1. 3 embedding platform 6 left wax preservation box Figure 1 equipment overview 2 2 equipment overview see Fig 1 2 3 control panel see Fig 2 3 the equipment use and applicable range 3 1 JK EC1 embedding center has tissue specimens embedding processing function 3 2 JK EC1 embedding center applicable to the hospital pathology diagnosis and laboratory analysis of the pathology of research work 4 Attention 4 1 the use of this equipment must be in accordance with the instruction operation 4 2 be aware of hot wax of embedding center during the operation 4 3 if any mis opeation occur please turn off the equipment and preserve your tissue specimen in the wax box 4 4 non operation person contact this equipment is forbidden equipment installation and operation is processed by technician 4 5 this equipment can not move and tilt during the operation 4 6 working environment temperature range lt 40 C 4 7 operating light on ps heat 2009 01 08 08 08 08 review JUDO Figure 2 control panel Press the heat button the display come to heating as figure 3 below press the back button returns to the main interface back heat heat Press the set button into the equipment Settings interface as shown in figure 4 back temperature switch time Press the temperature key enter set temperature interface as shown in figure 5 temperature 165 C
2. back temperature back A A Wax nozzle v Wax reservoir 65 C v enter Embedding platform 65 C Left wax box 65 C enter Forceps table 60 Right wax box 60 C Press the A button increase the temperature readings press Y button reduce the temperature readings press confirm button the cursor moves After the setting press back button returns to the previous interface According to switch key enter heating interface as shown in figure 6 switch back on Right wax box off Embedding platform Forceps table on The on is started heating the off is stopped heating the return key will return to previous interface According to time key enter time setting interface as shown in figure 7 back time A 12 05 10 vy 10 00 00 enter Press the A button increase readings press V button reduce readings press enter to complete the setting press the back button to return to previous interface Press the time button into the time heating interface as shown in figure 8 back timing A 08 00 Y 16 00 enter Press the A button increase readings press V button reduce readings press enter to complete the setting press the back button to return to previous interface 4 8 routine embedding operation A check the wiring of equipment is correct check the wax in reservoir is enough and go to the next step for o
3. JK EC1 Tissue embedding center USER MANUAL Moss Instruments Co LTD 1 Product overview 1 1 product name paraffin embedding center 1 2 model JK EC1 1 3 product characteristics Embedding center combines automatic constant temperature heating Embedding smooth continuous no block no clouds shut off sensitivity without dripping wax and seepage wax phenomenon Built in lamplight illumination the light is downy bright Can preset the data etc The main technical specification please see table 1 below Table 1 main technical parameters Specification Data value The wax reservoir volume 7680ml Left wax preservation box volume 1680ml Right wax preservation box volume 1680ml Heating temperature range Ambient to 85 C Temperature tolerance EC The pre set time range lh 999h Power consumption lt 800W Equipment dimension long x width X high 600mm X 580mm X 360mm 2 equipment structure 2 1 equipment components and the operation principle This equipment is made up of the wax reservoir wax preservation box embedding platform and electric control system the wax reservoir and wax preservation box are controlled by electric system in a certain temperature range the pedal switch timely control the flow of wax from nozzle for tissue embedding at the embedding platform ce a a 1 4 2 6 1 control panel 4 forceps table 2 wax nozzle 5 right wax preservation box
4. peration B after switch on the equipment the main power switch in on The temperature control of wax reservoir wax preservation box show last time of setting press lighting switch can control embedding a lighting function press embedding platform switch can control embedding temperature C according to the above method to set the temperature of wax resevoir and set the temperature of the wax preservation box press the set button and the related data set flashing press Y and A button to set the data needed to adjust temperature then press the enter button to confirm the setting this time will be covered the last set value and long term preservation the system is in according with this value for temperature control D please use foot switch for tissue embedding E shut down after working shut off the main power switch mark O position there is no display the equipment completely shut down Note when you use the preset function please don t shut down the equipment F Working condition humidity range 30 85 the atmospheric pressure range 860 kPa 1060 kPa electricity power 220 V 10 frequency 50 Hz 5 Attention 1 After receiving the instrument please open the package to examine the outer appearance check the appurtenances and read the instruction carefully before switching on and processing the instrument 2 In order to ensure the security of people and the equipmen
5. place upward Storage This instrument should be stored in the clean and airy indoor place with the relative humidity under 80 and be kept far from the caustic gas 8 Troubleshooting Table 2 simple troubleshooting Trouble Light cannot open Lighting is failed replace it The wax reservoir cannot heat Reset the temperature Equipment cannot switch on Replace the fuse
6. t the three line power source is needed and make sure that the grounding works well Non grounding power is prohibited to this instrument 3 Before the solid paraffin completely melted or before the paraffin dispenser nozzle has warmed and reached the setting temperature DO NOT embed the cassettes by the moment in order to prevent the dispenser nozzle from leaking paraffin and the dispenser pipe blockage 4 The overheat protector has been equipped to this instrument When the detected temperature surpasses the dangerous temperature of 100 C the overheat protector can automatically turn off the power of heating element When the detected temperature drop to 65 C the instrument will automatically activated and rework 5 In order to lengthen the service life of the condenser of Cooling console the successive working time should be within 4 hours And a 10 minutes intermission is needed for restarting the instrument after the power absence 6 The instrument shall be placed in the well ventilated site and away from the hot source 6 Maintenance Service Comply with the condition of following instructed operating regulation we supply a warranty of one year from the sales day To those which have surpassed the warranty period we will also supply maintenance service according to the after sales contract signed by our company 7 Translocation and Storage Translocation Handle in care avoid wetting and