Home
DVI Galvanic Isolator
Contents
1. EXT DVI Gl User Manual Release A2 DVI Galvanic Isolator Important Safety Instructions 10 11 12 13 14 15 GENERAL SAFETY INFORMATION Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this product near water Clean only with a dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions Do not install or place this product near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manufacturer To reduce the risk of electric shock and or damage to this product never handle or touch this unit or power cord if your hands are wet or damp Do not expose this product to rain or moisture Unplug this apparatus during lightning storms or when unused for long perio
2. Connect the included DVI cable from the imaging source e g camera to the DVI In port on the DVI Galvanic Isolator 2 Connect a DVI cable from the DVI Out port on the DVI Galvanic Isolator to a video scaler or high resolution display 3 Connect a bonding wire from the Grounding Terminal to an approved safety ground 4 Connect the included locking power supply to the DVI Galvanic Isolator and connect the AC power to an available electrical outlet Do not overtighten the locking power connector Sample Wiring Diagram ED DVI CABLE EE Laparoscopic Camera DVI Galvanic Isolator Monitor Display EXT DVI GI page 4 Getting Started Installation Sample Application The illustration below depicts a medical application using a galvanic isolator The DVI Galvanic Isolator provides an electrical barrier between low voltage electronics and an externally exposed imaging system Unwanted contact with sources of high voltage can cause damage to the low voltage electronics within a camera or other imaging source The DVI Galvanic Isolator protects both the imaging source and patient from misdirected electrical voltages outside of the working zone indicated by the red plane Imaging source endoscopy camera DVI cable input DVI Galvanic Isolator Isolated working zone Earth ground from grounding terminal DVI cable output High resolution imaging system page 5 02 Appendix SurtaceMount
3. changes in the hardware packaging and any accompanying documentation without prior written notice HDMI the HDMI logo and High Definition Multimedia Interface are trademarks or registered trademarks of HDMI Licensing in the United States and other countries 2012 Gefen LLC All Rights Reserved All trademarks are the property of their respective owners iv Operating Notes Operation is subject to the following conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation This product is not designed for marine use Do not use this product near water or in a wet environment Always connect a bonding wire between an approved safety ground and the grounding screw on the chassis N IMPORTANT The grounding stud must be permanently connected to protective ground by wiring not less than 16 AWG Features and Packing List Features Provides up to 5kV full galvanic isolation between DVI components Supports resolutions up to 1920 x 1200 WUXGA HDCP pass through EDID pass through HPD pass through Grounding terminal Isolation between the input and out DVI Locking power supply connector Grounding Terminal Compliant with Medical Standards EN60601 1 and EN60601 1 2 3rd Edition Packing List The DVI Galvanic Isolator ships with the items listed below If any of these items ar
4. ds of time Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Batteries that may be included with this product and or accessories should never be exposed to open flame or excessive heat Always dispose of used batteries according to the instructions DVI Galvanic Isolator Warranty Information Gefen warrants the equipment it manufactures to be free from defects in material and workmanship If equipment fails because of such defects and Gefen is notified within two 2 years from the date of shipment Gefen will at its option repair or replace the equipment provided that the equipment has not been subjected to mechanical electrical or other abuse or modifications Equipment that fails under conditions other than those covered will be repaired at the current price of parts and labor in effect at the time of repair Such repairs are warranted for ninety 90 days from the day of reshipment to the Buyer This warranty is in lieu of all other warranties expressed or implied including without limitation any implied warranty or merchantability or fitness for any particular purpose all of which are expressly disclaimed 1 Proof of sale may be required in ord
5. e not present in your box when you first open it immediately contact your dealer or Gefen 1 1 1 1 DVI Galvanic Isolator 6 ft Dual Link DVI Cable 5V DC Locking Power Supply Quick Start Guide ui vi Table of Contents 01 Getting Started Panel EayQU ec 2 lascio H E 4 Connecting the DVI Galvanic Isolator 4 Sample Wiring Diagrami sosna irene aaa rad 4 Sample Application Fee ente 5 02 Appendix Surface Mounting Instructions Specification sr ls viii 01 Getting Started Panel Layout Installation Connecting the DVI Galvanic Isolator Sample Wiring Diagram Sample Application Getting Started Panel Layout page 2 Getting Started Panel Layout Connect the included DVI cable between the imaging source e g Endoscopic camera and the DVI In port Connect the included 5V DC power supply to this locking power receptacle This LED will glow bright blue once the included 5V DC power supply has been properly connected between the locking power receptacle and an available electrical outlet Connect a DVI cable between this port and a high resolution display 5 Grounding Terminal The Grounding Terminal must be permanently connected to protective ground by wiring not less than 16 AWG page 3 7 Setting Started ____aa Installation Connecting the DVI Galvanic Isolator 1
6. er to claim warranty Customers outside the US are responsible for shipping charges to and from Gefen Copper cables are limited to a 30 day warranty and cables must be in their original condition The information in this manual has been carefully checked and is believed to be accurate However Gefen assumes no responsibility for any inaccuracies that may be contained in this manual In no event will Gefen be liable for direct indirect special incidental or consequential damages resulting from any defect or omission in this manual even if advised of the possibility of such damages The technical information contained herein regarding the features and specifications is subject to change without notice For the latest warranty coverage information refer to the Warranty and Return Policy under the Support section of the Gefen Web site at www gefen com PRODUCT REGISTRATION Please register your product online by visiting the Register Product page under the Support section of the Gefen Web site DVI Galvanic Isolator Contacting Gefen Technical Support Gefen LLC c o Customer Service 20600 Nordhoff St Chatsworth CA 91311 Telephone 818 772 9100 800 545 6900 Fax 818 772 9120 Email support gefen com Visit us on the Web www gefen com Technical Support Hours 8 00 AM to 5 00 PM Monday Friday Pacific Time DVI Galvanic Isolator is a trademark of Gefen LLC Important Notice Gefen LLC reserves the right to make
7. ingllnstr etionse s o 8 SA ee EET 9 Getting Started Surface Mounting Instructions The Gefen DVI Galvanic Isolator can be mounted on any flat surface using wood drywall Screws as shown in the diagram above There should be an inch or two of clearance between the edges of the unit and any walls or vertical surfaces to allow for enough clearance for connection and disconnection of DVI cables For installation on a drywall surface use a 6 drywall screw When installing it is recommended to use the center hole on a stud page 8 Appendix Specifications 165 MHz 1 x LED blue Maximum Pixel Clock Power Indicator Video Input 1 x DVI 29 pin female digital only Video Output 1 x DVI 29 pin female digital only Locking type Storage Temperature 4 to 158 F 20 to 70 C Operating Temperature 32 to 113 F 0 to 45 C Relative Humidity 10 to 90 non condensing Atmospheric Pressure 50 kPa to 106 kPa Power Input 5VDC Dimensions W x H x D 5 8 x 1 2 x 8 5 146mm x 30mm x 85mm Unit Weight 0 4 Ib 0 18 kg page 9 Stretch it Switch it Split it Control it Gefen s got it amp 20600 Nordhoff St Chatsworth CA 91311 1 800 545 6900 818 772 9100 fax 818 772 9120 www gefen com support gefen com O Y E CE This product uses UL or CE listed power supplies
Download Pdf Manuals
Related Search
Related Contents
Panel modular de policarbonato celular NO PROTEGIDO Le tram sur les bons rails ZoomText 10.1 User Guide Addendum Samsung 55" General display 550DX Manual Time Setting: Tripp Lite 1ft L6-20P - 2 X L6-20R Automated network configuration of connected device Livre de l`élève + CD Newstar FPMA-D910 flat panel desk mount Copyright © All rights reserved.