1. then you will hear di di sound for confirmation Note The initial password is 1234 must be four numbers 3 1 5 Set new ID of the alarm host After passing the verification of password press SET when SET ID appears on the LCD display Input 0 six new ID numbers OK Note the initial ID is 000000 Example Set 123456 as the new ID Input 0 123456 OK then you will hear di di sound for confirmation 3 1 6 Set type of 8 wireless guarding zones After passing the verification of password press SET when SET TYPE JN M02
2. heard release the rear black key the JN M02 receiver is at learning mode then let the JN DCA JN SIB wireless infrared beam sensor send a RF signal press tamper key and hold it on then turn on the power switch to make a test RF sending the JN M02 sounds di di to show the new sensor has been learned into its memory successfully Repeat above operation to make another RF sending for learning next sensor After all devices have been learnt press the rear black key to quit learning mode and di di will be heard Beep di di for successfully learning a new device Beep didididi didididi didididi for memory is full Up to 8 JN DCA JN SIB sensors and 24 remote controllers can be learned into a JN M02 receiver 7 2 How to know which zone a sensor has been learned into Set JN M02 receiver at learning mode refer to item 7 1 for a learned sensor just press and hold the temper switch then switch on the JN DCA JN SIB beam sensor you will hear a different beep tone for each zone after di di For zone 1 one 0 3s long beep For zone 2 two short beeps For zone 3 three short beeps For zone 4 four short beeps For zone 5 one 0 3s long beep one short beep For zone 6 one 0 3s long beep two short beeps For zone 7 one 0 3s long beep three short beeps For zone 8 one 0 3s long beep four short beeps JN M02 JN M02 GSM alarm system GSM alarm system GSM alarm
3. sure that the power supply is connected correctly and turn on the host power switch The alarm host will search the GSM network automatically within 25 seconds after it is started Then the LCD display turns on and shows the time and the status of arm disarm GSM signal etc The COM is twinkling When the external power is normal the LCD display keeps on If there is no external power it is off automatically after operation III Operation steps When setting by the keyboard every time you press the button you will hear di sound for confirmation If there s no voice if no di is heart when a button is pressed hold it until di appears To cancel the input numbers please press CLS JN M02 GSM alarm system button before inputting OK If the LCD display shows FAIL please check and reset it 3 1 Set by keyboard 3 1 1 Password verification Press SET input password OK then you will hear di di sound for confirmation While SET and SMS appear on LCD display it means that the password is correct Note The initial password is 1234 must be four numbers 3 1 2 Set delete three mobile phone numbers for SMS alarm a Set the mobile phone number After passing the verification of password press SET button when SET SMS appears on the LCD display input serial number mobile phone number OK Example Set 1368888888 as the first mobile phone number for SMS a
4. system 5 4 Alarm and Handle When an alarm occurs the siren will alarm for 90 seconds to inform the Contents T Instruction neighbors At the same time the system will automatically send SMS to IT Installation 2 1 Alarm Host s section figure 2 2 Insert a valid SIM into the alarm host 23 Run circularly till one of them is answered If nobody answers the phone the report the guarding zones and dial the preset phone numbers When any phone is answered you can monitor the alarm site If the phone line is busy or can t put through the system will auto dial the next phone number system will stop dialing after auto dialing circularly for three times III Operation steps 3 1 Set by keyboard 3 1 1 Password verification VI Operation Cautions 3 1 2 Set delete three mobile phone numbers for SMS alarm By Make sure Up hirve mo waten 3 1 3 Set delete three phone numbers for auto dialing alarm Ze Anstall a hidden plate 3 1 4 Change password of the alarm host 3 Turn off the power supply before insert take out the SIM 3 1 5 Set new ID of the alarm host card 3 1 6 Set type of 8 wireless guarding zone 4 Connect the power supply firmly and provide good heat 3 1 7 Set time of the alarm host 3 1 8 Set cancel the time of arm disarm partial arm 3 1 9 Prohibit allow sending SMS while arm disarm the Siong e reno SUCH as TY Gee and computes 6 Check all the detectors periodically dissipation 5 Don t install the system clos
5. JN M02 GSM ALARM SYSTEM USER MANUAL GSM alarm system GSM alarm system 7 3 How to delete all the devices that have been learnt Press the rear black key of the JN M02 receiver and hold it on up to 10 seconds bibibibi is heard then release the rear black key all the memory is cleared Appendix Operation Guideline By following steps you can operate JN M02 easily at your first try 1 Insert a valid SIM card into the alarm host Please see 2 2 2 Make sure the power supply is connected turn on the host power switch Please see 2 3 3 Set the mobile phone telephone numbers for SMS alarm and auto dialing alarm For details please see 3 1 2 3 1 3 or 4 1 4 2 Set time of the alarm host for details please see 3 1 7 Learn all devices into JN M02 for details see item 7 1 7 2 7 3 Set zone type please see 3 1 6 for details if necessary OO Ru Change zone s name according to your needing if necessary Please see 4 6 for more details 9 Change password of the alarm host Please see 3 1 4 and 4 4 for more details if necessary 10 Set time of arm disarm according to your needing Please see 3 1 8 for more details if necessary For specific operation please read this manual carefully JN M02 GSM alarm system VIL Learning operation 7 1 How to learn a sensor remote controller into JN M02 Press the rear black key and hold it on 3 seconds later a beep tone is
6. alarm system c Timing disarm In disarming status press SET when SET Es appears on the LCD display then input time hour minute OK Example Set 16 35 as the disarm time input 1635 OK then you will hear di di sound for conformation To cancel it press 9999 OK in disarm mode 3 1 9 Prohibit allow sending SMS when arm disarm the system by controller or keyboard After passing the verification of password press SET when SET appears on LCD display input 9 OK then you will hear di di sound for confirmation 3 1 10 Alarm When the host alarms 1 SMS TEL and guarding zones will appear on the LCD display and it will drive siren to sound for 90 seconds P external power failure E SOS alarm F fire alarm 1 8 wireless guarding zone 3 1 11 Exit setting status In the setting status the host will exit automatically if there is no response within 15 seconds After setting successfully press ESC to exit IV SMS control command 4 1 Set three mobile phone numbers for SMS alarm Input SMS 4 numbers for password DD serial number mobile phone number JN M02 GSM alarm system appears on the LCD display Input zone numbers When there is illegal intrusion the zones that can alarm in partial arm mode OK Example Set zone 4 6 8 as alarm zones in partial arm mode input 4 6 8 OK then you will hear di di sound for c
7. e to the objects which generate system by controller or keyboard AG 3 1 10 Alarm 7 Inspect the GSM alarm system periodically 3 1 11 Exit setting status 8 This product is designed for the indoor use rather than outdoor IV SMS control command 4 1 Set three mobile phone numbers for SMS alarm use 4 2 Set three phone numbers for auto dialing alarm 4 3 Delete alarm phone numbers 4 4 Change password of the alarm host 4 5 Arm disarm 4 6 Change guard zone s name JN M02 JN M02 GSM alarm system a Arm Press fm on remote controller the host will make di sound the LCD display is on E is twinkling 30 seconds later the host enters into arm mode and the db is on If you want to arm the system quickly i please press 1 when da is twinkling b Partial arm press 9 the host will make di sound the LCD display is on O is twinkling 30 seconds later the host enters into partial arm y mode and O is on Press the 4 the host will enter into partial arm mode immediately c Disarm Press mi to close the system the host enters into disarm status after the host makes di di sound and the mi is on 5 2 Emergency alarm When an emergency alarm occurs press 4 and the host will enter into emergency alarm status immediately and the siren will alarm for 90 seconds to inform the neighbors At the same time it will automatically dial
8. host immediately then the host sends alarm SMS to its preset mobile phone numbers and meanwhile dials its preset telephone mobile phone numbers automatically and drive wiretap In addition the color LCD can show the time date and the status of arm disarm GSM signal power alarm etc With the LCD it is very easy for you to operate Following are the specific functions 1 With French Wavecome double frequency GSM module 2 With color LCD show screen and keyboard on the host 3 10 wireless guarding zones 1 wireless SOS zone 1 fire alarm zone and other 8 wireless guarding zones can be defined by user and 1 external power failure alarm zone 4 Send SMS to 3 preset mobile phone numbers automatically while alarming Nn Call 3 preset phone numbers automatically and monitor at site while alarming nN Set the time of arm partial arm disarm A Arm disarm by the keyboard on the host remote controller or SMS oo Program the alarm host by keyboard or SMS JN M02 GSM alarm system 4 5 Arm disarm SMS for remote arm 4 numbers for password A1 SMS for remote disarm 4 numbers for password A2 Example The host s password is 1234 If you want to set the host in arm mode Send SMS 123441 4 6 Change zone s name Input SMS 4 numbers for password DM zone s code 2 numbers changed name Reply SMS Changed zone s name Example The password is 1234 If you want to change zone 06 s
9. larm Input 1 1368888888 OK then you will hear di di sound for confirmation According to the method you can finish the setting of the other two mobile phone numbers Note Serial number can only be 1 2 3 and the number 1 1s the first mobile phone number for SMS alarm The phone No must be less than in 20 numbers b Delete the mobile phone number Input serial number OK then you can cancel the mobile phone numbers 3 1 3 Set delete three phone numbers for auto dialing alarm If you do not need this function ignore the following setting a After passing the verification of password press SET button when JN M02 GSM alarm system SET TEL appears on the LCD display Input serial number phone number OK Example Set 1368888888 as the first phone number for auto dialing alarm Input 4 1368888888 OK then you will hear di di sound for confirmation Note Serial number can only be 4 5 6 and the number 4 is the first phone number for auto dialing alarm The phone number can be mobile phone or telephone but mustn t be more than 20 numbers b Delete the phone number Input serial number OK then you can cancel it 3 1 4 Change password of the alarm host After passing the verification of password press SET when SET PAS appears on the LCD display Input 7 new password OK Example Set 4321 as the new password Input 7 4321 OK
10. name to be PIR alarm for bedroom Send SMS 1234DM06 PIR alarm for bedroom Note Changed name should be less than 24 characters Zone s code 01 to 08 each code with two numbers 4 7 Inquire host s arm disarm status Input SMS 4 numbers for password W1 Reply SMS The host s arm disarm status 4 8 Inquire host s external power status Input SMS 4 numbers for password W2 Reply SMS The host s external power status V Usage 5 1 Arm partial arm disarm by remote controller JN M02 GSM alarm system Example Set 1388888888 as the first mobile phone number for SMS alarm The host s password is 1234 Send SMS 1234DD11388888888 Note The serial number shows alarm seguence must be 1 2 3 4 2 Set three phone numbers for auto dialing alarm Input SMS 4 numbers for password DD serial number phone number Example Set 01088888888 as the first phone number for auto dialing alarm The host s password is 1234 Send SMS 1234DD401088888888 Note The serial number shows alarm sequence must be 4 5 6 4 3 Delete alarm phone numbers Input SMS 4 numbers for password DD serial number Example The host s password is 1234 If you want to delete the first alarm phone number Send SMS 1234DD1 Note The serial number shows alarm sequence must be 1 2 3 4 5 6 4 4 Change password of alarm host Input SMS 4 numbers for password DD 7 4 new numbers for password Example The initial
11. onfirmation When alarming zone 4 6 8 will alarm but other five zones will not alarm in partial arm mode 3 1 7 Set time of the alarm host After passing the verification of password press SET when SET appears on the LCD display Input 8 year month day hour minute second each with two numbers OK then you will hear di di sound for confirmation Example Suppose the present time is 12 13 05 and the date is 08 01 2007 input 8 070108121305 0K 3 1 8 Set cancel the time of arm disarm partial arm a Timing arm In arming status press SET when SET appears on the LCD display then Input time hour minute OK Example Set 16 08 as the arm time input 1608 OK then you will hear di di sound for confirmation To cancel it press 9999 OK in arm mode b Timing partial arm In partial arm status press SET when SET appears on the LCD display then input time hour minute OK Example Set 16 25 as the partial arm time input 1625 OK then you will hear di di sound for confirmation To cancel it press 9999 OK in partial arm mode JN M02 GSM alarm system antenna MIC LCD display pa i DG EXT MIC ae EXT MIC DOGS 00 es Keyboard Siren socket Power socket Power switch Cover 2 2 Insert a valid SIM into the alarm host Before installing the host please insert SIM card through the real slot 2 3 Run Make
12. password is 1234 if you want to set 5678 as the new password Send SMS 1234DD75678 JN M02 GSM alarm system 9 Modify the name of 8 wireless guarding zones and inguire the status of alarm host by SMS demand 10 Define the 8 wireless guarding zones as arm partial arm by keyboard on the alarm host 11 With standby rechargeable battery 12 The alarm host automatically stores system status while its power is off 13 Connect with the alarm center through GSM network Specification a GSM GSM frequency 900 1800MHz or 850 1900MHz optional Consumption 1W while sending message b Working frequency of detectors 315M amp 433M optional c External power failure alarm Start time less than 2s d Alarm response time Less than 8s GSM in normality e The volume of siren 110db f Power Power requirements AC 110 220V 50Hz or 60Hz Working power consumption less than 3W JN M02 GSM alarm system Standby battery DC 8 4V Standby battery working hours more than 15 Hours g Working conditions Operating temperature 20 C 60 C Humidity 20 to 95 h Weight of alarm host Net weight 0 5Kg Gross weight 0 75Kg i Dimension of alarm host Dimension 160mm Long x113mm Wide x38mm High IL Installation 2 1 Alarm Host s section figure G 2 KA q Y KA Y OS g Go WY eo He hE OG bp Cay ay Ch Rao Sa p Uo Ny Org O Ip Oy Partial arm Disarm Year Month Day Hour Minute JN M02 GSM
13. the preset alarm phone numbers cycled for three times and send SMS of Emergency alarm 5 3 External power failure alarm When the system checks out that there is something wrong with the external power or the external power is off for more than 2 seconds it will enter into alarm status immediately At the same time the system will automatically dial the preset phone numbers cycled for three times and send the SMS of Emergency alarm refer to item 4 8 to send a inquiry to the host control panel External power failed will be received When the power supply is on the system will stop alarming immediately and send the SMS of External power is OK JN M02 GSM alarm system 4 7 Inquire host s arm disarm status 4 8 Inquire host s external power status V Usage 5 1 Arm partial arm disarm by remote controller 5 2 Emergency alarm 5 3 External power failure alarm 5 4 Alarm and handle VI Operation Cautions VI Learning operation 7 1 How to learn a sensor remote controller into JN M02 7 2 How to know which zone a sensor has been learnt into 7 3 How to delete all the devices that have been learnt Appendix Operation guideline JN M02 GSM alarm system 1 Instruction The alarm system adopts SMS data transmission and voice platform of GSM network to send control command and receive alarm remotely The system can be set delayed arm When a signal is detected by detectors the detectors will send alarm signal to

Download Pdf Manuals

image

Related Search

Related Contents

Manual de usuario  American Standard Laurel Toilet Seat 5311.01 User's Manual  SERVOSTAR 601...620  Série R Manuel d`installation Série R Manuel d`installation  2011 Spanish Pro-Series Round Frame Pool Manual  レスリング表示システム WR−400  Service Manual 2/1999  L`attestation obLigatoire de prise en compte de La régLementation  Philips AVENT 220-240 V User's Manual  D-Aladin ONE I+II.indd  