Home

Professional G Developers Tools Reference Manual

image

Contents

1. 2 4 Code and Fix Model 2 4 Waterfall Model 2 5 Modified Waterfall Model 2 7 Prototyping 2 7 G Prototyping Methods 2 8 Spiral Model 2 9 Summary 2 11 Contents Professional G Developers Tools Reference Manual vi National Instruments Corporation Chapter 3 Incorporating Quality into the Development Process Quality Requirements 3 1 Configuration Management 3 2 Source Code Control 3 2 Managing All Project Related Files
2. 8 4 Globals Locals Statistics 8 4 CINs Shared Library Statistics 8 4 SubVI Interface Statistics 8 5 Files in vi lib 8 5 Saving Metric Information 8 5 Contents National Instruments Corporation ix Professional G Developers Tools Reference Manual Chapter 9 Documentation Tool Chapter 10 VI Comparison Tools Compare Hierarchies 10 1 Comparison Options 10 3 Show Differences 10 3 Compare VIs 10 5 Comparison Issues 10 6 Source Code Control Compare Files
3. 11 18 Figure 11 7 Edit Project File List Dialog Box 11 19 Figure 11 8 Edit Extra Files Dialog Box 11 22 Figure 11 9 Edit Project Group Dialog Box 11 23 Figure 11 10 SCC Retrieve Files Dialog Box 11 24 Figure 11 11 SCC File Properties Dialog Box 11 25 Figure 11 12 SCC Check Files Out Dialog Box 11 26 Figure 11 13 SCC Check Files In Dialog Box 11 28 Figure 11 14 Edit Change Comments Dialog Box 11 29 Figure 11 15 SCC Advanced Dialog Box 11 30 Figure 11 16 SCC Reports Dialog Box for Built in SCC System 11 35 Figure 11 17 SCC Edit File Platforms Dialog Box 11 38 Tables Table 2 1 Risk Exposure Analysis Example 2 10 Table 7 1 Examples of Font Styles and When to Use Each 7 5 National Inst
4. xiii Part I Software Engineering Concepts xiii Part II Professional Development Tools xiv Appendices Glossary and Index xiv Conventions Used in This Manual xiv Related Documentation xv Customer Communication xvi Chapter 1 Introduction Required System Configuration 1 1 Configuration 1 1 Overview 1 2 Features of the Tools 1 2 PART I Software Engineering Concepts Chapter 2 Development Models Common Development Pitfalls 2 1 Lifecycle Models
5. 10 7 Chapter 11 Source Code Control Tools General Source Code Control Concepts 11 1 Using Individual Files Instead of VI Libraries 11 2 QuickStart Guide to Using the SCC Tools 11 2 Selecting the Source Code Control System 11 4 Built In System 11 5 Third Party SCC Systems 11 6 Administrator Setup 11 7 Configuring the SCC System 11 7 Built In System 11 8 Visual SourceSafe 11 9 ClearCase 11 10 Optional Administrator Setup 11 12 Edit Platform List Advanced Option
6. 7 5 Color 7 5 Graphics and Custom Controls 7 6 Front Panel Layout 7 7 Sizing and Positioning Front Panels 7 7 Controls and Indicators 7 8 Descriptions 7 8 Labels 7 8 Enumerations versus Rings 7 9 Default Values Ranges and Coercion 7 10 Attribute Nodes 7 11 Contents Professional G Developers Tools Reference Manual viii National Instruments Corporation Key Navigation 7 11 Local Variables
7. 8 3 Figure 9 1 Documentation Tool Dialog Box 9 1 Figure 10 1 Compare VI Hierarchies 10 2 Figure 10 2 Differences Window 10 3 Figure 10 3 Block Diagram Difference 10 4 Figure 10 4 Compare VIs Dialog Box 10 5 Figure 10 5 Comparison Progress Dialog Box 10 6 Figure 10 6 SCC Compare Files Dialog Box 10 7 Figure 11 1 G SCC Tools Can Work with Built In and Third Party Systems 11 5 Figure 11 2 SCC Administration Dialog Box 11 7 Figure 11 3 Administer Builtin System Dialog Box 11 8 Figure 11 4 SCC Edit Platform List Dialog Box 11 13 Contents Professional G Developers Tools Reference Manual xii National Instruments Corporation Figure 11 5 SCC Local Configuration Dialog Box 11 14 Figure 11 6 SCC Project Dialog Box
8. 7 12 VI Setup 7 13 Connector Panes 7 14 Icons 7 15 The Block Diagram 7 16 Wiring Etiquette 7 17 Labeling 7 18 Execution Sequence 7 18 Left to Right Layouts 7 18 Data Dependency 7 19 Adding Common Threads 7 19 Sequence Structures 7 20 Watch Out for Missing Dependencies 7 20 Check for Errors
9. 11 37 Platform Specific Files 11 38 Variants of a File for Different Platforms 11 39 Retrieving Files for a Different Platform 11 39 Appendix A References Appendix B Customer Communication Glossary Index Contents National Instruments Corporation xi Professional G Developers Tools Reference Manual Figures Figure 2 1 Waterfall Lifecycle Model 2 5 Figure 2 2 Spiral Lifecycle Model 2 9 Figure 3 1 Capability Maturity Model 3 15 Figure 4 1 Flowchart of a Data Acquisition System 4 4 Figure 4 2 Mapping Pseudocode into a G Data Structure 4 5 Figure 4 3 Mapping Pseudocode into Actual G Code 4 5 Figure 4 4 Data Flow for a Generic Data Acquisition Program 4 6 Figure 4 5 VI Hierarchy for the Tektronix 370A 4 8 Figure 4 6 Operations Run Independently 4 11 Figure 4 7 Loop Performs O
10. 11 21 Contents Professional G Developers Tools Reference Manual x National Instruments Corporation Removing Files from a Project 11 21 Adding Extra Files to a Project 11 21 Project Groups 11 22 Accessing Files 11 23 Retrieving Files 11 23 File Status 11 24 File Properties 11 25 Checking Out Files 11 26 Use the History Window to Document Changes 11 27 Checking In Files 11 28 SCC User Name 11 29 Advanced Features 11 30 Del
11. 7 21 Sizing and Positioning of Block Diagrams 7 23 Optimization 7 24 Code Interface Nodes 7 25 CIN Description Contents 7 25 CIN Source Code 7 25 Style Checklist 7 26 VI Checklist 7 26 Front Panel Checklist 7 27 Block Diagram Checklist 7 28 PART II Professional Development Tools Chapter 8 VI Metrics Tool Using the VI Metrics Tool 8 2 Additional Statistics 8 3 Block Diagram Statistics 8 3 User Interface Statistics
12. 3 3 Retrieving Old Versions of Files 3 3 Tracking Changes 3 4 Change Control 3 4 Testing Guidelines 3 5 Black Box and White Box Testing 3 6 Unit Integration and System Testing 3 6 Unit Testing 3 7 Integration Testing 3 8 System Testing 3 9 Formal Methods of Verification 3 9 Style Guidelines 3 10 Design Reviews 3 11 Code Walkthroughs 3 11 Post Mor
13. or Consequently you might have to rename some files and update references within your hierarchy If you need to support Windows 3 1 refer to the Cross Platform Source Code Control section later in this chapter for suggestions on the best strategy for handling development 4 Users create SCC projects A project in the SCC tools corresponds to a hierarchy of VIs To create a project first open the top level VI of a hierarchy Then select Project Source Code Control Project and click the New Project button The SCC Edit Project File List dialog box lets you select your VI hierarchy which can then be added to SCC As mentioned previously all files that you want to add to SCC must be in your working directory or one of its subdirectories They cannot be in LLBs You can add other project related files such as documentation and shared libraries by using the Extra Files button in this dialog box 5 Users use SCC commands to access project files At this point you can begin to work with files under SCC All commands related to SCC are in the Project Source Code Control menu Following is a brief description of the remaining commands Check Files In Use to copy a file from your working directory to SCC so that other users can access it Check Files Out Use to check out files to your working directory so that you can modify them Compare Files Use to compare the files in your working directo
14. National Instruments Corporation 2 7 Professional G Developers Tools Reference Manual customers Many people also think the amount of documentation is excessive and inflexible Although the waterfall model has its weaknesses it is instructive because it emphasizes important stages of project development Even if you do not apply this model you should consider each of these stages and its relationship to your own project Modified Waterfall Model Many engineers recommend modified versions of the waterfall lifecycle These modifications tend to focus on allowing some of the stages to overlap reducing the documentation requirements and reducing the cost of returning to earlier stages to revise them Another common modification is to incorporate prototyping into the requirements phases as described in the following section Overlapping stages such as requirements and design make it possible to feed information from the design phase back into the requirements However this can make it more difficult to know when you are finished with a given stage Consequently it is more difficult to track progress Without distinct stages problems might cause you to defer important decisions until late in the process when they are more expensive to correct Prototyping One of the main problems with the waterfall model is that the requirements often are not completely understood in the early development stages When you reach the design or codin
15. Unit Integration and System Testing Black box and white box testing can be used to test any component of software regardless of whether it is an individual VI or the complete application Unit integration and system testing are phases of your project at which you can apply black box and white box tests Chapter 3 Incorporating Quality into the Development Process National Instruments Corporation 3 7 Professional G Developers Tools Reference Manual Unit Testing You can use unit testing to concentrate on testing individual software components For example you might test an individual VI to see that it works correctly deals with out of range data has acceptable performance and that all major execution paths in its block diagram are executed and performed correctly Individual developers can perform unit tests as they work on their modules Some examples of common problems unit tests might account for include the following Boundary conditions for each input such as empty arrays and empty strings or 0 for a size input Be sure floating point parameters deal with infinity and not a number Invalid values for each input such as 3 for a size input Strange combinations of inputs Missing files and bad pathnames What happens when the user clicks the Cancel button in a file dialog box What happens if the user aborts the VI Define various sets of inputs that thoroughly test you
16. 11 13 Local Configuration 11 14 Configuring the SCC System 11 14 Built In System 11 15 Visual SourceSafe 11 15 ClearCase 11 15 Local Work Directory 11 16 Platform Drop Down Menu 11 17 Managing Source Code Control Projects 11 17 Source Code Control Projects Overview 11 17 Managing Multiple Hierarchies 11 17 Creating a Project 11 18 Updating a Project 11 20 SCC File Wizard 11 20 Managing Files with the Same Name
17. Compares the local versions of files with the versions under Source Code Control Compare Hierarchies You can use the Compare Hierarchies command to compare two hierarchies of VIs Any file with the same name in both hierarchies is compared After the comparison completes Compare Hierarchies displays a summary of the differences You can select a set of VIs that have differences and visually compare them using the Compare VIs tool Chapter 10 VI Comparison Tools Professional G Developers Tools Reference Manual 10 2 National Instruments Corporation To compare two VI hierarchies select Project Compare VI Hierarchies Use the Compare VI Hierarchies dialog box shown in Figure 10 1 to select two hierarchies to compare Figure 10 1 Compare VI Hierarchies Select two VI hierarchies to compare by entering the path to the top level VI Use the button to open a file dialog box to select a VI from the file system You then can use the Compare Hierarchies button to compare VIs in the hierarchies VIs with the same name but different paths are compared and categorized as being the same or different VIs with the same name and path are considered shared VIs All other VIs are categorized as added or deleted from the first VI hierarchy The VIs in Hierarchies listbox displays the VIs and a symbol that indicates how they are categorized As you select different VIs in the listbox a more detailed description appears in the Description
18. Index Professional G Developers Tools Reference Manual I 2 National Instruments Corporation Compare VIs command 10 5 to 10 6 Compare VIs dialog box 10 5 Comparison Progress dialog box 10 6 renaming VIs for comparison 10 6 configuration management 3 2 to 3 5 change control 3 4 to 3 5 definition 3 2 managing project related files 3 3 retrieving old versions of files 3 3 to 3 4 source code control 3 2 to 3 3 tracking changes 3 4 configuration of SCC tools See Source Code Control tools connector panes style considerations 7 14 to 7 15 consistency of style See style guidelines Constructive Cost Model COCOMO estimation 5 6 control descriptions as documentation 6 6 controls and indicators default values ranges and coercion 7 10 to 7 11 indicator descriptions as documentation 6 6 local variables for consistent values 7 12 to 7 13 style considerations 7 8 to 7 13 attribute nodes 7 11 default values ranges and coercion 7 10 to 7 11 descriptions 7 8 enumerations vs rings 7 9 key navigation 7 11 to 7 12 labels 7 8 to 7 9 local variables 7 12 to 7 13 text styles 7 5 cross platform considerations See multiplatform considerations custom controls and graphics 7 6 to 7 7 customer communication xvi B 1 to B 2 D data dependency 7 19 missing dependencies 7 20 to 7 21 default values for controls 7 10 to 7 11 design reviews 3 11 See also code walkthroughs design techniques 4 1 to 4 9
19. Many people favor them because it is a relatively easy metric to gather and because a lot of literature has been written about it Detractors of size metrics point out the following flaws Size based metrics are dependent on the organization Lines of code numbers of nodes can be useful within an organization as long as you are dealing with the same group of people and they are following the same style guidelines Trying to use size metrics from other companies groups can be difficult because of differing levels of experience different expectations for testing and development methodologies and so on Size based metrics are also dependent on the programming language Comparing a line of code in assembly language to one written in C can be like comparing apples to oranges Statements in higher level Chapter 5 Scheduling and Project Tracking Professional G Developers Tools Reference Manual 5 4 National Instruments Corporation languages can provide more functionality than those in lower level languages Comparing numbers of nodes in G to lines of code in a textual language can be inexact for this reason Not all code is created with the same level of quality A VI that retrieves information from a user and writes it to a file can be written so efficiently that it involves a small number of nodes or it can be written poorly with a large number of nodes Not all code is equal in complexity An add function is much e
20. Place large scrollable text items off to the side of the block diagram to avoid cluttering the screen When a VI is loaded on a different platform the fonts change Front panel labels might move automatically if they overlap controls Block diagram elements however do not move to accommodate font changes Place labels below objects to ensure they stay next to the object even if they grow or shrink on the bottom and right sides Right justify any labels you place to the left of an object Execution Sequence The following sections describe programming concepts that will help you take advantage of the natural data flow in block diagrams Left to Right Layouts G was designed to use a left to right and sometimes top to bottom layout Your block diagrams should follow this convention While the positions of program elements do not determine execution order avoid wiring from right to left Only data connections or wires and structures determine execution order Chapter 7 Using Consistent Style The G Style Guide National Instruments Corporation 7 19 Professional G Developers Tools Reference Manual Data Dependency As described in Chapter 19 Structures in the G Programming Reference Manual artificial data dependency should be applied wherever practical If a section of the block diagram is missing the appropriate inputs or outputs you might use a single frame Sequence Structure Do not overdo it though To impose a pure dat
21. Professional G Developers Tools Reference Manual 7 26 National Instruments Corporation Style Checklist Use the following checklist to help you maintain consistent style and quality You might want to copy this checklist to use on all your projects VI Checklist K Organize VIs in a hierarchical directory with easily accessible top level VIs and subVIs in subdirectories K Avoid putting too many VIs in one library because large LLBs take longer to save K With LLBs use File Edit VI Library to mark top level VIs K If the VIs will be used as subVIs use Edit Edit Control amp Function Palettes to create a mnu file or edit the menu that is part of the LLB Be sure to do the following Arrange palettes Name menus Hide dependent subVIs K Give VI meaningful names without special characters such as backslash slash colon and tilde K Use standard extensions so Windows and UNIX can distinguish files vi ctl K Capitalize initial letters of VI names K Distinguish example VIs top level VIs subVIs controls and global variables by saving them in subdirectories separate libraries in the same directory or by giving them descriptive names such as MainX vi Example of X vi Global X vi and TypeDef X ctl K Write a VI description Proofread it Check the Help window K Include your name and or company and the date in the VI description K When you modify a V
22. excluding comments and blank lines The VI Metrics tool described in Chapter 8 VI Metrics Tool provides a method for measuring a corresponding metric for G based code The VI Metrics tool counts the number of nodes used within a VI or within a hierarchy of VIs A node is almost any object on a block diagram excluding labels and graphics but including functions VIs and structures such as loops and sequences Refer to Chapter 8 VI Metrics Tool for more information on how to use this tool and the accounting mechanism it uses You can use number of nodes as a method for estimating future project development efforts For this to work you must build a base of knowledge about current and previous projects You must have an idea of the amount of time it took to develop components of existing software products and associate that information with the number of nodes used in that component Armed with this historical information you next need to estimate the number of nodes required for a new project It is not possible to do this for an entire project at once Instead you must break the project down into subprojects you can compare to other tasks completed in the past Once you have broken it down you can estimate each component and produce a total estimate of the number of nodes and the time required for development Problems with Source Lines of Code and Number of Nodes Size based metrics are not uniformly accepted in software engineering
23. gt and Paths are limited to 255 characters including the filename Windows NT supports FAT and NTFS file systems FAT filename restrictions are the same for Windows 95 NTFS filenames are limited to 255 characters in length and have the same character limitations as FAT NTFS paths are not limited in length Consequently for maximum portability you should avoid using lt gt and in filenames and limit filenames to 31 characters or less Also because of the path length restrictions under the FAT file system of Windows 95 NT you should avoid paths that are deeply nested longer than 255 characters The File Manager tool can scan a set of directories or VI libraries for invalid names Platform Dependent SCC Files LabVIEW and BridgeVIEW are available for a variety of computing platforms You can open most VIs on any platform LabVIEW and BridgeVIEW support and they will run without modification You can use the G SCC tools to share code among developers on any platform where LabVIEW or BridgeVIEW is available In most cases you will probably want all files in Source Code Control to be available for all platforms In some cases you might have files in your system that are platform specific The following are cases that might involve platform specific issues VIs that take advantage of platform specific features such as DDE can be taken to a platform that does not support the feature but the VI will
24. Additional Statistics In addition to measuring the number of nodes the VI Metrics tool measures a number of other statistics related to the complexity of your VI s To show the additional information turn on the appropriate category checkbox at the top right of the VI Metrics dialog box Block Diagram Statistics Structures Number of For Loops While Loops Case Structures and Sequence Structures Diagrams Number of block diagrams Each VI has a single top level block diagram In addition it has one subdiagram for each loop and for each frame of a sequence or case Chapter 8 VI Metrics Tool Professional G Developers Tools Reference Manual 8 4 National Instruments Corporation Maximum diagram depth Deepest nesting level of block diagrams in a VI If your VI has no structures such as cases loops and sequences it has a depth of 0 Diagram width Width of the block diagram in pixels Diagram height Height of the block diagram in pixels Wire sources Wire sources measures the total number of sources in your VI Each wire has a single source but it can branch to multiple destinations If however a wire crosses from one block diagram to another through a tunnel the tunnel is considered to be a new source User Interface Statistics Controls Number of top level controls on a VI front panel A cluster or an array is counted as a single control Indicators Number
25. Also you can incorporate prototyping into any stage from the architectural design and after Refer to the Prototyping section later in this chapter for more information The waterfall lifecycle model is one of the oldest models and is widely used in government projects and in many major companies Because it emphasizes planning in the early stages it helps catch design flaws before they are developed Also because it is document and planning intensive it works well for projects in which quality control is a major concern Many people believe you should not apply this model to all situations For example with the pure waterfall model you must state the requirements before you begin the design and you must state the complete design before you begin coding There is no overlap between stages In real world development however you might discover issues during the design or coding stages that point out errors or gaps in the requirements The waterfall method does not prohibit returning to an earlier phase for example from the design phase to the requirements phase However this involves costly rework Each completed phase requires formal review and extensive documentation development Thus oversights made in the requirements phase are expensive to correct later Because the actual development comes late in the process you do not see results for a long time This can be disconcerting to management and to Chapter 2 Development Models
26. Data type Valid range for inputs Default value for inputs Behavior for special values 0 empty array empty string and so on Additional information such as whether the user must set this value always often or rarely Alternatively you can list the default value in parentheses as part of the VI name For controls and indicators on the VI connector pane mark the inputs and outputs as Required Recommended or Optional Refer to the Connector Panes section in Chapter 7 Using Consistent Style The G Style Guide for more information National Instruments Corporation 7 1 Professional G Developers Tools Reference Manual 7 Using Consistent Style The G Style Guide This chapter describes recommended practices for good programming technique and style Remember that these are only recommendations not laws or strict rules Consider your audience Users need a good front panel developers need a good block diagram and everybody needs good documentation Several experienced G programmers have contributed to this guide As mentioned in Chapter 3 Incorporating Quality into the Development Process inconsistent style causes problems when multiple developers are working on the same project The resulting VIs can confuse users and be difficult to maintain To avoid these problems establish a set of style guidelines for VI development You can establish an initial set at the beginning of the project and add
27. LabVIEW natinst com and National Instruments are trademarks of National Instruments Corporation Product and company names listed are trademarks or trade names of their respective companies WARNING REGARDING MEDICAL AND CLINICAL USE OF NATIONAL INSTRUMENTS PRODUCTS National Instruments products are not designed with components and testing intended to ensure a level of reliability suitable for use in treatment and diagnosis of humans Applications of National Instruments products involving medical or clinical treatment can create a potential for accidental injury caused by product failure or by errors on the part of the user or application designer Any use or application of National Instruments products for or involving medical or clinical treatment must be performed by properly trained and qualified medical personnel and all traditional medical safeguards equipment and procedures that are appropriate in the particular situation to prevent serious injury or death should always continue to be used when National Instruments products are being used National Instruments products are NOT intended to be a substitute for any form of established process procedure or equipment used to monitor or safeguard human health and safety in medical or clinical treatment National Instruments Corporation v Professional G Developers Tools Reference Manual Contents About This Manual Organization of This Manual
28. Software Engineering Concepts This section of the manual describes software engineering concepts Chapter 2 Development Models provides examples of some common development pitfalls and describes a number of software engineering lifecycle models Chapter 3 Incorporating Quality into the Development Process describes strategies for producing quality software Chapter 4 Prototyping and Design Techniques gives you pointers for project design including programming approaches prototyping and benchmarking Chapter 5 Scheduling and Project Tracking describes techniques for estimating development time and using those estimates to create schedules Chapter 6 Creating Documentation describes techniques for documenting your software Chapter 7 Using Consistent Style The G Style Guide describes recommended practices for good programming technique and style National Instruments Corporation 2 1 Professional G Developers Tools Reference Manual 2 Development Models This chapter provides examples of some common development pitfalls and describes a number of software engineering lifecycle models G the graphical programming language of LabVIEW and BridgeVIEW makes it easy to assemble components of data acquisition test and control systems Because it is so easy to program in G you might be tempted to begin developing VIs immediately with relatively little planning For simple application
29. The built in system manages files by copying them to and from a shared network directory that all users in a development group can access It has many of the capabilities of full featured Source Code Control systems including access to previous versions of files history information maintenance and labeling files for easy retrieval The built in system has some advantages over using third party systems including the following It is available for all platforms except Windows 3 1 Most third party tools work only for a single operating system Most third party tools have additional licensing costs ClearCase for Solaris 2 Visual SourceSafe for Windows 95 NT Built In SCC System G Source Code Control Tools Chapter 11 Source Code Control Tools Professional G Developers Tools Reference Manual 11 6 National Instruments Corporation However there are some disadvantages to the built in system compared to a third party system including the following The built in system does not provide as much security as most third party systems You can control access somewhat by using file system permissions but you do not have the same level of control as with a more powerful SCC system The built in system does not use compression for files on the server Some third party systems can store files on the server and differences between versions or deltas in a compressed format However because VIs are binary files
30. and a brief summary of the changes Visual SourceSafe With Visual SourceSafe you can generate the file listings from the SCC Reports dialog box You have to generate transaction listings and other reports from the Visual SourceSafe environment Remember that the Chapter 11 Source Code Control Tools Professional G Developers Tools Reference Manual 11 36 National Instruments Corporation system history can be viewed by looking at the history of the sccfiles lst file Refer to the System History section earlier in this chapter for more information Multiplatform Issues This section describes multiplatform issues such as cross platform SCC filename limitations and platform dependent SCC files Cross Platform Source Code Control Unlike most Source Code Control tools the built in SCC system lets you access files from all the platforms LabVIEW and BridgeVIEW support except Windows 3 1 Refer to the Using Individual Files Instead of VI Libraries section earlier in this chapter for more information Windows 3 1 is not supported because the SCC tools manage VIs as individual files and the Windows 3 1 8 3 character naming limitation makes this impractical While LLBs make it possible to use longer names they do not provide the level of transparent access to files that is needed for the built in SCC tools Although you cannot use the SCC tools on Windows 3 1 National Instruments understands that customers need Windows 3 1 support
31. and extra files associated with the project Some development efforts you work on might have more than one top level VI For example if your VI uses the VI Control VIs to dynamically load and call VIs the dynamically called subVIs are not considered a part of your hierarchy In this case create separate projects for each dynamically called VI Chapter 11 Source Code Control Tools National Instruments Corporation 11 23 Professional G Developers Tools Reference Manual An SCC project group is a collection of projects You can use project groups to make it more convenient to retrieve and manipulate files from multiple projects To create a project group first define the individual projects you want the project group to contain Select Project Source Code Control Project and click the New Project Group button in the SCC Project dialog box to display the SCC Edit Project Group dialog box as shown in Figure 11 9 Figure 11 9 Edit Project Group Dialog Box The SCC Edit Project Group dialog box lets you enter a name for the group and select the projects for the group to contain Project groups can contain any number of projects and can contain references to other project groups Once you create a project group its name shows up as a project you can select when you use the SCC Check Files Out SCC Check Files In SCC Retrieve Files or SCC Advanced dialog boxes Accessing Files The following sections show you how to retri
32. behind you could sacrifice planned features or add time to the overall schedule If you do not realize you are behind schedule until the fifth month other groups might have made decisions that are costly to change When you realize you are behind adjust the schedule or consider features you can drop or postpone to subsequent releases Do not ignore the delay or sacrifice testing scheduled for later in the process Refer to Chapter 5 Scheduling and Project Tracking for more information on estimating project schedules Numerous other problems can arise when developing software The following list includes some of the fundamental elements of developing quality software on time Spend sufficient time planning Make sure the whole team thoroughly understands the problems that must be solved Have a flexible development strategy that minimizes risk and accommodates changes Chapter 2 Development Models Professional G Developers Tools Reference Manual 2 4 National Instruments Corporation Lifecycle Models Software development projects are complex To deal with these complexities developers have collected a core set of development principles These principles define the field of software engineering A major component of this field is the lifecycle model The lifecycle model describes the steps you follow to develop software from the initial concept stage to the release maintenance and subsequent upgrading of
33. most Source Code Control systems do not handle deltas for VIs efficiently Third Party SCC Systems In addition to the advantages and disadvantages described in the previous section there are some additional points to notice when considering a third party SCC system Although you can use a third party SCC system you might not be able to take advantage of all the features that tool offers For instance the G SCC tools do not support a feature called branching where different projects use different versions of a VI If you want to branch development you need to make a copy of the VIs you want to change If you already have VIs stored under an existing SCC the G SCC tools will not be aware of them You will need to create projects for the files using the G SCC tools With Visual SourceSafe the G SCC tools have to keep track of the modification date and check out status for files internally Consequently you should not modify VI files or check them out from the SourceSafe Explorer because the G SCC tools will get out of sync with the state of the files Instead if you need to perform any operation that modifies a VI file in the SourceSafe database you need to do that modification using the SCC tools in LabVIEW or BridgeVIEW Chapter 11 Source Code Control Tools National Instruments Corporation 11 7 Professional G Developers Tools Reference Manual Administrator Setup The administrator has an extra menu option Project Sourc
34. the default text for this entry is the VI history text since you checked out the file However you are given a chance to change this entry so the SCC history entry is more detailed or more succinct This SCC file history information is maintained within the SCC system and does not become a part of the VI Chapter 11 Source Code Control Tools Professional G Developers Tools Reference Manual 11 32 National Instruments Corporation The SCC View File History dialog box appearance depends on the Source Code Control system you use either the built in system or a third party source code system At a minimum it lets you scroll through a listing of information about each file In addition most systems should allow you to access previous versions of files Refer to the Accessing Previous Versions of Files section later in this chapter for more information Also the built in system and some third party systems such as Visual SourceSafe and ClearCase for Solaris 2 gives you the option to label the current version of a file so it is easier to recognize if you later want to retrieve it For example you might label a file as beta so you can easily retrieve that checkpoint version later Refer to the Labeling Versions of Files for Easy Retrieval section later in this chapter for more information It is important that you enter detailed comments when you check in files and if you use the History window because that information can help you understan
35. 7 10 to 7 11 Rational Software ClearCase for Solaris 2 See ClearCase for Solaris 2 references A 1 to A 2 report generation with SCC tools 6 2 11 34 to 11 36 required system configuration 1 1 Rich Text Format RTF file for documentation 9 2 rings vs enumerations 7 9 risk management See spiral model RTF file for documentation 9 2 S safeguarding applications 3 1 to 3 2 See also quality control SCC See Source Code Control tools scheduling and project tracking 5 1 to 5 8 See also project management SCC tools VI Metrics tool estimation 5 1 to 5 6 COCOMO estimation 5 6 effort estimation 5 4 function point estimation 5 6 lines of code number of nodes 5 2 to 5 3 problems with size based metrics 5 3 to 5 4 wideband Delphi estimation 5 5 mapping estimates to schedules 5 6 to 5 7 Index National Instruments Corporation I 7 Professional G Developers Tools Reference Manual tracking schedules using milestones 5 7 to 5 8 missed milestones 5 8 Sequence Structures 7 20 size based metrics See also VI Metrics tool lines of codes 5 2 to 5 3 number of nodes 5 3 problems 5 3 to 5 4 SLOCs See Source Lines of Code SLOCs metric software quality standards 3 13 to 3 17 CMM 3 15 to 3 16 FDA standards 3 14 IEEE 3 16 to 3 17 ISO 9000 3 13 to 3 14 Source Code Control tools accessing files 11 23 to 11 30 change control 3 4 to 3 5 checking in files 11 28 to 11 29 checking out files 11 26 to
36. As a developer you might need to deploy applications to customers that are using systems with Windows 3 1 In that case develop your application under Windows 95 NT On those platforms you can use individual files for VIs When you are ready to distribute to Windows 3 1 users you can save copies of your VIs into LLBs An easy way to convert your files to or from LLBs is to use the File Manager tool which allows you to convert between directories and LLBs Once the administrator has set up the Source Code Control system you can access it from any supported platform There are some issues you should be aware of if you are developing VIs on or for multiple platforms including filename limitations and platform dependent SCC files Filename Limitations Macintosh Windows 95 NT and UNIX systems each have restrictions about filenames and paths you need to be cautious about if you plan to support multiplatform development Macintosh filenames are limited to 31 characters in length and cannot contain the character Paths are not limited in length Chapter 11 Source Code Control Tools National Instruments Corporation 11 37 Professional G Developers Tools Reference Manual UNIX filenames are limited to 255 characters in length and cannot contain the character Paths are not limited in length Windows 95 filenames are limited to 255 characters in length and cannot contain the following characters lt
37. Chapter 4 Prototyping and Design Techniques Professional G Developers Tools Reference Manual 4 2 National Instruments Corporation Another example of overly constraining a design is to be too specific about the format for display used in various screens with which the customer interacts A picture of a display might be useful to explain requirements but be clear about whether the picture is a requirement or a guideline Some designers go through significant difficulties trying to produce a system that behaves in a specific way because a certain behavior was a requirement In this case there might be a simpler solution that produces the same results at a much lower cost in a shorter time Top Down Design The block diagram programming metaphor G uses was designed to be easy to understand Most engineers already use block diagrams to describe systems The goal of the block diagram is to make it easier for you to move from the system block diagrams you create to executable code The basic concept is to divide the task into manageable pieces at logical places Begin with a high level block diagram that describes the main components of your system For example you might have a block diagram that consists of a block for configuration a block for acquisition a block for analysis of the acquired data a block for saving the data to disk and a block to clean up at the end of the system After you determine the high level blocks create a blo
38. Corporation 12 Set VOB directory e g vobs vobname 13 Click OK in the ClearCase Configuration dialog box 14 Click OK in the SCC Administration dialog box Optional Administrator Setup You must complete these steps if you want to add VIs to ClearCase 1 Complete local configuration Refer to the ClearCase section later in this chapter for more information 2 Set your umask to 2 to give other users in your group access to any new directories you create 3 Set a view and launch LabVIEW or BridgeVIEW 4 Copy files to the VOB directory Use Project File Manager or copy them using UNIX commands The File Manager tool is useful because it can convert LLBs to VIs LLBs are not supported by the SCC tools 5 Open the top level VI for a new project 6 Create a new project using Project Source Code Control Project 7 Click the New Project button 8 Select the top level VI from the pop up menu near the top of the dialog box It will automatically assign a name for the project You can change the assigned name Click Save 9 The VI hierarchy and its subVIs are now in Source Code Control Repeat this process for additional hierarchies Chapter 11 Source Code Control Tools National Instruments Corporation 11 13 Professional G Developers Tools Reference Manual Edit Platform List Advanced Option Clicking the Edit Platform List button in the SCC Administration dialog box displays th
39. Professional G Developers Tools Reference Manual Compare VIs When developing applications you might have multiple versions of the same VIs The Compare VIs feature also called Graphical Differencing helps you track changes in your application by comparing multiple versions of a VI This becomes especially important as your project grows and involves more developers You can use the Project Compare VIs command to graphically compare two VIs You can select options to control the types of differences you want to detect and view For example you can filter out cosmetic changes such as objects being moved or resized When you compare the VIs a dialog displays a summary of the differences If you select an item from the summary Compare VIs displays and highlights the differences between the two VIs To compare two VIs select Project Compare VIs Use the Compare VIs dialog box to select two VIs to compare as shown in Figure 10 4 Figure 10 4 Compare VIs Dialog Box The Select button opens a dialog box to select a VI by name You can select only VIs that are already loaded into memory Chapter 10 VI Comparison Tools Professional G Developers Tools Reference Manual 10 6 National Instruments Corporation Comparing very large VIs can be lengthy You can cancel the comparison of two VIs through the Comparison Progress dialog box shown in Figure 10 5 Figure 10 5 Comparison Progress Dialog Box The progress bar indi
40. Source Code Control Project Select the project in the SCC Project dialog box and click the Edit Project button Select the file s in the SCC Edit Project File List dialog box and click the Remove button or double click the file When you remove VIs from a project they remain listed in the project file list but they have an X next to them to indicate that they have been removed You can add the files back to the project by double clicking on the file A checkmark appears next to the file Another way to remove files from the project is to use the Exclude Directories dialog box and select the directory that contains the files you want to exclude You can access the Exclude Directories dialog box by clicking the Exclude Dirs button in the SCC Edit Project File List dialog box Files you exclude in this fashion are dimmed in the project file list Notice that when you remove a file from a project it is not removed from Source Code Control One reason for this is that multiple projects can share files Also even files that are not part of a project are retained in SCC because they might be important for historical reasons To permanently delete a file select Project Source Code Control Advanced Select the file you want to delete and click the Delete File button in the SCC Advanced dialog box Adding Extra Files to a Project In many cases the work you develop consists of more than just VIs You probably have specificati
41. Source Code Control they are locked to prevent accidental modification When you want to modify a file that is under SCC you must check out the file Refer to the Checking Out Files section later in this chapter for more information The files in your hierarchy must be present in your working directory or in an LLB before you can add those files to Source Code Control You can add files that are not part of your hierarchy to the project by clicking the Extra Files button You can add project related documents such as proposals specifications and illustrations to SCC You also can add support files such as shared libraries DLLs and external subroutines lsb files that are not detected normally as part of your VI hierarchy but are necessary to run your software Refer to the Adding Extra Files to a Project section later in this chapter for more information The Platforms and Exclude Dirs buttons are advanced options you typically do not need to modify The Platforms button lets you work with platform specific files If your application calls Code Interface Nodes CINs or DLLs you might have Chapter 11 Source Code Control Tools Professional G Developers Tools Reference Manual 11 20 National Instruments Corporation files that are specific to a given operating system A DLL might be available under Windows but not other operating systems If you write a CIN for multiple platforms you need a different variant of the V
42. Style Guide National Instruments Corporation 7 9 Professional G Developers Tools Reference Manual For Booleans the name should give an indication of which state corresponds to which function while still indicating the default state The following examples is a recommended format for a Boolean where true means reset but the default is false Reset Device F Free labels next to the Boolean can help clarify the meaning of each position on a switch as shown in Figure 7 5 Figure 7 5 Free Labels on a Boolean Control Enumerations versus Rings Rings and enumerations look identical on a front panel but they are different On a block diagram a ring is simply an integer numeric Rings have the appearance of a pop up menu associating each string with a number The strings can be set at edit time or at run time using an attribute node An enumeration is similar to a ring but the strings in the enumeration are really a part of the enumeration data type If you wire an enumeration to a Case Structure the Case Structure displays the names from the enumeration instead of the numbers Also if you pop up on an enumeration input of a function or subVI and create a control constant or indicator the resulting object also will be an enumeration With a ring you would simply get a numeric Because the names are really a part of the type you cannot change the names in an enumeration programmatically at run time Also you cannot compa
43. Windows RoboHelp from Blue Sky Software 800 459 2356 http www blue sky com Windows Doc To Help from WexTech Systems Inc 914 741 9700 http www wextech com Macintosh QuickHelp from Altura Software Inc 408 655 8005 http www altura com UNIX HyperHelp from Bristol Technology Inc 203 798 1007 http www bristol com Once you have created and compiled your help files you can add them to the Help menu of LabVIEW BridgeVIEW or your own custom application by placing them in the Help directory You also can link to them directly from a VI in one of two ways You can add a link using the VI Setup Documentation option Pop up on the VI connector pane of the VI for which you want to link a file Select VI Setup from the pop up menu and choose Documentation from the drop down menu In the Help Tag box type the topic you want to link to in the help file Choose the help file by clicking the Browse button The path of the file appears in the Help Path box Now users can access this link from the Help window If the VI is a subVI on another block diagram you can pop up on the subVI icon and select Online Help to link to the selected topic in the specified help file You can use the Help functions from the Functions Application Control Help palette to link to topics in specific help files programmatically Chapter 6 Creating Documentation National Instruments Corporation 6 5 Profes
44. additional guidelines as the project progresses A style checklist is included at the end of this chapter to help you maintain consistency and quality as you develop VIs To save time review the list before and during development VI Hierarchy Organize your VIs in the file system to reflect the hierarchical nature of your software Make the top level VIs directly accessible Place subVIs in subdirectories and group them to reflect any modular components you have designed such as instrument drivers configuration utilities and file I O drivers Chapter 7 Using Consistent Style The G Style Guide Professional G Developers Tools Reference Manual 7 2 National Instruments Corporation Create a directory for all the VIs for one application and give it a meaningful name as shown in Figure 7 1 Save the main VIs in this directory and the subVIs in a subdirectory If the subVIs have subVIs continue the directory hierarchy downward Figure 7 1 Directory Hierarchy When naming VIs VI libraries and directories avoid using characters that are not accepted by all file systems such as slash backslash colon tilde and so on With the exception of Windows 3 1 most operating systems accept long descriptive names for files up to 31 characters on a Macintosh and 255 characters on other platforms Refer to the Multiplatform Issues section of Chapter 11 Source Code Control Tools for more information on filename limits fo
45. are easier to read and navigate online The designer should talk through the design The reviewers compare the description to the actual implementation The reviewers should consider many of the same issues included in a design review During a code walkthrough many of the following questions might be asked and answered What happens if a specific VI or function returns an error Are errors dealt with and or reported correctly Are there any race conditions An example of a race condition is a block diagram that reads from and writes to a global variable There is the potential a parallel block diagram could simultaneously attempt to manipulate the same global variable resulting in loss of data Chapter 3 Incorporating Quality into the Development Process Professional G Developers Tools Reference Manual 3 12 National Instruments Corporation Is the block diagram implemented well Are the algorithms efficient in terms of speed and or memory usage For more information refer to Chapter 28 Performance Issues in the G Programming Reference Manual Is the block diagram easy to maintain Has the developer made good use of hierarchy or is he or she placing too much functionality in a single VI Does the developer adhere to established guidelines There are a number of other features you can look for in a code walkthrough Take notes on the problems you encounter and add them to a list you can use as a guideline for
46. box 11 23 managing multiple hierarchies 11 17 overview 11 17 project groups 11 22 to 11 23 removing files from projects 11 21 SCC File Wizard 11 20 SCC Project dialog box 11 18 updating projects 11 20 to 11 21 Index Professional G Developers Tools Reference Manual I 8 National Instruments Corporation quality control considerations 3 2 to 3 3 quickstart guide 11 2 to 11 4 report generation 11 34 to 11 36 SCC File History 11 31 to 11 32 selecting system for source code control 11 4 to 11 6 built in system 11 5 to 11 6 third party systems 11 6 to 11 7 System History 11 32 using files instead of VI libraries 11 2 Source Lines of Code SLOCs metric 8 1 See also size based metrics in estimation 5 2 to 5 3 spiral model 2 9 to 2 11 standards See software quality standards statistics See VI Metrics tool stub VIs 4 9 style guidelines 7 1 to 7 29 block diagram 7 17 to 7 25 adding common threads 7 19 Code Interface Nodes CINs 7 25 data dependency 7 19 error checking 7 21 to 7 23 execution sequence 7 18 to 7 21 labeling 7 18 left to right layouts 7 18 missing dependencies 7 20 to 7 21 optimization 7 24 Sequence Structures 7 20 sizing and positioning 7 23 to 7 24 wiring etiquette 7 17 connector panes 7 14 to 7 15 controls and indicators 7 8 to 7 13 attribute nodes 7 11 default values ranges and coercion 7 10 to 7 11 descriptions 7 8 enumerations vs rings 7 9 key navigation 7 11
47. components and their interaction but it does not define the structure of each component You also determine the external interfaces and tools that will be used in the project Examples include decisions on System Requirements Software Requirements Architectural Design Detailed Design Coding Testing Maintenance Chapter 2 Development Models Professional G Developers Tools Reference Manual 2 6 National Instruments Corporation hardware such as plug in boards and external pieces of software such as databases or other libraries Detailed design Examines the software components defined in the architectural design stage and produces a specification for how each component is implemented Coding Implements the detailed design specification Testing Determines whether the software meets the specified requirements and finds any errors present in the code Maintenance Performed as needed to deal with problems and enhancement requests after the software is released In some organizations each change is reviewed by a change control board to ensure that quality is maintained You also can apply the full waterfall development cycle model when you implement these change requests In each stage you create documents that explain your objectives and describe the requirements for that phase At the end of each stage you hold a review to determine whether the project can proceed to the next stage
48. controls should not be regarded as tedious requirements that impede development Most of them help streamline development so problems are found before they are in the software when it is inexpensive to fix them Quality Requirements Set the quality standards for your product during the requirements stage The desired quality level should be treated as a requirement just like other requirements Weigh the merits and costs of various options you have for applying quality measures to your project Some of the trade offs you should consider include speed versus robustness and ease of use versus power and complexity For short projects that will be used only in house as tools or quick prototypes you do not need to emphasize robustness For example if you decide to develop a VI to benchmark I O and graphing speeds error checking is not as crucial However with more complicated projects that must be reliable such as applications for monitoring and controlling a factory process the software should deal with invalid input gracefully For example if an operator mistakenly selects invalid voltage or current settings your application Chapter 3 Incorporating Quality into the Development Process Professional G Developers Tools Reference Manual 3 2 National Instruments Corporation should deal with it appropriately Institute as many safeguards as possible to prevent problems Select a lifecycle development model that helps you find prob
49. for other forms of testing that rigorously test each component to verify that it meets stated objectives Because this type of testing is done late in the development process it is difficult and costly to incorporate changes suggested as a result Formal Methods of Verification Some software engineers are proponents of formal verification of software Other testing methodologies attempt to find problems by exploration but formal methods attempt to prove the correctness of software mathematically Chapter 3 Incorporating Quality into the Development Process Professional G Developers Tools Reference Manual 3 10 National Instruments Corporation The principal idea is to analyze each function of a program to determine if it does what you expect You mathematically state the list of preconditions before the function and the postconditions that are present as a result of the function This process can be performed either by starting at the beginning of the program and adding conditions as you work through each function or by starting at the end and working backward developing a set of weakest preconditions for each function Appendix A References lists documents that contain information on this process This type of testing becomes more complex as more and more possible paths of execution are added to a program through the use of loops and conditions Many people believe that formal testing presents interesting ideas for looking at soft
50. goals of the standard is to make it as consistent as possible with ISO 9001 and a supplement to ISO 9001 ISO CD 13485 These FDA standards are largely consistent with ISO 9001 but there are some differences Specifically the FDA did not think ISO 9001 was specific enough about certain requirements so the FDA clearly outlined them in its rules Refer to the FDA Internet home page at http www fda gov for more information on the new CGMP rules and how they compare to ISO 9001 Capability Maturity Model CMM In 1984 the United States Department of Defense created the Software Engineering Institute SEI to establish standards for software quality The SEI developed a model for software quality called the Capability Maturity Model CMM The CMM focuses on improving the maturity of an organization s processes Whereas ISO establishes only two levels of conformance pass or fail the CMM ranks an organization into one of five categories Level 1 Initial The organization has few defined processes quality and schedules are unpredictable Level 2 Repeatable The organization establishes policies based on software engineering techniques and previous projects that allow repeated success Groups use configuration management tools to manage projects Also they track software costs features and schedules Project standards are defined and followed Although the groups can deal with similar projects based on this experience their pr
51. if the menu is hidden Hiding menu bars and using dialog box style makes Help and VI descriptions inaccessible You can add a Help button on the front panel and design it to show the Help window or help file entries programmatically Remember that you can abort a VI by using the following keyboard shortcuts lt Ctrl period gt Windows lt Cmd period gt Macintosh lt meta period gt Sun lt Alt period gt HP UX Hide the Abort button if the user should not abort the VI Hiding the Abort button disables the keyboard shortcut for aborting the VI You should provide a front panel Boolean Stop button for VIs that loop You can hide the single stepping and execution highlighting buttons to save a small amount of execution time when the VI is finished by turning off the Allow Debugging option However these debugging tools often are useful to a user trying to understand how the block diagram works Chapter 7 Using Consistent Style The G Style Guide Professional G Developers Tools Reference Manual 7 14 National Instruments Corporation Connector Panes Consider selecting a connector pattern with extra terminals You can leave these extra terminals unconnected That way you do not have to change the connector pattern for your VI if you later find that you need another input or output Changing patterns requires replacing the subVI in all calling VIs By adding extra unused terminals you can add an input
52. is that other platforms might not Table 7 1 Examples of Font Styles and When to Use Each Font Description of Use Application Font Bold Controls and indicators of primary importance Dialog Font Controls and indicators of primary importance groups of controls or titles indicators and controls on pop up panels Application Font Plain Secondary indicators or controls used as constants groups of controls or titles Chapter 7 Using Consistent Style The G Style Guide Professional G Developers Tools Reference Manual 7 6 National Instruments Corporation have as many colors available Also some users have black and white monitors that cannot display certain color combinations well For example black and white monitors display black letters on a red background as all black Use a minimal number of colors emphasizing black white and gray The following are some simple guidelines for using color Never use color as the sole indicator of device state People with some degree of color blindness 5 of men might not detect the change Also multiplot graphs and charts can lose meaning when displayed in black and white Use line styles in addition to color Use light gray white or pastel colors for backgrounds Select bright highlighting colors only when the item is important such as an error notification Always check your VI on other platforms and on a black and white monitor Be consiste
53. it also deletes all previous versions of the file the SCC system maintains and the history log for that file Also you should enable the Display Projects option in the SCC Advanced dialog box to verify that the files you want to delete are not used currently by any other projects SCC File History Every Source Code Control transaction that modifies the contents of the SCC system is recorded When you create projects add files to projects check files in and out or delete files or projects that information is logged The comments you enter when you check in a file are added to the log for a file To view the SCC history information for a file select Project Source Code Control Advanced Click the File History button in the SCC Advanced dialog box to display a scrolling list of the SCC history for the file including dates and names for every person who modified the file It is important to understand the difference between the SCC file history and the VI history you modify with a VI History window You can use the VI History window as a place to enter notes about changes to a VI as you make them This VI history is a part of the VI If you give the VI to someone else the VI history is still present unless you reset it using an option from the History window When you check in a file regardless of whether it is a VI or another document such as a specification you are given a chance to make an entry in the SCC file history For VIs
54. later in this chapter for more information Chapter 11 Source Code Control Tools National Instruments Corporation 11 33 Professional G Developers Tools Reference Manual Accessing Previous Versions of Files Most SCC systems automatically maintain previous versions of files This is helpful if you ever make a mistake and need to recall an older version of a file It also is useful if you give a version of a file to a customer continue development and subsequently need to retrieve the same version you sent the customer so you can reproduce the system he or she has Built In System The built in SCC system supports maintaining previous versions of files The system administrator can enable this feature but he or she might choose to disable it for disk storage reasons Maintaining older versions of files can dramatically increase your storage requirements In addition the administrator can configure the SCC system so it maintains only a limited number of previous versions of each file In this case as you check in a newer version of a file a fixed number of previous versions will be maintained If you label versions of files with the built in system the labeled versions are not automatically deleted and are not counted as part of this system administrator limit Labeled versions are maintained until you choose to delete them With the built in system you can access previous versions of files from the SCC View File History and t
55. listbox to the right To view the differences on the screen double click an item in the listbox or click the Show Differences button The Read Hierarchies button categorizes the VIs in the hierarchy VIs that need to be compared are categorized as not compared You can selectively compare individual VIs by double clicking an item or clicking the Show Differences button Chapter 10 VI Comparison Tools National Instruments Corporation 10 3 Professional G Developers Tools Reference Manual To abort comparisons of large VI hierarchies use the Operate Stop menu item or press the lt Ctrl gt Control and the period key combination Comparison Options You selectively can find differences in the front panel and block diagram of a VI and VI attributes such as settings in VI Setup For the block diagram you can choose to ignore cosmetic differences A cosmetic change is any change that does not affect the execution of the block diagram Furthermore you can choose to ignore the position and size changes in front panel and block diagram objects Position and size changes include movement of an object from front to back and vice versa Show Differences Differences are shown by tiling the front panels and block diagrams of the two VIs in the Differences window as shown in Figure 10 2 Figure 10 2 Differences Window The Differences window includes a list of differences and details of the selected difference To highlight a differe
56. modules if problems are encountered or as part of a more detailed regression test that is applied periodically during development System Testing System testing happens after integration to determine whether the product meets customer expectations and to make sure the software works as expected within the hardware system This can be done first as a set of black box tests to verify that the requirements have been met Most LabVIEW and BridgeVIEW applications perform some kind of I O The application also might communicate with other applications With system testing you test the software to make sure it fits into the overall system as expected When testing the system you will ask and answer questions such as the following Are performance requirements met If my application communicates with another application does it deal with an unexpected failure of that application well You can complete this testing with alpha and beta testing Alpha and beta testing serve to catch test cases that might not have been considered or completed by the developers With alpha testing a functionally complete product is tested in house to see if any problems are found When alpha testing is complete the product is beta tested by customers in the field Alpha and beta testing are the only testing mechanisms for some companies This is unfortunate because alpha and beta testing actually can be inexact Alpha and beta testing are not a substitute
57. of a cluster border to group controls that are not actually in a cluster For subVI front panels the user does not see you can place the objects so they correspond to the connector pattern Generally inputs should be on the left and outputs on the right Sizing and Positioning Front Panels Front panels should fit on a monitor that is the standard size for most intended users Make the window as small as possible without crowding controls or sacrificing a good layout If your VIs are intended for in house use and everyone has a large monitor design large front panels If you are Chapter 7 Using Consistent Style The G Style Guide Professional G Developers Tools Reference Manual 7 8 National Instruments Corporation doing commercial development keep in mind that not everyone has a large monitor Front panels should open in the upper left corner of the screen for the convenience of users with small screens Sets of VIs that are often opened together should be placed so the user can see at least a small part of each Place front panels that open automatically in the center of the screen by selecting the Auto Center option in the Windows Options version of the VI Setup dialog box to optimize this for monitors of various sizes Moving a window is not considered a modification within the VI editor To save the VI with the windows properly placed make a small change such as moving a control by one pixel then moving it back and save t
58. of the familiar structures and wire them together on paper This is a good way to think things through sometimes with the help of other G programmers Pseudocode Configuration Data Structure FOR each module defined IF module is active THEN FOR each channel IF channel is active THEN Read_Data module channel Store data in output array ENDIF ENDFOR ENDIF ENDFOR FOR each module defined IF module is active THEN FOR each channel IF channel is active THEN Read_Data module channel Store data in output array ENDIF ENDFOR ENDIF ENDFOR Chapter 4 Prototyping and Design Techniques Professional G Developers Tools Reference Manual 4 6 National Instruments Corporation If you are not sure how a certain function will work prototype it in a simple test VI as shown in Figure 4 4 Artificial data dependency between the initialization VIs and the main While Structure in Figure 4 4 eliminates the need for a Sequence Structure Figure 4 4 Data Flow for a Generic Data Acquisition Program Finally you are ready to write the program in G Remember to make your code modular building subVIs when there is a logical division of labor or the potential for code reuse Solve the more general problems along with your specific ones Test your subVIs as you write them This might involve constructing higher level test routines It is much easier to catch the bugs in one small module than in a large hierarchy of VIs Bottom Up Desig
59. other walkthroughs Focus on technical issues when doing a code walkthrough Remember to review only the code not the developer who produced it Try not to focus only on the negative and be sure to raise positive points Appendix A References lists documents that contain information on walkthrough techniques Post Mortem Evaluation At the end of each stage in the development process you should consider having a post mortem meeting to discuss what has gone well and what has not Each developer should evaluate the project and be honest in discussing obstacles that reduce the quality level of the project Each developer should consider the following questions What are we doing right What is working well What are we doing wrong What can we improve Are there specific areas of the design code that need a lot of work Is a design review or code walkthrough of that section necessary Are the quality systems working Could we catch more problems if we changed the quality requirements Are there better ways to get the same results Post mortem meetings at major milestones can help to correct problems mid schedule instead of waiting until the release is complete Chapter 3 Incorporating Quality into the Development Process National Instruments Corporation 3 13 Professional G Developers Tools Reference Manual Software Quality Standards As software has become a more critical component in systems concern
60. platform you are using automatically In general you will not need to change this setting Refer to the Multiplatform Issues section later in this chapter for information on the how the platform information is used and a description of situations when you might want to change it Managing Source Code Control Projects The following sections outline how to create and update a Source Code Control project how to add or delete files from a project and how to work with project groups Source Code Control Projects Overview The G Source Code Control tools help you create projects under Source Code Control A project is primarily a single VI hierarchy which is a VI and all or some of its subVIs In addition an SCC project also can contain extra project related files such as specifications shared libraries and external subroutines The G SCC tools can maintain multiple projects If you create two projects that contain the same subVI only one copy of that subVI is maintained on the server By creating a project based on a VI hierarchy the G SCC tools can help you keep the SCC project up to date As you add files to or remove files from your hierarchy the G SCC tools notice the changes and help you update the project Managing Multiple Hierarchies Some applications you develop might have more than one hierarchy For example if you use the VI Control VIs to dynamically load a VI you have one hierarchy for the main set of VIs and another f
61. same name as the VI for example Alarm Boolean ctl has the default name Alarm Boolean Block Diagram Checklist K Avoid creating extremely large block diagrams Limit them to one to two screens if possible K Label controls important functions subVIs constants attribute nodes local variables global variables and structures K Add comments Use object labels instead of free labels where applicable and scrollable strings for long comments K Make comment backgrounds transparent to distinguish from name labels K Place labels below objects when possible and right justify text if label is placed to the left of an object Chapter 7 Using Consistent Style The G Style Guide National Instruments Corporation 7 29 Professional G Developers Tools Reference Manual K Use standard consistent font conventions throughout K Use Size to Text for all text and add carriage returns if necessary K Reduce white space in smaller block diagrams but allow at least 3 4 pixels between objects K Flow data from left to right Wires enter from the left and exit to the right not the top or the bottom K Align and distribute functions terminals and constants K Label long wires with small transparent labels K Do not wire behind objects K Make good use of reusable testable subVIs K Make sure the program can deal with error conditions and invalid values K Show name of source code or include source code for
62. something different from what they have built already Consequently a lot of code is developed reworked or thrown away unnecessarily Clearly Define the Requirements of Your Application Before you develop a detailed design of your system you should define your goals as clearly as possible Begin by making a list of requirements Some requirements are specific such as the types of I O sampling rates or the need for real time analysis You need to do some research at this early stage to be sure you can meet the specifications Other requirements depend on user preference such as file formats or graph styles Try to distinguish between absolute requirements and desires You might be able to satisfy all requests but it is best to have an idea about what you can sacrifice if you run out of time Also be careful that the requirements are not so detailed that they constrain the design For example when you design an I O system the customer probably has certain sampling rate and precision requirements He or she also is constrained by cost You should include those issues in your requirements However if you can avoid specifying the operating system and hardware you can adjust your design after you begin prototyping and benchmarking various components As long as the costs are within budget and the timing and precision issues are met the customer might not care whether the system uses a particular type of plug in card or other hardware
63. stubbed out as described in the Unit Testing section earlier in this chapter Once you have verified that the existing components work together within the existing framework you can enable additional components With a bottom up approach you test low level modules first and gradually work up toward the high level modules Begin by testing a small number of components combined into a simple system such as the driver test described in the Unit Testing section earlier in this chapter After you have combined a set of modules and verified that they work together add components and test them with the already debugged subsystem The bottom up approach consists of tests that gradually increase their scope while the top down approach consists of tests that are gradually refined as new components are added Regardless of the approach you take you must perform regression testing at each step to verify that the features that already have been tested still work Regression testing consists of repeating some or all previous tests Because you might need to perform the same tests numerous times you Chapter 3 Incorporating Quality into the Development Process National Instruments Corporation 3 9 Professional G Developers Tools Reference Manual might want to develop representative subsets of tests to use for frequent regression tests These components can be run at each stage while the more detailed tests can be run to test an individual set of
64. the new version of the file in to Source Code Control The file becomes part of the master copy of the project If incorrect changes are made most Source Code Control systems allow you to access previous versions of files SCC tools help track changes to your project When a developer checks in a file SCC tools ask the user to describe the changes This information is maintained so you can clearly document the evolution of your project In addition to maintaining the source code SCC tools can manage all aspects of your project including specifications and illustrations They also can keep track of the changes made to those documents The ability to track the evolution of software is important to most organizations that are concerned with quality Chapter 11 Source Code Control Tools Professional G Developers Tools Reference Manual 11 2 National Instruments Corporation Using Individual Files Instead of VI Libraries VI libraries LLBs give you a method of storing multiple VIs within the same file The main advantage of this is that it allows you to create VIs with long descriptive names even under Windows 3 1 in which filenames are limited to 8 3 characters in length When you store VIs in an LLB only the VI library name itself needs to be limited to 8 3 characters in length You should not use VI libraries for files you want to put under Source Code Control VI libraries are not practical for SCC because SCC tools cannot manage
65. the user starts your application For each front panel the user interacts with provide a picture of the front panel and a description of the major controls and indicators Organize the front panel descriptions in a top down fashion with the first front panels the user sees documented first As described in the previous section you can use the Print Documentation dialog box or the Documentation tool to create this documentation Chapter 6 Creating Documentation Professional G Developers Tools Reference Manual 6 4 National Instruments Corporation Creating Help Files You can create your own online help or reference documents if you have the right development tools Online help documents are based on formatted text documents You can create these documents using a word processing program such as Microsoft Word or using one of the tools described later in this section Special help features such as links and hotspots are created as hidden text You can use the Print Documentation dialog box or the Documentation tool to help you create the source material for your help documents Once you have created source documents use a help compiler to create a help document If you need help files on multiple platforms you must use the help compiler for the specific platform on which the help files will be used You might want to use any of the following compilers The Windows compilers also include tools for creating help documents
66. to 7 12 labels 7 8 to 7 9 local variables 7 12 to 7 13 front panels 7 4 to 7 8 color 7 5 to 7 6 consistency 7 4 graphics and custom controls 7 6 to 7 8 layout 7 7 sizing and positioning 7 7 to 7 8 text 7 5 hierarchical organization of files 7 1 to 7 4 directories folders 7 1 to 7 2 naming VIs VI libraries and directories 7 2 VI libraries 7 3 to 7 4 icons 7 15 to 7 16 problems with inconsistent developer styles 3 10 style checklist 7 26 to 7 29 block diagram 7 28 to 7 29 front panel 7 27 to 7 28 VIs 7 26 to 7 27 VI setup 7 13 subVI interface statistics 8 5 subVI library documenting 6 2 to 6 3 System History dialog box 11 32 system testing 3 9 T technical support B 1 to B 2 telephone and fax support numbers B 2 testing guidelines 3 5 to 3 10 black box and white box testing 3 6 formal methods of verification 3 9 to 3 10 integration testing 3 8 to 3 9 system testing 3 9 unit testing 3 7 text style guidelines 7 5 top down design 4 2 to 4 6 tracking changes 3 4 Index National Instruments Corporation I 9 Professional G Developers Tools Reference Manual tracking projects See project management SCC tools scheduling and project tracking U unit testing 3 7 U S Food and Drug Administration FDA standards 3 14 user documentation See documentation of applications user interface statistics 8 4 username SCC 11 29 to 11 30 V verification methods 3 9 to 3 10
67. to understand the difference between the working directory which is where you do your work and the master directory which is where SCC stores the latest versions of files Users will not modify the master directory except when they check in files or create projects With SourceSafe the tools take care of copying files from the SourceSafe database to your working directory or vice versa With ClearCase your work directory is the same directory as the master directory ClearCase uses a virtual file system model that allows multiple users to have a unique view and set of files in the same directory Refer to the ClearCase section later in this chapter for more information 3 Users set up VIs for use with the SCC tools As mentioned above all files that the user will work with must be in the working directory or one of its subdirectories In addition files that will be stored under SCC cannot be stored in LLBs LLBs are not flexible enough for them to work well with an SCC system because they do not allow for easy access to individual files You can select Project File Manager to convert your LLBs to directories of VIs In converting LLBs to directories you might find that you have some files with names that cannot be managed by the file system for Chapter 11 Source Code Control Tools Professional G Developers Tools Reference Manual 11 4 National Instruments Corporation example it contains a separator character such as
68. user of the G SCC tools will have configured the platform for which they want files by selecting Project Source Code Control Local Configuration Assuming you do not modify this list the SCC Local Configuration dialog box should have automatically detected your platform correctly Chapter 11 Source Code Control Tools National Instruments Corporation 11 39 Professional G Developers Tools Reference Manual Variants of a File for Different Platforms To create a variant of a file for another platform select Project Source Code Control Project to display the SCC Project dialog box Select a project that contains the file and click the Edit Project button to display the SCC Edit Project File List dialog box Click the Platforms button to display the SCC Edit File Platforms dialog box To create a new variant click the Create a Variation button Choose the new variant and select the platforms to which it applies If necessary modify the existing variants to ensure there is no overlap The SCC Edit File Platforms dialog box does not allow you to apply multiple variants to the same platform Retrieving Files for a Different Platform In some cases you might need to retrieve files for a different platform For example if you create a CIN you will have different versions for each platform Suppose you have a VI that calls a CIN and at some point you decide to add a parameter to the CIN You will first check out the VI on a
69. usually take longer to draw than small ones For instance you could import several pictures of valves and pipes individually instead of importing one large picture Front Panel Layout Consider the arrangement of controls on front panels Keep front panels simple to avoid confusing the user For top level VIs that users see place the most important controls in the most prominent positions Use the Align Objects and the Distribute Objects drop down menus to create a uniform layout Use Edit Panel Order to arrange controls in a logical sequence Refer to the Key Navigation section later in this chapter for more information Do not overlap controls with other controls or with their own label digital display or other parts unless you are trying to achieve a special effect Overlapped controls are much slower to draw and might flash Place any Start or Stop buttons near the Run button on the toolbar for two reasons The buttons are easier to find and the Stop button will be more prominent than the Abort button if you did not hide it The user will be less likely to abort the VI by accident Use simple elements such as rounded rectangles to visually group objects with related functions Use clusters to group related data However do not use clusters for aesthetic purposes only It makes connections to your VI more difficult to understand Avoid importing graphic objects that are inanimate copies of real controls For instance do not use a copy
70. you can use this in your own applications Notice that the While Loop stops if it detects an error Figure 7 11 Example of How to Use an Error Cluster Sizing and Positioning of Block Diagrams Like the front panel the block diagram should fit the user s monitor The amount and density of wiring on a diagram often indicate the skill forethought and intentions of the programmer Having to remove a section of code and put it in a subVI because you ran out of space is a sign of not using effective top down design When the front panel and block diagram fit on an average sized monitor place the block diagram to the right of or below the front panel This arrangement gives users the optimum view of your program When the front panel and block diagram do not fit on one screen place the block diagram in the upper left corner of the screen If possible show the title bar of the front panel and the block diagram To set the window position make a small change such as modifying or moving any object and changing it back and save or select File Save As and use the same name Chapter 7 Using Consistent Style The G Style Guide Professional G Developers Tools Reference Manual 7 24 National Instruments Corporation Figure 7 12 illustrates how a front panel and a block diagram can fit comfortably on a small monitor with room to spare for the Help window Figure 7 12 Well Placed Front Panel and Block Diagram Optimization There ar
71. your software You should create several documents for software you develop The two main categories for this documentation are as follows Design related documentation Requirements specifications detailed design plans test plans and change history documents are examples of the kinds of design related documents you might need to produce User documentation User documentation consists of printed manuals and online help files that explain how to use your software The style of each of these documents is different Design related documentation generally is written for an audience with extensive knowledge of the tools they are using User documentation is written for an audience with a lesser degree of understanding The size and style of each document can vary according to the type of project For simple tools that will be used only in house you might not need to do much of either If you plan to sell a product you must allow a significant amount of time to develop detailed user oriented documentation that describes the product For products that must go through a quality certification process such as a review by the U S Food and Drug Administration you must ensure that the design related documentation is as detailed as required Developing Design Related Documentation The format and detail level of the documentation you develop for requirements specifications and other design related documentation is determined by
72. 11 27 deleting files from SCC 11 31 Edit Change Comments dialog box 11 29 file properties 11 25 file status 11 24 to 11 25 History window for documenting changes 11 27 labeling versions of files for easy retrieval 11 34 managing project related files 3 3 previous versions of files 3 3 to 3 4 11 33 retrieving files 11 23 to 11 25 SCC Check Files In dialog box 11 28 SCC Check Files Out dialog box 11 26 SCC File Properties dialog box 11 25 SCC Retrieve Files dialog box 11 24 SCC user name 11 29 to 11 30 tracking changes 3 4 administrator setup 11 5 to 11 9 built in system 11 8 to 11 9 ClearCase 11 10 to 11 12 Edit Platform List 11 13 to 11 14 Visual SourceSafe 11 9 to 11 10 advanced features 11 30 to 11 36 general concepts 11 1 local configuration 11 14 to 11 17 built in system 11 15 ClearCase 11 15 to 11 16 local work directory 11 16 to 11 17 Platform drop down menu 11 17 Visual SourceSafe 11 15 multiplatform issues 11 36 to 11 39 cross platform source code control 11 36 filename limitations 11 36 to 11 37 platform dependent SCC files 11 37 to 11 39 platform specific files 11 38 retrieving files for different platforms 11 39 variants of files for different platforms 11 39 overview 3 3 project management 11 17 to 11 23 adding extra files 11 21 to 11 22 creating projects 11 18 to 11 20 Edit Extra Files dialog box 11 22 Edit Project File List dialog box 11 19 Edit Project Group dialog
73. 3 VI and control descriptions 6 5 to 6 6 control and indicator descriptions 6 6 self documenting front panels 6 5 VI description 6 5 Documentation Tool dialog box 9 1 to 9 2 Add Directory button 9 2 Add File button 9 2 Add Hierarchy button 9 2 Add LLB button 9 2 Create Help Source button 9 2 Create HTML File button 9 2 Create RTF File button 9 2 illustration 9 1 Print button 9 2 Save Script button 9 2 E Edit Extra Files dialog box 11 22 Edit Platform List dialog box 11 13 to 11 14 Edit Project File List dialog box 11 19 Edit Project Group dialog box 11 23 effort estimation 5 4 See also estimation electronic support services B 1 to B 2 e mail support B 2 enumerations vs rings 7 9 error checking 7 21 to 7 23 estimation 5 1 to 5 6 COCOMO estimation 5 6 of effort 5 4 feature creep 5 1 function point estimation 5 6 lines of code number of nodes 5 2 to 5 3 mapping estimates to schedules 5 6 to 5 7 overview 5 1 to 5 2 problems with size based metrics 5 3 to 5 4 wideband Delphi estimation 5 5 execution sequence 7 18 to 7 21 adding common threads 7 19 data dependency 7 19 left to right layouts 7 18 missing dependencies 7 20 to 7 21 Sequence Structures 7 20 F fax and telephone support numbers B 2 Fax on Demand support B 2 FDA U S Food and Drug Administration standards 3 14 feature creep 5 1 file management SCC tools 11 23 to 11 30 change control 3 4 to 3 5 checking in fil
74. Benchmarking 4 10 Identify Common Operations 4 11 Contents National Instruments Corporation vii Professional G Developers Tools Reference Manual Chapter 5 Scheduling and Project Tracking Estimation 5 1 Source Lines of Code Number of Nodes Estimation 5 2 Problems with Source Lines of Code and Number of Nodes 5 3 Effort Estimation 5 4 Wideband Delphi Estimation 5 5 Other Estimation Techniques 5 6 Mapping Estimates to Schedules 5 6 Tracking Schedules Using Milestones 5 7 Responding to Missed Milestones 5 8 Chapter 6 Creating Documentation Developing Design Related Documentation 6 1 Developi
75. BridgeVIEW and LabVIEW Professional G Developers Tools Reference Manual Professional G Developers Tools Reference Manual May 1998 Edition Part Number 321393B 01 Internet Support E mail support natinst com FTP Site ftp natinst com Web Address http www natinst com Bulletin Board Support BBS United States 512 794 5422 BBS United Kingdom 01635 551422 BBS France 01 48 65 15 59 Fax on Demand Support 512 418 1111 Telephone Support USA Tel 512 795 8248 Fax 512 794 5678 International Offices Australia 03 9879 5166 Austria 0662 45 79 90 0 Belgium 02 757 00 20 Brazil 011 288 3336 Canada Ontario 905 785 0085 Canada Qu bec 514 694 8521 Denmark 45 76 26 00 Finland 09 725 725 11 France 01 48 14 24 24 Germany 089 741 31 30 Hong Kong 2645 3186 Israel 03 6120092 Italy 02 413091 Japan 03 5472 2970 Korea 02 596 7456 Mexico 5 520 2635 Netherlands 0348 433466 Norway 32 84 84 00 Singapore 2265886 Spain 91 640 0085 Sweden 08 730 49 70 Switzerland 056 200 51 51 Taiwan 02 377 1200 United Kingdom 01635 523545 National Instruments Corporate Headquarters 6504 Bridge Point Parkway Austin Texas 78730 5039 USA Tel 512 794 0100 Copyright 1997 1998 National Instruments Corporation All rights reserved Important Information Warranty The media on which you receive National Instruments software are warranted not to fail to execute programming instructions due to defects in materials and w
76. Chapter 11 Source Code Control Tools Professional G Developers Tools Reference Manual 11 28 National Instruments Corporation Checking In Files When you finish making changes to a file you have checked out select Project Source Code Control Check Files In to display the SCC Check Files In dialog box as shown in Figure 11 13 This dialog box lets you copy your version of the file into Source Code Control so that it is available to other users The VI is locked automatically as it is checked in to prevent you or others from accidentally modifying the file without first checking it out Figure 11 13 SCC Check Files In Dialog Box The interface for checking in files is similar to that for checking out files and for retrieving files You can check in a file only if it is checked out to you Your username must be the same as when you checked out the file When you check in a file you are prompted to enter a summary of the changes you made If you used the History window to record changes the SCC Edit Change Comments dialog box initially contains the history text since you checked out the file as shown in Figure 11 14 Chapter 11 Source Code Control Tools National Instruments Corporation 11 29 Professional G Developers Tools Reference Manual Figure 11 14 Edit Change Comments Dialog Box You can edit this text to expand the information or to remove unimportant information When you change this text you are not modifying
77. Corporation G 1 Professional G Developers Tools Reference Manual Glossary A Application Programming Interface The programming interface for controlling some software packages such as Microsoft Visual SourceSafe B black box testing A form of testing where a module is tested without knowing how the module is implemented The module is treated as if it were a black box that you cannot look inside Instead you generate tests to verify the module behaves the way it is supposed to according to the requirements specification C Capability Maturity Model CMM A model for judging the maturity of the processes of an organization and for identifying the key practices that are required to increase the maturity of these processes The Software CMM SW CMM has become a de facto standard for assessing and improving software processes Through the SW CMM the Software Engineering Institute and software development community have put in place an effective means for modeling defining and measuring the maturity of the processes software professionals use CIN See Code Interface Node COCOMO Estimation COnstructive COst MOdel A formula based estimation method for converting software size estimates to estimated development time code and fix model A lifecycle model that involves developing code with little or no planning fixing problems as they arise Glossary Professional G Developers Tools Reference Manual G 2 National Ins
78. I use the History window to document your changes K Create a meaningful black and white icon Color icons are optional Chapter 7 Using Consistent Style The G Style Guide National Instruments Corporation 7 27 Professional G Developers Tools Reference Manual K Make a connector pane Provide in and out data flow Leave extra inputs and outputs for later development Use consistent layout K Consider VI and window options carefully Remember the following Do not set higher priority without serious thought Remember that hiding menu bars and using dialog box style makes Help and VI descriptions inaccessible Hiding Abort and debugging buttons increases performance slightly K Set print options to print attractive output in the most useful format K Make test VIs that check error conditions invalid values and Cancel buttons K Save test VIs in a separate directory so you can reuse them K Load and test VIs on multiple platforms making sure labels fit and window size and position are correct Front Panel Checklist K Give controls meaningful names Use consistent capitalization K Make name label backgrounds transparent K Check for consistent placement of control names for example upper left K Use standard consistent fonts throughout all front panels K Use Size to Text for all text for portability and add carriage returns if necessary K Use Required Recommended and Option
79. I that contains the CIN for each platform The SCC Edit File Platforms dialog box deals with both issues because it lets you mark a file as platform specific and lets you create variants of a file for different platforms Refer to the Multiplatform Issues section later in this chapter for more information The Exclude Dirs button lets you edit a list of directories that should be ignored as far as source code is concerned For example the files in the vi lib directory are not listed as candidates for SCC by default In general you do not need to change this setting although you might want to add a directory of your own if you have specific files you do not need to add to Source Code Control Updating a Project As you develop your VIs you create new subVIs and remove calls to subVIs The integrated SCC tools make it easy to keep the SCC project up to date To update the SCC project first open the top level VI for your project and then select Project Source Code Control Project Select the project in the SCC Projects dialog box and click the Edit Project button As always the files must be in your working directory and cannot be in LLBs unless they are in one of the excluded directories for the project By default files in vi lib are excluded SCC File Wizard When you edit a project using Project Source Code Control Project the SCC tools compare your hierarchy to the version that is already under SCC If there are di
80. Kodosky J MacCrisken and G Rymar Proceedings from IEEE Workshop on Visual Languages 1991 Also available from National Instruments Description of some of the theory behind the graphical programming paradigm of LabVIEW LabVIEW Graphical Programming Practical Applications in Instrumentation and Control Gary W Johnson McGraw Hill Inc 1994 ISBN 0 07 032719 4 An excellent overview of how to apply LabVIEW to real world problems LabVIEW Technical Resource Edited by Lynda P Gruggett LTR Publishing phone 214 706 0587 fax 214 706 0506 A quarterly disk of VIs and a newsletter that features technical articles about all aspects of LabVIEW Rapid Development Steve McConnell Microsoft Press Explanation of software engineering practices in a down to earth fashion with many examples and practical suggestions Microsoft Secrets Michael A Cusumano and Richard W Selby Free Press 1995 ISBN 0 02 874048 3 In depth examination of the programming practices Microsoft uses Contains interesting discussions of what Microsoft has done right and what it has done wrong Includes a good discussion of team organization scheduling and milestones Appendix A References Professional G Developers Tools Reference Manual A 2 National Instruments Corporation Dynamics of Software Development Jim McCarthy Microsoft Press 1995 ISBN 1 55615 823 8 Another look at what has worked and what has not for developers at Microsoft This
81. See also development models bottom up design 4 6 to 4 8 data acquisition system example 4 3 to 4 6 defining requirements for application 4 1 to 4 2 front panel prototyping 4 9 to 4 10 identifying common operations 4 11 to 4 12 instrument driver example 4 7 to 4 8 multiple developer considerations 4 8 to 4 9 performance benchmarking 4 10 top down design 4 2 to 4 6 design related documentation 6 1 to 6 2 development models 2 1 to 2 11 See also design techniques prototyping common pitfalls 2 1 to 2 3 lifecycle models 2 4 to 2 11 code and fix model 2 4 definition 2 4 G prototyping methods 2 8 modified waterfall model 2 7 prototyping 2 7 to 2 8 spiral model 2 9 to 2 11 waterfall model 2 5 to 2 7 Differences window 10 3 to 10 4 directories local work directory 11 16 to 11 17 naming 7 2 style considerations 7 2 VI search path 7 2 Document Tool command 9 1 Index National Instruments Corporation I 3 Professional G Developers Tools Reference Manual documentation for Professional G Developers Tools Reference conventions used in manual xiv xv organization of manual xiii xiv references A 1 to A 2 related documentation xv xvi documentation of applications 6 1 to 6 6 BridgeVIEW and LabVIEW features 6 2 design related documentation 6 1 to 6 2 Documentation tool 9 1 to 9 2 help files 6 4 overview 6 1 user documentation 6 2 to 6 3 application documentation 6 3 library of subVIs 6 2 to 6
82. See also testing guidelines VI Comparison tools 10 1 to 10 7 Compare Files command 10 7 Compare Hierarchies command 10 1 to 10 4 Compare VI Hierarchies dialog box 10 2 to 10 3 comparison options 10 3 showing differences 10 3 to 10 4 Compare VIs command 10 5 to 10 6 Compare VIs dialog box 10 5 Comparison Progress dialog box 10 6 renaming VIs for comparison 10 6 VI libraries avoiding with Source Code Control tools 11 2 documenting subVI libraries 6 2 to 6 3 files in vi lib excluded from VI Metrics tool 8 5 hierarchy with VI libraries 7 3 to 7 4 Windows 3 1 considerations 7 3 VI Metrics tool 8 1 to 8 5 dialog box 8 2 files in vi lib 8 5 number of nodes 8 2 to 8 3 purpose and use 8 2 to 8 3 saving metric information 8 5 statistics 8 3 to 8 5 block diagrams 8 3 to 8 4 CIN shared library statistics 8 4 globals locals statistics 8 4 subVI interface statistics 8 5 user interface 8 4 VI Search Path 7 2 VI setup 7 13 VIs description as documentation 6 5 hierarchy on disk 7 1 to 7 2 style checklist 7 26 to 7 27 Visual SourceSafe for Windows 95 NT accessing previous versions of files 11 33 administrator setup 11 9 to 11 10 advantages and disadvantages 11 5 local configuration 11 15 report generation 11 35 to 11 36 support for 11 5 W waterfall model 2 5 to 2 7 modified 2 7 white box testing 3 6 wideband Delphi estimation 5 5 Windows 3 1 restrictions on development note 1 1 saving VI
83. T TO RECOVER DAMAGES CAUSED BY FAULT OR NEGLIGENCE ON THE PART OF NATIONAL INSTRUMENTS SHALL BE LIMITED TO THE AMOUNT THERETOFORE PAID BY THE CUSTOMER NATIONAL INSTRUMENTS WILL NOT BE LIABLE FOR DAMAGES RESULTING FROM LOSS OF DATA PROFITS USE OF PRODUCTS OR INCIDENTAL OR CONSEQUENTIAL DAMAGES EVEN IF ADVISED OF THE POSSIBILITY THEREOF This limitation of the liability of National Instruments will apply regardless of the form of action whether in contract or tort including negligence Any action against National Instruments must be brought within one year after the cause of action accrues National Instruments shall not be liable for any delay in performance due to causes beyond its reasonable control The warranty provided herein does not cover damages defects malfunctions or service failures caused by owner s failure to follow the National Instruments installation operation or maintenance instructions owner s modification of the product owner s abuse misuse or negligent acts and power failure or surges fire flood accident actions of third parties or other events outside reasonable control Copyright Under the copyright laws this publication may not be reproduced or transmitted in any form electronic or mechanical including photocopying recording storing in an information retrieval system or translating in whole or in part without the prior written consent of National Instruments Corporation Trademarks BridgeVIEW
84. ____ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ List any error messages ___________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ The following steps reproduce the problem ___________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ Professional G Developers Tools Reference Manual Hardware and Software Configuration Form Record the settings and revisions of your hardware and software on the line to the right of each item Complete a new copy of this form each time you revise your software or hardware configuration and use this form as a reference for your current configuration Completing this form accurately before contacting National Instruments for technical support helps our applications engineer
85. a cross reference or an introduction to a key concept This font also denotes text from which you supply the appropriate word or value as in Windows 3 x monospace Text in this font denotes text or characters you should literally enter from the keyboard sections of code programming examples and syntax examples This font is also used for the proper names of disk drives paths directories programs subprograms subroutines device names functions operations variables filenames and extensions and for statements and comments taken from programs paths Paths in this manual are denoted using backslashes to separate drive names directories folders and files Platform Text in this font denotes information related to a specific platform Related Documentation The following documentation contains information you might find helpful as you read this manual BridgeVIEW User Manual LabVIEW User Manual LabVIEW Function and VI Reference Manual G Programming Reference Manual BridgeVIEW Online Reference available by selecting Help Online Reference LabVIEW Online Reference available by selecting Help Online Reference About This Manual Professional G Developers Tools Reference Manual xvi National Instruments Corporation Refer to Appendix A References for a list of additional documents you might find helpful as you read this manual and work on your development projects Custom
86. aflow model just for the sake of avoiding Sequence Structures completely is as bad as overusing them Use dataflow programming techniques to create a clear single page main program Adding Common Threads If you make a collection of subVIs that are used together often give them all a common input output terminal pair to chain them together without requiring Sequence or Case Structures A good example of a common thread is an error code Each VI should test the incoming error and not execute if there is an existing error then pass that error or its own error to the output The only exception to this rule is a function like the Close File function which must perform cleanup regardless of whether an error occurred previously The Close File function closes the specified file and passes error input as its output This error information is commonly kept in a cluster that contains a numeric error code a string that contains the name of the function that generated the error and an error Boolean for quick testing This technique is sometimes called Error In Error Out and is used in most of the I O libraries Figure 7 10 shows an example of how the data acquisition VIs use the error cluster The While Loop stops if an error is detected and the General Error Handler VI reports the error to the user at the end Notice the clean appearance of this style of programming Figure 7 10 Example of How Data Acquisition VIs Use Error Clusters Chapter 7 Usi
87. al G Developers Tools Reference Manual Identify Common Operations As you design your programs you might find that certain operations are performed frequently Depending on the situation this might be a good place to use subVIs or loops to repeat an action For example consider Figure 4 6 where three similar operations run independently Figure 4 6 Operations Run Independently An alternative to this design is a loop that performs the operation three times as shown in Figure 4 7 You can build an array of the different arguments and use auto indexing to set the correct value for each iteration of the loop Figure 4 7 Loop Performs Operation Three Times If the array elements are constant you can use an array constant instead of building the array on the block diagram Chapter 4 Prototyping and Design Techniques Professional G Developers Tools Reference Manual 4 12 National Instruments Corporation Some users mistakenly avoid using subVIs because they are afraid of the overhead it might add to their execution time It is true that you probably do not want to create a subVI from a simple mathematical operation such as the Add function especially if it must be repeated thousands of times However the overhead for a subVI is fairly small and usually is dwarfed by any I O you perform or by any memory management that might occur from complex manipulation of arrays National Instruments Corporation 5 1 Professional G Dev
88. al copy does not exist Either the file is a file on the server that you have never retrieved or you deleted it from your local system If you Chapter 11 Source Code Control Tools National Instruments Corporation 11 25 Professional G Developers Tools Reference Manual have intentionally deleted it and you want to update the project refer to the Updating a Project section earlier in this chapter Server copy does not exist Either the file has been deleted on the server by another developer or it is a new file you have created If it is a new file you created and you want to update the project refer to the Updating a Project section earlier in this chapter File Properties Clicking the File Properties button in the SCC Retrieve Files dialog box displays the SCC File Properties dialog box as shown in Figure 11 11 This dialog box gives you a summary of information about the file including the projects it belongs to the checkout status and modification dates Figure 11 11 SCC File Properties Dialog Box You can get more information about a file including a file history by selecting Project Source Code Control Advanced Chapter 11 Source Code Control Tools Professional G Developers Tools Reference Manual 11 26 National Instruments Corporation Checking Out Files When you want to modify a file first check out the file to reserve it so nobody else can modify the file When you check out a file if t
89. al settings on the connector pane K Put default values in parentheses after input names K Include unit information in names if applicable for example Time Limit 10 Seconds K Write descriptions for controls including array cluster and refnum elements Remember that you might need to change the description if you copy the control Chapter 7 Using Consistent Style The G Style Guide Professional G Developers Tools Reference Manual 7 28 National Instruments Corporation K Arrange controls logically For top level VIs put the most important controls in the most prominent positions For subVIs put inputs on the left and outputs on the right and follow connector arrangement K Arrange controls attractively using the Align Objects and the Distribute Objects drop down menus K Do not overlap controls K Use color logically and sparingly if at all K Use error in error out clusters where appropriate K Consider other common thread controls such as taskID refnum and name K Provide a Stop button if necessary Do not use the Abort button to stop a VI Hide the Abort button K Use rings and enumerations where appropriate If you are using a Boolean for two options consider using an enumeration instead to allow for future expansion of options K Use Custom Controls or TypeDefs for common controls especially for rings and enumerations Include it with VIs K In control VIs label controls with the
90. anel instead Include the instruction string on its own front panel that pops up when the user clicks on the Help button Use the Window Options in VI Setup to configure this help panel as either a dialog box that requires the user to click an OK button to close it and continue or as a window the user can move anywhere and close anytime Alternatively you can use this Help button to open an entry in an online help file You can use the Help functions from the Functions Application Control Help palette to open the LabVIEW or BridgeVIEW Help window or to open a help file and link to a specific topic Chapter 6 Creating Documentation Professional G Developers Tools Reference Manual 6 6 National Instruments Corporation Control and Indicator Descriptions Include a description for every control and indicator You can enter this with the Data Operations Description pop up menu item The Help window displays an object description when the user moves the mouse cursor over the object When confronted with a new VI a user has no alternative but to guess the function of each control and indicator unless you include a description Always remember to enter a description as soon as you create the object Then if you copy the object to another VI the description is copied also Also be sure to tell users about this feature Every control and indicator needs a description that includes the following information Functionality
91. anges made by other users do not affect your work until you retrieve them select Project Source Code Control Retrieve Files and retrieve the files you want to freeze When you select Retrieve Files G indicates if the files in your view are out of date and if retrieving files will update your view by showing a snapshot of the latest versions of those files Local Work Directory The local work directory you set in the SCC Local Configuration dialog box is the directory where you store all your work The idea of the work directory is that all users will have the same set of subdirectories and files within that directory As you change files within your directory and check them in to Source Code Control other users can copy the files from Source Code Control to their own work directory The exact location for the work directory is completely up to you unless you are using ClearCase You should make sure you have enough disk Chapter 11 Source Code Control Tools National Instruments Corporation 11 17 Professional G Developers Tools Reference Manual space on the drive that contains that directory because it needs to be able to contain all the files you work on that are under Source Code Control Platform Drop Down Menu You select the platform you are working with in the Platform drop down menu in the SCC Local Configuration dialog box Unless your administrator has changed the setup the G SCC tools should correctly detect the
92. any CINs K Save with the most important or the first frame of structures showing K Review for efficiency especially data copying and accuracy especially parts without data dependency Part II Professional Development Tools This section of the manual describes the features of the tools Chapter 8 VI Metrics Tool describes how to use the VI Metrics tool to measure the complexity of your application Chapter 9 Documentation Tool describes how to create documentation for VIs in HTML or Rich Text Format RTF to create source material for online help files or to print the material directly to a printer Chapter 10 VI Comparison Tools describes the VI Comparison tools which you can use to manage different versions of VIs as you develop large applications Chapter 11 Source Code Control Tools describes the G Source Code Control SCC tools which allow you to add files to SCC and access those files from within the LabVIEW or BridgeVIEW environment National Instruments Corporation 8 1 Professional G Developers Tools Reference Manual 8 VI Metrics Tool This chapter describes how to use the VI Metrics tool to measure the complexity of your application The VI Metrics tool provides a way to measure the complexity of an application similar to the widely used source lines of code SLOC metrics for textual languages With the VI Metrics tool you can view statistics about VIs which can be use
93. archy by breaking the problem into logical pieces The flowchart in Figure 4 1 shows several major blocks you can expect to see in one form or another in every data acquisition system Figure 4 1 Flowchart of a Data Acquisition System Think about the data structures you will need asking questions such as What information needs to accompany the raw data values from the Read Data VI to the Save Data VI This might imply a cluster array which is an array of many channels each element of which is a cluster that contains the value the channel name scale factors and so on A method that performs some action on such a data structure is called an algorithm Algorithms and data structures are intertwined This is reflected in modern structured programming and it works well in G If you like to use pseudocode try that technique as well Figures 4 2 and 4 3 show a relationship between pseudocode and G structures Config Hardware Setup File Setup Read Data Main File I O Handler Hardware Drivers Process Data Save Data Chapter 4 Prototyping and Design Techniques National Instruments Corporation 4 5 Professional G Developers Tools Reference Manual Figure 4 2 Mapping Pseudocode into a G Data Structure Figure 4 3 Mapping Pseudocode into Actual G Code Notice that the program and the data structure correspond Many experienced LabVIEW and BridgeVIEW users prefer to use G sketches You can draw caricatures
94. asier to use than an array index node A block diagram that consists of 50 nested loops is much more difficult to understand than 50 icons connected together in a line Size based metrics rely on a solid base of information that associates productivity with various projects To be accurate you should have statistics for each member of a team because the experience level of team members varies Despite these problems size metrics are used widely for estimating projects A good technique is to estimate a project using size metrics in conjunction with one of the other methods described later in this chapter The two different methods can complement each other If you find differences between the two estimates analyze the assumptions in each to determine the source of the discrepancy Effort Estimation Effort estimation is similar in many ways to number of nodes estimation You break down the project into components that can be more easily estimated A good guideline is to break the project into tasks that take no more than a week to complete More complicated tasks are difficult to estimate accurately Once you have broken down the project into tasks you can estimate the time to complete each task and add the results to calculate an overall cost Chapter 5 Scheduling and Project Tracking National Instruments Corporation 5 5 Professional G Developers Tools Reference Manual Wideband Delphi Estimation You can use wideband d
95. be broken on that platform In this case you might prefer to have the file treated as platform specific so that it is not normally retrieved on unsupported platforms If you write any VIs that contain CINs you need a different version of the VI for each platform because CINs contain code compiled with platform specific compilers If your application uses DLLs the libraries apply only to specific platforms The VIs that call the libraries are platform independent assuming you have a corresponding library for each platform Chapter 11 Source Code Control Tools Professional G Developers Tools Reference Manual 11 38 National Instruments Corporation The G Source Code Control tools give you the flexibility of marking files as platform specific and creating variants for different platforms Platform Specific Files You can mark a file as platform specific by selecting Project Source Code Control Project to display the SCC Project dialog box Select a project that contains the file you want to modify and click the Edit Project button to display the SCC Edit Project File List dialog box Click the Platforms button to display the SCC Edit File Platforms dialog box as shown in Figure 11 17 This dialog box lets you mark the platforms for which a file is available Figure 11 17 SCC Edit File Platforms Dialog Box The platforms selected in the list on the right determine the platforms the file is available on Each
96. because users usually want specific error handling methods For example if an I O VI in your block diagram times out you might or might not want your entire program to halt You also might want the VI to retry for a certain period of time In BridgeVIEW and LabVIEW you make error handling decisions Chapter 7 Using Consistent Style The G Style Guide Professional G Developers Tools Reference Manual 7 22 National Instruments Corporation The following list describes three situations in which errors frequently occur Incorrect initialization of communication or data that has been improperly written to your external device Broken or improperly working external device or loss of power Incorrect file permissions or a lack of disk space When an error occurs you might not want certain subsequent operations to take place For instance if an analog output operation fails because you specify the wrong device you might not want BridgeVIEW or LabVIEW to perform a subsequent analog input operation One method for managing such a problem is to test for errors after every function and put subsequent functions inside Case Structures This can complicate your diagrams and can ultimately hide the purpose of your application An alternative approach which has been used successfully in a number of applications and many of the VI libraries is to incorporate error handling in the subVIs that perform I O Each VI can have an erro
97. ber of VIs they call and the complexity of those vi lib VIs are not added to the total measurements for the selected hierarchy This is appropriate if you are trying to get a measurement of the complexity of the code you have written You can turn off the Exclude vi lib files from statistics option if you want to gather statistics on vi lib VIs as well Saving Metric Information You can save the metric information for a VI hierarchy to a text file by clicking on the Save button in the VI Metrics dialog box Only the columns that are displayed are saved The information at the top of the dialog box that concerns the number of user VIs and the number of library VIs also is saved to the file The information is saved in a tab delimited format so you can easily read it into a spreadsheet or read and parse it using VIs National Instruments Corporation 9 1 Professional G Developers Tools Reference Manual 9 Documentation Tool You can use the Documentation tool to create documentation for VIs in HTML or Rich Text Format RTF to create source material for online help files or to print the material directly to a printer You can use the File Print Documentation command to create documentation for a single VI by printing it directly to a printer or by creating source material for online help Web pages or word processors You can use the Project Documentation Tool command to create documentation for all the VIs in your applica
98. book is written by a developer from Microsoft and contains numerous real world stories that help bring problems and solutions into focus Software Engineering A Practitioner s Approach Roger S Pressman McGraw Hill Inc 1992 ISBN 0 07 050814 3 A detailed survey of software engineering techniques with descriptions of estimation techniques testing approaches and quality control techniques Handbook of Walkthroughs Inspections and Technical Reviews Evaluating Programs Projects and Products Daniel P Freedman and Gerald M Weinberg Dorset House Publishing Co Inc 1990 ISBN 9 932633 19 6 An excellent down to earth discussion of how to conduct design and code reviews with many examples of things to look for and the best practices to follow during a review ISO 9000 3 A Tool for Software Product and Process Improvement Raymond Kehoe and Alka Jarvis Springer Verlag New York Inc 1996 ISBN 0 387 94568 7 Describes what is expected by ISO 9001 in conjunction with ISO 9000 3 and provides templates for documentation Software Engineering Economics Barry W Boehm Prentice Hall 1981 ISBN 0 13 822122 7 Description of the wideband delphi and COCOMO estimation techniques Software Engineering Edited by Merlin Dorfman and Richard Thayer IEEE Computer Science Press 1996 ISBN 0 8186 7609 4 Collection of articles on a variety of software engineering topics including a discussion of the spiral lifecycle model by Barry W Boe
99. cates the steps in the comparison algorithm not the number of differences left to find When the comparison is complete the front panels and block diagrams of the two VIs are displayed in the Differences window as shown in Figure 10 2 Comparison Issues Because G cannot load two VIs with the same name you must rename your VIs to compare them When the Compare VI Hierarchies tool compares two VIs the first VI loads as is and the second VI is moved to the temporary directory with a cmp prefix When using the Compare VIs tool you must rename the appropriate VI to load the two VIs into memory However renaming the VIs does not affect the name of subVIs Because the Compare VI Hierarchies tool does not rename the subVIs the renamed VI will link to the subVIs loaded by the first VI Chapter 10 VI Comparison Tools National Instruments Corporation 10 7 Professional G Developers Tools Reference Manual Source Code Control Compare Files You can use the Source Code Control Compare Files command to compare files from projects under Source Code Control with the local versions of those files To compare VIs under SCC select Project Source Code Control Compare Files You can use the SCC Compare Files dialog box shown in Figure 10 6 to compare the project files on the master directory with the project files on the local directory Figure 10 6 SCC Compare Files Dialog Box After you select a project the SCC Compare Files
100. ced Features section in Chapter 11 Source Code Control Tools for more information Print Documentation dialog box With this dialog box you can create printouts of the front panel block diagram connector pane and description of a VI It also prints the names and descriptions of controls and indicators for the VI and the names and paths of any subVIs You can print this information generate Web pages create online help source files or create word processor documents Documentation tool With this tool you can automate the process of printing documentation for the VIs in your VI hierarchy Refer to Chapter 9 Documentation Tool for more information Developing User Documentation The format of user documentation depends on the type of product you create Documentation for a Library of SubVIs If the software you are creating is a library of subVIs for use by other developers such as an instrument driver or add on package you should create documents with a format similar to the LabVIEW Function and VI Reference Manual LabVIEW users or Appendix A HMI Function Reference in the BridgeVIEW User Manual BridgeVIEW users Because the audience is other developers you can assume they have a working knowledge of LabVIEW or BridgeVIEW Your documentation might Chapter 6 Creating Documentation National Instruments Corporation 6 3 Professional G Developers Tools Reference Manual consist of an overview of the conten
101. ck diagram that uses those blocks For each block create a new stub VI which is a non functional prototype that represents a future subVI Create an icon for this stub VI and create a front panel with the necessary inputs and outputs You do not have to create a block diagram for this VI yet Instead define the interface and see if this stub VI is a useful part of your top level block diagram After you assemble a group of these stub VIs determine the function of each block and how it works Ask yourself whether any given block generates information that some subsequent VI needs If so make sure your top level block diagram sketch contains wires to pass the data between the VIs You can document the functionality of the VI and the inputs and outputs using the Info VI and Description tools in LabVIEW and BridgeVIEW Chapter 4 Prototyping and Design Techniques National Instruments Corporation 4 3 Professional G Developers Tools Reference Manual In analyzing the transfer of data from one block to another try to avoid global variables because they hide the data dependency between VIs and might introduce race conditions Refer to Chapter 28 Performance Issues of the G Programming Reference Manual for more information As your system becomes larger it becomes difficult to debug if you use global variables as your method of transferring information between VIs Continue to refine your design by breaking down each of the component block
102. cking describes techniques for estimating development time and using those estimates to create schedules Chapter 6 Creating Documentation describes techniques for documenting your software Chapter 7 Using Consistent Style The G Style Guide describes recommended practices for good programming technique and style About This Manual Professional G Developers Tools Reference Manual xiv National Instruments Corporation Part II Professional Development Tools Chapter 8 VI Metrics Tool describes how to use the VI Metrics tool to measure the complexity of your application Chapter 9 Documentation Tool describes to create documentation for VIs in HTML or Rich Text Format RTF to create source material for online help files or to print the material directly to a printer Chapter 10 VI Comparison Tools describes the VI Comparison tools which you can use to manage different versions of VIs as you develop large applications Chapter 11 Source Code Control Tools describes the G Source Code Control SCC tools which allow you to add files to SCC and access those files from within the LabVIEW or BridgeVIEW environment Appendices Glossary and Index Appendix A References provides a list of references for further information about software engineering concepts Appendix B Customer Communication contains forms you can use to request help from National Instruments or to comme
103. conferences to attend holidays reports to write existing projects to maintain and other tasks that make up a standard work week Accurate estimates are difficult because of the imprecise nature of most software projects In the initial phase of a project complete requirements are not known The way you will implement those requirements is even less clear As you clarify the objectives and implementation plans you can make more realistic estimates The following sections outline some of the current best practice estimation techniques in software engineering All these techniques require breaking the project down into more manageable components you can estimate individually There are other methods of estimating development time Refer to Appendix A References for a list of documents that describe these and other estimation techniques in more detail Source Lines of Code Number of Nodes Estimation Software engineering documentation frequently refers to source lines of code SLOC as a measurement or metric of software complexity SLOC as a measurement of complexity is popular in part because the information is easy to gather Numerous programs exist for analyzing textual programming languages to measure complexity In general SLOC Chapter 5 Scheduling and Project Tracking National Instruments Corporation 5 3 Professional G Developers Tools Reference Manual measurements include every line of source code developed for a project
104. ct Source Code Control Advanced You have a set of options for deciding how files are locked for each user Locking prevents users from accidentally modifying files without first checking them out The Administer Builtin System dialog box gives you the following options File System Locking For many sites this is the appropriate selection With File System Locking as you check files in they are marked as read only in the file system As you check them out they are changed to read write This works well for most developers Internal Locking With this option as you check files in they are locked by LabVIEW or BridgeVIEW If you open the Show VI Info dialog box you will see that the lock option is turned on When you check files out they are automatically unlocked This is the best choice for multiplatform development for example Windows Macintosh and or UNIX development When you bring a VI from another platform it must be recompiled and saved With internal locking you can actually save the VI The internal locking just prevents you from making edits to a VI The SCC tools can distinguish between real changes and simple modifications such as a recompile that occurs when you load the VI Visual SourceSafe With Visual SourceSafe it is important that you first install Visual SourceSafe on a server and then use the Visual SourceSafe administration tool to add user accounts for each user After you install Visual So
105. d the evolution of your software It also is extremely helpful if you need to determine which version introduced a problem If you want to view a summary of transactions for multiple files click the System History button instead of the File History button in the SCC Advanced dialog box Refer to the following System History section for more information If you use the report generation feature of the SCC Advanced dialog box you can save the system and file histories for files in a project Refer to the Creating Reports section later in this chapter for more information System History The SCC View System History dialog box lets you view a brief summary of transactions that affect the Source Code Control system It lists any transaction that modified the contents of projects created or deleted files or checked in files As with the SCC View File History dialog box the SCC View System History dialog box appearance depends on the Source Code Control system you use either the built in system or a third party system At a minimum it lets you scroll through a listing of transactions In addition most systems allow you to label the current version of all files in projects so they are easier to recognize if you later want to retrieve them For example you might apply a beta label to all files in a project or multiple projects so you can easily retrieve those versions later Refer to the Labeling Versions of Files for Easy Retrieval section
106. developers continue on the same schedule assuming they will be able to work harder and make up the time Instead if you miss a milestone you should evaluate the reasons you missed it Is there a systematic problem that could affect subsequent milestones Is the specification still changing Are quality problems slowing down new development Is the development team at risk of burning out from too much overtime Consider problems carefully Discuss each problem or setback and have the entire team make suggestions on how to get back on track Avoid accusations You might have to stop development and return to design for a period of time You might decide to cut back on certain features stop adding new features until all the bugs are fixed or renegotiate the schedule Deal with problems as they arise and monitor progress to avoid repeating mistakes or making new ones Do not wait until the end of the milestone or the end of the project to correct problems Missing a milestone should not come as a complete surprise Schedule delays do not occur all at once They happen little by little day by day Correct problems as they arise If you do not realize you are behind schedule until the last 2 months of a year long project you probably will not be able to get back on schedule National Instruments Corporation 6 1 Professional G Developers Tools Reference Manual 6 Creating Documentation This chapter describes techniques for documenting
107. dialog box displays all changed files between the master copy and local copy You then can use the Compare Files button to compare the changed files Only VI files are compared Other external files are not compared This tool is similar to the Project Compare VI Hierarchies tool Refer to the Compare VIs section for more information National Instruments Corporation 11 1 Professional G Developers Tools Reference Manual 11 Source Code Control Tools This chapter describes the G Source Code Control SCC tools The SCC tools accessible from the Project Source Code Control menu let you add files to SCC and access those files from within the LabVIEW or BridgeVIEW environment General Source Code Control Concepts Source Code Control tools help significantly in managing projects by allowing you to share files among multiple developers and multiple projects SCC tools maintain a centralized master copy of project files As you make changes you update the master copy to reflect those changes This makes it easy for any developer to access the latest version of the project files Also it encourages code reuse by making all code easily accessible SCC tools also help improve security and quality When a developer decides to modify a file he or she checks out the file marking it so other developers cannot modify the same file at the same time accidentally When he or she completes his or her changes to the file the developer checks
108. e basic reports that describe file transactions and information about the projects maintained under Source Code Control These reports are saved to a text file that you can edit or print using a word processor The options in the SCC Reports dialog box depend on the SCC system you use Chapter 11 Source Code Control Tools National Instruments Corporation 11 35 Professional G Developers Tools Reference Manual Built In System If you use the built in system you get the dialog box shown in Figure 11 16 Figure 11 16 SCC Reports Dialog Box for Built in SCC System The System file listing option describes all files maintained in Source Code Control It lists the current file version and the projects that those files belong to for each file The Summary of system transactions option gives the same information as in the SCC View System History dialog box It lists all check outs and check ins project creations file creations and file deletions It includes the username the date and a brief summary of the changes for each transaction The Project file listing option lists only the files that are members of the selected project The File histories option lists the same information as in the SCC View File History dialog box for each file in the selected project It lists information about when the file was first added to Source Code Control and all information about subsequent changes to the file including the username the date
109. e Code Control Administration that he or she uses to set up the SCC system so others can use it The administrator uses the SCC Administration dialog box as shown in Figure 11 2 to select and configure the SCC system the G SCC tools use for maintaining files The drop down menu lets him or her choose from the built in system or from other supported third party systems Refer to the Selecting the Source Code Control System section earlier in this chapter for information on the differences among these options Figure 11 2 SCC Administration Dialog Box Configuring the SCC System The following sections describe how to configure the built in SCC system Microsoft Visual SourceSafe for Windows 95 NT and ClearCase for Solaris 2 Chapter 11 Source Code Control Tools Professional G Developers Tools Reference Manual 11 8 National Instruments Corporation Built In System If you select the built in system the Administer Builtin System dialog box as shown in Figure 11 3 allows you to configure systemwide options that affect all users If you need to change one of these settings later click the Configure button in the SCC Administration dialog box Figure 11 3 Administer Builtin System Dialog Box You must select a master directory which is where the Source Code Control tools store the files you add to SCC Its important that all users have access to this directory If you want users to be able to modify files they need to
110. e SCC Edit Platform List dialog box as shown in Figure 11 4 Figure 11 4 SCC Edit Platform List Dialog Box This dialog box contains a list of the platforms users can select from when they perform local configuration In general most users should not change any of the options in this dialog box Each entry consists of a long name and an abbreviation The user sees long names when performing local configuration and if he or she chooses to mark a file as platform specific The abbreviation is used in file lists such as in the SCC Advanced dialog box The main reason you might want to edit this list is if LabVIEW or BridgeVIEW becomes available for a new platform In that case you can add the name to the list and immediately be able to support it In general it is probably a good idea to not modify this list even if you initially need to support only a single platform Assuming you do not change any existing items the G SCC tools automatically detect the platform being used If you delete one of the existing platforms and you later decide you want to add support for that platform you must add that Chapter 11 Source Code Control Tools Professional G Developers Tools Reference Manual 11 14 National Instruments Corporation name back in exactly as it was spelled originally to have the auto detection feature work correctly The list is limited to 32 entries Do not change the order after you have added files because each file reme
111. e many things you can do to optimize memory usage and execution time of your G program Generally an advanced topic optimization quickly becomes a concern when your program has large arrays and or critical timing problems Refer to Chapter 28 Performance Issues in the G Programming Reference Manual for more information on optimizing G programs Chapter 7 Using Consistent Style The G Style Guide National Instruments Corporation 7 25 Professional G Developers Tools Reference Manual Code Interface Nodes A Code Interface Node CIN can obscure the function of your VIs Use CINs only when absolutely necessary Include the following information to help your users understand what your CIN does and how to rebuild it CIN Description Contents In the Description pop up menu item of a CIN or in a scrolling label next to the node record the following information Source code filename Platform and operating system Compiler and version Location of source code What the code does List of other files required to build the CIN Other critical information required to maintain the CIN CIN Source Code You should enter the same kind of information in the header file with the source code that you enter in the Description pop up menu item of a CIN If the source code is not too long paste it into a scrollable block diagram string constant Chapter 7 Using Consistent Style The G Style Guide
112. ectories to distinguish the top level VIs from the subVIs You can break the subVIs into multiple LLBs without making the top level structure too confusing Front Panels with Style Consider the following analogy The front panel of a VI is to a G program what the cockpit is to an airplane Just as cockpit instruments give the pilot control over even the most technologically complex aircraft G front panel instruments give you the programmer control over program input and output No conventional programming environment has anything comparable to a LabVIEW or BridgeVIEW built in user interface A user s first contact with your work and with LabVIEW or BridgeVIEW is the front panel so it had better be high quality Consistency Even if you decide not to follow these guidelines at least be consistent The user cannot adapt to your style if your application contains significant changes with every front panel While stylized fonts and garish colors are eye catching they can distract the user Standardize on a few colors fonts and layout practices that are attractive and functional Professional societies have written standards for human machine interface design Chapter 7 Using Consistent Style The G Style Guide National Instruments Corporation 7 5 Professional G Developers Tools Reference Manual Text Do not be tempted to use all the fonts and styles available Stick to three standard fonts application system and dialog
113. ed information call 512 795 6990 You can access these services at United States 512 794 5422 Up to 14 400 baud 8 data bits 1 stop bit no parity United Kingdom 01635 551422 Up to 9 600 baud 8 data bits 1 stop bit no parity France 01 48 65 15 59 Up to 9 600 baud 8 data bits 1 stop bit no parity FTP Support To access our FTP site log on to our Internet host ftp natinst com as anonymous and use your Internet address such as joesmith anywhere com as your password The support files and documents are located in the support directories Professional G Developers Tools Reference Manual B 2 National Instruments Corporation Fax on Demand Support Fax on Demand is a 24 hour information retrieval system containing a library of documents on a wide range of technical information You can access Fax on Demand from a touch tone telephone at 512 418 1111 E Mail Support Currently USA Only You can submit technical support questions to the applications engineering team through e mail at the Internet address listed below Remember to include your name address and phone number so we can contact you with solutions and suggestions support natinst com Telephone and Fax Support National Instruments has branch offices all over the world Use the list below to find the technical support number for your country If there is no National Instruments office in your country contact the source from which you purchased your software to
114. ed to enter a summary of the changes made This summary information is added to the log for that file You can view the history information for a file or for the system and generate reports that contain that information Refer to the SCC File History System History and Creating Reports sections of Chapter 11 Source Code Control Tools for more information In addition if you back up your project at specific checkpoints you can use the VI Comparison tools to compare the latest version of a project with another version to verify the changes in your project Refer to Chapter 10 VI Comparison Tools for more information Change Control Large projects might require a formal process for evaluation and approval of each change request A formal evaluation system like this might be too restrictive so be selective when choosing the control mechanisms you introduce into your system Changes to specific components such as documents related to user requirements must be dealt with cautiously because they generally are worked out through several iterations with the customer In this case the word customer is used in a general sense You might be your own customer Chapter 3 Incorporating Quality into the Development Process National Instruments Corporation 3 5 Professional G Developers Tools Reference Manual other departments in your company might be your target audience or you might develop the software under contract for a third part
115. elopers Tools Reference Manual 5 Scheduling and Project Tracking This chapter describes techniques for estimating development time and using those estimates to create schedules This chapter also distinguishes between an estimate which reflects the time required to implement a feature and a schedule which reflects how you fulfill that feature Estimates are commonly expressed in ideal person days or 8 hours of work In creating a schedule from estimates you must consider dependencies one project might have to be completed before another can begin and other tasks such as meetings support for existing projects and so on Estimation One of the principal tasks of planning is to estimate the size of the project and fit it into the schedule because most projects are at least partially driven by a schedule Schedule resources and critical requirements interact to determine what you can implement in a release Unfortunately when it comes to estimating software schedules accurately few people are successful Major companies have had software projects exceed original estimates by a year or more Poor planning or an incomplete idea of project goals often causes deadlines to be missed Another major cause of missed schedules is feature creep Your design gradually grows to include features that were not part of the original requirements In many cases the delays in schedule are a result of using a code and fix development process rather
116. elphi estimation in conjunction with any of the other estimation techniques this chapter describes to achieve more reliable estimates For successful wideband delphi estimation multiple developers must contribute to the estimation process First divide the project into separate tasks Then meet with other developers to explain the list of tasks Avoid discussing time estimates during this early discussion Once you have agreed on a set of tasks each developer separately estimates the time it will take to complete each task using uninterrupted person days as the unit of estimation The developers should list any assumptions made in forming their estimates The group then reconvenes to graph the overall estimates as a range of values It is a good idea to keep the estimates anonymous and to have a person outside the development team lead this meeting After graphing the original set of values each developer reports any assumptions made in determining the estimate For example one developer might have assumed a certain VI project takes advantage of existing libraries Another developer might point out that a specific VI is more complicated than expected because it involves communicating with another application or a shared library Another team member might be aware of a task that involves an extensive amount of documentation and testing After stating assumptions each developer reexamines and adjusts the estimates The group then graphs and di
117. empt to modify the same local variable resulting in the loss of data Refer to Chapter 28 Performance Chapter 7 Using Consistent Style The G Style Guide National Instruments Corporation 7 13 Professional G Developers Tools Reference Manual Issues of the G Programming Reference Manual for more information about using local variables VI Setup To access the VI Setup dialog box pop up on the VI icon and choose VI Setup Think about the window behavior and style of every VI in your project In the Execution Options version of the VI Setup dialog box select Show Front Panel When Loaded and Close Afterwards if Originally Closed for front panels you want to appear and disappear automatically Do not set higher priority than the default on any VI without giving it some serious thought A high priority VI that loops forever will block execution of all other VIs Refer to Chapter 26 Understanding the G Execution System of the G Programming Reference Manual for information on how priorities work In the Window Options version of the VI Setup dialog box select Dialog Box for front panels that should wait for input from the user before the program can continue Turn off the Allow User to Close Window option to keep users from accidentally closing an important front panel while it is running Disable the scroll bars the menu bar and the toolbar unless the user needs them You can use the keyboard shortcuts for cut copy and paste even
118. ensures that it is not automatically deleted as it gets older One of the administrator options for the built in system is to specify how many older versions of a file to maintain Labeled versions of a file are not deleted unless you delete them yourself either from the SCC File History dialog box or from the SCC Advanced dialog box If you use a third party SCC system you probably have the option of labeling files as well but you might have to do it using the SCC tools that company provides Also notice that with third party tools the way in which previous versions are maintained and when they get deleted is configured using the tools provided with the third party SCC system If you use the built in SCC system and you need to label multiple files you can use the SCC View File History dialog box on each one but that can be tedious Instead if you want to take a snapshot of all the files in a project and apply the same label to all the files use the SCC View System History dialog box It has an option that lets you label all files in a project with the same label It also has an option for retrieving files with the same label Creating Reports An important feature of any SCC tool is the ability to generate reports that describe system and file activity because SCC tools should help you not only to maintain files but also to track the changes that happen to those files The Reports button in the SCC Advanced dialog box lets you creat
119. equirements Because you can add and remove controls quickly especially if you avoid developing block diagrams you can help customers clarify their requirements Chapter 2 Development Models National Instruments Corporation 2 9 Professional G Developers Tools Reference Manual Spiral Model The spiral model is a popular alternative to the waterfall model It emphasizes risk management so you find major problems earlier in the development cycle In the waterfall model you have to complete the design before you begin coding With the spiral model you break up the project into a set of risks that need to be dealt with You then begin a series of iterations in which you analyze the most important risk evaluate options for resolving the risk deal with the risk assess the results and plan for the next iteration Figure 2 2 illustrates the spiral lifecycle model Figure 2 2 Spiral Lifecycle Model Risks are any issues that are not clearly defined or have the potential to affect the project adversely For each risk you need to consider two things How likely it is to occur probability and the severity of its effect on the project loss You might use a scale of 1 to 10 for each of these items with 1 representing the lowest and 10 representing the highest Your risk exposure is the product of these two rankings Cumulative Cost Evaluate Alternatives and Risks Determine Objectives Alternatives and Constraints Develop and Te
120. er Communication National Instruments wants to receive your comments on our products and manuals We are interested in the applications you develop with our products and we want to help if you have problems with them To make it easy for you to contact us this manual contains comment and configuration forms for you to complete These forms are in Appendix B Customer Communication at the end of this manual National Instruments Corporation 1 1 Professional G Developers Tools Reference Manual 1 Introduction This chapter introduces you to the features of the Professional G Developers Tools Required System Configuration These tools are available for all platforms except Windows 3 1 Windows 3 1 is not supported because the Source Code Control SCC tools require that virtual instruments VIs be stored in individual files rather than in libraries LLBs You can use the File Manager tool to convert LLBs to directories Note Although you cannot use these tools under Windows 3 1 you still can develop for customers who need Windows 3 1 support You can use Windows 95 NT as the development platform and save VIs as individual files When you need to send software to a Windows 3 1 user save VIs in LLBs Configuration For installation instructions refer to the Professional G Developers Tools Release Notes After installation is complete the administrator must set up the Source Code Control system for the other users All users
121. erence Manual for more information Reduce the number of pivot points in wires by aligning the source and destination of the wires Use the cursor keys to remove single pixel kinks from wires Delete excess wires such as loops Evenly space parallel wires in straight lines and around corners Notice object alignment consistent spacing and labels on the long wires illustrated in Figure 7 9 Figure 7 9 Good Wiring in a Simple Block Diagram Chapter 7 Using Consistent Style The G Style Guide Professional G Developers Tools Reference Manual 7 18 National Instruments Corporation Labeling Give major structures in the block diagram names and descriptions through the Description pop up menu item This helps the user understand complex segments of code Use enumerations as inputs to Case Structures when possible because the names from the enumerations appear at the top of Case Structures instead of numbers Add comments to explain the purpose of each frame For comments choose a font size and style that will stand out Always label constants because they are not self explanatory Show the label of a subVI if the icon does not describe the function of the VI sufficiently Use free labels on long stretches of wire to label the signal data Place the label right on top of the wire with a transparent border as shown in the following example Paste long comments into small string constants and make them scrollable
122. es 11 28 to 11 29 checking out files 11 26 to 11 27 deleting files from SCC 11 31 Edit Change Comments dialog box 11 29 file properties 11 25 file status 11 24 to 11 25 History window for documenting changes 11 27 labeling versions of files for easy retrieval 11 34 Index Professional G Developers Tools Reference Manual I 4 National Instruments Corporation managing project related files 3 3 previous versions of files 3 3 to 3 4 11 33 retrieving files 11 23 to 11 25 SCC Check Files In dialog box 11 28 SCC Check Files Out dialog box 11 26 SCC File Properties dialog box 11 25 SCC Retrieve Files dialog box 11 24 SCC user name 11 29 to 11 30 tracking changes 3 4 filenames directories VI libraries and VIs 7 2 limitations on various platforms 11 36 to 11 39 fonts style guidelines 7 5 Food and Drug Administration FDA standards 3 14 front panels self documenting 6 5 style checklist 7 27 to 7 28 style considerations 7 4 to 7 8 color 7 5 to 7 6 consistency 7 4 graphics and custom controls 7 6 to 7 8 layout 7 7 sizing and positioning 7 7 to 7 8 text 7 5 FTP support B 1 function point estimation 5 6 G G Developers Tools See Professional G Developers Tools G style guide See style guidelines globals locals statistics 8 4 graphics and custom controls 7 6 to 7 7 H help files creating 6 4 help compilers 6 4 using Document tool 9 2 linking to VIs 6 4 hierarchical organization
123. eting Files from SCC 11 31 SCC File History 11 31 System History 11 32 Accessing Previous Versions of Files 11 33 Built In System 11 33 Third Party Systems 11 33 Labeling Versions of Files for Easy Retrieval 11 34 Creating Reports 11 34 Built In System 11 35 Visual SourceSafe 11 35 Multiplatform Issues 11 36 Cross Platform Source Code Control 11 36 Filename Limitations 11 36 Platform Dependent SCC Files
124. eve check out and check in files of a Source Code Control project Retrieving Files To copy files from the master directory to your working directory select Project Source Code Control Retrieve Files Chapter 11 Source Code Control Tools Professional G Developers Tools Reference Manual 11 24 National Instruments Corporation The SCC Retrieve Files dialog box lets you select a project or project group from which to retrieve files as shown in Figure 11 10 Figure 11 10 SCC Retrieve Files Dialog Box To retrieve a file select it and click the Get File s button To retrieve multiple files shift click items to select them and then click the Get File s button Because the list can be long if you have several files in your project you can use the Only list VIs with open panels checkbox to ignore unopened files File Status The SCC Retrieve Files dialog box automatically compares the local copy of files in the project with the master copy the SCC system maintains It categorizes the files into the following categories and indicates this information in parentheses next to each file in the list Local copy has changed If the file is not checked out you should either check out the file or replace the local copy with the version from the server You should not modify local files without first checking them out Server copy has changed This generally means that another developer has modified the VI Loc
125. fferences in the list of files the SCC File Wizard walks you through the process of updating SCC to reflect local changes This wizard first presents a dialog box that summarizes the differences between the local version of your hierarchy and the version that is under SCC This wizard detects whether one hierarchy has files that the other does not and whether files are in different locations in the local hierarchy from the hierarchy under SCC If you choose to edit the project a series of dialog boxes describe these differences in more detail and give you the option to change the project or ignore the difference No changes are made unless you click Save in the final dialog box which summarizes the new list of files Chapter 11 Source Code Control Tools National Instruments Corporation 11 21 Professional G Developers Tools Reference Manual Managing Files with the Same Name In general you should be cautious when working with files with the same name because it is easy to accidentally link the wrong version of a file to a hierarchy The SCC tools detect if you accidentally link the wrong version of a file when you edit a project using the SCC Edit Project File List dialog box You have the choice to avoid changing the project by moving the existing file in SCC to the new location or by adding the new file as file with the same name in a different location Removing Files from a Project To remove files from a project select Project
126. ful in finding areas that are too complex You also can use those statistics to establish baselines for estimating future projects Remember that any metric such as SLOC is a crude measurement of complexity The VI Metrics tool gives you access to several statistics because you might find that some columns are more valuable than others in some cases For example you might decide that for user interface VIs you can combine certain statistics to get a better idea of the complexity of a VI In that case you can make your own metric by saving the information about a VI and writing VIs to parse the results combining fields to produce a new measurement of the complexity of a VI National Instruments is interested in hearing about combined or alternative metrics you find useful in analyzing your VIs You can use the Technical Support form at the back of this manual or the National Instruments Web site located at www natinst com to submit suggestions Chapter 8 VI Metrics Tool Professional G Developers Tools Reference Manual 8 2 National Instruments Corporation Using the VI Metrics Tool To use the tool first open the VI s you want to analyze Select Project VI Metrics The VI Metrics dialog box appears as shown in Figure 8 1 Figure 8 1 VI Metrics Tool Dialog Box Use the drop down menu at the top of the dialog box to select from the list of VIs with open front panels in memory After you select a VI the dialog box updates t
127. g it won t be useful In some cases this might be correct However in most applications developing in stages is a better approach When you analyze the requirements for a project you should prioritize features You might be able to develop an initial system that provides useful functionality in a shorter time at a lower cost Then you can add features incrementally The more you try to accomplish in a single stage the greater the risk of falling behind schedule Releasing software incrementally reduces schedule pressures and ensures timely software release Refer to the Lifecycle Models section later in this chapter for more information If I can just get all the features in within the next month I should be able to fix any problems before the software is released To release high quality products on time you should maintain quality standards throughout development Do not build new features on an unstable foundation and rely on correcting problems later This exacerbates problems and increases cost Although you might complete all the features on time the time required to correct the problems in the existing and the new code can delay the release of the product You should prioritize features and implement the most important ones first Once the most important features are tested thoroughly you can choose to work on lower priority features or defer them to a future release Refer to Chapter 3 Incorporating Quality into
128. g stages you begin to see how everything works together and you might discover you need to adjust requirements Prototyping can be an effective tool for demonstrating how a design might deal with a set of requirements You can build a prototype adjust the requirements and revise the prototype several times until you have a clear picture of your overall objectives In addition to clarifying the requirements the prototype also defines many areas of the design simultaneously The pure waterfall model allows for prototyping in the later architectural design stage and subsequent stages but not in the early requirements stages Chapter 2 Development Models Professional G Developers Tools Reference Manual 2 8 National Instruments Corporation Prototyping has drawbacks however Because it appears that you have a working system quickly customers might expect a complete system sooner than is possible In most cases the prototype is built on compromises that allow it to come together quickly but that could prevent the prototype from being an effective basis for future development You need to decide early whether you will use the prototype as a basis for future development All parties should agree to this decision before development begins You should be careful that prototyping does not become a disguise for a code and fix development cycle Before you begin prototyping you should gather clear requirements and create a design plan Limi
129. ge system do you want to use The SCC tools can manage files or they can integrate with a third party tool Refer to Chapter 11 Source Code Control Tools National Instruments Corporation 11 3 Professional G Developers Tools Reference Manual the following Selecting the Source Code Control System section for more information Will users be developing on multiple platforms or a single platform This decision might help decide the storage system you will use as well as how to configure that system For multiplatform development National Instruments recommends the built in system For single platform development you can use either the built in system or one of the third party SCC tools that are supported Once the system is up and running there is typically not a lot of work involved on the part of the administrator unless you want to change access privileges for files or limit access for specific users If you are using ClearCase refer to the ClearCase section later in this chapter for more information 2 Users configure the SCC tools to access the system The main decision users must make is where they will have a working directory The working directory is a directory on your local system where all VI development takes place As you retrieve files from SCC they are retrieved to this directory and its subdirectories You cannot add files to SCC that are outside of this directory With the built in system it is important
130. guage ___________________________________________________________ Programming language version _____________________________________________________ Other boards in system ____________________________________________________________ Base I O address of other boards ____________________________________________________ DMA channels of other boards _____________________________________________________ Interrupt level of other boards ______________________________________________________ Documentation Comment Form National Instruments encourages you to comment on the documentation supplied with our products This information helps us provide quality products to meet your needs Title Professional G Developers Tools Reference Manual Edition Date May 1998 Part Number 321393B 01 Please comment on the completeness clarity and organization of the manual _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ If you find errors
131. h the instrument command set In most cases you should use a top down design strategy You might mix in some components of bottom up design if necessary Thus in the case of an instrument driver you might use a risk minimization strategy to understand the limitations of the instrument command set and develop the lower level components Then you could use a top down approach to develop the high level blocks The following example shows in more detail how you can apply this technique to the process of designing a driver for a GPIB instrument Instrument Driver Example A complex GPIB controlled instrument can have hundreds of commands many of which interact with each other A bottom up approach might be the most effective way to design a driver for such an instrument The key here is that the problem is detail driven You must learn the command set and design a front panel that is simple for the user yet gives full control of the instrument functionality Design a preliminary VI hierarchy preferably one based on similar instrument drivers You must satisfy the user s needs Designing a driver requires more than putting knobs on GPIB commands The example chosen here is the Tektronix 370A Curve Tracer It has about 100 GPIB commands if you include the read and write versions of each one Once you begin programming the hierarchy will fill out naturally one subVI at a time Add lower level support VIs as required such as a communications
132. handler a routine to parse a complex header message or an error handler For instance the 370A requires a complicated parser for the waveform preamble that contains information such as scale factors offsets sources and units It is much cleaner to bury this operation in a subVI than to let it obscure the function of a higher level VI Also a communications handler makes it simple to exchange messages with the instrument Such a handler formats and sends the message reads the response if required and checks for errors Once the basic functions are ready assemble them into a demonstration driver VI that makes the instrument do something useful You will quickly find any fundamental flaws in your earlier choices of data structures terminal assignments and default values Chapter 4 Prototyping and Design Techniques Professional G Developers Tools Reference Manual 4 8 National Instruments Corporation Chapter 7 Getting Started with a LabVIEW Instrument Driver of the LabVIEW User Manual describes this development process in detail The top level VI in Figure 4 5 is an automated test example It calls nine of the major functions included in the driver package Each function in turn calls subVIs to perform GPIB I O file I O or data conversion Figure 4 5 VI Hierarchy for the Tektronix 370A Designing for Multiple Developers One of the main challenges in the planning stage is to establish discrete project areas for each deve
133. have read write access to this directory As users check files in and out the files are copied to this directory and history information for each file is maintained within this directory Consequently you should make sure that this directory has plenty of available disk space In addition under Windows 95 NT each user should connect to the volume that contains this directory and map that volume as a network drive for example as D rather than as a UNC path of the form machine volume UNC filename support varies slightly between Windows 95 NT Consequently the SCC tools do not support UNC filenames Chapter 11 Source Code Control Tools National Instruments Corporation 11 9 Professional G Developers Tools Reference Manual Use the drop down menu in the center of the Administer Builtin System dialog box to configure how many backups to maintain for files under Source Code Control If you decide to maintain file backups a copy of the old file is created when a user checks in a file You can configure the system so no backups are maintained a specific number is maintained or there is no limit on backups In general it is probably good to maintain a small number of backups so you can retrieve older versions of the files If you choose to have no limits on backups you need to delete old versions periodically to avoid running out of storage space on the server You can monitor the amount of storage used for backups by selecting Proje
134. he SCC View System History dialog boxes The SCC View File History dialog box allows you to retrieve a previous version of a single file The SCC View System History dialog box allows you to scan the system for all versions of a file with a specific label and allows you to retrieve those versions This can be useful in taking a snapshot of your product that you can retrieve easily For example you can label the current version of all files in a project as rel1 for the first release Third Party Systems Most third party systems including Visual SourceSafe and ClearCase for Solaris 2 offer similar features for maintaining previous versions of files and labeling files The option might be configurable Consult the documentation for the third party SCC system to determine the options By default Visual SourceSafe and ClearCase for Solaris 2 maintain history for files Chapter 11 Source Code Control Tools Professional G Developers Tools Reference Manual 11 34 National Instruments Corporation Labeling Versions of Files for Easy Retrieval With the built in SCC system the File History button in the SCC Advanced dialog box lets you retrieve older versions of files By default however the names you see are based on the older version number and the version creation date The SCC View File History dialog box lets you optionally label the current version so it is easier to recognize if you later need to retrieve it Also labeling a file
135. he VI or select File Save As and use the same name Controls and Indicators The following sections guide you on when and how to use various controls and indicators effectively Descriptions Every control and indicator should have a description Refer to the VI and Control Descriptions section in Chapter 6 Creating Documentation for more information Labels The Help window displays labels as part of the connector Label the most important controls and indicators on a front panel in bold Display controls and indicators that are rarely used in square brackets If the default value of a control is valid add it to the name in parentheses Include the units of the value where applicable The Required Recommended Optional setting affects the appearance of the inputs and outputs in the Help window The Connector Panes section later this chapter describes the Required Recommended Optional setting The name of a control or indicator should describe its function For example for a ring or labeled slide with options for volts ohms or amperes a name like Select units for display is better than V O A and is certainly an improvement over the generic Mode Of course long names use valuable space on the block diagram especially if you use any local variables or Bundle Unbundle by Name functions You might prefer to give the control a short name then add an explanatory label to it Chapter 7 Using Consistent Style The G
136. he list at the bottom with the names of the VI and its subVIs plus information on each VI For each VI in the selected hierarchy the dialog box lists the number of nodes that VI contains Nodes are the executable objects on your block diagram They are analogous to statements operators and subroutine calls in conventional programming languages This number gives you a rough metric that is comparable to the SLOC metric commonly used with textual languages The number of nodes includes functions such as Add Subtract and so on subVI calls and structures such as Case While Loop and so on It also includes terminals for front panel objects constants local and global references and attribute nodes Notice that for attribute nodes reading multiple attributes with the same node counts as one node If you want to Chapter 8 VI Metrics Tool National Instruments Corporation 8 3 Professional G Developers Tools Reference Manual know the total number of attributes a VI reads or writes refer to the User Interface Statistics section later in this chapter The number of nodes does not include wires tunnels or objects that are subcomponents of structures such as the loop iteration count of a For Loop or a sequence local As an example the block diagram in Figure 8 2 contains eight nodes three terminals a constant a random number function a multiply a Case Structure and a For Loop Figure 8 2 Block Diagram with Eight Nodes
137. here is a newer version on the server that version is copied to your local system It is then unlocked so you can edit the VI While you have the file checked out nobody else can check out the file or modify it This helps to ensure that only one developer at a time modifies a VI To check out files select Project Source Code Control Check Files Out to display the SCC Check Files Out dialog box as shown in Figure 11 12 The SCC Check Files Out dialog box lets you select a project or project group from which to check out files When you check out a file it is checked out for all projects When you check the file back in the new version is available for all projects that contain the file Figure 11 12 SCC Check Files Out Dialog Box Chapter 11 Source Code Control Tools National Instruments Corporation 11 27 Professional G Developers Tools Reference Manual The interface for checking out files is almost identical to that for retrieving files You cannot check out files that are already checked out to you or to another developer If the file is checked out the list indicates the username of the developer with the VI If you need to check out multiple files shift click items in the listbox to select the files you want to work on and click the Checkout File button In general you should avoid checking out files for long periods of time Instead you should try to make incremental changes to your files When you are sure your f
138. hm National Instruments Corporation B 1 Professional G Developers Tools Reference Manual B Customer Communication For your convenience this appendix contains forms to help you gather the information necessary to help us solve your technical problems and a form you can use to comment on the product documentation When you contact us we need the information on the Technical Support Form and the configuration form if your manual contains one about your system configuration to answer your questions as quickly as possible National Instruments has technical assistance through electronic fax and telephone systems to quickly provide the information you need Our electronic services include a bulletin board service an FTP site a fax on demand system and e mail support If you have a hardware or software problem first try the electronic support systems If the information available on these systems does not answer your questions we offer fax and telephone support through our technical support centers which are staffed by applications engineers Electronic Services Bulletin Board Support National Instruments has BBS and FTP sites dedicated for 24 hour support with a collection of files and documents to answer most common customer questions From these sites you can also download the latest instrument drivers updates and example programs For recorded instructions on how to use the bulletin board and FTP services and for BBS automat
139. icons Because it is in bitmap form text you type in the Icon Editor does not change when viewed on a machine with different fonts The Block Diagram The block diagram concept used in LabVIEW and BridgeVIEW is considered a breakthrough in software engineering Like any new tool developers still are learning optimal methods for its application Fortunately programming in LabVIEW and BridgeVIEW is graphical so you can create programs that are functional and visually engaging This section contains recommendations for improving block diagrams in function and in appearance Chapter 7 Using Consistent Style The G Style Guide National Instruments Corporation 7 17 Professional G Developers Tools Reference Manual Wiring Etiquette Haphazard wiring can distract the user and make block diagrams difficult to follow Align and distribute objects to make a block diagram as neat as possible Employ symmetry and straight lines to make the block diagram easy to read Do not hide objects behind structures or other objects The following are some general wiring tips Avoid routing wires underneath structures or icons and never route wires through an icon to a terminal on the other side of the icon Do not use local variables just to avoid having long wires Every local variable that reads the data makes a copy of it Using local variables can lead to race conditions Refer to Chapter 28 Performance Issues in the G Programming Ref
140. iles are in good shape you should check them in Whenever you check in a file make sure you have tested it thoroughly so you do not cause problems for other developers If you need to modify other VIs before you can check in a specific VI check out the other VIs make the changes and test the VIs before checking in any of the VIs If you need to make several changes to a VI consider checking in the file between modifications and then check the file back out to start the next modification Not only does this allow other developers access to your changes but it also gives you a checkpoint you can return to if you later decide that your subsequent changes were incorrect Use the History Window to Document Changes As you make modifications to a VI select Windows Show History to enter notes about your changes You can check out a file for several days The History window helps you remember the changes you have made When you check the file back in the SCC tools let you enter a description of your changes By default this text is the history text since you checked out the file The more detailed you are in making notes the better off you will be These notes can help if you need to make reports about the changes you have made or if you later need to retrieve an older version and you need to distinguish between two different versions You can create reports and access old versions by selecting Project Source Code Control Advanced
141. in the manual please record the page numbers and describe the errors _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ Thank you for your help Name _________________________________________________________________________ Title __________________________________________________________________________ Company _______________________________________________________________________ Address ________________________________________________________________________ _______________________________________________________________________________ E Mail Address __________________________________________________________________ Phone ___ __________________________ Fax ___ _______________________________ Mail to Technical Publications Fax to Technical Publications National Instruments Corporation National Instruments Corporation 6504 Bridge Point Parkway 512 794 5678 Austin Texas 78730 5039 National Instruments
142. ing methodologies Black Box and White Box Testing The method of black box testing is based on the expected functionality of software without knowledge of how it works It is called black box testing because you cannot see the internal workings Black box testing can be done based largely on a knowledge of the requirements and the interface of a module For a subVI you could perform black box tests on the interface of a subVI to evaluate results for various input values If robustness is a quality goal you should include erroneous input data to see if the subVI deals with it well For example for numeric inputs you should see how the subVI deals with infinity not a number and other out of range values Refer to the Unit Testing section later in this chapter for more examples The method of white box testing is designed with knowledge of the internal workings of the software Use white box testing to check that all the major paths of execution are exercised By examining a block diagram and looking at the conditions of Case Structures and the values controlling loops you can design tests that check those paths White box testing on a large scale is impractical because it is difficult to test all possible paths Although white box testing is difficult to fully implement for large programs you can choose to test the most important or complex paths White box testing can be combined with black box testing for more thorough testing of software
143. inue development If the customer reports a problem you might need to access a copy of the beta version One way to achieve this is to back up your files periodically However unless you back up your system after every change you might not have access to every version Chapter 3 Incorporating Quality into the Development Process Professional G Developers Tools Reference Manual 3 4 National Instruments Corporation The G Source Code Control tools provide a way to check in new versions of a file and make a back up copy of the old version Depending on how you configure the system the tools can maintain multiple backup copies of a file You can use the tools to label versions of files with descriptive names like beta v1 0 and so on You can label any number of files and later retrieve all versions of a file with a specific label When you release a version of your software take a snapshot of the files by attaching a label to them Chapter 11 Source Code Control Tools describes the file and system history options Tracking Changes If you are managing a software project it is important to monitor changes and track progress toward specific milestone objectives You also can use this information to determine problem areas of a project by identifying which components required a lot of changes The G Source Code Control tools maintain a log of all changes made to files and projects When checking in a file the developer is prompt
144. k in files when you are ready to share your changes with others This check out check in system ensures that only one developer modifies a specific VI at a time The G SCC tools are built on an open Application Programming Interface so they can communicate with either a built in SCC system available to all platforms or other third party SCC systems These tools support the built in system Microsoft Visual SourceSafe for Windows 95 NT and Rational Software ClearCase for Solaris 2 Measure complexity The VI Metrics tool provides a simple way to measure the complexity of an application similar to the widely used source lines of code metrics for textual languages With this tool you also can view many other statistics about VIs which are useful in examining your VIs to find overly complex areas or in establishing baselines for estimating future projects Print documentation The Documentation tool makes it easy to print documentation for VIs in your hierarchy In addition to creating printed documentation you can use this tool to create Web pages online help source files and word processor documents for your VIs Compare files VI Comparison tools make it easy to view the differences between two VIs two hierarchies of VIs and between files and files under Source Code Control This is extremely important when multiple developers work on the same set of VIs or when you need to understand how your VIs have changed Part I
145. lems as early as possible and allow time for formal reviews and thorough testing Configuration Management Configuration management is the process of controlling changes and ensuring they are reviewed before they are made Chapter 2 Development Models outlines development models such as the waterfall model A central focus of these models is to convert software development from a chaotic unplanned activity to a controlled process These models improve software development by establishing specific measurable goals at each stage of development Regardless of how well development proceeds changes will need to be implemented Customers might introduce new requirements in the design stage Performance problems discovered during development might prompt reevaluation of the design You might need to rewrite a section of code to correct a problem found in testing Changes can affect any components of the project from the requirements and specification to the design code and tests If these changes are not made carefully you might introduce problems that can delay development or degrade quality Source Code Control After setting the project quality requirements develop a process to deal with changes This is important for projects with multiple developers As the developers work on VIs they need a method for collecting and sharing their work A simple method to deal with this is to establish a central source repository If each of the develo
146. lied to a category breakdown of the project requirements The requirements are analyzed for features such as inputs outputs user inquiries files and external interfaces These features are tallied and each is weighted The results are added to produce a number that represents the complexity of the project You can compare this number to function point estimates of previous projects to determine an estimate Function point estimates were designed primarily with database applications in mind but have been applied to other software areas as well Function point estimation is popular as a rough estimation method because it can be used early in the development process based on requirements documents However the accuracy of function points as an estimation method has not been thoroughly analyzed COCOMO Estimation COCOMO COnstructive COst MOdel is a formula based estimation method for converting software size estimates to estimated development time COCOMO is a set of methods that range from basic to advanced Basic COCOMO makes a rough estimate based on a size estimate and a simple classification of the project type and experience level of a team Advanced COCOMO takes into account reliability requirements hardware features and constraints programming experience in a variety of areas and tools and methods used for developing and managing the project Mapping Estimates to Schedules An estimate of the amount of effort required for a
147. log box that allows you to select the master directory The dialog box verifies the path you specify is valid and has been set up by the administrator for Source Code Control You also can click the Configure button in the SCC Local Configuration dialog box to access this dialog box After you configure the master directory you need to configure the local directory as described in the Local Work Directory section later in this chapter Visual SourceSafe To use Visual SourceSafe relatively little configuration is needed Install Visual SourceSafe and make sure your administrator assigned you an account and password In the SCC Local Configuration dialog box specify the local work directory and the platform as described in the Local Work Directory section later in this chapter ClearCase In addition to providing the correct local directory users must set up a ClearCase view and make sure it is set every time they launch LabVIEW or BridgeVIEW To emulate the model of having local copies of files users must set up unique labels to mark current working versions of files When working under this model users must edit their views to show labeled files before most recent versions Users must take the following steps to configure their ClearCase Source Code Control system 1 Find out the VOB directory name from the administrator s For example vobs vobname 2 Create a view a Set umask typically 2 for shared files Refer to
148. loper As you design the specification and architectural design you should begin to see areas that have a minimal amount of overlap For example a complicated data monitoring system might have one set of VIs to display and manipulate data and another set to acquire the information and transfer it to disk These two modules are substantial do not overlap and can be assigned to different developers Inevitably there will be some interaction between the modules One of the principal objectives of the early design work is to design how those Chapter 4 Prototyping and Design Techniques National Instruments Corporation 4 9 Professional G Developers Tools Reference Manual modules interact with each other The data display system must access the data it needs to display The acquisition component needs to provide this information for the other module At an early stage in development you might design the connector panes of VIs needed to transfer information between the two modules Likewise if there are global data structures that must be shared these should be analyzed and defined early in the architectural design stage before the individual developers begin work on their components In the early stages each developer can create stub VIs with the connector pane interface that was defined for the shared module This stub VI can do nothing or if it is a VI that returns information you could have it generate random data This allows each
149. manuals Include additional pages if necessary Name __________________________________________________________________________ Company _______________________________________________________________________ Address ________________________________________________________________________ _______________________________________________________________________________ Fax ___ ________________Phone ___ __________________________________________ Computer brand____________ Model ___________________Processor _____________________ Operating system include version number ____________________________________________ Clock speed ______MHz RAM _____MB Display adapter __________________________ Mouse ___yes ___no Other adapters installed_______________________________________ Hard disk capacity _____MB Brand_________________________________________________ Instruments used _________________________________________________________________ _______________________________________________________________________________ National Instruments hardware product model _____________ Revision ____________________ Configuration ___________________________________________________________________ National Instruments software product ___________________ Version _____________________ Configuration ___________________________________________________________________ The problem is ______________________________________________________________
150. matical function draw a plot of that function as shown in the following examples For simple data processing functions depict the input and output data types and the nature of the operation This can become cryptic however so use caution The following examples are icons for the 1D Linear Evaluation and Solve Linear Equations VIs Within driver packages maintain a unifying theme for groups of icons Basing your design on drivers for similar instruments makes it easier for Chapter 7 Using Consistent Style The G Style Guide Professional G Developers Tools Reference Manual 7 16 National Instruments Corporation users to convert from one instrument to another with minimal confusion The following examples are icons for the HP 54570 instrument driver Do not spoil the international language of pictures by creating an icon that is a play on English words For example do not represent a datalogging VI with a picture of a lumberjack Icons for higher level VIs might require some artistic talent The following icons are examples of good icons The Icon Editor offers useful tools for creating icons For example to make symbols for the various inputs and outputs on the icon you can display the connector pattern in the Icon Editor Use the Labeling tool to add text to an icon Double click the Labeling tool to change the font or font size of the text Some fonts like Symbol and Glyph contain many small pictures you can use in your
151. mbers the platforms it applies to by number not by name Although these tools do not directly support Windows 3 1 the platform is listed as an option so you can have files specific to Windows 3 1 Refer to the Multiplatform Issues section later in this chapter for more information Local Configuration Each user has to configure the G SCC tools before they can use them by selecting Project Source Code Control Local Configuration The main thing each user needs to do in the SCC Local Configuration dialog box as shown in Figure 11 5 is select the SCC system the administrator configured Ask your SCC administrator to determine which system your site uses Figure 11 5 SCC Local Configuration Dialog Box Configuring the SCC System Users need to choose the SCC system they are using set the local work directory and set the platform option in the SCC Local Configuration dialog box Chapter 11 Source Code Control Tools National Instruments Corporation 11 15 Professional G Developers Tools Reference Manual Built In System Your system administrator should have configured a master directory on a drive or a network to use for storing files under SCC Users need to connect to that network drive so it is accessible to them for reading and writing Select Project Source Code Control Local Configuration to display the SCC Local Configuration dialog box Select Built in from the SCC System drop down menu to display a new dia
152. member of the development team to continue development without having to wait for the other modules to be finished It also makes it easy for the individuals to perform unit testing of their modules as described in Chapter 3 Incorporating Quality into the Development Process As components near completion you can integrate the modules by replacing the stub components with their real counterparts At this point you can perform integration testing to verify the system works as a whole Refer to the Integration Testing section in Chapter 3 Incorporating Quality into the Development Process for more information Front Panel Prototyping As mentioned in Chapter 2 Development Models front panel prototypes can provide insight into the organization of your program Assuming your program is user interface intensive you can attempt to create a mock interface that represents what the user sees Avoid implementing block diagrams in the early stages of creating prototypes so you do not fall into the code and fix trap Instead create just the front panels As you create buttons list boxes and rings think about what should happen as the user makes selections Ask yourself questions such as the following Should the button lead to another front panel Should some controls on the front panel be hidden and replaced by others If new options are presented follow those ideas by creating new front panels to illustrate the results This ki
153. ms with a number of data points or high transfer rate requirements test the performance related components early because the test might prove your design assumptions are incorrect For example if you plan to use an instrument as your data acquisition system you might want to build some simple tests that perform the type of I O you plan to use While the specifications might seem to indicate that the instrument can handle the application you are creating you might find that triggering for example takes longer than you expected that switching between channels with different gains cannot be done at the necessary rate without reducing the accuracy of the sampling or that even though the instrument can handle the rates you do not have enough time on the software side to perform the desired analysis A simple prototype of the time critical sections of your application can help reveal this kind of problem The timing template example in the examples general structs llb directory illustrates how to time a process Because timings can fluctuate from one run to another for a variety of reasons you should put the operation in a loop and display the average execution time You also can use a graph to display timing fluctuations Causes of timing fluctuations can include system interrupts screen updates user interaction and initial buffer allocation Chapter 4 Prototyping and Design Techniques National Instruments Corporation 4 11 Profession
154. must perform local configuration Refer to the Administrator Setup and Local Configuration sections in Chapter 11 Source Code Control Tools for more information Chapter 1 Introduction Professional G Developers Tools Reference Manual 1 2 National Instruments Corporation Overview LabVIEW and BridgeVIEW are flexible tools for using a graphical programming language called G to design test measurement and process monitoring and control applications National Instruments designed G as an easy to use general purpose language Because G is a fully functional programming language LabVIEW and BridgeVIEW deal with complex applications that cannot be developed easily using more restrictive data acquisition and control applications G emphasizes hierarchical design and reuse with its concept of a VI Each VI is a complete program that consists of a front panel that provides a user interface and a block diagram that represents the source code The block diagram describes the relationship and interactions between inputs and outputs in the user interface Every VI is a reusable component You can define a calling interface and a representative icon so you can call the VI as a subroutine or subVI from other VIs Because VIs can be stored in separate files multiple developers can work on different parts of a project simultaneously As with other programming languages developing and managing large applications with multiple developers require
155. n Usually you should avoid bottom up system design It is sometimes useful when used in conjunction with top down design Bottom up design is the exact opposite of top down design You start by building the lower level components and then progressing up the hierarchy gradually putting pieces together until you have the complete system The problem with bottom up design is that because you do not start with a clear idea of the big picture you might build pieces that do not fit together the way you expect There are specific cases in which using bottom up design is appropriate If the design is constrained by low level functionality you might need to build that low level functionality first to get an idea of how it can be used This might be true of an instrument driver where the command set for the instrument constrains you in terms of when you can do certain operations For example with a top down design you might break up your design so configuration of the instrument and reading a measurement from the instrument are done in distinct VIs The instrument command set might Read Data Process Data Save Data Displays Chapter 4 Prototyping and Design Techniques National Instruments Corporation 4 7 Professional G Developers Tools Reference Manual turn out to be more constraining than you thought requiring you to combine these operations In this case with a bottom up strategy you might start by building VIs that deal wit
156. n any language really cannot exist because what one group prefers another group might disagree with Select a set of guidelines that works for you and your development team Chapter 3 Incorporating Quality into the Development Process National Instruments Corporation 3 11 Professional G Developers Tools Reference Manual Design Reviews Design reviews are a great way to identify and fix problems during development When the design of a feature is complete set up a design review with at least one other developer Discuss quality goals asking questions such as the following Does the design incorporate testing Is error handling built in Are there any assumptions in the system that might be invalid Also look at the design with an eye for features that are essential as opposed to features that are extras There is nothing wrong with building in extra features If quality and schedule are important however you should ensure that these extra features are scheduled for late in the development process so they can be dropped or moved to the list of features for subsequent releases Document the results of the design review and any recommended changes Code Walkthroughs A code walkthrough is similar to a design review except that it analyzes the code instead of the design To perform a code review give one or more developers printouts of the VIs to review You might want to perform the review online because VIs
157. n the new knowledge you gained from building the prototype In the final phase you evaluate the results with the customer Based on customer input you can reassess the situation decide on the next highest risk and start the cycle over This process continues until the software is finished or you decide the risks are too great and terminate development You might find that none of the options is viable because each is too expensive time consuming or does not meet the requirements Table 2 1 Risk Exposure Analysis Example ID Risk Probability Loss Risk Exposure Risk Management Approach 1 Acquisition rates too high 5 9 45 Develop prototype to demonstrate feasibility 2 File format might not be efficient 5 3 15 Develop benchmarks to show speed of data manipulation 3 Uncertain user interface 2 5 10 Involve customer develop prototype Chapter 2 Development Models National Instruments Corporation 2 11 Professional G Developers Tools Reference Manual The advantage of the spiral model over the waterfall model is that you can evaluate which risks to take care of with each cycle Because you can evaluate risks with prototypes much earlier than in the waterfall process you can deal with major obstacles and select alternatives in the earlier stages which is less expensive With a standard waterfall model you might have allowed assumptions about the risky components to spread throughout your design
158. nce double click an item in the differences list or select an item and click the Show Difference button To highlight a detail double click an item in the details list or select an item and click the Show Detail button A checkmark indicates the items you selected You also can use the Tile Left and Right and the Tile Up and Down buttons to tile the windows of the two VIs you are comparing Click the Clear button to clear the differences list If you have made edits after a comparison some of the differences might be stale Click the Update button to again compare the two VIs and update the differences list You also can show the Differences window by selecting Project Show Differences Chapter 10 VI Comparison Tools Professional G Developers Tools Reference Manual 10 4 National Instruments Corporation When you highlight a difference objects that are part of the difference are selected The Circle Differences checkbox option allows you to draw a red circle around the object s that has changed Figure 10 3 shows an example of a block diagram difference Figure 10 3 Block Diagram Difference In Figure 10 3 the circled objects are inserted into the block diagram Objects selected but not circled are not differences They are selected as anchor objects to provide reference points for the difference Objects that appear dimmed are not part of the difference Chapter 10 VI Comparison Tools National Instruments Corporation 10 5
159. nd of prototyping can help solidify the requirements for a project and give you a better idea of its scope Chapter 4 Prototyping and Design Techniques Professional G Developers Tools Reference Manual 4 10 National Instruments Corporation Prototyping cannot solve all development problems however You have to be careful how you present the prototype to customers Prototypes can give an overly inflated sense that you are rapidly making progress on the project You have to be clear to the customer whether it is an external customer or other members of your company that this prototype is strictly for design purposes and that much of it will be reworked in the development phase Another danger in prototyping is that you might overdo it Consider setting strict time goals for the amount of time you will prototype a system to prevent yourself from falling into the code and fix trap Of course front panel prototyping deals only with user interface components As described here it does not deal with I O constraints data types or algorithm issues in your design The front panel issues might help you better define some of these areas because it gives you an idea of some of the major data structures you need to maintain but it does not deal with all these issues For those issues you need to use one of the other methods described in this chapter such as performance benchmarking and top down design Performance Benchmarking For I O syste
160. nfiguration 1 1 Index Professional G Developers Tools Reference Manual I 6 National Instruments Corporation project management SCC tools 11 17 to 11 23 adding extra files 11 21 to 11 22 creating projects 11 18 to 11 20 Edit Extra Files dialog box 11 22 Edit Project File List dialog box 11 19 Edit Project Group dialog box 11 23 managing multiple hierarchies 11 17 overview 11 17 project groups 11 22 to 11 23 removing files from projects 11 21 SCC File Wizard 11 20 SCC Project dialog box 11 18 updating projects 11 20 to 11 21 project tracking See scheduling and project tracking prototyping See also design techniques development model 2 7 to 2 8 front panel prototyping 4 9 to 4 10 G prototyping methods 2 8 Q quality control 3 1 to 3 17 code walkthroughs 3 11 to 3 12 configuration management 3 2 to 3 5 change control 3 4 to 3 5 managing project related files 3 3 retrieving old versions of files 3 3 to 3 4 source code control 3 2 to 3 3 tracking changes 3 4 design reviews 3 11 postmortem evaluation 3 12 requirements 3 1 to 3 2 software quality standards 3 13 to 3 17 CMM 3 15 to 3 16 FDA standards 3 14 IEEE 3 16 to 3 17 ISO 9000 3 13 to 3 14 style guidelines 3 10 testing guidelines 3 5 to 3 10 black box and white box testing 3 6 formal methods of verification 3 9 to 3 10 integration testing 3 8 to 3 9 system testing 3 9 unit testing 3 7 R ranges of values for controls
161. ng Consistent Style The G Style Guide Professional G Developers Tools Reference Manual 7 20 National Instruments Corporation Sequence Structures Avoid overusing Sequence Structures G has a great deal of inherent parallelism Using a Sequence Structure guarantees the order of execution but prohibits parallel operations For instance asynchronous tasks that use I O devices such as GPIB serial plug in boards can run concurrently with CPU bound operations Sequence Structures add no code or execution overhead but they do restrict parallelism Actually your program might execute faster if you can add parallelism by reducing the use of sequences Sequences also hide parts of the program and interrupt the natural left to right flow of data While pure dataflow programming means avoiding Sequence Structures there are cases where it is appropriate to use them Use Sequence Structures only if one node must execute before another and cannot be connected by a wire Refer to the Data Dependency section earlier in this chapter for more information Sequence Structures also can be used to conserve screen space although proper use of subVIs is better Lesson 8 Additional Topics in the LabVIEW Basics II Course Manual describes a State Machine which is an alternative to the Sequence Structure Use a Case Structure wired to a counter in a For or While Loop This technique allows you to jump around in the sequence by manipulating the counter Fo
162. ng User Documentation 6 2 Documentation for a Library of SubVIs 6 2 Documentation for an Application 6 3 Creating Help Files 6 4 VI and Control Descriptions 6 5 VI Description 6 5 Self Documenting Front Panels 6 5 Control and Indicator Descriptions 6 6 Chapter 7 Using Consistent Style The G Style Guide VI Hierarchy 7 1 Hierarchy with VI Libraries 7 3 Front Panels with Style 7 4 Consistency 7 4 Text
163. nstead of VI Libraries section you can develop under Windows 95 NT using directories When it is time to test and ship under Windows 3 1 you can save your files into LLBs There are some disadvantages to saving VIs in a VI library First as a VI library grows it takes longer to save VIs to it because a copy of the entire library must be made during the save Second VIs inside a VI library are not visible to your computer file management system so the Find File command of the operating system cannot find them The third disadvantage to LLBs is the lack of hierarchy within a VI library You can simulate one level of hierarchy by marking some VIs as top level VIs by selecting File Edit VI Library Top level VIs are listed above and apart from the others in the File Dialog dialog box when you select File Open as shown in Figure 7 2 Figure 7 2 Top Level VIs Listed at the Top of a VI Library Chapter 7 Using Consistent Style The G Style Guide Professional G Developers Tools Reference Manual 7 4 National Instruments Corporation If you use LLBs use a combination of directories and VI libraries to use the advantages and avoid the disadvantages of both Separating main VIs and subVIs into two or more VI libraries in the same directory makes the VI libraries smaller and the hierarchy more obvious as shown in Figure 7 3 Figure 7 3 Mixture of Directories and VI Libraries You might move the LLBs that contain subVIs into subdir
164. nt Graphics and Custom Controls You can enhance the functionality of your front panel with imported graphics You can import bitmaps Macintosh PICTs Windows Enhanced Metafiles and text objects for use as backgrounds or in pict rings and custom controls as shown in Figure 7 4 Figure 7 4 Example of Imported Graphics Used in a Pict Ring Use a pict ring when a function or mode is conveniently described by a picture A custom Boolean control that is transparent in one state appears when the state changes A completely transparent Boolean is useful for detecting mouse clicks in specified regions of the screen Check how your imported pictures look when your VI is loaded on another platform For example a Macintosh PICT file that has an irregular shape might convert to a rectangular bitmap with a white background under Windows or UNIX Chapter 7 Using Consistent Style The G Style Guide National Instruments Corporation 7 7 Professional G Developers Tools Reference Manual One disadvantage of imported graphics is that they slow down screen updates The following suggestions might improve performance Make sure indicators and controls are not placed on top of a graphic object That way the object does not have to be redrawn each time the indicator is updated If you must use a large background picture with controls on top of it try breaking it into several smaller objects and import them separately Large graphics
165. nt on our products and manuals The Glossary contains an alphabetical list and description of terms used in this manual including abbreviations and acronyms The Index contains an alphabetical list of key terms and topics in this manual including the page where you can find each one Conventions Used in This Manual The following conventions are used in this manual lt gt Angle brackets enclose the name of a key on the keyboard for example lt Shift gt A hyphen between two or more key names enclosed in angle brackets denotes you should simultaneously press the named keys for example lt Control Alt Delete gt The symbol leads you through nested menu items and dialog box options to a final action The sequence File Page Setup Options Substitute Fonts directs you to pull down the File menu select the Page Setup item About This Manual National Instruments Corporation xv Professional G Developers Tools Reference Manual select Options and finally select the Substitute Fonts option from the last dialog box This icon to the left of bold italic text denotes a note which alerts you to important information bold Bold text denotes the names of menus menu items parameters dialog boxes dialog box buttons or options icons palettes or windows bold italic Bold italic text denotes a note lt Control gt Key names are capitalized italic Italic text denotes variables emphasis
166. obtain support Country Telephone Fax Australia 03 9879 5166 03 9879 6277 Austria 0662 45 79 90 0 0662 45 79 90 19 Belgium 02 757 00 20 02 757 03 11 Brazil 011 288 3336 011 288 8528 Canada Ontario 905 785 0085 905 785 0086 Canada Qu bec 514 694 8521 514 694 4399 Denmark 45 76 26 00 45 76 26 02 Finland 09 725 725 11 09 725 725 55 France 01 48 14 24 24 01 48 14 24 14 Germany 089 741 31 30 089 714 60 35 Hong Kong 2645 3186 2686 8505 Israel 03 6120092 03 6120095 Italy 02 413091 02 41309215 Japan 03 5472 2970 03 5472 2977 Korea 02 596 7456 02 596 7455 Mexico 5 520 2635 5 520 3282 Netherlands 0348 433466 0348 430673 Norway 32 84 84 00 32 84 86 00 Singapore 2265886 2265887 Spain 91 640 0085 91 640 0533 Sweden 08 730 49 70 08 730 43 70 Switzerland 056 200 51 51 056 200 51 55 Taiwan 02 377 1200 02 737 4644 United Kingdom 01635 523545 01635 523154 United States 512 795 8248 512 794 5678 Technical Support Form Photocopy this form and update it each time you make changes to your software or hardware and use the completed copy of this form as a reference for your current configuration Completing this form accurately before contacting National Instruments for technical support helps our applications engineers answer your questions more efficiently If you are using any National Instruments hardware or software products related to this problem include the configuration forms from their user
167. ocesses might not be mature enough to deal with significantly different types of projects Chapter 3 Incorporating Quality into the Development Process National Instruments Corporation 3 15 Professional G Developers Tools Reference Manual Figure 3 1 illustrates the five levels of the CMM and the processes necessary for advancement to the next level Figure 3 1 Capability Maturity Model Most companies are at Level 1 or 2 The U S Department of Defense prefers a Level 3 or higher CMM assessment in bids on new government software development Some commercial companies mainly in the United States also use the CMM The CMM differs from ISO 9001 in that it is software specific Also the ISO specifications are fairly high level documents ISO 9001 is only a few pages CMM is very detailed with more than 500 pages Level 3 Defined The organization establishes a baseline set of policies for all projects Groups are well trained and know how to customize this set of policies for specific projects Each project has well defined characteristics that make it possible to accurately measure progress Level 4 Managed The organization sets quality goals for projects and processes and measures progress toward those goals Level 5 Optimizing The organization emphasizes continuous process improvement across all projects The organization evaluates the software engineering techniques it uses in different groups and applies them th
168. odes CINs 7 25 data dependency 7 19 error checking 7 21 to 7 23 execution sequence 7 18 to 7 21 labeling 7 18 left to right layouts 7 18 missing dependencies 7 20 to 7 21 optimization 7 24 Sequence Structures 7 20 sizing and positioning 7 23 to 7 24 wiring etiquette 7 17 top down design 4 2 to 4 3 bottom up design 4 6 to 4 8 BridgeVIEW software 1 2 bulletin board support B 1 C Capability Maturity Model CMM standards 3 15 to 3 16 changes See configuration management Source Code Control tools CINs CIN shared library statistics 8 4 description contents 7 25 source code 7 25 ClearCase for Solaris 2 accessing previous versions of files 11 33 administrator setup 11 10 to 11 12 advantages and disadvantages 11 5 local configuration 11 15 to 11 16 support for 11 5 CMM Capability Maturity Model standards 3 15 to 3 16 COCOMO Constructive Cost Model estimation 5 6 code and fix model 2 4 Code Interface Nodes CINs See CINs code walkthroughs 3 11 to 3 12 See also design reviews coercion of invalid values 7 10 to 7 11 color style guidelines for 7 5 to 7 6 common input output terminal pairs 7 19 common operations identifying 4 11 to 4 12 Compare Files command 10 7 Compare Files dialog box 10 4 Compare Hierarchies command 10 1 to 10 4 Compare VI Hierarchies dialog box 10 2 to 10 3 comparison options 10 3 showing differences 10 3 to 10 4 Compare VI Hierarchies dialog box 10 2 to 10 3
169. of files 7 1 to 7 4 directories folders 7 1 to 7 2 naming VIs VI libraries and directories 7 2 VI libraries 7 3 to 7 4 hierarchies for projects multiple 11 17 hierarchies of VIs comparing See Compare Hierarchies command History window 6 2 11 27 HTML Hypertext Markup Language for documentation 9 2 I icons style considerations 7 15 to 7 16 IEEE Institute of Electrical and Electronic Engineers standards 3 16 to 3 17 indicators See controls and indicators installation 1 1 Institute of Electrical and Electronic Engineers IEEE standards 3 16 to 3 17 integration testing 3 8 to 3 9 International Organization for Standards ISO 9000 3 13 to 3 14 K keyboard navigation 7 11 to 7 12 L labels block diagrams 7 18 font usage 7 5 Index National Instruments Corporation I 5 Professional G Developers Tools Reference Manual style guidelines 7 8 to 7 9 LabVIEW software version required 1 2 left to right layouts 7 18 libraries See VI libraries lifecycle models 2 4 to 2 11 code and fix model 2 4 definition 2 4 G prototyping methods 2 8 modified waterfall model 2 7 prototyping 2 7 to 2 8 spiral model 2 9 to 2 11 waterfall model 2 5 to 2 7 lines of code See Source Lines of Codes SLOCs metric LLBs See VI libraries local configuration SCC tools 11 14 to 11 17 built in system 11 15 ClearCase 11 15 to 11 16 local work directory 11 16 to 11 17 Platform drop down menu 11 17 Vi
170. of top level indicators on a VI front panel A cluster or an array is counted as a single indicator Attribute reads Number of attribute reads by a VI block diagram If you read multiple attributes with the same attribute node each attribute increments this number Attribute writes Number of attribute writes by a VI block diagram If you write multiple attributes with the same attribute node each attribute increments this number Globals Locals Statistics Global reads Number of reads of global variables in a VI block diagram Global writes Number of writes to global variables in a VI block diagram Local reads Number of reads of local variables in a VI block diagram Local writes Number of writes to local variables in a VI block diagram CINs Shared Library Statistics CINs Number of Code Interface Nodes in a VI block diagram Shared library calls Number of Call Library Nodes in a VI block diagram Chapter 8 VI Metrics Tool National Instruments Corporation 8 5 Professional G Developers Tools Reference Manual SubVI Interface Statistics Connector inputs Number of controls on a VI connector pane Connector outputs Number of indicators on a VI connector pane Files in vi lib By default the VI Metrics dialog box excludes VIs in vi lib from the listing and from the totals Calls to vi lib VIs are counted as nodes but information about the num
171. ofessional G Developers Tools Reference Manual 3 8 National Instruments Corporation Integration Testing You perform integration testing on a combination of units Unit testing usually finds most bugs but integration testing might reveal unanticipated problems Modules might not work together as expected They might interact in unexpected ways because of the way they manipulate shared data For more information refer to Chapter 28 Performance Issues in the G Programming Reference Manual Integration testing also can be done in earlier stages before you put the whole system together For example if a developer creates a set of VIs that communicates with an instrument he or she could develop unit tests to verify that each subVI correctly sends the appropriate commands He or she also could develop integration tests that use several of the subVIs in conjunction with each other to verify that there is not any unexpected interaction Integration testing should not be performed as a comprehensive test in which you combine all the components and try to test the top level program Doing this can be expensive because it is difficult to determine the specific source of problems within a large set of VIs Instead you should consider testing incrementally with a top down or bottom up testing approach With a top down approach you gradually integrate major components testing the system with the lower level components of the system disabled or
172. ol before and after a project phase is complete to specifications test plans and code Testing Guidelines You should decide up front what level of testing is expected Engineers under deadline pressure frequently give short attention to testing devoting more time to other development Most software engineers will tell you however that a certain level of testing is guaranteed to save you time The degree to which you expect developers to test should be clearly understood Also testing methodologies should be standardized and results of tests should be tracked As you develop the requirements and design specifications you also should develop a test plan to help you verify the system and all its components work Testing should reflect the quality goals you want to achieve For example if performance is more critical than robustness you should develop more tests for performance and fewer that attempt incorrect input low memory situations and so on Chapter 3 Incorporating Quality into the Development Process Professional G Developers Tools Reference Manual 3 6 National Instruments Corporation Testing should not be an afterthought It should be considered part of the initial design phases and should be implemented throughout development to find and fix problems as soon as possible There are a variety of testing methodologies you can use to help increase the quality of your VI projects The following sections describe some test
173. on from the server A developer can check out the file make modifications test the changes and check in the file to the source code system After the file is checked in it is accessible to the whole development team again Another developer can then check out the file to make further modifications The G Source Code Control tools are accessible from the Project menu Refer to Chapter 11 Source Code Control Tools for more information on these tools Managing All Project Related Files The G Source Code Control tools can manage more than just VIs You can use them to manage all aspects of your project requirements specifications illustrations reviews and other documents related to your project This ensures that you can control access to these documents and share them as needed You can use the tools to track changes and access older versions of files As described in Chapter 4 Prototyping and Design Techniques source management of all project related files is extremely important for developing quality software In fact source management is a requirement for certification under existing quality standards such as ISO 9000 Retrieving Old Versions of Files There are times when you need to retrieve an old version of a file or project This might happen if you make a change to a file and check it in only to realize you made a mistake Another reason it might happen is if you send a beta version of your software to a customer and cont
174. ons proposals and illustrations that describe your project You also can have support files like DLLs or external subroutines The integrated SCC tools support storing these extra project related files as part of your SCC projects Chapter 11 Source Code Control Tools Professional G Developers Tools Reference Manual 11 22 National Instruments Corporation To add extra files to your project select Project Source Code Control Project Select the project in the SCC Project dialog box and click the Edit Project button In the SCC Edit Project File List dialog box click the Extra Files button to display the SCC Edit Extra Files dialog box as shown in Figure 11 8 Figure 11 8 Edit Extra Files Dialog Box Add or remove extra files by selecting them and clicking the Add or Remove buttons Once you are finished click the Save button to commit any changes you make Do not use the SCC Edit Extra Files dialog box to add VIs to a project VIs should be added automatically if they are part of a hierarchy If you have a set of VIs that are not part of the project but that you want to store in Source Code Control create new project s for the additional VIs If you want to be able to retrieve multiple projects simultaneously as though they were a single project create a project group Refer to the following Project Groups section for more information Project Groups Each SCC project consists of a VI all or some of its subVIs
175. opean Norm EN 29000 Series In Canada it has been adopted by the Canadian Standards Association CSA as the Q 9000 series However it is most commonly referred to as ISO 9000 in all countries ISO 9000 is an introduction to the ISO 9000 family of standards ISO 9001 is a model for quality assurance in design development production installation and servicing Its focus on design and development makes it the most appropriate standard for software products Because the ISO 9000 family is designed to apply to any industry it can be somewhat difficult to apply to software development ISO 9000 3 is a set of guidelines designed to explain how to apply ISO 9001 specifically to software development Chapter 3 Incorporating Quality into the Development Process Professional G Developers Tools Reference Manual 3 14 National Instruments Corporation ISO 9001 does not dictate software development procedures Instead it requires documentation of development procedures and adherence to the standards you set Conformance with ISO 9001 does not guarantee quality Instead the idea behind ISO 9001 is that companies that emphasize quality and follow their documented practices will produce higher quality products than companies that do not U S Food and Drug Administration Standards The U S Food and Drug Administration FDA requires all software used in medical applications to meet its Current Good Manufacturing Practices CGMP One of the
176. or List dialog box the Error window warns you of unwired recommended inputs Chapter 7 Using Consistent Style The G Style Guide National Instruments Corporation 7 15 Professional G Developers Tools Reference Manual If you designate an input as required it must be wired in a calling VI for the VI to work This is appropriate for inputs such as refnums where the VI does not make sense unless the input is wired You should not make an input required unless it is necessary for the VI to execute properly Required inputs appear in bold in the Help window If you make an input optional the Help window does not display it in simple help mode which helps to simplify the connector pane in the Help window With simple help mode turned off the input appears dimmed You should use the optional setting for parameters you rarely need to wire You can specify whether outputs should be recommended or optional but you cannot mark outputs as required Icons Create a meaningful icon for every VI Always create a black and white icon for printouts and menus and add color later The examples and vi lib directories are full of well designed icons that illustrate the functionality of the underlying program Collect ideas for icons You might have to use text if you cannot create a picture However if you intend to send your VIs to customers who speak a language other than English a well chosen icon is much more effective If your VI is a mathe
177. or output with minimal effect on your hierarchy Put at least one input and one output on each subVI to define data flow Error in and error out are ideal dataflow connections If a set of VIs is used together and must be sequenced you can add a common thread Refer to the Adding Common Threads section later in this chapter for more information Position connections for inputs on the left and connections for outputs on the right This conventional left to right data flow prevents complicated unclear wiring patterns Figure 7 8 gives examples of good and bad inputs and outputs Figure 7 8 Good and Bad Inputs and Outputs When several VIs use the same inputs and outputs try to place the inputs and outputs in the same location on each VI For example refnums are usually located at the top left and right of an icon and error I Os are located at the bottom left and right Placing these inputs and outputs in these locations makes it easier to wire icons together On the front panel you can edit required inputs for subVIs by clicking on a terminal in the connector pane at the upper right side of the window and choosing This Connection is from the pop up menu If the connector pane is not visible pop up on the VI icon and select Show Connector From the This Connection is submenu select Required Recommended or Optional By default inputs are all considered to be Recommended If you have the Show Warnings preference enabled in the Err
178. or the VI you load dynamically You should create separate projects for each hierarchy and then create a project group to make it more convenient to access the VI hierarchies simultaneously Refer to the Project Groups section later in this chapter for more information on project groups Chapter 11 Source Code Control Tools Professional G Developers Tools Reference Manual 11 18 National Instruments Corporation Creating a Project To create and edit the contents of projects select Project Source Code Control Project to display the SCC Project dialog box as shown in Figure 11 6 Figure 11 6 SCC Project Dialog Box A Source Code Control project consists of a hierarchy of VIs which is a VI and all or some of its subVIs To create a project open the top level VI you want to add to SCC Select Project Source Code Control Project Click the New Project button in the SCC Project dialog box In the SCC Edit Project File List dialog box select the top level VI for which you want to create a project as shown in Figure 11 7 The project contents listbox updates the list of subVIs the VI calls Chapter 11 Source Code Control Tools National Instruments Corporation 11 19 Professional G Developers Tools Reference Manual Figure 11 7 Edit Project File List Dialog Box If you click the Save button the project is created and all VIs in the listbox are added to SCC if they are not already part of SCC As files are added to
179. orkmanship for a period of 90 days from date of shipment as evidenced by receipts or other documentation National Instruments will at its option repair or replace software media that do not execute programming instructions if National Instruments receives notice of such defects during the warranty period National Instruments does not warrant that the operation of the software shall be uninterrupted or error free A Return Material Authorization RMA number must be obtained from the factory and clearly marked on the outside of the package before any equipment will be accepted for warranty work National Instruments will pay the shipping costs of returning to the owner parts which are covered by warranty National Instruments believes that the information in this manual is accurate The document has been carefully reviewed for technical accuracy In the event that technical or typographical errors exist National Instruments reserves the right to make changes to subsequent editions of this document without prior notice to holders of this edition The reader should consult National Instruments if errors are suspected In no event shall National Instruments be liable for any damages arising out of or related to this document or the information contained in it EXCEPT AS SPECIFIED HEREIN NATIONAL INSTRUMENTS MAKES NO WARRANTIES EXPRESS OR IMPLIED AND SPECIFICALLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE CUSTOMER S RIGH
180. other problems U unit testing Testing only a single component of a system in isolation from the rest of the system Unit testing occurs before the module is incorporated into the rest of the system Glossary Professional G Developers Tools Reference Manual G 4 National Instruments Corporation W waterfall model A lifecycle model that consists of several non overlapping stages beginning with the software concept and continuing through testing and maintenance white box testing Unlike black box testing white box testing creates tests that take into account the particular implementation of the module For example white box testing is used to verify all the paths of execution of the module have been exercised wideband delphi estimation Wideband delphi is a technique used by a group to estimate the amount of effort a particular project will take National Instruments Corporation I 1 Professional G Developers Tools Reference Manual Index A accessing files See file management SCC tools administrator setup SCC tools 11 5 to 11 9 built in system 11 8 to 11 9 ClearCase 11 10 to 11 12 Edit Platform List 11 13 to 11 14 Visual SourceSafe 11 9 to 11 10 alpha testing 3 9 attribute nodes 7 11 B beta testing 3 9 bibliography A 1 to A 2 black box testing 3 6 block diagram statistics 8 3 to 8 4 style considerations 7 17 to 7 25 adding common threads 7 19 checklist 7 28 to 7 29 Code Interface N
181. per s computers is networked you can create a shared location that serves as a central source for development When developers need to modify files they can retrieve them from this location When they are finished with the changes and the system is working they can return the files to this location Common files and areas of overlap introduce the potential for accidental loss of work If two developers decide to work on the same VI at the same time only one developer really can easily merge changes into the project The other developer will have to use the VI Comparison tool to determine the differences and merge the changes into a new version You might avoid this with good communication if each developer notifies the others when he or she needs to work on a specific VI Inevitably however a mistake will be made and work will be lost Chapter 3 Incorporating Quality into the Development Process National Instruments Corporation 3 3 Professional G Developers Tools Reference Manual Source Code Control tools deal with the problems of sharing VIs and controlling access to avoid accidental loss of data Source Code Control tools make it easy to set up shared projects and to retrieve the latest files from the server Once you have created a project you can check out a file for development Checking out a file marks it with your name so that no other developer can modify the file Other developers can however retrieve the current versi
182. peration Three Times 4 11 Figure 7 1 Directory Hierarchy 7 2 Figure 7 2 Top Level VIs Listed at the Top of a VI Library 7 3 Figure 7 3 Mixture of Directories and VI Libraries 7 4 Figure 7 4 Example of Imported Graphics Used in a Pict Ring 7 6 Figure 7 5 Free Labels on a Boolean Control 7 9 Figure 7 6 Front Panel of Range Finder VI 7 10 Figure 7 7 Block Diagram of Range Finder VI 7 10 Figure 7 8 Good and Bad Inputs and Outputs 7 14 Figure 7 9 Good Wiring in a Simple Block Diagram 7 17 Figure 7 10 Example of How Data Acquisition VIs Use Error Clusters 7 19 Figure 7 11 Example of How to Use an Error Cluster 7 23 Figure 7 12 Well Placed Front Panel and Block Diagram 7 24 Figure 8 1 VI Metrics Tool Dialog Box 8 2 Figure 8 2 Block Diagram with Eight Nodes
183. platform modify the CIN code recompile reload the CIN and check the VI back in You might attempt to make the same modifications to the variant of the VI for each platform but this would require a lot of work and is prone to error Instead a better method is to check out the VI on each platform replace it with the VI with the correct block diagram recompile and reload the CIN Afterward you can check in the resulting VI as the variant for the current platform The SCC Check Files In SCC Check Files Out and SCC Retrieve Files dialog boxes restrict the list to the current platform To change the platform select Project Source Code Control Local Configuration to display the SCC Local Configuration dialog box Choose the platform for which you wish to retrieve files After you retrieve the files go back and reset the platform to its original value National Instruments Corporation A 1 Professional G Developers Tools Reference Manual A References This appendix provides a list of references for further information about software engineering concepts LabVIEW Function and VI Reference Manual A useful sample of quality documentation for libraries of VIs Dataflow Programming with LabVIEW National Instruments Application Note A set of perspectives on dataflow programming that shows how LabVIEW compares with classical dataflow graphs equations and block diagrams Visual Programming Using Structured Data Flow Jeffrey
184. project can differ greatly from the calendar time needed to complete the project You might accurately estimate that a VI should take only 2 weeks to develop However in implementation you must fit that development into your schedule You might have other projects to complete first or you might need to wait for another developer to complete his or her work before you can start the project You might have meetings and other events during that time also Chapter 5 Scheduling and Project Tracking National Instruments Corporation 5 7 Professional G Developers Tools Reference Manual Estimate project development time separately from scheduling it into your work calendar Consider estimating tasks in ideal person days which correspond to 8 hours of development without interruption After estimating project time try to develop a schedule that accounts for overhead estimates and project dependencies Remember that you have weekly meetings to attend existing projects to support reports to write and other responsibilities Record your progress at meeting time estimates and schedule estimates Track project time and time spent on other tasks each week This information might vary from week to week but you should be able to determine an average that is a useful reference for future scheduling Recording more information helps you plan future projects accurately Tracking Schedules Using Milestones Milestones are a crucial technique for ga
185. r VI and write a test VI that calls your VI with each combination of inputs and checks the results You can use interactive data logging to create your input sets or test vectors and replay them interactively to re test the VI or automatically from a test VI that uses programmatic data retrieval To perform unit testing you might need to stub out some components that have not been implemented yet or that are being developed For example if you are developing a VI that communicates with an instrument and writes information to a file another developer can work on a file I O driver that writes the information in a specific format To test your components early you might choose to stub out the file I O driver by creating a VI with the same interface This VI can write the data in a format that is easy for you to check You can test the driver with the real file I O driver later during the integration phase as described in the following Integration Testing section Regardless of how you test your VIs record exactly how when and what you tested and keep any test VIs you created This test documentation is especially important if you are creating VIs for paying customers and it is also useful for yourself When you revise your VIs you should run the existing tests to make sure you have not broken anything You also should update the tests for any new functionality you have added Chapter 3 Incorporating Quality into the Development Process Pr
186. r different platforms Select Edit Preferences to make sure the VI Search Path contains lt topvi gt and lt foundvi gt The causes all subdirectories to be searched In Figure 7 1 MyApp vi is the top VI This means that the application will search for subVIs in the directory MyApp before searching the entire disk Once a subVI is found in a directory the application will look in that directory for subsequent subVIs Avoid creating files with the same name anywhere within your hierarchy Only one VI of a given name can be in memory at a time If you have a VI with a specific name in memory and you attempt to load another VI that references a subVI of the same name the VI will link to the VI in memory If you make backup copies of your files be sure to save them into a directory outside the normal search hierarchy Chapter 7 Using Consistent Style The G Style Guide National Instruments Corporation 7 3 Professional G Developers Tools Reference Manual Hierarchy with VI Libraries If you need to create an application or ship VIs to a customer using Windows 3 1 save the VIs into VI libraries LLBs Within LLBs the VIs can have long descriptive names even under Windows 3 1 Only the LLB itself and the directories are subject to the 8 3 character limit Note The G Source Code Control tools described in Chapter 11 Source Code Control Tools do not support LLBs As described in that chapter in the Using Individual Files I
187. r input and an error output You can design the VI to check the error input to see if an error has previously occurred If there is an error the VI can be set up to halt execution and to pass the error input to the error output If there is no error the VI can execute the operation and pass the result to the error output Note In some cases such as a Close operation you might want the VI to perform the operation regardless of the error it receives Using the preceding technique you can easily wire several VIs together connecting error inputs and outputs to propagate errors from one VI to the next At the end of a series of VIs you can use the Simple Error Handler VI to display a dialog box if an error occurs The Simple Error Handler VI is located in the Functions Time amp Dialog palette In addition to encapsulating error handling you can use this technique to determine the order of several I O operations One of the main advantages in using the error input and output clusters is that you can use them to control the execution order of dissimilar operations Chapter 7 Using Consistent Style The G Style Guide National Instruments Corporation 7 23 Professional G Developers Tools Reference Manual The error information is generally represented using a cluster that contains a numeric error code a string that contains the name of the function that generated the error and an error Boolean for quick testing Figure 7 11 shows how
188. r instance any frame can jump directly to an error handling frame Watch Out for Missing Dependencies Make sure you have explicitly defined the sequence of events when necessary Do not assume left to right or top to bottom execution when no data dependency exists In the following example there is no dependency between the Read File and Close File functions More than likely this program cannot work as expected Chapter 7 Using Consistent Style The G Style Guide National Instruments Corporation 7 21 Professional G Developers Tools Reference Manual The following version of the block diagram establishes a dependency by wiring an output of the Read File to the Close File The operation cannot end until the Close File receives the output of the Read File Notice that the preceding example still does not check for errors For instance if the file does not exist the program does not display a warning The following version of the block diagram illustrates one method for handling this problem In this example the block diagram uses the error I O inputs and outputs of these functions to propagate any errors to the simple Error Handler VI Check for Errors When you perform any kind of I O consider the possibility that errors might occur Almost all I O functions return error information Make sure your program checks for errors and you deal with them appropriately BridgeVIEW and LabVIEW do not deal with errors automatically
189. re two enumerations of different types If you wire an enumeration to something that expects a standard numeric you will see a coercion dot because the type is being converted Enumerations are useful for making code easier to read Rings are useful for front panels the user interacts with where you want to programmatically change the strings Chapter 7 Using Consistent Style The G Style Guide Professional G Developers Tools Reference Manual 7 10 National Instruments Corporation Default Values Ranges and Coercion Expect the user to supply invalid values to every control You can check for invalid values in your block diagram or set the control Data Range item to coerce values into the desired range minimum maximum and increment If the values are not evenly spaced such as a 1 2 5 sequence use a function similar to the Range Finder VI shown in Figures 7 6 and 7 7 Figure 7 6 Front Panel of Range Finder VI Figure 7 7 Block Diagram of Range Finder VI Chapter 7 Using Consistent Style The G Style Guide National Instruments Corporation 7 11 Professional G Developers Tools Reference Manual Other difficult situations must be dealt with programmatically Many GPIB instruments limit the permissible settings of one control based on the settings of another For example a voltmeter might permit a range setting of 2 000 V for DC but only 1 000 V for AC If the affected controls like Range and Mode reside in the same VI pu
190. rements document and prototyping a system both described in the Lifecycle Models section later in this chapter can be useful tools to Chapter 2 Development Models Professional G Developers Tools Reference Manual 2 2 National Instruments Corporation clarify goals A second problem with this statement is that diving into development might mean writing code without a detailed design Just as builders do not construct a building without architectural plans developers should not begin building an application without a detailed design Refer to the Code and Fix Model section later in this chapter for more information We don t have time to write detailed plans We re under a tight schedule so we need to start developing right away This situation is similar to the previous example but is such a common mistake that it is worth emphasizing Software developers frequently skip important planning because it does not seem as productive as developing code As a result you develop VIs without a clear idea of how they all fit together and you might have to rework sections as you discover mistakes Taking the time to develop a plan can prevent costly rework at the development stage Refer to the Lifecycle Models section later in this chapter and Chapter 4 Prototyping and Design Techniques for better approaches to developing software Let s try for the whole ball of wax on the first release If it doesn t do everythin
191. rols that are not currently relevant or valid Guide the user through steps by highlighting controls Change screen colors to bring attention to error conditions Key Navigation Some users prefer to use the keyboard instead of a mouse In some environments such as a manufacturing plant only a keyboard is available Even if a mouse is used keyboard shortcuts such as using the lt Enter gt key to select the default action of a dialog box add convenience Chapter 7 Using Consistent Style The G Style Guide Professional G Developers Tools Reference Manual 7 12 National Instruments Corporation For these reasons consider including keyboard shortcuts to your programs Consider the tab order of controls If you select Edit Panel Order you can see the order of your front panel controls This order controls the tab order for your front panel In general set the order to read left to right and top to bottom Pay attention to the key navigation options for buttons on the front panel You can set key navigation options from the Key Navigation item of the pop up menu of any control Set the lt Enter gt key to be the keyboard shortcut to the front panel default control However if you have a multiline string control on the front panel you might not want to use the lt Enter gt key as a shortcut If your front panel has a Cancel button assign a shortcut to the lt Esc gt key You also can use function keys as na
192. roughout the organization Level 5 Optimizing Level 4 Managed Level 3 Defined Tune Processes Based on Measurements Measure Success of Processes Defined Process for Organization Stable Process for Projects Level 2 Repeatable Level 1 Initial Chapter 3 Incorporating Quality into the Development Process Professional G Developers Tools Reference Manual 3 16 National Instruments Corporation Institute of Electrical and Electronic Engineers IEEE Standards IEEE defined a number of standards for software engineering IEEE Standard 730 first published in 1980 is a standard for software quality assurance plans This standard serves as a foundation for several other IEEE standards and gives a brief description of the minimum requirements for a quality plan in the following areas Purpose Reference documents Management Documentation Standards practices conventions and metrics Reviews and audits Test Problem reporting and corrective action Tools techniques and methodologies Code control Media control Supplier control Records collection maintenance and retention Training Risk management As with the ISO standards IEEE 730 is fairly short It does not dictate how to meet the requirements but requires documentation for these practices to a specified minimum level of detail In addition to IEEE 730
193. ruments Corporation xiii Professional G Developers Tools Reference Manual About This Manual The Professional G Developers Tools Reference Manual describes the features functions and operation of the Professional G Developers Tools With these tools you can apply software engineering techniques to G code development This package adds important software engineering tools to LabVIEW and BridgeVIEW In addition this manual describes many of the issues that arise when developing large applications and provides a basic survey of software engineering techniques you might find useful when developing your own projects Organization of This Manual The Professional G Developers Tools Reference Manual is divided into two sections Chapters 2 through 7 describe software engineering concepts Chapters 8 through 11 describe the tools Chapter 1 Introduction introduces you to the features of the Professional G Developers Tools Part I Software Engineering Concepts Chapter 2 Development Models provides examples of some common development pitfalls and describes a number of software engineering lifecycle models Chapter 3 Incorporating Quality into the Development Process describes strategies for producing quality software Chapter 4 Prototyping and Design Techniques gives you pointers for project design including programming approaches prototyping and benchmarking Chapter 5 Scheduling and Project Tra
194. ry as their local directory Once the administrator and users configure their ClearCase systems ClearCase is invisibly integrated into the G Source Code Control interface Take the following steps to complete the administrator setup for ClearCase 1 Install ClearCase if it is not already on your system Refer to the ClearCase documentation for instructions 2 If you want to create public VOBs set up a registry password or locate the existing registry password 3 Create the VOB a Set your umask For shared VOBs the suggested umask setting is 2 b Create a mount point directory such as vobs c Create or choose a directory to store the VOB database such as vobstore d Type cleartool mkvob public tag vobs vobname vobstore vobname vbs where vobs is the mount point directory and vobstore is the directory where the VOB database is stored Chapter 11 Source Code Control Tools National Instruments Corporation 11 11 Professional G Developers Tools Reference Manual e Enter registry password from step 2 if creating a public VOB f Enter comments if any g Restore your umask to its original setting 4 Mount the VOB For example type cleartool mount vobs vobname 5 Provide the name of the VOB for example vobs vobname to users 6 For ClearCase you must specify that VIs are binary files and decide if you want to compress files For each file extension that your VIs use you mus
195. ry with those under SCC Retrieve Files Use to copy files from SCC to your working directory Advanced Use to create reports view the history of files under SCC access previous versions of files and delete files Selecting the Source Code Control System The G Source Code Control tools can integrate with third party Source Code Control systems You can have the SCC tools manage the source internally using the built in system or you can have the tools communicate with a third party system that is responsible for storing retrieving checking in and checking out files The SCC user interface in LabVIEW and BridgeVIEW is the same regardless of whether you use the built in system or a third party system Chapter 11 Source Code Control Tools National Instruments Corporation 11 5 Professional G Developers Tools Reference Manual Currently two third party SCC systems are supported Microsoft Visual SourceSafe for Windows 95 NT and Rational Software ClearCase for Solaris 2 as shown in Figure 11 1 National Instruments might add support for other third party tools in the future based on user demand Figure 11 1 G SCC Tools Can Work with Built In and Third Party Systems In some cases the decision to use one of the third party tools might be made based on the fact that your company has standardized on one of these tools If not you must decide which strategy you want to use for managing your files Built In System
196. s about software quality have increased Consequently a number of organizations have developed quality standards that are specific to software or that can be applied to software When developing software for some large organizations especially government organizations you might be required to follow one of these standards The following sections include a brief overview of the most popular standards Appendix A References lists several documents that contain more information on these standards International Organization for Standards ISO 9000 The International Organization for Standards developed the ISO 9000 family of standards for quality management and assurance Many countries have adopted these standards In some cases governmental bodies require compliance with this ISO standard Compliance generally is measured by certification performed by a third party auditor The ISO 9000 family is widely used within Europe and Asia It has not been widely adopted within the United States although many companies and some government agencies are starting to adopt it In each country the ISO family of standards might be referred to by slightly different names For example in the United States it has been adopted as the ANSI American Society for Quality Control ASQC Q90 Series In Europe it has been adopted by the European Committee for Standardization CEN and the European Committee for Electrotechnical Standardization CENELEC as the Eur
197. s such as quick lab tests or monitoring applications this approach might be appropriate However for larger development projects good planning becomes vital Common Development Pitfalls If you have developed large applications before you probably have heard some of the following statements Most of these approaches start out with good intentions and seem quite reasonable However these approaches are often unrealistic and can lead to delays quality problems and poor morale among team members I haven t really thought it through but I d guess that the project you are requesting can be completed in Off the cuff estimates rarely are correct because they usually are based on an incomplete understanding of the problem When developing for someone else you might each have different ideas about requirements To estimate accurately you both must clearly understand the requirements and work through at least a preliminary high level design so you understand the components you need to develop Refer to chapter Chapter 5 Scheduling and Project Tracking for more information on techniques for estimation I think I understand the problem the customer wants to solve so I m ready to dive into development There are two problems with this statement First lack of consensus on project goals results in schedule delays Your idea of what a customer wants might be based on inadequate communication Developing a requi
198. s answer your questions more efficiently National Instruments Products Hardware revision _______________________________________________________________ Interrupt level of hardware _________________________________________________________ DMA channels of hardware ________________________________________________________ Base I O address of hardware _______________________________________________________ Programming choice _____________________________________________________________ National Instruments software ______________________________________________________ Other boards in system ____________________________________________________________ Base I O address of other boards ____________________________________________________ DMA channels of other boards _____________________________________________________ Interrupt level of other boards ______________________________________________________ Other Products Computer make and model ________________________________________________________ Microprocessor __________________________________________________________________ Clock frequency or speed __________________________________________________________ Type of video board installed _______________________________________________________ Operating system version __________________________________________________________ Operating system mode ___________________________________________________________ Programming lan
199. s in libraries 7 3 Source Code Control tools unavailable 11 5 wiring tips 7 17
200. s into more detailed outlines You can do this by going to the block diagram of what was once a stub VI and filling out its block diagram placing lower level stub VIs on the block diagram that represent each of the major actions the VI must perform Be careful not to jump too quickly into implementing the system at this point One of the objectives here is to gradually refine your design so you can determine whether you have left out any necessary components at higher levels For example when refining the acquisition phase you might realize there is more information you need from the configuration phase If you completely implement one block before you analyze a subsequent block you might need to redesign the first block significantly It is better to try to refine the system gradually on several fronts with particular attention to sections that have more risk because of their complexity The following example illustrates how you might apply top down design techniques to a data acquisition system Data Acquisition System Example This example describes how you might design a general data acquisition system This system must let the user provide some configuration of the acquisition such as rates channels and so on acquire data process the data and save the data to disk Chapter 4 Prototyping and Design Techniques Professional G Developers Tools Reference Manual 4 4 National Instruments Corporation Start to design the VI hier
201. s more rigorous methodologies than simple applications require Poor design and development techniques can lead to applications that are not developed on time are not easy to maintain and contain programming errors that prevent the software from working reliably Software engineering is the field of study related to defining the best processes for developing software These tools are designed to help users apply these techniques to G code development Most software engineering techniques apply to graphical programming languages just as well as they apply to textual programming languages Features of the Tools The Professional G Developers Tools are designed to simplify development of high end large scale applications The tools can help you manage and track code in large development projects These tools are ideal for large teams of developers individual users developing large suites of VIs and G programmers who must adhere to stringent quality standards such as those required by ISO 9000 or the U S Food and Drug Administration Chapter 1 Introduction National Instruments Corporation 1 3 Professional G Developers Tools Reference Manual The tools include features that help you do the following Control source code Integrated Source Code Control tools are accessible from the menus of LabVIEW or BridgeVIEW With these tools you can share VIs with multiple developers You can check out files to begin development and chec
202. scusses the new estimates This process might go on for three or four cycles In most cases you will converge to a small range of values Absolute convergence is not required After the meeting the developer in charge of the project can use the average of the results or he or she might ignore certain outlying values If some tasks turn out to be too expensive for the time allowed he or she might consider adding resources or scaling back the project Even if the estimate is incorrect the discussion from the meetings gives a clear idea of the scope of a project The discussion serves as an exploration tool during the specification and design part of the project so you can avoid problems later For a list of documents that include more information on the wideband delphi estimation method refer to Appendix A References Chapter 5 Scheduling and Project Tracking Professional G Developers Tools Reference Manual 5 6 National Instruments Corporation Other Estimation Techniques Several other techniques exist for estimating development cost These are described in detail in some of the documents listed in Appendix A References The following list briefly describes some popular techniques Function Point Estimation Function point estimation differs considerably from the size estimation techniques described so far Rather than divide the project into tasks that are estimated separately function points are based on a formula app
203. several other IEEE standards related to software engineering exist including the following IEEE 610 Defines standard software engineering terminology IEEE 829 Establishes standards for software test documentation IEEE 830 Explains the content of good software requirements specifications IEEE 1074 Describes the activities that should be performed as part of a software lifecycle without requiring a specific lifecycle model IEEE 1298 Details the components of a software quality management system similar to ISO 9001 Chapter 3 Incorporating Quality into the Development Process National Instruments Corporation 3 17 Professional G Developers Tools Reference Manual Your projects might be required to meet some or all these standards Even if you are not required to develop to any of these specifications they can be helpful in developing your own requirements specifications and quality plans National Instruments Corporation 4 1 Professional G Developers Tools Reference Manual 4 Prototyping and Design Techniques This chapter gives you pointers for project design including programming approaches prototyping and benchmarking When you first begin a programming project deciding how to start can be intimidating A lot of G programmers start immediately with a code and fix development process building some of the VIs they think they will need Then they realize they actually need
204. sional G Developers Tools Reference Manual VI and Control Descriptions You can integrate information for the user in each VI you create by using the VI description feature by placing instructions on the front panel and by including descriptions for each control and indicator VI Description The VI description in the VI Information dialog box from the Windows Show VI Info menu is often a user s only source of information about a VI The Help window displays a VI description when the user moves the mouse cursor over the VI icon either the icon on the VI front panel or the icon used as a subVI in a block diagram Important items to include in a VI description are as follows An overview of the VI function Instructions for use Descriptions of inputs and outputs Self Documenting Front Panels One way of providing important instructions is to place a block of text prominently on the front panel A concise list of important steps is valuable You might even include a suggestion such as Select Show VI Info from the Windows menu for instructions or Select Show Help from the Help menu For long instructions you can use a scrolling string instead of a free label Be sure to pop up and select Data Operations Make Current Value Default to save the text when you finish entering the text If a text block requires too much space on your front panel you can include a highly visible Help button on the front p
205. st Prototype Plan Next Phase Commit to Next Cycle Risk Analysis Chapter 2 Development Models Professional G Developers Tools Reference Manual 2 10 National Instruments Corporation You can use a table to keep track of the top risk items of your project Table 2 1 gives an example of how to do this In general you should deal with the risks with the highest risk exposure first In this example the first spiral should deal with the potential of the data acquisition rates being too high After the first spiral you might have demonstrated that the rates are not too high or you might have to change to a different configuration of hardware to meet the acquisition requirements Each iteration might identify new risks In this example using more powerful hardware might make higher cost a new more likely risk For example assume you are designing a data acquisition system with a plug in data acquisition card In this case the risk is whether the system can acquire analyze and display data quickly enough Some of the constraints in this case are system cost and requirements for a specific sampling rate and precision After determining the options and constraints you evaluate the risks In this example you could create a prototype or benchmark to test acquisition rates After you see the results you can evaluate whether to continue with the approach or choose a different option You do this by reassessing the risks based o
206. sual SourceSafe 11 15 local variables globals locals statistics 8 4 using for consistent values 7 12 to 7 13 M manual See documentation for Professional G Developers Tools Reference metrics See size based metrics VI Metrics tool Microsoft Visual SourceSafe for Windows 95 NT See Visual SourceSafe for Windows 95 NT milestones responding to missed milestones 5 8 tracking schedules using milestones 5 7 to 5 8 missing dependencies 7 20 to 7 21 modified waterfall model 2 7 multiplatform considerations 11 36 to 11 39 cross platform source code control 11 36 Edit Platform List 11 13 to 11 14 filename limitations 11 36 to 11 37 Platform drop down menu 11 17 platform dependent SCC files 11 37 to 11 39 platform specific files 11 38 retrieving files for different platforms 11 39 variants of files for different platforms 11 39 work directory 11 16 to 11 17 multiple hierarchies managing 11 17 N naming filename limitations on various platforms 11 36 to 11 39 VIs VI libraries and directories 7 2 nodes See also size based metrics number of 5 3 8 2 to 8 3 O optimizing programs 7 24 P performance benchmarking 4 10 Platform drop down menu 11 17 platforms See multiplatform considerations postmortem evaluation 3 12 Print Documentation command 6 2 9 1 Print documentation dialog box 6 2 Professional G Developers Tools features 1 2 to 1 3 installation 1 1 overview 1 2 required system co
207. t define an association of these extensions with their file type For most G applications this includes VIs vi controls ctl and globals glb If you use any other extensions you must define file types for those as well a Choose a file type for VIs such as file compressed_file or binary_delta_file You also can define your own file type and type manager Refer to the ClearCase documentation National Instruments recommends compressed_file because binary_delta_file storage does not work as well b You specify this association in a magic file in one of the paths in the magic path Refer to the ClearCase documentation to determine where the magic path is c Somewhere in the search path for magic files create a file with a magic suffix d Add the line compressed_file name vi Replace compressed_file with your chosen file type For controls add the line compressed_file name ctl For global variables add the line compressed_file name glb 7 Set up a view Refer to the ClearCase section later in this chapter for instructions on setting up a view 8 Set the view and launch LabVIEW or BridgeVIEW 9 Select Project Source Code Control Administration 10 Select ClearCase as the Source Code Control system 11 The ClearCase Configuration dialog box opens Chapter 11 Source Code Control Tools Professional G Developers Tools Reference Manual 11 12 National Instruments
208. t the amount of time you will spend prototyping before you begin This helps to avoid overdoing the prototyping phase As you incorporate changes you should update the requirements and the current design After you finish prototyping you might consider returning to one of the other development models For example you might consider prototyping as part of the requirements or design phases of the waterfall model G Prototyping Methods There are a number of ways to prototype a system In systems with I O requirements that might be difficult to satisfy you can develop a prototype to test the control and acquisition loops and rates In I O prototypes random data can simulate data acquired in the real system Systems with many user interface requirements are perfect for prototyping Determining the method you will use to display data or prompt the user for settings can be difficult on paper Instead consider designing VI front panels with the controls and indicators you need You might leave the block diagram empty and just talk through the way the controls would work and how various actions would lead to other front panels For more extensive prototypes you could even tie the front panels together However be careful not to get too carried away with this process If you are bidding on a project for a client using front panel prototypes can be an extremely effective way to discuss with the client how you might be able to satisfy his or her r
209. t the interlock logic there Refer to the Attribute Nodes and Local Variables sections later in this chapter for more information If one or more of the controls are not readily available you can request the present settings from the instrument to ensure you do not try to set an invalid combination There are some speed and memory usage drawbacks to limiting ranges The Data Range function adds some execution overhead as does the Find Range VI and similar VIs If you choose Suspend for range error action the VI front panel remains in memory and will open if a range error occurs This consumes additional memory Controls should have reasonable default values A VI should not fail when run with default values Remember to show the default in parentheses in the control label Do not set default values of indicators like graphs arrays and strings without a good reason because that wastes disk space when saving the VI Use default values intelligently In the case of high level file VIs such as the Write Characters to File VI the default is an empty path that forces the VI to display a File Selection dialog box This can save the use of a Boolean switch in many cases Attribute Nodes Use attribute nodes to give the user more feedback on the front panel There are many things you can do to make your VI easier to use including the following suggestions Set the text focus to the main most commonly used control Dim or hide cont
210. tages when it is easier and much less expensive to make changes The code and fix model is appropriate only for small projects that are not intended to serve as the basis for future development Chapter 2 Development Models National Instruments Corporation 2 5 Professional G Developers Tools Reference Manual Waterfall Model The waterfall model is the classic model of software engineering It has deficiencies but it serves as a baseline for many other lifecycle models The pure waterfall lifecycle consists of several non overlapping stages as shown in Figure 2 1 It begins with the software concept and continues through requirements analysis architectural design detailed design coding testing and maintenance Figure 2 1 Waterfall Lifecycle Model System requirements Establishes the components for building the system This includes the hardware requirements number of channels acquisition speed and so on software tools and other necessary components Software requirements Concentrates on the expectations for software functionality You identify which of the system requirements the software affects Requirements analysis might include determining interaction needed with other applications and databases performance requirements user interface requirements and so on Architectural design Determines the software framework of a system to meet the specified requirements The design defines the major
211. tem Evaluation 3 12 Software Quality Standards 3 13 International Organization for Standards ISO 9000 3 13 U S Food and Drug Administration Standards 3 14 Capability Maturity Model CMM 3 14 Institute of Electrical and Electronic Engineers IEEE Standards 3 16 Chapter 4 Prototyping and Design Techniques Clearly Define the Requirements of Your Application 4 1 Top Down Design 4 2 Data Acquisition System Example 4 3 Bottom Up Design 4 6 Instrument Driver Example 4 7 Designing for Multiple Developers 4 8 Front Panel Prototyping 4 9 Performance
212. ter a password whenever you access files or modify projects Refer to the Selecting the Source Code Control System section earlier in this chapter for more information on the built in system and third party systems Advanced Features You can access most advanced features by selecting Project Source Code Control Advanced to display the SCC Advanced dialog box as shown in Figure 11 15 This dialog box contains features for viewing all files under SCC determining the projects those files belong to accessing older versions of files permanently deleting files and creating reports Figure 11 15 SCC Advanced Dialog Box Chapter 11 Source Code Control Tools National Instruments Corporation 11 31 Professional G Developers Tools Reference Manual Deleting Files from SCC When you remove a file from a project it is not removed automatically from Source Code Control The main reason for this is that although a file might not be needed currently it is important historically in terms of being able to understand the evolution of your software If you later decide you need to retrieve an older version of the project the file is still present in SCC If you decide you do not need a file you can delete it by selecting Project Source Code Control Advanced In the SCC Advanced dialog box select the files you want to delete and click the Delete File button Use caution in deleting files In addition to removing the current version
213. than a more measurable development model Chapter 5 Scheduling and Project Tracking Professional G Developers Tools Reference Manual 5 2 National Instruments Corporation Off the cuff estimates are almost never accurate for the following reasons People are usually overly optimistic An estimate of 2 months at first might seem like an infinite amount of time During the last 2 weeks of the project when developers find themselves working many overtime hours it becomes clear that it is not The objectives implementation issues and quality requirements are not understood clearly When challenged with the task of creating a data monitoring system an engineer might estimate 2 weeks If the product is designed by the engineer and for the engineer this estimate might be right However if it is for other users he or she probably is not considering requirements that might be assumed by a less knowledgeable user but never are specified clearly For example VIs need to be reliable and easy to use because the engineer is not going to be there to correct them if a problem occurs A considerable amount of testing and documentation is necessary Also the user needs to save results to disk print reports and view and manipulate the data on screen If he or she has not discussed or considered the project in detail the engineer is setting himself or herself up for failure Day to day tasks are ignored There are meetings and
214. the software Currently there are many different lifecycle models Each has advantages and disadvantages in terms of time to release quality and risk management This section describes some of the most common models used in software engineering Many hybrids of these models exist so use the parts you believe will work for your project Although this section is theoretical in its discussion in practice you should consider all the steps these models encompass You should consider when and how you decide that the requirements and specifications are complete and how you deal with changes to them The lifecycle model serves as a foundation for the entire development process Good choices in this area can improve the quality of the software you develop and decrease the time it takes to develop it Code and Fix Model The code and fix model probably is the most frequently used development methodology in software engineering It starts with little or no initial planning You immediately start developing fixing problems as you find them until the project is complete Code and fix is a tempting choice when you are faced with a tight development schedule because you begin developing code right away and see immediate results Unfortunately if you find major architectural problems late in the process you might have to rewrite large parts of your application Alternative development models can help you catch these problems in the early concept s
215. the ClearCase documentation for more information cleartool mkview tag viewname viewstorage for example cleartool mkview tag george viewstore george vws Each user should have his or her own view Chapter 11 Source Code Control Tools Professional G Developers Tools Reference Manual 11 16 National Instruments Corporation b Restore umask to original value 3 Set your view For example cleartool setview viewname 4 Choose a label to mark current working versions of files Your userid in all uppercase letters is a good choice Your label must be unique among all who will access a particular VOB 5 Edit your view to show versions with this label a Edit your view With your view set execute cleartool edcs b Using the text editor launched by cleartool add the line element LABELNAME replacing LABELNAME with your chosen label to the view configuration spec just after the line element CHECKEDOUT 6 Launch LabVIEW or BridgeVIEW You must set the view every time you launch LabVIEW or BridgeVIEW 7 Select Project Source Code Control Local Configuration 8 Choose ClearCase as your Source Code Control system 9 Enter the VOB directory name given to you by the administrator in step 1 10 Enter the label name from step 4 11 Click OK 12 Enter your local working directory which must be the same as the VOB directory 13 Click OK 14 To freeze your working set of VIs so that ch
216. the Development Process for more information on techniques for producing high quality software Chapter 2 Development Models National Instruments Corporation 2 3 Professional G Developers Tools Reference Manual We re behind in our project Let s throw more developers onto the problem In many cases doing this actually can delay your project Adding developers to a project requires time for training which can take away time originally scheduled for development Add resources earlier in the project rather than later Also there is a limit to the number of people who can work on a project effectively With a few people there is less overlap You can partition the project so each person works on a particular section The more people you add the more difficult it becomes to avoid overlap Chapter 4 Prototyping and Design Techniques describes methods for partitioning software for multiple developers Chapter 3 Incorporating Quality into the Development Process describes configuration management techniques that can help minimize overlap We re behind in our project but we still think we can get all the features in by the specified date When you are behind in a project it is important to recognize that fact and deal with it Assuming you can make up lost time can postpone choices until it becomes costly to deal with them For example if you realize in the first month of a six month project that you are
217. the VI history Instead the modified text is stored in Source Code Control with the file as part of a log of changes This log is useful for report generation and can be helpful if you later need to retrieve an older version and you need to distinguish between two different versions You can create reports and access old versions by selecting Project Source Code Control Advanced SCC User Name When you check in files or modify projects the G SCC tools use your LabVIEW or BridgeVIEW username to access the Source Code Control system You can change this username by selecting Edit User Name Also you can control whether to prompt for a username when you launch LabVIEW or BridgeVIEW by selecting Edit Preferences to display the Preferences dialog box Select the appropriate options in this dialog box Chapter 11 Source Code Control Tools Professional G Developers Tools Reference Manual 11 30 National Instruments Corporation It is important that the username be unique among your team The built in SCC system does not check for a password so it is possible for users to check files in or out as another developer if you do not use unique names The built in system relies on a certain degree of trust If more security is important consider using an alternative SCC system such as Microsoft Visual SourceSafe or Rational Software ClearCase for Solaris 2 for storing files Visual SourceSafe and other third party tools prompt you to en
218. the files within a VI library individually You would have to check out the entire LLB if you wanted to make changes to any file within the VI library The G SCC tools do not support LLBs because VI libraries do not permit fine enough control over individual VIs The primary reason you might want to use VI libraries is that you need to support Windows 3 1 where filenames are limited The G Source Code Control tools are not supported under Windows 3 1 If you need to support Windows 3 1 consider whether you can develop under other operating systems the G SCC tools support such as Windows 95 NT When developing save your VIs as individual files not in LLBs When you need to release your VIs for use on Windows 3 1 you can save them into LLBs at that point The File Manager tool can help you move VIs to and from VI libraries QuickStart Guide to Using the SCC Tools Following is a brief summary of the steps required for configuring and using the SCC tools 1 Administrator sets up system At least one user in your workgroup should be selected to administer the SCC system This user should select the Administration option when installing the Professional Developers Tools The administrator is responsible for initializing the SCC system and setting up systemwide preferences You do this by selecting Project Source Code Control Administration When you set up the SCC system there are a few decisions you need to make Which stora
219. the quality goals of your project If you are developing to meet a quality standard such as ISO 9000 the format and detail level of these documents are different than the format and detail level of an in house project Appendix A References lists resources that contain information on the types of documents to prepare as part of your development process Chapter 6 Creating Documentation Professional G Developers Tools Reference Manual 6 2 National Instruments Corporation LabVIEW and BridgeVIEW include features that can help you produce some of the documentation you must create You can use some of the following features of these tools to simplify the process History window The History window is a place to record changes to a VI as you make them When you check in a file using the Source Code Control SCC tools described in Chapter 11 Source Code Control Tools the SCC tools retain the History window text You can view it later or print it using the report generation features of the SCC tools SCC report generation In addition to accessing the change history for a file you can view the change history for all files under Source Code Control to see which files have changed and when You also can view listings of the projects under SCC and the files that make up those projects You can view this information on screen or save it to a file so you can import it into a word processor to add it to reports Refer to the Advan
220. tions The Documentation Tool dialog box is shown in Figure 9 1 Figure 9 1 Documentation Tool Dialog Box Chapter 9 Documentation Tool Professional G Developers Tools Reference Manual 9 2 National Instruments Corporation Use the Add Hierarchy Add LLB Add Directory and Add File buttons on the right side of the dialog box to add VI hierarchies from memory add all the files in a directory or LLB or add individual files from disk The files are listed in the listbox in the dialog box after they are added The order of the files controls the order that the VIs appear in the resulting documentation You can reorder the VIs by selecting files from the list and dragging them to the desired location If the paths are too long to view you can deselect the Show Full Paths checkbox at the top of the dialog box When you have the files in the order you want select one of the following buttons to create the documentation Create HTML File With HTML you can make your documentation accessible from the World Wide Web Images are written to external files in PNG JPEG or GIF format based on the format you choose in the Documentation Tool dialog box Refer to Chapter 5 Printing and Documenting VIs in the G Programming Reference Manual for more information about these formats Create RTF File RTF is a standard format that is supported by a number of word processors including Microsoft Word Create Help So
221. truments Corporation Code Interface Node A function in G that allows it to call compiled subroutines from other languages such as C configuration management A mechanism for controlling changes to source code documents and other material that make up a product During software development Source Code Control is a form of configuration management Changes occur only through the Source Code Control mechanism It is also common to implement release configuration management to ensure a particular release of software can be rebuilt if necessary This implies archival development of tools source code and so on F Function Point Estimation A formula based estimation method applied to a category breakdown of project requirements I integration testing Integration testing assures that individual components work together correctly Such testing may uncover for example a misunderstanding of the interface between modules L lifecycle model A model for software development including steps to follow from the initial concept through the release maintenance and upgrading of the software LLB LabVIEW VI Library P prototype A simple quick implementation of a particular task used to demonstrate that the design has the potential to work The prototype usually has missing features and might have design flaws In general prototypes should be thrown away and the feature should be reimplemented for the final version Glossar
222. ts of the package examples of how to use the subVIs and a detailed description of each subVI For each subVI you might want to include the VI name and description a picture of the connector pane and the description and a picture of the data type for each of the controls and indicators on the connector pane You can generate much of this documentation easily if you use the description feature for VIs and controls as described in the VI and Control Descriptions section later in this chapter You can use File Print Documentation to create a printout of a VI in a format almost identical to the format used in the VI reference manuals that ship with BridgeVIEW and LabVIEW If you want to incorporate the text into a manual Web page or help file you can use File Print Documentation and then select the destination from the Destination drop down menu If you want to create documentation for multiple VIs all at once use Project Documentation Tool Refer to Chapter 9 Documentation Tool for more information Documentation for an Application If you are developing an application for users who are not familiar with LabVIEW or BridgeVIEW your documentation requires more introductory material Your documentation should cover basic features such as installation and system requirements It should provide an overview of how the package works If the package uses I O describe the necessary hardware and any configuration that must be done before
223. uging progress on a project If completing the project by a specific date is important consider setting milestones for completion Set up a small number of major milestones for your project making sure each one has clear requirements To minimize risk set milestones to complete the most important components first If after reaching a milestone the project falls behind schedule and there is not enough time for another milestone the most important components will have been completed Throughout development strive to keep the quality level high If you defer problems until a milestone is reached you are in effect deferring risks that might delay the schedule Delaying problems can make it seem like you are making more progress than you actually are Also it can create a situation where you attempt to build new development on top of an unstable foundation When working toward a major milestone set smaller goals to gauge progress Derive minor milestones from the task list you created as part of your estimation A number of the books listed in Appendix A References provide more information about major and minor milestones Chapter 5 Scheduling and Project Tracking Professional G Developers Tools Reference Manual 5 8 National Instruments Corporation Responding to Missed Milestones One of the biggest mistakes people make is to miss a milestone and not reexamine the project as a consequence After missing a milestone many
224. unless you have a specific reason to use a different font For example monospace fonts fonts that are not proportionally spaced are useful for string controls and indicators where the number of characters is critical To set the default font choose it from the Text Settings drop down menu in the toolbar without any text or objects selected You can select all the labels you need to change and set the font in all of them at once using the Text Settings drop down menu in the toolbar The actual font used for the three standard fonts varies depending on the platform your preferences and video driver settings when working under Windows Text might appear larger or smaller To compensate for this allow extra space for larger fonts and keep the Size to Text option on the pop up menu Use carriage returns to make multiline text instead of resizing the text frame You can prevent controls and indicators from overlapping because of font changes on multiple platforms by allowing extra space between controls Fonts are the least portable aspect of the front panel so always test them on all your target platforms Table 7 1 shows suggestions for a consistent set of text styles Color Like fonts it is easy to get carried away with color The particular danger of color is that it distracts the operator from important information For instance a yellow green and bright orange background make it difficult to see a red danger light Another problem
225. urce This produces an RTF file that is formatted for online help hlp files All images are saved as external bitmaps and a help project and table of contents are created These files can then be compiled using a help compiler Refer to the Creating Help Files section in Chapter 6 Creating Documentation for information about compilers for different platforms Print Click this button to print documentation to a printer You can use the Save Script button at the top of the dialog box to save the settings and list of files you create to a file If you click the Load Script button you can restore the settings from the file you created using the Save Script button National Instruments Corporation 10 1 Professional G Developers Tools Reference Manual 10 VI Comparison Tools This chapter describes the VI Comparison tools which you can use to manage different versions of VIs as you develop large applications When you make changes to a VI you might want to compare the VI to an older version to verify the changes you have made Also when multiple users are working on the same VIs you might need to view two versions of the same files to merge changes made by different users You can use the following tools to compare VIs Project Compare Hierarchies Compares two different versions of the same hierarchy of VIs Project Compare VIs Compares two VIs Project Source Code Control Compare Files
226. urceSafe select Project Source Code Control Administration to display the SCC Administration dialog box Select Microsoft Visual SourceSafe from the drop down menu and click the OK button to add configuration files used by the G SCC tools to Chapter 11 Source Code Control Tools Professional G Developers Tools Reference Manual 11 10 National Instruments Corporation the Visual SourceSafe database The G SCC tools maintain the following two files scclist lst This is a master file list the G SCC tools use to maintain information about each file including the projects to which the file belongs sccplats txt This file contains a list of the platforms users can select for retrieving files You also can configure the platforms such as Windows 95 68K Macintosh and so on that a user can select Refer to the Edit Platform List Advanced Option section later in this chapter for more information ClearCase The Professional Developers tools provide the interface for using ClearCase in the G development environment on Solaris 2 The administrator must create a ClearCase Versioned Object Base VOB and an associated storage space outside of G before users can use Source Code Control with ClearCase When the administrator sets up the Source Code Control system from inside G he or she must provide the VOB directory as the master directory Because ClearCase uses a virtual file system users also must use this VOB directo
227. vigation buttons to move from screen to screen If you do this be sure to use the shortcuts consistently Do not use F5 on one front panel and F6 on another front panel for the same action For controls that are offscreen use the Key Navigation dialog box to skip over the controls when tabbing Also you might consider using the Key Focus attribute to set the focus programmatically to a specific control when the front panel opens Local Variables If you have controls with interdependent values use local variables to keep the values consistent and valid For example a VI that generates a square wave might have two inputs period and frequency If the user sets period the VI should detect the change in value and change frequency to the corresponding value Use local variables when you need a control indicator combination For example the VI might set some parameter values using write to controls with local variables but the user must be able to override those values by entering his or her own values using type into controls But avoid using local variables if possible Some users use local variables because it seems like a convenient way to avoid passing wires from one point to another on the block diagram Doing so hides the data flow making the block diagram more difficult to understand and maintain Also using local variables increases the possibility of having race conditions in which multiple locations on the block diagram att
228. ware that can help in small cases but that it is impractical for most programs Style Guidelines Inconsistent approaches to development and to user interfaces can be a problem when multiple developers work on a project Each developer has his or her own style of development color preferences display techniques documentation practices and diagram methodologies One developer might make extensive use of global variables and Sequence Structures while another might prefer to make more use of data flow Inconsistent style techniques can create software that at a minimum looks bad Users might become confused and find the user interface VIs difficult to use if the VIs have different behaviors such as some expecting a user to click a button when he or she is finished and others expecting the user to use a keyboard function key Inconsistent style also makes software difficult to maintain For example if one developer does not like to use subVIs and decides to develop all features within a single large VI that VI will be difficult to modify Establish a set of guidelines for your VI development team Establish an initial set of guidelines and add additional rules as the project progresses You can use these style guidelines in future projects Chapter 7 Using Consistent Style The G Style Guide provides some style recommendations Use these guidelines as a basis for developing your own style guide A single standard for programming style i
229. which requires much more expensive rework when the problems are later discovered Summary Lifecycle models are described as distinct choices from which you must select In practice however you can apply more than one model to a single project You might start a project with a spiral model to help refine the requirements and specifications over several iterations using prototyping Once you have reduced the risk of a poorly stated set of requirements you might apply a waterfall lifecycle model to the design coding testing and maintenance stages Other lifecycle models exist Appendix A References lists documents that contain information about other development methodologies National Instruments Corporation 3 1 Professional G Developers Tools Reference Manual 3 Incorporating Quality into the Development Process This chapter describes strategies for producing quality software Many developers who follow the code and fix style of programming described in Chapter 2 Development Models mistakenly believe they do not need to deal with the issue of quality until the testing phase This is simply not true Quality must be designed into a product from the start Developing quality software begins by selecting a development model that helps you avoid problems in the first place Quality should be considered during all stages of development requirements and specification design coding testing release and maintenance Quality
230. y National Instruments Corporation G 3 Professional G Developers Tools Reference Manual R race conditions Race conditions occur when one block diagram reads from and writes to a global variable and there is the potential that a parallel block diagram attempts to manipulate the same global variable resulting in loss of data S Software Engineering Institute SEI A federally funded research and development center chartered to study software engineering technology The SEI is located at Carnegie Mellon University and is sponsored by the Defense Advanced Research Projects Agency Refer to http www sei cmu edu for more information source lines of code The measure of the number of lines of code that make up a project It is used in some organizations to measure the complexity and cost of a project How the lines are counted depends on the organization For example some organizations do not count blank lines and comment lines Some count C lines and some count only the final assembly language lines spiral model A lifecycle model that emphasizes risk management through a series of iterations in which risks are identified evaluated and dealt with system testing System testing begins after integration testing is complete System testing assures that all the individual components function correctly together and constitute a product that meets the intended requirements This stage often uncovers performance resource usage and
231. y When you are your own customer it is much easier to adjust requirements as you move through the specification and even the design stage If you are developing for someone else changing requirements can be extremely difficult Source Code Control tools give you a degree of control when making changes You can trace all changes and you can configure the system to maintain previous versions so you can back out of changes if necessary Some Source Code Control systems give you more options for controlling software change For example with Microsoft Visual SourceSafe or Rational Software ClearCase for Solaris 2 you can control access to files so some users have access to specific files but others do not You also can specify that anyone can retrieve files but only certain users can make modifications With this kind of access control you might limit change privileges for requirement documents to specific team members Or you might control access so a user has privileges to modify a file only when the change request is approved The amount of control you apply can vary throughout the development process In the early stages of the project before formal evaluation of the requirements you do not necessarily need to restrict change access to files nor do you need to follow formal change request processes Once the requirements are approved however you can institute stronger controls You can apply the same concept of varying the level of contr

Download Pdf Manuals

image

Related Search

Related Contents

3. Installation of the QuickPHOTO INDUSTRIAL 3.0  Inscription portage de repas-2015 - La Roche-sur  Part-No - RIEGL Laser Measurement Systems  RNA Control 250 User Guide    DYEnamic ET Terminator Matrix Standard for the ABI 3700  COMISIÓN DE TRANSPORTE Y VIALIDAD  OM, Rider ProFlex 18, 2001-02  Notes:  Philips LED Spot  