Home
        Manual - MagicFX
         Contents
1.   for  example  maintenance and repair  This user manual has been drawn up with the utmost care  MAGIC  FX cannot be held responsible for any mistakes made in this publication or for any consequences  thereof     Page 15    Version 1 0    11  DECLARATION OF CONFORMITY  DECLARATION OF CONFORMITY   according to Annex II 1 A of the Machinery Directive     Concerning the Machinery Directive   We  MAGIC FX B V    Schouwrooij 27   5281 RE Boxtel   The Netherlands    otate under personal responsibility   We are the manufacturer of the product     MFX1150   MAGICFX  CO2 Dominator    to which this statement relates and which is in accordance with the provisions of the following  Directive s        Machinery Directive 2006 42 EC     Low Voltage Directive 2006 95 EC            Directive 2004 108 EG     Pressure Equipment Directive 97 23 EC    The following harmonising standards have been applied       NEN EN ISO 12100    NEN EN IEC 60204 1    Place   Boxtel   Date    18 10 2012  Name  MAGIC FX  Director  B  Veroude    Page 16    User documentation MAGICFX   CO2 Dominator    12  TROUBLESHOOTING             CO2 Dominator is leaking   Check if the coupling of the gas hose is connected properly to the coupling of the CO2 Dominator  If it  is not entirely secured then press it firmly  This is only possible when there is no pressure on the hose   If the problem persists  then consult the technical service of MAGIC FX       Only a small smoke plume is visible when the CO2 gas exits the CO2 Dom
2.  safely   This applies to the use  the circumstances and the regulations as described in this documentation   Reading this documentation and following the instructions are therefore necessary for everyone who is  authorised to work with the CO2 Dominator     The CO2 Dominator must be placed and used in surroundings that preferably               a reasonably stable temperature of between 0 and 30  C      Have    relative humidity degree of no more than 75       Are reasonably free of dust  corrosive gases and high concentrations of organic vapours     Are not situated in the vicinity of a source of vibration     3 2 GENERAL SAFETY RULES      Ensure that children  unauthorised persons and animals cannot obtain access to the CO2  Dominator      Safety devices may not be removed or disabled      All required safety devices must be in good condition and function properly      Ensure sufficient lighting of the surroundings      Keep the workplace clean        Only authorised persons may carry out work with the CO2 Dominator     3 3 WARNINGS    Warning texts have been attached to the CO2 Dominator  With regard to these the following rules  apply       These texts may not be removed or damaged  The operator must regularly check if this is the  case     The operator must ensure that the texts are and remain clearly visible and legible     DANGER WARNING   One must replace texts or signs if these are absent  damaged or  illegible     Sign        explanation    mAG CcrxX  MODEL   MFX115
3.  the direction of      people or objects  Preferably place the        2 cylinders outdoors or in a space  provided with good ventilation and a CO2  detection system  CO2 cylinders are  pressure containers  Therefore secure  them with special gas bottle brackets or  a chain to prevent them from toppling  over        Version 1 0    Connect the other ends of the CO2 high  pressure hoses to the manifold block  and check that these are properly  connected     Now connect the 3 4  CO2 high pressure  hose to the manifold block and check if it  is firmly connected     Connect the other end of the 3 4  CO2  high pressure hose to the socket at the  back of the CO2 Dominator     Again check if it is firmly connected        Page 10    User documentation MAGICFX   CO2 Dominator      Turn on the machine by pushing the  switch of the CO2 Dominator in the    on     positon     After the CO2 Dominator has been fully  connected the CO2 Dominator can be  installed     V            eng       During installation  make sure that you use         free channels      the DMX controller and  that these channels are in the safe mode            LOIS The safe mode means that during the  installation of the CO2 Dominator the 0   values of a channel are set  Consult the  manual of the DMX controller for the set up     Push the    MODE    button to start the set   up of the CO2 Dominator     The display will now change to the  screen pictured on the left     You will see the address behind Safety flash  on a
4. 0  SERIAL NO    00000  AC220 240V  50 60Hz 125W    MADE IN THE NETHERLANDS    operate the CO2 Dominator after reading the   7148    PIC 616 Follow the instructions    The operator must be told that he she may only    A warning is given for this by means of the  command sign of PIC 616  This sign should be  attached to the type sign  See also the photo     627 665404       Page 4    User documentation MAGICFX   CO2 Dominator    Sign and explanation    DN RUP UR  R TSOA a    macicex  MODEL   MFX1150    EN    SERIAL NO    00000 K  PIC 307 High voltage AC220 240V  50 60Hz 125 4                A warning must be given about the machine   s                 THE NETHERLANDS mumm    high voltage by using the caution sign PIC 307  am had  This sign must be attached to the CO2             33 5    Dominator  See also the added photo   18627  665404    Sign        explanation    PIC 323 Low temperatures CAUTION  PIPES ARE EXTREMELY COLD  DO NOT TOUCH  In case of low temperatures a low temperature GLOVES REQUIRED  warning must be issued by means of warning    sign 323     This is attached to the top of the CO2  Dominator        Page 5    4  PARTS    Version 1 0          12 13    Oe        I    Power Switch  Power input  Power output  DMX input  DMX output  Display   DMX LED  MENU button    10   11     Warning LED s  13   14   15     15    UP button  DOWN button  RESET button        2 input    CO2 output  handle    Page 6    User documentation MAGICFX   CO2 Dominator    5  ACCESSOIRES    MFX
5. 1154   Distribution Block MFX3101     Twenty clamp M10    MFX0308     Shuko     powerCON    cable 1 5m    MFX1151     High pressure hose 3 4    MFX1152     High pressure hose 3 4         1153     High pressure hose 3 4    6m 10m 15m    MFX1103     High pressure MFX1106     High pressure MFX1110     High pressure MFX1115     High pressure  hose 3 8   3m hose 3 8   6m hose 3 8   10m hose 3 8   15m    Table 5 1       You can order these parts and accessories from     MAGIC FX B V   Schouwrooij 27  NL 5281 RE BOXTEL  The Netherlands    T   31 0 411 63 50 13        31 0 411 63 50 12  W  http   www magicfx eu  E  info magictx eu       6  PREPARATIONS    Unpack the CO2 Dominator  Dispose of the packaging material without harming the environment   Inspect the machine for any damage  If damage is noticed this must be reported to MAGIC FX     Page 7    Version 1 0    7  INSTALLATION    CAUTION   The machine can be damaged if you do not follow the procedures  carefully     DANGER WARNING   The MAGICFX   CO2 Dominator may only be installed by adults and  authorised persons     DANGER WARNING   MAGIC FX is not liable for working with CO2 gas and CO2 bottles or for  the correct use thereof     Exclusively use approved CO2 bottles  liquid carbon dioxide with dip  pipe  and consult your gas supplier about the installation  instructions   guidelines and regulations for the safe use of the CO2 bottles        For installing the CO2 Dominator work in the following manner     Place the CO2 Domina
6. 2 Dominator out of the safe  mode  the  safety  channel on the CO2  Dominator must be set between 40  and  60        The LED light on the back of the CO2  Dominator now starts to flash on and off     To activate the CO2 Dominator and to    have a CO2 smoke plume blow from the  machine  you press the flash button of  the    fire    channel on the DMX controller     Before starting to blow CO2 always make  sure that nobody is present within the zone  of the CO2 Dominator  Additionally  always  ensure you have a Clear vision of the CO2  Dominator during the effect  For the correct  use of the DMX controller you can consult  the manual of the machine        Page 13    Version 1 0    9  SWITCHING OFF    To switch off the CO2 Dominator  take the following steps     Close the valve of the gas bottle        Activate the     2 Dominator one more     4 time to remove the remaining pressure     from the hose               i    yn    2   T is    E    Only once there is no more gas in the  hose it can be disconnected from the  CO2 Dominator and the manifold block     Disconnect the plug s  of the CO2  Dominator from the energy supply        Page 14    User documentation MAGICFX   CO2 Dominator    10  CE MARKING    PLEASE NOTE    We presume that you  your employees and others who use or come  into contact with the machine are familiar with how the machine must  be dealt with  This includes the correct use  maintenance and repair of  the machine as described in this user manual  This also m
7. INTRODUC TON ntm 3  2 1 DESCRIPTION AND APPLICATION OF THE CO2                                                             3  2 2 NECESSARY ACCESSORIES                                                                         3  3  file 4  3 1 INTRODUCTION                             a E 4  3 2 GENERAL SAFETY B  LES        in eiut edente           incest                 4  3 3 rol lec                                              4  4 PARTS c                                              6  5                           e 7  6 maiz ge lm et 7  7 INSTALLATION                                                                         ca os eia cs Eo eot es oet ia  8  8 USAGE eee eee                                                   13  9 gre tre                                                                                                         14            IVT RUIN Ce 15  11  DECLARATION OF                                                                  16  12  TROUBLESHOOTING        ea               17  SS                                                                       18  14  TECHNICAL SPECIFICATIONS            a            19  15                                                                                                                     19  16  GUARANTEE                                                                                               19             2    User documentation MAGICFX   CO2 Dominator    2  INTRODUCTION  2 1   DESCRIPTION AND APPLICATION OF 
8. Lial  Tr   LP 4 MANUAL       MAGICFX   C02 DOMINATOR    Bassa ca      Hu ode umi ah ete     m Beds rimi te arte  t               VERSION   1 0    PRODUCT CODE   MFX1150 C      DATE   31 10 2012       User documentation MAGICFX   CO2 Dominator    1  FOREWORD  Congratulations  You have bought a great new product from MAGICFX       The MAGIC FX CO2 Dominator is a robust multi head        cannon designed for safely shooting CO2   The CO2 Dominator is equipped with warning LED s to warn people around machine when armed to  start the effect   The CO2 Dominator is also equipped on board DMX512 to control the CO2  Dominator     MAGIC FX is a Dutch manufacturer of professional special effects machines and equipment  We have  been experts in special effects since our establishment in 1995  All our products are made under the  brand name MAGICFX   which by now has acquired a great reputation on account of its quality and  reliability  All products are made in accordance with the European Machinery Directive  MAGIC FX  manages the entire production process in house  from the design stages and prototyping to  production  In short  we cover everything from concept to ready to use products     Moreover  MAGIC FX is Europe s largest supplier of high quality and fireproof confetti products and  streamers  Thanks to our very large stock levels  we can deliver quickly and at low prices     MAGICFX   is used by special effects professionals all over the world and our products are distributed  th
9. THE CO2 DOMINATOR    The CO2 Dominator is intended to electronically blow white  smoke plumes of CO   from a distance  As soon as the        leaves the cylinder through the CO2 Dominator s secured high   pressure hoses  it converts into gas  This formation of gas is  accompanied by a strong hissing sound and a solid white plume  of smoke will be visible  The length of this plume is on average  8 metres  This depends on the air humidity  in case of a high  degree of air humidity  the smoke plume will be larger and in  case of a low degree of air humidity it will be smaller     The CO2 Dominator must be connected to a carbon dioxide         cylinder with dip pipe     Any use other than that described above excludes your supplier  from any liability        The CO2 Dominator has been designed and constructed in such a manner that it can be used safely   This applies to the application  the circumstances and the regulations as described in this  documentation  Reading this documentation and the following instructions are therefore necessary for  everyone who is authorised to work with the CO2 Dominator    2 2 NECESSARY ACCESSORIES    De volgende onderdelen horen bij de CO2 Dominator     MFX0308   Power cable 4x CO2 Cylinders  with dip pipe     High pressure hose 3 4 MFX1154   Distribution block 4x High pressure hose 3 8       Table 2 1    Page 3    Version 1 0    3  SAFETY  3 1 INTRODUCTION    The CO2 Dominator has been designed and constructed in such a manner that it can be used
10. eans that the  employees are familiar with the use of machines through training or    experience     DANGER WARNING   Only use the CO2 Dominator in accordance with the regulations and  instructions in this manual  Consult MAGIC FX in case of doubt        Disclaimers   MAGIC FX B V  excludes liability for unsafe situations  accidents and damage that are the result of       Disregard for the warnings or regulations as set out on the CO2 Dominator or in this  documentation      Use for other purposes or under other circumstances than those set out in this documentation      Alterations to the CO2 Dominator  This also includes the use of replacement parts other than the  Original ones      Insufficient maintenance      Unauthorised removal of safety caps and or safeguards      Incompetent operation of the machine     MAGIC FX B V  is not liable for any consequential loss in the event of a CO2 Dominator breakdown        Copyright 2012    All rights are reserved  Nothing from this manual may be duplicated  or kept in an automated data file   or made public  or in any form or manner  whether electronically  mechanically  by photocopying  by  incorporation  or in any other manner duplicated without the permission of MAGIC FX B V     MAGIC FX at all times retains the right to make alterations without the direct knowledge of the client   The contents of this user manual can also be changed     Please contact the technical department of your supplier for extra information with regard to
11. inator   Visibility can vary due to air humidity  The output will be more visible when there is high absolute air  humidity       There is no white smoke plume visible when the CO2 gas exits the CO2 Dominator    You may not have the right carbon dioxide cylinders  Connect bottles with liquid carbon dioxide and a  dip pipe to the CO2 Dominator    In some cases the dip pipe may be broken  In that case replace the carbon dioxide bottle with another  and inform your gas supplier about the cylinder with the defective dip pipe            output stays open after shooting   Check if there are 4 CO  cylinders connected to the CO2 Distribution Block and if the cylinders are  opened and full  If not  replace or connect the empty or missing        cylinders              CO2 Dominator is still malfunctioning after troubleshooting    Always contact your dealer or the technical service of MAGIC FX first in case of uncertainties   questions about the CO2 Dominator works or other issues with regard to the CO2 Dominator     Page 17    Version 1 0    13  NOTES    Page 18    User documentation MAGICFX   CO2 Dominator    14  TECHNICAL SPECIFICATIONS    Length  350mm  13 8        Measurements   Width  350mm  13 8      and weight Height  150mm  5 9    Weight  18 Kg  39 7lbs      Input  AC 230V 50 60Hz  Power Usage  125W  Fuse  5A 250V 5x20mm    Input  3 pin Neutrik XLR Male Socket  Output  3 pin Neutrik XLR Female Socket  Input  Liquid          Output         Gas   Usage  0 5 Kg s  1 1 165 5  per o
12. nd off  This is the address which can be  used for releasing the machine     Change to the required address by  pushing the A or V button  Then push  the MODE button to confirm your choice           When you use several machines it is  advisable to use the same  Safety  channel  for each CO2 Dominator        Page 11    Upt ions    Saved    Version 1 0    You will see the address behind CO  1  flash on and off  This is the address with  which a series of 5 CO  addresses starts     Change to the required address by  pressing the A or V button  Then press  the MODE button to confirm your choice     The other outputs will automatically be  consecutive  For example  you set  channel 2 as 1   output of the CO2  Dominator         2    output will be channel  3  the 3  output channel 4 etc     Open the valves of the gas bottles        Page 12    User documentation MAGICFX   CO2 Dominator    8  USAGE    TIP   Gives you suggestions and advice regarding easier or more  convenient ways to carry out certain tasks     CAUTION   The machine can be damaged  if you do not follow these procedures  carefully     DANGER WARNING   The MAGICFX   CO2 Dominator may only be installed by adults and  authorised persons     The CO2 Dominator may only be operated if all parts are completely  and correctly installed connected        For using the CO2 Dominator take the following steps     After the set up of the CO2 Dominator  and the correct addresses you are ready  to use the machine       To get the CO
13. rough a dealer network which covers more than 90 countries     Congratulations and enjoy your purchase     This manual describes the MAGICFX amp  CO2 Dominator  The information in this manual is important for  the proper and safe functioning of the CO2 Dominator  If you are not familiar with the installation   operation  preventative maintenance etc  of the CO2 Dominator then please read this user manual  carefully from beginning to end  MAGIC FX also insists that all new users  operators  installers   maintenance workers and cleaners  receive a training course in which this user manual can serve as a  starting point     MAGIC FX advises that the original of this user manual  including appendices  is kept at a safe and  central place  It is best that another original or copy is kept close to the CO2 Dominator at the  workplace     If you are familiar with these matters  then you can use this manual as a work of reference     The following standard markings are used in this manual for drawing attention to certain subjects or  actions     TIP   Gives you suggestions and advice regarding easier or more  convenient ways to carry out certain tasks     PLEASE NOTE   A comment with additional information  alerts you to certain problems     CAUTION   The machine can be damaged if you do not follow the procedures  carefully     DANGER WARNING   You can get  seriously  hurt if you do not carefully carry out the  procedures        Page 1    Version 1 0    CONTENTS  1  FOREWORD PM 1  2  
14. tor on a stable and  even surface    Make sure that there is always a space of 3  metres around the CO2 Dominator which is  free of people     Check if the on off switch is in the    off     position and then connect the power  cable  The CO2 Dominator runs on 230V   50 60Hz     You will need a powerCON plug to  provide the CO2 Dominator with power   The CO2 Dominator is also equipped  with a powerCON    loop cable    connector     By using a powerCON loop cable you  can connect several CO2 Dominators to  the same energy source        Page 8    User documentation MAGICFX   CO2 Dominator    Page 9    Connect a 3 pin DMX cable to the CO2  Dominator     You can connect several CO2  Dominators to each other by using 3 pin  DMX cables     Connect the other end of the DMX cable     male plug  to a professional DMX  controller     4      Always make sure that the controller is    placed in such a way that the operator has a  clear view of all the connected CO2  Dominators           Consult the manual of your DMX controller  for instructions and the safe use of it     Now connect the CO2 high pressure  hoses of 2 metres length to the CO2  cylinders     Turn the couplings firmly by hand           Turning it by hand will suffice  You should  only use a wrench if the coupling continues  to leak     Place the CO2 cylinders  liquid carbon  dioxide with dip pipe  on an even and  solid surface  Place the cylinders in such      a position so that the opening of the    valve does not point in
15. utput  Quick Connector    RU 1  W21 8x1 14       3 8  BSP    DMX                 Design and product specifications can be changed without prior notification     15  MAINTENANCE    To achieve the maximum service life of the CO2 Dominator you must regularly clean the CO2  Dominator and test if it is working correctly   Should the CO2 Dominator not work for some reason then please contact MAGIC FX     DANGER WARNING     Do not replace parts yourself  always consult MAGIC FX if necessary        16  GUARANTEE   A manufacturer s guarantee of 3 years applies to the MAGIC FX CO2 Dominator             guarantee expires if the CO2 Dominator is used for improper purposes and for applications  which are not stated in this manual       The guarantee also expires if the machine is used incorrectly or in violation of the regulations            guarantee expires if the machine is altered without permission from the supplier     Page 19    
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
AVANT LA NUIT DANS LA VILLE KING`S FINGERS  Manual - AstralPool  MANUAL DE INSTRUCCIONES SEGURESTIL 0914 Español folleto  Manuel d`installation & instructions Série DURATECH ®  SB 325 - Bartscher GmbH  4 - MV Agusta Club Schweiz    CHABLAIS LÉMAN DEVELOPPEMENT - Le blog d`Astrid Baud Roche  mechanical adjustment  HP LaserJet 1022 User's Manual    Copyright © All rights reserved. 