Home

Manual (english)

image

Contents

1. 4500Lux 1m 25 the system menu is built like described below this information Generally you can leave menus with ESC until you reach the highest control line With ENTER you can recall a function to set up the according values then you can change these values by using the UP DOWN buttons Always confirm your set up by using ENTER With ESC you can go back and leave this menu wd Gale pn Hei lc AGL L 3 2 DMX Control To set up your desired DMX address first of all push ESC then use the UP DOWN buttons until you see Addr in the display Now press ENTER to enter the menu Now the display shows Axxx In this case x stands for the set dmx address Now set up your own desired dmx address by using the UP DOWN buttons Leave the menu with the ESC button The fixture can be controlled by dmx 5 8 VARYTEC DMX Value Function Channel 1 0 255 Dimmer 0 100 2 0 255 Dimmer for Red 0 100 3 0 255 Dimmer for Green 0 100 4 0 255 Dimmer for Blue 0 100 5 0 255 Speed slow to fast 6 0 15 No Function 16 31 Scene mitR G B RG G 32 47 Scene mitG GB B RB R 48 63 Scene mitR B G RG G 64 79 Scene mitR G GB RGB G 80 95 Scene mitB BG RGB RG G 96 111 Color synchronized strobe 112 127 Color fade 128 143 Color change 144 159 Color change with strobe 160 175 Color Ramp down 176 191 Colour Ramp in 192 207 Colour triangular 208 223 Colour Glide 224 239 Soundi 240 255 Sound2 3 3 Automatic
2. VARYTEC User manual LED PAD 13 VARYTEC Table of contents 1 Safety instructions uuuuessssnnsssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnsnnnnnnnnnnsnnnsnnnnnnnnnennnnn 3 1 1 FOR SAFE AND EFFICIENT OPERATION skt tt Ek kk kE REESE RER E ERR REEL ERR ERR LEES ERNE REEL ERE 3 2 Technical Data 4 SON een ee ee eo een 4 Ile EE Ee 4 32 DMA CONTO EE 5 33 AUF OM ln Lee 6 934 OUI TO Dien e 6 3 5 Master Geesen egene ege eege eebe 7 SE VE IOUT FUNG EE 7 2 8 VARYTEC 1 Safety instructions e This device is suitable for indoor use only e All modifications to the device will void the warranty e Repairs are to carry out by skilled personnel only e Use only fuses of the same type and original parts as spare parts e Protect the unit from rain and humidity to avoid fire and electric shocks e Make sure to unplug the power supply before opening the housing 1 1 FOR SAFE AND EFFICIENT OPERATION Be careful with heat and extreme temperature Avoid exposing it to direct rays of the sun or near a heating appliance Not put it in a temperature bellow 32F 0 or e xceeding 104F 40U Keep away from humidity water and dust Do not place the set in a location with high humidity or lots of dust Containers with water should not be placed on the set Keep away from sources of hum and noise Such as transformer motor tuner TV set and amplifier To avoid placing on un stable loc
3. ation Select a level and stable location to avoid vibration Do not use chemicals or volatile liquids for cleaning Use a clean dry cloth to wipe off the dust or a wet soft cloth for stubborn dirt If out of work contact sales agency immediately Any troubles arose remove the power plug soon and contact with an engineer for repairing do not open the cabinet by yourself it might result a danger of electric shock Take care with the power cable Never pull the power cable to remove the plug from the receptacle be sure to hold the plug When not using the device for an extended period of time be sure to disconnect the plug from the receptacle 3 8 VARYTEC Important Damages caused by the disregard of this user manual are not subject to warranty The dealer will not accept liability for any resulting defects or problems Make sure the electrical connection is carried out by qualified personnel All electrical and mechanical connections have to be carried out according to the European safety standards 2 Technical Data Power supply Power consumption Current Sound to Light DMX512 connection Weight Measurements Maximum ambient temperature Maximum housing temperature Fuse Channel Number of LEDs 3 Operation 3 1 System men 100 240V 50 60Hz 60W 0 26A Via built in mic 3 Pin XLR 2 4 Kg 274x265 x 109mm 20 40 C 20 60 C F1A 250V 6 18 x 3W single colours LEDs 6R 6G 6B
4. mode To enter the automatic mode push the ESC button After that use the UP DOWN buttons until auto is shown in the display Push ENTER to enter the menu Now the display shows Aut x In this case x stands for 1 or 2 means the automatic programs 1 and 2 which you can choose by using the UP DOWN Button Push Enter to see the speed adjust menu The display shows SP x and x stands for a letter from 1 to 9 which is for adjusting the speed 3 4 Sound to Light mode to choose the sound to light mode go on as you read here Push the ESC button first Then use UP DOWN buttons until you see Soun in the display Push ENTER You can read Soux in the display and with the UP DOWN buttons you can choose between the 2 sound programs Push Enter to see the speed adjust menu The display shows SP x and x stands for a letter from 1 to 9 which is for adjusting the speed 3 5 Set up your fixed colour Push the ESC button first Then use UP DOWN buttons until you see CoLo in the display Push ENTER Now you can see Colx or AtF in the display If there is Colx the x stands for a number between 1 and 9 which stands for 9 different colors to be choosen by using the up down butions If you want to mix your own color then please push up down buttons until you see AtF in display then push ENTER When you have confirmed AtF you can choose between the following colors to set up from 1 to 255 Rxxx stands f
5. or red Gxxx stands for green Bxxx stands for Blue After setting up your colors confirm your choice with ENTER 3 6 Master Slave mode Push the ESC button first Then use UP DOWN buttons until you see SLav in the display Push ENTER Now the fixtures works in slave mode and copies exact the values from the master fixture For the connection of master fixture and slave fixture please use a standard dmx 3 pole XLR 110 Ohms cable Connect the male connector to the master and the female connector to the slave fixture Go on like this until all the fixtures you want to be connected are connected Set up your desired settings at the master and all the slaves will copy the functions of this fixture 3 7 Version number Push the ESC button first Then use UP DOWN buttons until you see VER in the display Push ENTER Now you can see the actual software version Leave the menu with ESC 4 DMX Cable info COMMON DMX512 OUT DM AST IN 3 PIN XLA 3 PIN XLR Figure 2 XLA Mate Socket ALN Temas SOCKER XLR Pin Configuration u i 1 Ground eg a onl o Ce bk Te i Gd ayok 2 Calg WW 1 Grung i Pin 1 Ground i I Fin 2 Gate Lenert regal ve il H ii I i 3 Hot S Hot Pin 6 Data Tue positive 2 ee a a a en Fa ee ae d 7 8 Importer B amp K Braun GmbH Industriestra e 1 D 76307 Karlsbad www bkbraun com info bkbraun com CE X RoHS m 2002 95 EC

Download Pdf Manuals

image

Related Search

Related Contents

  Denison Gold Cup - Ozark Fluid Power, Inc  Informations de propriété industrielle et commerciale  ThevoSiiS - Medicaleshop.com  Stopping Irrigation for Rain Events  CTS850 SDH/PDH Test Set User Manual Index 1 Check other  Operation Manual RM6E1 series    ADTRAN T200 H2TU-R User's Manual  evaluation de la politique du logement en ville nouvelle  