RC602-GE (A) remote management 1000M Ethernet media

image

Contents

1. Ambience Operating temperature 0 45 C Humidity 5 90 non condensing 7 Power supply requirement Single slot chassis 220V 50Hz AC or 48V DC 16 slot chassis 220V 50Hz AC or 48V DC 8 Dimensions Single slot chassis 155 W x 39 H x 120mm D 16 slot chassis 442 W x 130 5 H x 350mm D RA SECOM Raisecom Technology Co Ltd 6 Dip Switch Functions of RC602 GE A series copper to fiber media converter can be configured by the function configuration DIP switches The modular media converter has function configuration DIP switches SW2 and function configuration DIP switches of standalone media converter is SW2 which is on the rear panel Besides modular media converter also has a type configuration switch SW1 6 1 Explanation of function configuration DIP switch SW2 is a 8 bit DIP switch and the 8 bits are optical to electrical fault pass through enable disable electrical to optical fault pass through enable disable optical port RX to TX fault pass through enable disable and remote management enable disable Please refer to the following table for details Switch Function Status Explanation OFF Optical port RX to TX fault pass through disabled SW2 1 Fault return ON Optical port RX to TX fault pass through enabled SW2 2 Reserved SW2 3 Reserved SW2 4 Reserved FF Enabl SW2 5 Remote O di e management ON Disable OFF RC602 GE A Master ON RC602 GE A
2. Device specifications Dimension HxWxD 25mmx76mmx170mm Optical interface SC PC SC PC Work temperature C 0 45 Storage temperature C 40 80 Power consumption W Typical value 4W Humidity 5 90 non condensing 2 2 Optical interface specifications Wave Tx Output s Cable Attenuatio Rx Saturation Model Interface Length Power En Length n nm dBm Km dB Km RC602 GE A M DSC 850 10 3 lt 15 0 0 55 3 RC602 GE A S1 DSC 1310 10 3 lt 23 0 25 0 5 RC602 GE A S2 DSC 1550 lt 20 10 60 0 25 a 2 DFB 3 RC602 GE A S3 DSC 1550 lt 30 APD 25 100 0 25 Me 2 DFB RC602 GE A SS1 4 SC 1310 10 3 lt 20 0 20 0 5 RC602 GE A SS1 5 SC 1550 10 3 lt 20 0 20 0 5 RA SECOM Raisecom Technology Co Ltd 3 Front view and indicators 3 1 Front view of RC602 GE A LNK TX RX ACTLNK e Siam sims TX RMD PWR RX The explanation of RC602 GE indicators Interfa Indicator Name Indicat Explanation of Indicator Optica Optical RX LNK ON optical RX link works properly Indicator OFF optical RX link is abnormal interfa ce Indicat Indicator Name Explanation of Indicator Interfa or ce Remote cd management RMD Fixed on remote GEES E managed ao Fixed off remote device is not managed indicator Electrical link ON electrical port works properly Elect
3. GE A SS15 Master RC602 GE A SS13 Slave 4 2 Connect MC with Other Devices Electrical Port RC602 GE A series copper to fiber media converters have the function of MID MIDX auto sensing so they can connect with other devices through straight though cable or crossover cable Media Other device Connection type of RJ45 port converter Media converter Switch Straight through crossover Media converter HUB Straight through crossover Media converter Router Crossover straight through Media converter NIC Crossover straight through 4 3 Working Mode Configuration Electrical Port Electrical port of RC602 GE A series copper to fiber media converter has the ability of auto negotiation and works in 1000M full duplex mode cannot work in 1000M half duplex mode And the electrical port of other device should enable auto negotiation to make sure of normal communication RA SECOM Raisecom Technology Co Ltd 4 4 Connecting MC with Other Devices optical port The 1 2 3 4 following conditions must be satisfied The same wavelength single strand dual wavelength MC is not included The same data rate Matched optical power Gigabit Ethernet protocol IEEE 802 3z Gigabit Ethernet Optical port is forced to work in 1000M full duplex and auto negotiation function is disabled RA SECOM Raisecom Technology Co Ltd 5 Installation amp preparation 1 Make sure t
4. SECOM Raisecom Technology Co Ltd 1 Overview 1 1 Introduction RC602 GE is 1000M Ethernet media converter that supports both local and remote management and the longest transmission distance is 100km With NView iEMS network management local RC602 GE can be wholly controlled and configured 1 2 Features 4 RC602 GE A has Master and Slave working mode Master is working in central site Slave is working in remote site The working mode can be changed through the DIP switch Transport Ethernet data at rate of 1000M transparently Requirement of different transmission distance and different wavelength can be satisfied Flexible network fault management function which provides optical port RX to TX fault pass through Optical to electrical fault pass through and Electrical to optical fault pass through to satisfy different customers needs 1 3 Ordering information RC602 GE A central remote module 1000Mbps multimode 0 550m RJ45 DSC M RC602 GE A S1 central remote module 1000Mbps singlemode 0 25km RJ45 DSC RC602 GE A S2 central remote module 1000Mbps singlemode 10 60km RJ45 DSC RC602 GE A S3 central remote module 1000Mbps singlemode 25 120km RJ45 DSC remote module 1000Mbps singlemode single strand fiber 0 25km RJ45 SC central module 1000Mbps singlemode single strand fiber 0 25km RJ45 SC RC602 GE A SS13 RC602 GE A SS15 RA SECOM Raisecom Technology Co Ltd 2 Parameters 2 1
5. Slave Optical to electrical fault pass through SW2 6 Master slave tical to electri Optical to electric OFF al disabled SW2 7 fault pass through Optical to electrical fault pass through i ON enable disable enabled Electrical to optica OFF Electrical to optical fault pass through SW2 8 disabled fault pass through Electrical to optical fault pass through ON enable disable enabled SW2 ex factory setting 1 2 3 4 5 6 7 8 ON OF r E E E E EE E E Note SW2 6 ex factory setting is OFF RC602 GE A Master 11 RA SECOM Raisecom Technology Co Ltd 6 2 Introduction of type configuration DIP switches SW1 is used for setting up the type of device Please refer to the following table for details SW1 1 SW1 2 SW1 3 SW1 4 Module type ON ON ON ON RC602 GE A M ON ON ON OFF RC602 GE A S1 ON ON OFF ON RC602 GE A S2 ON ON OFF OFF RC602 GE A S3 ON OFF ON ON RC602 GE A SS13 ON OFF ON OFF RC602 GE A SS15 Note Customers are not permitted change the state of type configuration DIP switches SW1 RA SECOM 7 Network management 7 1 View the module status Raisecom Technology Co Ltd The RC602 GE A Master status information can be viewed controlled and configured through network management software RC602 GE A Slave can be controlled and configured through RC602 GE A Master Available status
6. pass through optical to electrical port fault pass through electrical to optical port fault pass through etc 7 3 Reset the module Local module can be reset through Reset module command After reboot the working mode and status will remain the same as that before reboot RA SECOM Raisecom Technology Co Ltd 8 Q amp A Fault phenomenon Resolve methods Optical LNK indicator turns off Check whether the input optical power of optical interface is normal There is packet loss and optical connection breaks off sometimes First check whether the input optical power of optical interface is normal if it is normal check if the rate and duplex mode of the two sides match each other If not set the relative DIP switches Network management is not available Make sure that the EMS version is 1 15 build2 6 6 0 or higher and MCU chip is secured to the main board Optical interface Link Down Make sure both sides are powered on and fiber is connected correctly and when RC602 GE works in pairs the Rx to Tx fault pass through function is not enabled at both sides at the same time Electrical interface Link Down Make sure that UTP complies with 568 a and 568b standards otherwise they cannot communicate normally Make sure both side devices are powered on and the electrical port is not shutdown through network management When connect with other factory device the LNK indicator is
7. steady ON but the two devices cannot communicate normally Make sure that the optical port of other factory device works in 1000M full duplex When the remote device can not be checked Firstly please check SW2 5 to make sure if it is enable then please check SW2 6 if it is slave setting RA SECOM Raisecom Technology Co Ltd BROADBAND to RAISECOM 2006 Raisecom Technology Co Ltd All trademarks are the property of their respective owners Technical information may be subject to change without prior notification
8. RA SECOM RC602 GE A remote management 1000M Ethernet media converter User Manual Raisecom Technologies Co Ltd Jan 2006 RA SECOM A A A diam Raisecom Technology Co Ltd Cautions Please read the following notices carefully before installing and using the device Raisecom does not respond to any loss that caused by violating safety notice RC602 GE series provide optical port and the Tx laser may damage your eyes So do not look into the optical port and if the optical port is not used please insert the plug RC602 GE series are integrated devices that have precise elements please avoid violent shakes and impacts and do not disassemble or maintain the devices yourself If it is required please do it under the guide of our technical staff following in the steps of anti static Please contact us if there is any need There must be grounding protection for the sake of safety do not disassemble the device yourself we regard it as you waiver your rights of repair guarantee RA SECOM Raisecom Technology Co Ltd Content Ns OVERVIEW Srs ce tee cette AO a nena a PS a radar 3 Vel Introduction sisesta aaa 3 1 2 Feature Snerre aa isis ee eee E a EEEa 3 1 3 Ordering information ccccccceeeceeseeeeeeeeeeeeceeceeeeeeeeeeesesneneeeeeeeeeeeeneaas 3 2 ParamelerS ca cere ees tosa a dig Rie a e a a na eau dade datas 4 2 1 Device Specifications c cccccccceececcecceceeeeeees
9. eneaeeeeeeeeseseeeeneeeeeeeeeeteeeees 4 2 2 Optical interface specifications erra 4 3 Front view and indicators cccccccceecceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeereeeeeeeeeeeeeeeeeeeegs 5 3 1 Front view of RC602 GE A erra 5 3 2 Front view 16 slot chassis 0 eee eee 6 4 Connection Configuration c cccccceeeeeeceecceeeceeeeeeeceneeeeeeeeesesenccaeeeeeeeeeeteegeas 7 4 1 Interconnecting Devices ccceceeceeeeceeeeeeeceeceaeeeeeeeeeesenceeeeeeeeeeeeenees 7 4 2 Connect MC with Other Devices Electrical Port cccssscseeeeeeees 7 4 3 Working Mode Configuration Electrical Port iii 7 4 4 Connecting MC with Other Devices optical port cece 8 5 Installation amp preparation cccccccecceeeceeceeeeeeeceecceeeeeeeeeeseeeeeeaeeeeeeeeseeeseseeeees 9 O DIPAS WICK acisini tive denned sede a eiaa aa delas aaa a Ea da ada deme 11 6 1 Explanation of function configuration DIP switch 11 6 2 Introduction of type configuration DIP switches 12 7 Network management erica rear 13 7 1 View the module status 000 000 secretas 13 7 2 Configure the module seen 14 7 3 Reset the module llll nene 14 Bi QUA uuciaataaa Crafts eeaeed E a De Gean GES EEE Ped tuni a esa gana d o 15 RA
10. hat fiber optical media matches the media converter RC602 GE A M must use multi mode optical fiber and the connector should be DSC RC602 GE A S1 2 3 must use single mode optical fiber and the connector should be DSC Single mode optical interface of RC602 GE A SS13 5 must use single mode optical fiber medium and the connector should be SC PC 2 Fiber type Fiber for multi mode optical interface 62 5 125um multi mode optical fiber or 50 125um multi mode optical fiber Fiber for single mode optical interface 9 125um single mode optical fiber 3 Electrical interface Connecting media converter with Cat 5 twisted pair which should not be longer than 100m Refer to 4 2 Connect MC with Other Devices Electrical Port in Chapter 2 for details 4 Installation of chassis refer to the following figure 19 standard chassis 3 oo ooo seres SS O Note Brackets used to fix the chassis are in the accessory box If you use the bracket s rear holes to attach brackets to the chassis there will be 3cm space between chassis front panel and cabinet front panel and if you use the bracket s front holes the front panel and the rack will be at the same level vertically 5 Install the DC power supply There are three connectors of DC power supply 48V Ground OV which must be connected to 48 power supply cable protection ground and OV power supply cable respectively RA SECOM Raisecom Technology Co Ltd 6
11. information of RC602 GE A command is return Numb Status name control and Value Controllable features er configuration items RC602 GE REV A Mast 1 Module type a ai Not controllable 2 Remote management Enable disable Controllable Optical to electrical t Bye ee Enable disable Controllable fault pass through Electrical to optical fault 4 alata deel Enable disable Controllable pass through 5 Electrical port Link status Up Down Not controllable 6 Electrical port control Open close Controllable 7 Electrical port FP control Open close Not controllable 8 Optical module type M S1 S2 S3 SS15 Not controllable 9 Optical port Link status Up Down Not controllable 10 Optical port control Open close Controllable 11 Optical port FP control Open close Controllable 12 Optical port FR control Open close Controllable 13 Optical port SD status Normal abnormal Not controllable jg OPUCAL port RA able disable Controllable 15 Traffic statistic receiving the number of bits on electrical port Not controllable 16 Traffic statistic transmitting the number of bits on electrical port Not controllable RA SECOM Raisecom Technology Co Ltd 7 2 Configure the module In the above table the configurable items can be configured through config module command These items includes turn on or turn off electrical port RX to TX fault
12. ri indicator Ee OFF electrical port is abnormal cal Electrical port Tx TX ON electrical port is transmitting data interfa indicator OFF electrical port is not transmitting data ce Electrical port Rx RX ON electrical port is receiving data indicator OFF electrical port is not receiving data Power Power supply PWR ON power supply works properly supply indicator OFF power supply is abnormal RA SECOM Raisecom Technology Co Ltd 3 2 Front view 16 slot chassis Explanations of the indicators on 16 slot chassis are as follows PWR indicator ON chassis power supply works normal PS1 5V indicator OFF power supply PS1 for modules works normal otherwise abnormal PS1 12V indicator OFF power supply PS1 for fans works normal otherwise abnormal PS2 5V indicator OFF power supply PS2 for modules works normal otherwise abnormal PS2 12V indicator OFF power supply PS2 for fans works normal otherwise abnormal RA SECOM Raisecom Technology Co Ltd 4 Connection configuration 4 1 Interconnecting Devices Please follow the connection rules in the following table when interconnecting RC602 GE A series media converters otherwise they may not work properly Central site Remote site RC602 GE A M Master RC602 GE A M Slave RC602 GE A S1 Master RC602 GE A S1 Slave RC602 GE A S2 Master RC602 GE A S2 Slave RC602 GE A S3 Master RC602 GE A S3 Slave RC602

Download Pdf Manuals

image

Related Search

Related Contents

celle-ci continue ensuite de grossir dans la parti  ES-TX70  Mixers live 4/8 micros + 12/16 lignes + DSP 24 bits 10  14. Anhang  Paromax inc.  Manuel technique vélo à assistance électrique - Ultimate  Etude de l`arc-réflexe médullaire  いろんなものをスピーカーにする「ピタッとスピーカーplus  Manual de usuario  参考資料 現行の窓の表示制度について(PDF形式:221KB)  