Desire Series D22 Installation Guide

image

Contents

1. Install the divider in the junction box with the provided screw separating the power side from the data side Strip the supply power wires back 1 2 inch 13mm Use a 2 Phillips screwdriver to remove the two screws retaining the Canopy to the mounting plate Following the label on the mounting plate attach the supply power wires to the power block on the mounting plate Refer to Canopy Fixture Mounting Plate and Termination Board on page 4 Attach the power supply ground wire to the mounting plate Plug in the input DMX RDM connector and thru DMX RDM connector if used to the appropriate location on the terminal board Attach the mounting plate to the junction box ensuring the cables are properly routed inside the box Desire Series D22 Canopy Fixture Installation Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9 Strip the fixture s power wires back 1 2 inch 13mm Using the hole in the mounting bracket hang the canopy on the Installation hook Following the label on the mounting plate attach the power wires to the power block Secure the fixture ground wire to the mounting plate If the fixture is the last fixture on a DMX RDM line terminate the fixture See Termination on page 4 Insert the DMX RDM connector into the Terminal board To determine the alignment of the canopy orientate the fixture to where it will need to be focused Align the holes in the canopy
2. 7066A1030 The Canopy fixture is terminated on the Termination board inside the canopy Canopy Fixture Mounting Plate and Termination Board Mounting plate 7_ gt D Termination 4 board Power block Termination The Canopy fixture is terminated with the S1 switch on the Termination board Set the switch to the ON position to terminate the last fixture All others on the DMX RDM line must be set to OFF D22 Data connector Termination switch 4 Desire Series D22 Installing the Canopy Fixture The Canopy D22 Desire Series is installed on to a RACO 232 series 4 x 2 1 8 inch deep double junction box The fixture is supplied with a divider to separate the data network from the line voltage inside the junction box Installation hook Data Voltage divider lt SS amp h DS AS h foe 5 07 N a N oy aL Mounting plate Junction box assembly not provided Canopy CAUTION Separate the line voltage from the data side in the junction box Install the voltage barrier provided by ETC DMX RDM Cable Installation Step 1 Terminate DMX RDM input from the control source to the junction box This connection could be Belden 9729 or Category 5 If using Belden 9729 for DMX RDM input a Reference the DMX Cable Preparation for Screw Termination Setup Guide for instructions to prepare and terminate Belden 9729 for DMX input cable to the screw terminal connector b Install the
3. to the canopy and should be terminated in a voltage separated junction box provided by others The Track mount receives power through its MultiAdaptor which connects to one of two circuits Power Requirements The universal power supply accepts 100 240 VAC 50 60Hz CAUTION Do not use a fixture for any voltage for which it is not rated Do not exceed the specified voltage and current input for any fixture Connecting the fixture to a voltage outside the acceptable range may damage the unit and will void the factory warranty cD The fixture must be grounded Application appropriate electrical junction box with cord grips are required A voltage separated junction box is required A RACO 232 series 4 x 2 1 8 inch deep junction box is recommended The junction box must not interfere with fixture focusing The fixture is factory pre wired Opening the housing is not required The fixture must be connected to a non dimmable power source Dimming the unit will damage the fixture and void the factory warranty Power Connections Mains Europe North America Line Brown Black Neutral Blue White Ground Green Yellow Green Installation Termination The D22 Desire Series requires termination at the last fixture on a DMX RDM line with a 120 ohm resistor The Portable fixture is self terminated The Track fixture is terminated with a DataTrack DMX Term Block ETC Part
4. 20 8896 2000 Rome IT m Via Pieve Torina 48 00156 Rome Italy m Tel 39 06 32 111 683 m Fax 44 0 20 8752 8486 Holzkirchen DE m Ohmstrasse 3 83607 Holzkirchen Germany m Tel 49 80 24 47 00 0 m Fax 49 80 24 47 00 3 00 Hong Kong m Rm 1801 18 F Tower 1 Phase 1 Enterprise Square 9 Sheung Yuet Road Kowloon Bay Kowloon Hong Kong m Tel 852 2799 1220 Service Americas service etcconnect com m UK service etceurope com m DE techserv hoki etcconnect com m Asia service etcasia com Web www etcconnect com m Copyright 2013 ETC All Rights Reserved m Product information and specifications subject to change 7411M2100 m Rev C m Released 2013 11 m ETC intends this document to be provided in its entirety Desire D22 Page 1 of 8 Electronic Theatre Controls Inc Control Portable The Portable D22 is provided with 5 pin XLR connectors on the back for in and thru connection to a DMX RDM control network Canopy Mount The D22 Canopy Mount fixture is provided with one cable which provides power and data into the canopy A termination board is incorporated into the mounting plate for installation onto a voltage separated junction box junction box provided by others voltage barrier provided by ETC and provides termination for control wiring e Connection of the D22 data cable to a provided screw down connector which is pre wired at the factory The connector is plugged into the termination board The braided shield is connect
5. ETC Installation Guide Desire Series D22 Introduction ETC s Desire D22 is designed for indoor installations and has a rugged die cast enclosure steel mounting yoke and noise free fan less operation The D22 can be pipe mounted with a C clamp canopy mounted or track mounted Mounting accessories are available Contact ETC Customer Service for assistance contact information is located at the bottom of this page Portable For information about the operation of the D22 Desire Series refer to Desire Series by ETC D22 D40 D40XT D60 User Manual ETC manuals are available for download at http Awww etcconnect com downloads aspx CAUTION Do not attempt to install or use a fixture until you read and understand the installation instructions and safety labels WARNING This fixture must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations Specifications Environment Operates in ambient temperatures of 0 C to 40 C 32 F to 104 F CAUTION Risk of eye injury Do not stare directly into the light Do not operate in proximity to flammable materials Corporate Headquarters m 3031 Pleasant View Road P O Box 620979 Middleton Wisconsin 53562 0979 USA m Tel 608 831 4116 m Fax 608 836 1736 London UK m Unit 26 28 Victoria Industrial Estate Victoria Road London W3 6UU UK m Tel 44 0 20 8896 1000 m Fax 44 0
6. circuit is a constant power circuit Dialing into a dimmable circuit may cause fixture damage that will void the ETC warranty Step 4 Focus the fixture Addressing Fixture addresses must be set between 1 and 510 Each Desire fixture must be considered a separate DMX device for the purpose of DMX line loading calculations i Note No more than 32 DMX devices can be daisy chained together on a single run For runs of fixtures totaling more than 32 DMX devices a DMX splitter will need to be used to split the DMX runs When using RDM with track fixtures ETC recommends connecting no more than 20 fixtures on a single run Initial Power Up Control and configuration of the Desire D22 can be achieved over a DMX RDM control network or directly from a connected computer running appropriate software When controlling the D22 directly from a PC a Gadget Interface or DMX RDM gateway is required 8 Desire Series D22
7. ed inside the fixture and should not be connected in the canopy Connection of DMX RDM input from the control source This connection can be cable type Belden 9729 or equivalent to the provided screw terminal When using Cat5 or equivalent cable type for DMX RDM input order a Cat5 termination kit from ETC part number 4100A1013 Cat5 termination instructions and an IDC connector are provided with the termination kit Connection of DMX RDM thru to the next DMX device This connection may also be either Belden 9729 or Cat5 The connector is not provided Order the appropriate DMX termination kit for the cable type used from ETC Belden 9729 use 4100A1012 or Cat5 use 4100A1013 Termination instructions and the appropriate connector is provided with the termination kit Up to 32 DMX RDM devices can be daisy chained together per data run Track Mount The Track Mount fixture s power and data connections are made through the Eutrac MultiAdaptor mounting adapter No further wiring to the fixture is required Refer to the track installation instructions for more information Desire Series D22 A Electrical WARNING Ensure the main power supply is off before installing or wiring a fixture The Desire D22 Portable is provided with a permanently installed power cord with 3 prong Edison connector Region specific connectors are available Contact ETC for available options The Canopy fixture is provided with power and data wired
8. screw terminal connector with wires terminated to the DMX RDM Input receptacle on the termination board From a DMX RDM source 4 to 8 n c Belden 9729 or equivalent wire termination to screw connector If using Category 5 for DMX RDM input a Step 2 Step 3 Reference the Cat5 Cable Preparation for IDC Termination Setup Guide for instructions to prepare and terminate Category 5 for DMX RDM input cable to the insulation displacement connector Install the IDC connector with wires terminated to the DMX RDM Input receptacle on the termination board Optionally terminate DMX RDM thru to the next device in the DMX data run Up to 32 DMX RDM devices can be daisy chained together per data run Refer to Control on page 2 Reference the specific termination setup guide for the type of cable used either Belden 9729 or Category 5 in the installation Termination kits are ordered separately Install the connector with wires terminated Cats or equivalent wire to the DMX RDM Thru receptacle on the termination to IDC connector termination board Terminate DMX RDM data signal for the last DMX RDM device in the data run by setting the termination switch on the termination board to ON All other devices in the data run maintain the factory default termination switch setting OFF Refer to Termination on page 4 Canopy Mounting Plate Installation Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7
9. with the a Installation pest i hook and La bracket mounting posts on the mounting plate and using a 2 Phillips screwdriver secure the canopy to the mounting plate with the canopy screws Focus the fixture Installing the Portable Fixture The C clamp attaches the fixture to the mounting pipe The position of the fixture can be adjusted once it is mounted Tightly fasten the C clamp to the yoke with the provided yoke bolt and lock washer Step 1 Place the C clamp on the mounting pipe and then tighten the pipe bolt to secure it Safety Step 2 Loop a safety cable over the pipe and attach se 100p the ends to the safety cable loop on the body aN of the fixture CN Step 3 Loosen the C clamp yoke bolt and rotate the yoke to the desired position Step 4 Tighten the bolt to lock the fixture CAUTION Tighten the C clamp pipe bolt to about 18 inch Ibs Approximately finger tight plus up to one quarter turn Do not use excessive force Installing the Track Fixture Step 1 Insert the DataTrack adapter into the track The adapter only fits into the track one way with the tabs nesting into the track s groove Step 2 Rotate the locking mechanisms to lock the adapter into place Step 3 Use the circuit selection lock to select circuit 1 or 2 The desired circuit number should point toward the center of the adaptor Gy WARNING When using the circuit selection lock ensure the selected

Download Pdf Manuals

image

Related Search

Related Contents

Fiber-Optic MXI-Express x4 for PXI Express Series User Manual  Manual de Instalação  表紙 - FUNAZAWA  LAVINA® 32 -S User Manual - Polished Concrete Solutions  GRABADORA DE MINIDISCOS Manual de Instrucciones    Dynamic Simulation of Jumping  User manual of super-intelligent wind and solar hybrid  Definer™ 220 Series User Manual  Panel de mando AOP30 - Industry Support Siemens  