1.  of blood                 For a venous sample   Disinfect venipuncture site with an alcohol wipe  Allow  to dry  Draw sample into syringe     For capillary collection only   Touch the capillary tube to the  drop of blood  Keep the tube  level and allow it to fill by  capillary action  Fill the  capillary tube halfway  Do not  place finger over hole in bulb     Note  Blood may also be applied directly from the finger  to the sample target area              ol    Patient Testing    10     To apply a capillary sample   Place finger over hole in end  of capillary bulb and gently  push down on top of bulb until  sample has been completely  expelled onto the sample  target area  Avoid introducing    air bubbles when applying the sample       To apply a venous sample              Discard the first four drops of blood from the needle   then immediately place one drop of blood from syringe  needle directly onto sample target area of test strip   Avoid introducing air bubbles when applying the sample     Monitor displays the clock  icon  Do not touch the test  strip or add more blood     The result appears in about  one minute  Results are  stored in memory              co             co    CU  i           Patient Testing    11  Remove test strip and discard according to proper  infection control guidelines        12  The flashing test strip icon  reappears on the display  If  you are finished testing  turn  monitor off                 If an up or down arrow is in front  of the result 
2.  the test result is j B re  higher than or lower than the     measuring range of the system     Refer to the Unexpected Results  section of the test strip package  insert for more information  or          Ca  on             Liquid Quality Control Testing    What you need   e CoaguChek S monitor  e Test Strips in foil pouch  e Test Strip Code Chip  e CoaguChek S System  Controls Level 1 and 2  e Timer  Place monitor on a flat surface  free of vibrations  and turn on   Monitor displays code number  Make sure it matches the  code number of the test strips you are using  The test strip  icon flashes                    1  Remove test strips and controls from the refrigerator   Test strips must be out of the refrigerator for at least five  minutes before use     Please Note  Test strips may be stored at room  temperature for up to 60 days  Controls may be stored  at room temperature for up to 30 days     2  Remove control seal by pulling tab              3  Tap vial to settle glass capsule  to bottom of vial                 Liquid Quality Control Testing    4        To avoid the danger of  injuries  it is recom   mended to always  wrap a cloth or gauze  tightly around the vial  before squeezing it     Squeeze to break glass                         capsule  DO NOT BEND vial  Bending may cause glass  to cut through the exterior wall of the vial     The capsule must break     Start a timer for two and a  half minutes  While timer  runs  immediately tap vial  HARD on table top ten time
3. CoaguChek  S  System _    This is a CLIA waived System    Quick  Reference  Guide    Coagulation  Testing with  Fresh Whole Blood    Read your User s Manual  for additional information     May not print or  view at 100     All unmarked  prints black     Coag Swoosh  prints gradients  of PMS 300 on  top and PMS  194 on bottom        The letter    S    in  the  Coag logo  prints PMS300    The word     System    in the  Coag logo prints  50  black   Roche Logo  prints PMS 300   Inside front and    back covers are  blank     Table of Contents    Patent TOSUN g er ascenrseerverren vervent eenen en 3  Liquid Quality Control Testing annae 8  Changing Result Units nanne senen 12  Reviewing Memory             seccececeesesseseseeseseesesessesesseeesesenseeetees 12    Patient Testing    1        What you need    e CoaguChek S monitor   e Test Strips in foil pouch   e Test Strip Code Chip  e Cotton balls or tissue D     e Alcohol wipe Eae A    For a capillary sample    e Lancet   e Capillary tube and bulb Cat  No  461   REF 11621173001   optional    e Lancet device  optional              For a venous sample    e Plastic syringe  anticoagulant free    e Syringe needle should be 23 gauge or larger   A 21 gauge or larger needle is recommended    e Tourniquet    Test strips must be out of the refrigerator for at least five  minutes before use  Keep remaining pouches in  refrigerator     Make sure Test Strip Code Chip number matches the  first three numbers after the lot symbol on the test s
4. both the test results as well as  the results stored in memory to the selected unit s   You also  have the option to switch from single unit display to dual unit  display  See the User s Manual for specific instructions on  dual unit display    1  Place the monitor on a level surface and turn it on    2  When the test strip icon flashes on the display  press the  SET button located at the back of the monitor  The  monitor enters the Set mode    Press the SET button until the primary unit line flashes   Press the Mem button to select the primary units    Press the SET button  The secondary unit line flashes   Press the Mem button to select the secondary units   Press the SET button    Turn the monitor off     ONO e OS    Reviewing Memory   Place monitor on a flat surface and turn it on    Wait for the flashing test strip icon to appear    Press the Mem button  The monitor stores the last 60  results in memory  along with the time and date  The most  recent result is displayed first    Use the Mem button to scroll through the monitor   s memory   The control test results are followed by a    c       Turn the monitor off     12    COAGUCHEK is a trademark of Roche     The CoaguChek S system  monitor and test strips  and its use are covered by  one or more of the following U S  Patents  4 849 340  5 110 727  5 164 598   5 300 779  5 522 255  5 710 622  5 789 664  5 792 944  and 5 886 252     The CoaguChek S monitor and its use are covered by one or more of the  following U S  Pat
5. ents  5 053 199  5 526 111  5 792 944  5 841 023  and  5 886 252     The CoaguChek test strips are covered by U S  Patent No  5 488 816  and  5 975 153       2005 Roche Diagnostics  All rights reserved   12137909003 0705    Our medical professionals are  ready to answer your questions   24 hours a day  7 days a week   365 days a year  Call Roche  Diagnostics Technical Service  Center at 1 800 428 4674     Roche Diagnostics  9115 Hague Road  Indianapolis  IN 46256    www coaguchek com    
6. s  to mix contents     Lay control on table for the  rest of the two and a half  minutes     At the end of two and a half    minutes  turn the monitor ON     When the test strip icon  flashes  open test strip pouch  and remove test strip                                         Liquid Quality Control Testing Liquid Quality Control Testing                                                    9  Insert test strip  The test strip 12  Discard the first drop of  icon appears and the clock control solution into cap   icon flashes  Discard cap with drop   13  Apply the second drop of  control solution to test strip   Avoid introducing air bubbles  into the sample  A hanging    drop must be formed on the   m    bottle tip before applying the  sample to the test strip   10  Once the flashing blood drop 14  Monitor beeps as it detects  icon appears  shake contents wer the drop  of vial down to dropper end  iH Li  PE lle minute 4 Do not disturb test strip while  should have elapsed since mm testing   breaking the glass ampule  Wait for result  Control result   followed by a    c     appears in  the display  Compare result to    Control Value sheet  Lc  en 1  LJ  se                      11  With dropper end down  15      Remove test strip and dispose of control vial and test  remove cap     strip according to proper infection control guidelines        16  Turn monitor off if you are    finished testing  bake                      10 11    Changing Result Units   Note  This procedure changes 
7. trip  pouch  If numbers do not match  see User   s Manual        For capillary sample   Prepare lancet device  Firmly  insert end of capillary tube    into capillary bulb to the line   For venous sample   Prepare a plastic syringe that sa zi     is free of anticoagulant              Patient Testing    4  Place monitor on a flat  surface  free of vibrations   and turn on     Monitor displays code number     Make sure it matches the  code number of the test strips  you are using  The test strip  icon flashes     5  Open test strip pouch and  remove the test strip  It must  be used within FOUR minutes  of opening     6  Gently insert test strip   in the  direction of the arrows    with  printed side facing up  Push  test strip in until it stops     Monitor displays the test strip  icon  The clock icon flashes   Do not apply sample until the  flashing blood drop icon  appears                                      7  When the flashing blood drop          Patient Testing       icon appears  the monitor rer  begins a 180 second   H Lt  countdown  beeping every 30 i  seconds  until sample is   ee uea    applied  Sample must be  applied before the countdown  reaches zero     En  A flashing yellow light through  the test strip indicates where  to apply the blood  x  For a capillary sample              Clean the finger with an  alcohol wipe or use soap and  warm water  Dry thoroughly   Perform fingerstick and gently  squeeze finger to develop a  hanging drop of blood  Use  the first drop
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
STRAUMANN® BONE LEVEL IMPLANT SYSTEM Résumé  User`s Manual - Ward Electronics  Philips Connector ends SWV3032S  American Standard 2474 User's Manual  Synology DS2411+ storage server    Franke ATG 651  INPEFA plug-in for Petrel* Software User Manual  master seal 583  iC- m71 - Icom UK    Copyright © All rights reserved. 