AIRREX AIR CONDITIONER
Contents
1. AIRREX AIRREX AIR CONDITIONER MODEL HWC 15 gt Thank you for purchasing Airrex Portable Air Conditioner Please read the instructions thoroughly before operating After reading the instructions please keep them in a safe place accessible to all users gt Ensure you read the safety precautions in advance and use the product correctly gt The product is specified for use with a power supply of 15 6OHZz This manual includes the product warranty gt Specifications and contents of this manual may be changed without prior notice in accordance with our commitment to product quality improvement design and control Le AIRREX CONTENTS SAFETY INSTRUCTIONS PRECAUTIONS FOR USE NAME OF PARTS MAIN BODY gt CONTROL PART HOW TO USE HOW TO OPERATE SELECTION of ROOM or SPOT COOLING TEMPERATURE CONTROL ERROR INDICATION HOW TO INSTALL amp PRECAUTIONS CLEANING AND MAINTENANCE TROUBLE SHOOTINGS SPECIFICATIONS amp ACCESSARIES WARRANTY AIRREX SAFETY INSTRUCTIONS These are contents for keeping the safety and preventing the property damage Please read and use correctly Precautions at this page are for the safe and correct use of the unit and for the preventing a danger and damage of the operator or others With regard to the contents these are classified into WARNING and CAUTION These are important for the safety so plea
2. Handle Digital controller Air intake hole Evaporator Indoor unit Filter The place where indoor air enters Casters for moving This unit can be moved freely anywhere Back Side Connecting hole for discharging water The place where water of the heat exchanger is discharged Connecting hole for supplying water The place where water is supplied to the heat exchanger Drainage of condensed water The place where condensed water collected in the drain pump installed inside is drained Power cord Electricity panel The place where electricity control panel is installed inside LS AIRREX AIR CONDITIONER NAME OF PARTS Control Part ROOM SPOT SETTING D High Pressure Low Pressure Sensor Error Anti Freezing Water Full 2 9 AIRREX POWER It is used for ON OFF 0 Air Volume Control High and Low for the discharging air volume Initial setting High Cool It is used for choosing the cooling and blowing operation and when in cooling operation it is automatically controlled in accordance with the set temperature Initial setting Cooling operation 4 Cooling Lamp It lights on when choosing the cooling operation Temperature Control For controlling the setting temperature choose UP DOWN COMP Lamp It lights on when the compressor is operated Room Lamp It lights on when the room temperature is shown or the unit is op
3. WARRANTY Applicable to first retail purchaser only AIRREX WATER COOL AIR CONDITIONER give more reliable performance comfort and durability the more they are used They are built under a strict quality assurance regime which includes inspection both during and after production and exhaustive reliability testing In the unlikely event you have any problems please contact your dealer or distributor If the problem is as a result of a production fault or failure repairs will be undertaken free of charge during the period of warranty subject to the following warranty conditions 1 The warranty period is 12 months from the date of first purchase 2 If the problem has been caused by customer error or misuse abuse or damage then all repairs will be charged for 3 Proof and date of purchase must be supplied 4 Please complete the details below and keep this warranty in a safe place 5 All transport charges back to the dealer are at the customers cost Keep all original packaging to facilitate return Return to customer will be at dealers cost if genuine warranty claim DESCRIPTION AIRREX WATER COOLED AIR CONDITIONER MODEL HWC 15 mows Name of Company DISTRIBUTOR Telephone No CUSTOMER AIRREX lt USA DISTRIBUTOR AIRREX USA P O BOX 340 HEWITT TEXAS 76643 TEL 888 244 5898 FAX 469 574 7924 E mail sales airrexusa com Website www airrexusa com HEPHZIBAH CO LTD 1385
4. F like that Lo for the below 32 F and Hi for the over 99 F Error Indication In case of a trouble during operation various safety devices amp sensor work and the state is shown at the indication part ROOM SPOT SETTING Check the High Pressure HP or Stop the Water Supply lf the pressure of compressor becomes high the high pressure sensing switch works and the compressor stops then is shown Check the Low Pressure LP lf the pressure of compressor becomes low the low pressure sensing switch works and the compressor stops then E2 is shown ROOM SPOT SETTING Ch ck the sensor lf the temperature sensor is cut or short circuit E3 is shown and at this time the compressor works normally ROOM SPOT SETTING Check the anti freezing AF lf the sensor is sustained below 25 F for preventing the freezing of the evaporator the compressor stops and AF is shown ROOM SPOT SETTING Check the water overflow lf the water full sensor installed inside of the discharging pump senses it the compressor stops and FU is shown ROOM SPOT SETTING AIR CONDITIONER AIRREX HOW TO INSTALL amp PRECAUTIONS Selection of the Installation Place As the air conditioner should be connected with the tap water tube its installation near the hydrant is good Install it on the even and stable place How to Connect Pipes 1 Connect the nipple at the wa
5. in good state without fail Do not connect it to the gas pipe water pipe or telephone line 2 Connect the power source of the air conditioner to the exclusive cable or the correct voltage 3 Do not connect the power line in the middle or extend it Electric shock or fire may be caused 4 Do not install the unit at the place of an inflammable gas leakage or heat of fire If the leaked gas is accumulated around the air conditioner a blast or fire may be caused 5 Note that if the drain hose is unstably set water cannot be drained 6 The standard pressure of water in taking of this product is 28 71psig When the pressure exceeds the standard install a decompression device and in case of lower pressure than the standard install a separate device Pressure pump etc 7 When installation the standard part supplied with the air conditioner should be installed 8 For piping for water in taking or discharging a hose may be used for a short distance 3 33 ft and for a long distance more than 33 ft a proper material Matchable X L pipe should be installed in principle 9 Connect the pipe correctly not the direction to be changed with the discharging one 10 The exposed in taking pipe should be thermally insulated Condensation prevention of in taking water and the prevention of freeze break in winter season 9 AIR CONDITIONER AIRREX CLEANING AND MAINTENANCE Cleaning
6. supply valve Rated voltage of this product is 115V 60Hz Connect to the rated power source and the earthed outlet Make sure the safety of the place to be used Do not touch the power cord with a wet hand When moving this product do not lean more than 30 or topple it When operating keep it horizontal or in unavoidable situation keep it less than 2 Do the exclusive power circuit for the air conditioner Do not pull the power cord If the power cord is damaged a fire or electric shock may be caused Use the standardized fuse without fail 8 Operate efficiently the unit under the shadow and avoid operation in the temperature higher than 113 F Keep space more than 8 inch around the air intake so that a smooth in taking of air can be done 10 As dust in the filter or the heat exchanger deteriorat the cooling do clean the filter of the heat exchanger regularly 11 When using the product use it indoor place free from direct sunlight When thunder lightning for a long time pull the power plug out of the outlet Electric shock leakage or fire may be caused When inserting pulling out the power plug grip the plug A fire may be caused by electric shock or short circuit Do not spray water on to the cooler nor use solvents such as benzene thinner or alcohol for cleaning There is a risk of electric shock and or short circuit Excessive cold wi
7. 15 JUAN DONG NAM GU INCHEON KOREA TEL 82 32 509 5834 FAX 82 32 502 5519 E mail airrex hdtek com Website www airrex co kr Designs and specifications of products are subject to change without prior notice for the improvement of products
8. erated by the room temperature Current Temperature or Error Lamp It shows the spot or room temperature When a trouble occurs during operation it shows the error state information E1 High Pressure E2 Low Pressure E3 Sensor AF Prevention of Freezing FU Water Overflow Set Temperature It shows the set temperature desired A AIR CONDITIONER AIRREX HOW TO USE How to operate 1 Operation amp Stop Confirm that the power cord is connected to the outlet Press the Power button and the operation starts automatically ROOMI SPOT SETTING At this time it is operated as the basically Cool mode and Fan speed High While operation press the Power Button and all operations will be stopped High Pressure Low Pressure Sensor Error 2 Air Volume Control Anti Freezing N Water Full By pressing the air volume control button while operation choose the desired air volume At this time in case of strong F Lo in case of weak is shown for one second 3 Cooling amp Blowing Operation Whenever pressing the Cool Button the cooling or the blowing operation can be chosen When the cooling operation is chosen the Cool Button lights on the cooling operation is chosen while the blowing operation fa the compressor may start in 3 minutes for the protection of AIRREX the compressor When the compressor is run during the cooling operation the Comp Lamp ligh
9. nd may be harmful to health Do correctly the grounding device work without fail However do not connect to the gas pipe water pipe or telephone line If the grounding device is not set a trouble or electric shock may be caused 12 Do not use this product as a means of moving other heavy goods or as a carrier of man 13 Do not insert any foreign substance can bottle of drink into cold air discharge hole It may damage the product 14 Do not put an obstacle in front of the air intake hole Trouble may be caused 15 The optimum distance between the worker and the discharge duct is less than 80 inch 16 When use fix the locking device of front wheel at For release press OFF 17 Do not use it when water supply is stopped When water stoppage re operating is possible up to 2 times and in case of water stoppage or shortage the error E1 is shown and the operation will be stopped 18 If the water supply is low the product cannot be normally operated and main parts may be damaged 19 Discharged water is in state that removed indoor heat is added to the pure tap water thus the waste heat can be re used for other purpose But it cannot be used as drinking water A AIR CONDITIONER AIRREX changed without prior notice N AME OF P ARTS For the efficiency improvement of this product the specification may be Front Side Discharge Duct The place where cold air comes out
10. r leaked do not operate the unit When cleaning pull out the plug without fail An electric shock may be caused Do not connect other power outlet or do not Do not randomly disassemble or remodel other home appliance by using extension the product cord A trouble electric shock or fire may be caused Do not insert a finger or stick into blowing hole CD In case of a strange sound or smell in the air 00202220G Hurt may be caused so give a waring conditioner stop the operation and cut off to children the power and contact the Service Center A continuous operation in abnormal condition a trouble electric shock fire may be caused After reading carefully keep it where any user may see it anytime LS AIRREX SAFETY INSTRUCTIONS N AUTI ON For the damage occurred due to non keeping of following matters the manufacturer is not responsible for the compensation Do not install the product on the uneven or slant place For safekeeping avoid hot humid place and keep it in dry indoor place Rusting or trouble may be caused In case of power cord s damage contact A S Center for changing it Electric shock or fire may be caused Dot not step on the product or put a thing on it Trouble or electric shock may be caused During operation do not pull off the water supply hose or the drain hose Water leakage or fire damage may be caused For preventing water leakage close the water
11. re too high Measures to be Taken Insert the plug Press ON OFF switch and confirm the lamp condition Change the fuse of electric panel After confirming the load capacity raise the circuit breaker of the distribution panel Use it at the place of 113 F and lower Request an electricity construction company for the available rated voltage Clean the filter Washing with water is OK Clean the heat exchanger Remove the obstacle Farther than 8inch For cooling adjust the set temperature lower than the ambient temperature Confirm the water supply valve is opened Confirm that after 3 minutes the compressor is normally operated and the cold air is being discharged the humidity is high much air is discharged and white vapor may be emitted is a phenomenon that the moisture the air is changed into dew and this is not abnormal 62 AIRREX SPECIFICATIONS amp ACCESSARIES MODEL 15 Cooling Capacity 13 800 Btu h Power Supply 115Va c 60Hz Size WxDxH 17 5 X 22 5 X 42 inch Weight 159 Ibs Power Consumption 1 1 kW Refrigerant R410a_ 1 1 Ib AIR Filter Aluminum Filter Devi High Low Pressure Switch Thermostat Protector for Compressor Safety Device amin Delay Timer Plug Type 9 8 Power Cord 72 F DB 60 RH 113 F DB 40 RH 30ft 2 9 GPM DRAWING DUCT COVER DAMPER BASE ALUMINIUM FILTER CASSETTE 13
12. se observe them without fail WARNING This is the content that when a faulty handling is done a person s death or heavy injury is expected CAUTION the content that when a faulty handling is done a person s injury or property damage is expected Meaning of the figural symbol S indicates a prohibition indicates a matter that must be done without fail ARNING As for a damage that occurs during the following cautions the manufacturing company cannot be responsible for the compensation Use an outlet for exclusive use of alternative current 115V A fire or electric shock may be caused After wipe out dusts from the power plug insert it correctly into outlet Due to electric shock or short a smoking or fire may happen Do not use a damaged electric cord plug or loosened outlet An electric shock short or fire may be caused Use a rated capacity fuse A trouble or fire may be caused Do not pull out the cord or touch the power plug with a wet hand Do not forcibly bend the cable or be pressed by a heavy thing for not being damaged An electric shock fire may be caused Do not connect or extend a power cord in the middle of it An electric shock fire may be caused Electric shock or fire may be caused Insert a cord into the outlet with earthed terminal In case of common outlet set a separate earth terminal without fail When water supply is stopped o
13. ter in taking hole and the water discharge hole of the backside of the air conditioner At this time wind the Teflon tape at the thread part and fasten it the main body Op 0 00 Hose 2 Unfasten the nut and ring at the nipple and connect it to the hose and insert the hose into the nipple and fasten it by using the nut When connecting the hose make the cut surface of the hose even 3 Connect the water in taking hole to the tap water tube or a pressuring pump and the water discharge hole to the drain hole Pay attention for not changing the water in taking hole with the discharging hole 4 Connect the discharging hose with the condensed water discharge hole and to the draining hole The Sink R Tap water nozzle m I T type tube WATER OUT WATER IN Tap water tube 5 Once the pipe connection is finished open the valve of water supply line so that water is supplied At this time as water is discharged only when the air conditioner is operated check whether water is discharged from the drain hole 9 AIRREX HOW TO INSTALL 8 PRECAUTIONS Check Points after Installation After confirming the state of pipe connection check whether a leakage is at the connection part Confirm whether the connection of the drain hose is good Confirm whether the earth line is good 10 Precautions for Installation 1 Do the earth line work
14. the Air Filters and Maintenance Cleaning of filter Detach the filter from the A C Cleaning of heat exchanger Clean dust attached and clean it with compressed air or water to the heat exchanger with compressed air or a vacuum cleaner 1 After cleaning dry well the inside 2 After stopping operation and 3 Note that moisture and dust not by blowing operation for pulling out the power cord to enter into the unit 3 4 hours do wind well and fix the cord X When it is not used close the valve of the water supplying line and discharge the water in the line and keep it after being dried 11 LS AIRREX TROUBLE SHOOTINGS Symptom The operation is not done The cooling is not well done When white vapor is generated during operation When dew is formed at the discharging hole 12 Check Points 5 the power plug pulled out 5 the operation stopped 5 the fuse cut 5 the circuit breaker fallen 5 the surrounding temperature too high Higher than 113 F Is the voltage too low 5 the filter clogged with dust Although the filter is clean is the heat exchanger clogged with much dust 5 there any obstacle in the in taking part 5 the set temperature correctly set Is the water supply cut Right after the operation stops is the unit started to operate instantly 5 the unit being used where humidity is high 5 the room temperatu
15. ts on Selection of Room or Spot cooling the transfer the Room Mode press the Cool Button and the Button simultaneously for seconds At this time the current temperature shows the room temperature and the Room Lamp lights on The cooling operation in the Room Mode is operated by the room temperature For the transfer to the Spot Mode press the Cooling Button and the Button simultaneously for 3 seconds again the Room Lamp goes out and the current temperature shows the discharge temperature The initial temperature is set as the Spot Mode operation ROOM SPOT SETTING Room Mode To reduce the temperature of the entire room select Room Cooling E1 High Pressure 2 Low Pressure Spot Mode For targeted cooling of machinery or people etc ES Sensor Error AF Anti Freezing select Spot Cooling Fu Water Full AIRREX HOW TO USE Temperature Control When the operation begins the setting temperature is shown ROOM SPOT SETTING The initial set temperature is 60 F Operation Off Press the temperature control button you can select the desired set temperature The range of temperature control is 34 86 F This is increased or decreased by the unit of Once the desired temperature is set this blinks for 3 seconds ROOMSPOT eee ui the motion is transferred to the set condition Operation On The current temperature is shown 32 99
Download Pdf Manuals