Home

EMPower™ Meter Plug-In Card User Manual - ETS

image

Contents

1. Scope and Duration of Warranties Seller warrants to Buyer that the Products to be delivered hereunder will be 1 free from defects in material manufacturing workmanship and title and 2 conform to the Seller s applicable product descriptions and specifications if any contained in or attached to Seller s quotation If no product descriptions or specifications are contained in or attached to the quotation Seller s applicable product descriptions and specifications in effect on the date of shipment shall apply The criteria for all testing shall be Seller s applicable product specifications utilizing factory specified calibration and test procedures and instruments All product warranties except the warranty of title and all remedies for warranty failures are limited to three years Product Warranted Duration of Warranty Period EMPower Meter Plug In Card 3 Years Any product or part furnished to Buyer during the warranty period to correct a warranty failure shall be warranted to the extent of the unexpired term of the warranty applicable to the repaired or replaced product The warranty period shall commence on the date the product is delivered to Buyer however if Seller assembles the product or provides technical direction of such assembly the warranty period for such product shall commence on the date the assembly of the product is complete Notwithstanding the foregoing in the event that the assembly is delayed for a total
2. may use slots 1 through 7 numbered from left to right as you look at the back of the EMCenter 2 Remove the blank panel from the slot by removing the two screws at the top of the blank panel and the two screws at the bottom 3 Carefully insert the EMPower card into the slot of the EMCenter Tighten the four screws 4 Turn on the EMCenter The EMCenter will automatically detect the newly installed EMPower card must wait at least 10 seconds after connecting an EMPower sensor Otherwise this may result in incorrect power sensor detection If this occurs restart the EMCenter to allow re detection of all connected power sensors Note To allow the EMCenter time to accurately auto detect you 5 Connect the EMPower USB RF Power Sensor to the EMPower card using the included USB cable The EMCenter will automatically detect the EMPower sensor when it is connected to one of the four USB slots on the EMPower card 6 Plug the interlock into the connector on the back of the EMCenter The card installation is complete You can control EMPower through the EMCenter touchscreen with ETS Lindgren TILE Totally Integrated Laboratory Environment ETS Lindgren EMQuest Data Acquisition and Analysis Software and other test automation software packages Contact ETS Lindgren for additional information www ets lindgren com 15 This page intentionally left blank 16 www ets lindgren com 5 0 Operation CAUTION Before placing
3. Lindgren for additional information www ets lindgren com EMCenter Modular RF Platform Required The Model 7001 001 EMCenter is required for operation and is sold separately WETS LINDGREN EMCenter Front Panel Back Panel The EMCenter may be controlled from a computer using these software products e ETS Lindgren TILE Totally Integrated Laboratory Environment e ETS Lindgren EMQuest Data Acquisition and Analysis Software e Other test automation software Contact ETS Lindgren for ordering information 8 www ets lindgren com 2 0 Maintenance CAUTION Before performing any maintenance follow the information provided in Safety Information on page v WARNING Maintenance of the EMPower card is limited to external components such as cables or connectors If you have any questions concerning maintenance contact ETS Lindgren Customer Service WARRANTY e v Maintenance of Fiber Optics If Used Fiber optic connectors and cables can be damaged from airborne particles humidity and moisture oils from the human body and debris from the connectors they plug into Always handle connectors and cables with care using the following guidelines CAUTION Before performing any maintenance Q disconnect the fiber optic cables from the unit and turn off power When disconnecting fiber optic cables apply the included dust caps to the ends t
4. MPower sensor connected to port B of the EMPower card in slot 3 W3B FILTER W Device character of EMPower card 3 Board number of EMPower card B Portof the EMPower sensor FILTER Message to EMPower sensor 22 www ets lindgren com Commands Command IDN ID NUMBER POWER BURST NUM FREQUENCY FREQUENCY lt NUM gt Hz FREQUENCY MIN FREQUENCY MAX FILTER FILTER lt NUM gt FILTER AUTO www ets lindgren com Response ETS Lindgren EMPower 7002 001 4 1 3 d d d d d d d d 12 34 dBm 12 34 12 35 dBm NUM Hz 9000 Hz 6000000000 Hz e 1 Note If you receive an error code in response to a command see page 24 for a list of error codes Request device identification Request unique ID number of EMPower card Request measure power level in dBm Request multi measure power level in dBm the number of measurements Is requested in lt NUM gt Request the frequency in Hz Set the frequency in Hz Request the minimal frequency Request the maximum frequency Request filter Set filter to 1 2 3 4 5 6 or 7 Set filter to auto 23 IEEE commands for Interface Clear and Clear are not supported e IEEE status flags in either serial or parallel poll or as a service request are not supported e When IEEE communication is used the first command request should be IDN r Error Codes 24 Warranty www ets lindgren com Appendix A Warranty
5. Model 7002 001 EMPower Meter Plug In Card User Manual SWE IS LINDGREN An ESCO Technologies Company ETS Lindgren Inc reserves the right to make changes to any product described herein in order to improve function design or for any other reason Nothing contained herein shall constitute ETS Lindgren Inc assuming any liability whatsoever arising out of the application or use of any product or circuit described herein ETS Lindgren Inc does not convey any license under its patent rights or the rights of others Copyright 2015 by ETS Lindgren Inc All Rights Reserved No part of this document may be copied by any means without written permission from ETS Lindgren Inc Trademarks used in this document The ETS Lindgren logo is a registered trademark and EMCenter EMPower TILE and EMQuest are trademarks of ETS Lindgren Inc Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and or other countries Revision Record MANUAL EMPOWER CARD Part 399345 Rev A f ome Initial Release March 2015 ii Introduction www ets lindgren com Table of Contents Notes Cautions and Warnings V Safety MTOM AO d RM V 1 4 119 82 7 9 9 oaa 7 EMCenter Modular RF Platform Required 8 AU E
6. Request Power Level cccccccesseeeeceeeeeeeeeaneeeeesaaaees 22 Example 2 Request Filter Setting eese 22 Example 3 Request Filter Setting eese 22 Commands eonan E pO ae nei MAUS 23 1 1 IURI NEU M eH MEE Red E 24 Appendix A Wartanly 5 22 2 eco it eoa o eo Ee eu oso ceca ses 25 Scope and Duration of Warranties 25 Wairtary Excluslolis 6 BUYERS REM COGS 5 cei DE 27 www ets lindgren com Introduction Appendix B EC Declaration of Conformity 29 IV Introduction www ets lindgren com Notes Cautions and Warnings Note Denotes helpful information intended to provide tips for better use of the product Caution Denotes a hazard Failure to follow instructions could result in minor personal injury and or property damage Included text gives proper procedures Warning Denotes a hazard Failure to follow instructions could result in SEVERE personal injury and or property damage Included text gives proper procedures Safety Information v p E Class 1M High Voltage Indicates presence of hazardous voltage Unsafe practice could result in severe personal injury or death Protective Earth Ground Safety Ground Indicates protective e
7. arth terminal You should provide uninterruptible safety earth ground from the main power source to the product input wiring terminals power cord or supplied power cord set Laser Warning Denotes a laser class 1M is part of the operating system of the device www ets lindgren com Introduction This page intentionally left blank vi Introduction www ets lindgren com 1 0 Introduction The ETS Lindgren EMPower Meter Plug In Card is a broadband continuous wave CW diode type power meter The EMPower card for the EMCenter Modular RF Platform can control up to four EMPower sensors simultaneously One EMCenter unit can contain up to eight EMPower cards resulting in a maximum of 32 sensors per EMCenter Note The EMPower USB RF Power Sensor must be ordered separately For ordering information see page 9 please specify model when ordering The EMPower USB RF Power Sensor is optimized for EMC measurements where high dynamic range and fast measurements are required even at low power levels Where most power sensors require long measurement times at low HF levels the EMPower sensor is able to perform accurate power measurements with a measurement speed of 10 ms per sample at power levels as low as 55 dBm EMPower is fully supported by ETS Lindgren TILE Totally Integrated Laboratory Environment ETS Lindgren EMQuest Data Acquisition and Analysis Software and other test automation software packages Contact ETS
8. dgren com Buyer s Remedies If Seller determines that any product fails to meet any warranty during the applicable warranty period Seller shall correct any such failure by either at its option repairing adjusting or replacing without charge to Buyer any defective or nonconforming product or part or parts of the product Seller shall have the option to furnish either new or exchange replacement parts or assemblies Warranty service shall be performed at the Seller s factory or the Buyer s site at the sole discretion of the Seller Within the warranty period the Buyer shall be responsible for all transportation to the Seller s factory and the Seller shall be responsible for transportation of goods to the Buyer s site Within the contiguous 48 United States warranty service performed during the applicable warranty period will be performed without charge to Buyer during Seller s normal business hours After the warranty period service will be performed at Seller s prevailing service rates Subject to the availability of personnel after hours service is available upon request at an additional charge Outside the contiguous 48 United States travel and per diem expenses when required shall be the responsibility of the Buyer or End User whichever is applicable regardless of the warranty period The remedies set forth herein are conditioned upon Buyer promptly notifying Seller within the applicable warranty period of any defect or no
9. e standby light located on the front panel of the EMCenter will flash and then will illuminate steadily 18 www ets lindgren com Note When the EMCenter is in standby mode touch the screen anywhere to reboot 3 Turn the power switch located on the back panel of the EMCenter to the off position 4 Remove the power cord from the power connector on the back panel of the EMCenter 5 Remove the interlock jack from the interlock connector on the back panel of the EMCenter www ets lindgren com 19 This page intentionally left blank 20 www ets lindgren com 6 0 EMPower Command Set See Commands on page 23 for the commands that can be used with the EMPower Meter Plug in Card Each command must include a device ID number as the prefix See the EMCenter Modular RF Platform User Manual for complete information on device ID numbers Note Terminate each command with a carriage return CR EMCenter eee GL W2B IDN EMPower Sensors EMPower Module i W2C IDN W2D TIDN www ets lindgren com 21 Examples EXAMPLE 1 REQUEST POWER LEVEL To request the power level of the EMPower sensor connected to port A of the EMPower card in slot 2 W2A POWER EXAMPLE 2 REQUEST FILTER SETTING To request the filter setting of the EMPower sensor connected to port B of the EMPower card in slot 2 W2B FILTER EXAMPLE 3 REQUEST FILTER SETTING To request the filter setting of the E
10. ice representative you spoke with and the nature of the conversation Include the serial number of the item being returned 3 Package the system or component carefully If possible use the original packing materials or carrying case to return a system or system component to ETS Lindgren www ets lindgren com 11 This page intentionally left blank 12 www ets lindgren com 3 0 Specifications Note For complete EMPower USB RF Power Sensor specifications see the EMPower USB RF Power Sensor User Manual Mechanical Specifications Data Connector e Sensor side USB type B e Card side USB type A Environmental Specifications Temperature Range e Operating 0 C to 40 C 32 F to 104 F e Storage 20 C to 85 C 4 F to 185 F Relative Humidity 10 to 90 non condensing Supply Specifications Supply Voltage Through EMCenter Power Consumption mW Less than 200 mW Interface Specifications www ets lindgren com 13 This page intentionally left blank 14 www ets lindgren com 4 0 EMPower Plug In Card Installation CAUTION Before connecting any components follow the information provided in Safety Information on page v CAUTION The EMPower card is designed to be used ONLY with the EMCenter Do not use the card in combination with any other system Determine in which empty slot in the EMCenter Modular RF Platform you want to install the EMPower Meter Plug in Card You
11. into operation follow the information provided in Safety Information on page v CAUTION Prior to operation verify that the mains voltage is within the operating range of the equipment Powering On and Off EMCenter Note For information on using the EMCenter touchscreen see the EMCenter Modular RF Platform User Manual oO POWER ON Note Verify all cards are installed correctly in the EMCenter Plug the power cord from the mains inlet on the back panel of the EMCenter Modular RF Platform into a power outlet Plug the interlock jack into the interlock connector on the back panel of the EMCenter eo N gt O Turn the power switch located on the back panel of the EMCenter to the on position www ets lindgren com 17 4 Touch anywhere on the EMCenter screen It will take approximately 20 seconds to boot The Information screen will flash and then the Home screen will display itch 7001 001 NC NC cMSWICITTOO1 021 EMSense 7007 001 No probe EMControl 7006 001 358 9 100 0 cm sense 7007 002 Standby Press to start 30 000 000 MHz RF OFF Sample EMCenter Home Screen POWER OFF 1 Press the Off button located on the EMCenter screen EMPower 7002 001 ss he d EMSwitch 7001 001 NC NC EMSwitch 7001 021 Switch off system EMSense 7007 001 Ea EMControl 7006 00 EMSense 7007 002 Standby Press to start 30 000 000 MHz RF OFF 2 Press OK to switch off the system Th
12. n conformance and making the product available for correction www ets lindgren com Warranty 27 The preceding paragraphs set forth Buyer s exclusive remedies and Seller s sole liability for claims based on failure of the products to meet any warranty whether the claim is in contract warranty tort including negligence and strict liability or otherwise and however instituted and upon the expiration of the applicable warranty period all such liability shall terminate INNO EVENT SHALL SELLER BE LIABLE TO BUYER FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND ARISING OUT OF OR AS A RESULT OF THE SALE DELIVERY NON DELIVERY SERVICING ASSEMBLING USE OR LOSS OF USE OF THE PRODUCTS OR ANY PART THEREOF OR FOR ANY CHARGES OR EXPENSES OF ANY NATURE INCURRED WITHOUT SELLER S WRITTEN CONSENT DESPITE ANY NEGLIGENCE ON BEHALF OF THE SELLER IN NO EVENT SHALL SELLER S LIABILITIES UNDER ANY CLAIM MADE BY BUYER EXCEED THE PURCHASE PRICE OF THE PRODUCT IN RESPECT OF WHICH DAMAGES ARE CLAIMED This agreement shall be construed in accordance with laws of the State of Texas In the event that any provision hereof shall violate any applicable statute ordinance or rule of law such provision shall be ineffective to the extent of such violation without invalidating any other provision hereof Any controversy or claim arising out of or relating to the sale delivery non delivery servicing assembling use or loss of
13. ns which results in whole or in part from 1 negligent storage or handling of the product by Buyer its employees agents or contractors 2 failure of Buyer to prepare the site or provide an operating environmental condition in compliance with any applicable instructions or recommendations of Seller 3 absence of any product component or accessory recommended by Seller but omitted at Buyer s direction 4 any design specification or instruction furnished by Buyer its employees agents or contractors 5 any alteration of the product by persons other than Seller 6 combining Seller s product with any product furnished by others 7 combining incompatible products of Seller 8 interference with the radio frequency fields due to conditions or causes outside the product as furnished by Seller 9 improper or extraordinary use of the product or failure to comply with any applicable instructions or recommendations of Seller including maintenance calibration and cleaning procedures and intervals or 10 acts of God acts of civil or military authority fires floods strikes or other labor disturbances war riot or any other causes beyond the reasonable control of Seller This warranty does not include 1 batteries 2 cables 3 gasket 4 fingerstock or any item that is designed to be consumable Seller does not warranty products of others which are not included in Seller s published price lists 26 Warranty www ets lin
14. o maintain their integrity Before connecting fiber optic cables clean the connector tips and in line connectors Before attaching in line connectors clean them with moisture free compressed air Failure to perform these tasks may result in damage to the fiber optic connectors or cables www ets lindgren com Replacement and Optional Parts Note ETS Lindgren may substitute a similar part or new part number with the same functionality for another part part number Contact ETS Lindgren for questions about part numbers and ordering parts Following are the part numbers for ordering replacement or optional parts for the EMPower Meter Plug In Card Part Description Part Number EMPower USB RF e 7002 002 EMPower 6 GHz RF Powerhead Power Sensor USB e 7002 003 EMPower 6 GHz Burst Pulse Powerhead USB e 7002 004 EMPower 18 GHz RF Powerhead USB e 7002 005 EMPower 18 GHz Burst Pulse Powerhead USB 10 www ets lindgren com Service Procedures CONTACTING ETS LINDGREN Note Please see www ets lindgren com for a list of ETS Lindgren offices including phone and email contact information SENDING A COMPONENT FOR SERVICE 1 Contact ETS Lindgren Customer Service to obtain a Service Request Order SRO 2 Briefly describe the problem in writing Give details regarding the observed symptom s or error codes and whether the problem is constant or intermittent in nature Please include the date s the serv
15. of thirty 30 days or more from the date of delivery for any reason or reasons for which Seller is not responsible the warranty period for such product may at Seller s options commence on the thirtieth 30th day from the date such product is delivered to Buyer Buyer shall promptly inspect all products upon delivery No claims for shortages will be allowed unless shortages are reported to Seller in writing within ten 10 days after delivery No other claims against Seller will be allowed unless asserted in writing within thirty 30 days after delivery or assembly if the products are to be assembled by Seller or in the case of alleged breach of warranty within the applicable warranty period www ets lindgren com Warranty 25 Warranty Exclusions Except as set forth in any applicable patent indemnity the foregoing warranties are exclusive and in lieu of all other warranties whether written oral express implied or statutory EXCEPT AS EXPRESSLY STATED ABOVE SELLER MAKES NO WARRANTY EXPRESS OR IMPLIED BY STATUTE OR OTHERWISE WHETHER OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE OR USE OR OTHERWISE ON THE PRODUCTS OR ON ANY PARTS OR LABOR FURNISHED DURING THE SALE DELIVERY OR SERVICING OF THE PRODUCTS THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF Warranty coverage does not include any defect or performance deficiency including failure to conform to product descriptions or specificatio
16. tre 9 Maintenance of Fiber Optics If USE 4 4 9 Replacement and Optional Parts 10 Service Procedures x sic Sa E eee 11 Contacting ETS LIndgreri sioe e ha Ete ie certe 11 Sending a Component for 11 5 11 5161 16 1115 1 19111 058 13 Mecharnical SpeelliCaltilorg sse id dated xd Ei e boue EC dole se PP HR UE 13 Environmental Specifications cccsssseeseseeeeeeeeeeeeeeeeaaeeeseeeeeeeeeeeeeeeeeeaas 19 Supply Specie allOls 2 e eet oi a eti e tete ee t Ho i 13 10 101 19 2 2 15 1116 1119 25507 5 1 13 4 0 EMPower Plug In Card Installation 15 291106 16 19 dees 17 Powering On and Off EMCenter scccccceeeeeeeeeeeeessseeeeeeeeeeeeeeeeeaas 17 POWER OM m 17 o ze p 18 6 0 EMPower Command Set cess 21 EXaITIDIGS asian Sobiamutiac Moi 22 Example 1
17. use of the products or any part thereof or for any charges or expenses in connection therewith shall be settled in Austin Texas by arbitration in accordance with the Rules of the American Arbitration Association and judgment upon the award rendered by the Arbitrator may be entered in either the Federal District Court for the Western District of Texas or the State District Court in Austin Texas all of the parties hereto consenting to personal jurisdiction of the venue of such court and hereby waive the right to demand a jury trial under any of these actions 28 Warranty www ets lindgren com Appendix B EC Declaration of Conformity ETS Lindgren Inc declares these products to be in conformity with the following standards following the provisions of EMC Directive 2004 108 EC EMPower Meter Plug In Card Emission EN 61326 1 2006 Class B Electrical equipment for measurement control and laboratory use Immunity EN 61326 1 2006 Industrial level performance criteria A Electrical equipment for measurement control and laboratory use Technical Construction Files are available upon request www ets lindgren com EC Declaration of Conformity 29