1042 SERIES - Holmes Heating
Contents
1. Mount the self tapping saddle valve on either a cold or a hot water pipe A side or top mount is best to avoid clogging from pipe sediment Connect 1 4 O D tubing to the saddle valve Copper tubing requires a brass compression nut and brass sleeve Plastic tubing requires a brass insert inside the tubing a plastic sleeve on the outside with a brass compression nut NOTE DO NOT USE PLASTIC TUBING ON HOT WATER OR IN CONTACT WITH ANY HOT PLENUM SURFACE OR DUCT INSTALLATION OF THIS SADDLE VALVE MUST MEET OR EXCEED LOCAL CODES AND ORDINANCES SADDLE VALVE INSTALLATION INSTRUCTIONS Copper Pipe 1 Retract piercing pin into valve body by turning handle counterclockwise Screw valve body into upper bracket and tighten Place rubber gasket over piercing pin Assemble saddle valve over copper pipe using enclosed screws nuts and lower bracket Tighten screws evenly and firmly Brackets should be parallel Complete compression connection to saddle valve outlet Turn handle clockwise to pierce tubing and close saddle valve Turn handle counterclockwise to open saddle valve leave open for several seconds to flush dirt from pipe and tubing Steel Brass or Hard Plastic Pipe 1 Shut off water supply and drain pipe 2 Turn handle clockwise to expose piercing pin and close saddle valve Place rubber gasket over piercing pin Drill 1 8 hole in pipe using a hand crank drill to avoid shock hazard
2. S Q a a m gt smallest household light bulb The heat necessary for evaporating gt gt nm lt a am RS 2 Sm m Water is produced by the furnace 58 D a Io O49 The water supply to the humidifier is controlled by the electric solenoid oda a a 2 a 22m valve The humidistat connected in series with the solenoid provides 9 9 me 290 5 1 low voltage control of the humidifier The humidistat is designed for 0 m a wall mounting in the living area or surface mounting on the return air 8 duct ELECTRICAL RATING 24 VAC 60 Hz DO NOT SET D J g Zz 10 RELATIVE HUMIDITY TOO HIGH DURING COLD WEATHER 0 0 z S Se D EXCESSIVE HUMIDITY MAY CAUSE CONDENSATION ON ox O Os 1 8 4 rm WINDOWS OR IN WALLS REFER TO RECOMMENDED SETTINGS S S 2 52 5 gt DESCRIBED IN THE HUMIDISTAT OWNERS MANUAL 9 6 m A zZ g 24 a Water flows through a strainer is metered through an orifice to provide Zn o Ro LR By a s g a the proper amount of water and is supplied to the evaporator pad by cm n T gt lt D m thedistributor trough Approximately 200 CFM of air is by passed from z m oa a 5 2 the warm air plenum through the humidifier and returned to the cold air aT gt plenum Moisture is evaporated to the air passing through the o Z evaporator pad m 5 Minerals are not blown into the air stream as occurs in atomizing o m O hu
3. 23 20 solenoid valve Remove the brass strainer body P N 990 18 from the solenoid valve Carefully pull the strainer screen P N 990 17 from the orifice fitting P N 990 16 Clean the mineral deposits from all parts If the orifice is OF 18YC 25 clogged it may be opened by inserting a small needle Reinsert the filter into the orifice fitting and screw the brass 10 F 29 30 strainer body into the solenoid valve 5 Reconnect the 1 4 water line to the solenoid valve if necessary Turn on the water supply and check all points for 20 F 7C 35 leakage The operation of the unit may be checked by starting the furnace The humidifier operates only when the 30 DC 40 furnace blower is running or the burner circuit is energized The humidifier is now ready for operation 6 During the summer turn off water supply and electrical power to humidifier Close air damper 2100r gramm HOW THE HUMIDIFIER WORKS 2 0 lt gt lt 2 2 22Z7 2235734397490 5734327393 02 zn20 mm lt D m h E D m a Py OT The operating principle of the humidifier is based on the most efficient ag ga oD 2 e a 2 Gj amp m and economical means of evaporating water to the air The humidifier gt S E 3 Z E U gt 32 A gt On si uses only six watts of electrical power during operation less than the a a oO 2 S
4. 5 Assemble saddle valve over steel brass or hard plastic pipe using enclosed screws nuts and lower bracket Tighten screws evenly and firmly Brackets should be parallel Complete compression connection to saddle valve outlet O O1 NO Attach solenoid valve to side of humidifier cabinet with flow arrow pointing up using thumb nuts provided Do not reverse brass fittings as valve will not function if flow is reversed Assemble distributor tube so that it is directed into the center opening of the distributor trough cover Connect 1 4 water supply tube to brass filter at inlet of solenoid DO NOT USE PLASTIC TUBING IN CONTACT WITH ANY HOT PLENUM SURFACE OR 8 Turn handle counterclockwise to open saddle valve leave open for DUCT IF USING PLASTIC TUBING USE TUBE several seconds to flush dirt from pipe and tubing SUPPORT PROVIDED Threaded Pipe Fittings 1 Turn handle clockwise to expose piercing pin and close saddle valve Seal valve body threads using pipe tape or sealant Install valve into 1 8 NPT fitting Complete compression connection to saddle valve outlet Turn handle counterclockwise to open saddle valve leave open for several seconds to flush dirt from pipe and tubing gt WIRING D Please refer to the installation instructions included with the Humidistat Turn on water supply and check operation of humidifier
5. Set humidistat to a demand setting With the furnace off the solenoid valve should be closed Start the furnace the solenoid valve should open when the blower or burner circuit is energized Check flow of water through distributor trough and evaporator pad The standard 990 16 76 orifice will supply approximately 3 5 GPH of water at a line water pressure of 60 psi For low water pressures 20 40 psi a larger orifice 990 16 75 is available to provide the same flow Leave humidistat set at the recommended setting Connect drain hose to 5 8 spout on humidifier cabinet using hose clamp provided Run 5 8 hose to suitable drain such as floor drain sewer or laundry sink Be sure hose has continuous slope and is not kinked at any point CAN M ENS Wy gay one an TremenrProoucrs HUMIDIFICATEUR DERIVATION VENTILEE INSTALLATEUR VEUILLEZ REMPLIR ET POSTER LA CARTE DE GARANTIE UNE FOIS L INSTALLATION TERMIN E LAISSER LES DIRECTIVES D INSTALLATION AU PROPRI TAIRE DE LA MAISON 1 042 SERIES PR CAUTION L installateur doit tre un technicien qualifi et exp riment Couper l alimentation lectrique avant de commencer l installation Ne pas installer l appareil dans un endroit o la temp rature peut descendre POUR UNE INSTALLATION SUR LA sous 0 C 32 F ou si la temp rature du plenum d passe 93 C 200 F Lors d un branchement un circuit de SURFACE VERTICALE DU PLENUM DE ventilateur a plusieurs vitesses voir l
6. du corps de la vanne avec un scellant ou du ruban adh sif 8 Installer la vanne dans un raccord NPT de 3 mm 1 8 po 4 Terminer la connexion de compression vers la sortie du robinet vanne trier 5 Tourner la poign e dans le sens antihoraire pour ouvrir le robinet vanne trier et le laisser ouvert pendant quelques secondes pour vacuer la salet du tuyau et de la tuyauterie C BLAGE Veuillez consulter la notice d installation fournie avec l humidistat Raccorder le boyau de vidange au bec de 5 8 po sur l humidificateur l aide du collier de durite fourni Acheminer un boyau d un diam int de 1 6 cm 5 8 po vers un drain ad quat comme un drain de sol d gout ou d vier de lavage S assurer que le boyau est en pente continue et n est d form en aucun point Attacher la vanne lectromagn tique sur le c t du bo tier de l humidificateur avec la fl che de d bit orient e vers le haut l aide des vis ail es fournies Ne pas inverser les raccords en laiton car le robinet ne fonctionnera pas ad quatement si l cou lement se fait en sens inverse Monter le tuyau du distributeur de fa on qu il se dirige vers l ouverture centrale du couvercle du bac de distributeur Raccorder le tuyau d alimentation d eau de 1 4 po au filtre en laiton de l entr e du sol no de AUCUN TUYAU EN PLASTIQUE NE DOIT ENTRER EN CONTACT AVEC DES CONDUITS O DES SURFACES DE PL NUM CHAUDS POUR
7. humidifier For plenum sizes 9 1 2 to 15 use 1040AD adapter plate and five screws 3 screws in top supplied with DM model only Stick mounting template in place making sure the template is level Do not install humidifier or 6 bypass pipe where the blanked off ends of a cooling coil will restrict air flow to the humidifier Extend horizontal centerline from template to the adjacent plenum Scribe 6 circle 10 to 15 from side of humidifier on cabinet centerline using connecting collar as guide Cut out center section of template and 6 hole Hang humidifier cabinet and insert remaining four screws Tighten all 8 screws Install connecting collar after drilling 1 8 holes for screws Connect by pass pipe to collar and humidifier cabinet Using holes at top and bottom of humidifier bypass opening drill 2 1 8 holes through bypass pipe and screw by pass pipe to humidifier cabinet Center punch the four side mounting holes on the template and drill with an 1 8 drill bit Insert four sheet metal screws in the side mounting holes until the heads project about 3 8 Hang humidifier from the four screws and install drain pan evaporator pad and distributor trough Adjust humidifier until level and tighten four screws Remark four remaining holes if necessary Remove humidifier and drill four remaining holes COPPER TUBING PLASTIC TUBING
8. la vanne lectromagn tique est d faillante d connecter la ligne d alimentation en eau de 6 mm 1 4 po de la vanne lectromagn tique Retirer le corps de tamis en laiton P N 18 25 990 18 de l lectrovanne Retirer soigneusement le filtre tamis P N 990 17 du raccord de l orifice P N 990 E o a fae a se 10 29 C 30 16 Nettoyer les d p ts de min raux de toutes les pi ces Si l orifice est bloqu on peut l ouvrir en y ins rant une petite aiguille R ins rer le filtre dans le raccord de l orifice et visser le corps de tamis en laiton dans l lectrovanne 20 7C 35 5 Raccorder la conduite d eau de 6 mm 1 4 po la vanne lectromagn tique au besoin Ouvrir l alimentation en 30Y DC 40 eau et v rifier tous les points de fuite Le fonctionnement de l appareil peut tre v rifi en d marrant la fournaise L humidificateur fonctionne uniquement lorsque le ventilateur de la fournaise est en marche ou que le circuit du br leur est activ L humidificateur est maintenant pr t fonctionner 6 Pendant la p riode d t fermer l alimentation en eau et en lectricit de l humidificateur Fermer l amortisseur air FONCTIONNEMENT DE L HUMIDIFICATEUR Le principe de fonctionnement de l humidificateur est bas sur la fa on la plus efficace et la plus conomique d vaporer l eau dans l air L humidificateur utilise uniquement six 6 watts de courant lectrique lorsqu i
9. 63 45 8 359 882 AA ose an Tree Prooucrs INSTALLER PLEASE FILL OUT AND MAIL GUARANTEE CARD AFTER INSTALLATION IS COMPLETE LEAVE INSTALLATION INSTRUCTIONS WITH HOME OWNER PRECAUTION The installer should be an experienced service technician Disconnect electrical power before beginning installation Do not install where temperatures fall below 32 degrees F or where plenum temperatures exceed 200 degrees F When wiring into a multi speed blower circuit see Step 7D INSTALLATION The humidifier may be mounted with the 6 outlet to the right or left by inverting the cabinet and reversing the positions of the distributor trough and drain SENS pan The humidifier may be mounted on the warm or WARM AIR return air plenum with equal efficiency See Typical Installations ADDITIONAL MATERIALS THAT MAY BE NECESSARY 1 1 4 diameter plastic supply tubing or 1 4 copper F ill 1042 SERIES FLOW THROUGH BYPASS HUMIDIFIER FOR INSTALLATION ON A VERTICAL PLENUM SURFACE OF ANY FORCED AIR FURNACE RETURN AIR supply tubing for hot water applications 2 6 diameter galvanized by pass pipe NT 3 electrical wire and wire nuts 4 air pressure switch G F Model 12500 suggested DRAIN WARM AIR WARM AIR HIGH BOY COUNTER FLOW LOW BOY GENERALA ire AC SERIES HIGH EFFICIENCY AIR CLEANER 7 S_ Select location on vertical surface of warm or return air plenum for mounting
10. AGE AIR FILTER GAGE OO OLL FUEL OIL FILTERS AND ACCESSORIES FORM NO 1042 29 FILE 10120 REV B Litho in U S A LIMITED WARRANTY This humidifier if properly registered by the return of the warranty registration card to the manufacturer is warranted to the consumer against defects in materials and workmanship for a period of one year from the date of installation Evaporator pads sleeves or plates are not covered by this limited warranty or any other warranties Any other defective parts will be repaired without charge except for removal reinstallation and transportation costs To obtain repair service under this limited warranty the consumer must send the defective part or the complete humidifier to the manufacturer THERE ARE NO EXPRESS WARRANTIES COVERING THIS HUMIDIFIER OTHER THAN AS SET FORTH ABOVE THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO ONE YEAR THE MANUFACTURER ASSUMES NO LIABILITY IN CONNECTION WITH THE INSTALLATION OR USE OF THIS PRODUCT EXCEPT AS STATED IN THIS LIMITED WARRANTY THE MANUFACTURER WILL IN NO EVENT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES This limited warranty gives you specific legal rights and you may also have other rights which vary from state to state Some states do not allow either limitations on implied warranties or exclusions from incidental or consequential damages so the above exclusion and limitation may not apply to y
11. LES TUYAUX EN PLASTIQUE UTILISER LE SUPPORT DE TUYAU FOURNI Ouvrir l alimentation en eau et v rifier le fonctionnement de l humidificateur R gler l humidistat en mode de demande Lorsque la fournaise est teinte la vanne lectromagn tique doit tre ferm e D marrer la fournaise la vanne lectromagn tique devrait s ouvrir lorsque le circuit du ventilateur ou du br leur est activ V rifier le d bit d eau passant par la goulotte du distributeur et le bloc vaporateur L orifice standard 990 16 76 fournira environ 3 5 gal h d eau une pression de ligne d eau de 60 psi Pour des pressions d eau basses 20 40 psi un plus grand orifice 990 16 75 est disponible pour fournir le m me d bit Laisser l humidistat au r glage recommand PARTS LIST FOR HUMIDIFIER 1137 35 TROUGH COVER 1137 4 DISTRIBUTOR TROUGH 1042 5 DISTRIBUTOR TUBE 990 13 EVAPORATOR PAD CABINET ASSEMBLY 1042 16 24 V P 103 COMPRESSION NUT P 104 COMPRESSION SLEEVE P 111 CONNECTOR SOLENOID VALVE ASSEMBLY 990 53 24 V 990 37 76 ORIFICE amp STRAINER ASSEMBLY _r 7 990 16 76 ORIFICE FITTING _ __ __ 990 17 STRAINER SCREEN 990 18 STRAINER BODY O 1137 3 DRAIN PAN E P 163 HOSE CLAMP 1099 16 DRAIN TUBE GENERAIAire RESIDENTIAL AIR TREATMENT PRODUCTS FILL OUT AND MAIL THIS WARRANTY CARD AND LITERATURE REQUEST FORM AIR CLEANERS AND AIR PURIFIERS HUMIDIFIERS DIGITAL HUMIDITY G
12. exion de compression vers la sortie du robinet vanne trier 7 Tourner la poign e dans le sens horaire pour percer le tuyau et fermer le robinet vanne trier 8 Tourner la poign e dans le sens antihoraire pour ouvrir le robinet vanne trier et le laisser ouvert pendant quelques secondes pour vacuer la salet du tuyau et de la tuyauterie Tuyau en acier en laiton ou en plastique dur 1 Fermer l alimentation en eau et vidanger le tuyau 2 Tourner la poign e dans le sens horaire pour exposer la tige de perforation et fermer le robinet vanne trier 8 Placer le joint d tanch it en caoutchouc par dessus la tige de perforation 4 Percer un trou de 3 mm 1 8 po avec une perceuse manivelle pour viter les risques de choc lectrique 5 Assembler le robinet vanne trier par dessus le tuyau en acier laiton ou plastique dur en utilisant les vis crous et supports inf rieurs fournis 6 Serrer les vis de fa on gale et ferme Les supports doivent tre parall les 7 Terminer la connexion de compression vers la sortie du robinet vanne trier 8 Tourner la poign e dans le sens antihoraire pour ouvrir le robinet vanne trier et le laisser ouvert pendant quelques secondes pour vacuer la salet du tuyau et de la tuyauterie Raccords de tuyau filet s 1 Tourner la poign e dans le sens horaire pour exposer la tige de perforation et fermer le robinet vanne trier 2 Sceller le filetage
13. f le r glage du niveau voulu d humidification par le bouton de commande sur l humidistat Laisser le bouton de l humidificateur la position HI ou WINTER Pour teindre l humidificateur fermer la vanne d alimentation en eau mettre hors tension et fermer l humidistat Si la chaudi re sert au refroidissement ou la ventilation en t r gler l amortisseur d air sur LOW ou SUMMER
14. l fonctionne c est dire moins que la plus petite ampoule lectrique de votre maison La chaleur n cessaire pour l vaporation de l eau est produite par la fournaise L alimentation en eau vers l humidificateur est contr l e par la vanne lectromagn tique L humidistat connect en s rie avec la vanne lectromagn tique fournit un contr le de basse tension l humidificateur L humidistat est con u pour le montage mural dans la partie habit e le montage fleur ou en surface sur le conduit de retour CARACT RISTIQUES LECTRIQUES 24 V c a 60 Hz NE PAS R GLER L HUMIDIT RELATIVE TROP HAUT PENDANT LA P RIODE HIVERNALE TROP D HUMIDIT PEUT ENTRAINER DE LA CONDENSATION SUR LES VITRES OU SUR LES MURS SE REFERER AUX R GLAGES RECOMMAND S SUR L HUMIDISTAT L eau s coule par une cr pine est mesur e par un orifice pour fournir la quantit ad quate et alimente le bloc vaporateur par la goulotte du distributeur Environ 5 66 m tres cubes par minute st d riv du pl num d air chaud passe par l humidificateur et est renvoy au pl num d air froid L humidit est vapor e dans l air en passant par le bloc vaporateur Les min raux ne sont pas souffl s dans le courant d air comme c est le cas avec les humidificateurs pulv risation ils restent sur le bloc vaporateur o un fort pourcentage est vacu avec les eaux us es Lorsque l humidificateur est install et fonctionne aucun r glage n est n cessaire sau
15. les s diments du tuyau Connecter un tuyau d un diam ext de 6 mm 1 4 les 4 vis Connecter le tuyau de d rivation au collier et au bo tier de po au robinet vanne trier Les tuyaux en CUNTE exigent un crou compression l humidificateur En utilisant les trous du haut et du bas de l ouverture de et un manchon en laiton Les tuyaux en plastique exigent un insert en laiton d rivation de l humidificateur percer 2 trous de 3 mm 1 8 po travers le l int rieur des tuyaux et un manchon en plastique l ext rieur avec un crou tuyau de d rivation et le visser au bo tier de l humidificateur compression REMARQUE NE PAS UTILISER DE TUYAUX EN PLASTIQUE AVEC DE L EAU CHAUDE OU SUR UNE SURFACE DE CONTACT CHAUDE DE PL NUM OU DE CONDUIT L INSTALLATION DE CE ROBINET VANNE TRIER DOIT RESPECTER OU D PASSER LES EXIGENCES DES CODES LOCAUX ET AUTRES ORDONNANCES INSTRUCTIONS D INSTALLATION POUR LE ROBINET VANNE TRIER Tuyau en cuivre 1 R tracter la tige perforation dans le corps de la vanne en tournant la poign e dans le sens horaire 2 Visser le corps de la vanne dans le support sup rieur et serrer 8 Placer le joint d tanch it en caoutchouc par dessus la tige de perforation 4 Assembler le robinet vanne trier par dessus le tuyau en cuivre en utilisant les vis crous et supports inf rieurs fournis 5 Serrer les vis de fa on gale et ferme Les supports doivent tre parall les 6 Terminer la conn
16. midifiers they are left on the evaporator pad where a high O v ov percentage is carried off with the waste water 2 8 2 a When the humidifier is installed and operating no adjustments are oF oF necessary other than setting the control knob on the humidistat to the g g un mO desired level of humidification Leave knob on the humidifier in HI or a Q a Q mE WINTER position z z To turn the humidifier off close water supply valve switch electrical D T power off and turn humidistat off If furnace is used for summer cooling z or ventilating set air damper on LOW or SUMMER LISTE DES PI CES POUR L HUMIDIFICATEUR N 1137 35 COUVERCLE DU BAC N 1137 4 GOULOTTE DU DISTRIBUTEUR N 1042 5 TUYAU DU DISTRIBUTEUR N 990 13 BLOC VAPORATEUR ASSEMBLAGE DU BO TIER N 1042 16 24 V N P 103 CROU COMPRESSION N P 104 MANCHON COMPRESSION N P 111 RACCORD VANNE LECTROMAGN TIQUE N 990 53 24 V N 990 37 76 ASSEMBLAGE ORIFICE ET TAMIS Le T N 990 16 76 GRANITURE DE LORIFICE amp N 990 17 FILTRE EAU I N 990 18 CORPS DU TAMIS i i N 1137 3 BAC DE R CUP RATION D N P 163 COLLIER DE SERRAGE XA 4 oJ N 1099 16 TUYAU D EVACUATION FORMULAIRE N 1042 29 DOSSIER 10120 REV B Lithographie aux U GARANTIE LIMIT E Cet humidificateur s il est enregistr correctement en re
17. nv Mettre la matrice de montage en place en s assurant qu elle soit niveau Ne Suspendre l humidificateur des quatre vis lat rales et installer le plateau pas installer l humidificateur ou le tuyau de d rivation de 15 cm 6 po l endroit de r cup ration l vaporateur et le distributeur Ajuster l humidificateur o l extr mit de la plaque d obturation d un serpentin refroidisseur pourra jusqu ce qu il soit d querre et serrer les quatre vis Marquer de restreindre le d bit d air vers I humidificateur Prolonger la ligne horizontale nouveau les quatre trous restants si n cessaire Enlever l humificateur et depuis le milieu du gabarit jusqu la chambre air voisine Marquer un cercle percer les quatre trous qui restent de 6 po une distance de 10 15 po du c t de l humidificateur sur la ligne centrale du bo tier l aide d un collier de raccordement pour guider TUYAUX EN CUIVRE TUYAUX EN PLASTIQUE Mia D couper la section centrale de la matrice et le trou de 6 po Poser le bo tier Monter le robinet vanne trier autotaraudeur Surum tuyau d eau chaude ou d eau de l humidificateur et ins rer les quatre vis qui restent Resserrer les 8 vis froide Un montage lat ral ou sur le dessus est id al pour viter un engorgement Installer le collier de raccordement apr s avoir perc des trous de 1 8 po pour cause par
18. ou Any questions pertaining to this limited warranty should be addressed to the manufacturer U S A The manufacturer has elected not to make available the informal dispute settlement mechanism which is specified in the Magnuson Moss Warranty Act GENERAL FILTERS INC 43800 GRAND RIVER AVE NOVI MICHIGAN 48375 1115 WWW GENERALAIRE COM CANADIAN GENERAL FILTERS LTD 39 CROCKFORD BLVD SCARBOROUGH ONTARIO M1R3B7 WWW CGFPRODUCTS COM CARE AND MAINTENANCE Your Humidifier is engineered to give helpful and trouble free humidification For maximum efficiency the following cleaning procedures should be carried out at the end of each heating season 1 Turn off water supply and electrical power to humidifier 2 Remove water distributor tube distributor trough evaporator pad and drain pan The evaporator pad may be AT removed from either the top or bottom of the humidifier Clean excessive mineral deposits from the distributor trough OUTSIDE RECOMMENDED cover drain pan and humidifier cabinet A solution of 1 2 vinegar amp 1 2 water will help loosen mineral deposits TEMPERATURE SETTING 3 If the evaporator pad has excessive mineral deposits replace with a new 990 13 evaporator pad Install trough and drain pan Replace cover and the distributor tube to proper position over the distributor trough 20 F 29 C 15 4 In heavy mineral areas or if the solenoid valve fails to function disconnect the 1 4 water supply line from the 10
19. tape 7D N IMPORTE QUELLE FOURNAISE A AIR INSTALLATION L humidificateur devrait tre mont avec le d bouch CHAUD PRORULSE de 7 po gauche ou droite en inversant le bo tier et les positions de REPRISE AIR REPRISE AIR REPRISE AIR la goulotte du distributeur et du bac de vidange L humidificateur fournit le m me rendement qu il soit install sur un pl num d air chaud ou sur un pl num de reprise d air Voir les Installations Typiques MAT RIAUX ADDITIONNELS POUVANT TRE REQUIS 1 Tube d alimentation en plastique de 1 4 po de diam tre ou tube d alimentation en cuivre de 1 4 po pour les applications pour eau chaude 2 Tuyau de d rivation galvanis de 15 cm 6 po 3 fil lectrique et serre fils 4 Commutateur de pression d air G F mod le n 12500 sugg r ENT AIR CHAUD AIR CHAUD AIR CHAUD AIR CHAUD FLUX VERS LE HAUT FLUX VERS LE BAS SOUS SOL GENERALAire sERIEs AC HAUT RENDEMENT FILTRE AIR S lectionner un emplacement sur la surface verticale d un pl num d air chaud ou Poin onner au milieu les quatre trous de montage de la matrice et percer de retour d air pour monter l humidificateur Pour les pl nums de 9 1 2 po to 15 l aide d une m che de 1 8 po Ins rer quatre vis autotaraudeuses dans po utiliser la plaque adaptatrice 1040AD et les 5 vis 3 vis en haut mod le DM les trous de montage lat ral jusqu ce que les vis d passent d e
20. tournant la carte d enregistrement de la garantie au fabriquant est garanti au consommateur contre tout d faut de mat riaux et de main d uvre pour une p riode de un 1 an partir de la date d installation Les blocs vaporateur ou les plaques ne sont pas couverts par cette garantie limit e ou par toute autre garantie Toute autre pi ce d fectueuse sera r par e sans frais hormis les co ts de d sinstallation de r installation et de transport Pour obtenir un service de r paration avec cette garantie limit e le consommateur doit envoyer la pi ce d fectueuse ou l humidificateur au complet au fabricant AUCUNE AUTRE GARANTIE QUE LA PR SENTE NE COUVRE CET HUMIDIFICATEUR LES GARANTIES IMPLICITES DE QUALIT MARCHANDE OU D ADAPTATION UN USAGE PARTICULIER SONT LIMIT ES UN 1 AN LE FABRICANT NE PEUT TRE TENU RESPONSABLE POUR L INSTALLATION OU L UTILISATION DE CE PRODUIT SAUF DE LA MANI RE INDIQU E DANS LA PR SENTE GARANTIE LIMIT E LE FABRICANT NE PEUT EN AUCUN CAS TRE TENU RESPONSABLE POUR DES DOMMAGES ACCESSOIRES O INDIRECTS Cette garantie limit e vous donne des droits l gaux sp cifiques et vous pouvez jouir d autres droits qui varient d une juridiction l autre Certaines juridictions ne permettent pas de limites sur les garanties implicites ou d exclusions pour les dommages accessoires ou indirects les exclusions sus mentionn es peuvent donc ne pas s appliquer dans votre cas Toute question relative ce
21. tte garantie limit e doit tre soumise au fabriquant U Le fabricant choisi de ne pas divulguer les termes de l accord sp cifi s dans le Magnuson Moss Waranty Act CANADIAN GENERAL FILTERS LTD 39 CROCKFORD BLVD SCARBOROUGH ONTARIO M1R3B7 WWW CGFPRODUCTS COM GENERAL FILTERS INC 43800 GRAND RIVER AVE NOVI MICHIGAN 48375 1115 WWW GENERALAIRE COM SOINS ET ENTRETIEN Votre humidificateur est con u pour fournir une humidification d appoint sans probl mes Pour b n ficier d un fonctionnement maximum suivre les tapes de nettoyage ci dessous la fin de chaque saison froide 1 Fermer l alimentation en eau et en lectricit de l humidificateur 2 Retirer le tuyau de distribution d eau le bac du distributeur le tampon d vaporateur et le bac de r cup ration LA Le tampon d vaporateur peut tre enlev du haut ou du bas de l humidificateur Nettoyer les d p ts excessifs de TEMP RATURE R GLAGE min raux dans le bac du distributeur le couvercle le bac de r cup ration et le bo tier du distributeur Une solution EXT RIEURE RECOMMAND moiti vinaigre moiti eau aide d loger les d p ts de min raux 3 Si le bloc vaporateur contient trop de d p ts de min raux le remplacer par un neuf 990 13 Replacer le 20 F 29 15 couvercle et le tuyau du distributeur a la position ad quate par dessus le bac du distributeur 10 F 23 20 4 Dans les endroits riches en min raux ou si