Home
User`s Manual
Contents
1. Please enter your name the name of the company for which you work and the product serial number User Name Bicker Company Name Bicker Serial Number Enter the respective data The Serial Number is printed on the CD cover You have provided the Following registration information Mame Benutzer Name ff User name Company Firmenname ff Customer Mame Serial Number Is this registration information correct When all data have been entered correctly click Yes to continue www bicker de info bicker de 35 Bicker Elektronik GmbH Tel 49 0 906 70595 0 InstallShield Wizard Choose Destination Location Select folder where Setup will install files Setup will install RUPS 2000 in the following folder To install to this folder click Next To install to a different folder click Browse and select another folder Destination Folder D Program Files Megatec RUPS 2000 Browse InstallShield Select directory and click Next InstallShield Wizard Select Program Folder Please select a program folder Setup will add program icons to the Program Folder listed below You may type a new folder name or select one from the existing folders list Click Next to continue Progra UPS 2000 ATI Hydra ision ATI Multimedia Center Autostart Avery Zweckform WinLabel Bauknecht Softfolio CamStudio Canon iR1200 1300 InstallShield Click Next
2. InstallShield Wizard Setup Status RUPS 2000 Setup is performing the requested operations Installing C 4 99D 98244 71E4 4870 44D04 D1FABC694959 datal cab Installshield The data are copied into the directory 36 Bicker Elektronik GmbH Tel 49 0 906 70595 0 www bicker de info bicker de InstallShield Wizard InstallShield Wizard Complete The InstallShield Wizard has successfully installed RUPS 2000 Click Finish to exit the wizard b Yes want to register the product now Set the checkmarks as required and click Finish InstallShield Wizard Enter Text Please enter information in the field below Benutzer Namell User namel Firmennamel Customer N Select from list E When the software is registered all fields incl Serial Number Installshield must be filled in InstallShield Wizard InstallShield Wizard Complete The InstallShield Wizard has successfully installed RUPS 2000 Before you can use the program you must restart your computer No will restart my computer later Remove any disks from their drives and then click Finish to complete setup Completion Then click Finish Bicker Elektronik GmbH Tel 49 0 906 70595 0 www bicker de info bicker de 37 gez Shortcut to i_view32 MM Acronis SON MSN E Games fan Startup RUPS Daemon Windows Media Playe Internet Explorer wa MsN 33 Windows Messenger
3. Medizintechnik Benutzerhandbuch User s Manual mNSP3 450P USB A Industrie PC Netzteile I Netzteile 1 DC DC Wandler I USV Systeme rm een ee en EO EEE Ga EO bia daa eea Eee gt o Ee ze AR oa tore ee meee pe Ea gt e at ale a Eee baa Zra ONT eo 1 General E Contents of Delivery 1 2 Optional Accessories 2 Technical Data 3 Software Installation 3 1 USB Driver for mNSP3 450P USB 32 RUPS 2000 B1 UPS Management Software a UPS Service of Windows 2000 XP 4 Connections 4 1 External 42 Internal ENSP USB INT 5 ENSP3 REBOOT Automatic Startup PC board 6 Health and Safety Warnings 7 Troubleshooting Bicker Elektronik GmbH Tel 49 0 906 70595 0 www bicker de info bicker de 27 DEICKER de EKTRONI 1 General Congratulations for choosing the mNSP3 450P USB This manual explains the components and properties of the medical PC power supply All information contained in this manual has been revised thoroughly to ensure accuracy and completeness Yet Bicker Electronic accepts no liability for any omissions or faults We will appreciate any notifications regarding faults suggestions for improvements and criticism 1 1 Contents of Delivery Please check immediately upon reception of the mNSP3 450P USB whether the delivery is damaged in any way for which packing damage may be an indication The contents of delivery are m Medical PC Power Supply mNSP3 450P USB
4. Cable harness 1 2 Optional Accessories m BP 2423N battery pack with lead batteries 24 V 2 3 Ah m RBSO2A P24 2 3L battery pack with lead batteries removable clip on frame m BS10A H24 2 0L battery pack with NiMH batteries 24 V 2 0 Ah m RUPS 2000 B1 UPS Management Software m ENSP3 REBOOT Automatic Startup PC board m ENSP3 USB INT internal USB interface holder 2 Technical Data II Please download the current datasheets from our homepage m mNSP3 450P USB mE BP 2423N m RBSO2A P24 2 3L E BS10A H24 2 0L RUPS 2000 B1 28 Bicker Elektronik GmbH Tel 49 0 906 70595 0 www bicker de info bicker de 3 Software Installation 3 1 USB Driver for mNSP3 450P USB Please load down the driver from www bicker de directly at the product mNSP3 450P USB If you are using the PDF version of the manual please click on the picture below mNSP3 450P USB 300 Watt Medical applications PC power supplies Product details Product data PC PSU for medical applications with UPS function Various battery packs With USB interface ES D D E be USB Driver File Edit View Favorites Tools Help Q pek Q B P Search I Folders E ddress PO G USB Driver Technical documentation TZ Data Sheet pdf 0 8 MB CD uss driver niprbus sU Us driver_ 768 01 Extract the driver to a directory of your choice using e g Winzip or a similar program 1 Found New Hardware x P2102 US
5. 5 Outlook Express TEE e Remote Assistance windows Media Player a Notepad 3 Windows Messenger Y Windows Movie Maker All Programs EO RUPS 2000 A Log Off o Turn Off Computer The RUPS 2000 can be started without previous restart of the PC Rups Service is stopped i Start the service now Click Yes E EE mt In the main menu select Settings 38 Bicker Elektronik GmbH Tel 49 0 906 70595 0 www bicker de info bicker de Settings General E Mail Pager Shutdown Warning UPS connected at Serial Port v Remote Configuration Password Select the COM Port in rider General Settings After AC failure commence computer fo i di shutdown sequence in 0 2880 min 10 E Mins If Low Battery occurs commence shutdown i sequence in 0 600 min 1 Es Mins IV Auto save application files Execute command file Max 5 mins MV Turm off UPS IV Display last saved information when Startup Use the rider Shutdown to set the back up time Switch off UPS must not be set 7 8 Y Settings Pop Up Warning Message every 10 600 sec E 3 Secs r Notified Message AC Power Failed Attention Utility Power Failure AC Power Restored Utiity Power Restored UPS Battery Low Attention UPS Battery Low Battery Low Recovered JuPs Recovered from Low Battery Use the rider Warnings to adjust the on screen messages prompted by
6. IBM Lan Server Artisoft LANtastic Load CD Enter the menu N Menu RUPS for Win 95 98 NT 2000 Me XP 2003 Vista RUPS for Linuxv3 11 GE d RUPS for Novell NetWare RUPS v3 231 for MS DOS RUPS 13 231 for W Select Install Programm in the menu InstallShield Wizard Welcome to the InstallShield Wizard for RUPS 2000 The InstallShield Wizard will install RUPS 2000 on your computer To continue click Next E Cancel Click Next 34 Bicker ElektronikGmbH Tel 49 0 906 70595 0 www bicker de info bicker de InstallShield Wizard License Agreement Please read the following license agreement carefully Press the PAGE DOWN key to see the rest of the agreement LIMITED WARRANTY THE PROGRAM AND ENCLOSED MATERIALS ARE PROVIDED AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANT ABILITY AND FITNESS FOR 4 PARTICULAR PURPOSE THE ENTIRE RISK AS TO QUALITY AND PERFORMANCE OF THE PROGRAM AND ENCLOSED MATERIAL IS ASSUMED BY YOU LIMITATION OF REMEDIES Mega System Technologies entire liability and your exclusion remedy shall be replacement Do you accept all the terms of the preceding License Agreement If you choose No the setup will close To install RUPS 2000 you must accept this agreement nstallShield No Click Yes InstallShield Wizard Customer Information Please enter your information
7. Wizard Please choose your search and installation options Search for the best driver in these locations Use the check boxes below to limit or expand the default search which includes local paths and removable media The best driver found will be installed Search removable media floppy CD ROM Include this location in the search G AUSB Driver O Dont search will choose the driver to install Choose this option to select the device driver from a list Windows does not guarantee that the driver you choose will be the best match for your hardware Select the required source and click Next 30 Bicker Elektronik GmbH Tel 49 0 906 70595 0 www bicker de info bicker de Found New Hardware Wizard Please wait while the wizard searches 2 CP2102 USB to UART Bridge Controller Wizard searches driver Hardware Installation A The software you are installing for this hardware e Nipron USB Port has not passed Windows Logo testing to verify its compatibility with Windows XP Tell me why this testing is important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing Continue Anyway Click Continue Anyway Found New Ha
8. B to UART Bridge Controller Connect the USB cable at the PSU and PC Bicker Elektronik GmbH Tel 49 0 906 70595 0 File and Folder Tasks GO Make a new Folder 2 Publish this Folder to the Web KO Share this folder A Other Places pe USB_DISK G ES My Documents O Shared Documents Setup Information 8 KB Window niprunin u98 U98 File 1k B niprwdm Setup Information BKE www bicker de niprunin niprunin u2k U2K File 1KB niprw2k etup Information 5 KB BO E onfiguration Settings 1 KB info bicker de Found New Hardware Wizard Welcome to the Found New Hardware Wizard Windows will search for current and updated software by looking on your computer on the hardware installation CD or on the Windows Update Web site with your permission Read our privacy policy Can windows connect to Windows Update to search for software iy O Yes now and every time connect a device O No not this time Click Next to continue The Welcome screen is Bad displayed Click Next Found New Hardware Wizard This wizard helps you install software for CP2102 USB to UART Bridge Controller If your hardware came with an installation CD SEP or floppy disk insert it now What do you want the wizard to do O Install the software automatically Recommended Click Next to continue Make the required settings and click Next Found New Hardware
9. ck must only be opened by a qualified electri cal technician Danger of short circuit Electrostatic discharge may damage the components of the computer Install the components in an ESD protected area If such a working environment is not available please wear an antistatic wristband Do not burn the batteries Tel 49 0 906 70595 0 www bicker de info bicker de 49 ELE R N I e a KTR 7 Troubleshooting Failure Possible cause Possible countermeasure Failure Possible cause Possible countermeasure Failure Possible cause Possible countermeasure Failure Possible cause Possible countermeasure Failure Possible cause Possible countermeasure 50 Bicker Elektronik GmbH No function 1 Mains switch is switched off 2 Cable at PSU and PC is loose 1 Switch on mains switch 2 Check cable at PSU and PC for tightness No UPS function 1 No battery pack is connected 2 Battery pack has not enough capacitance or is discharged 1 Connect battery pack 2 Charge battery pack or replace it No software communication 1 Wrong COM Port is set 2 No USB driver is installed for mNSP3 450P USB 1 Adjust COM Port 2 Install driver PC switches off in UPS operation 1 The back up time in the UPS software was set too high 2 Battery pack has not enough capacitance or is discharged 1 Check back up time 2 Check battery pack PC does not s
10. e UPS Service can be accessed via System Control under Energy Options Power Options Properties Power Schemes Advanced Hibemate UPS Uninterruptible Power Supply Current power source ka Estimated UPS runtime Estimated UPS capacity Battery condition El Manufacturer None EZ Modet In the rider UPS click the Select button UPS Selection Custom Choose Standard Customized and COM Port then click Next UPS Interface Configuration On COM1 UPS Signal Polarity Make the required settings Setting Shut down via UPS is not compulsory Then click Finish 42 Bicker ElektronikGmbH Tel 49 0 906 70595 0 www bicker de info bicker de Power Options Properties Power Schemes Advanced Hibernate UPS Uninterruptible Power Supply Status Current power source i Estimated UPS runtime Estimated UPS capacity Battery condition Manufacturer Generic Model Custom JJ To commit the new settings choose OK or Apply Abou Click the Configuration button UPS Configuration Critical alarm Make the desired settings Click OK and Accept Power Options Properties Power Schemes Advanced Hibemate UPS Uninterruptible Power Supply Status Ga Current power source On Battery Estimated UPS runtime Estimated UPS capacity Battery condition Manufacturer Generic Model Custom The PC will shut d
11. own after the given time Bicker Elektronik GmbH Tel 49 0 906 70595 0 www bicker de info bicker de 43 gt BICKER de ELEKTR N I 4 Connections 4 1 External The power supply is connected from the backside to the mainboard via an USB cable 44 Bicker ElektronikGmbH Tel 49 0 906 70595 0 www bicker de info bicker de 4 2 Internal ENSP USB INT The following figures illustrate the connection procedure with USB cable Dismount USB module and install dummy plate Mount USB module into the aluminium bracket and connect to the internal SIG connector Mount aluminium bracket and install into PC casing Connect internal USB cable to mainboard Bicker Elektronik GmbH Tel 49 0 906 70595 0 www bicker de info bicker de 45 USB Connection Please compare the pin assign ment of the internal USB cable to the pin assignment of your mainboard WARNING The pin assignments must comply A polarity reversal may damage the USB module as well as the mainboard Example from a mainboard manual USB intern 1 intern 2 intern 3 intern 4 46 Bicker Elektronik GmbH Tel 49 0 906 70595 0 www bicker de info bicker de 5 ENSP3 REBOOT Automatic Startup PC board The PCB supports the following operational modes Starting the PC as soon as mains power is supplied m Rebooting the PC or Windows in case mains power returns while Windows is shutting do
12. rdware Wizard Please wait while the wizard installs the software Nipron USB Port DA E Setting a system restore point and backing up old files in case your system needs to be restored in the future Cancel Software installation Bicker Elektronik GmbH Tel 49 0 906 70595 0 www bicker de info bicker de 31 Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for e Nipron USB Port Click Finish to close the wizard Back Cance Glick Finish S A Search BE Folders SOL ES Control Panel v Go Control Panel A d ZE Accessibility Add Hardware Administrative Automatic Date and Time Switch to Category View Options i Tools Updates Display Folder Options Fonts Game Internet Keyboard windows Update Controllers Options pe Also Help and Support e gt sa B gt E ES Mouse Network Network Setup Phone and Power Options Printers and Connections Wizard Modem Faxes e 3 O BD 02 g Regional and Scanners and Scheduled Security Sounds and Speech Language Cameras Tasks Center Audio Devices ZU lt a Taskbar and User Accounts Windows wireless Start Menu Firewall Network Set At Control Panel select System System Properties System Restore Automatic Updates Remote General Computer Name Hardware Advanced Device Manager The Device Manager lists all the hardware devices ins
13. talled on your computer Use the Device Manager to change the properties of any device Device Manager Drivers E Driver Signing lets you make sure that installed drivers are A compatible with Windows Windows Update lets you set up how Windows connects to Windows Update for drivers Hardware Profiles E Hardware profiles provide a way for you to set up and store different hardware configurations Hardware Profiles Open the Device Manager 32 Bicker ElektronikGmbH Tel 49 0 906 70595 0 www bicker de info bicker de Es Device Manager E 2 Computer ms Disk drives Display adapters 1 2 DVD CD ROM drives EGA Floppy disk controllers Floppy disk drives 8 IDE ATAJATAPI controllers H Keyboards Mice and other pointing devices Monitors 2 Other devices Y Ports COM amp LPT i Communications Port COM1 The USB Port will be displayed Y Commurications Port Coma Y ECP Printer Port LPT1 as vi Filla CO M Po rt po Nipron USB Port COM3 EE Processors It can now be used with the ee SZ EA Sound video and game controllers UPS module of Windows Se Storage volumes or the RUPS 2000 software Bicker Elektronik GmbH Tel 49 0 906 70595 0 www bicker de info bicker de 33 J BICKER de ELEKT N I 3 2 RUPS 2000 B1 This software supports the following OS Novell NetWare Linux LAN Manager Windows 3 x 95 98 NT ME 2000 2003 XP Vista 7
14. the system in case of power failure Bicker Elektronik GmbH Tel 49 0 906 70595 0 www bicker de info bicker de 39 Settings Modem connected at m Notified Pager Number Event Pager Number Code To Send AC Power failed AC Power restored UPS Battery Low Battery Low Recovered IV Send Notification to the same pager number Settings for Pager A modem is required Settings sender Disply Name Sender Email ddress SMTP Server Address Server Require Authentication otified Email Address Power abnormal condition E mail settings An e mail system is required 27 Disconnect mains plug simula tion of power failure The PC will shut down after the set time and switch off 40 Bicker Elektronik GmbH Tel 49 0 906 70595 0 www bickerde COM2 info bicker de AC Failure Zz AC Power Restored AC Failure AC Power Restored AC Failure z AC Power Restored Error messages can be read out from a list Event Log ESI Mon I Tue wed Thus I Fi Pz ala BCE fs pel fo ER ERED IZE EI EA peje PRO EN EST 2008 03 Days with failure occurrences will be marked in the calendar Under Closed File Records the closed programmes are listed Bicker Elektronik GmbH Tel 49 0 906 70595 0 www bicker de info bicker de 41 QQ BICKER de ELEKTRONIK User s Manual mNSP3 450P USB 3 3 UPS Service of Windows 2000 XP Th
15. witch off after Windows shutdown 1 ACPI function is not activated 2 Is a wrong interface cable installed 1 Activate ACPI function in BIOS and operating system 2 Check interface cable Tel 49 0 906 70595 0 www bicker de info bicker de Notizen Notes Bicker Elektronik GmbH Tel 49 0 906 70595 0 www bicker de info bicker de 51 I Industrial PC PSUs I Power supplies I Medical applications 2 DC DC converters I UPS systems O BICKER de ELEKTRONIK Bicker Elektronik GmbH Ludwig Auer Stra e 23 86609 Donauw rth Germany Tel 49 0 906 70595 0 Fax 49 0 906 70595 55 E Mail info bicker de Internet www bicker de Irrt mer und technische nderungen vorbehalten Windows ist ein eingetragenes Warenzeichen der Firma Microsoft Corp Stand 12 11 2009 All data are subject to change without notice Windows is a registered trademark of Microsoft Corporation Statusas at November 12 2009
16. wn Note This is not possible via PC BIOS settings Contents of the ENSP3 REBOOT m Automatic Startup PC board cables crimp connectors spacers Installation or retrofit Mount the spacers to the PCB Install PCB into casing Bicker Elektronik GmbH Tel 49 0 906 70595 0 www bicker de info bicker de 47 The following connections have to be made at the PCB Connect the red and black twisted cable to 5 V and the purple and black twisted cable to 5 VS Observe polarity Then connect the open ends to the ATX cable harness red red purple purple black black Connect the start button of the PC to OUT2 and connect the included black and white cable to the multi pin connector start button on the motherboard Connect the remaining connector to OUTI Crimp Connector Power Supply PD GE multi pin wel edate eo OO oo pe pe pa pe pe HE pe pa pe pe pe pe pe HH HN be pe HH HE bea A pe pe pe N pe pe pe pe pe pe a jo O Start Button Multi pin connector 48 Bicker Elektronik GmbH Tel 49 0 906 70595 0 www bicker de info bicker de Connect the open ends to the ATX cable harness red red purple purple black black 6 Health and Safety Warnings Bicker Elektronik GmbH Warning danger of electric shock and ESD For any work at the unit the battery connector as well as the mains connector must be disconnected The power supply does not contain any maintenance parts The battery pa