POLIVAC B4/SLT30 2 - Frank`s Hospital Workshop
Contents
1. FRONT PANEL PANNELLO COMANDI _ ef Variability of A vacuum regulation hand control A N Warning see instruction manual Ld gt Pedal switch h Class I Type BF D Earth protection l Switching on O Switching off oN Alternating current MN P B4SLT30 2 IN Sept 2004 pag 3 dipag 3
2. power 3 Emergency if necessary you can obtain quick stop of suction power by disconnecting from the bottle the connector please see A in paragraph Changing over and emptying of the bottles of intermediate tubing CANNULAS OR SUCTION TIPS use always cannulas or suction tips according to ISO 10993 1 Rules PRELIMINARY INSTRUCTIONS please see details on last page Install if supplied the supplementary over fill device as follows A 1 Fix the device on the back side of the central column using the specific screws and connect the black nipple on the device with the white nipple on the column through the intermediate tubing 6x11 length about 15 cm 2 Check the transparent pot should be well screwed and the inside floating must freely work Furthermore you have to a Check that power input corresponds to the technical data label on the back of the unit plug the power cord into the appropriate grounded wall outlet ensuring that the main switch 1 green is in the 0 position switched off b Put the bottles on the unit checking every cap should be well inserted and well pressed and the relative over fill device the floating must freely work Connect the unit to one bottle by using the relative intermediate tubing please see par Changing over and emptying of the bottles Bacteriological filter then connect also the patient tubing c In order to use the pedal switch STOP PN ple
3. POLIVAC B4 SLT30 2 2 bottles Version with piston pump INSTRUCTION MANUAL Edition Sept 2004 This unit is manufactured by ALSA APPARECCHI MEDICALI S R L CASTEL MAGGIORE BOLOGNA ITALY which guarantees its safety reliability and performances only if the installation recalibrations and repairs are performed by personnel authorized by ALSA and if the unit is used in compliance with given instructions in an area that meets all the applicable IEC requirements The Manufacturer will supply on demand the electric diagrams and any further information needed This manual must be kept with the unit Please read this entire manual carefully to become familiar with each of the controls and features before making any attempt to use the equipment clinically and ask for it again if it is missing If any questions arise regarding the information contained in this manual regarding your specific needs please contact the Manufacturer directly or through the local distributor before using the unit VERY IMPORTANT In accordance with the requirements of the European directive for medical devices 93 42 CEE and with the procedures of Company Quality System for the after sale control of the production the users will be pleased to inform the Manufacturer about every however small problem of this unit INDICATIONS AND GUIDELINES FOR POWER SETTINGS According to the international rules EN 10079 1 this equipment is a mobile suction unit with high vacuum hig
4. ase see 2 on the front panel you have to insert in the tubing of the pedal the ring nut O and the gasket N during the transport screwed in the plastic part M and so without activating the pedal you have to insert the tubing and the gasket in the plastic part M screwing tightly the ring nut INSTRUCTIONS FOR USE the unit must be used in vertical position without obstructing the air cooling areas not less of 20 cm from the walls Never switch off the unit at the maximum vacuum first you must reduce the vacuum by the regulator on the front panel or by disconnecting the intermediate tubing see par Changing over and emptying of the bottles 1 Switch on the unit by the main switch 1 2 Select the mode of activation selector 3 as follows Position ON activation without pedal switch Position ON 2 activation by pressing the pedal switch only 3 Set the vacuum power as indicated in the paragraph Suction setting MN P B4SLT30 2 IN Sept 2004 pag 1 dipag 3 SUCTION SETTING To set the desired suction power use the manual control 4 rotary multi turn maximum vacuum clockwise with the relative vacuum gauge 5 and according to the same way but with the patient tubing closed you can preset the maximum vacuum not to be exceeded before using the unit OVERFILL DEVICE Every bottle has a specific overfill device which prevents the aspiration of l
5. ecific side to the vacuum all the group connections tubing is made of silicon rubber sterilizable and so it can be assembled and disassembled very easily by means of a simple pressure During the cleaning the filter can t be wet Anyway if the device works the internal media filter must be dry because otherwise stops completely the suction power When the filter is new working at the maximum vacuum with the patient tubing opened on the vacuum gauge you can see a vacuum of 10 15 cmHg which raises while the media filter is getting obstructed at the same time the suction power decreases The filter must be replaced after about 30 times they can be more or less according to the material aspirated but in any case don t exceed 50 times QUICK CHECKING OF TUBINGS BOTTLES GASKETS AND SO ON To check tubing bottles caps gaskets and so on not damaged or obstructed it is advisable each time you use the unit to switch it on reaching the maximum vacuum with patient tubing closed CLEANING STERILIZATION MAINTENANCE AND TRANSPORT Attention at the moment of sale the accessories even reusable suction accessories on request are not sterile Bottles with caps both unbreakable tubing with connectors gaskets suction accessories are sterilizable by autoclave at 121 C for 20 min or by means cold sterilizer solutions i e Cydex The bacteriological filter is sterilizable by autoclave at 121 C for 20 min but can t be wet when c
6. h flow for hospital and emergency care use for every kind of purpose except breast milk aspiration and low vacuum low flow drainage In detail For operating theatres first aid departments health care facilities starting from setting of 300 mmHg For pharyngeal suction starting from setting of 300 mmHg For O R L suction starting from setting of 400 mmHg For neonatal mucous extraction starting from setting of 100 mmHg For every kind of need in gynaecological field starting from setting of 500 mmHg For extremely delicate suctions starting from setting of 150 mmHg For endoscopic suction starting from setting of 400 mmHg For permanent tracheotomy suction starting from setting of 400 mmHg For plastic surgery starting from setting of 400 mmHg In any case this suction unit must be used under direct control of personnel thoroughly trained in the techniques and problems of medical suction and it is advisable before using the equipment to check carefully its performances for ex aspirating liquids without trusting blindly to previous experiences with other similar units VERY IMPORTANT 1 Use rigid suction tips tube curettes only when the field is under direct visual control otherwise use only soft catheter tubes 2 For suction on delicate tissues use only suction tips with finger vacuum regulation this system grants more safety intermittent suction and if necessary the immediate reduction of suction
7. iquid into the pump without stopping the unit but interrupting the connection between bottle and vacuum pump This overfill device must be in good condition well cleaned and efficient with floating freely working The overfill device on the central column is only for safety s sake CHANGING OVER AND EMPTYING OF THE BOTTLES F TOAPPARATUS B a TUBE 6x11 mm eae gt a ALL APPARECCHO AL TROPPOPIENO BOTTIGLIONE To change over the aspiration between the bottles you must 1 Disconnect from the cap of the first bottle The blue elastic connector side A of the connection intermediate tubing between bottle and unit The connector of patient tubing P 2 Insert them into the same points of the cap on the next bottle To empty the full bottle you have to take it up in a vertical position don t take it on the cap and then start emptying the liquid through the hole for the connection of patient tubing Take away the cap only at the end for the final emptying BACTERIOLOGICAL FILTER WITH FUNCTION OF SUPPLEMENTARY OVERFILL The bacteriological filter able to stop even liquids and usable as a second safety overfill device is a in line filter device reusable and sterilizable 30 times by autoclave at 121 C for 20 min with retantion rating of 99 97 of all particules 0 3 micron The filter must be connected according to detail F and indications on the filter it has a sp
8. leaning The supplementary overfill device if necessary can be sterilized by means cold sterilizer solutions i e Cydex obviously you have to remove it first The unit may be cleaned with mild soap solution but take great care that fluid does not enter the system Wipe dry When the unit is not used keep it in a dry dust free area at room temperature and take care not to spill any liquid onto the system It is advisable to submit the unit for a periodic annual inspection better to the manufacturer Move the equipment around the working area keeping it in vertical position and for shipping or transport Check overfill device Before using the equipment you have to verify the overfill device with the floating freely working and the inside gasket better if changed after a working period of 500 hours well cleaned and in good conditions to perform this control you can unscrew the ring nut floating holder ATTENTION REMEMBER THAT THE ASPIRATION GROUP COULD BE VERY HOT Never operate on the pump please contact trained technical assistance DISPOSAL all the materials including consumer materials must be disposed off according to the different National Rules MN P B4SLT30 2 IN Sept 2004 pag 2 dipag 3 TECHNICAL FEATURES Unit meets Safety Rules CEI EN 60601 1 and CEI EN 10079 1 Classification CEI EN 10079 1 mobile unit for medical suction high vacuum high flow Classification I type BF Input vol
9. tage absorption fuses please see technical data label on the back of the unit Working mode discontinuous max 9h 15 sec max vacuum 15 sec no vacuum Aspiration pump with thermal protection max vacuum 720 mmHg 5 about 0 9 bar 95 kPa Vacuum setting rotary regulator on front panel with vacuum gauge Pedal switch pneumatic water and explosion proof Working noise less than 60 dB Casing protection against liquids common not protected Cooling convention cooling with fan on vacuum pump Dimensions cm 40x34x75 Weight kg 22 Collection container bottle VMLT 3 capacity ml 3000 2 pcs Tubing silicon rubber made patient length m 2 7x12 mm intermediate cm 30 6x11 mm Power cord length mt 3 section 3x1 mm ATMOSPHERIC CONDITIONS of use of transport and storage Temperature C 10 35 Temperature C 40 70 Humidity 30 75 Humidity 10 95 Pressure hPA 700 1060 Pressure hPA 500 1060 STANDARD ACCESSORIES STOP PN pedal switch pneumatic water and explosion proof CONTROLS 1 Main switch 2 Pedal switch socket 3 Working selector with or without pedal switch 4 Vacuum control 5 Vacuum gauge On the back socket with fuses holder for power cord FILTER FILTRO TO PATIENT AL PAZIENTE FILTER FILTRO TO OVERFILL OF THE JAR M N vei j AL TROPPOPIENO DEL BOTTIGLIONE 2 STOP PN PEDAL Siw 4 ma PEDALE STOP PN
Download Pdf Manuals
Related Search
Related Contents
AGENDA SOMMEIL abc - Sommeil et médecine générale 2-CH DIVERSITY DVB-T TUNER MODEL N0: USER MANUAL USER MANUAL 教育の未来と子どもたちの未来のために Vol. 2 SERVER TRAINING MANUAL with washout C2 mode d\`emploi 29 06 2006 American Standard Chandler Americast 7162 User's Manual User Manual - Affordable Scales & Balances Children`s Medical Ventures Catalog Philips 40PFL8664H User's Manual Copyright © All rights reserved.