B GREEN LED Indicator C YELLOW LED CHECK THERMOSTAT OPERATION The unit will be controlled via air sensor in the Control Centre and the Control Centre will determine to activate deactivate heating system by comparing set temperature with room temperature Press A to adjust Control Centre setting above room temperature 1 C in fast heating mode or 3C in slow heating mode See configuration menu item 5 The Control Centre will emit signals to the Receiver asking to turn on the heating device Yellow LED on the Receiver flashes means Receiver has received the signals Green LED turns on means heating device is energized Press V to adjust Control Centre setting below room temperature
14. room temperature 6 Select pump protection mode For hot water heating installation it is recommended to activate the pump at least 15 second every 24 hours in order to avoid any seizing Select PP will activate pump protection mode Select OO will cancel the function it shows heating out normally When thermostat activating the pump in the display will blink Heating output will be automatic operated as your setting 7 Time display To select 12 hours or 24hours display 8 There are 2 options for how to program the day in one week 7 You can program in 7 individual days Factory default is 7 3 You can program in 5 weekday and 1Saturday and 1 Sunday 0 Youcan set up not programming model 9 Select separate time temperature periods per day P4 indicate 4 period programming per day P6 means 6 period programming per day 5 8 COMFORT HEATING 2 Manual Operation 1 On Anti freezing mode You can press power button to activate the anti freezing mode The unit only displays Clock time Weekday and Room temperature The default set temperature for anti freezing mode is 5 C During anti freezing mode if room temperature is below 5C the unit will activate the heating system till room temperature reach to 9 C For hot water installations if PP had been selected See Configuration menu item 6 the unit will activate the pump at least 15 seconds every 24 hours in order to avoid any seizing Press power button again will t
15. rt time and heating temperature for the 2nd heating program period 6 Repeat steps 3 through 5 for the 3rd 4th 5th 6th heating program periods If 4 period per day selected in the configuration menu item 9 only 4 period can be programmed each day 7 Press 3 once 2 indicating Tuesday program will appear in the display along with the start time for the 1st heating period and the currently programmed temperature If the display shows 6 indicating that Saturday program will be modified in 5 1 1 day model 8 Repeat steps 3 through 6 to complete Tuesday 7 day model or Saturday 5 1 1 day model heating programming 9 Continue entering each day s programming until all heating periods time and temperatures have been entered 10 When you have completed entering your heating program press D 7days program refer to above REVERT TO FACTORY DEFAULT PROGRAM SETTING 7 8 COMFORT HEATING Press 3 button enter into program setting Press A or V at the same time for 3 seconds Display will show DEF blinking for 3 times and back to program setting Press the button to begin running the factory preset program If no keys are pressed within 20 sec the thermostat will revert to program operation CHECK YOUR PROGRAMMING Follow these steps to check your thermostat programming one final time before beginning thermostat operation 1 Press button 3 to view the 1st weekday heating period time and temperature Each ti
16. temperature limitation 4 04 CC CIF Select temperature display to C or F 5 05 FA FA SL Select fast heating or slow heating 6 06 00 PP OO Select pump protection PP Cancel pump protection OO 7 07 24 12 or 24 Selection of time scale 8 08 7 0 3 7 Programming day in one week option 9 09 P6 P4 P6 Programming period per day option 10 Press button revert to the program operation 1 Select temperature recalibrates Adjustment 3 LO to 3 HI You can adjust the room temperature display up to 3 higher or lower Your thermostat was accurately calibrated at the factory but you have the option to change the display temperature to match your previous thermostat The current or adjusted room temperature will be displayed on the right side of the display 2 Select maximum temperature set point This feature provides a maximum set point temperature f The default setting is 35C 95 F It can be changed between 18 C 64 F to 35 C 95 F 3 Select minimum temperature set point This feature provides a minimum set point temperature The default setting is SC 41 F It can be changed between 5 C 41F to20C 68 F 4 Select F or C readout Changes the display readout to Centigrade or Fahrenheit as required 5 Select fast heating or slow heating Select FA to start heating immediately when the set point is 1 C above the room temperature Select SL to start heating only when the set point is 3 C above the
17. under running water nor submerse in water Do not use harsh abrasive or easily inflammable detergents Disposal The infrared heating element has to be disposed separately from general household waste at municipal refuse service provided for this purpose Y You can obtain detailed information for disposal from your local authority Funkyheat Appendix Funkyheat Funkyheaf SMART EFFICIENT HEATING Sold amp Distributed in the UK amp Ireland by Funkyheat Ltd The Carlile Institute Huddersfield Road Meltham HD9 4AE www funkyheat co uk Funkeat COMFORT HEATING CC908 RF3 Wireless temperature controller CC908 RF3 can replace most common residential thermostat and is designed to be used with electric gas or oil heating control system Unlike ordinary single unit design thermostat this unit is a new type of thermostat separating the thermostat function into two units Receiver CC2010DE and Control Centre CC908 DF1 The Receiver serves for wiring connections and heat on off control The Control Centre serves as user interface and temperature sensing control User can put the control Centre nearby and can read control the temperature of really the living area while put the Receiver besides the heating system SPECIFICATION O Power source cece cece eee eee Control Centre 2 AA batteries Receiver 220VAC 10 50 60HZ e Frequency band 00 eee 868MHZ Relay contact cee 16
18. wired at all times during operation e The minimum distance to other objects should be 50cm from the front 20cm to the sides and 10cm upward and downward e For the installation of an infrared heater on a brick or stone wall only the holding and fixing material provided should be used On other types of wall or masonry e g plasterboard wood please use suitable holding and fixing material e In case of possible disassembly or transport allow the infrared heater to completely cool down before attempting to move e The infrared heater is not meant to be handled by persons children included with reduced physical sensorial or mental faculties or without Funkyheat experience and or knowledge unless they are supervised by a person responsible for their safety or receive instructions on how to use the device Children never see danger which can occur when dealing with electrical devices So never leave children alone with electrical devices Keep out of reach of small children If the device is installed in children s rooms or rooms accessible to children make sure that the device is suspended at a minimum of 1 2m above the ground Do not try to repair the infrared heater the power cable cannot be replaced and must always be returned to the manufacturer for repairs Funkyheat Installation Read these safety instructions and manual before use Check the infrared heater for visible damage and whether the main voltage is in
Download Pdf Manuals
Related Search
Related Contents
De'Longhi DESFGG36 User's Manual MANUAL DE BOAS PRÁTICAS CC 1022 KHI P.V.P OPERATIONS, SERVICE MANUAL & PARTS LIST SimFlex™ Client Simulator – User Manual © 2011 Copyright © All rights reserved.
Failed to retrieve file