Home

Live and breathe

image

Contents

1. Basic Revi Technical Data Weight with cylinder jacket and maximum equipment n Pressure reducer OXYWAY Fine OXYWAY Fine Dimensions W x H x D in mm 119 239 x 94 x 100 Weight 7309 High pressure manual connection G 3 4 Connection bolt 80 mm right 100 mm right Nominal inlet pressure 200 bar Nominal outlet pressure 0 5 6 0 bar Outlet G 3 8 Flow 3 15 l min MPG device class ll b Fulfilled norms EN 738 1 Bubble humidifier Filling amount 100 ml distilled water Fulfilled norms EN ISO 8185 1 OMNIVAC secretion aspiration equipment Oxygen consumption 13 min at least 0 5 bar 500 ml and 1000 ml EN ISO 10079 3 Vacuum generated Collection canister Fulfilled norms COMBIBAG MPG device class lla Dimensions length x diam 340 x 130 mm inflated Weight 390 g Application Child grip 10 16 kg body weight Adult grip gt 16 kg body weight PONY carriage 650 x 650 x 900 H 1050 mm with cylinder jacket Dimensions L x W x H in mm Weight about 3 2 kg with cylinder jacket about 4 6 kg Allowable angle of inclination max 10 Allowable load max 100 kg Oxygen cylinder Contents 10 Maximum pressure 200 bar Weight 16 kg filled Oxygen administrator with three outlets Fulfilled norms DIN EN 737 CE 0197 Connection bolts of different lengths and with different connection thread types are available OXYFLOW Basic and OXYFLOW Revi are also av
2. Operating panel with display and menu selection with navigation button Accessory Systems The right accessories can contribute greatly to successful therapy That s why Weinmann offers accessories that add to the functions of the basic products Home ventilation devices for example work with VENTIc ick an easy to adapt high performance heated humiditier that can hold up to 300 ml of water It is specially designed for patients who require high levels of humidification and high flow For patients who need additional oxygen Weinmann offers the oxygen valve VENTI O2 which provides an increased inlet pressure for use in the hospital or at home With the help of the battery pack VENTIpower the entire ventilation system can operate for up to five hours in the event of a power loss or when used away from home The ventilation software VENTIsupport is used for the clear visualization continuous monitoring and exact analysis of patient compliance data Technical Data see chapter TD7 WEINM ANN medicalMtechnology Home Mechanical Ventilation Humidification During treatment many NIV patients suffer from dried out mucous membranes which can often lead to painful inflammation and nosebleeds As a result patients frequently refuse to accept the therapy and the use of their devices Weinmann s heated humiditiers VENTIclick SOMNOclick and SOMNOwave can help those patients They are easily attached to the therapy devices and adjusted
3. better air tightness User friendly m Easy to use m Easy to fit Technical Data see chapter TD12 Patient Interface E JOYCE Full Face Rear view n keeping with our proven modular design all parts except the mask seal are identical to those of JOYCE Full Face SOMNOplus SOMNOmask of SOMNOmask blue Comfortable Ball and socket joint guarantees freedom of movement ISO cone adaptation to all available exhalation systems m Kind to the skin mask doesn t stick to face WEINMANN medical Mtechnology E Patient Interface HEADstrap Just one single headgear for all patients Therapeutic success or failure is determined to a great extent by ventilation masks as they provide the most sensitive of all interface functions in a patient s therapy The overall wearing comfort of a ventilation mask depends on how well the mask fits how easy it is to use and how comfortably the fasteners fit HEADstrap our new head gear for masks fulfills all these requirements The four point headgear crosses the back of the patient s head In contrast to conventional headgear HEADstrap ensures that no pres sure is applied to the patient s neck HEADstrap is suitable for every head size and is very easy to use The slits through which the straps slide permit nearly limitless adjustment The Strap across the back of the head can be fitted to any head size quickly and easily HEADstrap The headge
4. Microsoft Windows XP starting with SP1 Microsoft Windows 95 98 ME NT4 0 2000 XP Internet Explorer 5 01 or higher Operating System Other Software ADO database driver MDAC 2 1 or higher Microsoft Word 97 2000 XP is not a part of Internet Explorer 6 or higher Acrobat Reader starting with Version 5 Microsoft Word starting with Version 2000 Technical Data Weight Dimensions W x H x D Product class as per 93 42 EEC Classification as per EN 60601 1 Protection from electric shock Degree of prot from elec shock Service life Power supply Power consumption Loudspeaker Charging time Reserve battery pack in MULTIBASE 2 PC interface 9 V batteries Measurement method Tested in accordance to Operating temperature Storage temperature Humidity Measurement range Precision Alarms Signal Displays Batteries Storage Data port 1 hPa 1 mbar Systems supported MULTIBASE 2 about 500 g without accessories 165 x 165 x 65 mm lla protection class II type BF power supply plug 230 V 12 V or 12 V service cable for vehicular power supply about 3 W 7 W for print operation 100 mW infinitely adjustable O to about 70 dB A battery pack in measurement device 16 hrs reserve battery pack in MULTIBASE 2 2 hrs 2 hrs RS 232 SubD 9 pin 0 C to 45 C 0 90 no condensation amplification of acoustic alarms issued by CAPNOCOUNT mini and OXYC
5. Patient Interface Central element in successful therapy Masks are the most problematic part of therapy After all they touch and cover a large part of the patient s face one of the most sensitive areas of the body for several hours during the day or night If the mask doesn t fit well it may cause pressure points on the face or it may leak Those problems could prompt the patient to reject the mask and thus jeopardize the success of his therapy Despite these concerns masks were until recently just a side issue in the area of ventilation Increasingly however they have been moving toward the center of attention as many patients have evidently realized that the success of therapy depends in large part on the mask The mask is the interface between man and machine and the way to get the air from the therapy device via a hose into the patient s airways The requirements for ventilation masks most of which are nasal or full face masks are enormously high For one thing they should be comfortable and skin friendly At the same time they should sit snugly on all different face types so that they can t slip out of place during the night and cause leaks But they shouldn t be too tight or else they ll leave painful pressure points behind Beyond that the masks have to be able to withstand high therapy pressures and provide a way for patients to exhale without too much effort They also have to be quiet and easy to use Certified Qua
6. 180 x 90 x 320 mm about 3 4 kg 5 C to 35 C 20 C to 70 C 115 230 V AC 50 60 Hz or 12 24 V DC with converter In order to guarantee the pressure consistency SOMNO balance e lla 210 x 90 x 270 mm about 1 7 kg 5 C to 35 C 40 C to 70 C 115 230 V AC 50 60 Hz with power supply WM 24480 or 12 24 V DC with DC Adapter required in HMV a maximum voltage WM 24469 drop of 10 is allowed operation standby 0 1A 0 02 A 0 2 A 0 03 A 1 5 A 0 6 A operation storage 0 1 A 0 02 A 0 2 A 0 03 A STA 0 6 A protection from electric shock protection class Il degree of protection from electric shock type B approx 27 dB A at 10 hPa EN 55011 EN 61000 4 parts 2 to 6 part 11 approx 26 dB A at 10 hPa approx 27 dB A at 10 hPa 600 1100 hPa automatic altitude adjustment 600 corresponds to 4000 meters at 9 hPa Ap 0 4 hPa CPAP 4 20 hPa precision 1 hPa CPAP 9 hPa 125 l min at 12hPa Ap 0 4 hPa CPAP 4 18 hPa precision 0 4 hPa CPAP with softPAP yes 12 hPa 130 l min at 9 hPa Ap 0 5 hPa 95 relative humidity no condensation CPAP APAP 4 20 hPa precision 1 hPa CPAP APAP each with softPAP 9 hPa 150 l min up to 1 um 99 5 up to 0 3 um gt 85 gt 250 hours with normal room air SOMNOsmart 2 lla 180 x 90 x 320 mm about 3 6 kg 5 C to 35 C 20 C to 70 C 115 230 V AC 50 60 Hz or 12 24 V DC with converter WM
7. Ap lt 0 5 hPa gt 99 7 1000 hrs in normal ambient air lt 95 relative humidity no condensation therapy device with hose system WM 24130 and Silentflow WM 23600 1 hPa VENTImotion with O hose system WM 23737 VENTIclick VENTImotion with hose system WM 24130 and BiLevel ST 22 with O hose system WM 24130 and Silentflow WM 23600 Silentflow WM WM 24365 23600 and bacteria filter WM 24148 0 19 kPa s 0 19 kPa s 0 29 kPa s 0 20 kPa s Safe distance as a function of transmission frequency in meters Safe distance as a function of transmission frequency in meters 150 KHz 80 MHz 800 MHz 150 KHz 80 MHz 800 MHz to to to to to to 80 MHz 800 MHz 2 5 GHz 80 MHz 800 MHz 2 5 GHz 0 12 0 12 0 24 0 04 0 04 0 08 0 37 0 37 0 74 0 11 0 11 0 22 1 17 1 17 2 34 0 35 0 35 0 70 3 69 3 69 7 38 1 10 1 10 2 20 11 67 11 67 23 33 3 50 3 50 7 00 WEINM medical NN technology TD8 Technical Data Home Mechanical Ventilation Technical Data Product class as per 93 42 EEC Dimensions W x H x D Weight Battery pack type Battery pack operating time Battery pack usable life Temperature range Air presssure range Pneumatic connection Electrical connection Current consumption in operation Electrical output Classification as per EN 60601 1 Water resistance Electromagnetic compatibility as per EN 60601 1 2 Radio interference suppression Radio interference resistance Ope
8. Remote setting with SOMNOadjust or SOMNOsupport leakages etc plus compliance data therapy calendar Analog signals for PSG input flow pressure leakage softPAP Anticipatory pressure relief the sleep therapy device SOMNOsoft functions according to the softPAP principle It is especially designed for sensitive patients who do not like the feeling of exhaling against high CPAP pressure Depending on the patient s needs two different pressure reduction levels can be set in softPAP mode for the transition from inspiration to expiration Because the patient can exhale more easily his sleep is more restful and his compliance with therapy is better The CPAP pressure is reduced only if no impending respiratory events such as apnea or flow limitations are detected Thus it is guar anteed that the airways will always be kept open The device also automatically adjusts to the patient s own respiratory pattern and prevents tachypnea abnormally fast breathing Because there is no flow proportional change in the pressure reduction the patient s breathing is supported in the event of central hypopnea softPAP Pressure Relief Anticipatory reduction at end inspiratory phase Gentle relieved exhalation from the start pressure hPa Renewed increase in pressure adjusted to patient s respiratory rate Airways kept open at critical points IN EX respiratory cycle Technical Data see chapter TD4 WEINM ANN medical Mtech
9. orange Pin 5 12 V yellow Pin 6 ERROR green PIN 7 POWER FAIL blue PIN 8 SENSE violet 5 LEDs in 20 steps display error as per calibration cycle lt 5 100 LED 95 capacity 80 LED 75 capacity 60 LED 55 capacity 40 LED 35 capacity 20 LED 15 capacity 100 LED 85 capacity 80 LED 65 capacity 60 LED 45 capacity 40 LED 25 capacity 20 LED 5 capacity Analogbox D A with BiLevel ST 22 Channel Messure value Channel 1 mask pressure Channel 2 flow Channel 3 leckage flow Channel 4 tidal volumes Channel 5 unassigned Channel 6 unassigned Channel 7 unassigned Channel 8 unassigned 1 hPa21 mbar Scaling OV 1V O hPa 25 hPa 100 l min 300 l min O l min 300 l min O mil 3000 ml Data apply only in combination with the approved therapy devices Technical Data Home Mechanical Ventilation VENTIpower charger Technical Data Dimensions W x H x D 135 x 185 x 83 mm Weight about 0 8 kg Input voltage 85 240 V DC 50 60 Hz automatic internal voltage switch Charging current 2A Max voltage at connections 42 V Classification in accordance with EN degree of protection from electric shock type B 60601 1 protection from electric shock protection class Il Electromagnetic compatibility in radio interference suppression EN 55011 VDE 0875 part 11 accordance with EN 60601 1 2 radio interference resistance EN 61000 4 parts 2 to 6 Converter box Converter cable U
10. 70 C at 50 l min 0 25 hPa at 100 l min 0 92 hPa 6 to 12 months depending on frequency of use and cleaning mask body polycarbonate PC mask seal silicone LSR Connection sleeve Therapy pressure range Weight Temperature range Flow resistance elbow connection polycarbonate PC seal for ports silicone LSR forehead cushion silicone LSR support polypropylene PP Sound pressure level at 10 hPa Usable life All parts of the nasal mask are latex free Silentflow 2 lla Materials cone in compliance with DIN EN ISO 5356 1 22 mm 9 21 5 mm 1 Cone suitable for hoses of elastomer with an inner connector with 20 21 mm 4 40 hPa 159 operation 5 C to 40 C storage 20 C to 70 C at 50 l min 0 04 hPa at 100 l min 0 18 hPa 28 dB A 6 months 12 months with good care depending on frequency of use and cleaning polycarbonate PC Maximum humidity in hose sultable for connection to conical connector with a diameter of 22 mm in conformance with DIN EN ISO 5356 1 Y 22 7 mm 1 external cone suitable for elastomeric hoses with a connection diameter of 20 to 22 mm 4 40 hPa 20g operation 5 C to 40 C storage 20 C to 70 C 95 rel humidity no condensation at 50 l min 0 07 hPa at 100 l min 0 25 hPa 23 4 dB A 3 months with conscientious care 6 months depending on frequency of use and cleaning sleeve polycarbonate PC c
11. A2 SONMNO er o E A2 SONINOcheckenion e E a A 3 SOMINO ae eee o ra te ees en eae ees A3 ARTISANA SoftWare S eee ee A5 SOMNO manager Software cooccccccccccncccnnnnnnnnnno namas A7 OX YCOUNTTAI ears tees pee eee ee eee en A8 GAP NO GOW A ee renee OS A8 SIT CI OX A A A8 Introduction sa a a E a a B1 SOMNOcomfort 2e CPAP20e B2 OMNO SO fete scene A A B3 SOMNO Balance e aa a la O ee B4 SOMNOS Ma 2 e a a aio B5 SOMNO vent CR a code B6 SOMNOvent S SOMNO vent ST B8 SOMNO Si otters A tae E Re B9 SOMNOsupport Software B 11 Device Components and Accessories B 12 Home Mechanical Ventilation a Introduction O ne ee C1 WENT O gica o e RR C2 VENTO ton a ae dea IEoS ana C4 BibevelSN2o area ain tenet Pee E ie Perera aero een C6 Device Components and Accessories C8 VENTI support Software tenniet i C 10 WEINM ANN medicalMtechnology Table of Contents Lo IDA Oxygen Medicine o ON D 1 ODED 3 je carona ae tease hae reese cranes mete cee see naere D2 A A a DE SRU qua cane meat D2 DITRON Sa re ees tate tee eae cd D3 CYPRESS oa eee eee eee oe Melee D3 OX VFLOW estes cece E eee A ADO dns A D4 OX BA GP eee e a D4 OY IVAN A ram antec oe er E ean ene nee D5 ACCUVAC Basica tias oon eee ects eee eee D5 S Inc rans por Ba O es SR E D 6 Device Components and Accessories D7 e UG CLOW a a RARE E 1 E na A A a he E 2 Me JOYCE minar dao ee ae une a at Se
12. Operation and storage IBM compatible compute Graphics card Processor Pentium II 700 MHz or better Microsoft Windows supported Free storage Hard disk with at least 300 resolution eae is MB free storage space and 50 MB free max resolution 1600x1200 storage space in system partition Input Keyboard and mouse or other Active memory Suitable pointing device supported by at least 128 MB RAM recommended Microsoft Windows 512 MB RAM Printer supported by MS Windows Se ee eer res Connection Operating system eae mrad A Operation and storage 0 95 non condensing For operating the converter box Windows 2000 SP4 or better E E eibilit WM 93316 Windows XP SP2 or better Sl according to EN 60601 1 2 Radio interference suppression EN 55011 VDE 0875 T11 Radio interference resistance EN 61000 4 Parts 2 to 5 A free Microsoft Windows supported with software Internet Explorer 6 0 SP1 RS232 serial port COM1 to COM4 or better Adobe Acrobat Reader 6 0 16550 compatible UART or a USB Recommended system port with a USB to RS232 adapter We recommend a Pentium Ill processor EN 55011 EN 61000 4 Parts 2 to 6 11 For operating converter cable USBRS485 WM 93318 A free USB port Drive CD ROM drive WEINM ANN medical Mtechnology with a clock rate of at least 1 GHz 512 MB RAM and a 17 VGA monitor Technical Data Home Mechanical Ventilation Technical Data
13. Simple operation flow levels are easily set and checked and cylinders are connected manually All relevant safety standards are fulfilled High variability on device outlet e g straight or angled connection nozzle disposable or reusable humidifier suction injector oxygen administrator country specific standard couplings m Mobile Weinmann service available as additional option m Maintenance every four years OXYWAY pressure reducers come in four basic models OXYWAY Fast OXYWAY Fix OXYWAY Fine and OXYWAY Click ACCUVAC Basic Safe suction at home and away from home ACCUVAC Basic can be adjusted for any suction situation in home care usage including pediatrics thanks to Its infinitely variable subpressure regulation The feature laden suction pump is tough and tilt resistant Accessories make the ACCUVAC Basic especially versatile mobile via its integrated battery pack in a vehicle via the 12 volt cable and at home via a separate mains power supply unit Performance features High patient safety level with subpressure regulation from 0 05 to 0 8 bar via a rotary dial and additional subpressure regulation via suction hose with fingertip control m Suitable for use in pediatrics Flow capacity gt 20 liters minute at 0 8 bar subpressure Available with disposable collection canister integrated overflow valve or with autoclavable reusable collection canister additional integrated bacteria filter
14. Support and promotion of new ideas We re also very much interested in young scientists who have attracted attention through their commitment ideas and innovations We show our interest by awarding the Weinmann prize which is designed to promote promising scientists working in sleep research and medicine and by presenting additional grants to support those scientists at many national and international symposiums and congresses Our demands for the best possible quality make their way through all areas of our business At Weinmann new me dical products are subjected to a standardized certified validation process by Quality Management prior to their launch The validation tests guarantee the products efficiency and quality Only then can a product become a useful part e g a component in a sleep lab of a complete solution Everything from a single source lasting quality as cost advantage This type of cooperative effort is most successful when both product development and product maintenance are in the hands of one party Then you can be sure that all parts of the system share the same level of quality That s an important condition for working efficiently and achieving the best results making the right diagnosis and provid ing successful therapy WEINM NN medicalMtechnology WELCOME WEI NM AN N We the employees of Weinmann family owned and operated berin madieal Fio Enolagy in the field of medical tech
15. Versatile m Modular system Accessories quick release cord m Mask seal 30 hPa 40 hPa Elbow E vented transparent includes anti asphyxia valve E non vented blue Three variations in four sizes S M L and new XL each for varying purposes m JOYCE Full Face vented incl exhalation system and soft mask seal up to 30 hPa OSAS E JOYCE Full Face 40 hPa vented incl exhalation system and hard mask seal up to 40 hPa m JOYCE Full Face NV 40 hPa non vented without exhalation system and hard mask seal up to 40 hPa ventilation Comfortable m Proven ball and socket joint A choice of two mask seals for low and medium therapy pressure up to 30 hPa for high therapy pressure of up to 40 hPa m Optional integrated exhalation system Four standard models in four sizes S M L and new XL each packed ready to use Mask seal is simply pressed into place with palm of hand Extra small shape Extremely quiet m Anatomically molded skin friendly mask seal Breathable headgear with practical clip hooks Adjustable forehead support wide cushion Stopper for pressure measurement connection Easy care The mask can be completely disassembled and cleaned in the dishwasher Technical Data see chapter TD12 Patient Interface E JOYCE GEL JOYCE Full Face GEL Only from Weinmann Nasal AND Full Face Gel Masks JOYCE the proven mask for every sleep apnea and home mechanical ve
16. and TD12 1 Home Mechanical Ventilation Software VENTIsupport Better overview VENTIsupport is the supplemental PC software for home venti lation devices by Weinmann The software reads out visualizes and analyzes therapy monitoring data With the help of daily statistics the patient s ventilation data can be analyzed breath for breath for a 10 hour period Furthermore the statistical analysis also permits numeric and graphic representation of all ventilation parameters in Weinmann s home ventilation devices for up to six weeks Annual compliance shows the patient s use of the device for 365 days With its remote setting module VENTladjust VENTIsupport lets the user display and set therapy parameters With the ventilation software VENTIsupport patient compliance can be visualized graphically checked continuously and analyzed accurately JULU UU JL uU nia gj jip g ops Ml Tle ARAALI A M Pl Lii D Aia ada iad tein tational o na AD A pel oe e all EJ F MJ au 4 E mJ EJ Mi E mi oa r d did SL md ds EPE EES ma VENTIsupport A 2 Ese Pz Analysis phase and transition to se mas as ae ventilation in TA mode le ELE O m a VENTIsupport Statistical data on patient unloading in TA mode Starting December 2007 WEINMANNsupport one package for everything An integrated PC software package
17. at any time with a mouse click Sequences can be cut out easily and archived with recorded data SOMNO ab software supports the following devices SOMNO ab Head Body and Transterbox SOMNOcheck 2 SOMNOcheck 2 R amp K Reports With the push of a button you can generate brief or de tailed reports in tabular or graphic form Templates available as part of the supply schedule simplify work with the Report Generator ITOT ee BOT 31130 Might wigar Patient Lam revi 4 Fira rara F Coma or birt 1707 Ma Simple pre configured analysis reports Patient management It s easy to manage and archive measurement and patient data with use of the integrated SOMNOmanager lite soft ware D us nes eie m JM DEN et mmc Ba dr 4 B eie i na a a mii ee Al mA mg Vu DECO re Pd AA A EO Bd Tl a ad Cites OA NE Dira 1 AA da BEARN IMA AA FA NE a e or fF Ls Do ea LES A PA H 00 wala De Pa ed Na aa IR dE A eu ro RO A LED E TT Mi 15004 ira Sada RIC MEA i do titer Lone thi ee LIGU ld korebe 1 E DD H A A Y Hd apii p Ep binii AT ee ES n Th ddein Tiemie G DE PH a HET wa List of epochs with easy to use sort and filter functions Technical Data see chapter TD2 WEINM ANN medical Mtechnology ARTISANA Professional analysis at the press of a button in your SOMNO ab system When you analyze your recordings with the new sleep apnea software ARTISANA you ll get ve
18. m Made user friendly by practical features such as a front mounted integrated hose holder battery pack voltage indicator and side mountable accessories bag Technical Data see chapter TD11 Oxygen Medicine DS i9 OXYWAY Fast for gradually adjustable doses of oxygen flow in levels 1 2 BA 5 6 9 12 15 lter min te or 0 5 1 15 2 26 amp 40 Se liters minute OXYWAY Fix for permanently set oxygen flow of 4 liters minute or 120 liters minute for MEDUMAT OXYWAY Fine for infinitely adjustable oxygen flow of 0 5 3 1 5 8 3 15 liters minute with content and flow meter OXYWAY Click tor flow dosage via central gas systems used by rescue services and hospitals Each basic device has additional models for special uses Country specific connectors are also available upon request 0 d CCUVAC i Mai ACCUVAC Basic with accessories bag and reusable collection canister Flexibly applicable thanks to integrated battery pack wall bracket with integrated battery charger optional 12 V connection cable for use in motor vehicle optional mains charger unit with wide area input for charging and operating in mains network optional m Low noise level Ergonomic design for simple care and cleaning WEINMANN medical Mtechnology D6 Oxygen Medicine Accessories 3 in 1 Transport Bag For all mobile oxygen therapy systems by Weinmann The 3 in 1 Transport Bag is suitable for all O
19. minutes m Two level filter system Safe oxygen feed m Automatic altitude adjustment External power pack can be used worldwide with 100 240 V DC adapter for 12 V 24 V available as accessory Available option Humidifier CLICK 2 Attaches to therapy device with a simple click holds 280 ml of water six level setting on therapy device easy to clean Technical Data see chapter TD4 Sleep Therapy KER SOMNOsoft EM CPAP therapy with softPAP SOMNOsoft is the new sleep apnea therapy device with gentle and intelligent pressure relief in softPAP mode The device reduces the maximum CPAP pressure in anticipation of the change to exhalation but like CPAP safely and effectively maintains the pressure during inhalation First class sleep New and sensitive patients in particular sleep more comfortably exhale more gently and enjoy a more restful night Doctors have a broader therapy spectrum and patients improve their therapy compliance Extremely quiet with high pressure constancy Comfortable with softstart and autostart m Simple device operation Highly developed hygiene concept m Two level filter system with fine and coarse filters Adaptable heated humidifier SOMNOclick 300 SOMNOsoft with softPAP pressure relief m Graphic analysis with PC software SOMNOsupport and extensive diagnostic information for therapy monitoring RDI respiratory events snoring relative respiratory minute volumes
20. of measured value 0 4 5 Vol 0 2 Vol 5 1 9 9 Vol 5 of measured value time required to meet specification about 2 mins apnea alarm etCO high low AF high low occlusion alarm red LED etCO in mmHg or Vol respiratory rate cont CO in bar chart alarm limits change battery pack text display LCD with green backlighting red LED alarm 9 V long life alkaline battery etCO and respiratory rate every 2 seconds time at start and end of measurement capacity of 8 hrs data buffer during battery change RS 232 to communicate with MULTIBASE 2 smartOx about 72 g with batteries 32 x 136 x 24 mm ll b protection class Il type BF IEC 601 0 C to 45 C 20 C to 70 C 0 90 no condensation SpO 45 100 pulse rate 20 to 300 bpm saturation 2 70 100 pulse rate 1 bpm to 100 bpm 1 gt 100 bpm acoustic and visual signals pulse rate sensor status system error and battery status Signal on off pulse tone variable tone pitch depen ding on the measured O saturation LCD with white backlighting and red orange and green LEDs display of SpO pulse rate bar chart signal quality battery and sensor status 2 x AAA alkaline batteries gt 20 hours of continuous measurement WEINM medical NN technology Technical Data Sleep Therapy Technical Data Product class as per 93 42 EEC Dimensions WxHxD Weight Temperature range m
21. oxygen concentration monitoring by an inte grat ed oxygen sensor Reaches maximum oxygen concentration in less than three minutes m Highest safety level for patient provided by visual and acoustic alarm functions O concentration positive and negative pressure Three year warranty on all functional parts Also suitable for operation at 60Hz Reset button for protection from voltage peaks Adjustable rollers and practical service flap for fine filter change Technical Data see chapter TD10 OXYTRON 3 Versatile oxygen conserving system for greater mobility On the road with the electronic oxygen conserving device OXYTRON 3 the patient is supplied with an oxygen dosage based on his her need with every breath Because the OXYTRON 3 has a longer cylinder range of up to five times the average an oxygen patient can once again go for a walk visit friends or go shopping and reduce his oxygen expense at the same time OXYTRON 3 can be used with pressurized gas cylinders or liquid oxygen systems Performance features Low maintenance electronic oxygen conserving system with separate pressure reducer Also suitable for liquid oxygen systems Significant oxygen savings at 5 1 as compared to continu ous flow systems but with the same therapeutic effect Precise dosage of oxygen at seven levels from 10 to 70 ml per breath m High level of patient safety ensured by a very sensitive trigger uninterrupted battery
22. polysomnograph s data and the device intrinsic curves The job of the Analogbox is to convert the digital information into analog signals The box which measures about 10 centimeters wide and 15 centimeters high is equipped with four interfaces with double configuration These interfaces connect the ventilator to the polysomnograph and permit the simultaneous display of parameter signals and ventilation curves on a single screen VENTI click More humidity VENTIclick the heated humidifier with 300 ml water capacity and increased humidifying performance can be attached to the device with just a click Specially designed for patients who need increased humidity at higher flows VENTI ogic with VENTI click VENTI click VENTIpower More safety More mobility If the power fails or the patient leaves home the complete ventilation system can be operated by a battery pack except for BiLevel ST 22 for at least five hours The patient simply places the device in the convenient transport bag and continues VENTIpower with ventilation while away from home _VENTImotion in transport bag JOYCE JOYCE Full Face SOMNOplus Nasal mask Full face mask All in one Mask exhalation system headgear SOMNOmask Exhalation systems Bacteria filter Nasal mask Silentflow 2 and noise suppressor E My Details about mask systems in chapter E NN technology WEINM medical Technical Data see chapter TD8 9
23. smartOx Pulse rate and oxygen saturation available immediately New measurement technology and an extremely convenient design team up to provide an efficient solution for spot checks and pre and post operative short term monitoring smartOx Technical Data see chapter TD3 WEINM ANN medicalMtechnology Sleep Therapy Fast recovery through positive pressure ventilation In order to function effectively during the day an organism has to regenerate by sleeping through the night There are some diseases like sleep related respiratory disorders sleep apnea that prevent regeneration Repeated respiratory arrests lasting at least 10 seconds each rob the affected person of restful and recuperative sleep The many effects show up in daytime sleepiness heart problems high blood pressure and reduced efficiency Many decades ago Weinmann became the first German company to develop therapeutic solutions individually tailored to the needs of those patients Among the solutions is the nightly administration of positive pressure ventilation during sleep a treatment that quickly improves the patient s condition By means of a therapy device and mask the patient receives continuous positive pressure throughout the night By providing a splint CPAP Continuous Positive Airway Pressure makes sure that the patient s airways cannot collapse There are other forms of therapy in addition to classic CPAP therapy AutoCPAP gently adapt
24. status display and visual and acoustic alarm functions Easy to use push button operation easy to read display and easy to handle low weight device Power sources practical rechargeable battery pack with brief charging time less than two hours device can be operated while it is being charged or disposable batteries Available with different cylinder sizes 2 0 liter 0 8 liter 2 0 liter lightweight aluminum cylinder and transport sys tems 3 in 1 transport bag caddy CYPRESS Pneumatic oxygen conserving system and pressure reducer CYPRESS is an oxygen conserving system designed according to the two in one principle The pneumatically operated oxygen conserver is combined with an oxygen pressure reducer Like conventional pressure reducers CYPRESS is simply screwed onto the oxygen cylinder and the dosage is set on the handy rotary dial That s it Performance features m Maintenance free pneumatic oxygen conserver with integrated pressure reducer Can be used with all oxygen cylinders up to a maximum of 200 bar m Significant oxygen savings 3 1 in comparison with continuous flow systems with same therapeutic effect m Precise oxygen dosages in six levels from 16 to 96 ml per breath Simple operation rotary dial for dosages continuous flow and off modes and integrated pressure reducer m Greater patient comfort made possible by small and compact design and low weight about 560 grams including pressure redu
25. to 100 l min lt 36 hPa lt 36 hPa lt 30 hPa hy AG Signals respiratory events and compliance data Data apply only in combination with the approved therapy devices WEINM medical NN technology Technical Data Sleep Therapy Technical Data Product class as per 93 42 EEC Dimensions Weight Temperature range Electrical connection Electrical output Classification as per EN 60601 1 Protection from electric shock Degree of protection from electric shock Electromagnetic compatibility as per EN 60601 1 2 Radio interference suppression Radio interference resistance Mean sound pressure level operation as per EN ISO 17510 from patient position at distance of one meter from device Air pressure range Therapy pressure range Maximum amount allowed Max operating pressure allowed Max flow flowing off freely allowed Max mask temperature Inner volume of bacteria filter Usage time of particle filter Gas leakage at 30 hPa Electrical connection Current consumption at 230 V at 115 V at 12 V Min required O primary pressure at valve opening for 4 l min O Max allowable dynamic pressure of O system Allowable therapy pressures Pressure drop at a flow of 50 l min at a flow of 100 l min at a flow of 150 l min Housing material Autoclavable housing in devices as per EN 285 User setting which results in 100 rel humidity at
26. trouble accepting the device s ventilation rhythm The SX and SXX modes help to stabilize the patient s breathing pattern Convenient therapy m Undisturbed optimum ventilation by simulating patient s own respiratory pattern m Whisper quiet at only 25 dB A Softstart also available in T and ST modes m Analysis can be manually started in physician mode as needed Parameter setting in TA curve of analyzed TA mode patient flow and applied ventilation flow Support for device service m No readjustment of parameter settings when patient breathing changes High patient compliance due to optimum ventilation comfort combined with minimum operating expenditure Compatibility with all VENTI and SOMNO accessories and all conventional third party masks Display of patient activity Phase transition from Complete service by Weinmann customer service statistics in TA mode analysis to ventilation VENTI ogic with heated humidifier VENTIclick VENTI ogic in transport bag standard supply schedule and oxygen valve VENTI O WEINM ANN Technical Data see chapter TD7 medical technology Home Mechanical Ventilation VENTI motion At home or on the road optimum unloading of the respiratory pump The optimized home ventilation device VENTImotion relieves the patient s respiratory pump to the extent required by the patient s physiological condition The respiratory muscles can gradually relax and gain new stren
27. 24131 or WM 24132 in order to guarantee the pressure consistency required in HMV a maximum voltage drop of 10 is allowed operation standby 0 1 A 0 002 A 0 2 A 0 03 A 1 9 A 0 6 A approx 26 dB A at 10 hPa at 12 hPa Ap 0 4 hPa APAP 4 18 hPa precision 0 4 hPa APAP CPAP 12 hPa 150 l min Only for connection to SOMNOadjust WM 23930 and SOMNOsupport WM 23975 by authorized personnel or for control of lt 40 hPa NN technology O valve WM 24042 power consumption SOMNOagjust max 163 mA with SOMNOsmart 2 feed to PSG lt 40 hPa Two of following analog signals can be selected Pressure Flow Leakage lt 30 hPa Pes ian Two of following analog signals can be selected Pressure Flow Leakage OPP Obstructive Pressure Peak rAMV relatives respiratory minute volume lt 40 hPa Two of following analog signals can be selected Pressure Flow Leakage OPS Oscillatory Pressure Signal lt 30 hPa Signals respiratory events and compliance data Technical Data Product class as per 93 42 EEC Dimensions WxHxD Weight Temperature range m Operation E Storage Electrical connection Electrical output Current consumption at 230 V at 115 V at 12 V EN 60601 1 classification Electromagnetic compatibility EN 60601 1 2 Radio interfer suppression Radio interference resistance Mean sound pressure level opera
28. 4 5 0 2 0 5 6 4 5 0 2 z Flow Q1 in l min 0 5 0 13 10 5 10 5 10 5 10 25 20 5 2 0 5 2 0 5 1 5 0 25 320 5 320 5 30 5 2 0 25 4 0 5 4 0 5 4 0 5 4 0 2 120 15 3 15 1 5 8 0 5 3 2 5 0 25 50 5 5 20 5 50 5 30 25 6 0 6 6 0 6 6 0 6 4 0 50 9 0 9 9 0 9 9 0 9 5 0 50 12 1 2 12 1 2 12 1 2 6 0 50 15 1 5 1541 5 151 5 2nd outlet min 120 90 10 RA pressure relief valve 74 104 74 o Temperature Operation 20 C to 60 C Storage 20 C to 70 C Product class as per Il b la 93 42 EEC Fulfilled norms EN 738 1 EN 13220 OXYTRON 3 CYPRESS ACCUVAC Basic Technical Data Technical Data Product class as per 93 42 EEC lla lla Product class as per 93 42 EEC lb Dimensions W x Hx D 75 x 136 x 45 mm W x H 110 x 76 mm Fulfilled product norms EN ISO 10079 1 EN 1789 Weight about 330 g without pressure reducer 540 g including pressure reducer l incl battery pack Water resistance IPX 1 Stages 1 7 1 6 Dimensions W x H x D in mm 385 x 280 x 140 Oxygen dosage in ml 10 20 30 40 50 60 70 16 32 48 64 80 96 Weight about 5 4 kg Oxygen can anatiorirate in about 5 1 about 3 1 Ambient temperature operation 18 C to 40 C rela tion to continuous flow Continuous backup flow Pressure reducer 3 min via separate adapter separate OXYWAY Fix for OXYTRON 3 2 level 2 l min 0 5 l min integrated 3 4 DIN G charging O C to 40 C storage 40 C to 70 C permanently set
29. AC suction equipment with 500 ml and 1000 ml collection canisters and injector Holder for two collection canisters Respiration hose hi Connection nozzle with swivel nut Bubble humidifier ACCUVAC Basic Accessories Accessories bag Wall bracket Charger for charging only Mains charger unit operating and charging 12V connection cable Lead battery pack Conversion kit for disposable collection canister Conversion kit for reusable collection canister Application System Accessories for Oxygen Therapy Set of nasal cannula for babies with 2 1 meter connection hose 20 pcs 40 pcs Set of nasal cannula for children with 2 1 meter connection hose 20 pcs 40 pcs A Set of nasal cannula for adults with 2 1 meter connection hose 20 pcs 40 pcs 100 pcs Set of nasal cannula for adults with earpiece and 1 5 meter connection hose 20 pcs 40 pcs 100 pcs Set of nasal cannula for OXYTRON 3 20 pcs 40 pcs 100 pcs A E Inhalation masks for children without breathing bag Suction catheter Ch 10 with foam rubber pads and connection hose Set of inhalation masks for adults without breathing bag 6 pcs 12 pcs Set of suction catheters Ch 10 with foam rubber pads 10 pcs 20 pcs Set of inhalation masks for adults with breathing bag 6 pcs 12 pcs For other incidentals refer to current Weinmann price list WEINM ANN medical Mtechnology Patient Interface IN
30. OUNT mini SOMNOmanager SOMNO ab PC software SOMNOcheck 2 SOMNOsupport SOMNO ab OXYCOUNT mini about 160 g 65x 128 x27 mm lla protection class ll type BF about 30 hrs with NiMH battery pack 9 V long life alkaline battery or 7 2 V NiMH battery pack 100 mW without illumination 150 mW with illumination for pulse tone and alarms battery pack in measurement device 16 hrs about 24 hrs split pulse wave with fuzzy logic control EN 60601 1 prEN 865 0 C to 45 C 20 C to 70 C 0 90 SpO 0 99 pulse rate 30 250 bpm SpO gt 85 1 5 percentage points SpO 75 85 2 percentage points SpO 50 75 3 percentage points pulse rate 1 SpO pulse sensor error signal strength battery visual acoustic depending on alarm priorities LCD with green backlighting and red LED alarm 9 V long life alkaline battery data storage for SpO pulse rate and quality capacity of 7 hrs data buffer at least 30 mins during battery change RS 232 to communicate with MULTIBASE 2 CAPNOCOUNT mini about 320 g 65 x 128 x 35 mm lla protection class ll type BF about 3 hrs with rechargeable NiMH 9 V battery or 7 2 V battery pack NiMH 1 2W about 16 hrs about 30 mins IR photometric method EN 60601 1 prEN 864 5 C to 40 C 20 C to 70 C 0 95 no condensation etCO 3 75 mmHg or 0 4 9 9 Vol respiratory rate 2 60 bpm 1 bpm 3 38 mmHg 2 mmHg 39 75 mmHg 5
31. Ocheck 2 R amp K and SOMNOcheck 2 Source M Schwaibold Th Ploch W Cassel Th Penzel H F Becker Multicenter Study on the Variability of the Sleep Stage Scoring Algorithm ARTISANA Compared to Human Experts Part Il Validation Phase Abstract ERS 114s P793 2005 Applied rule available for each epoch via mouse click WEINM medical Mtechnology NN Sleep Diagnosis ESA SOMNO manager Weinmann s administrative software galar Weinmann software products can be delivered with soMNOmoncge SOMNOmanager lite upon request Mar SOMNO manager lite offers a patient database which requires only one time entry of patient data Diagnostic recordings made with SOMNOcheck 2 and SOMNO ab plus therapy monitoring data from SOMNOsupport are assigned to the patient after they have been read out of the diagnostic or therapy device SOMNO manager lite thus provides a complete overview of all examinations made of the patient Reports generated by the diagnostic software will likewise be filed in the database where they remain available at the click of a mouse In addition reports can be exported e filed in a dif ferent folder or sent by e mail b SOMNOmanager Lite 2 7 File Patient File Applications Views Configuration Omge i Patient Listing Waster data Bukowski Martin 4 30 1962 PIO Patient New 10131962 PIO ochlapp Stefan 6 7 1996 PID mee Ez Sch
32. Operation E Storage Electrical connection Current consumption at 230 V at 115 V at 12 V EN 60601 1 classification Electromagnetic compatibility EN 60601 1 2 Radio interfer suppression Radio interference resistance Mean sound pressure level operation as per EN ISO 17510 in patient position at distance of one meter from device Air pressure range Pressure constancy measured as per EN ISO 17510 Operation storage humidity Therapy pressure range Modes Softstart Flow at max speed at Fine filter separation level Fine filter service life Serial interface RS 485 Analog port 0 1 VDC Maximum marginal pressure for first error Heating of respiratory air as per EN ISO 17510 Signal feed 1 hPa 1 mbar WEINM medical CPAP20e lla 210 x 90 x 270 mm about 1 25 kg 5 C to 35 C 20 C to 70 C 115 230 V AC 10 15 50 60 Hz with power pack WM 24480 or 12 24 V DC 15 25 with DC adapter WM 24469 operation storage 0 1 A 0 02 A 0 2 A 0 03 A 1 6 A 0 24 A approx 30 dB A at 10 mbar at 10 hPa Ap 0 8 hPa CPAP 4 20 hPa precision 1 hPa CPAP 10 hPa 120 l min SOMNOcomfort 2e SOMNOsoft lla 210 x 90 x 270 mm about 1 7 kg 5 C to 35 C 40 C to 70 C 115 230 V AC 50 60 Hz with power supply WM 24480 or 12 24 V DC with DC Adapter WM 24469 operation storage 0 1A 0 02 A 0 2 A 0 03 A 1 8 A 0 24 A lla
33. Product class as per 93 42 EEC Dimensions W x H x D in mm Weight Temperature range Air pressure range Electrical connection Current consumption at 230 V at 115 V Classification according to EN 60601 1 Electromagnetic compatibility as per EN 60601 1 2 Radio interference suppression Radio interference resistance Mean sound pressure level operation as per EN ISO 17510 in patient position at distance of one meter from device Sound pressure level alarm IPAP pressure range EPAP pressure range CPAP pressure range Pressure precision Increment Minimum stable marginal pressure PLSmin min pressure in the event of a fault Maximum stable marginal pressure PLSmax max pressure in the event of a fault Respiratory rate Precision Increment I E ratio Trigger stage Pressure increase speed Pressure decrease speed Precision in volume measurement Flow at max speed at O hPa Flow at max speed with bacteria filter at O hPa Heating of respiratory air as required in HMV Pressure constancy measured as per DIN EN ISO 17510 in CPAP mode Fine filter separation level up to 2 um Fine filter service life Allowable humidity for operation and storage System resistance at air flow of 60 I min at patient connection port Recom3mended safe distances between portable high frequency telecommunications devices e g cellphones and data lines Nominal output of HF device i
34. SB RS485 Technical Data Device class EC 93 42 lla lla Dimensions WxHxD 135 x 55 x 30 mm 70 x 40 x 20 mm Length of USB cable 250 mm Weight approx 100 g approx 50 g Temperature range 10 C to 40 C Operation and storage Relative humidity Operation and storage 0 95 non condensing Electromagnetic compatibility according to EN 60601 1 2 Radio interference suppression EN 55011 VDE 0875 T11 EN 55011 Radio interference resistance EN 61000 4 Parts 2 to 5 EN 61000 4 Parts 2 to 6 11 VENTI support System requirements The VENTIsupport software requires an IBM Input keyboard and mouse or another compatible computer that satisfies the following suitable pointing device supported by requirements MS Windows Processor Pentium Ill 1 GHz or better Printer Free storage supported by MS Windows at least 300 MB on a hard drive at least Operating system 50 MB in system partition MS Windows 2000 Service Pack 4 Active memory MS Windows XP Service Pack 2 at least 128 MB RAM Software Adobe Acrobat Reader 6 0 Connection Internet Explorer 6 0 SP1 or better free RS232 serial interface COM1 to COM4 16550 compatible UART Recommended system Drive We recommend a Pentium IIl processor with a CD ROM drive at least 12x Graphics clock rate of at least 1 GHz 512 MB memory Ss eared and a 17 VGA monitor VGA resolution or higher color monitor min 1024x768 max 1600x1200 card sup
35. SG input flow pressure OPS leakage patients with high pressure needs or greater tidal volume Signals and Events airways PLETE iy Le AA A Variable depending on patient Inspiratory fl di AAA A AA AM A Variable depending on patient _ SM Pressure Signal OPS Esophageal pressure Oscillatory OH Obstructive Hypopnea OE1 Obstructive Event 1st degree Pos OA Obstructive Apnea OE2 Obstructive Event 2nd degree Technical Data see chapter TD4 WEINM ANN medical technology EX Sleep Therapy SOMNO vent CR Sound sleep clearly a matter of the heart SOMNOvent CR Cardio Respiratory is Weinmann s therapy device for patients with Cheyne Stokes respiration or central mixed or complex sleep apnea syndrome Anti cyclical modu lated ventilation ACMV also known as adaptive servo venti lation ASV normalizes the patient s breathing and eliminates related obstructions Waking reactions are reduced respira m Extremely quiet with high pressure constancy Comfortable with softstart and autostart Simple operation of device Well designed hygiene concept 2 level filter system with fine and coarse filters tion is stabilized and sleep is effectively improved SOMNOclick 300 humidifier can be adapted CR mode combined therapy for Cheyne Stokes respiration and sleep apnea m Maintenance only every two years or every 5000 ho
36. SO 8359 OXY control 2 Technical Data Fulfilled product norms EN 50104 Water resistance IP 64 Dimensions W x H x D mm 65 x 120 x 30 Weight about 240 g Ambient temperature operation storage Temperature compensation Humidity in operation Electrical power Measurement range Display resolution Precision Warm up time Electromagnetic compatibility O C to 50 C 20 C to 50 C built in NTC Compensation up to 99 9 V alkaline block battery 0 100 Vol O 0 1 O lt 13 sto 90 of end value radio interference suppression EN 55011 easyOX easyOX easyOX duo lla A20 x 630 x 400 about 28 kg 10 C to 40 C 20 C to 70 C 230 V 50 60 Hz 450 W 1 9 A line side T5 AL 250 V internal 8A 250 V 125 V protection class Il type B lt 45 dB A 95 1 3 Vol at 1 4 l min 90 3 3 Vol at 5 l min gt 82 Vol O at 5 l min 0 6 bar 60 kPa easyOX 0 5 at 5 l min easyOX duo each at 0 5 to 5 l min but only a total of 5 I min is available visual and acoustic radio interference suppression EN 55011 VDE 0875 part 11 radio interference resistance IEC 1000 4 parts 2 6 and 11 once per year after every 5000 operating hours available integrated oxygen sensor EN ISO 8359 max 1 from measurement range end value radio interference resistance EN 610006 2 1 hPa21 mbar 100 kPa 21 bar WEINM medical NN technology OXYFLOW OXYFLOW
37. XYTRON 3 CYPRESS and OXYBAG Hit sales variants available from Weinmann Equipped with individually adjustable belts the bag can be used as a backpack shoulder bag or in combina tion with the Weinmann caddy That means more flexibility for the pa tient and for the dealer who has to keep only one bag model in stock Features m Flexible use as backpack shoulder bag or on the caddy m For all mobile systems by Weinmann OXYTRON 3 CYPRESS OXYBAG Hit For use as a shoulder bag the bag s backpack belt can be stored easily Simple cleaning process For use as a backpack the shoulder bag belt can be remo Convenient extra inner bag with zipper for all accessories ved with just a click Small loop for storage Reinforced rear wall and bottom for higher patient safety Knobbed rubber base on bottom of bag for upright stability Technical Data see chapter TD11 WEINM ANN medical Mtechnology OXYMAT 3 easyOX Accessories OXY control 2 Oxygen concentration always under control The small and convenient device monitors oxygen concentra tion in Weinmann s oxygen concentrators OXYMAT 3 and easyOX Performance features Only two operating keys calibration key and on off key for simple use Very brief sensor response time for fast calibration and measurement High level of accuracy with 1 of measured value Device and accessories in protective transport case OXYMAT 3 Accessories Sepa
38. ached in just a few steps m No annoying cable connections SOMNO ab components Bodybox In just a few steps the bodybox is applied to the patient s abdomen With integrated pulse oximetry sensor respiratory flow snore sensor nasal cannula or pressure measure ment hose thorax and abdomen sensor with pulse oximeter and pressure and position sensors Headbox Applied to the patient s upper body connected to the neurological devices and sensors LEDs flash during the impedance test if the sensors have been connected incorrectly m Transferbox This is where all signals are collected and then transmitted via fiber optic cable or network connection to the computer Computer system Pre configured and equipped with Weinmann s system tested visualization and analysis software ensures enough computing capacity for configuration and operation on site Digicam The integrated video monitoring system can show the pa tient screen in screen next to his current analysis data The tiltable camera with zoom function can be adapted to any room SOMNObutler For convenient and neat storage of the transter box head box and bodybox and auxiliary materials during the day WEINM ANN medical Mtechnology NY Sleep Diagnosis Software SOMNO ab Software The user friendly way to measurement results SOMNO ab sottware is easy to set up according to individual needs and simple to use A number of automatic a
39. ailable with the pressure reducers OXYWAY Fine Il Fine Ill Fast Fast III OXYBAG Hit Technical Data Pressure reducer OXYWAY Fine Product class as per 93 42 EEC IIb Dimensions W x H x D in mm 119 x 94 x 100 Weight 7309 Nominal inlet pressure 200 bar Nominal outlet pressure 0 5 6 0 bar Flow 3 15 l min Standards fulfilled EN 738 1 CE 0197 Oxygen cylinder Contents 0 8 Maximum pressure 200 bar Weight filled 1 9 kg Oxygen cylinder Contents 2 01 Maximum pressure 200 bar Weight filled 3 6 kg Lightweight aluminum cylinder Contents 2 01 Maximum pressure 200 bar Weight filled 2 7 kg Connection bolts of different lengths and with different connection thread types are available OXYBAG Hit is also available with the pressure reducers OXYWAY Fine Il Fine Ill Fast Fast III Technical Data 14K Oxygen Medicine OXYWAY Fine OXYWAY Fast for infinitely adjustable oxygen flow dosage for gradually adjustable oxygen flow dosage OXYWAY Click Flow dosage for central gas systems OXYWAY Fix for permanently set oxygen flow 30300 WM number series 30050 30100 30200 30350 30500 30700 30750 30600 30800 30850 31000 Dimensions in mm B 82 70 136 156 70 90 119 239 119 239 119 199 70 120 70 120 70 90 43 82 94 94 94 94 94 94 94 94 94 72 T 69 69 69 69 100 100 100 112 112 112 100 o a o country specific threads Weight in grams 530 530 640 530 730 730 730 710 710 750 BSB e pressure 200 45 e e
40. all therapy devices except SOMNOtron O valve Technical Data see chapter TD6 WEINM ANN medical Mtechnology Home Mechanical Ventilation Home Mechanical Ventilation Our goal is clear significant improvement in quality of life Successful home mechanical ventilation sees to it that respiratory muscles recover and that the patient becomes more physically active As a result of greater mobility the patient improves quality of life and life expectancy Among the most frequently occurring illnesses which permanently overtax respiratory muscles are chronic obstruc tive lung and respiratory tract disorders nerve and muscle disorders scoliosis and chest thoracic wall disorders Home mechanical ventilation unloads the respiratory musculature with the help of ventilators and nasal or full face masks non invasive After a phase of acclimation to the device and accessories the patient can receive ventilation at home without a doctor s full time supervision Weinmann develops customized technologies for home mechanical ventilation which automatically adjust to the current situation to give the patient maximum support and at the same time relieve doctors and nursing staff Certified Quality O Management System meeting EC directive 93 42 EEC Annex II EN ISO 9001 2000 EN SO 13485 WEINM ANN medical technology Home Mechanical Ventilation VENTI ogic with JOYCE Full Face Operations panel with displ
41. and to clean and may even be put into the dishwasher SOMNO click 300 The heated humidifier is simply clicked into place without hoses or electrical plug on the front of the therapy device m Fits the therapy devices SOMNOcomfort SOMNOsoft SOMNOsmart 2 SOMNOvent S ST SOMNOset and SOMNOvent CR SOMNOaqua Specially developed for integration into SOMNOcomfort 2 e and SOMNObalance e The entire SOMNO aqua can be easily inserted into the device housing It s also easy to use and easy to clean Even when full the humidifier itself is non tilting up 4 b to 45 A small window lets the user check the level of water CLICK 2 in the tank CLICK 2 Attaches to therapy device CPAP20e with a simple click holds 280 ml of water six level setting on therapy device easy to clean j ys gt di A E 4 Bacteria filter a Bacteria filters keep the therapy devices hygienically pure for Qa up to 24 hours According to model bacteria filters are either y L Ss a reusable if the interior particle filter is replaced or disposable e f pr E 4 after a single use fo S Bacteria filter Ed Bacteria filter disposable reusable O Valve Via the O valve oxygen can be supplied to the patient from a central gas system a concentrator a liquid oxygen bottle or a gas cylinder In the event of a device failure the oxygen valve immediately cuts off oxygen delivery for safety reasons The oxygen valve can be used with
42. aneously By eliminating the need to switch back and forth between the PSG view and the ventilation monitor the Analogbox makes it easier for the doctor to operate the system and to make his diagnosis pressure flow leakage and tidal volume Four additional channels can be configured as desired Connection to all conventional PSG systems Compatible with Weinmann home ventilation devices VENTl ogic VENTImotion and BiLevel ST 22 Display of ventilation parameters from BiLevel ST 22 in SOMNOlab with the help of the Analogbox D A Venti 0 More oxygen For patients who need additional oxygen the O valve VENTI O can be adapted to the device with just a click It has an increased inlet pressure of up to 7 bar for use in the hospital and at home VENTI O Basic requirements for medical devices are defined in standards According to VDE association of electro technology elec tronics and information technology failure to fulfill the standards can suffice as proof of improperly executed work and may endanger the safety of the patient The DIN EN ISO 10651 norm which covers lung ventilators for medical use says If an oxidant is introduced into the flow of a ventilation system the manufacturer or operator must ensure that no rebreathing of the oxygen into the device Is possible should the oxygen concentration exceed 24 The idea is to prevent the build up of oxygen which poses the danger of fire
43. anufacturer as needed EN 55011 EN 61000 4 Parts 2 to 6 Part 11 about 26 dB A at 10 hPa 600 1100 hPa automatic altitude adjustment allows operation up to about 4000 meters operation standby O11 A 0 02 A 0 22 A 0 03 A SA 0 6 A at 10hPa Ap 0 3 hPa 4 20 hPa precision 0 4 hPa automatic 8 1 min CR AZMV with auto EEEPAP yes 6 5 hPa 160 l min at 6 hPa Ap 0 3 hPa at 12 hPa Ap 0 4 hPa at 12 hPa Ap 0 4 hPa lt 95 rel humid no condensation IPAP 4 20 hPa EPAP 4 18 hPa precision 0 4 hPa 4 18 hPa precision 0 4 hPa from 5 to 45 minute CPAP BiLevel S BiLevel ST BiLevel T in CPAP and Bi Level mode adjustable in 3 levels adjustable in 3 levels adjustable in 5 levels separate for inspiration and expiration 12 hPa 165 l min up to 1 um gt 99 5 up to 0 3 um gt 85 gt 250 hours with normal room air background frequency 6 minute CPAP B Level S Only for connection to SOMNOadjust WM 23930 and SOMNOsupport WM 23975 by authorized personnel or for control of O valve WM 24042 power consumption SOMNOadjust max 163 mA with SOMNOsmart 2 feed to PSG Two of following analog signals can be selected Pressure Flow Leakage lt 30 hPa Two of following signals can be selected therapy pressure O to 1 VDC O to 20 hPa flow O to 1 VDC 250 to 250 l min Oscillatory Pressure Signal OPS 0 to 1 VDC 0 to 100 loss of flow 0 to 1 VDC O
44. ar for all mask types and sizes made by Weinmann The circular opening holds the headgear firmly in place on the back of the patient s head and thus makes annoying slippage a thing of the past The crosswise strap construc tion provides even more holding power HEADstrap is made of a breathable skin friendly material and is delivered with either headgear clips for JOYCE and JOYCE Full Face or EasyClip Effective immediately HEADstrap will be provided with all our mask sets It can also be ordered separately Now only one headgear is required for all masks All this means that we now have masks that fit nearly every face and headgear that fits all patients 1 WM 26360 for JOYCE and JOYCE Full Face 2 WM 26365 for SOMNOmask und SOMNOplus Exhalation System Accessories Silentflow 2 The air flows quietly through the outlet gap and along the hose Noise suppressor The air quietly bubbles out through micropores Technical Data see chapter TD12 WEINM ANN medical technology Technical Data ZY Sleep Diagnosis SOMNOcheck effort SOMNO check 2 SOMNOcheck 2 R amp K SOMNO ab SOMNO ab Headbox and Transferbox SOMNO manager SOMNOlab PC Software MULTIBASE 2 OXYCOUNT mini CAPNOCOUNT mini smartOX E Sleep Therapy SOMNO comfort 2 CPAP20e SOMNOsoft SOMNO balance SONINO SMIFEZ aa cn dado adrede SOMNO vent CR SOMNOvent S SOMNO vent ST SOMNOSe cc cceceec
45. arameter statistics weekly compliance mandatory respiratory phases pastos ies alee el ee misai table Technical Data see chapter TD7 WEINM ANN medical Mtechnology Home Mechanical Ventilation BiLevel ST 22 The most comfortable BiLevel ST therapy between sleep lab and respiratory ward BiLevel ST 22 efficiently comfortably and economically com bines ventilation therapy for sleep related respiratory disorders and respiratory insufficiency For cases of mixed apnea Cheyne Stokes respiration adipose hypoventilation syndrome or mild COPD a specially designed range of ventilation modes and parameters plus the connection to polysomnograph systems make titration with BiLevel ST 22 very easy The overview of ventilation statistics and patient compliance data in the large display along with the device s simple operation help to increase patient acceptance and to reduce Comfortable therapy Therapy modes CPAP S ST and T Softstart function in all modes Separate settings for inspiration and expiration triggers Expiration trigger in ST mode can be turned off corresponds to aPCV Optimum titration and therapy monitoring Display of ventilation statistics and patient compliance on the device itself Display of changes between spontaneous and mandatory respiratory phases Transfer of up to eight ventilation signals into conventional the work of clinic personnel polysomnograph systems via the Weinmann Analogbox
46. at 1 5 bar 12 l min delivery of 0 Charge voltage 12 to 13 8 V Ambient temperature Motor output 50 W operation 5 C to 40 C 0 C to 50 C Max power consumption 35A storage 20 C to 70 C 40 C to 63 C Battery type lead 3 4 Ah Classification as per EN 60601 1 Electromagnetic compatibility degree of protection from electric shock type B water resistance IPX 1 radio interference suppression EN 55011 radio interference resistance EN 61000 4 2 bis 6 not relevant not relevant Battery service life Operation period after 14 hour 400 charge and discharge cycles within about three years 30 mins at highest suction level Alarms visual and acoustic at lack of oxygen supply discon E charge nection or low power reserves Suction capacity at 12 V and gt 20 l min Use with liquid oxygen systems yes outlet pressure 1 5 0 15 bar and at least 6 ae free flow Power supply l min delivery of O Max vacuum at 12 V Collection canister 0 8 bar 80 kPa disposable or reusable collection Battery pack 3 6 V NiMH battery pack WM 7295 canister Batteries 3 x 1 5 V type LR6 alkali manganese batteries or AA Overflow valve filter min 99 8 for particles of Charger 2 8 um Dimensions W x H x D 63 x 96 x 48 5 86 mm l Weight about 500 9 Volume of collection canister 900 ml Power supply 230 V 50 Hz 70 mA E Overflow protection overflow valve filter Temperature ran
47. ata Remote setting with SOMNOagjust or SOMNOsupport Analog signals for PSG feed pressure flow leakage OPP relative respiratory minute volume Mobile Small and light m Worldwide use with 100 to 240 V power connection Battery operation cars 12 V or trucks 24V with optional DC adapter also with simultaneous operation of humidifier Convenient and user friendly Suitable for full face masks m Mask test to check mask airtightness after device Is switched on Softstart and infinitely adjustable increased starting pressure m Click adapter for standard hose 2 level filter system with fine and coarse dust filters m Trolley suitable bag included in supply schedule The optionally integrated humidifier SOMNOagua can be in serted simply into the device housing Its high performance convenient operation and very simple cleaning make it a valuable addition to the device Some patients with obstructive sleep apnea have greatly varied pressure needs They are treated with auto CPAP devices that can always tell if a narrowing of the airways obstruction is taking place If that s the case the device reacts to prevent the airways from closing Auto CPAP devices by Weinmann are designed for needs oriented pressure adjustments and developed with tech nologies such as OPP or OPS for reliable recognition of central and obstructive events By combining information from several signals the device offers outstanding accura
48. ay and convenient menu selection with navigation button TA Mode VENTI ogic The first intelligent home mechanical ventilation device that automatically adjusts to the patient s breathing pattern VENTI ogic is the first intelligent home mechanical ventila tion device with adaptive controlled ventilation that always adjusts to the patient s breathing pattern and thus increases patient compliance VENTI ogic takes over breathing pattern analysis and ventilation setting within the range allowed by the physician Consequently patient adaptive home mechani cal ventilation represents significant time and expense savings for clinic personnel For patients with chronically weak respira tory mus cles the device provides greater independence and better quality of life Synchronized respiration adjusted to breathing pattern Automatic adaptation of ventilation pattern to the patient s analyzed respiratory pattern m Optimum synchronization provides obvious relief during titration in TA Timed Adaptive mode Time and money savings through automatic ventilation adjustment to changes in patient s breathing Optimum therapy monitoring m Effectiveness documented by TA statistics Clear graphic images of patient and device respiratory patterns Long term monitoring made possible by VENTIsupport software Broad therapy spectrum BiLevel modes TA new S ST T SX SXX CPAP Volume compensation Innovative operation m C
49. bers cost carriers and service providers Diagnosis concepts We offer sleep specialists our com prehensive know how involving sleep lab operations consulting software for administration data monito ring diagnostic hardware and concepts for complete system solutions Finances We create financing models for single leased devices up to complete laboratory facilities Coordination Through active and frequent contact with doctors and the combination of varied medical specialties we have created a competency network that benefits the patient in the form of high quality Care The homecare provider assumes responsibility for local patient services Dealers have high quality products and services and the necessary Weinmann certified know how for looking after patients WEINM medical technology ES Homecare System Solutions Clinical studies prove benefits Added to all that is our intense involvement in clinical research represented by our Science Research area Its main task is to manage clinical studies that test selected medical technological solutions to determine their benefit for patients and users These studies have to be of high quality Innovations prompted by clinical research can be successfully implemented only if a high degree of evidence and recommendation can be proven That s why national and international trade fairs and seminars and exchanges with experts are so important for us
50. bpm 1 three thermistors as total signal no measurement func tion at ambient temperatures between 33 C and 38 C integrated microphone logarithmic mean of inspiratory snoring noise 8 bit inspiratory expiratory pressure fluctuation 8 bit difference from ambient air pressure bandpass filter 30 250 Hz logarithmic mean of acoustic pressure signal micro phone or pressure fluctuation pressure sensor 8 bit mask pressure measurement with pressure measurement hose piezoelectric crystal sensor 8 bit piezoelectric measurement piezoelectric measurement SOMNO ab Headbox electro physiological signals ECG EEG EMG EOG Channal ECG EEG EMG EOG Dynamic range 500 250 mV 500V 250 LV 500 LV physical range 5mV V uV 500 pV 12 bit 12 bit 12 bit 12 bit Resolution 12 bit 12 bit 12 bit 12 bit Lower frequency limit 0 16 Hz 0 53 Hz 3 1 Hz 0 53 Hz 0 16 Hz 0 5Hz 2 7 Hz 0 5 Hz o Upper frequency limit 90Hz 70Hz 500Hz 70Hz 100 Hz 100Hz 500Hz 100 Hz aE ei _ about about about about Amplification ap prox 400 4000 8000 4000 3 3 3 3 2 available configurable electro physiological ports EMG EOG EEG ECG Can be set like EMG EOG EEG ECG about 40 MQ Specification Electrodes EMG EOG EEG ECG like EMG EOG EEG ECG Protected plug connection complies with DIN 42802 1 5 mm Technical Data Sleep Diagnosis SOMNOl ab Transferbox SOMNO lab PC Software Three available analog p
51. cer Technical Data see chapter TD11 Oxygen Medicine DB OXYTRON 3 basic device OXYTRON 3 complete system CYPRESS basic device No expenses for disposable or rechargeable batteries Available with different cylinder sizes 2 0 liter 0 8 liter 2 0 liter lightweight aluminum cylinder and transport systems 3 in 1 transport bag caddy WEINMANN medical Mtechnology D4 Oxygen Medicine E do OXYFLOW Basic OXYFLOW Il Versatile oxygen standing systems OXYFLOW Basic and OXYFLOW Revi offer a broad therapy E and utilization spectrum ranging from oxygen inhalation to secretion suction and ventilation Both are avallable with different oxygen operating panels J a OXYFLOW Basic A o Infinitely variable oxygen inhalation with humidification o wy requires the following equipment a 10 liter oxygen cylinder with cylinder jacket and PONY safe transport trolley an OXYWAY Fine pressure reducer and a humidifier OXYFLOW Revi In addition to the equipment delivered with OXYFLOW Basic this device also comes with a set of inhalation masks and a breath ing bag to increase oxygen concentration the proven OXYFLOW Revi with OMNIVAC COMBIBAG OMNIVAC secretion suction device and the COMBIBAG and oxygen administrator resuscitator OXYBAG Dependable emergency reserve The portable OXYBAG oxygen treatment devices are the ideal oxygen reserves for patients at home or on the road They can also be used for emergencie
52. ciety for Cardiology Cardiac and Circulatory Research DGK The DGK reports that 2 to 5 of people more than 75 years of age are af fected and up to 10 of those 80 years and older Triggers of heart failure include coronary heart disease cardiac muscle ailments and complications from high blood pressure The connection between heart failure and sleep related breathing disorders has also gained the attention of researchers The vital sup ply of oxygen to the body is interrupted by obstructive and central sleep apnea Cheyne Stokes respiration see box on page B8 The resumption of breathing is frequently caused by a waking reaction arousal in the brain In turn this triggers a long lasting stimulation of the sympathetic nervous system That means that the heart tries to beat faster and stronger blood pressure rises while the blood vessels except for the coronary arteries simultaneously constrict stress hormones are released and the body is put into a fight or flight mode All of this activity is an enormous load for an already weakened heart If they remain untreated sleep apnea patients have a very grim prognosis and a clearly increased risk of suffering a cardiac infarction or stroke Technical Data see chapter TD5 WEINM ANN medical M technology CR mode three pressure levels The needs of the patient Depending on the recognized events the three pressure levels IPAP upper pressure level during inspiration EPAP low er
53. cy in Its assessment of apnea hypopnea flow limitations and snoring WEINM ANN medical Mtechnology Technical Data see chapter TD4 SOMNOsmart 2 Auto CPAP therapy in combination with softPAP Auto CPAP therapy adapts to the patient and automatically adjusts the pressure to the needs of the sleeping patient according to respiratory events such as apnea and hypopnea flow limitations and snoring In SOMNOsmart 2 accurate event recognition is based on the unique combination of the OPS signal flow and snor ing signals The one of a kind algorithm guarantees effec tive therapeutic pressure that reliably and gently cares for the patient throughout the night Extremely quiet with high pressure constancy Comfortable with softstart and autostart Simple device operation Highly developed hygiene concept m Two level filter system with fine and coarse filters Adaptable humidifier SOMNOclick m Graphic analysis with PC software SOMNOsupport and SOMNOsmart 2 with JOYCE Full Face extensive diagnostic information for therapy monitoring RDI respiratory events snoring OPS leakages etc plus Suitable for use with full face masks in full face mode compliance data therapy calendar m Intelligent softPAP pressure relief for gentle care and com Remote setting with SOMNOadjust or SOMNOsupport fort can be combined with auto CPAP Starting pressure can be set at higher level especially for Analog signals for P
54. during the first part of the night and then treated at the recommended titration pressure CPAP therapy pressure for the rest of the night Pressure Use The auto titration mode automatically determines the re quired CPAP therapy pressure for patients with constant pressure requirements or recommends continuous APAP therapy when an analysis shows that a patient needs vari able pressures CPAP Mode SOMNOset functions like a CPAP therapy device e g Weinmann s SOMNOcomfort and provides continuous pressure to the patient at the pre set level Pressure Use The CPAP mode is used in CPAP therapy for patients who require constant pressure and for manual titration WEINM ANN medical Mtechnology Mode PRESSURE PROFILE Pressure adjustment does not depend on respiratory events but rather on a timed and pre defined pressure profile Pressure The therapeutic effect of the CPAP level can be analyzed with polygraphy or polysomnography or by means of re spiratory events stored in the device The doctor determines CPAP therapy pressure on the ba sis Of available data Pressure Time Use The mode Pressure Profile is used for automated man ual titration based on a time related pre defined pres sure profile This mode is also suitable for automatic CPAP therapy checks The therapeutic effect can be observed at changing pressure levels APAP Mode Auto CPAP SOMNOset reacts like We
55. e diagnostics F Y 000 Sleep Therapy gl Es TE de Home Mechanical Ventilation Oxygen Medicine Patient Interface They may suffer from fatigue exhaustion dyspnea depression and even circulatory disorders or stroke all of which can drastically affect the patients day to day lives Therefore it s essential that they receive effective treatment which offers the greatest possible comfort and convenience and thus guarantees better patient compliance At all times and almost everywhere around the world people are being cared for and effectively treated with products we make In cooperation with our partners we strive to achieve the best therapy results within a functioning network of patients treating physicians and cost carriers We do this by following a strategy that concentrates our strengths and know how on comprehensive therapeutic offerings and not just on individual devices The patient is at the core of our efforts for the simple reason that we consider security and quality of life inseparable We invite you to take a look at the following pages and see for yourself the range of products and services we ve designed and developed always keeping close to people and their needs technology WEINM medical EN Table of Contents System Provider Weinmann Partnerfor Cie coer acta nena eg le ace cams ae ren 6 Intro dQUIGhHONnS cette a eee emer eet A 1 SOMNOcheck 2 R amp K anar canaria
56. ececececeeeeeeeeees SOMNOclick 300 Bacteria filter O valve SOMNOaqua SOMNOsupport Converter box Converter Cabel ccccccccsccecsccecececcecececcucecavausecavanees Management System Q Certified Quality meeting EC directive 93 42 EEC Annex EN ISO 9001 2000 ENISO 13485 Home Mechanical Ventilation VENTI ogic VENTImotion Bilevel ST 22 wen A E TD 7 VENTIclick VENTI O VENTIpower AnialOG Ox ASR o TD8 Converter box Converter cabel VENTIpower Charger VENTIsupport TD9 DN Oxygen Medicine OXYMAT 3 easyOX OXYFLOW Basic OXYFLOW Revi OXYcontrol 2 OXYBAG Hit reie TD 10 OXYWAY Fix OXYWAY Fine OXYWAY Fast OXYWAY Click OXYTRON 3 CYPRESS ACCUVAC BASIC ers ae a ee ee eee Nene eee ee TD 11 E Patient Interface JOYCE JOYCE Full Face SOMNO plus SOMNO mask Silentflow 2 Noise Suppressor TD 12 WEINM NN medical technology Techn ical Data Sleep Diagnosis Technical Data Product class as per 93 42 EEC Dimensions WxHxD Weight Power supply Average power consumption Operating life of battery p Storage Data output Power Pack Charging Signals Messages LEDs Audio Position Sensor Position sensor Range Position precision SOMNOcheck effort lla 65 x 130 x 30 mm about 240 g with power pack NiMH power pack WM 94051 about 340 mW ack about 13 hours integrated data storage with data
57. echnology Scaling OV 1V O hPa 38 hPa 100 l min 315 l min O l min 315 l min Oml 3000 ml VENTI O lla 80 x 93 x 30 mm about 195 g operation 5 C to 35 C storage 40 C to 70 C 600 1100 hPa inlet only hoses with inner diameter of 4 mm outlet only hose system WM 23737 12 V DC 125 mA degree of protection from electric shock type B protection from electric shock protection class II EN 55011 EN 61000 4 2 to 3 EN 61000 4 8 lt 95 relative humidity no condensation lt 4 l min O 250 hPa 7000 hPa 4 to 35 hPa 1 hPa 1 cm H O VENTIpower 343 x 123 110 mm about 4 4 kg 20 NiMH cells Form D 6500 mAh gt 3 5 hrs at 35 W discharge voltage gt 500 charge cycles at typical DOD depth of discharge 50 operation 5 C to 35 C storage 15 C to 50 C optimum lt 20 C 700 1060 hPa degree of protection from electric shock type B protection from electric shock protection class II IP XO EN 55011 EN 61000 4 parts 2 6 11 lt 90 relative humidity no condensation 40 V DC 5 0 2000 mA pulsed current up to 3 A for max 500 ms 12 VDC 5 100 600 ma voltage stability over the com plete on load and input voltage range of any duration short circuit current max 200 of maximum nominal current output voltage of 40 V supply is independently monitored and switched off from 48 V 2 V max each 2200 uF Pin 1 2 40 V black brown Pin 3 4 GND red
58. en se arent Same pa or E 2 O JONCEGEL a A e E3 JOYCE Full Escort rt ar RN Sa ana cin E5 SOMINQ a e ed ea ES SOMNONISSK CA a E share su eet E5 Device Components and Accessories E6 SIGE DID IAGINOSIS aussi eeceee ns TD 2 Sleep TINS do Py fee O TD 4 Home Mechanical Ventilation cccococccnccccnnnnnnnos TD 7 Oxygen Medicine dci TD 10 Patient Interface saronno aana ai TD 12 WEINIM NN EN Homecare System Solutions System Provider Weinmann Partner Tor Life Successful treatment concepts implemented in intelligent solutions Among decisive factors for the success of treat ment are prod ucts finely tuned to each other logically designed processes and customization That s why it s so important for us to know exactly the needs of the customer the treating physician and the patient We rely on decades of experience in offering optimal therapeutic solutions with which we satisfy nearly all treatment require ments We have a comprehensive portfolio of high quality products for sleep diagnosis and therapy home mechanical ventilation and oxygen medicine each of which is perfectly coordinated with the others To our customers we offer the advantage of having complete responsibility for all system components in one hand Thanks to our modular system we deliver customized and complete solutions for individual patients and medi cally trained users such as the staff in sleep labs Our innovative solut
59. ensor integrated in device right side left side abdomen back standing about 45 15 0 40 hPa 1 hPa 50 100 70 lt SpO lt 100 better than 2 precision SpO lt 70 not validated 30 to 250 bpm 1 bpm to 2 of displayed value three thermistors as total signal no measurement func tion at ambient temperatures between 33 C and 38 C integrated microphone logarithmic mean of inspiratory snoring noise 8 bit inspiratory expiratory pressure fluctuation pressure sensor flow approximation through square root calculation 8 bit difference from ambient air pressure bandpass filter 32 220 Hz logarithmic mean of acoustic pressure signal micro phone or pressure fluctuation pressure sensor 8 bit 8 bit differential pressure measurement with pneumo T adapter piezoelectric crystal sensor integrated in housingt 8 bit sensor integrated in housing piezoelectric measurement SOMNO ab lla Bodybox 65 x 130 x 30 mm Headbox 66 x 107 x 31 mm Transferbox 95 x 155 x 47 mm about 500 g without PC depends on system see System Requirements via fiber optic cable or LAN execution and results of sensor and impedance tests sensor integrated in device right side left side abdomen back standing about 45 15 0 20 hPa 0 2 hPa 50 99 at SpO above 85 1 5 percentage points at SpO between 75 and 85 2 percentage pts at SpO between 50 and 75 3 percentage pts 30 to 250
60. erland G Weinmann AG Neuenhof T 41 0 56 4 16 41 11 E info ch weinmann de www weinmann de France Weinmann S A R L Paris lgny E T 33 0 1 69 35 53 20 Live and breathe System Solutions for Home E ae eee tee Mechanical Ventilation Sleep and Oxygen Medicine www weinmann de Asia Pacific Weinmann Asia Pacific Co Ltd Bangkok T 66 0 2 7 63 67 00 E info asia weinmann de www weinmann de Australia Weinmann Australia Pty Ltd Melbourne T 61 0 3 95 43 91 97 E infoBau weinmann de www weinmann de diagnostics New Zealand Weinmann New Zealand Ltd New Plymouth T 64 0 6 7 59 22 10 E info nz weinmann de Instantly under Control System Solutions for Se non invasive Diagnosis g China Weinmann GmbH Co KG Shanghai Rep Office T 86 21 32 26 26 89 E infoOcn weinmann de www weinmann de emergency homecare diagnostics WEINM NN medical technology O Copyright Weinmann Hamburg Duplication of any kind only with the express permission of Weinmann All rights to design and specification modifications reserved 3506 2 01 GB 1107 2
61. fort device which set the standard for CPAP therapy SOMNOcomfort 2e is small light extraordinari ly quiet and very simple to use even more so with the new integrated heated humidifier An unbeatable duo in top form for greater compliance The heated humidifier SOMNO aqua is ideal in many ways for patients who suffer from dried out nasal mucosa SOMNOagua can be inserted easily into the device housing and just as easily removed for cleaning Comfortable user friendly dependable Very quiet optimized to a pleasant mask sound m Pressure constancy for high quality CPAP therapy m New space saving device design Optional integrated heated humidifier Power supply from 100 to 240 V for worldwide use Optional DC adapter for mobile use can be connected to 12 Vor 24V m Patient friendly three key operation including a raised on off key Click adapter for standard hose Trouble free cleaning Read out of compliance data with PC software SOMNOsupport m Remote settings with SOMNOadjust m Supplied with trolley suitable bag User friendly m Simple proven three button operation Trouble free cleaning Quiet lt 30 db A Light only 1 25 kg Pressure constancy Use of standard tube Analysis of compliance data with PC software SOMNOsupport Date related compliance data with or without humidifier tor 365 days m Remote setting with SOMNOadjust or SOMNOsupport Functions Softstart function 5 to 30
62. ge operation O C to 40 C Suction hose 5 mm Classification as per EN 60601 1 Battery pack Operating time storage 40 C to 70 C degree of protection from electric shock type B about 50 hrs at stage 4 and 20 breaths per minute length of 1800 mm Wall bracket for ACCUVAC Basic and ACCUVAC Rescue Charging time lt 2 hrs for full charge Fulfilled product norms EN 1789 Dimensions 3 in 1 transport bag W x H x D Dimensions W x H xD 140 x 185 x 33 mm Dimensions W x H x D 200 x 750 x 170 mm Weight 270g Weight 1 hPa 1 mbar about 1160 g WEINM NN medical Mtechnology TD12 Technical Data Patient Interface Technical Data Product class as per 93 42 EEC Dimensions W x H x D Weight Therapy pressure range Hose connection Pressure measurement port Width of headgear clip Temperature range Flow resistance Anti asphyxia valve JOYCE Full Face at device breakdown Sound pressure level at 10 hPa Cut off pressure anti asphyxia valve JOYCE Full Face Usage life Materials Technical Data Product class as per 93 42 EEC Dimensions W x H x D Weight Therapy pressure range Hose connector Pressure measurement port Width of headgear Temperature range Flow resistance Usable life Materials Technical Data Product class as per 93 42 EEC Connection on the mask side of set up Connection on the hose side of set up Therapy p
63. gth Patients on long term ventilation can be released from the hospital earlier to enjoy freedom of movement in familiar surroundings at home Broad therapy spectrum Non invasive S ST T modes and CPAP Expanded respiratory time window X tended respiratory freedom M in new assisted SX and SXX modes m Volume compensation with targeted tidal volume High trigger variability separate for inspiration and expiration adjustable tor each patient plus expiration trigger in ST mode that can be deactivated Variable speeds for pressure rising and falling during inspira tory and expiratory phases with graphic representation Complete analysis a Statistical analysis of ventilation parameters with actual and mean values and analysis of compliance data in display Detailed analysis by VENTIsupport ventilation software Comfortable therapy VENTImotion with SOMNOmask and bacteria filter Whisper quiet volume at only 25 dB A Softstart also available in T and ST modes for easy first time set up for patients with initially high inspiration pressure VENTI motion Functional transport bag and rechargeable battery pack VENTloower for ventilation away trom home Innovative operation Can be switched on with the touch of a key E Intuitive user guidance via a scroll menu similar to a car s navigation system Direct access to the most important ventilation parameters m Remote setting via VENTIsupport software
64. h humidifier Simple device operation Highly developed hygiene concept Analysis of compliance data therapy calendar with m Two level filter system with fine and coarse filters PC software SOMNOsupport Adaptable heated humidifier SOMNOclick m Remote setting with SOMNOadjust or SOMNOsupport SOMNOvent ST BiLevel ST therapy In addition to treatment of sleep related respiratory disorders BiLevel ST therapy can be used by patients with general respiratory insufficiency such as chronic obstructive pulmonary diseases COPD respiratory mechanism scoliosis neuromuscular disorders and by patients with partial central respiratory control disorders Aids breathing simply safely and sensitively SOMNOvent ST offers all biLevel modes S T ST and thanks to its sensitive trigger gently adjusts to the breathing pattern of each patient SOMNOvent ST with O valve SOMNOclick 300 and JOYCE Extremely quiet due to unique noise suppression High degree of pressure constancy m Two level filter system with fine and coarse filters Comfortable with softstart and autostart Adaptable heated humidifier SOMNOclick Adjustable trigger m Analysis of compliance data therapy calendar with PC Background frequency for additional safety software SOMNOsupport Simple device operation m Remote setting with SOMNOadjust or SOMNOsupport Highly developed hygiene concept See also BiLevel ST 22 Page C6 Cheyne Stokes respiration C
65. heyne Stokes respiration is characterized by periods of gradually increasing and decreasing tidal volumes interrupted by periods when breathing ceases entirely apneas It is observed primarily in patients with severely weakened cardiac muscle congestive heart failure Because the heart is weak it is incapable of guaranteeing an adequate supply of blood and thus oxygen to the body Cheyne Stokes respiration generally occurs during sleep Patients affected by this ailment suffer from shortness of breath after even slight physical effort Their prognosis is not good Devices specially designed to treat Cheyne Stokes respiration are available They counteract the periodic increases and decreases in the patient s respiration and make sure that regular breathing is eventually restored Patients benefit from this treatment which allows cardiac edema to decrease over time reduces the incidence of dyspnea and nearly eliminates the need for nighttime trips to the toilet WEINM ANN medical Mtechnology Technical Data see chapter TD5 Titration The titration device SOMNOset gives doctors reliable and accurate assistance in determining the required CPAP therapy pressure Based on the SOMNOsmart 2 technology SOMNOset precisely processes all respiratory events Flow and snore signals along with OPS are analyzed and stored as events such as obstructive or cental apnea SOMNOset Automatically the best titration The new automatic CPAP titra
66. homecare Live and breathe System Solutions for Home Mechanical Ventilation Sleep and Oxygen Medicine Product Catalog 11 07 WEINM ANN medical Mtechnology y iW Al N Mil pa 7 i i L 1 E III Effective and flexible Patient Care at the Center of our Efforts Solutions for the patient mean so much more than diagnosis and the initiation of standard therapy Every single patient needs a specially tailored examination method capable of obtaining medical information relevant to his case This calls for a broad therapy spectrum that can satisfy all patient requirements As a specialist in this area of medical technology for several decades Weinmann has acquired extensive knowledge and has made a name for itself on the international market with its high quality products When we refer to products we don t mean individual devices or this piece of software or that We see ourselves more as a provider of treatment offerings complete systems and service packages Each solution contains highly effective and innovative care concepts that flexibly respond to individual customer requirements Whether it s sleep apnea chronic bronchitis or respiratory insufficiency more and more people are suffering from serious respiratory disorders Each of these diseases significantly reduces the quality of life of the persons affected emergency homecar
67. ing The Website also offers current job openings press releases and a list of inter national Weinmann sales partners and lots more emergency homecare diagnostics WEINM NN medical technology Everything under one big roof Our Center for Production Logistics Service Our Center for Production Logistics Service has been in operation in Henstedt Ulzburg near Hamburg since 2006 Short ways quick proc essing and competent service personnel with capacity to spare make this center different from the rest Here Weinmann can centrally and efficiently coordinate its product maintenance and repairs plus stockkeeping and world wide shipping SS A AAA II E ll Weinmanns Center for Production Logistics Service your address for Delivery Pick up Sending in devices for maintenance and repair Center for Production Logistics Service Weinmann Ger te f r Medizin GmbH Co KG Siebenst cken 14 m D 24558 Henstedt Ulzburg T 49 0 4193 88 91 0 m F 49 0 4193 88 91 450 emergency homecare diagnostics WEINM NN medical Mtechnology Sleep Diagnosis SN D Sleep Diagnosis Measure determine know tracking down the disease Daytime sleepiness decreased performance and circulation problems can be the result of disrupted sleep There fore people thus affected who may also have trouble falling or staying asleep should have a sleep check up With the help of a sleep diagn
68. inmann s auto CPAP therapy device SOMNOsmart 2 and immediately adjusts the pres sure in response to each therapy relevant event Pressure Use The APAP mode provides continuous auto CPAP therapy tor patients with variable pressure requirements e g de pending on body position or sleep stage or night to night variations Technical Data see chapter TD5 Software Sleep Therapy B11 SOMNOsupport Setting and analysis software for Weinmann devices SOMNOsupport is the supplemental PC software for all Weinmann therapy devices and is available to doctors sleep labs and specialized dealers This software permits the reading and graphic representation of compliance data therapy calendar and the PC managed remote control setting of all therapy devices and the detailed analysis of therapy data per device SOMNOsupport also offers the following functions Transmission of stored data to PC via converter box from version 3 15 also with USB connection via converter cable m Visualization of all therapy relevant parameters m Remote setting of therapy devices m Graphic representation and analysis of therapy course and patient compliance Detailed diagram of signals and events during titration night m Documentation and archiving of therapy success m Print out of therapy reports Decision support for the selection of therapy device and determination of CPAP pressure Remote setting of relevant
69. ions in titration diagnosis and therapy are implemented in individual and economical systems with long lifecycles and are supported by reliable service for installation maintenance and updates through our network of certified dealers WEINM ANN medicalMtechnology Homecare System Solutions 7 System Provider Components we offer Therapy solutions Finances F Homecare provider Coordination j Marketing o i Patient Diagnosis Economical concepts 4 Doctors and patients are at the center of attention Today we offer them a range of services which include Our therapy solutions They range from varied forms of CPAP therapy and oxygen treatment to therapy concepts for home care ventilation Each patient gets the treatment he needs plus the appropriate device and all the necessary accessories We place a great deal of value on the high quality connection of man and machine which we refer to as Patient Interface Our nasal and full face masks fall into this category Our marketing Through two way communication with target groups we make sure that our diagnostic and the rapeutic solutions are understandable that everyone is heard and that a dialogue with our customers and patients physicians and health insurance companies has a chance to develop Economy By achieving a high diagnostic hit rate and good therapy compliance we look after profit ability in terms of prescri
70. is part of the equipment Recommended use of SOMNOset modes ESOO Taim Titration Therapy Setting Mode Method of Therapy Process Result Pressure recommendation Automatic titration CPAP target pressure optional with Split Night APAP with variable pressure course Pressure adjustment Autotitration based on indexing CPAP Summation of events Pressure Fixed time defined i A a A N Profile pressure levels ee nea ey Sie APAP for changing CPAP therapy monitoring pressure needs Pressure adjustment over APAP required APAP single events close to APAP m APAP therapy CPAP for constant pressure needs pressure needs Manual titration CPAP Constant pressure CPAP E CPAP target pressure CPAP therapy monitoring Technical Data see chapter TD5 WEINM ANN medical technology B10 Sleep Therapy SOMNOset Four modes one goal The best therapy decision AUTO TITRATION Mode Pressure is adjusted on the basis of ongoing index forma tion according to an event s frequency and severity At the end of a titration night SOMNOset determines the recom mended titration pressure The pressure curve shows the patient s suitability for CPAP or APAP therapy Pressure The recommended titration pressure is read out with the help of SOMNOsupport or displayed on the device at the touch of a button SET key When the option Split Night is chosen the patient is titrated
71. lapp Stefanie 6 7 1996 PID Last name Weinmann Soft Stefanie 6 77 1996 PIO ooo u NR i i i First name Gottlieb Weinmann Gottlieb 10 12 1923 PID O BE Street Documents Recordings Refresh Listing Hie pea 0 22 2006 SC PG Nasenbrille Patient data administration Technical Data see chapter TD3 WEINM ANN medical M technology AB Sleep Diagnosis Accessories Once the processing of the data captured by SOMNO ab has been completed a click of the right hand mouse key will flag each recording released for archiving A A O PR ERA ae eee When SOMNOarchiv the archiving tool installed with SOMNOmanager lite is started all the flagged files are listed and made available for archiving on a CD or DVD SOMNOarchiv creates a directory for each CD DVD and stores the name of the CD DVD with each recording in the database so that the raw data can be retrieved if necessary A table of contents can be printed immediately If the recording is required at a later date SOMNO manager will request that the appropriate CD DVD be placed in the drive SOMNOarchiv OXYCOUNT mini with Multibase Pulse oximeter OXYCOUNT mini measures oxygen saturation and pulse a quickly and precisely independent of external power supply OXYCOUNT mini with Multibase 2 OXYCOUNT mini CAPNOCOUNT mini Capnometer CAPNOCOUNT mini measures the CO content in the patient s exhaled breath CAPNOCOUNT mini
72. lity O Management System meeting EC directive 93 42 EEC Annex II EN ISO 9001 2000 EN SO 13485 WEINM ANN medical Mtechnology WEINM JOYCE Full Face NV JOYCE Full Face JOYCE Full Face JOYCE Full Face JOYCE Full Face 40 hPa JOYCE Full Face NV 40 hPa Weinmann s full face mask Anatomical fit convenient handling and a clever concept are all combined in JOYCE Full Face the mask for sleep apnea and home mechanical ventilation patients Compared to other full face masks the small and light JOYCE Full Face guarantees greater wearing comfort lts modular design principle is also suitable for our nasal mask JOYCE That helps to optimize inventory management Fitting the mask to the patient is especially easy and practical with JOYCE Full Face Simply remove the elbow piece and look into the mask to check the fit JOYCE NV JOYCE JOYCE JOYCE JOYCE 40 hPa JOYCE NV JOYCE NV 40 hPa Nasal masks JOYCE can be assembled specially for each sleep apnea or home mechanical ventilation patient JOYCE is available in four mask models in four sizes each with two mask seals of different strengths All these standard masks are available as vented and non vented variations NN medical Mtechnology Perfect fit Proven ball and socket joint m Anatomical fit for greater wearing comfort m Easy to fit to patient a Very quiet Lightweight m Convenient handling e g easily attached to mask seal
73. m operation 5 C to 40 C storage 20 C to 70 C vented at 50 l m 0 02 hPa at 100 l m 0 11 hPa non vented at 50 l m 0 09 hPa at 100 l m 0 37 hPa 28 dB A 6 to 12 months depending on frequency of use and cleaning mask seal silicone LSR forehead cushion TPE PP mask body polycarbonate PC forehead support polypropylene PP seal for ports silicone LSR rotating sleeve polypropylene PP safety ring TPE PP elbow polycarbonate PC headgear clip POM HEADstrap polyester lycra polyurethane nylon spandex All parts of the nasal mask are latex free SOMNOmask blue Technical Data SOMNOplus lla 80 x 140 x 90 mm about 55 g 4 30 hPa Cone as per DIN EN ISO 5356 1 Y 22 mm 4mm max 28 mm operation 5 C to 40 C storage 20 C to 70 C at 50 l min 0 06 hPa at 100 l min 0 22 hPa 29 dB A 6 to 12 months depending on frequency of use and cleaning mask seal silicone LSR mask body polycarbonate PC elbow polycarbonate PC rotating sleeve polycarbonate PC seal for ports silicone LSR forehead cushion silicone LSR supprt polypropylene PP HEADstrap polyester lycra polyurethane nylon spandex All parts of the nasal mask are latex free Noise Suppressor Product class as per 93 42 EEC lla Connecting piece cone in conformance with DIN EN ISO 5356 1 Y 22 mm 4mm max 28 mm operation 5 C to 40 C storage 20 C to
74. m Remote control via SOMNOadqjust or VENTIsupport software a Hr 0 u by D ai a r Safety for all patients m Alarms for disconnection power loss and device error m Filter system with high filtration efficiency 99 7 and longer lifetime 1000 hrs m Bacteria filter system for change of patient in titration use Self explanatory operation m Multi lingual scroll through menus in the VENTI product line and selection knob for the most significant parameters BiLevel ST 22 m Convenient setting options in offline or online operation with fan switched on Large display of all parameters and patient data Display of mean values in statistics menu Offline operation in BiLevel ST 22 with JOYCE Full Face and VENTIc ick doctor s menu BiLevel Bilevel ventilators provide a splinting of the patient s upper airways for treatment of obstructive sleep apnea Further more they care for the patient with the necessary tidal volume and offer back up ventilation when spontaneous breath ing is interrupted by central apnea The difference between device versions while the BiLevel S device is con trolled by the patient so called triggered ventilator the Bilevel ST device is machine controlled With a Bilevel S S spontane ous device such as SOMNOvent S breathing support is initiated and terminated by the patient s spontaneous breath ing Compared to CPAP ventilation this type of sup
75. mobile polysom nography in accordance with Rechtschaffen and Kales In sta tionary use the data are transmitted to the control room by USB or Bluetooth or optionally via a local network In mobile use they can be stored on the integrated interchangeable CompactFlash CF card All data for a complete polysom nography including video are visualized and analyzed with SOMNO ab software which also supports sleep stage analysis with ARTISANA Benefits for you a Channel combination according to internationally recognized standards for polysomnography Online use in sleep lab and clinic USB or wireless Compact simple application on patient SOMNO ab software integrated video and audio signals TCP IP for attended polysomnography a Maximum integration differential pressure sensor all amplifiers pulse oximetry position sensor Bluetooth module etc are contained in basic device SOMNO check 2 Superior sleep diagnosis that s mobile safe and simple Easy to operate and convenient to use SOMNO check 2 Is a mobile polygraph combining sleep apnea and PLMS screening functions in a single device Interchangeable application graphics make sure that the electrodes are correctly connected to the device WEINMANN Back of SOMNOcheck 2 WEINMANN medical Mtechnology Ee A NN SOMNOcheck 2 R amp K with trunk cable Mobile use up to 20 hours several recordings possible with rechargeable battery and in
76. n W 0 01 0 1 10 100 VENTI ogic VENTImotion BiLevel ST 22 lla 23 x 12 5 x 34 230 x 120 x 280 mm about 4 5 kg about 3 7 kg operation 5 C to 35 C storage 40 C to 70 C 750 1100 hPa 115 230 V AC 50 60 Hz tolerance 20 10 600 1100 hPa operation standby operation standby 0 2 A 0 043 A 0 15 A 0 043 A 0 4 A 0 068 A 0 3 A 0 068 A protection from electric shock protection class Il degree of protection from electric shock type B EN 55011EN 61000 3 2 EN 61000 3 3 EN 61000 4 2 to 6 EN 61000 4 8 EN 61000 4 11 about 35 dB A at 20 35 hPa about 31 dB A at 20 hPa about 32 dB A at 20 hPa about 29 dB A at 15 hPa about 30 dB A at 15 hPa about 27 dB A at 12 hPa about 28 dB A at 12 hPa about 25 dB A at 10 hPa about 26 dB A at 10 hPa about 23 dB A at 7 hPa about 24 dB A at 7 hPa about 62 dB A 6 35 hPa 6 to 22 hPa 4 20 hPa 4 to 20 hPa 4 20 hPa 4 to 20 hPa 0 6 hPa 0 6 hPa 0 2 hPa 1 hPa 1 cm H O 0 2 hPa 1 hPa 1 mbar 1 cm H O gt 0 hPa lt 60 hPa 6 to 45 l min 0 5 l min 1 l min inspiration time 20 to 67 of respiratory period increment 1 precision 1 adjustable in in 6 stages separate for inspiration and expiration in ST mode expiration trigger can be deactivated adjustable in 6 stages adjustable in 6 stages at 23 C 15 300 l min 15 l min 270 l min 15 l min Pa at 20 hPa Ap lt at 14 hPa Ap lt 1 hPa at 10 hPa Ap lt 1 hPa at 7 hPa
77. nalyses like those performed by Weinmann s unique ARTISANA soft ware accelerate the work of examining the recorded signals The Report Generator lets the user compile the measurement results quickly and simply into easy to read reports Just a few mouse clicks show the logical and user friendly way to the results Recordings are made of the standard parameters for routine sleep examination as defined by the German Sleep So ciety DGSM Visualization You decide what the configuration should look like with your choice of channel sequence color filter and scale and then you save it all under My visualization On the monitor you can look at two selected channel groups simultaneously and synchronized with the video image at dif ferent resolutions from one second up to an entire night Ss eis t OEBC k Fha Wa a A ee LF o da A w MP E Excerpt visualization in two scales of your choice Online therapy settings of Weinmann devices Configure the patient device directly on the monitor with SOMNOagjust Analysis Whether you re doing cardio respiratory analysis or sleep stage PLMs arousal or snoring analyses the quality of the analysis and the simple representation of the results have been validated by clinical trials Video You can see the video image synchronized with the record ing During the analysis one frame per epoch will be dis played You can start the video
78. nology Es Sleep Therapy SOMNO balance e Auto CPAP therapy sleep at last The new auto CPAP therapy device offers balanced treatment of obstructive sleep apnea Dependable distinction is made between obstructive and central apnea by the new OPP Ob structive Pressure Peak technology SOMNObalance e is small light and extremely quiet The therapy device makes operation very easy and cleaning procedures of the integrated humidi tier SOMNO aqua too absolutely trouble free SOMNObalance e is available with the integrated heated humidifier SOMNO aqua accessory Obstructive Apnea Central Apnea Flow OPP Thorax Abdomen Pressure _ OPP Obstructive Pressure Peak to distinguish central from obstructive apnea Auto CPAP Balanced therapy Quiet with stable pressure CPAP and APAP modes with pressure relief option softPAP OPP Obstructive Pressure Peak technology to distinguish central from obstructive apnea Epoch based need oriented pressure adjustment Informative m Patient oriented info menu in display makes therapy success visible with information about RDI Respiratory Disturbance Index leakage and 90th percentile Extensive statistical data for therapy monitoring including CPAP with analysis by PC software SOMNOsupport m 35 hours of high resolution titration data and signals m 180 days of compliance data with compressed signals m 365 days of annual compliance d
79. nology Our wide range of oferings includ SNe DAET ae fi a ples A TUTE POCE Ce FOU d UC emergency an 3 Anos Dur itemei fie al i Jur Center for Production Logistics wrvico Your address for delivery pick up ind device shipping Growing room DE downloads image brochure atalogues omergoncy homecare for ideas and innovations agnostics Login Germany Land of Ideas SHG0Ge Selected landmark 2007 emergency nomecare A i Home More Heme Home Ventilation and Monitoring Sleep Diagnosis Pulse Oxymetry About Us Delibrifation Heep Therapy Capnometry Purdhasing Orygen Systems for Emergency Veb cios Home Mechanical Ventilation DEM Partnersivp Careers Jobs Stand alone Monitoring Oxygen Therapy Information Portal Soence Research Transport Containers Patent Interface Contact Wesmann Academy Suchon information Portal E Trade Faas and Exhebitions Ousaster Medicine Contact Press Confor information Portal Information Portal Go online Versatile and always available Do you need information about the products Weinmann offers Are you looking for an updated user manual in your language the newest product catalog or scientific background material At weinmann de you ll see all the information you need on several clearly laid out and easy to find pages at any time of day or night More than 1200 PDFs and numerous high resolution product photos are available for download
80. ntilation patient is now available as a nasal or full face mask in a gel model Unmatched wearing comfort distin guishes the newest generation of individually assembled masks m The only gel mask with ball and socket joint For a very good fit m Pleasantly soft feel very light m Mask seal AND forehead cushion of gel Coated with skin friendly silicone only the filling is made of gel Particularly hygienic thanks to single layer mask seal JOYCE GEL Familiar JOYCE modular system JOYCE GEL NV JOYCE Full Face GEL JOYCE Full Face GEL NV Compliance Compliance is the term used to describe the extent to which the patient is willing to follow the doctor s instructions for long term treatment It covers the patient s observance of the doctor s orders to take medication and to use the prescribed therapy even when he doesn t always believe in the effectiveness of the therapy or finds it unpleasant or fails to see an immediate improvement Technical Data see chapter TD12 WEINMANN medical Mtechnology 4 7 j l i JOYCE Full Face The full face mask with the plus in extra chin stability Secure fit together with greater wearing comfort those are the features that distinguish JOYCE Full Face the tried and tested mask for every sleep apnea and home ventilation patient from the rest In this model JOYCE Full Face works with a two chamber principle The first chamber is f
81. odels are offered for use in pediatrics with a flow meter for children that allows precise settings from 0 2 to 3 liters per minute The low maintenance OXYMAT 3 weighs only 19 5 kilograms and comes with four rollers with brake and a carrying handle The filter can be changed without opening the device Weinmann gives a five year warranty on all functional parts of OXYMAT 3 devices with a serial number higher than 43 000 Performance features Oxygen flow of 1 to 5 liters per minute or 0 2 to 3 liters per minute as dosage monitor or flow meter model Best therapy quality with high oxygen concentration 95 1 3 Vol O at 1 to 4 liters minute m Whisper soft at only 40 dB A High level of patient safety ensured by the device s self test when it is switched on a visual and acoustic alarm system in accordance with DIN EN ISO 8359 and a bubble humidi fier that can be sterilized Economically beneficial low power consumption low number of parts and a five year warranty m Service is made easy by modular design with quick plug in connections simple filter change and adjustable rollers Performance features m Oxygen flow can be set from 1 to 5 liters minute flow meter integrated in housing Available in two models E as single flow meter model for home care E as double flow meter model for hospital use Therapy efficiency of 93 3 vol with an oxygen concentrator Quiet about 45 dB A m Continuous
82. onnecting piece polycarbonate PC porous filter polyethylene PE Contact us or get information about our newest deve lopments and plans on our Web site www weinmann de On our site you ll find our complete range of products and services all contact data and detailed background information Weinmann Ger te f r Medizin GmbH Co KG Corporate Communication Kronsaalsweg 40 D 22525 Hamburg Germany T 449 0 40 5 4702 0 F 49 0 40 5 47 02 461 E info weinmann de We reserve the right to make changes to future designs and catalogue misprints without notice Please refer to our current offerings Further information and technical details are available upon request WEINM ANN medical Mtechnology Germany Weinmann Ger te f r Medizin GmbH Co KG P O Box 540268 D 22502 Hamburg Kronsaalsweg 40 D 22525 Hamburg E infoQweinmann de www weinmann de T 49 0 40 5 47 02 0 Reception F 49 0 40 5 47 02 461 Reception T 49 0 40 5 47 02 102 Customer Service emergency Weinmann Diagnostics GmbH Co KG Always ready System Solutions for Emergency DR ine Agee Hamburg Medicine Transport and Disaster Control F 49 0 40 5 47 02 530 E info weinmann diagnostics de www weinmann diagnostics de Center for Production Logistics Service Weinmann Ger te f r Medizin GmbH Co KG Siebenst cken 14 D 24558 Henstedt Ulzburg T 49 0 4193 88 91 0 homecare F 49 0 4193 88 91 450 Switz
83. onvenient setting options offline or online with fan switched on or off Patented ventilation mode for controlled adaptive ventilation The Weinmann patented Timed Adaptive TA mode provides the best help in unloading the patient s weakened respirato ry muscles A frequent problem in non invasive ventilation NIV is the lack of synchronicity between patient and ventilator during controlled ventilation This results in so called respirator fighting and additional breathing effort which endangers patient therapy compliance Compared to other standard therapies the TA ventilation mode in Weinmann s NIV therapy device VENTI ogic offers greater patient comfort Home ventilation with VENTl ogic delivers significant advantages Optimized synchronization of patient and device nearly eliminates the patient s respiratory efforts In addition simulation of the patient s spontaneous breathing pattern helps to increase therapy compliance while automatic titration of the parameters reduces the workload of clinic personnel WEINM ANN medical technology Technical Data see chapter TD7 Home Mechanical Ventilation SX and SXX Modes The SX and SXX modes in VENTI ogic and VENTImotion give doctors greater flexibility in their use of these therapeutic home care ventilation devices The goal of the two modes is to gradually acclimate the patient to the ventilation settings Most patients who use the devices need controlled ventilation but have
84. or explosion If the ventilator functions properly the EPAP pressure therapy pressure for expiration washes the oxygen out of the exhalation system If the device breaks down however the source of the oxygen which is not connected to the ventilator continues to supply oxygen to the patient This allows oxygen to enter the device at a relatively high concentration which dramatically increases the risk of fire or explosion This risk does not exist with Weinmann s VENTI O In the event of a device breakdown the oxygen valve makes sure that the Supplemental oxygen is released into the ambient air The functioning of VENTI O is simple There are two small tubes in the spiral hose of the ventilator While one of them delivers oxygen to the patient the other measures the pressure The valve responds accordingly Technical Data see chapter TD8 WEINM ANN medical Mtechnology Accessories Home Mechanical Ventilation Analogbox D A Weinmann ventilation devices display the measured data as digital signals The polysomnographic systems in a sleep lab in contrast work with analog signals Until recently it was impossible to display relevant parameters such as pressure flow leakage and respiratory events on the polysomnographic monitor That meant that a doctor had to look at two screens at the same time in order to analyze the data and make his evaluation Data analysis was made even more complicated by the time lag between the
85. or the mouth and nose and the second holds the chin as needed More security results in optimum therapy Effective and secure A mask seal surrounds the nose mouth and chin The two chamber principle a The first chamber covers the nose and mouth as does JOYCE Full Face Consequently we create as before minimum dead space a The second chamber holds the chin without generating an unpleasant flow of air across the chin The lower part of the seal does not lie directly on the chin If the chin should fall it will be caught Air holes prevent sweating SOMNOplus SOMNOplus with integrated exhalation system HEADstrap headgear and EasyClip fasteners With SOMNOplus everything comes pre assembled the treedom of movement mask the integrated exhalation system and the headgear made of breathable material If the patient wants to get out of bed during the night he can separate the hose from the mask with one simple touch SOMNOmask SOMNOmask SOMNOmask blue The mask that lets a patient relax and sleep through the night SOMNOmask allows the patient to move around in his sleep as much as he wants to while the mask stays in place The nasal mask has a ball and socket joint that picks up head movements and gently directs them to the hose The hose can t lift the mask up or cause disruptive leaks Safe and effective Hardly any CO rebreathing Slight pressure sufficient for a reliable seal m Reduced tension on hose
86. orts SOMNO manager System Requirements Input voltage range Processor min Intel Pentium Il 400 MHz or compatible min Intel Pentium Ill 1GHz SOMNOcheck2 analyzable 1V min Intel Pentium IV 2 GHz SOMNO ab Memory min 64 MB RAM 128 MB RAM recommended min 256 MB RAM 512 MB RAM recommended Amplification factor 1 Available memory on hard min 100 MB hard disk drive C min 150 MB for program data disk min 2 8 GB for a recording Precision 4 Drive CD DVD ROM drive optional CD DVD burner CD DVD ROM drive optional CD DVD burner drive drive Isolation voltage Graphics card Resolution supported by Microsoft Windows supported by Microsoft Windows analog port 1500 V AC with a minimum resolution of 800 x 600 with a minimum resolution of 1024 x 768 65536 colors 65 536 colors Input keyboard and mouse or other pointer device Peripheral devices Data transmission baud rate 230400 bauds keyboard and mouse or other pointer device available Windows supported USB port USB Port USB 1 1 optical waveguide Fast Gigabit Ethernet adapter e g WM 98130 Data output to PC Optional peripherals RS232 optical wave guide board for PC WM 98240 serial interface board WM 98250 array MPEG encoder board Brightness sensor photocell WM 98230 optical wave guide TCP IP kit for SOMNO ab WM 98450 Bluetooth adapter WM 95085 USB server WM 95085 LAN video camera WM 98613 Microsoft Windows 2000 starting with SP2
87. osis device it s possible to tell if a disease such as sleep apnea is to blame If the findings confirm the suspicion the patient will be referred to a sleep lab There the patient will be asked for his medical history and will be examined ECG pulmonary function X rays or sonograms and sleepiness test A diagnosis of apnea can be derived from the EEG made during the night and other parameters such as air flow via the mouth and nose eye and leg movements oxygen saturation and snoring noise captured by electrodes and sensors The recorded signals provide information about the different sleep stages and possible apneas and give the doctor information about the type of disease involved Weinmann has developed software that supports doctors in their decisions According to the results of a study carried out in six renowned sleep labs in Europe ARTISANA delivers an excellent analysis of polysomnographic data M Schwaibold Th Ploch W Cassel I Th Penzel H F Becker Multicenter Study on the Variability of the Sleep Stage Scoring Algorithm ARTISANA Compared to Human Experts Part Il Validation Phase Abstract ERS 114s P793 2005 Certified Quality Q Management System meeting EC directive 93 42 EEC Annex II EN ISO 9001 2000 EN SO 13485 WEINM ANN medical Mtechnology EE Sleep Diagnosis SOMNO check 2 R amp K Polysomnography in accordance with international standards SOMNOcheck 2 R amp K permits stationary and
88. port also features a comfortable pressure reduction during exhalation A fixed low background frequency guarantees safe ventilation when apnea lasts longer than 10 seconds BiLevel ST ST spon taneous timed devices such as SOMNOvent ST and the new BiLevel ST 22 distinguish themselves further by an adjustable background ventilation that is activated when spontaneous breathing ceases This combination of patient controlled and ma chine controlled operation provides sufficiently sate ventilation in cases of mixed apnea or Obesity Hypoventilation Syndrome and considerable unloading of the patient s respiratory musculature Technical Data see chapter TD7 WEINM ANN medical technology Home Mechanical Ventilation Accessories Analogbox D A The intelligent connection between Weinmann home mechanical ventilation devices and polysomnography The Weinmann Analogbox D A provides sleep diagnosis data and a visualization of ventilation parameters at a single glance Performance features All diagnosis channels including ventilation parameters at a glance m Permanent channel configuration of the four signals mask The Analogbox converts the digital signals produced by the therapy devices VENTIlogic VENTImotion and BiLevel ST 22 into analog signals which are proportional to the measured data The Analogbox is connected to the therapy device s RS232 interface Up to eight channels in the PSG can be displayed simult
89. ported by MS Windows WEINM ANN medical Mtechnology TD10 Technical Data Oxygen Medicine Technical Data Product class as per 93 42 EEC Dimensions W x H x D in mm Weight Ambient temperature Operation Storage Electrical connection Mean power output and current consumption Fuse Classification as per EN 60601 1 Protection from electric shock Degree of protection from electric shock Sound pressure level Output values after 10 mins operation at 20 C 50 relative humidity and 1013 hPa Output at 2000 meters above sea level at 1000 meters above sea level Outlet pressure Flow rate Warning of abnormal occurrence Electromagnetic compatibility Maintenance Oxygen status OSCI as per DIN EN ISO 8359 warning at lt 82 Vol O Fulfilled product norm OXYMAT 3 lla 400 x 700 x 350 about 20 kg 10 C to 40 C 20 C to 70 C 230 V AC 50 Hz 360 W 1 6 A T25 Ah 2504 as per EN 60127 2 protection class Il type B max 40 dB A 95 1 3 Vol O at 14 l min 90 3 Vol O at 5 l min 90 3 Vol O at5 l min 0 6 bar 60 kPa 0 5 at 5 l min alternative for children 0 2 3 I min scaling in 0 2 increments visual and acoustic radio interference suppression EN 55011 VDE 0875 part 11 radio interference resistance IEC 1000 4 parts 2 6 and 11 once per year after every 5000 operating hours available self test EN I
90. pressure level at the start of expiration and EEPAP pressure level at end of expiration are automatically adjusted to the current needs of the patient Effect and benefit for the patient Ventilation is normalized breathing is stablized and obstruc tions are eliminated in cases of Cheyne Stokes respiration and central mixed or complex sleep apnea syndrome Fast relief While the respiratory fluctuations are balanced out with anti cyclical ventilation the pathophysiological respiration Is modulated in a physiological direction That serves to suppress hyperventilation Central and obstructive breathing patterns are recorded and efficiently regulated for greater therapeutic effect Dynamic reaction to central events Pressure real pressure curve A AE ION set curve IPAP EEPAP EPAP Powerful respiratory support IPAP raised EPAP low CR mode adjusted to needs With normal breathing When the patient breathes normally pleasant pressure relief softPAP is applied Prior to the transition to expiration the therapy pressure is lowered in order to ease the patient s exhalation and increase his comfort In plenty of time before the end of the expiration phase the pressure is again raised to the EEPAP level Obstructions When obstructions are detected epochs with apnea hypopnea flow limitations or snoring the EEPAP is increased to hold the airways open auto EEPAP Technical Data see cha
91. pter TD5 Pressure IPAP EPAP EEPAP The very gentle regulation guarantees sound and restorative Sleep The intelligent algorithm continuously adjusts to the needs of the patient during the night and ensures optimum therapy Normal breathing Hyperventilation phase No respiratory support softPAP CPAP Decreasing tidal volume At decreasing tidal volume hypoventilation phase SOMNOvent CR supports the patient s breathing by continu ously increasing the IPAP EPAP difference Apneas When apneas occur SOMNOvent CR automatically responds with a patient specific frequency like ST mode Increasing tidal volume When tidal volume increases hyperventilation phase the IPAP EPAP difference is reduced to zero in order to quiet and calm the patient s breathing WEINM ANN medical Mtechnology Sleep Therapy SOMNO vent S pe BiLevel S therapy BiLevel therapy allows the patient to exhale freely because the expiratory pressure is lower than and independent of the inspiratory pressure Background frequency ensures added safety The device automatically takes over the patient s triggering when central apnea occurs as in cases of adipose hypoventilation syndrome Restful sleep at every pressure level m Extremely quiet due to unique noise suppression High degree of pressure constancy Comfortable with softstart and autostart Adjustable trigger Background frequency for additional safety SOMNOvent S wit
92. rate flow meter for adults not shown Separate flow meter for children not shown Dosage monitor for adults Dosage monitor for children not shown Adapter for sterile water packs not shown Application systems see below Connection hoses refer to current Weinmann price list PE A T I Technical Data see chapter TD10 11 Accessories Oxygen Medicine EA OXY control 2 Oxygen dosage monitor with bubble humidifier and flow meter Accessories OXYBAG Hit OXYTRON 3 CYPRESS 2 0 liter cylinder 0 8 liter cylinder 2 0 liter lightweight aluminum cylinder 3 in 1 Transport Bag Caddy Application systems see next page Accessories for OXYBAG Hit Pressure reducers OXYWAY Fine Fine Il Fine Ill Fast Fast Il refer to page D5 not shown OXYTRON 3 Accessories OXYTRON 3 battery pack not shown OXYTRON 3 charger not shown OXYTRON 3 spiral hose OXYTRON pressure reducer OXYTRON 3 continuous flow adapter not shown Application systems see next page WEINMANN medical Mtechnology DB Oxygen Medicine Accessories OXYFLOW Basic and t OXYFLOW Revi Accessories E Pressure reducers OXYWAY Fine Fine II Fine Ill Fast ne Fast Ill Eai PONY safe transport trolley with five casters Cylinder jacket light gray 10 liter cylinder OXYFLOW Revi Accessories COMBIBAG resuscitator with oxygen reservoir and inhalation mask for adults Oxygen administrator with three outlets OMNIV
93. ration storage humidity Output voltage range Short circuit proof Overvoltage protection Allowable leading load Max allowable amount Max allowable operating pressure Max allowable flow flowing out freely Minimum required O primary pressure at valve opening for 4 l min O Max allowable static pressure of pressure source Allowable therapy pressure Maximum mask temperature Gas leakage at 30 hPa Pressure drop at a flow of 50 l min at a flow of 100 l min at a flow of 150 l min User setting which results in 100 rel humidi ty at the patient connection port at ambient rel humidity 70 flow 20 l min room temperature 15 C 18 C 23 C Supply cable pin assignment Display precision Switch on threshold Switch off threshold VENTI click lla 120 x 120 x 155 mm 265 9 operation 5 C to 35 C storage 40 C to 70 C 600 1100 hPa 40 V DC 24 VA degree of protection from electric shock type B EN 55011 EN 61000 3 2 EN 61000 3 3 EN 61000 4 2 to 6 EN 61000 4 8 EN 61000 4 11 lt 95 relative humidity 300 ml 40 hPA 300 l min 38 C not measurable 0 5 hPa 1 7 hPa 3 8 hPa setting 6 Analogbox D A with VENTImotion VENTI ogic Channel Messure value Channel 1 mask pressure Channel 2 flow Channel 3 leckage flow Channel 4 tidal volumes Channel 5 unassigned Channel 6 unassigned Channel 7 unassigned Channel 8 unassigned WEINM medical NN t
94. receive oxygen at least 16 hours per day generally by means of a nasal cannula Various oxygen systems are available Oxygen concentrators are intended mostly for use by patients at home They filter oxygen from the ambient air and supply it to the patient via a hose system Mobile patients can use a lightweight oxygen conserving system that can be carried in a backpack or a shoulder bag Certified Quality y Management System m meeting EC directive 93 42 EEC Annex II EN ISO 9001 2000 EN SO 13485 WEINM ANN medical technology Dz Oxygen Medicine OXYMAT 3 The best therapy partner at home The oxygen concentrator OXYMAT 3 features service friendly modular construction whisper soft operating sound and several equipment options OXYMAT 3 is available with a OXYMAT 3 with flowmeter OXYMAT 3 with oxygen dosage monitor easyOX easyOX duo easyOX For efficient oxygen therapy True to its name the easyOX for stationary long term oxygen therapy is easy and convenient to use and offers all the essential functions of an oxygen concentrator The efficiency of the oxygen therapy is continuously monitored by means of an integrated ultrasound oxygen sensor Available in two models as a single flow meter for one patient at home or as a double flow meter for two patients in a hospital WEINM ANN medical Mtechnology portable oxygen dosage monitor or a flow meter on the oxygen outlet Both device m
95. ressure range Weight Temperature range Flow resistance Sound pressure level at 10 hPa Usable life Material 1 hPa 1 mbar WEINM medical NN technology JOYCE Full Face lla about 107 x 160 x 106 mm about 102 g mask seal soft 4 30 hPa mask seal hard 4 40 hPa cone as per DIN EN ISO 5356 1 JOYCE Full Face vented 22 mm male JOYCE Full Face non vented 22 mm female 4 mm max 20 mm operation 5 C to 40 C storage 20 C to 70 C JOYCE Full Face at 50 l m 0 02 hPa at 100 I m 0 26 hPa JOYCE Full Face NV at 50 l m 0 09 hPa at 100 l m 0 37 hPa at 50 l min 0 5 hPa at 100 l min 2 0 hPa 27 5 dB A open lt 2 hPa closed lt 1 hPa 6 to 12 months depending on frequency of use and cleaning mask seal silicone LSR forehead cushion TPE PP mask body polycarbonate PC forehead support polypropylene PP seal for ports silicone LSR rotating sleeve polypropylene PP safety ring TPE PP elbow polycarbonate PC headgear clip POM valve cartridge TPE PP HEADstrap polyester lycra polyurethane nylon spandex All parts of the full face mask are latex free SOMNO mask lla about 80 x 140 x 90 mm about 50 g 4 30 hPa JOYCE lla about 80 x 130 x 90 mm about 85 g mask seal soft 4 30 hPa mask seal hard 4 40 hPa cone as per DIN EN ISO 5356 1 JOYCE vented 22 mm male JOYCE non vented 22 mm female 4 mm max 20 m
96. retention even in event of power loss RS232 to PC with charger WM 94060 quick charge within 120 minutes approx 500 charges possible for discharged power pack and during charging stand by sensor test recording data transmission at loss of sensor and at start of recording stand by mode sensor integrated in device right side left side abdomen back standing about 45 15 CPAP BiPAP SmartPAP Pressure Measurement range Precision 0 20 hPa 0 2 hPa Pulsoximeter Clipsensor SpO measurement range SpO precision Pulse rate measurement range Pulse precision 50 99 at SpO above 85 1 5 percentage points at SpO between 75 and 85 at SpO between 50 and 75 30 to 250 bpm 1 Respiratory Flow Snore Sensor Respiratory flow snore sen Range Snore sensor Method Range sor three thermistors as total signal no measurement func tion at ambient temperatures between 33 C and 38 C 8 bit integrated microphone logarithmic mean of inspiratory snoring noise 8 bit Respiratory Flow Snore Nasal Cannula Respiratory flow snore nasal cannula difference from ambient air pressure resolution to 10 hPa Sensor Method Range Snore Method Range flow approximation through square root calculation 8 bit difference from ambient air pressure bandpass filter 30 250 Hz logarithmic mean of inspiration signal 8 bit Respiratory Flow Mouth Sensor Respiratory flo
97. ry high level results The quality of the analysis has been validated by a multi center study which was conducted in six renowned sleep labs in Europe Multi center study The multi center study guarantees that ARTISANA will analyze your recordings with quality comparable to that of the leading European sleep labs in Barcelona Berlin Grenoble G teborg Palermo Turku ARTISANA stands for Artificial Intelligence in Sleep Analysis The software based on neuronal network technology was implemented with the help of leading sleep medicine experts Because ARTISANA mimics human thought processes it can be certain or uncertain about its decisions By making its self evaluation available ARTISANA allows the user to concentrate on the phases of the recording in which the system was uncertain perhaps because the signal contained artefacts op ipa ripe min RR cbk MATE stare JO Le Ja re e data a morta ra if pre a Level of confidence a higher value corresponds to a higher degree of certainty Software Sleep Diagnosis EE ARTISANA lets the user see and understand why it made a decision about a particular sleep stage The user can follow the reasoning or correct the decision if he draws a different conclusion from the raw data The new sleep apnea software ARTISANA has been available as a component of the proven WEINMANN PSG system SOMNO ab since autumn 2006 ARTISANA analyzes data trom SOMNO ab SOMN
98. s in nursing homes and doctors practices OXYBAG Hit The equipment includes the OXYWAY Fine pressure reducer with content and flow gauge for infinitely variable dosages em from 3 to 15 liters minute a 2 liter oxygen cylinder an inha Spa 4 gt lation mask and the Weinmann 3 in 1 transport bag Other TES 5 Me gt pressure reducers and pediatric application systems are also available OXYBAG Hit with 2 liter oxygen cylinder In comparison O concentration in the airways Oxygen Example The set flow rate is 6 liters minute respiratory minute volume is 10 liters minute use of inhalation mask with concentration breathing bag According to the diagram the result is an oxygen concentration of about 65 100 80 60 42 litersimin Respiratory volume 40 20 0 5 10 15 l min Flow rate Technical Data see chapter TD10 WEINM ANN medical Mtechnology OXYWAY Especially safe Especially precise Especially flexible Weinmann s OXYWAY pressure reducers stand out with their high degree of safety and precision and their variety of models Intended for use in oxygen and emergency medicine the versatile pressure reducers are small light precise and easy to operate Performance features m Greatest operating safety ensured by ultrasound tested high pressure housing double sinter filter and explosion protected gauge Highest precision in flow dosage over the entire cylinder pressure range
99. s to the patient s own breathing and automatically adjusts the pressure according to the patient s needs within the therapy range pre viously prescribed by the doctor BiLevel therapy on the other hand is suitable for patients who have high pressure requirements It offers two different levels increasing pressure during inhalation and decreasing pressure during exhalation Patients appreciate the reduced pressure which allows them to exhale more easily and to improve their compliance as a result CS therapy is suitable for treatment of heart failure patients with Cheyne Stokes respiration or with central mixed or O complex sleep apnea syndrome It works to normalize the patient s breath Certified Quality F a x Management System ing and to eliminate obstructions at the same time all of which effectively meeting EC directive 93 42 EEC Annex II EN ISO 9001 2000 EN SO 13485 improves the patient s sleep WEINM medical technology ES Sleep Therapy SOMNOcomfort 2e with SOMNOaqua CPAP20e Basic therapy for sound sleep Weinmann s best priced CPAP20e guarantees effective CPAP therapy and thus healthy sleep User friendliness and econ omy are the watchwords for the simple and efficient operating functions CPAP20e with humidifier CLICK 2 WEINM ANN medical Mtechnology SOMNO comfort 2e CPAP therapy Your sleep in top form SOMNOcomfort 2e is the enhancement of the exceptionally successful SOMNO com
100. stic system with a pre configured and system tested visualization and analysis system For efficient work in the sleep lab m Quick hardware application on the patient headbox and bodybox are applied directly on the patient m Impedance measurement and application check of the electrodes take place on site Complete freedom of movement and independence for the patient thanks to the simple disconnection and reconnec tion of the transferbox at the bedside Recording of all standard parameters as defined in the na tional and international guidelines AASM DGSM Bodybox and Headbox Easy handling Technical Data see chapter TD2 Sleep Diagnosis ES SOMNOcheck effort is an outpatient device for sleep diagnosis and therapy monitoring The software offers programmable recording periods fast data transmission automatic analysis function with manual editing capability and selectable analysis criteria m Recording parameters respiratory flow snoring heart rate oxygen saturation body position and if necessary nCPAP pressure m Recognizes apnea hypopnea oxygen saturation heart rate variations and provides nCPAP therapy monitoring in addition to screening m Records thoracic and abdominal movement of the patient and distinguishes between central obstructive and mixed apneas s equipped with a pulse oximetry sensor and a combo sensor for respiratory flow and snoring noise m Hardware can be easily att
101. terchangeable CF card almost unlimited mobile use All recording technology is integrated in the housing even two thorax effort sensors There are no external connections Four electrophysiologic channels to be configured as ECG EMG EEG or EOG Additional functions m Additional invoicing for ECG and EMG Patient oriented application assistance for outpatient use m Wireless data transmission in online use m Intelligent battery pack prevents mismeasurement Integrated recording functions Recording parameters respiratory flow snoring heart rate oxygen saturation body position pressure CPAP BIPAP smartPAP Four electrophysiological channels available for ECG and leg EMG for example plus any other configuration E Integrated effort sensor piezo crystal technology High quality of ventilation therapy monitoring due to differential pressure measurement Clear data preparation Online representation of recording on a PC m Can be used with SOMNO ab and SOMNO manager software Technical Data see chapter TD2 SOMNO check effort Simple diagnosis and therapy monitoring system for sleep related respiratory disorders SOMNO ab Complete diagnosis station for individualized patient care The SOMNO ab sleep diagnostic system reduces routine work in the sleep lab and frees up more time for patient care To ensure enough computing capacity for the configuration Weinmann delivers the SOMNO ab sleep diagno
102. the patient connection port at ambient rel humidity 70 Flow 20 l min room temperature 15 C 18 C 23 C SOMNOsupport System requirements SOMNO click 300 lla 120 x 85 x 155 mm WxHxD 2209 operation 5 C to 35 C storage 20 C to 70 C 30 V DE 15 VA type B EN 55011 VDE 0875 T11 IEC 1000 4 parts 2 6 11 700 1060 hPa 300 ml 30 hPA 180 l min 36 C not measurable 0 5 hPa 1 9 hPa 4 1 hPa setting 6 SOMNO aqua lla 140 x 100 x 121 mm WxH xD 300 g operation 5 C to 35 C storage 40 C to 70 C 30 V DC 15 VA type B EN 55011 B IEC 1000 4 parts 2 6 11 700 to 1060 hPa 300 ml 30 hPA 160 l min Bacteria filter lla 74 x 98 mm x L about 51 g operation 5 C to 40 C storage 20 C to 70 C max 0 5 dB A 700 1060 hPa 3 35 hPa 300 l min 85 ml lt 24 hrs PE 134 C Converter box O Valve lla 45 x 85 x 30 mm W x H xD 1259 operation 5 C to 40 C storage 20 C to 70 C protection class Il type B EN 55011 EN 61000 4 parts 2 6 11 700 1060 hPa lt 4 l min O 7 15 V DC in operation 96 0 mA in standby mode 8 5 mA 250 hPa 1500 hPa 4 30 hPa Converter cable USB RS485 Technical Data Device class EC 93 42 lla lla Dimensions WxHxD 135 x 55 x 30 mm 70 x 40 x 20 mm Length of USB cable 250 mm Weight approx 100 g approx 50 g Temperature range 10 C to 40 C
103. therapy parameters with the SOMNOadjust module Analysis of therapy course and report on therapeutic efficiency liaui AI ASA AA EII nrp E Weekly compliance and detailed pressure and event Diagram of titration night with course for the selected day signals and events Starting December 2007 WEINMANN support one package for everything An integrated PC software package will be available for all SOMNO and VENTI therapy products graphic visualization monitoring and analysis of patient compliance daily statistics numeric and graphic representation statistical analysis 365 days of compliance data remote setting of therapy parameters More information is at www weinmann de Technical Data see chapter TD6 WEINM ANN medical technology EM Sleep Therapy Accessories Heated humidifier SOMNOclick 300 Heated humidification for maximum compliance Many sleep apnea patients suffer from dried out mucous membranes The symptoms range from unpleasant dryness to inflammations and bothersome nosebleeds and seriously jeopardize patient compliance Help can be found in the heated humidifiers SOMNOclick and SOMNO aqua The WEINMANN heated humidifiers are equipped with a large water tank which holds about 300 ml for patients with greater respiratory volume or pronounced mouth breathing The heating or humidification settings and power supply are man aged on the device itself The humidifiers are easy to fill
104. tion as per EN ISO 17510 in patient position at distance of one meter from device Air pressure range Pressure constancy measured as per EN ISO 17510 Operation storage humidity o PA EE 5 s dl MN E Therapy pressure range Background frequency Respiratory rate Modes Softstart Pressure ramp speed Trigger threshold Flow at max speed at Fine filter separation level Fine filter service life Serial interface RS 485 Analog port Maximum marginal pressure for first error Heating of respiratory air as per EN ISO 17510 Signal feed 1 hPa2 1 mbar ATT SOMNO vent CR lla about 3 4 kg 115 230 V AC 10 50 60 Hz or 12 24 V DC with AC converter WM 24131 or WM 24132 Technical Data Sleep Therapy SOMNO vent S SOMNOventST SOMNOset lla lla lla 180 x 90 x 320 mm about 4 0 kg about 4 0 kg about 3 6 kg 5 C to 35 C 20 C to 70 C 115 230 V AC 50 60 Hz or 12 24 V DC with converter WM 24131 or WM 24132 in order to guarantee the pressure consistency required in HMV a maximum voltage drop of 10 is allowed Operation 15 VA operation standby operation standby operation standby 0 1A 0 015A 0 1A 0 015 A 0 1 A 0 015 A 0 2 A 0 03 A 0 2 A 0 03 A 0 2 A 0 03 A 19A 0 29 A 1 9 A 0 29 A 1 9A 0 29 A protection from electric shock protection class Il degree of protection from electric shock type B Test parameters and limitscan be requested from the m
105. tion technique made possible by SOMNOset puts you a critical step ahead in terms of process improvement and titration quality SOMNOset is your reliable and precise assistant in determining the required CPAP therapy pressure Based on the unique CPAP technology of the proven Weinmann device SOMNOsmart 2 the new SOMNOset processes all respiratory events with great precision and reliability Flow and snore signals and the Oscillatory Pressure Signal OPS are analyzed and stored as events e g obstructive central apnea SOMNOset with bacteria filter obstructive central hypopnea snoring flattening Leakage detection and artefact recognition ensure high quality analysis Economical Cost and time savings as a result of optimized processes Flexible leaving more time for patient instruction and mask All necessary titration modes in one device auto titration adjustments pressure profile APAP auto CPAP and CPAP m Recommended titration pressure at the push of a button Remote setting with SOMNOadjust or SOMNOsupport Split Night The recommended titration pressure can be activated after three hours Simple operation and familiar accessories as with Weinmann Top level titration quality at any time reproducible and therapy devices SOMNOcomfort and SOMNOsmart 2 understandable Objective m Hygienic treatment at change of patient not required Analog signals for PSG input flow pressure OPS leakage bacteria filter
106. to the patient s desired level of humidification Maximum safety Clear presentation m Visual and acoustic alarms IPAPmin Vtmin power loss m Numeric and graphic monitoring of ventilation parameters disconnection overpressure overheating implausible pressure Flow and volume curves online in display measurement Display of changes between spontaneous and mandatory respiratory phases Oxygen delivery via the click on connecting valve VENTI O puts oxygen supply close to patient Back up power independent of mains supply with VENTloower with minimum operating capacity of five hours Innovative filter concept with high filtration efficiency of 99 7 at particle size of 2 um and a long service life of 1000 hours m Weinmann hygiene concept for reconditioning at change of patient in accordance with recommendations for hygienic handling of home mechanical ventilation devices issued by the industry group SPECTARIS according to the guidelines issued by the Robert Koch Institute for the hygienic care of home ventilation devices Statistical data annual compliance Daily compliance Standard display Menu management with analysis doctor s menu windows Statistical data weekly compliance over the course of a Patient compliance Language selection menu Flow curve including changes Display of ventilation Statistical data between spontaneous and p
107. urs Graphic analysis with PC software SOMNOsupport and extensive diagnostic information for therapy monitoring and compliance data therapy calendar m Intelligent and powerful algorithm for automatic adjust ment of three pressure levels IPAP EPAP and EEPAP to the current needs of the patient with differentiation between obstructive and central events Simple setting of parameters a IPAP and EPAP regulation for adequate pressure reaction to periodic breathing or CS respiration m Remote setting with SOMNOagjust or SOMNOsupport Auto CPAP functionality for adjustment of EEPAP upon recognition of obstructive events autoEEPAP Analog signals for PSG feed flow pressure leakage m Maximized ventilated breath with sinking of EPAP Automatic or pre set background frequency SOftPAP pressure relief during normal breathing for maximum comfort and improvement of compliance Heart failure and sleep related breathing disorders At least 1 3 million people in Germany suffer from heart failure according to the University of Wurzburg and every year another 116 000 cases are added to that number Worldwide the number of people affected is 22 million reports the University of Zurich some 1 5 million of whom die each year from complications associated with heart failure Given the increase in the portion of older people in our society the number of heart failure patients will also rise significantly according to the German So
108. w mouth sensor Therapy monitoring Effort Sensors Effort Thorax and Abdomen Range Thorax Sensor Method SOMNOcheck 2 R amp K trunk cable and EKG trunk cable EEG ExG channel mask pressure measurement with pressure measurement hose piezo sensor 8 bit piezo sensor piezoelectric measurement R amp K EOG EKG Channel Dynamic range physical range of values 500 pV 500uV 500 pV Dynamic range l physical range Resolution 12 Bit 12 Bit 12 Bit Resolution Amplitude precision 3 3 3 i Lower frequency limit SUS 0 2 70 Hz 0 2 70Hz 0 05 70 Hz pedal hardware j j j Upper frequency limit High pass in device 05 Hz 0 5 Hz 0 02 Hz pp q y software a Precision Precision 3 3 3 eee Scan rate 256 Hz Can be set Inlet impedance about 40 MQ Specifications NOTE 1hPa21 mbar WEINM medical These channels are permanently configured Port impedance NN technology 2 percentage pts 3 percentage pts SOMNOcheck 2 electro physiological signals SOMNO check 2 SOMNO check 2 R amp K lla 80 x 150 x 34 mm about 300 g device without sensors about 340 mW wireless online about 10 hours portable about 20 hours depends on CF board used standard 128 MB via USB cable or Bluetooth Ladung in max 3 Std auch extern power pack status memory board status execution and results of sensor and impedance tests communi cation with PC s
109. will be available for all SOMNO and VENTI therapy products graphic visualization monitoring and analysis of patient compliance daily statistics numeric and graphic representation statistical analysis 365 days of compliance data remote setting of therapy parameters More information is at www weinmann de Technical Data see chapter TD9 WEINM ANN medical Mtechnology Oxygen Medicine DN OXYTRON 3 Oxygen Medicine Long term oxygen therapy to regain quality of life A severe and lasting oxygen deficiency in arterial blood is called hypoxemia Patients with this condition can experience respiratory distress and exhaustion after even the slightest physical exertion Pressure builds up in the pulmonary arteries in such a way that the walls of the blood vessels thicken That in turn blocks gas exchange and makes oxygen deficiency in the blood more severe Increased intrapulmonary pressure also leads to an overburdening of the right heart musculature which can result in heart failure Hypoxemia can be triggered by pulmonary embolisms pulmonary fibrosis emphysema thorax deformation or cardiac insuffi ciency Through long term oxygen therapy the quality of life for persons so affected can be improved Treatment gives many of them enough breath so that they can once again move around almost normally Their increased movement counteracts muscle loss due to the immobility caused by hypoxemia For effective therapy the patient must

Download Pdf Manuals

image

Related Search

Related Contents

Installation and Owner`s Manual  My Book® Essential - User Manual  Manual - Soler & Palau  Guide de l`utilisateur/ Guida dell`utente/Soluzione  Polaris 6x6 Offroad Vehicle User Manual  Zotac ZBOXSD-ID12-U barebone  EM-13, "Checking Drive Belts"  Desktop Reference  InnoPet IPS-010 Precious User's Manual  