Home
PC-350
Contents
1. C ComGuard Kronos NET CID350 Server C JbtCID2Serial SOL database only IV Start WEB Server Apply Changes Fig 2 PC 350 modes ComGuard mode This mode set the PC 350 as a standalone monitoring station with user software ComGuard After the confirming of the choice the ComGuard software starts The ComGuard requires an operators name and password Use the following Operator Supervisor Password 123456 The instruction manual for the ComGuard software is save on the hard disk C PC350 doc or you can open it by the icon ComGuard manual on the desktop All the information and data of the ComGuard is stored into the SQL database called ComGuardMain This database is backed up into the folder C Jablotron DBBackup as a ComGuardMainDDMMRR bak file The DDMMRR part in the name of the file is the date of the backup dayday monthmonth yearyear Recommendation Set the backup path to another PC as a path to network drive to keep backup files for case of the PC 350 hardware failure In case of the ComGuardMain database corruption or if the database restore is demanded use an application CGDBtool exe which is placed into the folder C Jablotron CGDBTooN How to restore database Run the CGDBtool exe Click the Use SQL server authentication Fill the passwors as sa Select database to backup restore ComGuardMain Backup restore File Name search the last backed
2. Standard items chapter To keep all the function and application in the good order and to allow remote access set following ports and protocols on the LAN server or firewall e TCP port 3389 and 5300 e UDP port 8080 and 8083 The UDP packets from diallers are sent to the fix IP with port 8080 of a network server firewall or another local Internet connection therefore this IP should be public and accessible by external network A server should resent these packets to the PC 350 s local IP address Starting the PC 350 The PC 350 computer has two users activated Use the following user when working with the PC 350 User IPCMS Password ipcommunication The user Jablotron is activated for a remote access by authorized Jablotron company technician if any change of configuration is demanded Note Do not change user names or user passwords of the PC 350 computer during the time of testing operation 3 month period after the delivery When the PC 350 is started for the first time a user should choose one of the running modes of the PC 350 The icon CMS setup displays possible running mode See the text below for detailed information about the modes Running modes The icon CMS setup displays possible running mode The mode which are not installed are not available on the menu The Apply changes button press starts the chosen running mode see Fig 2 LT x m Select application to be started on the computer
3. MS1 yes MS2 no 987 _ signal 90 GPRS yes MS1 yes MS2 yes 99A ___ signal 100 GPRS no MS1 no MS2 no 991 signal 100 GPRS no MS1 no MS2 yes 992 __ signal 100 GPRS no MS1 yes MS2 no 993 __ signal 100 GPRS no MS1 yes MS2 yes 994 __ signal 100 GPRS yes MS1 no MS2 no 995 __ signal 100 GPRS yes MS1 no MS2 yes 996 __ signal 100 GPRS yes MS1 yes MS2 no 997 __ signal 100 GPRS yes MS1 yes MS2 yes
4. to receive CONTACT ID format e the phone output of the CID350 Modem must be connected to the phone input of the provider s monitoring station directly the CID350 Modem generates ring signal on a telephone line e the CID350 Modem may not be connected to the common telephone line or may not be linked to another telephone line JbtCID2Serail mode When the JbtCID2Serail mode is set the PC 350 behaves as it is monitoring station receiver connected to a PC via COM port The communication protocol for COM port is Surgard or Ademco 685 The parameters of the mode can be set with help of JbtCID2Serial Configurator application open menu Start programs Jablotron JbtCID2Serail JbtCID2Serail Configurator this application allows user to set COM port parameters protocol for communication frequency of heartbeat signal SQL setting and setting for periodic testing interval checking The PC 350 working in mode JbtCID2Serail resend all the received events except periodic tests they are only supervised and in case of missing events from particular accounts the application sends the information about lost connection with the account via COM port SOL database mode The SQL database mode is applicable when a third party monitoring station is equipped by an application which is capable to access the SQL database on the PC 350 remotely and can read the new received data from the database directly The producer of the PC 350 can provide detail
5. PC 350 The PC 350 is a personal computer equipped for central monitoring station CMS use The PC 350 can work as a standalone CMS or as an extension of existing monitoring station to the IP communication The PC 350 is performed for receiving and managing event messages from JA 60GSM JA 60WEB and GC 61 diallers detailed instruction manual for each of the diallers is enclosed to their package The PC 350 receives UDP packets from above mentioned diallers via Internet connection and SMS messages from JA GSM and GC 61 via MS 33 GSM module connected to the serial port The Internet connection is meant as a main communication channel and the SMS is a back up channel Therefore it is necessary to allow an Internet connection with fix IP see the specification in the text below Standard items of the PC 350 PC ASUS Celeron 2 53 Keyboard Mouse MS 33 GSM module MS 33 WaveCom Fastrack M1306B Power supply adaptor for the MS 33 module GSM aerial Serial cable for MS 33 connection PC Information MAC address 00 1E 8C 99 4D 1E GSM module IMFI 354056002925489 PC Name CMSTEST 153 Cabel connecting Connect cables of items according to the Fig 1 See eo See ee LAN Connection GSM module Connection Fig 1 PC 350 back panel Local network connection As the Ethernet adaptor use to marked RJ connector on the Fig 2 showed additional network adaptor MAC address of the adaptor is mentioned above in the
6. RS no MS1 no MS2 yes 952 _ signal 60 GPRS no MS1 yes MS2 no 953 _ signal 60 GPRS no MS1 yes MS2 yes 954 _ signal 60 GPRS yes MS1 no MS2 no 955 _ signal 60 GPRS yes MS1 no MS2 yes 956 __ signal 60 GPRS yes MS1 yes MS2 no 957 _ signal 60 GPRS yes MS1 yes MS2 yes 96A signal 70 GPRS no MS1 no MS2 no 961 signal 70 GPRS no MS1 no MS2 yes 962 _ signal 70 GPRS no MS1 yes MS2 no 963 ___ signal 70 GPRS no MS1 yes MS2 yes 964 __ signal 70 GPRS yes MS1 no MS2 no 965 __ signal 70 GPRS yes MS1 no MS2 yes 966 __ signal 70 GPRS yes MS1 yes MS2 no 967 _ signal 70 GPRS yes MS1 yes MS2 yes 97A __ signal 80 GPRS no MS1 no MS2 no 971 signal 80 GPRS no MS1 no MS2 yes 972 _ signal 80 GPRS no MS1 yes MS2 no 973 signal 80 GPRS no MS1 yes MS2 yes 974 __ signal 80 GPRS yes MS1 no MS2 no 975 _ signal 80 GPRS yes MS1 no MS2 yes 976 __ signal 80 GPRS yes MS1 yes MS2 no 977 _ signal 80 GPRS yes MS1 yes MS2 yes 98A signal 90 GPRS no MS1 no MS2 no 981 _ signal 90 GPRS no MS1 no MS2 yes 982 _ signal 90 GPRS no MS1 yes MS2 no 983 __ signal 90 GPRS no MS1 yes MS2 yes 984 __ signal 90 GPRS yes MS1 no MS2 no 985 __ signal 90 GPRS yes MS1 no MS2 yes 986 _ signal 90 GPRS yes
7. ed information about database structure when demanded Supporting applications GSMDialerCheck The icon GSMDialerCheck on the desktop starts the application The application is used for communication check with JA 60GSM dialers Fill the Device phone number by the telephone number of the SIM card which is in the contacted JA 60GSM dialler Fill the Account ID code by the account ID of the contacted account according to the setting of the JA GSM dialler The content of the SMS message text is sent to the set telephone number via the MS 33 GSM module when the Send button is pressed down We recommend keep the text of the SMS message text as a MO The MO is the key word for asking JA 60GSM dialler status The JA 60GSM dialler answers by an SMS with defined structure The SMS is displayed in the Device answer and the application transform the SMS message into a new Contact ID record in the database with the defined Account ID according to the SMS content As the result of this action is a record in the database the event will be displayed as a new event message from the account Ba CSDiulercnnk Fes Cevics plore w nber 42C ee SMS messes 2 luv favs Accor wtlL zoca 1i an tar or The Appendix A contains a translation table for the sources of the Contact ID format The sources are arranged according to the possible codes sent by the GSMDialerCheck application The complete f
8. gnal is too weak GPRS yes MS1 yes MS2 yes 91A___ signal 20 GPRS no MS1 no MS2 no 911 signal 20 GPRS no MS1 no MS2 yes 912 _ signal 20 GPRS no MS1 yes MS2 no 913 _ signal 20 GPRS no MS1 yes MS2 yes 914 __ signal 20 GPRS yes MS1 no MS2 no 915 __ signal 20 GPRS yes MS1 no MS2 yes 916 __ signal 20 GPRS yes MS1 yes MS2 no 917 _ signal 20 GPRS yes MS1 yes MS2 yes 92A _ signal 30 GPRS no MS1 no MS2 no 921 signal 30 GPRS no MS1 no MS2 yes 922 _ signal 30 GPRS no MS1 yes MS2 no 923 _ signal 30 GPRS no MS1 yes MS2 yes 924 _ signal 30 GPRS yes MS1 no MS2 no 925 __ signal 30 GPRS yes MS1 no MS2 yes 926 __ signal 30 GPRS yes MS1 yes MS2 no 927 _ signal 30 GPRS yes MS1 yes MS2 yes 93A __ signal 40 GPRS no MS1 no MS2 no 931 signal 40 GPRS no MS1 no MS2 yes 932 __ signal 40 GPRS no MS1 yes MS2 no 933 __ signal 40 GPRS no MS1 yes MS2 yes 934 signal 40 GPRS yes MS1 no MS2 no 935 __ signal 40 GPRS yes MS1 no MS2 yes 936 __ signal 40 GPRS yes MS1 yes MS2 no 937 _ signal 40 GPRS yes MS1 yes MS2 yes 94A __ signal 50 GPRS no MS1 no MS2 no 941 signal 50 GPRS no MS1 no MS2 yes 942 _ signal 50 GPRS no MS1 yes MS2 no 943 __ signal 50 GPRS no MS1 yes MS2 yes 944 __ signal 50 GPRS yes MS1 no MS2 no 945 __ signal 50 GPRS yes MS1 no MS2 yes 946 _ signal 50 GPRS yes MS1 yes MS2 no 947 __ signal 50 GPRS yes MS1 yes MS2 yes 95A __ signal 60 GPRS no MS1 no MS2 no 951 signal 60 GP
9. unction of the application is supported by JA 60GSM diallers version FJ61406 and higher Note The application cannot be moved to another computer and the application cannot send SMS abroad A hardware key of the PC 350 protects the starting and setting of the application CMSList The function opens an overview of all the received event messages Messages can be sorted by Account ID or by a date period The function is available only if the Start WEB Server checkbox is on see the CMS Setup window Start the function by the CMSList icon on the desktop the a Internet browser display a login dialog Login as a user jablotron with a password jablotron Then a filter dialog will be displayed set an Account ID and a date period for filtermg messages If the filters are blank all the received messages will be displayed Contact ARC technical support Tel 420 483 559 931 420 559 933 Mobile 420 777 775 031 E mail pco jablotron cz Appendix A Source table for GSMDialerCheck reports Source Translation 999 Communicator received SMS 998 _ Communicator processing SMS 9AA Communicator doesn t respond 9A1 signal is too weak GPRS no MS1 no MS2 yes 9A2___ signal is too weak GPRS no MS1 yes MS2 no 9A3 signal is too weak GPRS no MS1 yes MS2 yes 9A4 signal is too weak GPRS yes MS1 no MS2 no 9A5__ signal is too weak GPRS yes MS1 no MS2 yes 9A6 __ signal is too weak GPRS yes MS1 yes MS2 no 9A7 ___ si
10. up file ComGuard_30_DDMMRR bak Press Restore button AMRWNS Attention If the restore function application is started accidentally and the present database contains later data they will be rewrite by the last performed backup Kronos NET The Kronos NET software is the professional product for security agencies The possibilities of the software are described in its manual When the mode is chosen all the necessary services are started but the application of the software must be started manually the Kronos Terminal or Kronos Config CID350 server mode The PC 350 set into this mode works as an interface between IP or SMS communication and a telephone receiver of an existing monitoring station The PC 350 receives data from JA 60GSM JA 60WEB and GC 61 diallers and stores them into an SQL database The stored data are read by the CID 350Server application The CID 350Server sends the data to the CID350 Modem and this module transform the data into the Contact ID telephone line format The CID350 Modem rings telephone input of the existing monitoring station and send the received data as a classic Contact ID format event The CID350 Modem is connected to the PC 350 via USB cable CID350 mode requirements e CID350 Modem the module is not included as a standard item it must be demanded separately e free telephone input on the provider s telephone monitoring station the provider s monitoring station must be able