Home
Multi Media Cable Tester TM-901N/TM-902/TM-903
Contents
1. Pe LI qr EE Aene nd 1 Displays graph wiremap opens shorts miswires split pairs Displays Length and Unit Lower battery indication Enter the SETUP mode symbol Result displays Pass AN Split Displays remote ID number BON TE N MARS TM 901N TM 902 TM 903 5 Multi Media Cable Tester Features TENMARS TM 903 MultiMedia Cable Tester TM 903 D 1 Power Key 7 RJ 45 connector socket 2 Setup function right 8 F Connector TM 903 Key 9 RJ 11 connector 3 Setting Key and Unit socket TM 903 select Key 10 Remote ID locator 4 Test Key and Enter 11 RJ 45 connector socket Key of remote ID locator 5 Setup function left 12 Tilt stand Key 13 Battery cover 6 Length and wiremap and signal tone function key TE N MARS TM 901N TM 902 TM 903 6 Testing Twisted Pair Cabling 1 Connect the meter and remote ID locator to the cabling as shown in Figures 2 Pressthe key to power on TM 902 903 3 Press key to measures wiremap and Remote ID Locators detect 4 Display show some testing option as shown in Figures ID 0000000 11 11 FI 11 11 lI id 3545 18 TENMARS TM 901N TM 902 TM 903 7 Twisted Pair Test Results The following figures show typical test results for twisted pair cabling Any
2. x The spilt pair detects of cable must be at least 5 meter 15ft in length x If open short and miswires anyone occur the spilt pair detects will don t work TENMARS TM 901N TM 902 TM 903 8 Length measures 1 Press the key to power on 2 Press the L W key TM 901N TM 902 or 7 key TM 903 to switch to Length TM 903 3 Press and Key to select show length pairs 1 4 4 Inthe display length Press the key to changing the length units shown in Figure LENGTH mac TE NMARS TM 901N TM 902 TM 903 9 1 2 SIGNALTONE measures TM 903 Press the key to power on Press the 8 key to switch to SIGNALTONE Press the 17 Key to select a different tone sequence displayed as the numbers 1 4 on LCD The function default continuity LCD display C If you want to changing press the Key to select continuity LCD display C to changing one shot LCD display F you can selection numbers 1 8 Press the key to enable or disable out signal tone is cable tracing function Toner is cable tracing function that assists in tracking cables hidden in walls Ceilings floors or patch panels by generating four distinct multi tone signals that can be 10 TENMARS TM 901N TM 902 TM 903 received by a cable tracer To trace a cable 10 Using Multiple Remote ID Locators Using multiple remote ID locators helps you identify multiple network cable connections as shown in Figure
3. 10 The display in Figure shows that the verifier is connected to the cable terminated with remote ID locator number 3 11 TE NMARS TM 901N TM 902 TM 903 11 Auto power on and off setting mode 1 Press the key to power on 2 Press the key for more than 2 Second to enter Setting mode into setting mode 3 Press key again to auto power on or off setting 4 Press the T or key to change ON or OFF 5 Press key to enter and exit setting mode shown in Figure 12 TE N MARS TM 90 1N TM 902 TM 903 12 Backlight on or off setting mode Press the key to power Press the 781 key for more than 2 second to enter Setting mode into setting mode Press the gt key setting to auto power on or off setting Press the key to backlight set Press the setting mod Press the T key to change ON or OFF key again to backlight Press the key to enter and exit setting mode shown in Figure 13 TE NMARS TM 901N TM 902 TM 903 13 Changing Memory Number Default Category Types UTP STP Calibrating Length Measurements Value Parameter Options The meter to provide user self calibrate memory use number 1 9 User can order different cable type category and length to acquire measurements value parameter 1 Press key to power on 2 Press the key more than 2 second to and setting mode 3 Press the T key setting to auto power
4. The TM 902 TM 903 Multimedia Cable Tester TM 901N LAN Cable Tester is a hand held test instrument that lets you verify and troubleshoot the Lan cable of twisted pair 2 Safety Precaution A CAUTION A following conditions while measuring Do not operate the meter under the environment with explosive gas material combustible gas material steam or filled with dust e In order to avoid reading incorrect data please replace the battery immediately when the symbol appears on the LCD e In order to avoid the damage caused by contamination or static electricity do not touch the circuit board before you take any adequate action e Operating Environment Indoors use This instrument has been designed for being 1 TE NMARS TM 901N TM 902 TM 903 used in an environment of pollution degree 2 Operation Altitude Up to 2000M EMC EN61326 1 2006 IEC 61000 4 2 2008 IEC 61000 4 3 2006 2007 The verifier does the following Detects opens shorts miswires and split pairs on twisted pair cabling Displays graph wiremap opens shorts miswires split pairs and the remote ID number all on one screen Identify remote ID number only one pair Measures length Using multiple remote ID up to 8 locators Low battery detector E Auto backlight Auto power off TENMARS TM 901N TM 902 TM 903 4 Display Features 6 SIGNALTONE nn eee meme Uns
5. error occurs will show AN symbol on LCD Opens Figure shows an open pair wire 4 and 5 J M WIREMAP 5 lt 18 123595 18 i TENMARS TM 901N TM 902 TM 903 Shorts Figure shows tow short between wires 3 4 and 5 another 1 and 8 _ 103545185 Ni X When shorted occur the verifier mavbe not show open and miswires Miswires Figure shows that wires 3 and 4 are crossed The pin numbers order to indicate the fault TENMARS TM 901N TM 902 TM 903 Split Pair The following figure shows a split pair on 3 6 and 4 5 The split pair flashes to indicate the fault LCD will show SPLIT indicate In a split pair continuity from end to end is correct but is made with wires from different pairs Split pairs cause excessive crosstalk that interferes with network operation eae te WIREMAP IC JU 62 EV ES 0 0101 55 Zs il 1 page split pair wiring IC JU IJ 1 an split pair wiring
6. on or off setting Press the 4 kev to backlight set Press and gt key to select number zero from No 0 9 Press key again to setting flashes number Press 4 and key to select number zero from SET Snit 1 No 0 9 Press key to enter exit setting mode SET 4 Press key into setting flashes cable 14 TCNMARS TM 901N TM 902 TM 903 category Press ang gt key to setting cat 5 or cat 6 RJ11 COAX TM 903 5 Press key gt flashes cable type 6 Press key to select UTP or STP again to setting TEST Press key to enter exit setting mode shown in Figure 7 Press the key more than 2 second to and setting mode Press the gt key again to select setting flashes calibrating length measurements value parameter 8 Press and key to select known length measurements value parameter 15 TE NMARS TM 901N TM 902 TM 903 9 Press key to enter and exit setting mode shown in Figure 14 Checking the LCD and Software Version In the shutoff mode Press and hold 1 key again press the o key to turn on meter and LCD will keep all dark continued 16 TE N MARS TM 901N TM 902 TM 903 15 Battery Replacement Turn off the meter and disconnect all test leads before replacing the battery Use only the correct type of batteries properly installed in the case to power the meter WARNING If the symbol E appears on the LCD please repl
7. TENMARS Multi Media Cable Tester TM 901N TM 902 TM 903 User Manual TENMARS TM 903 MultiMedia Cable Tester HB2TM9020010 TENMARS ELECTRONICS CO LTD NOOO BR WD 10 11 12 13 14 15 16 17 18 Table of Contents ae 1 Safety Precaution 1 The verifier does the following 2 Display 3 Multi Media Cable Tester Features 4 Testing Twisted Pair Cabling 5 Twisted Pair Test Results 6 ODENS t 6 SONS uc e uli sep d tai 7 MISWIFGS sein an a 7 scene 8 Length 9 SIGNALTONE measures TM 903 10 Using Multiple Remote ID Locators 11 Auto power on and off setting mode 12 Backlight on or off setting mode 13 Changing Memory Number Default Category Types UTP STP Calibrating Length Measurements Value Parameter Options 14 Checking the LCD and Software Version 16 Battery Replacement 17 Options and Accessories 17 ENG OF Merrni 17 specifications rena nne can 18 TE N MARS TM 901N TM 902 TM 903 1 Introduction
8. ace the battery immediately 16 Options and Accessories Consumers can order options and accessories as follows Remote ID Locator Kit numbers 2 8 17 End of life Caution this symbol indicates that equipment and its accessories shall be subject to a separate collection and E correct disposal 17 TE NMARS TM 901N TM 902 TM 903 18 Specifications e Cable types tested UTP STP e Cable Category tested CAT5 CAT6 RJ 11 COAX TM 903 only e Test connectors Shielded 8 pin modular jack RJ45 test voice cable RJ11 TM 903 and video coax cable F connenector TM 903 e Wiremap test Detects opens shorts miswires split pairs e Length test Range up to 255 m 836 ft Resolution 0 1 m ft Unit meter and foot Typical accuracy 10 1 0m 3 ft e Display 58mm L x45mm W Monochrome LCD with backlight e Battery 1 5Vx6 batteries LRO3 SIZE AAA 1 5V e Battery Lift Approx continuous testing 200 times 18 TENMARS TM 901N TM 902 TM 903 e Shutoff Rate Power 1uA e Operate Maximum Power 20mA e Operating temperature and humidity 5 Cto 40 C below 80 RH e Storage temperature and humidity 10 to 60C below 70 e Dimensions 156 L 73 W 35 H mm e Weight About 170g e Accessories User s manual x1 1 5V AAA battery x6 CAT5 STP Cable x1 remote ID 1 x1 19 TENMARS lt gt Professional Electrical and Environment Test amp Measurement Instruments Battery Capaci
9. ty Impedance Tester LED light meter Temperature amp Humidity meter Infrared Thermometer Sound level meter Light meter EMF meter UV Light meter RF meter Hot wire Anemometer CO meter Anemometer Lan cable tester meter Solar power meter Radiation meter Clamp meter Multimeter Phase Rotation test Digital Insulation tester Our products of high quality are selling well all over the world TENMARS ELECTRONICS CO LTD 6F 586 RUI GUANG ROAD NEIHU TAIPEI 114 TAIWAN E mail service tenmars com http www tenmars com
Download Pdf Manuals