Home

LogicStudio Getting Started Manual - Digi-Key

image

Contents

1. Note Keep in mind that installation interface screens differ slightly between Windows operating systems Regardless of appearance choose the option to Install or Continue Anyway when prompted about LogicStudio drivers 919183 RevA 10 Visit digikey com LogicStudio Click the Continue button to proceed Fe LogicStudio This installer contains both signed and unsigned drivers These drivers are necessary for the complete functionality of LogicStudio and must be installed for this installation to complete successfully When presented with the Windows driver confirmation dialogs please click Install to allow these drivers to be installed When presented with the Windows driver confirmation dialogs please click Continue Anyway to allow these drivers to be installed When plugging in the device for the first time after installation Windows will automatically detect the installed drivers publishers you trust How can I Note The previous screen differs slightly between Windows operating systems Again regardless of appearance choose the option to Continue when prompted The progress of the LogicStudio installation is then shown Fp LogicStudio Installing LogicStudio LogicStudio LogicStudio is being installed Please wait 11 919183 RevA Visit digikey com Getting Started Manual The Wizard then lets you know that you can attach your device to th
2. f I e o a WI corrorarion OD 4 Visit digikey com LeCroy LogicStudio Getting Started Manual December 2010 Visit digikey com LeCro LeCroy Corporation 700 Chestnut Ridge Road Chestnut Ridge NY 10977 6499 Tel 845 578 6020 Fax 845 578 5985 Warranty NOTE THE WARRANTY BELOW REPLACES ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS OR ADEQUACY FOR ANY PARTICULAR PURPOSE OR USE LECROY SHALL NOT BE LIABLE FOR ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES WHETHER IN CONTRACT OR OTHERWISE THE CUSTOMER IS RESPONSIBLE FOR THE TRANSPORTATION AND INSURANCE CHARGES FOR THE RETURN OF PRODUCTS TO THE SERVICE FACILITY LECROY WILL RETURN ALL PRODUCTS UNDER WARRANTY WITH TRANSPORT PREPAID The instrument is warranted for normal use and operation within specifications for a period of one year from shipment LeCroy will either repair or at our option replace any product returned to one of our authorized service centers within this period However in order to do this we must first examine the product and find that it is defective due to workmanship or materials and not due to misuse neglect accident or abnormal conditions or operation LeCroy shall not be responsible for any defect damage or failure caused by any of the following a attempted repairs or installations by personnel other than LeCroy representatives or b
3. i Type Digital Bus P Radix Hex 2 OOOO FONT Y Two s Complement Name D8 D15 Color ME Type Digital P Radix Name oz Color Type Digital Line F Radix The Signals list allows you to conveniently configure all the signals at the same time Each row represents a single signal Inside a single row you can modify the signal Type Name Color and Source Channel s along with additional options depending on the signal Type selected Supported signal Types include Digital Line Digital Bus Digital Wave Analog Channel and I2C SPI UART Decodes Buttons at the top of the Signals list window allow you to add delete and reorder the list Note Making any modifications to the Signals List or the Signal Setup in any way even adding new signals immediately affects currently displayed acquisition data on the Waveform Display Area without requiring a refresh from the device s 25 919183 RevA Visit digikey com Getting Started Manual Instrument The Instrument setup button shows a configuration screen where you can configure how the digital instrument samples data including the half full channel mode selection and setting threshold levels Changes made on the Instrument setup screen take effect on the next acquisition Trigger The Trigger setup button opens a pop up used for configuring trigger conditions for the digital device The trigger pop up has four tabs for differe
4. You can leave the default Installation Folder path or specify a new location Also determine whether or not to install the software for yourself or anyone who uses the computer After making the desired settings click Next to proceed Select Installation Folder LogicStudio The installer will install LogicStudio to the following folder To install in this folder click Next To install to a different folder enter it below or click Browse Folder IC Program Files x86 LeCroyLogicStudio Install Logic Studio for yourself or for anyone who uses this computer gt Everyone Just me 9 919183 RevA Visit digikey com Getting Started Manual The Confirm Installation screen is shown Click Next to start your installation The installer is ready to install LogicStudio on your computer Click Next to start the installation Driver Installation The Wizard then notifies you that the LogicStudio installer contains signed and unsigned drivers Windows prompts you to this affect by showing driver confirmation dialogs Windows Security Would you like to install this device software Name LeCroy Universal Serial Bus controllers Publisher C Speed LLC SF lways trust software from C Speed LLC Install Don t Install _ Y You should only install driver software from publishers you trust How can I decide which device software is safe to install
5. Negative value behaves inversely Analog trigger alignment correction 0 0 31 919183 RevA Visit digikey com Getting Started Manual Help Help information is accessed under Help on the menu bar Access the User Manual to conveniently retrieve this same documentation or click About LogicStudio for the software version and LeCroy contact information A Logos CHO Tell LeCroy Under Help on the menu bar the Tell LeCroy option is always available for providing your feedback It creates and sends an email to LogicStudio support at LeCroy You can even automatically attach your current setup and data with your feedback 919183 RevA 32 LogicStudio Reference China RoHS Compliance E E MTS sA F wih e a co cr em ese A PSA NN RR LSPA ee PlBas KO KK Xx Xx _xX ES VO SJ ID JU Bolt SIT 11363 2006 HF AE f RAT SIT 11363 2006 RIKE EFUP OTRA EA O RE SHSM ME SEH BSE Bil EFUP 5 33 919183 RevA Visit digikey com Visit digikey com Getting Started Manual China RoHS Compliance English Version Toxx or Hazardous Substances and Elements Part Name Hexavalent Polybrominat Polybrominated Chromium ed Biphenyis Diphenyl Ethers Cr PBB PBDE sofa fo s ax ox Jr echancalvar sare o o x o o o gt lead Mercury Cadmium Pb Hg Cd PLEASE NOTE THE FOLLOWING e O Indicates that this toxic or hazard
6. bod e Double clicking a cursor pair button automatically zooms and centers the pair on the Waveform Display Area Mark cursor pairs on signals in the waveform display using the following steps 1 Select a cursor pair 1 4 from the tools detailed control 2 Left click the display to place cursor A of the pair at the first location 3 Now right click the display to place cursor B of the pair at the second location 15 919183 RevA Visit digikey com Visit digikey com Getting Started Manual PLEASE NOTE THE FOLLOWING e The time difference and frequency between A and B is shown on both the Waveform Display Area and on the Cursor s Tool e When a single cursor of the pair is placed the time and frequency is shown in real time based on mouse position until the second half of the pair is placed by right clicking on the waveform e Placing the mouse over the active cursor pair shows the horizontal click and drag mouse icon When this icon appears you can horizontally click and drag a cursor to a new location The display values are updated accordingly e Clicking a created cursor in the waveform display automatically selects the cursor pair and enables the cursor tool e When placing or moving a cursor over any digital signal the software looks for any nearby edges on the signal and snaps the cursor to that edge This allows for easier precise measurements between edges When the cursor is successfully snapped to an
7. edge the cursor s color changes to match the signal Snapping does not occur when the mouse pointer is positioned above or below the waveform e Cursors that cross Analog or Digital Wave signals also display the value of the signal where it meets the cursor as follows 919183 RevA 16 Visit digikey com LogicStudio The following screenshot shows a cursor pair placed on the waveforms display RearView The RearView tool allows you to store and navigate through a history of data acquisitions retrieved from the device s The expanded RearView tool s detailed control looks like the following RearView keeps a history of the last N acquisitions View your stored acquisitions by setting your trigger to Stop and using the slider on the detailed control to flip through the history The currently selected acquisition is shown in the waveform display area You can change the number of stored acquisitions by providing a new number in the text box at the right end of the tool s detailed control The blue bar on the slider control displays how much of the RearView history is being used and available for review This bar fills up as you make new acquisitions until reaching your specified depth at which point the oldest acquisition is discarded when a new one is received Note The RearView tool is always enabled The default acquisition depth is set to 20 records The specific acquisition being viewed is always shown above th
8. the connection and oscilloscope settings and try again e fa connected oscilloscope is not working properly verify the software version of the connected oscilloscope LogicStudio works best with the most recent software version Connected Device Manufacturer VID PID Protocol Interface Seal NVE LECROY Ox05FF 0x0021 Serial LCRY0102726288 Refresh list j ka Disconnect Connect Please connect your instruments as shown below for MSO operation LogicStudio PC Trig Out BNC Coaxial Cable LogicStudio remembers the currently selected oscilloscope which can then be toggled on and off using the Oscilloscope Device Connection button or on the Devices menu Mur Logicstudio 16 eS 1 15 li scope Finder ea Y Simulate Devices Demo Mode 29 919183 RevA Visit digikey com Getting Started Manual If the currently selected oscilloscope cannot be found using either of these means the Scope Finder window is shown During subsequent program startups LogicStudio remembers and if available auto connects to the last selected oscilloscope Note Before you can perform mixed signal acquisitions analog and digital using LogicStudio ensure a proper oscilloscope PC USB connection and make sure the Trig Out line from LogicStudio16 is connected to the external trigger input on your oscilloscope using with the BNC cable provided with your LogicStudio16 A proper connection configuration diag
9. Chief Technology Officer Place LeCroy Corporation 700 Chestnut Ridge Road Chestnut Ridge NY 10977 6499 USA Date 12 8 2010 European Contact Your local LeCroy Sales Office or LeCroy Europe GmbH Waldhofer Str 104 D 69123 Heidelberg Germany Tel 49 6221 82700 Fax 49 6221 834655 35 919183 RevA
10. He O A E A A EE A T E A O 32 919183 RevA lil Visit digikey com LogicStudio elev 32 Ree 33 China ROHS ONE 33 China RoHS Compliance English Version sccscsccsssscsssccsccccscescccsccccsccccsccccscescscsscecsseccececcscesceceseccssecees 34 EC Declaration of Conformity NG 35 iv 919183 RevA Visit digikey com Getting Started Manual This document provides an overview of the LogicStudio application features and describes how to perform various operations Software interface updates may result in a slight difference between screenshots seen in this manual running on Windows Vista and the interfaces you ll find from the software and operating system versions you re running Different versions of the application and or running the application under different operating systems may result in slight interface appearance differences Regardless the differences do not prevent you from easily following the explanations an Logicstudio Demo Mode le e File Devices Setup Help Setup Signals Instr str Trigger 25MHz Sen Haar FT al Ready Auto a ka pl 0 250us ail M fl ONE ji mM KN A Logic Sti AoO System Requirements e Operating System Windows XP Windows Vista 32 or 64 Bit Versions e 1GB RAM minimum 2 GB recommended Package Contents e LogicStudio 16 USB Logic Analyzer e Digital Leadset 16 channels 4 ground e 20 Grippers e 1 USB Ca
11. ble e 1BNCcable e Software Download Instructions 919183 RevA 6 Visit digikey com LogicStudio Safety Requirements This symbol may appear on the product DN This refers you to additional information contained in the operators manual The corresponding information in this manual is similarly denoted Operating Environment Before using your LeCroy LogicStudio 16 ensure its operating environment will be maintained within these parameters e Indoor use e Altitude up to 3000 m e Temperature 5 C to 50 C e Maximum relative humidity 90 for temperatures up to 31 C decreasing linearly to 50 relative humidity at 50 C General Safety Summary Review the following safety precautions to avoid injury and prevent damage to your LeCroy accessory or any products connected to it e Use only as intended Use of this product and or the equipment it is connected to in a manner other than specified may impair the protection mechanisms e Connect and disconnect properly Avoid damage to cables thru excessive bending e Do not use in wet damp or explosive atmospheres e Do not operate with suspected failures Do not use this accessory if any part is damaged All maintenance should be referred to qualified service personnel e Keep product surfaces clean and dry Cleaning The outside of the LogicStudio 16 hardware should be cleaned with a soft cloth dampened with either deionized distilled water or isopropyl alcohol All
12. board above the Persistence and Clear controls This display provides messages when certain device actions are taking a longer period of time For example the Status Display indicates when the software is waiting for a trigger to occur accumulating a large pre post store or downloading data from an oscilloscope Waiting for Ingger Persist Clear Signals Control Panel The signals control panel is located on the main window to the left of the waveform display area as follows Controls on this panel allow for quick and easy signal display modifications gt us 23 18 7 SUS i 919183 RevA 20 Visit digikey com LogicStudio Arranging Your Signals The display of signals can be modified directly through this control as follows e You can rearrange the order of the signals shown in the waveform display area Rolling the mouse over the grip area on the left of a given signal shows the vertical click and drag mouse icon When this icon appears you can vertically click and drag the signal to a new location BD togicStucio Demo O de Ale Devices Setup Help PES setup Saree TE TA ae ta sattsit_tr__at ha laca a O R5 BES 62 5us e You can resize the height of a given signal in the waveform display area by clicking and dragging the bottom edge of a signal to increase decrease its height e Adda new signal to the list by pressing the Add New Signal button With a signals sel
13. bout proper disposal and recycling of your LeCroy product please visit www lecroy com recycle 919183 RevA LogicStudio TABLE OF CONTENTS Non 6 ENRON NNN roinne EEEE AAEE ENEE EEEE 6 Package CONO sta 6 Safety NNN 7 A o o E I sue vueeses eur vusyseuseseseossesoeesore aeuss cupeteusexseees 7 Use and Maintenance nus ai 7 Software and Driver Installation ccccccscsssccscscsccccccscsccccecscsceccccecscsceccecscecescececsceceececscssescecscucecescecscesescess 8 Son ware Ma ON on E EA E A 8 Driver ino aaO e A E E N 10 eva 14 NNN 14 Se 15 Mean Uni 15 TN 15 Tne CUr OS TOON dardo ies 15 ROM Wa do 17 NM 18 MINN 18 RINNAN 19 PN 20 DN 20 PS OP NN 20 Arranging Your Signals EE cesses tes usctecnswuesdeavevensessesagudeveosnasesauesceats 21 The Context Men NT 21 Vue ira PL 22 THe Da TIDE he 23 The Das OO AN Or ao E E aa daaas 24 Dee ETNA 24 PN 24 mm e Pe A E 24 2 a A A o o 25 PP e EEE 26 TUN es cca e a E Eo E ENER eis 26 The IVI OTB i io 28 Save Load Setup Acquisition or Screenshot ccsccsscssccsscsscseccccccscccccescscceccesceeccescsssecsescsssescesessssecss 28 Save LOS Se Diada 28 BA e ni o 28 SS Mo e e o e O EE 28 SN 28 SEE e E E EEE EE 28 De 28 DEE NNN 28 NTN 28 Oscilloscope Models Supported by LogicStudio rrrrrrrrnnanrrnnnnnnrvnnnnnnrrnnnnernnrnnnernrnnnerennnneennrnnssnnnnussennnnnssennnneee 30 Simulate Device EEE EN enerueees 31 o NE NE NE ME ME NE 31 Ihe Mixed Signal PD 31
14. cation or distribution of this program or any portion of it may result in severe Civil or criminal penalties and will be prosecuted to the maximum extent possible under the law Cancel Note Included in this installation process is Microsoft NET 3 5 SP1 Service Pack 1 This version or greater is required to run the LogicStudio software properly 919183 RevA 8 Visit digikey com LogicStudio Agree to the terms of the End User License Agreement by selecting Agree and then click the Next button to continue LogicStudio Please take a moment to read the license agreement now IF you accept the terms below click gree then Nest Othenwse click Cancel END USER LICENSE AGREEMENT FOR LECROY LogicStudio SOFTWARE IMPORTANT READ CAREFULLY THIS END USER LICENSE AGREEMENT EULA Is A LEGAL AGREEMENT BETWEEN THE INDIVIDUAL OR ENTITY LICENSING THE SOFTWARE PRODUCT YOU OR YOUR AND LECROY CORPORATION LECROY FOR THE SOFTWARE PRODUCT S ACCOMPANYING THIS EULA WHICH INCLUDE S COMPUTER PROGRAMS ANY ONLINE OR ELECTRONIC DOCUMENTATION AND PRINTED MATERIALS PROVIDED BY LECROY HEREWITH DOCUMENTATION ASSOCIATED MEDIA AND ANY UPDATES AS DEFINED BELOW COLLECTIVELY THE SOFTWARE PRODUCTA BY USING AN INSTRUMENT TOGETHER WITH OR CONTAINING THE SOFTWARE PRODUCT OR RV TNG amp TATT TY NDIA OF FiITHERTVIGE TETONAS THE METIA RE DE iim T 5 Do Not Agree Gi Agree
15. cator e Auto adjust the view to exactly fit the complete timeframe of any digital and analog data currently displayed by clicking the button directly to the left of the WorldView display Run Modes Four run mode buttons are available on the upper right of the dashboard as follows r Ready Auto Normal Single Stop The modes Auto Normal Single and Stop behave similarly to an oscilloscope e Stop prevents any new acquisitions e Single mode attempts to get exactly one new acquisition while Normal gets repeated acquisitions e Auto mode is similar to normal except it times out and forces a trigger if the current trigger condition hasn t been met within a specified period of time The Run Mode section of the dashboard also contains two green indicators for Ready and Triggered These indicators reflect the state of the digital device at any point in time 19 919183 RevA Visit digikey com Getting Started Manual Persistence Directly above the run mode buttons on the dashboard are the Persistence controls Click the Persist button to toggle the function on off When persistence is on subsequent acquisitions are received and shown on the waveform display Use the Clear button to remove the waveforms from the display and restart your acquisitions Note The Clear button also clears your RearView history Status Display At times an animated status display appears in the upper right corner of the dash
16. configuration It creates a blank email using your default email client and automatically attaches your current setup acquisition data and a screenshot so that you can share them with other LogicStudio users Devices Devices functions are accessed under Devices on the menu bar Device Connections The LogicStudio 16 and oscilloscope options behave exactly like the Device Connections buttons on the dashboard Scope Finder Located under Devices gt Scope Finder the Scope Finder window lists oscilloscopes from supported manufacturers currently attached to your PC via USB The interface allows for selecting a specific oscilloscope enabling LogicStudio connectivity for mixed signal operations analog and digital The list of attached devices automatically updates when the Scope Finder window is opened or whenever items are attached or removed from your PC 919183 RevA 28 LogicStudio Connect to an oscilloscope shown on the list by double clicking its name or highlighting the name and using the Connect and Disconnect buttons Disconnect Connect PLEASE NOTE THE FOLLOWING e It s not necessary to disconnect from an oscilloscope in order to connect to a different one Simply connect to the new one and the previous one is disconnected automatically e fa connected oscilloscope is not on the list it may be an unsupported manufacturer model Otherwise use the Refresh List option force detection If it still does not appear check
17. e computer once the installation has finished Please attach pour device to this computer any time after the installation has finished Note Depending on your operating system Windows shows additional driver interfaces when LogicStudio is actually plugged into your computer Always choose the Install the software automatically option and click the Next button to complete the driver installation Found New Hardware Wizard Welcome to the Found New Hardware Wizard As recommended Install the software automatically installation CD ant the wizard to do 8 Install the software automatically Recommended Install from a list or specific location Advanced Click Next to continue 919183 RevA 12 Visit digikey com LogicStudio The Installation Complete screen is shown Click the Close button to complete the installation cL IS E TE ce Pp Installation Complete LogicStudio LogicStudio has been successfully installed Click Close to exit Please make sure you have the latest drivers for your video card before using LogicStudio Close Now with correct application software and drivers installed your LogicStudio is ready for use 13 919183 RevA DigiKey Visit digikey com Getting Started Manual The Waveform Display Area The Waveform Display Area takes up the largest portion of the application display space because it s where configured signal waveforms are sh
18. e slider control for example in the previous screenshot the tool is showing acquisition 11 of 20 possible acquisitions When you acquire a new acquisition the RearView tool automatically adjusts to show the most recent acquisition TIPS e While using the RearView tool you can modify your signal setup at any time and display additional signals data in different ways than how it may have been set at the time of the actual signal acquisition e You can create a persistence display to compare acquisitions AFTER all the necessary acquisitions have been obtained Do this by enabling persistence mode and then navigating through various acquisitions available in the RearView tool You can even generate a persistence display for a timeframe or zoom level even if the signal data was not yet visible at the time of acquisition 17 919183 RevA Visit digikey com Getting Started Manual Magnifier The Magnifier tool allows you to quickly zoom in on a selected time period of your acquisition without having to adjust your main display or lose your frame of reference Enable the magnifier tool at any time by clicking the main portion of the control Now move your mouse anywhere over the waveform display and an additional time magnified display is drawn inside a boxed magnified area Use the slider control or mousewheel to adjust the magnification factor inside the time magnified display The slider bar updates along with your mousew
19. e solid vertical green bar A The current pre post store setting for the digital device is denoted by the dashed green rectangle B These two indicators align when a new acquisition is obtained however the pre post store control can be adjusted by the user to change the setting for subsequent acquisitions The pre store amount as a percentage of the total digital acquisition is always displayed next to this rectangle The yellow translucent viewbox represents your current view in the waveforms display This shaded region also provides information for relative zoom level and position within the acquired data WorldView control uses include the following e Left click and drag the yellow translucent viewbox to pan the waveform display to the left or right through the acquired data e Increase decrease the current timeframe by left clicking and dragging the left or right edges of the viewbox This adjusts or stretches the left or right most visible time point on the display while leaving the other side pinned e Replace the existing viewbox with a new one by left clicking outside the existing one and dragging to the desired timeframe size e Center your existing viewbox by right clicking outside the existing one This centers the viewbox around the point in time e Change the pre post store setting for the digital device by left clicking and dragging the pre post store control B The ratio displayed as a percentage next to the indi
20. ected in the waveform display area click the Delete Selected Signal button to remove the signal and its configuration Delete signals one at a time The Context Menu Right click on the signal control side of a desired signal to show its corresponding context menu complete with the following options e Add Inserts a new signal after the one currently selected e Remove Deletes the currently selected signal e Show Hide Allows you to remove signals from view without deleting the configuration 21 919183 RevA Visit digikey com Getting Started Manual e Stacked Freeform Modes The signal control panel automatically displays signals in Stacked mode meaning they are shown as individual rows listed in the waveform display area However when you change the signal control panel setting to Freeform mode you can use the grip area s on the left of a given signal vertical click and drag mouse icon to drag signals and superimpose them over other signals in the waveform display area Note When in Stacked mode the grip area s vertical click and drag mouse icon rearranges the order of your signals see Arranging Your Signals for more information instead of superimposing the signals 2 aL i A 0 00 0 00 4 t A FT ee Channels 1 and 2 in Stacked Mode Channel 2 superimposed over Channel 1 using Freeform Mode Modifying a Signal Click a signal s colored name box and corresponding details for the s
21. heel adjustments With the magnifier tool enabled you can still adjust the timeframe of the main waveform display by holding the Control key down while scrolling the mousewheel or dragging with the left and right mouse buttons as normal Tip This tool conveniently provides a quick magnified view of closely aligned edges or visibility of decode and bus value text WorldView The WorldView is an extremely powerful control just above the waveform display on the dashboard Not only does it provide important high level waveform information but it also allows for display configuration and even pre post store settings The control looks like the following 187 36us The WorldView is primarily a high level presentation of the current relationship between your displayed acquisition s and your current view in the main waveforms display 919183 RevA 18 Visit digikey com LogicStudio The display automatically updates to reflect the current conditions whenever display adjustments or a new acquisition is obtained e The blue horizontal bar represents the digital samples acquired The labels on each end of the bar show the time extent of that data relative to the trigger point e The red horizontal bar represents analog samples if present acquired from an attached oscilloscope and the labels on each end of the bar show the time extent of that data relative to the trigger point The trigger point itself is denoted by th
22. ignal are shown on a dialog at the bottom of the waveform display area This dialog shows contents based on the selected signal s type It s also the same dialog used for individual rows on the Signals List setup screen The following screenshot shows a SPI decode signal dialog Type SPI Decode Radix Hex P Data NTN MTT SOUL Bit Order Gal ESB os ax DON OOOO Gama Name SPI Bus color E s OoOO a Son BT Complex Signals Digital Bus Digital Wave and IS2 SPI UART Decode type signals are all complex signals that can be comprised of more than one source channel Signals of these types have an expand collapse button on their right side allowing you to show hide the individual source channels as Digital Line type signals 919183 RevA 22 Visit digikey com LogicStudio These sub signals cannot be directly modified and are automatically named based on how they apply to the complex signal An example of an expanded SPI Decode is shown in the following screenshot The Data Table Clicking the Data Table button on the right edge of a given signal left of the waveform display area shows a pop up The pop up contains a tabular list of all transition data associated with the signal as follows ay SPI Bus Sox 17 64us 34 72us 50 88us 68us 85 08us 101 24us 118 32us 135 44us 152 52us 168 68us 185 76us 202 84us 219us 236 12us 253 2us 269 36us 286 44us 303 56us 320 64us 336 8us 353 88us Fr
23. improper connection to incompatible equipment or c for any damage or malfunction caused by the use of non LeCroy supplies Furthermore LeCroy shall not be obligated to service a product that has been modified or integrated where the modification or integration increases the task duration or difficulty of servicing the instrument Spare and replacement parts and repairs all have a 90 day warranty The instrument firmware has been thoroughly tested and is presumed to be functional Nevertheless it is supplied without warranty of any kind covering detailed performance Products not made by LeCroy are covered solely by the warranty of the original equipment manufacturer Internet www lecroy com 2010 by LeCroy Corporation All rights reserved LeCroy ActiveDSO JitterTrack WavePro WaveMaster WaveSurfer WaveLink WaveExpert Waverunner and WaveAce are registered trademarks of LeCroy Corporation Other product or brand names are trademarks or requested trademarks of their respective holders Information in this publication supersedes all earlier versions Specifications are subject to change without notice This electronic product is subject to disposal and recycling Manufactured under an ISO 9000 regulations that vary by country and region Many countries Registered Quality Management System prohibit the disposal of waste electronic equipment in standard Visit www lecroy com to view the waste receptacles certificate For more information a
24. nt trigger categories Note It s important to note that the trigger logic always runs at a rate of 500 MHz under all modes regardless of the selected Sample Rate This allows you to continue triggering on fast events even when lowering the Sample Rate to obtain a longer timeframe of data However this may result in trigger events that cannot be seen in the slower sampled acquisition data when presented on the waveform display area SIMPLE LOGIC TAB Use this tab to setup simple logic based triggers Modes include Edge Level Pattern and Immediate triggers ADVANCED LOGIC TAB Use this tab to set up more complex logic based triggers You can set the trigger mode from Edge s Width Level s Qualified Level s Pattern and Qualified Pattern choices A different trigger mode can also be selected for each of two trigger blocks A and B and then they can be combined in different logical ways including A only B only A and B A or B A then B and B then A 919183 RevA 26 LogicStudio The yellow arrows update to display the logical flow based on your choice An example of the Advanced tab is shown here mires spe Loge Adwancal log Sera Protocol Emma Orza pr a Tad TT ba a aM MY Add New Pdqr y pan gt y PP ld a FA gt i RAY Wow ee ART Cred Mp SERIAL PROTOCOL TAB Use this tab to define triggers on serial decode signals you may have defined for 12C SPI or UART protocol
25. om this pop up you can scroll through the data use the Radix drop down field to change the data values provided the chosen signal supports your selection The data can also be Exported to a CSV file Clicking or using the up down arrow keys to select a row on the table centers the waveform display timeframe on the selected sample and highlights the transition with a vertical bar glowing in the color of the given signal Use this feature to quickly jump the display to samples of interest on the Data Table Note You can leave this pop up open for one or more signals while you capture new acquisitions The table data updates to show current information as acquisitions are completed 23 919183 RevA Visit digikey com Getting Started Manual The Dashboard The Dashboard is comprised of all control and information GUI elements seen when you first start the application You can perform many powerful operations and quickly access most of the functions from the Dashboard Device Connections Two Device Connection buttons are shown on the upper left corner of the screen just below the menu bars These buttons handle digital pod and oscilloscope device connections respectively Clicking either button attempts to connect to the device or disconnect from the device depending on the current state These buttons have a blue glow when the status is connected ES FUE A red X over the button indicates the device is not curren
26. ous substance contained in all of the homogeneous materials for this part is below the limit requirement specified in SJ T11363 2006 e X Indicates that this toxic or hazardous substance contained in at least one of the homogenous materials used for this part is above the limit requirement specified in SJ T11363 2006 e EFUP Environmental Friendly Use Period Use Conditions Refer to the environmental conditions stated in the specifications section of the Getting Started Manual 919183 RevA 34 Visit digikey com LogicStudio EC Declaration of Conformity according to EN ISO IEC 17050 1 2004 amp 17050 2 2004 Manufacturer s Name LeCroy Corporation Manufacturer s Address 700 Chestnut Ridge Road Chestnut Ridge NY 10977 6499 USA Herewith declare that Product Model LogicStudio 16 including all their options are in conformity with the provisions of the following EC directive s including the latest amendments and with national legislation implementing these directives 2006 95 EC Low Voltage Directive 2004 108 EC EMC Directive and that conformity with Council Directive 2006 95 EC is based on EN IEC 61010 1 2001 Safety requirements for electrical equipment for measurement control and laboratory use and that conformity with Council Directive 2004 108 EC is based on EN IEC 61326 1 2006 EMC requirements for electrical equipment for measurement control and laboratory use tae cel By David C Graef Vice President and
27. ow the surface to dry completely before returning the instrument to service Use and Maintenance The LogicStudio16 is a high quality precision instrument To maintain accuracy and signal fidelity mechanical shock should be avoided as well as damage to the cables through excessive bending All maintenance and component replacement should be referred to qualified personnel 7 919183 RevA Visit digikey com Getting Started Manual Software and Driver Installation The most recent LogicStudio installer is available as a zip file from the LeCroy website at www lecroy com e Choose to Save the zip file to a location on your local computer e When the zip file is completely downloaded to your machine double click the file to open its contents Two files and two folders should be shown e Double click the file named Setup exe to launch the installer The installer guides you through proper setup of both the LogicStudio software and necessary drivers for your computer as explained in the following topics Software Installation Welcome to the LogicStudio Setup Wizard 4 P 7 A35 1 3 78 The installer will guide you through the steps required to install Logic S tudio on your computer This will also install drivers for the supported devices Do not connect these devices until the installation has been successtully completed WARNING This computer program 1 protected by copyright law and international treaties Unauthorized dupli
28. own Ed logs5tudo Dema l File Devices Setup Help IME PT setup FSignals Minstr Trigger 25m SS t st_ slat 317773 ME ea rn ES 3 un s 7 3 r B 4 r u LogicSstuctto Navigation The user can navigate the Waveform Display Area and make various view adjustments using the following controls e Panning the Timeframe Left click and drag left right and the waveform display area moves in the direction you ve chosen e Zoom a Specific Region Hold Control left click and drag left right When the mouse button is released your zoom is shown in the waveform display area e Scale the Timeframe Click and Drag Right click and drag left right to scale the timeframe and view zoom in out around the center point of the view OR e Scale the Timeframe Mousewheel You can alternatively scale the timeframe using the mousewheel by putting your mouse pointer anywhere inside the waveform display area and mousewheeling up down instead of right clicking and dragging left right Mousewheeling advances in 10 increments Note Along with these navigation tools you can also double click any area on the waveform display area to automatically center the view at the point of your selection 919183 RevA 14 Visit digikey com LogicStudio Scale and Grid A timescale is displayed along the top edge of the waveform display area at all times The scale steps and labels dynamically adjust based on the curren
29. ram is provided right on the Scope Finder window Oscilloscope Models Supported by LogicStudio LECROY Support for LeCroy WaveJet oscilloscopes is included with the LogicStudio installation No additional software is needed The following oscilloscopes are supported e Wavelet 300A Series AGILENT Support for Agilent oscilloscopes requires a VISA implementation installed on the PC you re using Agilent IOLibSuite software includes their VISA implementation and can be obtained from the software included with the oscilloscope or from the Agilent website at www agilent com The following oscilloscopes are supported e DSO5000A Series e DSO6000A Series e DSO7000A and 7000B Series TEKTRONIX Support for Tektronix oscilloscopes requires a VISA implementation installed on the PC you re using Tektronix TEKVISA software is their VISA implementation and can be obtained from the software included with your oscilloscope or from the Tektronix website at www tek com The following oscilloscopes are supported e DPO2000 and MSO2000 Series e DPO3000 and MSO3000 Series e DPO4000 and MSO4000 Series e TDS 1000B Series e TDS 2000B and TDS2000C Series e TDS 3000C Series PLEASE NOTE THE FOLLOWING e When using TDS oscilloscopes ensure the Rear USB Port setting on the instrument is set to Computer This setting is made pressing the Utility button on the oscilloscope and selecting Options e Attime per division settings of 100ns div and faster
30. s An example of an I C trigger is shown here Simple Logic Trigger on 12C Bus V Protocol I2C 7 bit addressing mode PREGES o al Direction REAA WHEE REGNE address a Fomat rex JF 0111010 Length 2 Y Bytes L lle Format ASCII F 01001100 01100101 01000011 01110010 EXTERNAL TAB Use this tab to set the logic pod to trigger on an external input signal A threshold voltage for the signal can be specified Sample Rate The Sample Rate spinner control is located at the top of the dashboard just to the right of the Setup buttons It shows the selected rate of sampling for the digital pod Use the up down arrow buttons at the right of the control to cycle through the higher lower sample rates available on the device Changes made on the Sample Rate take effect on subsequent acquisitions 27 919183 RevA Visit digikey com Getting Started Manual The Menu Bar The Menu Bar is a series of pull down listings along the top of the application screen These pull down listings provide access to some additional features and alternative ways use some aforementioned functions and controls Save Load Setup Acquisition or Screenshot Save Load functions are accessed under File on the menu bar Save Load Setup Located under File gt Save Load Setup on the menu bar this function lets you save your current configuration to a file or load a previously saved file back into LogicStudio This incl
31. t timeframe shown Labeled tick marks have dashed grid lines extending the full height of the display providing waveform reference I ll 3 15ms a TF l 40 Interacting with Cursors Cursors are easily applied to the waveform display area see The Cursors Tool topic for more information Tools Controls for LogicStudio s built in Tools are located in the space above the Waveform Display Area The built in tools include controls for Cursors RearView and Magnifier respectively Es Toggle the Cursors and Magnifier tools RearView is always on on or off by clicking the main portion of the control containing the icon Click the right side of the control to access detailed controls related to each tool The Cursors Tool This topic demonstrates the use of the Cursors tool ma F rd oge gt When the Cursor tool is enabled you are currently armed with the selected cursor pair on the waveform display When expanded the tool s detailed control provides storage for up to 4 cursor pairs When cursors are placed on the display they are highlighted when the pair is selected from the numbered cursor pair Remove a pair by clicking the Remove Cursor button on the right side of the numbered cursor pair Cursors are controlled and interacted with in the following ways e Selecting a cursor pair button activates the pair e Pressing the Remove Cursor button for the pair deletes them from the display
32. the TDS1000 and TDS2000 series oscilloscopes interpolate points between samples This makes the available timeline shorter with no increased resolution and is not recommended for use with LogicStudio as it may cause your trigger event to be outside the acquired oscilloscope timeline 919183 RevA 30 Visit digikey com LogicStudio Simulate Devices Toggle this option to switch demo mode on off When in demo mode no real devices are necessary and pre generated data can be acquired from a simulated digital pod and oscilloscope Aside from triggering and threshold settings most LogicStudio features are fully functional and behave exactly as they would for real devices Setup Setup functions are accessed under Setup on the menu bar The setup menu provides alternative access to Signals Instrument and Trigger setup windows identical to the buttons on the dashboard The Mixed Signal Setup Dialog Located under Setup gt Mixed Signal on the menu bar this function shows the Mixed Signal Setup Dialog where you can specify in nanoseconds an analog trigger alignment correction value This setting can be used to fine tune analog data acquired from the oscilloscope to the data from the digital pod for example to compensate if a different length of cross trigger cable is used Positive values shift the analog trigger point later in time and make the analog data move earlier in time relative to the digital data on the Waveform Display Area
33. tly present or has been explicitly disconnected by the user You cannot make new acquisitions without a connection to a digital pod However you do not need to have an oscilloscope connected to create acquisitions PLEASE NOTE THE FOLLOWING e Toggling this button connects and disconnects the last connected oscilloscope If no last connected oscilloscope is in memory the Scope Finder window is shown e Manually disabling or disconnecting the oscilloscope can speed up the rate of acquisitions if you temporarily don t need the analog data e Refer to the Oscilloscope Models Supported by topic for a list of supported oscilloscopes Pin Activity The Pin Activity display is located at the top of the dashboard It shows the activity status of all digital device channels in real time regardless of application or device state Setup Three Setup buttons are directly to the right of the device connection buttons The Setup buttons allow for configuring the application and digital device sau Sora Te RG 919183 RevA 24 LogicStudio Signals List Clicking the Signals button shows a screen containing a list of all signals to be rendered on the waveform display The Signal listing looks like the following AP Se z Type Doinne F J Radix L BOSE Se Digital Line F Radix Name p OOOO Color Type SPI Decode P Radix Hex E Name SPI Bus Color 15 12 11 0 MEAR
34. udes all configurations of signals device settings triggering and view state Default Setup Located under File gt Default Setup on the menu bar this function resets the application setup to the default configuration The default setup contains 16 simple digital line signals DO D15 Save Load Acquisition Located under File gt Save Load Acquisition on the menu bar this function allows you to save the complete set of samples digital and or analog included in your currently displayed acquisition When using the RearView tool the currently selected acquisition is saved The resulting acquisition file can then be re opened in LogicStudio for further examination or sent to another LogicStudio user along with your Setup configuration for additional analysis Data loaded into LogicStudio can be manipulated and displayed exactly the same as when it s acquired live Note All raw samples are saved This means you can reconfigure your signals after reloading an acquisition file to view different channel in new ways Save Screenshot Located under File gt Save Screenshot on the menu bar this function provides an easy way for the user to capture a screenshot of the application in its current state and save it to a specified location Your screenshot can be saved into most standard image formats Send Files Located under File gt Send Files To on the menu bar this function allows for easily sharing your current data and