Home

T-336Cx/Nx/NDx User Manual

image

Contents

1. Exp1 Exp2 LL TX Level R Protocol type 10dBm lt Auto MNP V42 lt 1 Use P or keys to shift among fields then press ENTER key to confirm and wait for lt appears on the LCD screen 2 Press EXIT key to quit from this menu 18 CHAPTER 3 FRONT PANEL AND MENU TREE 3 4 The Menu Tree Main Menu STATUS DIAL T PROTOCOL Version Top f TEST CONFIG MODEM Et CONFIG DTE COMMAND LINE SETUP _ PROFILE lt a REMOTE STATUS A STATUS MENU REMOTE STATUS MENU Tx Level XX dBm Rx Level XX dBm S N Ratio XX dB EQM Valueio XXX F Shift X X Hz F F Shift X X Hz Delay XXXX ms P jitter X Deg STATUS F Echo XX X dB DTE XXXXX ASY 10 Retrains XXXXX RX Speed XXXX TX Speed XXXX RX Baud XXXX TX Baud XXXX RX Freq XXXX Hz TX Freq XXXX Hz TX PowerOff X dB Menu Retrain Interface indicators TR MR RS CS CD T Note The function with asterisk mark is only available for V 32 and above The function with both and marks is only available for V 34 19 CHAPTER 3 FRONT PANEL AND MENU TREE B DIAL MENU Dial a Number Edit a Number Ring Times Progress Tone Redial Delay Dial Type SPK Control dial Off SPK Volume C PROTOCOL MENU Protocol Type Discon Method Login Check Send Password CallBack No CallBack
2. Issue a retrain or rate change in normal line condition Issue a retrain or rate change in poor line condition Issue a retrain or rate change in worse line condition product designer use only Auto speed fallback and fall forward Enable Dial Line Default Disable Leased Line Default Enable the modem to monitor and control the remote modem through the secondary channel enable remote access function disable remote access function default Select the dynamic range of receiving signal 12 to 44 dBm Default 2 to 35 dBm CHAPTER 3 FRONT PANEL AND MENU TREE 3 5 6 CONFIG DTE MENU Item Name Command Description This setting is used to determine DTE speed when auto DTE eae f Pepo at speed conversion is ON in V 42 MNP normal mode 300 bps 600 bps When using direct mode and all the synchronous modes this setting will not available and DTE speed 1200 bps will be determined by modem speed DTE speed 1800 bps modem speed 2400 bps The throughput is improved by using data 3600 bps compression enhance this set higher than the modem 4800 bps speed is suggested to enable more effective operation 7200 bps When use AT command and auto baud rate detect 9600 bps function ON this setting will be replaced by identified speed 12000 bps 14400 bps The Auto baud rate function can detect all the listed 16800 bps DTE speed 19200 bps 21600 bps Default 57600 bps 24000 bps 26400 bps 2
3. If it is 4 wires leased line the pin 4 5 is TX pin 3 6 is RX When you connect two modems in back to back style don t forget to interchange TX and RX lines A TX gt B RX A RX gt B TX ON LI OFT DIE PHONE LEASED DIAL rs ee RJ11 TX 2W Leased TX 2W Back up Line Line RX If use dial back up RX RJ45 modular feature telephone cable BOX or RX BLK Leased TX 2W RED Line TN GRN RX YEW BOX Figure 2 2 Leased Line connecting diagram 13 CHAPTER 3 FRONT PANEL AND MENU TREE 3 1 3 2 3 3 3 4 3 5 CHAPTER3 FRONT PANEL AND MENU TREE The Front Panel Description The Rear Panel Description Operating the TAINET Network Series Modem The Menu Tree Detailed Description of the Menu Tree CHAPTER 3 FRONT PANEL AND MENU TREE CHAPTER 3 FRONT PANEL AND MENU TREE 3 1 The Front Panel Description There are 5 key on the front panel of TAINET s Modem VO DA Key Right Key Left Key ENTER Key and EXIT Key one 2 x 16 LCD displayer and 10 LEDs Through these interfaces users are able to see the status of modem or chang the configurations as illustrated below it EXIT VO DA E E um bo 4 ENTER DP sth E Figure 3 1 TAINET T 336Cx Front Panel 3 2 The Rear Panel Description The rear panel of TAINET T 336Cx modem contains an IEC 320 AC Power Inlet Connector a Power On Off switch a RS 232 connector for connecting to D
4. LAPM reliable LAPM reliable with fallback to normal mode LAPM reliable with fallback to MNP mode MNP reliable with fallback to normal mode AT An async tolerance 0 basic ASI 1 to 2 5 1 extended ASI 2 3 to 2 5 50 CHAPTER 5 INSTRUCTION SETS Cmd Function Description AT Bn modem speed V 34 Adaptive V21_300 FAX 300 B103_ 300 V22 1200 B212 1200 V22 2400 V23_1200 V26b_1200 V26b_ 2400 V27_2400 V27_4800 V29_7200 V29_ 9600 V32_4800 V32b_7200 V32_9600T V32_9600Q V32b_ 12000 V32b_ 14000 V34_ 19200 V34_ 24000 V34_28800 V32t_16800 V32t_19200 V34_ 4800 V34_7200 V34_ 9600 V34_ 14400 V34_ 16800 V34_ 21600 V34_ 26400 V34_ 12000 V34_2400 V34_ 31200 V34_ 33600 V17_7200 V17_9600 V17_12000 V17_ 14400 V32b_ Adaptive AT Cn data compression on off 0 data compression off 1 data compression on 51 0 Jl UNO CHAPTER 5 INSTRUCTION SETS AT Dn DTR off to on actions 0 DTR off to on normal 108 2 1 DTR off to on dial ans according to ring in 108 1 AT En auto retrain control 0 auto retrain disable 1 auto retrain enable AT Sn display current line status 0 display local status 1 display remote status AT Gn auto fall forward fallback enable 0 auto fall forward fallback disable 1 auto fall forward fall back enable autobauding on off 0 autobauding off 1 autobauding on calling
5. There comes up the problem of interference In V 21 V 22 V 22bis operating modes the T 336Cx used the frequency split method Whereas in V 32 V32bis V 34 mode it must provides echo cancellation because originate and answer modems occupy the same frequency band 4W leased line offers two independently unilateral transmission channel therefore it can achieve full duplex communication with less interference Obviously the line quality of 4W leased line is better than that of 2W leased line However the T 336Cx does an excellent job with both 2W and 4W leased lines and even dial line MODEM _ __ MODEM 2W Leased Line MODEM A MODEM 4W Leased Line FIG 4 3 2W 4W leased line 4 4 Answer Mode VS Originate Mode While using the dial line there must be a modem initiating the call once the exchange recognizes the number it connects the circuit to the answering modem with ring signals Answering modem can pick up the call manually or automatically Afterward it issues the answer tone to connect with the originate modem Usually we call the modem which dials the call as originate mode and the other one as answer mode According to the role of the connection the training sequence and working frequency band of either modem is different from each other even operating with leased line With 2 4 wire full duplex operation such as V 21 V 22 V 22bis V 23 V 32 V 32bis V 34 Bell 103 and Bell 212A there should be an originat
6. 5 INSTRUCTION SE Su a 47 5 1 AT Comm nd Seta ts 47 5 22 Dia Modifiers ean n e USA MANE AAA RTA A E ees SUA AAA 53 So R s lt Ga Ya IAA aa a a aaa a N a a ais 54 5 4 V 25bis A to call A n a caia 56 CHAPTER 6 MAINTENANCE daa Aaa icc is 58 A ASA PS SA E E AAA DA 58 6 24 OS TUE AI E MAA OWEN KAM IAA WAA MAUWA ALADE MAONI ABU SOLA 58 6 3 Periodic Maintenance in A AA 58 6 4 Troubleshooting a Rails 58 6 5 Return Procedu A A ia e Kia KAA 58 APPENDIX 1 T 336Cx S REGISTER TABLE 0 ccccccccccsscccssscccssscecssssecssssecssssecsseeeesaes 59 APPENDIX 2 T 336Cx LCD MENU QUICK REFERENCE ooooccccccconcconcconnnonnnconncconoconanos 67 APPENDIX 3 T 336Nx LCD MENU QUICK REFERENCE coooococccconcconcconnconnnconnconnconnnoos 68 INFORMATION TO THE USER NOTE This equipment has been tested and found to comply with the limits for a Class A digital device Pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and if not installed and used in accordance with the instructions may cause harmful interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on The user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate
7. 5 6 CONFIG DTE MENO raras waa aia 30 3 5 7 COMMAND MENU solia 32 3 5 8 EINE SETUP MENU iia 33 3 5 9 PROFILE MENU a ad ia es oleo 34 CHAPTER 4 GENERAL INFORMATION AND FEATURES 4 ece 38 O A ai kaka kiki 38 4 2 Dial Line VS Leased Line O a anwani 38 4 3 2W 4W Leased Ki is 39 4 4 Answer Mode VS Originate MOde ooooooconioccconococnnonnnoonncconocona nono ccon caco nocancconnanns 39 4 5 Synchronous VS Asynchronous ccccccccescceseceesceececaeceeeeeeeesseecaecneeneeeenseees 40 4 6 Error Correction And Data Compression ccccccccssecsseceseceeseeeseeeeaeeneeeaeeeaeens 40 4 7 Configuration Profile Set Up sici n id ii 41 4S Remote AUS cave edn ee wee eae ieee 41 4 9 Multi standard Hana AA AN 41 4 10 Auto Dial Bare dl laca dead 42 4 11 Auto Fallback And Fall Forward wwwwwwwmwmmenimam nm nwmmmanm wima 42 4 12 Line Status MA bs E 42 413 BER Tetuan tar ted 43 E Mt Seti LIAL A A A A 43 4 15 Front Panel Lock and Password ProteCt ooooccninccinocinocaconoconnnonononnnccnnonancconncnns 43 4 16 ITU T V 13 V 23 Simulated Carrier Control in Half Duplez lt c 44 4 17 PASSWORD AND CALLBACK FUNCTIONS ocoocccccnoonconnoonconnonononncnonconocnnos 44 4 17 1 Dynamic Password CallBack oonooonnccnncccnococonaconnnonnnconccconoconnnnnnnoo 44 4 17 2 Extension Code for Stored Phone Numbers 4 17 3 Additional Informat Onto rr 44 4 18 Intelligent Diao Ma dial 45 CHAPTER
8. AT amp K3 RTS CTS flow control Unit Function Description bit 3 2 DTE DCE speed convert 00 AT JO enable DTE DCE speed convert 01 AT J1 disable DTE DCE speed convert 10 reserved 11 reserved bit 7 6 5 4 auto dial telephone number dec AT B Desired Highest DCE Speed 0 adaptive baud rate 1 V21 300 2 B103_ 300 3 V22 1200 4 B212A 1200 5 V22b_2400 6 reserved 7 V23_1200 1200Tx 75Rx 8 V26b_1200 V26b_1200 9 V26b_2400 V26b_ 2400 APPENDIX 1 T 336Cx S REGISTER TABLE 10 reserved 11 reserved 13 reserved 14 reserved 15 V32 4800 16 V32b 7200 TCM 17 V32_ 9600 TCM 18 V32_ 9600 QAM 19 V32b_12000T 20 V32b_14400T 26 V34 19200 27 V34 24000 28 V34 28800 29 reserved 30 reserved 31 V34 4800 32 V34 7200 33 V34 9600 34 V34 14400 35 V34_ 16800 36 V34 21600 37 V34 26400 38 V34_ 12000 40 V34 2400 41 V34 31200 42 V34 33600 43 reserved 44 reserved 45 reserved 46 reserved 47 V32b_Adaptive S53 00010011 binary Bit Mapped Options bit 3 2 1 0 protocol type 0000 ATANO normal mode 0010 AT N2 MNP reliable mode 0011 AT N3 auto reliable mode 0100 ATN4 LAPM reliable No Default Unit Function Description 0101 AT N5 LAPM reliable with fallback to normal mode 0110 AT N6 LAPM reliable with fallback to MNP mode 0111 AT N7 MNP reliable with fallback to normal mode bit4 0 AT CO data compression
9. Char 21 Answer Mode Originate Mode On Off Internal External Loopback High Medium Low 1 2 5 1 2 3 2 5 US 39 UK 33 3 Force a off hook activity using Enter key On Off Off On 0 dBm 31 dBm 0 dBm 15 dBm On Off 12 44dBm 2 35dBm 115200 bps 76800 bps 57600 bps 38400bps 33600 bps 31200bps 32000bps 28800 bps 26400 bps 24000 bps 21600 bps 19200 bps 16800 bps 14400 bps 12000 bps 9600 bps 7200bps 4800 bps 3600 bps 2400 bps 1800 bps 1200 bps 600 bps 300 bps Off X On X Off RTS CTS CTS only Force On Command Mode Disconnect Modem Reset 108 2 108 1 Force On Normal Normal Force On Force On Normal V 13 HDX V 23 HDX ASYNC SYNC 8 9 10 11 Off On Off On AT Command V 25bis Command Dumb Mode Off On ASYNC HDLC SDLC BSC 7 O 1 7 E 1 7 N 2 8 N 1 Idle Sync CHAPTER 3 FRONT PANEL AND MENU TREE H LINE SETUP MENU Line Type Leased To Dial Backup Tel Backup Speed Dial To Leased Dial 2W Leased Line W4W Leased Line Manual Auto No Dial Backup 0nnnn 1nnnn 9nnnn V34 Adaptive V34 336 V34 312 V34 288 V34 264 V34 240 V34 216 V34 192 V34 168 V34 144 V34 120 V34 96 V34 72 V34 48 V34 24 V32b Adaptive V32b 144 V32b 120 V32 96Q V32 96T V32b 72 V32 48 V26b 2400 V26b 1200 V23 1200 V22b 2400 V22 1200 BELL 212A BELL 103 V21 300 Manul Auto Dial To Leased Timer Forver 0 255 Minutes Dial to Dail I PR
10. Leased Line There are two kinds of telephone lines dial lines and leased lines described as below A Leased line provides users a dedicated communication channel Both ends of the circuit are permanent It offers continuous service and provides absolute security It will not be invaded by any other circuit due to the dedication 1t supports better quality and higher reliability DTE MODEM 7 MODEM DTE FIG 4 1 Leased Line B B Before using a dial line such as the circuits for telephone and facsimile machine we have to dial a number For the users who are used to communicate with different counterparts such as bulletin board system BBS public service network and toll free services this will be a better choice Due to the time consuming dialing procedure 45 60 Sec the efficiency is lower than that of leased lines It is even worse when line or destination is busy Furthermore the communication path is different at each dial so the line quality is not ensured Besides it doesn t guarantee good security To make this modem operate in 2 4 wire leased line or dial line you need to do some settings with Line Type Selection under LINE SETUP menu FIG 4 2 Dial Line 38 CHAPTER 4 GENERAL INFORMATION AND FEATURES 4 3 2W 4W Leased Line We had talked modem operate in the previous section There are two wire leased lined and four wire leased line 2W leased line achieves full duplex with only a pair of lines
11. R lt a L The factory setting is REEE and can be modified by users Before you change the password you need to enter the old one So don t forget the password you had entered 43 CHAPTER 4 GENERAL INFORMATION AND FEATURES 4 16 ITU T V 13 V 23 Simulated Carrier Control in Half Duplex The modem normally operates in full duplex mode However some applications may requires control of a remote DCD signal by a local RTS signal V 13 V 23 operation allows local RTS control of remote DCD signal without on off carrier switching in half duplex operation The V 13 V 23 function apply to the SNA network and the related setting is located in DCD control under CONFIG DTE menu 4 17 PASSWORD AND CALLBACK FUNCTIONS 4 17 1 Dynamic Password CallBack Special Control codes below can be utilized to assign Dynamic Login Password or Call Back Phone Number work with both AT command dialing string and front panel dialing operation a lt lt string gt Control code for Dynamic Password assignment lt string gt after lt lt will be sent to ANS modem as Password It overrides the setting in Send Password but will be ignored if Send Password Off b gt lt string gt Control code for Dynamic Call Back Number assignment lt string gt after gt will be sent to ANS modem as the desired Dial Back Number After ANS modem authenticated ORG modem it will call back with lt string gt T
12. RJ 11 6 pins jack one is DIAL LINE and the other is PHONE Connect the PHONE jack to telephone set and then connect the telephone line to DIAL LINE jack The pin layout of the PHONE connector for RJ11 operation is as follows Pin Color PHONE pin defined 1 No Connect No Connect 2 Black Not used 3 Red Tip 4 Green Ring 5 Yellow Not used 6 No Connect No Connect The pin layout of the DIAL connector for RJ11 operation is as follows Pin Color Dial Line pin defined 1 No Connect No Connect 2 Black Not used 3 Red Tip 4 Green Ring 5 Yellow Not used 6 No Connect No Connect PHONE LEASED DIAL AAA E ME RJ11 modular telephone cable RED GRN BOX Figure 2 1 Dial Line connecting diagram 12 CHAPTER 2 INSTALLATION 2 7 Connecting With Leased Line For the leased line connection you should connect the lines RJ45 connector labeled with Leased on the back of Modem Modem Pin No Color 2 Wire 4 Wire 1 Blue TX RX TX al 2 Orange TX RX TX Leased 3 Black RX Ling 4 Red TX RX x gt 5 Green TX RX TX 6 Y ellow RX 7 Brown RX all 8 White or Gray RX When it used RJ 45 8 core wire pin 1 2 is a group used for 2 wires leased line application it is TX for 4 wires leased line application Pin 7 8 is another group it is no used in 2 wire leased line application it is RX for 4 wires leased line application When it used RJ 11 4 core wire pin 4 5 is TX RX for 2 wire leased line application
13. S1 AT amp SO AT amp Cn AT8C0 AT amp Cl AT amp C2 AT amp C2 AT amp Rn AT amp RO AT amp RI AT amp Mn AT amp MO AT amp MI1 ATS19 n bit5 4 ATS23 n bit2 ATS23 n bit Disconnect Normally used with 108 1 Force Modem reset DSR signal control selection DSR ON after Modem handshaking Force DSR in ON position DCD signal control selection Force DCD in ON position DCD ON means line is in connection while DCD OFF means line is OFF default ITU T V 13 standard simulated carrier in half duplex mode ITU T V 23 standard simulated carrier in half duplex mode RTS signal control selection Controlled by RTS Keep RTS in ON position Data format selection in data mode Async Sync Total bit length for async data format including Start Stop Parity Data bits default 10 DTE control AL through EIA RS 232 pin18 Enable Disable default DTE control RDL through EIA RS 232 pin21 Enable Disable default CHAPTER 3 FRONT PANEL AND MENU TREE 3 5 7 COMMAND MENU Item Name Command Command Mode ATSI9n AT command bit1 0 V 25bis command Dumb mode Auto Baud AT Un On AT U1 Off AT U0 Framing ATS19 n ASYNC bit 1 0 HDLC SDLC BSC Async form ATS19 n bit5 4 7 O 1 7 E 1 7 N 2 8 N 1 Idle char ATS19 n bit3 Idle SYNC 32 Description Intelligent function command set selection Hayes compatible AT command set with async format ITU
14. addition to 100 error free it also provides two to four times data compression rate to increase throughput MNP class 4 provides error corrections MNP class 5 provides data compression for up to two times On the other hand V 42 and V 42bis are the recommendations from ITU T V 42 to provide error correction and V 42bis provides data compression for up to four times Due to the improved throughput the T 336Cx provides DTE speed up to 115200 bps for between data terminal and modem During connecting the modem automatically recognizes the protocol being used by the remote modem and set the priority order as LAPM with EC gt LAPM gt MNP 5 gt MNP 4 gt NORMAL Under these error correction and data compression operations there should be some kinds of flow control between modem and data terminal equipment DTE to avoid data loss the hardware solution to the modem is by controlling RTS and CTS signals The software solution is by utilizing X on and X off codes To find the setting information dealing with error correction and data compression you may look up the PROTOCOL menu In addition CONFIG DTE menu gives you the guide to flow control setting 40 CHAPTER 4 GENERAL INFORMATION AND FEATURES 4 7 Configuration Profile Set Up The TAINET Network Series Modem have various operating modes To save your energy it provides 10 sets of factory default settings as well as 10 sets of user setup profile which store data
15. off AT C1 data compression on bit 7 6 5 reserved S54 Bit Mapped Options bit 3 2 1 0 Call back telephone number 0000 1001 0 49 1010 1111 Off Bit 3 0 Call back telephone number bit 7 6 5 4 Send login word 0000 1001 Send security password 0 9 1010 1111 reserved S55 backup speed V 34 33600 V 21 300 S56 13 dBm Dial Line Tx Level S57 00 binary Bit Mapped Options bit 1 0 retrain threshold 00 High 65 APPENDIX 1 T 336Cx S REGISTER TABLE S58 S59 s60 0 decimal 66 01 medium 10 Low 11 reserved bit 2 reserved bit 3 Security password pass through bit 7 6 5 4 reserved Retrain times 0 255 default 2 Profile Checksum Power up ATR Yn APPENDIX 2 T 336Cx LCD MENU QUICK REFERENCE APPENDIX 2 T 336Cx_LCD MENU QUICK REFERENCE Version screen Main Screen Version screen V 34 Modem V 2 XX BA 8 050 V34 Adapt V42bis D ANS Standby SN XXXXXXXXXXXX gt V 2 XXxX BA 8 050 L TARGET SELECT LOCAL lt L TARGET SELECT REMOTE ENTER KEY EXIT KEY gt KEY lt KEY Scroll item amp parameter by gt or lt Note1 Only available when connected and Note 1 Remote Access function is enabled Tx Level Dial a Number Protocol Type Clear All Speed Rx Level Edit a Number Discon Method LAL ORG ANS Mode l S N Ratio Ring Times Login Check DL Auto Retrain EQM Progress Tone Send password RDL Tx Clock T F Shift R
16. to the most of the Sync 4 wire leased line Async 2W leased line answer applicable to the most of the async compressed 2 wire leased line Store the revised user defined configuration profile VStore in the nth group in the user s configuration profile Usually the Oth group is provided for the working area setting store in this area or load the factory default will change the set parameters for next power on operation If you want the nth group is to be used for the next power on working profile operate the load user profile n configuration in the Front panel lock control No limitation for any front panel operation default Allow view the status and current setting of the modem but can not make any changes of setting For changing password use left key L right key R enter key E exit key X Home key V The password by the factory are REEE right moving key ENTER ENTER ENTER select the user profile to be used on power up Re initialize the user profiles to the Factory CHAPTER 3 FRONT PANEL AND MENU TREE Are you sure Serg edit Base DEC Base Bin XX 35 ATSn m profile 0 and flush the stored telephone numbers confirm the initializing action Press enter key to confirm or any other key to quit Edit the contain of the selected sreg Edit the value of the S register in decimal form Edit the value of the S register i
17. tone on off 0 calling tone off 1 calling tone on read DSP ram content for test only write DSP ram content for test only 52 CHAPTER 5 INSTRUCTION SETS 5 2 Dial Modifiers Table 5 2 Dial Modifiers for AT and V25bis command enable tone dial enable pulse dial 0 to 9 dial digit A to D a to d ma gp INN CN W or w wait for dial tone r ut WEN return to idle after dial O or wait for quiet answer silence 9 intelligent dial polling reverse to the answer mode dial stored tel number n cascade the tel number to the next one or or do nothing or 53 CHAPTER 5 INSTRUCTION SETS 5 3 Result Codes 54 Table 5 3 AT Command Result Codes CO CN CHAPTER 5 INSTRUCTION SETS 55 Table 5 3 Result Codes cont CHAPTER 5 INSTRUCTION SETS 5 4 V 25bis Auto call Unit V 25bis auto call unit is used for auto calling in asynchronous and synchronous data formats 1 V 25bis Commands a CRNx b CRSy c PRNy x d REN e CIC f DIC 2 V 25bis Responses a INC b INV c VAL d LSN e CNX Call request dial a phone number x entered on DTE keyboard Call request dial a phone number stored in specified memory address y y 0 9 Program number store a phone number x in specified memory address y y 0 9 Request list of all stored numbers Connect incoming call Auto answer enable Disregar
18. 00 Default 10101101 100ms 10ms binary binary Unit binary 10 reserved 11 reserved bit 3 2 reserved bit 7 4 Login check 0000 1001 0 9 1010 ALL 1011 By NMS 1100 1111 Disable security check DTR Debounce Time bit 3 2 1 0 DTR drop detection time bit 7 6 5 4 DTR rising detection time RTS to CTS Delay Bit Mapped Options set clear bit1 0 data mode data format 000 AT amp QO0 amp MO async data mode 001 AT amp Q1 amp M1 sync data mode 010 reserved 011 reserved bit 2 remote status enable disable bit 3 remote access on remote access off bit 5 4 sync transmit clock source 00 AT amp X0 internal clock 01l AT amp X1 external clock 10 AT amp X2 slave loopback clock 11 reserved bit 7 6 line type 00 AT amp LO dial line 01 AT L1 2 wired leased line 10 AT L2 4 wired leased line 11 reserved Bit Mapped Options bit 0 1 2 to 35 dBm receive dynamic range 0 12 to 44 dBm receive dynamic range bit 1 reserved bit 3 2 disconnect option 00 send clear down before disconnect 01 immediately disconnect 10 reset modem on disconnect 11 reserved bit 5 4 ENQ ACK control 00 ANHO no ENQ ACK 01 AHI to host simulate peripheral 10 AT H2 to peripheral simulate host 11 reserved bit 6 fix speed function bit 7 reserved Function Description Bit Mapped Options bit 1 0 command selection 00 dumb mode 01 Hayes AT comman
19. 1 TAINET MODEM INTRODUCTION 1 1 Description The TAINET Network Series Modem T 336Cx Nx NDx are high performance synchronous and asynchronous full duplex multi standard modems designed for use on 2 wire dial circuits and 2 4 wire leased lines The MODEM series fully comply with ITU T V 34 gt V 32bis V 32 gt V 22bis V 22 V 23 V 21 and BELL 212A 103 gt speed 115200 300bps Asynch gt 33600 1200bps Synchronization In V 34 and V 32bis V 32 modes echo concellation provides 2 wire full duplex operation over all PSTN circuits including those with satellite sections Compatibility is also provided with Bell 212A and Bell 103 operating standard V 34 mode provide full duplex operation at up to 33 6 kbps speed with line probing symbol rate and carrier frequency selection technologies V 34 mode also use other advance technologies such as Adaptive Precoding Non Linear Encoding Warping Constellation Expansion Multidimensional Trellis coding and Shell Mapping Tx power back off Power Reduction There are 10 factory default profiles and 10 user s profiles for your easiest configuration setting Allow up to 16 modem cards T 336Nx with 16 port on a rack shelf TRS 16 Allow up to 16 modem cards T 336NDx with 32 port on a rock shelf TRS 32 A 2 by 16 characters LCD display on the front panel with back lighted control for configuration set up and monitoring conveniently Line status monitoring including transmit
20. 7 At Cn AT CO AT C1 TEST MENU Command AT amp TO AT amp T1 AT amp T6 AT amp T3 AT amp T4 AT amp T5 AT amp T10 password Time required for sending password is about 2 seconds Control code can be applied in 0 9 Call back telephone number Assign one of the stored phone number 0 9 as the Call Back Number Control codes such as lt lt gt should not appear in phone number The period ANS modem will delay before start Call Back procedure from Idle to Dial When this option is set to Disable all Call Back related function will also be disabled including Dynamic Callback assignment function Control of the data compression function disable data compression function use V42 or MNP4 error correction only enable data compression function use V42bis or MNPS data compression in addition to V42 or MNP4 error correction Description Clear all the tests in one time and a statement Has been done shall be shown Local analog loop test ON OFF This test is normally used to certify if the modem is in normal operation condition Also this test is usually carried out together with B E R test For remote digital loop test ON OFF This test can control remote modem to executive digital loop for BER test to find out if the modem and line of both ends are in normal condition For digital loop test ON OFF This test enable the received digital data demodulated and send ba
21. 8800 bps 31200 bps 33600 bps 38400 bps 57600 bps 76800 bps 115200 bps Flow Control AT Qn Used to set flow control between terminal and modem when using V 42 MNP and normal mode asynchronous mode only Off ATIQO No flow control X ON X OFF AT Q1 Software control used in text data CTS Only AT Q2 Hardware control identical to RTS CTS control but modem send the data in spite of RTS from DTE unilateral control RTS CTS AT Q3 Hardware control bilateral accept any type of data default DTR CTL AT Dn Modem action select for DTR from OFF to ON 108 2 AT DO Same as V 25 108 2 DTR operation default 108 1 AT D1 Same as V 25 V 25bis 108 1 DTR operation When DTR is from OFF to ON the modems will dial the designed preset telephone number or answer according to the current ring count DTR Off Action AT amp Dn On originate and answer site respectively modem action select for DTR from ON to OFF Forced On AT amp DO Force DTR in ON position A power on auto dial operation can be achieved when operating with DTR ON auto dial default Command mode AT amp D1 Return to the command mode 30 CHAPTER 3 FRONT PANEL AND MENU TREE Disconnect MODEM Reset DSR Control Normal Forced on DCD Control Forced on Normal V 13 HDX V 23 HDX RTS Control Normal Forced on Data Format Async Sync Total bits 8 9 10 11 AL by 141 On Off RDL by 140 On Off 31 AT amp D2 AT amp D3 AT amp Sn AT amp
22. CM SM AT B34 Set modem speed to V34 14400 bps 4DTCM SM AT B38 Set modem speed to V34 12000 bps 4DTCM SM AT B33 Set modem speed to V34 9600 bps 4DTCM SM AT B32 Set modem speed to V34 7200 bps 4DTCM SM AT B31 Set modem speed to V34 4800 bps 4DTCM SM AT B40 Set modem speed to V34 2400 bps 4DTCM SM AT B47 Set modem speed to V 32 Auto auto detact V 32b V 32 V 22bis V 22 V 21 AT B20 Set modem speed to V 32bis 14400 bps TCM AT B19 Set modem speed to V 32bis 12000 bps TCM AT B18 Set modem speed to V 32 9600 bps QAM AT B17 Set modem speed to V 32 9600 bps TCM AT B16 Set modem speed to V 32bis 7200 bps TCM AT BI15 Set modem speed to V 32 4800 bps QAM AT B9 Set modem speed to V 26 2400 bps DPSK AT B8 Set modem speed to V 26 1200 bps DPSK AT B7 Set modem speed to V 23 1200 bps FSK AT BS5 Set modem speed to V 22bis 2400 bps QAM AT B3 Set modem speed to V 22 1200 bps DPSK AT B1 Set modem speed to V 21 300 bps FSK AT B4 Set modem speed to BELL 212A 1200bps DPSK AT B2 Set modem speed to BELL 103 300 bps FSK ATS14 n Set modem as the originate or answer mode bit7 Originate site Answer site AT En The automatic adaptive equalizer can be re adjusted via retrain procedure activated automatically when the S N become worse than the preset threshold AT E1 Retrain occurs automatically according to SQ EQM value default AT EO Auto retrain disable AT amp Xn Select transmit clock source AT
23. D displayer The T 336Cx has a 2 by 16 characters LCD with auto backlight control Some different pictures of the LCD display are shown below A Top Menu Example V34 336 V42bis D ANS CONNECT 9 Description 1 Modem Protocol V34 336 V34 312 V34 288 V32b 144T V32 96T V22b 24 2 Data Protocol V 42bis V 42 MNP 5 Normal Direct 3 Line Type D Dial Line L Leased Line 4 Mode ANS Answer Mode ORG Originate Mode 5 Status Stanby Handshaking Connect Retrain Ring 6 SO Signal quality 9 8 7 6 0 CHAPTER 3 FRONT PANEL AND MENU TREE B Menu Select Exp 1 Exp 23 L MENU Select L MENU Select STATUS TEST Description 1 In top menu press ENTER key to enter this menu 2 Select LOCAL or REMOTE first if connected and remote access function enabled 3 The character L on the upper left corner stands for local 4 You may use P and qu keys to select menu 5 Press ENTER key to enter the MENU 6 Press EXIT key to quit from this menu 7 Note that status menu is not available before connection C Menu Screen Exp 1 Exp 2 L STATUS R CONFIG MODEM RX Level 10dBm TX clock Exp3 Exp 4 L TEST L DIAL LAL ON Dial a number Description 1 L Local R Remote 2 Menu name STATUS TEST DIAL 3 Status or setting RX Level 10dBm LAL ON 4 Use P or q keys to shift among fields press ENTER key to enter the selected menu D Set up Menu
24. DTE Interface EIA RS 232C CCITT V 24 V 28 Pn 24 DESCRIPTION Source C1 101 60 Protective Gromd _ 6107 DSR Data Set Ready MODEM 7 102 SG Signal Ground O 7 e 109 DCD Data Carrier Detect MODEM a Ta vbc MOD J 0 ewe moe CHAPTER 1 TAINET MODEM INTRODUCTION 1 3 Ordering Information T 336Cx Stand alone V 34 33 6kbps modem T 336Nx Rack mounted V 34 33 6kbps modem card TRS16 T 336NDx Rack mounted V 34 33 6kbps modem card TRS32 T 336Cx t Stand alone V 34 33 6kbps modem T 336Nx t Rack mounted V 34 33 6kbps modem card TRS16 T 336NDx t Rack mounted V 34 33 6kbps modem card TRS32 NMC16 NMS Control unit TRS16 NMC32 NMS Control unit TRS32 TRS16 19inch rack up to 16 modem card TRS32 19inch rack up to 32 modem card PW 130AC 90 265 VAC 130W power unit for rack PW 130DC 36 72 VDC 130W power unit for rack PW 132A 90 265 VAC 130W power unit for rack PW 132D 36 72 VDC 130W power unit for rack A50 50 pin cable with standard centronic connector for TRS32 TB32 The rear panel terminal block module board of the TRS32 for 2 4 wire Leased and Dial line connection TAINET MANAGERO Network Management System CHAPTER 2 INSTALLATION 2 1 2 2 2 3 2 4 2 5 2 6 2 7 CHAPTER 2 INSTALLATION Description Unpacking Site Reguirements Site Selection AC Electrical Outlet Connection Connecting With Dial Line Connecting With Leased Line CHAPTER 2 INSTALLATIO
25. N CHAPTER 2 INSTALLATION 2 1 Description This chapter provides the information needed to install the TAINET Network Series Modem and to ensure that it is working properly You may obtain more information about this subject for rack mount modem shelf from the User s Manual of TAINET TRS16 or TRS32 rack mount modem shelf 2 2 Unpacking Save the carton and protective packing material in which your TAINET Network Series Modem was shipped you might need them for repackaging if you have to store or ship the modem in the future The following items are shipped with your modem One Modem User s Manual One 7 feet 2 13m modular telephone cable for connection to RJ45 8 pin jack or one site is RJ 45 and the other site is Utype option One 7 feet 2 13m modular telephone cable for connection to an RJ11 4 pin jack One 8 pin RJ 45 box for leased line application One 6 feet power cord Rough handling during shipping causes most early modem failure after you unpack the modem check carefully for shipping damage Contact the shipper if you notice any damage Direct any additional questions about damaged or missing parts to the nearest sales representative 2 3 Site Requirements The FCC requires telecommunications equipment to withstand electrical surges which may result from lightning strikes the TAINET Network Series Modem meet the requirements set forth by the FCC Make sure the electrical service in your building is prope
26. OFILE MENU Load Power Up Initial Front Lock Password Edit Sreg Edit Save 22 Off On User Profiles 0 49 0 AS DL AT AUTO 1 AS DL AT NONE 2 SY DL V25 NONE 3 AS 2L ANS V34 4 AS 2L ORG V34 5 SY 2L ANS V34 6 SY 2L ORG V34 7 SY 4L ANS V34 8 SY 4L ORG V34 9 AS 2L ANS AUTO User Profile 0 9 Are You Sure Unlock Lock Input BASE DECIMAL BINARY User Profiles 0 49 CHAPTER 3 FRONT PANEL AND MENU TREE 3 5 Detailed Description of the Menu Tree 3 5 1 Ttem Name TX LEVEL dBm XX RX LEVEL XX dBm S N RATIO XX dB EQM VALUE XXX F SHIFT XX Hz F F SHIFT XX Hz DELAY XXXX ms P JITTER X Deg F ECHO XX X dB DTE XXXXX ASY 10 RETRAINS XXXX 23 Command AT S AT S AT S AT S AT S AT S AT S AT S AT S AT S AT S STATUS MENU Description Transmitted signal level This value is equal to the TX level of config modem Normally for the 2w leased line and the dial line the recommended value is between 10 and 13dBm It can be increased of in order to obtain a more satisfactory S N ratio signal to noise ratio by setting a higher level as possible but a saturation of the active transmission equipment should be avoided The Tx level level should be setting under 13dBm while to operating V 34 mode Received signal level This value is the result of the line attenuation from the transmitted signal Normally the RX level o
27. T V 25bis command set with async Bisync and HDLC SDLC formats Dumb mode don t accept any command This mode is set for all leased line and most of the sync dial line to prevent modem from interference made by the data of the terminal and protect the terminal against any malfunction caused by the return result code from the modem Auto baud rate detection function control for AT command mode Enable default Disable V 25bis command data format Async default HDLC SDLC Bisync monosync Select the Async data parity 7 Data Bits odd parity 1 stop bit 7 Data Bits even parity 1 stop bit 7 Data Bits none parity 2 stop bits 8 Data Bits none parity 1 stop bit default Select the char to be transmitted for the BSC amp HDLC faming No character to be Tx when idle SYNC char be Tx when idle CHAPTER 3 FRONT PANEL AND MENU TREE 3 5 8 LINE SETUP MENU Command Ttem Name Line Type Dial Line 2W Leased 4W Leased Leased to Dial Manual Auto Backup Tel No dial backup 0 nnmn to 9 nnnn Backup Speed V34 Adapt to V21 300 Dial To Leased Manual Auto D to L Timer Forever 1 255 mins Dial To Dial Off On 33 AT amp Ln AT amp LO AT8L1 AT amp L2 ATS31 n bit0 ATS55 n ATS31 n bit1 ATS36 1 ATS42 n bit3 Description Select line type and also set dial back up function Dial line 2 wire leased line 4 wire leased line Auto dial b
28. TAINET MODEM T 336Cx Nx NDx User Manual The Professional Partner TAINET COMMUNICATION SYSTEM CORP Headquarters Beijing Branch No 25 Alley 15 Lane 120 3F A Building 113 Zhi Chun Lu Sec 1 Nei Hu Rd HaiDian District Beijing China Taipei 114 Taiwan Zip Code 100086 TEL 886 2 26583000 TEL 86 10 62522081 87 FAX 886 2 26583232 FAX 86 10 62522077 v1 7 07008 00027 2004 11 15 Contents CHAPTER 1 TAINET MODEM INTRODUCTION w wswsemsemewowa 2 Als Descipiom ua AA 2 12 Technical Sp cifications tia dad 3 1 3 Ordering O kia 7 CHAPTER 2 INSTALLATION wai odo 10 DA A O WA AHA SAA 10 22 Unpacking AA WA NA WASIA 10 2 3 Site REQuiremen Hi 10 WASI NO AA KA NI MA ath ce a aah 11 2 5 AC Electrical Outlet Connection w wwwwmmenmesmmammnm nna nimm aim wi mm 11 2 6 Connecting With Dial aa 12 2 7 Connecting With Leased Line ai A Aaa 13 CHAPTER 3 FRONT PANEL AND MENU TREE 16 3 1 The Front Panel Description w wwmmwwemenmmmmmnnmnimminamammmamam ama 16 3 2 The Rear Panel Descrip dae 16 3 3 Operating the TAINET Network Series Modem cooocococonoocccoonconncconcconnnonnnconncnnno 17 3 4 The Menu A O TE 19 3 5 Detailed Description of the Menu Tl88O ooonccnnnccnonccconoconononnnonononnnonncnnn ccoo nccononnnos 23 3 5 1 STATUS MENU a Nawa 23 3 5 2 DIAL MENO serios tal 25 3 5 3 PROTOCOL MEN edo 26 3 5 4 TEST MENU ita 27 3 5 5 CONFIG MODEM MENU escusa 28 3
29. TE Equipment two RJ11 telephone jack for connecting to dial line and telephone set and one RJ45 telephone jack for connecting to 2 wire or 4 wire leased line as illustrated below For more detailed description please refer to Chapter 2 Installation of this manual DTE PHONE LEASED LINE DIAL LINE gt ae a Figure 3 2 TAINET T 336Cx Rear Panel 16 CHAPTER 3 FRONT PANEL AND MENU TREE 3 3 Operating the TAINET Network Series Modem 1 17 Key Total 5 keys as follow VO DA It is used as the voice data select key for dial line application Disconnect Reconnect selection for leased line applications or home key for set up menu to go back to the home menu 4 Left key It is used to shift to left field Right key It is used to shift to right field or next item ENTER Enter key It is used to enter the next lower level menu or confirm selections EXIT Exit key use it to go back to the upper level menu LED indicator total 10 indicators as following PWR On for power supply ok DTR On for DTR signal present DSR On for DSR signal present RTS On for RTS signal present CTS On for CTS signal present TXD On for 0 off for 1 TXD signal present DCD On for received carrier signal DCD present RXD On for 0 off for 1 RXD signal present OH On for Off Hook TST On for test mode active LC
30. TRL _ON ON Normal ON ON ON Disconnect clear immediate clear clear clear clear clear clear Method down down down down down down down S gt a E 5 uu 7600 V42 bis N O Q pr i pa Z Z 3 LII olola z IPI MET Els 2 ela an soo Z Z 3 3 E A As Z 2 3 3 2 a ziz 8 elojo le 2 E Z Z 5 EJE E 4 8 Remote Access For improving service loading the T 336Cx offer a remote access function through secondry channel It can read and write the parameter of the remote site modem from local site for well maintenance purpose To use this function the Remote Access under CONFIG MODEM menu must set to be on 4 9 Multi standard Handshake The T 336Cx complys with ITU T recommendations V 34 V 32bis V 32 V 22bis V 22 V 21 V 8 V 42 and V 42bis operating standard This functions in both calling and answering mode to automatically recognize the remote modem standard and connect to it accordingly 41 CHAPTER 4 GENERAL INFORMATION AND FEATURES 4 10 Auto Dial Back Up When you apply T 336Cx to leased lines no matter what protocol you are using in case that the lines don t function well you may allow modem dial a stored number via a dial line to rebuild the connection This line is called back up line While using the back up line the modem periodically checks the recovery of leased lines to find the opportunity to go back to leased lines in order to save the charge of dial line T
31. Timer Connect Code Compress D TEST MENU Clear All LAL DL RDL RDL Grant Error Count B E R Test E CONFIG MODEM MENU Modem Speed 20 0 nnnn 1 nnnn 49 nnnn 0 nnnn 1 nnnn 49 nnnn Auto ANS Off Times 255 Times Basic Code Don t Care Dial Tone Busy Tone Dial Busy Tone Immediate 1 255 Second Tone Pulse Until DCD on Always on Off when Low Medium High Normal Direct Reliant MNP Auto Reliant LAPM LAPM Normal LAPM MNP MNP Normal Immediate With Clear down Modem Reset Disable 0 9 ALL By NMS OFA 0 49 0 9 Disable 1 255 Seconds DTE Speed DCE EC DTE Speed DCE Speed Off On Has Been Done Off On Off On Off On Off On 0 65535 Off 511 V 34 Adaptive V34 336 V34 312 V34 288 V34 264 V34 240 V34 216 V34 192 V34 168 V34 144 V34 120 V34 96 V34 72 V34 48 V34 24 V32b Adaptive V32b 144 V32b 120 V32 96Q V32 96T V32b 72 V32 48 V26b 24 V26b 12 V23 1200 V22b 2400 V22 1200 BELL 212A BELL 103 V21 300 CHAPTER 3 FRONT PANEL AND MENU TREE ORG ANS Mode Auto Retrain Tx Clock Retrain Threshold ASI Overspeed Make Break Force Off Hook OH by DTR Pump Edit FB FF Ctrl LL Tx Level DL Tx Level Remote Access Dynamic Range F CONFIG DTE MENU DTE Speed Flow Control DTR Off Action DTR Control TS Control DSR Control DCD Control Data Format Total Bits AL by 141 RDL by 140 G COMMAND MENU Command Mode Auto Baud Framing Async Form Idle
32. ack up control while leased line is out of service Manual control default Auto dial back up Select backup telephone number n n 0 9 Disable backup function default Enable backup function and make a choice of the phone number group Select modem speed used in the auto dial backup mode default V 34 288 Select whether return to leased line automatically or not during dial back up mode Manual control default Return to the leased line automatically when leased line is recovered When operate in dial back up mode to select how long it will take to detect if the leased line is recovered or not No dial to leased default 60 minutes When dial line is in use excluding dial back up mode the line can be restored by auto redial after line disconnection Disable default Any abnormal line disconnection shall automatically redial to connect CHAPTER 3 FRONT PANEL AND MENU TREE 3 5 9 PROFILE MENU Item Name Command LOAD ATZn n 0 9 User Defined User Profile 0 9 AT amp Zn Default profile AT amp Fn amp W 0 AS DL AT AUTO AT amp FO amp W 1 AS DL AT NONE AT amp FI amp W 2 SY DL V25 NONE AT amp F2 amp W 3 AS 2L ANS V34 AT amp F3 amp W 4 AS 2L ORG V34 AT amp F4 amp W 5 SY 2L ANS V34 AT amp F5 amp W 6 SY 2L ORG V34 AT amp F6 amp W 7 SY 4L ANS V34 AT amp F7 amp W 8 SY 4L ORG V34 AT amp F amp 8 amp W 9 ASY 2L ANS AUTO AT amp F9 amp W SAVE AT amp Wn n 0 9 U
33. ail Rmt RXL low Rmt RXL high Rmt SNR bad Rmt DTR off Rmt N Echo No Dial Tone Dial Backup Card Fail 68 External Clk 2400 4800 7200 9600 12000 14400 16800 19200 21600 24000 26400 28800 31200 33600 36000 38400 40800 43200 45600 48000 50400 52800 55200 57600 J ENTER KEY T EXIT KEY Ve gt KEY lt lt KEY Card Selection CARD KEY Go to the top layer of menu tree HOME KEY RS 485 port ASYNC_HDX NAK COUNT ae ee RS 232 with CTS HDLC_NRZI_HDX BCC COUNT Py RS 232 no CTS HDLC_NRZ HDX Pending Block HEHEHEHE
34. amp X0 Internal clock source for most point to point application default AT amp X1 External clock source for cascade and TDM STDM network application AT amp X2 Received clock source for used in slave side of polling networks or the modem in the most far end of a cascading network CHAPTER 3 FRONT PANEL AND MENU TREE LL TX Level 0 31 dBm DL TX Level 0 15 dBm ASI Overspeed HI Yo 2 3 Make Break UK 33 3 US 39 Force OFF Hook OH by DTR On Off RTRN Threshold High Medium Low Pump Edit FB FF CTRL On Off Remote Access On Off Dynamic Range 12 44dBm 2 35 dBm 29 ATS30 n ATS56 n AT An AT AO AT A1 AT amp Pn AT amp P1 AT amp PO ATHI ATS19 n bit 6 ATS57 n bitl 0 AT Gn AT GI1 AT G2 ATS27 n bit3 ATS28 n bit0 Set leased line transmit level 13dBm default Set dial line transmit Level 13dBm default Select async data speed tolerance ITU T V 14 Basic range 1 to 2 5 default Extended overspeed range 2 3 to 2 5 Pulse dial make break ratio selection 33 3 66 7 default 39 61 Force modem off hooking the line to busy out the in coming calls Make the modem to off hook the line when DTR being off for a period of time enable the OH By DTR function disable the OH By DTR function default Select the scaleable retrain threshold for determining the data rate of the connection
35. ck to match with the far end test Set for accepting remote digital loop RDL test Enable default Disable Bit error count display function Press Left or Right shift key to insert error Press ENTER key to clear Set bit error rate test function Disable default use the 511 test pattern CHAPTER 3 FRONT PANEL AND MENU TREE 3 5 5 Item Name Speed V34 Adapt V34 336 V34 312 V34 288 V34 264 V34 240 V34 216 V34 192 V34 168 V34 144 V34 120 V34 96 V34 72 V34 48 V34 24 V32b Adapt V32b 144 V32b 120 V32 96Q V32 96T V32b 72T V32 48 V26b 2400 V26b 1200 V23 1200 V22b 2400 V22 1200 V21 300 BELL 212A BELL 103 ORG ANS Mode Originate Mode Answer Mode Auto Retrain On Off Tx Clock Internal External Loopback 28 CONFIG MODEM MENU Command Description AT Bn Set modem speed and protocol AT BO Set modem speed to be V 34 adaptive multi standard hand shaking mode connectable speed from V 34 V 32b V 32 V 22bis V 22 V 21 Only work for Dial Line AT B42 Set modem speed to V34 33 6k bps 4DTCM SM AT B41 Set modem speed to V34 31 2k bps 4DTCM SM AT B28 Set modem speed to V34 28800 bps 4DTCM SM AT B37 Set modem speed to V34 26400 bps 4DTCM SM AT B27 Set modem speed to V34 24000 bps 4DTCM SM AT B36 Set modem speed to V34 21600 bps 4DTCM SM AT B26 Set modem speed to V34 19200 bps 4DTCM SM AT B35 Set modem speed to V34 16800 bps 4DT
36. d incoming call Auto answer disable Modem detects an incoming call Modem received invalid command entry Modem received valid command entry Modem responses LSN when received RLN command Connection 3 V 25bis Call Failure Responses a CFIET b CFIAB c CFIRT d CFICB e CFINS f CFIND 56 Busy tone had been detected Modem aborted a call Ringback timeout Modem busy No phone number is stored No dial tone is detected CHAPTER 6 MAINTENANCE 57 CONTENT 6 1 Description 6 2 Instruments 6 3 Periodic Maintenance 6 4 Troubleshooting 6 5 Return Procedure CHAPTER 6 MAINTENANCE CHAPTER 6 MAINTENANCE CHAPTER 6 MAINTENANCE 6 1 Description This chapter gives you the information of maintenance and the required instruments in order to let you recover the troubles quickly 6 2 Instruments The only instrument you need is a mult meter due to the embedded digital and analog test abilities 6 3 Periodic Maintenance For every three months you should do the following jobs A Turn the power off clean the modem check the plugs make sure all the connectors are connected firmly B Be sure that the indicators function well 6 4 Troubleshooting Once the TAINET Network Series Modem malfunctions please check and record the indicators at the moment then turn the power off Consequently make sure the IC s on printed circuit board are firmly sited Try to turn the power on again if the troub
37. d mode 10 V 25bis command mode 11 reserved bit 2 0 Line break Send continuous space bit 3 0 AT EO auto retrain off AT E1 auto retrain on bit 4 0 front panel unlock APPENDIX 1 T 336Cx S REGISTER TABLE 1 front panel lock bit6 5 00 AT GO auto FB FF disable 01 AT G1 auto FB FF enable 10 AT G2 Auto FF off but FB on 11 reserved bit 7 0 AT U0 autobauding off 1 AT UI1 autobauding on S30 13 dBm Leased Line Tx Level 0 31 dBm S31 00000000 binary Bit Mapped Options bit 0 leased to dial 0 manual 1 auto bit 1 dial to leased 0 manual 1 auto bit 2 V 32 auto FFFB by Retrain bit 3 reserved bit 7 6 5 4 backup tel 0 9 no dial backup S32 0 reserved S33 Test time minute S34 Test time second S35 30 second OH by DTR timer default 30 seconds S36 D to L timer default 60 mins S37 2 second Redial delay Immediately 1 255 Second S38 00000000 binary V34 Baud Rate Selection bit 0 enable 2400 disable 2400 bit 1 reserved this bit always must be set bit 2 enable 2800 disable 2800 bit 3 enable 3000 disable 3000 bit 4 enable 3200 disable 3200 bit 5 enable 3429 disable 3429 bit 7 6 Break type during Normal V 42 or MNP operation 00 AT KO break 0 destructive 01 AT K1 break 1 nondestructive 10 AT K2 break 2 queue 11 reserved S39 reserved S40 Call back time unit second 0 Disable acll back 1 255 Second S41 00000001 binary Bit Mapped Opti
38. e mode and an answer mode You may find the information of originate answer settings in the ORG ANS MODE column of CONGIF MODEM MENU Note that the modem will automatically determine either mode whenever you use the AT commands front panel dialing or auto answering 39 CHAPTER 4 GENERAL INFORMATION AND FEATURES 4 5 Synchronous VS Asynchronous The data formats of both connecting modems must be exactly the same in order to exchange data with each other There are synchronous and asynchronous data formats The common personal computers and terminals are asynchronous Whereas the host computers and their terminals are often synchronous For most multiplexes the connecting modems should be synchronous However the user should know the type of the data terminal equipment DTE to get proper operation Except V 21 V 23 and Bell 103 which only can operate in asynchronous mode other protocols can run in either mode About the settings of this issue you may find it at Data Format column of CONFIG DTE menu Note that if the asynchronous mode is selected you need to set Data Bits DTE Speed as well On the other hand if you operate the modem with AT command it will automatically determine these parameters 4 6 Error Correction And Data Compression The TAINET Network Series Modem supports Error Correction and Data Compression while operating in asynchronous mode In
39. e remote modem This value is only available when operating on V 34 TR MR RS CS CD T AT S Indication of the RS 232 interface lead status 24 CHAPTER 3 FRONT PANEL AND MENU TREE 3 5 2 Ttem Name Dial a Number 0 49 Edit a Number 0 49 Ring Times Auto Ans Off 1 255 Times Progress Tone Basic Don t Care Dial Tone Busy Tone Dial Busy Tone Redial Delay Immediately 1 255 seconds Dial Type Tone Pulse SPK Control Off Until DCD On Always On Off When Dial SPK Volume Low Medium High 25 DIAL MENU Command ATDSn AT amp Zn xx ATS0 n ATSO 0 ATXn ATXO ATXI ATX2 ATX3 ATX4 ATS37 n ATS37 0 ATS37 n ATT ATP ATMn ATMO ATM1 ATM2 ATM3 ATLn ATLO ATL1 ATL2 Description Dial out a preset telephone number n n 0 9 This function can interact with the auto redial function or dial line auto establishment function Edit telephone number n n 0 9 for up to 20 digits each group If the is included inside the number and auto redial is ON then it will redial next number after no answer until the number without If it is still unsuccessful then retirn to the first number Up to 10 intelligent redial group is allowed 1 XXX gt 2 xxx gt n xxx gt 1 xxx gt Auto answer activates when detected ring count n default 1 1 108 1 DTR ON Auto Dial Ans is used for auto answer it must be set to OFF and the answer shall be ac
40. ed 10 always on 11 off when dial result code and call progress 000 ATXO CONNECT without speed message blind dial no busy tone Basic Code 001 reserved 010 reserved 011 reserved 100 ATX1 CONNECT with speed message blind dial no busy tone Dialn Tone 101 ATX2 CONNECT with speed message wait for dial tone no busy tone 110 ATX3 CONNECT with speed message blind dial check busy tone Busy Tone 111 ATX4 CONNECT with speed message wait for dial tone check busy tone Dial Busy Tone 0 AT amp PO Make Break ration USA 39 AT amp P1 Make break ratio UK 33 3 Bit Mapped Options set clear 0 AT amp T5 slave RDL disabled AT amp T4 slave RDL enabled 0 RDL by 140 disable 1 RDL by 140 enable 0 AL by 141 disable 1 AL by 141 enable 0 ATAAO basic ASI 2 5 to 1 1 AT A1 extended ASI 2 5 to 2 3 data length on direct mode 00 8 bits 6 N 1 01 9 bits 7 N 1 10 10 bits 8 N 1 bit 7 6 11 11 bits 8 Stuff Parity 1 guard tones 00 AT8GO Disabled Default 01000000 Unit binary No S24 bit 1 0 61 01 AT amp G1 10 AT amp G2 11 reserved 550 Hz 1800 Hz Function Description Bit Mapped Options DTR off to on control 00 AT DO normal 108 2 01 AT DI dial ans according to ring in 108 1 APPENDIX 1 T 336Cx S REGISTER TABLE S25 S26 S27 S28 S29 62 00 0 00001000 000000
41. ed bit 7 6 test pattern selection 00 reserved 01 AT TI 511 pattern 10 reserved 11 reserved reserved Modem Test Timer minute Bit Mapped Options set clear bit 0 1 V25bis character framing 00 Async 01 HDLC 10 BSC 11 reserved bit 2 1 NRZ 0 NRZI bit 3 1 flag idle 0 mark idle bit 5 4 word length 00 7 bit data even parity 1 stop bit 01 8 bit data no parity 1 stop bit 10 7 bit data odd parity 1 stop bit 11 7 bit data no parity 2 stop bit bit 6 DTR off cause busy out nothing bit 7 0 V 32bis fast training disable 1 V 32bis fast training enable Reserved Bit Mapped Options bit 1 0 DCD control 00 ATRCO DCD forced on 01 AT amp C1 DCD on after connect 10 V 13 HDX 11 V 23 HDX bit 2 0 AT amp RO RTS normal AT amp R1 RTS forced on bit 4 3 DTR on to off action 00 AT amp DO Ignore force on 01 AT D1 recall command mode 10 AT amp D2 Disconnect 11 AT amp D3 reset modem bit 5 0 CTS off in retrain CCITT 1 CTS follows RTS EIA Function Description bit 6 0 AT amp SO DSR forced on 1 AT amp S1 DSR on after connect bit 7 reserved APPENDIX 1 T 336Cx S REGISTER TABLE S22 01110110 binary bit 1 0 bit 3 2 bit 6 5 4 bit 7 S23 00100001 binary bit 0 bit 1 bit 2 bit 3 bit 5 4 Bit Mapped Options speak volume 00 low 01 medium 10 high 11 reserved speak control 00 off 01 speaker on until carrier detect
42. edial Delay Call Back No RDL Grant RTRN Threshold F F Shift Dial Type Call Back Timer Error Count ASI Overspeed E Delay SPK Control Connect Code B E R Test Make Break Phase jitter SPK Volume Compress Force Off Hook M F Echo OH By DTR DTE Pump edit Retrains FB FF Ctrl Menu Retrain LL Tx Level RX Baud DL Tx Level TX Baud Remote Access RX Freq Dynamic Range TX Freq RX Speed TX Speed Tx Power Off Interface indicators DTE Speed Command Mode Line Type Load Flow Control Auto Baud Leased To Dial Power Up DTR Off Action Framing Backup Tel Initial DTR Control Async form Backup Speed Front Lock RTS Control Idle Char Dial to Leased Password Edit DSR Control Dial to Leased Timer Sreg Edit DCD Control Dial To Dial Save Data Format Total Bits AL by 141 RDL by 140 67 APPENDIX 3 T 336Nx LCD MENU QUICK REFERENCE APPENDIX 3 T 336Nx_LCD MENU QUICK REFERENCE NMC 16 V5 xx 11 ID 001 01Select Menu 01Select Menu Modem Control Current Alarm gt 01Select Menu Ararm Config 1 7 LT y 01 Secect Menu 01 Current Alarm 01 Alarm Config gt RxL Low 3333333333333333 No alarm or alarm occu Group Setup P RXL High SNR Bad Chk Dial Line y T Dial Backup DTR Off TD RD Inactive N Echo High RXL Low RXL High V34 Adapt Direct D ANS Standby gt 01 Group Setup KXXXXXXXXXXXXXXXI SNR Bad lt DTR Off N Echo High Stand Alone TXD Inactive Modem Menu RXD Inactive Connect F
43. etting ANS modem will authenticate dial in modem with one of the stored phone number 0 9 timeout for waiting password from dial in modem is about 8 seconds Control code oh can be applied in 0 9 information about is described in section 4 17 Authenticate dial in modem with all stored phone number 0 to 9 Any successful match will force ANS modem to grant the access timeout for waiting password from dial in modem is about 8 seconds Control come can be applied in 0 9 If ANS modem is a card type model T 336Nx NDx the received password will be relayed to CS V1 5x for authentication Timeout for waiting password from dial in modem is about 8 seconds If ANS mdoem is a standalone model T 336Cx this option will be the same as ALL The program CS V1 5x is an additional software on CS server Assign the this option is effective only under ORG mode Assign the stored telephone number which will be sent out as password during dial out connection Disable the action of sending password this also disables the function of Dynamic Password assignment function Send one of the stored phone number between 0 9 as the CHAPTER 3 FRONT PANEL AND MENU TREE CallBack No 0 9 CallBack Timer Disable 1 255 Seconds Compress Off On 3 5 4 Item Name Clear All LAL OFF RDL ON OFF DL ON OFF RDL Grant ON OFF Error Count 0 65535 B E R Test OFF 511 2
44. even the power is off Users may choose the most similar factory default setting make some modifications with front panel or by AT commands from terminal then save the modified setting to a user profile From then on once the modem is turned on it will use this user profile as default You may find the Load Save selections in the PROFILE Menu where you can save the current configuration into the selected user profile or load the user or the factory profile Table 4 7 1 shows the default settings of each factory profiles Table 4 7 1 T 336Cx Factory Profile Default Settings Profile 3 4 5 6 SETTING ASY DL ASY DL SYN DL ASY 2L ASY 2L SYN 2L SYN 2L SYN 4L SYN 4L ASY 2L ITEM AT AT V25 ANS V34 ORG V34 ANS V34 ORG V34 ANS V34JORG V34 ANS AUTO NONE NONE Auto FORMAT DUMB DUMB DUMB LINE Type HA ee PA II T l MODEM V 34 V 34 V 34 V 34 288 V 34 288 V 34 288 V 34 288 V 34 288 V 34 288 V 34 288 SPD Adapt Adapt Adapt ORG ANS n n n ff N gt 2 aly ol2lQ ze 5 ais ro y S w Q Slelo AS Lo Bis Z 2 y 13dBm 13dBm 13dBm Tx level 13dBm Auto Retrain On On On On On On On DTE Speed 57600 57600 57600 PROTOCOL V42bis Direct Direct Direct Direct Direct Direct Direct n CTRL RTS CTRL ON ON Nomai ON ON Normal DCD CTRL Normal ON Normal Normal Normal Normal DTR OF DISCNT DSR C
45. f 2w leased line and the dial line is between 15 and 33dBm Signal to noise ratio The bigger the S N ratio the better quality of a line is A higher operating speed needs a higher S N ratio Normally the S N requirement of running 14400 bps should be more than 24 dB while to operate at 9600 bps a S N better than 20 dB is required Eye pattern quality monitoring This value represent the quality of receiving signal Frequency shift offset It is the shift of the carrier central frequency caused by the transmission link This shift normally should be less than 7 Hz The smaller is better Far end frequency shift offset The frequency shift of the far end received carrier signal It normally should be less than 7 Hz The smaller is better The value will not accurate once level is too small from the remote site Round trip delay time This delay is caused by a round trip of a long distance line especially in a satellite circuit Usually round trip of a satellite link shall create a time delay of 0 5 second 500ms The modem will accept a maximum time delay of 1 2 seconds Monitoring the phase jitter of the phone line Far end echo This echo is caused when the far end line impedance is not matched A smallest far end echo level is always required Normally the far end echo level is between 20 dB and 55 dB Indication of speed and data format of DTE For examples DTE 19200 ASY 10 stands for 19200 bps Asynchron
46. he modem s rear panel when it is not in use 2 4 Site Selection Locate the TAINET Network Series Modem no farther than 50 feet 15 24 meters from your data terminal equipment DTE and within 6 feet 1 83 meters of a grounded AC outlet furnishing the required power Install the modem in a clean area that is free from environmental extremes Allow at least 6 inch 15 24 cm in front of the modem for access to the front panel and at least 4 inch 10 2 cm in back for cable clearance Position the modem so you can easily see the front panel Do not stack another modem on top of TAINET modem For more detailed information on installation Modem Shelf TRS 16 and NMC 16 installation please refer the TAINET Rack Mounted Modem Shelf TRS 16 or TRS 32 User s Manual 2 5 AC Electrical Outlet Connection The power line associated with MODEM is about 2 meters three pins plug Middle cylinder is for grounding For power source adapting an automatic switching power supply 90 265VAC is used for the device the fuse for stand alone type is 2A for rack mount type is 4A The rack mount type is also capable for DC Source Power Supply option and its voltage range is 36 72VDC 11 CHAPTER 2 INSTALLATION 2 6 Connecting With Dial Line To connect your modem to a permissive RJ11 voice jack and dial line follow this procedure On the rear panel of MODEM there is an 8 pins RJ 45 jack used for Leased Line beside this there are two
47. his Control code overrides the setting of Call Back No in ORG modem If Send Password Off on ORG modem or Call Back No Disable this character will be ignored 4 17 2 Extension Code for Stored Phone Numbers lt char gt If the last two digits of Stored Phone Number is lt char gt modem will dial current number and continue on with specific stored number as designated by lt char gt lt char gt is the stored phone number order n any other characters after lt chart gt will be omitted For example ATDT1234 5 will force the modem to dial 1234 and the number stored in 5 Total number in a dial string should not exceed 250 characters The Code should not appear in Call Back Number or it will be ignored when ANS modem calling back 4 17 3 Additional Information a Front Panel LCD will show Call Back to indicate it is under Call Back mode When ANS modem is waiting under Call Back Timer to call back b When ORG modem dial with Dynamic Call Back Control Code gt lt string gt and sending Password for authentication no matter send with Send Password or Dynamic Password ANS modem will save received Password and send it back while Call Back link was built And it overrides the setting in its own Send Password c When modem is under Call Back operation VO DA can be used to cancel procedure d When applying Password or Call back Security functio
48. l 0 off 1 untill DCD on 2 Always 3 off when dial go online 0 go back to data mode 1 rate change 2 retrain 0 1 2 3 4 5 6 7 8 9 enable pulse dialing 47 CHAPTER 5 INSTRUCTION SETS 48 Function Description response on off 0 response on 1 response off S register read write ATSnn read s register ATSnn mm write value mm in decimal form to the s register nn enable tone dialing result code form long short 0 short extented result code formats 0 CONNECT with DTE speed 1 CONNECT with CARRIER PROTOCOL and DTE speed 2 CONNECT with DCE speed result code formats call progress options 0 CONNECT without speed message blind dial no busy tone CONNECT with speed message blind dial no busy tone 2 CONNECT with speed message wait for dial tone no busy tone CONNECT with speed message blind dial check busy tone 4 CONNECT with speed message wait for dial tone check busy tone load user profile n n 0 9 0 load user profile 0 n load user profile n DCD control 0 DCD forced on 1 DCD normal 2 V 13 HDX 3 V 23HDX DTR on to off actions 0 ignore 1 recall command mode 2 disconnect 3 reset modem AT amp Fn load factory profile n n 0 9 CHAPTER 5 INSTRUCTION SETS Function Description guard tone options 0 disabled 1 550 Hz 2 1800 Hz AT amp Kn DTE flow control options or 0 n
49. l HArdware CTS RTS CTS only Software X ON X OFF e Dial Command Extended AT and ITU T V 25bis command set CHAPTER 1 TAINET MODEM INTRODUCTION Table 1 1A Modem operating mode 4 wires 2wires L L or D L Operating Mode Carrier Symbol Constellation rate points 33600 Table 1 1c Table 1 1c 4 to 1024 31200 pee on the combination of FERAN data rate 26400 symbol rate and 24000 constellation 21600 expansion 19200 chosen 16800 14400 12000 9600 7200 4800 2400 14400 T TCM TCM QAM TCM QAM gam 12002400 oo 1 v22 10 Desk 12002400 60m 4 FSK N A FSK 300 N A BELL 212A 1200 pesk 12002400 60m 4 FSK 300 NIA CHAPTER 1 TAINET MODEM INTRODUCTION Table 1 1B V 34 Symbol Rate and Carrier Frequency Symbol Rate Baud Low Carrier Hz High Carrier Hz 2400 1600 1800 3000 1800 2000 3200 1829 1920 3429 1959 1959 e Transmit Level Lease Line 0 31 dBm 1 dB stepadjustable Dial Line 0 15 dBm 1 dB step adjustable e Line requirement 4 2 wires L L or D L e Line Impedenance Balance 600Q 10 Yo e Return Loss gt 20 dB 300 3400 Hz e Longitude Balance gt 60 dB e Dial Line Characteristics Maximum Current 120 mA Holding Resistance 50 220 Q Holding Current 25 110mA Ring Detect Range ON gt 27 Vrms OFF lt 13 Vrms Ring Detect Frequency 16 50 Hz DTMF Characteristics f O P Lowband 8 1 dBm O P Highband 6 1 dBm Frequency T
50. le still exists please follow the procedures below 1 Power Unit e Make sure you get a proper power source If no indicator is lighted probably the problem is the power unit e Check the power fuse if it is broken replace it 2 RS 232 Interface e Do the AL local analog loopback test feed some data into the modem and check if they were returned correctly e Please make sure the interface is connected firmly also check if the cable is in good condition 6 5 Return Procedures We suggest the individuals who hold a malfunctioned the TAINET Network Series Modem would contact with your local representative or distributor of Tainet or just directly access our customer service department as soon as possible in order not to cause catastrophe You may find the contact address and phone number in the cover sheet of this manual 58 APPENDIX 1 T 336Cx S REGISTER TABLE APPENDIX 1 T 336Cx S REGISTER TABLE No SO SI S2 S3 S4 S5 S6 S7 S8 S9 S10 S11 S12 S13 S14 No 59 Default 1 0 43 13 10 8 2 45 2 6 15 95 14 19 00001010 Default Unit times times decimal decimal decimal decimal second second second 100ms 1 1s ms 100 ms binary binary Unit Function Description Auto answer Ring Count Current Ring Count read only Escape Char CR Char LF Char Backspace Char Pause Before Blind Dial Wait for Carrier Time Pause for Comma Carrier Validation Time Lost Ca
51. mand Description AT Nn Select error correction and data compression function for async mode only This setting is ineffective in sync mode It will automatically become direct mode regardless of setting made once the link established AT NO with DTE speed conversion only Note that the flow control function must be active ATANI disable error correction data compression and DTE speed conversion modem speed DTE speed AT N2 Link con be established only when MNP function is enabled on the remote modem AT N3 Automatically negotiate V42 MNP level with the remote modem The negotiation sequence is V42bis V42 MNP5 MNP4 NORMAL AT N4 Link can be established only when V42 function is enabled on the remote modem AT N5 Negotiate V42 level with the remote modem The sequence is V42bis V42 NOMAL AT N6 VAutomatically negotiate V42 MNP level with the remote modem The negotiation sequence is V42bis V42 MNP5 MMP4 AT N7 Negotiate MNP level with the remote modem The sequence is MNP5 MNP4 NORMAL ATWn Select the extended CONNECT result code ATWO with DTE speed ATW1 with CARRIER PROTOCOL and DTE speed ATW2 with DCE speed ATS28 n Disconnect method for V34 V32bis V32 bit3 2 Disconnect immediately Send clear down sequence before disconnection default Reset modem after disconnection this option is effective only under ANS mode password to authenticate dial in modem Disable Login Check function With this s
52. n PROTOCOL setting in both modems should be identical 44 CHAPTER 4 GENERAL INFORMATION AND FEATURES 29 13 e Dynamic Password Call Back Control Code as gt lt will not take effect during Login check will be treated as part of Password There s no Call Back function under leased line mode f Password Security by Pass through 4 18 Intelligent Dial Polling 1 Settings When under Dial Modifiers setting use symbol for intelligent dial polling instead but is still wait for quiet answer silence cc 2 Operations If a symbol included in the Telephone Number 0 9 also abnormal disconnection i e jumping back to Idle before connecting occurred exception when Originate user press the VO DA button then dialing will be proceeded from the telephone number with a symbol and stop at the one without a symbol For instant Tel 0 12345678 Tel 1 23456789 Tel 2 34567890 If dialing starts from 0 it will automatically dial from 0 1 to 2 and stops at 2 Note if user has set Dial To Dial function to On then the dialing will keep dialing 2 Also reminds that a If user is using ATDTxxxx command to dial then it will start the dial polling from Telephone Number 0 b If the setting of DTR is DTR off to on 108 1 then the symbol function needs to be set included in 0 in order to start the dial polling function af
53. n binary form After selecting the form press Enter to starting editing S register shown in the following format xx Use left key right key and enter key to select the S register to be edited AAA Use left key right key and enter key to edit the value of the selected S register in decimal form OOOOOOOD Use lift right and enter key to edit the value of the selected S register in binary form To discard editing press exit key CHAPTER 4 GENERAL INFORMATION AND FEATURES CHAPTER 4 GENERAL INFORMATION AND FEATURES CONTENT 4 1 Preview 4 2 Dieal Line VS Leased Line 4 3 2W 4W Leased Line 4 4 Originate Mode VS Answer Mode 4 5 Synchronous VS Asynchronous 4 6 Error Correction And Data Compression 4 7 Configuration Profile Set up 4 8 Remote Access 4 9 Multi standard Handshake 4 10 Auto Dial Back Up 4 11 Auto Fallback And Fall Forward 4 12 Line Status Monitoring 4 13 B E R Test 4 14 Intelligent Dial 4 15 Front Panel Lock And Password Protect 4 16 ITU T V 13 V 23 Simulated Carrier Control in Half Duplex 4 17 Password and Call Back Functions 4 18 Intelligent Dial Polling 4 19 G3 Fax Send Receive 37 CHAPTER 4 GENERAL INFORMATION AND FEATURES CHAPTER 4 GENERAL INFORMATION AND FEATURES 4 1 Preview In order to help you to get familiar with your TAINET Network Series Modem this chapter introduces you some common applications For most applications the materials of this chapter will be enough 4 2 Dial Line VS
54. noise ratio S N Ratio 35 dB 4 Received frequency shift F Shift 0 2 Hz 5 Far end frequency shift F F Shift 1 7 Hz 6 Round trip delay Delay 560 ms 42 CHAPTER 4 GENERAL INFORMATION AND FEATURES 7 Phase jitter P J 1 Degree 8 Far end echo level F Echo 40 dB 9 Terminal mode DTE 19200 ASY 10 10 Retrain count Retrains 1 The parameters above can be found in STATUS menu 4 13 B E R Test In addition to the parameters stated in the previous section the TAINET Network Series Modem also offers bit error rate test without any extra test instruments Before using the BER test you have to build a connection then enter TEST menu set BER Test to be ON select Error count Note that if you want to do this test with both modems you need to do the setting described above with both modems During test you may press gt or lt key to send some error codes and observe whether the other modem received them or not The number of error bits for each issue is from 2 to 5 At the beginning of the test you may press ENTER to clear Error Count Wait a period you may get B E R by dividing error count by total transmitted bits There are one test pattern say 511 you may choose from The selection can be done at BER TEST under Test menu Note that the settings of both modems should be consistent You may execute this test even no one is at the remote site It can be done by utilizing remote digital lo
55. o flow control AT Qn 1 XON XOFF flow control 2 CTS only flow control 3 RTS CTS flow control AT amp Ln line type selections 0 dial line 1 2 wired leased line 2 4 wired leased line AT amp Mn data format options or AT amp Qn 0 async data mode 1 sync data mode AT amp Pn dial pulse MAKE BREAK ratio 0 USA 39 61 1 UK 33 67 AT amp Rn RTS CTS options 0 RTS normal 1 RTS forced on AT amp Sn DSR control 0 DSR forced on 1 DSR on after connect AT amp Tn selftest commands 0 clear all test LAL test DL test RDL grant enable RDL grant disable RDL test RDL TP test 8 LAL TP test 10 TP on AT amp Vn view active config user profiles tel numbers 0 view current active profile n view user profile n n 1 9 AT8Wn save to user profile n n 0to9 AT amp Xn sync tx clock source options 0 internal clock 1 external clock 2 slave loopback clock 49 CHAPTER 5 INSTRUCTION SETS AT amp Yn powerup user profile n n 0 9 0 load user profile 0 on power up n load user profile n on power up AT amp Zn view store telephone number n n 0 9 n 0 9 the selected telephone number AT amp Zn view tel number n AT amp Zn string store the string to tel number n ATUn DTE DCE speed convert on off 0 enable DTE DCE speed convert 1 disable DTE DCE speed convert AT Nn protocol type options 0 normal mode driret mode MNP reliable mode auto reliable mode
56. o use this function you must set leased To Dial and Dial To Leased to be AUTO or MANUAL under LINE SETUP menu also fill up Backup Tel 1 and recovery time 4 11 Auto Fallback And Fall Forward When auto fallback amp fall forward is enabled in V 34 or V 32bis mode the modem will automatically initial a V 34 or V 32bis rate renegotiation when the line condition changes so that the optimum available data rate is always select with minimal interruption to user data To use this function the FF FB control under CONFIG MODEM menu must set to be on 4 12 Line Status Monitoring In order to let users manage transmission conditions the TAINET Network Series Modem provides a signal quality displayed at right lower corner of the screen It ranges from 0 to 9 The following shows the relationship between the displayed number and bit error rate BER 9 lt 10 9 8 lt 10 8 7 lt 10 7 6 lt 10 6 5 lt 10 5 4 lt 10 4 3 lt 10 3 2 lt 10 2 1 lt 10 1 0 NO Connect Basically 10 5 to 10 6 is the basic required bit error rate If this condition is not achievable leased line users should report to telephone company however it is better for dial line users to try the dial again There are some real time line condition information which may help you judge the line quality Examples 1 Transmitted signal level Tx level 10 dBm 2 Received signal level Rx level 25 dBm 3 Signal to
57. olerance lt 1 TONE Duration and Spacing 95 ms adjustable Pulse Per Sec 10 0 5 PPS Make Break Ratio 33 67 39 61 3 e Auto Answer V 32bis V 32 V 22bis V 22 comply with ITU T V 25 amp V 25bis V 34 Comply with ITU T V 8 V 25 V 25bis Answer Tone 2100 15Hz e Calling Tone Comply with ITU T V 8 V 25 e Receive Range 12 44 dBm 2 35 dBm e Dynamic Range 0 44 dBm e Equalization Automatic Adaptive Equalizer e Frequency Shift Compensation cancel at least of 7Hz offset CHAPTER 1 TAINET MODEM INTRODUCTION Far end Echo Coverage Maximum 1 2 seconds Scrambler amp Descrambler Comply with ITU T V 34 V 32bis V 32 V 22bis V 22 Data And Control Signal Output Voltage 6 12 V ITU T V 28 Input Voltage 3 25 V Output Impedance 3300 Input Impedance 3000 7000 Q Tx Clock Source Internal External Loopback Freq Tolerance 30 01 Duty Cycle 5041 Test Features V 54 V 52 LAL DL RDL Test Patterns 511 Power Requirement 90 265 VAC Auto Range 47 63 Hz DC Power Input 36 72 VDC option Chassis type Operating Temperature 0 C 50 C Storage Temperature 25 C 70 C Relative Humidity a 95 Yo non condensing Physical Size Stand alone gt W 180mm H 48mm D 262mm Weight 0 9kg Rack mount card gt W 220mm H 26mm D 328mm Weight 0 6kg Rack mount shelf gt W 19 H 6RU D 380mm Weight 8kg Full shelf Equipped Weight 16kg
58. ons bit 1 0 connect message display 00 ATWO CONNECT with DTE speed 01 ATW1 CONNECT with CARRIER PROTOCOL and COMPRESSION 10 ATW2 CONNECT with DCE speed 11 reserved bit 2 3 4 5 reserved bit 7 6 DTMF level selection Low Band High Band 00 8 6 dBm 01 10 8 dBm 10 12 11 dBm 11 11 9 dBm No Default Unit Function Description 63 APPENDIX 1 T 336Cx S REGISTER TABLE S42 00000010 S43 00000000 S44 S45 S46 S47 S48 S49 S50 00000000 S51 00000011 No Default S52 0 64 binary Bit Mapped Options bit 0 reserved bit 1 0 receive power drop control off receive power drop control on bit 2 0 enable V 34 asymmetrical rate 1 disable V 34 asymmetrical rate bit 3 0 disable dial to dial 1 enable dial to dial bit 7 6 5 4 0000 1010 Pre Emphasis Filter Suggestions Number 0 A 1011 1111 Ignore Pre Emphasis Filter binary Fast Connect Control bit 3 2 1 0 Answer tone length 100ms time base Oms 1500ms bit 4 Fast connect on off 1 0 bit 7 6 5 reserved Reserved Reserved Reserved Reserved Reserved Reserved binary Bit Mapped Options bit 1 0 FAX DATA Mode Selection 00 DATA mode 01 reserved 10 reserved 11 reserved bit 2 reserved bit 7 6 5 4 3 reserved binary Bit Mapped Options bit 1 0 flow control 00 AT Q0 AT amp KO no flow control 01 AT QI AT amp K1 XON XOFF flow control 10 AT Q2 AT amp K2 CTS only flow control 11 AT Q3
59. opback RDL which makes remote modem loopback its received data To start it activate RDL in Test menu then execute BER test stated above Beware that error codes generated by local modem will be received by itself Hence the error count you get is the sum of that of transmitted and received routes bilateral You may judge whether the modem is good or not by operating local analog loopback then execute BER test No matter how long you execute this test the error count should be 0 4 14 Intelligent Dial There are some data terminal equipment such as multiplexes controllers and synchronous terminals can t issue AT commands to dial The modem offers you a very convenient way to dial by means of operating front panel In addition to ten set phone number it provides you a 108 1 auto dial function which dial pre determined number when you turn the modem on or when DTR is turned on off to on transition 4 15 Front Panel Lock and Password Protect In order to prevent from the operation of unauthorized persons we offer you this function After you set Front Lock under PROFILE menu to be Lock even the front panel keys are still effective all the operations affecting transmission are not allowed You only may observe the setting and monitor the line conditions To release the lock you need to enter a password The following is the table of panel keys EXIT X ENTER E HOME V gt ma
60. ous 10 bits in total bit length DTE 14400 SYN means 14400 bps synchronous Total retrain count From the total retrain count you will find the total times of line interference occurred This value will not be cleared automatically unless pressing the ENTER key or power off CHAPTER 3 FRONT PANEL AND MENU TREE MANU RETRAIN ATO2 Force Modem redo adapting RX BAUD XXXX AT S Indication of the signaling rate of received signal For examples RX Baud 3429 means the switching speed or number of transitions is 3429 however one baud can be made to represent more than one bit per second This value is only available when operating on V 34 TX BAUD XXXX AT S Indication of the signaling rate of transmitted signal This value is only available when operating on V 34 RX FREQ XXXXHz AT S Indication of the carrier frequency of received signal For examples RX Freq 1959Hz means the unique frequency used to to carry data is 1959 Hz This value is only available when operating on V 34 TX FREQ XXXXHz AT S Indication of the carrier frequency of transmitted signal This value is only available when operating on V 34 TX SPEED AT S Indication of the DCE speed of transmission XXXXbps RX SPEED AT S Indication of the DCE speed of receiving XXXXbps TX POWEROFF AT S Indication of a reduction of transmit power level For XdB examples TX PowerOff 6dB means the transmit power level is requested to reduce 6 dB by th
61. receive signal level S N ratio EQM eye quality monitoring signal quality frequency shift delay echo retrain count phase jitter Tx Rx baud rate Tx Rx carrier frequency Tx Rx DCE speed TX power back off etc Front panel lock and password protect features prevents from the operation of unauthorized person Enable remote configuration through secondary channel V 138 V 23 simulated carrier control for half duplex application 2 wires or 4wires automatic or manual dial back up and restore CHAPTER 1 TAINET MODEM INTRODUCTION 1 2 Technical Specifications T 336Cx Nx NDx fully comply with ITU T recommendations V 34 V 32bis V 32 V 22bis V 22 V 21 V 23 V 24 V 26bis V 28 V 25 V 25bis V 52 V 54 V 42 V 42bis V 8 and BELL 212A 103 operating standards e Modulation type Refer to table 1 1A 1 1B e Clock tolerance 1 Synchronous 0 01 2 Asynchronous Basic range 1 to 2 5 Extended overspeed range 2 3 to 2 5 e DTE speed 1 Synchronous 33600 31200 28800 26400 24000 21600 19200 16800 14400 12000 9600 7200 4800 2400 1200 bps 2 Asynchronous 115200 76800 57600 38400 33600 32000 3 1200 28800 26400 24000 2 1600 19200 16800 14400 12000 9600 7200 4800 3600 2400 1200 600 300 bps with speed conversion Total bit length 8 9 10 11 bits Parity bit odd even none Stop bit 1 1 5 2 bits e Error Correction MNP 4 ITU T V 42 e Data Compression MNP 5 ITU T V 42bis e Flow Contro
62. rly grounded as described in article 250 of the National Electrical Code NEC handbook The following procedure outlines some common practices which can minimize the risk of damage to computer equipment from electrical surges Verify that a good copper wire of the appropriate gauge as described in Tables 250 94 95 of the NEC Handbook is permanently connected between the electrical service panel in the building and a proper grounding device such as 1 A ground rod buried outside the building at least 8 feet 2 44 meters deep in the earth Several ground rods connected together buried outside the building at least 8 feet 2 44 meters deep in the earth 10 CHAPTER 2 INSTALLATION 2 If you are unsure whether the electrical service in your building is properly grounded have it examined by your municipal electrical inspector 3 Install a surge protector between the modem and AC power outlet Any additional computer equipment you have connected to the modem directly or through another device such as a terminal or printer should also be plugged into the same surge protector Make sure that the surge protector is properly rated for the devices you have connected to it 4 Call your telephone company and ask them if your telephone line is equipped with a circuit surge protector 5 If you are operating the modem in an area where the risk of electrical surges form lightning is high disconnect the modem form the telephone line at t
63. rrier Detect Time 1 sec unit for V34 V32bis V32 0 1 sec unit for V22bis V22 DTMF Tone Duration Guard Time Escape Sequence Pause Bit Mapped Options set clear bit 4 3 2 1 0 DTE Speed 0 300 bps 1 600 bps 2 1200 bps 3 1800 bps 4 2400 bps 5 3600 bps 6 4800 bps 7 7200 bps 8 9600 bps 9 12000 bps 10 14400 bps 11 16800 bps 12 19200 bps 13 21600 bps 14 2400 bps 15 26400 bps 16 28800 bps 17 32000 bps 18 38400 bps 19 57600 bps 20 76800 bps 21 115200 bps 22 31200 bps 23 33600 bps bit 7 6 5 reserved Bit Mapped Options set clear bit 0 0 AT CO calling tone off 1 AT Cl calling tone on bit 1 0 ATEO echo off ATEI echo on bit 2 0 ATQO response on 1 ATQI response off bit 3 0 ATVO response code ATVI response word bit 4 reserved bit 5 0 ATT Tone Dial 1 ATP Pulse Dial Function Description APPENDIX 1 T 336Cx S REGISTER TABLE S15 S16 S17 S18 S19 S20 S21 60 01000000 0 00011100 00000101 Default binary minute binary binary Unit bit 6 reserved bit 7 0 ATA Answer 1 ATD Originate reserved Bit Mapped Options set clear bit 0 0 ATSTO Test Pattern off 1 AT amp T10 amp T7 amp T8 Test Pattern on bit 1 RDL off l RDL on bit 2 0 AT amp TO LAL off 1 AT amp T1 T8 LAL on bit 3 0 AT amp TO LDL off AT amp T3 LDL on bit 4 0 AT amp TO RDL off 1 AT amp T6 T7 RDL on bit 5 reserv
64. ser Profile 0 9 Front Lock ATS29 n Unlock bit4 Lock Password edit Input ___ Power up AT amp Yn User Profile 0 9 Initial 34 AT amp F10 Description This machine provides 20 groups of load configuration profile Among them 10 groups configuration profile which cover the most required applications for normal use The other 10 groups are set by the user which can be revised by the user before filing for use User defined load profile 0 9 Through this operation required settings can be made for the next operation when the modem is power on Load factory profile 0 9 Async dial line AT command Auto reliable mode V34 Adapt this mode is most applicable to BBS networks Async dial line AT command direct mode and V34 Adapt this is a typical operating mode for Hayes compatible modem Sync dial line V 25bis command V34 Adapt this mode is applicable to IBM AS 400 series sync dial networks Async 2W leased line answer applicable to the most of the async non compressed 2 wire leased line Async 2W leased line originate applicable to the most of the Async non compressed 2 wire leased line Sync 2W leased answer applicable to the most of the Sync 2 wire leased line Sync 2W leased line originate applicable to the most of the Sync 2 wire leased line Sync 4W leased answer applicable to the most of the Sync 4 wire leased line Sync 4W leased line originate applicable
65. telephone company to determine the maximum REN to your calling area If your equipment causes harm to the telephone network the telephone company may discontinue your service temporarily If possible they will notify you in advance But the advance notice isn t practical you will be notified as soon as possible You will be informed of your right to file a complaint with the FCC Your telephone company may make changes in its facilities equipment operations or procedures that could affect the proper functioning of your equipment If they do you will be notified in advance to give you an opportunity to maintain uninterrupted telephone service If you experience trouble with this telephone equipment please contact the following address and phone number for information on obtaining service or repairs The telephone company may ask that you disconnect this equipment from the network until the problem has been corrected or until you are sure that the equipment is not malfunctioning This equipment may not be used on coin service provided by the telephone company Connection to party lines is subject to state tariffs COMPANY SUMMIT MICRO DESIGN INC ADDRESS 485 MACARA AVE SUITE 901 SUNNYVALE CA 94086 USA TEL NO 408 739 6348 CHAPTER 1 TAINET MODEM INTRODUCTION Chapter 1 TAINET MODEM INTRODUCTION 1 1 Description 1 2 Technical Specifications 1 3 Ordering Information CHAPTER 1 TAINET MODEM INTRODUCTION CHAPTER
66. ter the initial dialing c If the setting is Dial to Dial on then the symbol function needs to be set included in the Backup Tel in order to start the dial polling function after the initial dialing d If the dial polling number followed by an Empty phone number then the dialing will cycle back to 0 However if the Tel 0 is an empty number then the dial polling will terminate e When dial polling to 9 or 5 when the Country Code is Beijing Tainet it will return back to 0 f When during the Dial Backup Leased to Dial then the function will not be working g The dial polling will terminate when a connection has been made h Before the connection user at Originate can press the VO DA key to terminate the dial polling 45 CHAPTER 5 INSTRUCTION SETS 46 CONTENT 5 1 AT Command Set 5 2 Dial Modifiers 5 3 Result Codes 5 4 V 25bis Auto Call Unit CHAPTER 5 INSTRUCTION SETS CHAPTER 5 INSTRUCTION SETS CHAPTER 5 INSTRUCTION SETS 5 1 AT Command Set Table 5 1 AT Command Set echo on off 0 echo off 1 echo on hang on off 0 on hook 1 off hook modem identification command report product code ROM checksum verify ROM checksum Report ROM components modem capabilities and version Country Code pump controller CS pump DSP CS CTL SPX Version OK speak volume control 0 Low 1 Medium 2 High speak contro
67. the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This booklet is available from the US government Printing Office Washington DC 20402 Stock NO 004 000 00345 4 The shielded RS 232 cable is to be used in order to ensure compliance with FCC Part 15 and it is the responsibility of the user to provide and use shielded RS 232 cable from MODEM to personal computer CAUTION Any changes of modifications not expressly approved by the grantee of this device could void the user s authority to operate the equipment 111 FCC REQUIREMENTS This equipment complies with Part 68 of the FCC Rules On the base unit of this equipment is a label that contains among other information the FCC Registration Number and Ringer Equivalence Number REN for this equipment IF REQUESTED THIS INFORMATION MUST BE GIVEN TO THE TELEPHONE COMPANY The REN is useful to determine the quantity of devices you may connect to your telephone line and still have all of those devices ring when your telephone number is called In most but not all areas the sum of the REN s of all devices connected to one line should not exceed five 5 0 To be certain of the number of devices you may connect to your line as determined by the REN you should contact your local
68. tivated by DTR provided by DTE default value 1 times Turn off the auto answer function An auto answer will be given when bell rings 1 255 times Enable detecting of busy tone or dial tone to proceed dialing and showing the connection Don t care any tone and do not show line connection speed Don t care any tone and show the line connection speed Don t detect busy tone but show the line connection speed Don t care dial tone but show the line connection speed Do care dial tone busy tone and show the extended result code default Pause time between auto redial Redial Immediately Set up redial time Default 2 second Select dial type Tone DTMF dialing mode Pulse dialing mode Monitoring speaker switch control Keep speaker always off Speaker turn on until DCD ON then turn off default Keep speaker always on Turn on speaker after dialing is completed and then detect until to find out carrier and then turn off speaker Speaker volume control Set speaker volume to low Set to medium default Set to high CHAPTER 3 FRONT PANEL AND MENU TREE 3 5 3 Item Name Protocol Type Normal Direct Reliant MNP Auto Reliant LAPM LAPM Normal LAPM MNP MNP Normal Connect Code DTE Speed DTE EC DCE DCE Speed Discon method Immediate With clear down Modem reset Login Check Disable 0 49 ALL By NMS Send Password Off 0 9 26 PROTOCOL MENU Com