1. 6 1 Downward dimension Dimension A When the GT1555 main unit with no communication unit and the GT1555 is replaced with the GT1655 the following downward dimension Dimension A is required Table 6 1 Downward dimension Dimension A Unit mm GT15 model in use Replacement GT16 model Downward dimension Dimension A GT155o GT1555 VTBD GT165o GT1655 VTBD 46 or more 61 or more For the details refer to the external dimensions in the appendixes of the GT15 User s Manual SH 080528ENG or the GT16 User s Manual Hardware SH 080928ENG 6 2 Side dimension Dimension C When the GT1555 is replaced with the GT1655 changing the side dimension Dimension C is not required When the battery and or the CF card are used more space is required for installing or removing the battery and the CF card Therefore the following side dimension Dimension C is required Table 6 2 Side dimension Dimension C Unit mm GT15 model in use Replacement GT16 model Side dimension Dimension C GT155o GT1555 VTBD GT165o GT1655 VTBD 50 or more 20 or more 100 or more For the details refer to the external dimensions in the appendixes of the GT15 User s Manual SH 080528ENG or the GT16 User s Manual Hardware SH O80928ENG Version Print date Revision 7 May 2011 First edition Aa MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI
2. GT15 CFEX CO8SET Same as on the left Sound out unit GT15 SOUT Same as on the left External O unit GT15 DIOR Same as on the left GT15 DIO Same as on the left GT15 90XLTT GT16 90XLTT CL a a Since the GT15 backlight is not GT15 70SLTT GT16 70SLTT i Back light compatible with the GT16 main unit OTN TIOE the backlight cannot be used GT15 60VLTT GT16 60VLTT GT15 60VLTN GT16 60VLTN Not required The GT16 has the built in option function board as standard equipment Not required The GT16 has the built in option function board as standard equipment Not required The GT16 has the built in option function board as standard equipment Not required The GT16 has the built in option function board as standard equipment Not required The GT16 has the built in option function board as standard equipment Since the GT15 option function board GT15 MESB48M GT16 MESB is not compatible with the GT16 main unit the board cannot be used GT15 90PSCB GT15 90PSGB GT15 90PSCW GT15 90PSGW GT15 80PSCB GT15 80PSGB GT15 80PSCW Since the GT15 protective sheet is not GT15 80PSGW compatible with the GT16 main unit the sheet cannot be used PEE Since the GT15 protective sheet is not compatible with the GT16 main unit the sheet cannot be used GT15 FNB GT15 QFNB GT15 QFNB16M Option function board GT15 QFNB32M GT15 QFNB48M a MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCH
3. CC Link 10 55 Other cables ie Cede eee ene ee nee eee ee eee eee Semele Sake en ee ee Bae ee ee ee wee ee ee 10 6 Mounting intervals ieee eee eee ne en eee ee eee eee rede RE Re ERE Sd e ee Bae ee Be ee Ree ee 11 6 1 Downward dimension Dimension A ad ane ae Ree Be Re ee ee eee eee Be mee Re a Re Bm 11 6 2 Side dimension Dimension C otra eee eee eee ne ee ee eee E ae nee eo wee Oe Oe 11 Aa MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN TECHNICAL BULLETIN Issue No GOT A 0043 Page 2 11 Title Precautions when Replacing GT15 Models with GT16 Models Date of Issue Ver May 2011 Relevant Models GOT1000 Series 1 Requests for customers We released GT16 models with high functions and performance as alternative of GT15 models in August 2008 We highly recommend that you replace GT15 models with GT16 models for using new sophisticated features For the replacement models refer to Table 2 1 Recommended replacement GT16 models and precautions for replacement in Chapter 2 below 2 Selection of GOT The following table lists the recommended replacement GT16 models and the precautions for replacement For the details refer to the precautions in each chapter When you use a replacement GT16 model according to the model and its functions the required drawing software and the version o
4. Ethernet MELSEO Q1 MNG CRnD 700 v 6 5k Gateway M oa aM a Aa MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN TECHNICAL BULLETIN Issue No GOT A 0043 Page 4 11 Title Precautions when Replacing GT15 Models with GT16 Models Date of Issue Ver May 2011 Relevant Models GOT1000 Series 4 After setting I F set the IP address and others in Detail Setting BEE Controller Setting Controller Setting CH 1 MELSEC QnU DC Q CH 2 None Manufacturer MITSUBISHI A CH 3 None CH 4 None Controller Typ MELSEC QnU DC O17nD M NC DR CRnD 700 Sch Network Duplex Setting VF D Ethernet bia Routine Information Eb Gateway p Communication Detail Setting Gateway Server EE Gateway Client Property i GOT NET No Fig File Transfer F7 EAS al i Q Redundant GOT IP Address 192168 3 18 QD Station No Switchin IP Label Subnet Mask 255 255 255 0 Default Gateway 0 0 0 0 Ethernet Download Port No 5014 GOT Communication Port No 5001 Retry Times Startup Time Sec Timeout TimeSec Delay Time amp 10ms Driver By changing the Ethernet interface from the extension interface to the standard interface the configuration of the extension units may require changes Therefore change the controller setting overall 3 1 2
5. as on the left The GT16 has the built in battery as standard equipment GT1655 only Since the GT15 battery is not GT15 70ATT 98 GT15 70ATT 87 GT15 60ATT 97 GT15 60ATT 96 eenen GT15 60ATT 87 GT15 60ATT 77 GT15 50ATT 95W GT15 50ATT 85 Battery GT15 BAT compatible with the GT16 main unit the battery cannot be used 1 The slim model has limitation for combination with other units To use the slim model with the units for the functions including the external I O function the sound output function the printer function and the video RGB I O function use the following units GT15 ABUS A bus connection 1ch GT15 ABUS2 A bus connection 2ch GT15 QBUS Q bus connection 1ch GT15 QBUS2 Q bus connection 2ch Aa MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN GT11 50BAT N TECHNICAL BULLETIN Issue No GOT A 0043 Page 10 11 Title Precautions when Replacing GT15 Models with GT16 Models Date of Issue Ver May 2011 Relevant Models GOT1000 Series 2 Not applicable for the GT1655 3 To download monitor screen data and others from a personal computer to the GOT via the GOT built in RS 232 interface the cable must be replaced 4 For the printer models applicable to the GOT1000 series validated models refer to TECHNICAL BULLETIN GOT A 0010 List of Valid Devices Applicable
6. the extension interface to the standard interface the configuration of the extension units may require changes Therefore change the controller setting overall Aa MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN TECHNICAL BULLETIN Issue No GOT A 0043 Page 6 11 Title Precautions when Replacing GT15 Models with GT16 Models Date of Issue Ver May 2011 Relevant Models GOT1000 Series 3 2 Changing the utility call key setting While a user created screen is displayed touching a utility call key displays the main menu The utility call keys for the GT15 models excluding GT1595 are located at upper left and upper right corners on the GOT screen for simultaneous 2 point press The utility call key for the GT16 model is located at upper left corner on the GOT screen for only 1 point press The positions of the utility call Keys can be changed with the GOT utility GT Designer3 or GT Designer2 The following table shows the factory default position of the utility call keys for the GT15 models Modil Utility call key Factory default GT1595 Only 1 point press on the GOT screen upper left corner Utility call key One point press on the upper left corner Main menu 7 GT1585 Simultaneous 2 point press on the GOT screen upper left and upper right GT157o corners GT156o GT1550 Utili
7. 5 CHOME HIGASHI KU NAGOYA JAPAN
8. How to change the controller setting when using GT Designer2 Version2 1 When the GT15 model is connected via Ethernet Extend I F Setting is configured with one ranging from Extend I F 1 1st to Extend I F 2 3rd When Extend I F Setting is configured in Extend I F 1 1st System Environment ax System Environment System Settings J Project Title Standard I F Settings MV Use Communication Settings wi Auxiliary Setting GH No I F Driver ia System Information Standard L F 1 E x R5232 SO Host 0 YS aneren H Screen Switching i Security Standard I F 2 a 7 fu SB Host PC v Key Window us Dialog Window Extend I F Settings Switching Station No Extend L F 1 we Video RGB 1st Print Format Communication Settings GOT Setup Pa Language Switching 38 KANA KANJI Conversior Driver Ethernet MELSEO Q1 nNG GRnD 700 v Detail Setting Aa MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN TECHNICAL BULLETIN Issue No GOT A 0043 Page 5 11 Title Precautions when Replacing GT15 Models with GT16 Models Date of Issue Ver May 2011 Relevant Models GOT1000 Series 2 When the GOT type is changed from the GT15 model to the GT16 model Driver for Extend I F Setting in Communication Settings is changed to Bus Q Bus A QnA or MELSEC FX a
9. I CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN TECHNICAL BULLETIN Issue No GOT A 0043 Page 9 11 Title Precautions when Replacing GT15 Models with GT16 Models Date of Issue Ver May 2011 Relevant Models GOT1000 Series Table 4 1 Replacement models for communication units and options From the previous page Communication Unit model for GT15 Unit model for GT16 format option models models Except the GT1655 Since the GT15 environmental GT15 UCOV GT16 UCOV protection cover is not compatible with the GT16 main unit the cover cannot USB environmental be used protection cover GT1655 only Since the GT15 environmental GT11 50UCOV GT16 50UCOV protection cover is not compatible with the GT16 main unit the cover cannot be used a Since the GT15 protective cover for oil GT05 50PCO GT16 50PCO is not compatible with the GT16 main unit the cover cannot be used Stand Applicable to the GT16 When storing the project data in the CF card and using the data in the CF CF card card change the GOT type setting P GTOBMEMAGC 5 oomme 5 Sequiea o Wren 268 or more is required GTOBMEMABGC 5 viemory carg GT05 MEM ADPC Same as on the left adaptor Same as on the left Same as on the left Same as on the left Same as on the left Same as on the left Same as on the left Same as on the left Same as on the left Except the GT1655 Same
10. TECHNICAL BULLETIN Issue No GOT A 0043 Page 1 11 Title Precautions when Replacing GT15 Models with GT16 Models Date of Issue Ver May 2011 Relevant Models GOT1000 Series Thank you for your continued support of Mitsubishi Graphic Operation Terminal GOT We released GT16 models with high functions and performance as an alternative of GT15 models in August 2008 We highly recommend that you replace GT15 models with GT16 models for using new sophisticated features Table of Contents 1 Requests for customers etree cere Tr re er eee eT eee ee Tree er er re eee eT Cee Cee rer rT er er rere err 2 2 Selection of GOT Ter eT A A A Ce Teer T ere rT eer re Cre E re rer eee E N 2 3 Monitor screen data E E E rere eee E rer eer re ee rere ee ere rere re ree 3 3 1 Changing the controller setting Ethernet connection Only srr 3 3 1 1 How to change the controller setting when using GT Works3 Version 3 3 1 2 How to change the controller setting when using GT Designer2 Version2 4 3 2 Changing the utility Call key setting PCr ELT TeT rere A Teer ere rere 6 4 Communication Units and options ike Dehn ae Oe oo eee ee eee eee ace eee Dea kee T 5 Cables aera dee Dae Rae We ee De ee a ee Oe ee eee ena Reka eee ee 10 5 1 Bus connection cables E E eed A E whee A A A ee AET 10 5 2 RS 232 cables E E E A A eT A A ee 10 5 3 RS 422 485 cables E E ee E A E A E A A A A A 10 5 4 Network cables MELSECNET H MELSECNET 10 Ethernet CC Link IE
11. ccording to Controller Type in System Settings When MELSEC QnU DC Q17nD M NC DR or CRnD 700 is set for Type System Environment mef System Environment System Settings mg Project Title Standard I F Settings i Auxiliary Setting GH No I F Driver Ga System Information Standard L F 1 E v ji 0 Host PC v HH Screen Switching y Security Standard I F 2 a Hast PC ggeoseesoseeoosoosesoosecooesossseogeeosssoorpeosesosezzosesosserpeseossse iileocossososoossoosesocoscoscsosoeoececsoceosesoosesoscocoseesocsesonssF 45 Key Window a Dialog Window St RES LO x None SO Switching Station No Standard L F 4 ea we Video RGB Multimedia Extend I F Settings Print Format Extend I F 1 CH Ne ER Communication Settings GOT Setup Ist f E Bus Q v Detail Setting Language Switching 2nd 1 FE se KANA KANJI Conversior 629 Clock Setting 3rd fo v None 7 TI Cteavtiun lara 3 In Communication Settings set O for CH No of Extend I F 1 1st in Extend I F Setting and set 4 for CH No of Standard F 4 in Standard I F Settings Driver is automatically changed j System Environment System Environment System Settings tm Project Title Standard I F Settings i Auxiliary Setting GH No I F Driver MV Use Communication Settings Ga System Information Standard L F 1 E v RS23 Host PC v jil Settir H Screen Switching IE Security S
12. ernet cable is changed check the wiring of the cable 5 5 Other cables The following cables for the GT15 model are available for the GT16 model Printer cable CRT connection cable Coaxial cable for displaying video image Nine core composite cable for the RGB display screen Connection cable for the Non Mitsubishi FA devices Conversion cable for connecting the external I O unit Analog RGB cable Data transfer cable RS 232 USB Aa MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN TECHNICAL BULLETIN Issue No GOT A 0043 Page 11 11 Title Precautions when Replacing GT15 Models with GT16 Models Date of Issue Ver May 2011 Relevant Models GOT1000 Series 6 Mounting intervals When the GT15 model is replaced with the GT16 model only the dimensions A and C are changed among the mounting intervals Dimensions A to F in the below figure The following explains the precautions for the mounting intervals For intervals required for each product refer to the mounting intervals in the catalog In addition when mounting a communication unit or option unit on the GOT to use the multi channel function refer to the user s manual of each communication unit and or option for the dimensions E and F f Other device or control panel Thickness Y 2 to 4mm We
13. f the software differ For the details refer to the catalogs the user s manuals or the MELFANSweb website and prepare the appropriate drawing software Table 2 1 Recommended replacement GT16 models and precautions for replacement GT15 models in use Recommended GT16 models Panel cut Applicable software version Applicable software version version for replacement compatibility o Compatible Not GT Works3 GI Designer2 compatible GT1595 GT1695 GT1695M XTBA GT1595 XTBD GT1695M XTBD GT1585 GT1585V STBA GT1685 GT1685M STBA 1 o GT1685M STBD 1 Ver1 01B or later Ver2 90U or later GT1585 STBA GT1685M STBA 1 o E STBD GT1685M STBD 1 GT1570 GT1670 GT1675M STBA 1 oo GT1575V STBD GT1675M STBD 1 o CEE STBA GT1675M STBA 1 oo ESTEN eTie7sMm sTeD 1 od a TSE TBA VTBA GT1675M VTBA 1 gt o See VTBD GT1675M VTBD 1 o CEE A VNBA GT1675 VNBA 1 oo rGTIS7S NED GT1675 VNBD 1 renn T IEEE VNBA GT1672 VNBA 1 oo seer VNBD Pah CD o ooo Jne VNBA GT1662 VNBA 1 VNBA 1 Sy aeeoo Vert_ 17T or later pramo aa VNBD GT1662 VNBD 1 i 2 GT1662 VNBD 1 o Not supported GT1550 GT1555 VTBD_ GT1650 GT1655 VTBD 1 gt o Ver1 28E or later GT1555 QTBD No replacement GT16 aa Use the GT1555 QaBD continuously GT1555 QSBD GT1550 QLBD 1 Since the touch panel type is the analog resistive f
14. for GOT1000 Series on the MELFANSweb website To use the serial printer GT Works3 with version 1 15R or later is required 5 GOT BootOS version 05 09 00AF or later supported If you use the GOT with the BootOS whose version is earlier than 05 09 00AF installed install the latest BootOS on the GOT by using GT Designer3 with version 1 15R or later 5 Cables 5 1 Bus connection cables The bus connection cables for the GT15 model are available for the GT16 model 5 2 RS 232 cables The RS 232 cables for the GT15 model are available for the GT16 model 5 3 RS 422 485 cables The RS 422 485 cables for the GT15 model are available for the GT16 model When the GT15 RS4 9P or the GT15 RS2T4 9P for the GT15 model is used and the GT15 model is replaced with the GT16 model with the GOT built in interface the GI16 CO2R4 9S RS 422 connector conversion cable is required When the GI15 RS2T4 25P for the GT15 model is used and the GT15 model is replaced with the GT16 model with the GOT built in interface the GT16 CO2R4 25S RS 422 connector conversion cable is required 5 4 Network cables MELSECNET H MELSECNET 10 Ethernet CC Link IE CC Link The network cables for the GT15 model are available for the GT16 model For the Ethernet connection the Ethernet communication unit for the GT15 is replaced with the GT16 built in Ethernet interface The Ethernet communication unit cannot be mounted on the GT16 Since the connection location of the Eth
15. ilm only one point can be touched When the simultaneous 2 point press is required use the GT15 model continuously For the precautions for replacement refer to each chapter as shown below Monitor screen data Chapter 3 Communication units and options Chapter 4 Cables Chapter 5 Mounting intervals Chapter 6 MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN TECHNICAL BULLETIN Issue No GOT A 0043 Page 3 11 Title Precautions when Replacing GT15 Models with GT16 Models Date of Issue Ver May 2011 Relevant Models GOT1000 Series 3 Monitor screen data The monitor screen data used with the GT15 model can also be used with the GT16 model by converting the GOT type on the applicable drawing software 3 1 Changing the controller setting Ethernet connection onl When the GT15 model is connected via Ethernet change the controller setting for the GT16 model In the Ethernet setting though the extension interface is specified for the GI15 model specify the standard interface for the GT16 model 3 1 1 How to change the controller setting when using GT Works3 Version1 1 When the GT15 model is connected via Ethernet the extension interface among options ranging from Extend I F 1 1st to Extend I F 2 3rd is set for I F When Extend I F 1 1st is set for I F Con
16. s on the left Use the unit dedicated to the CC Link ver 2 network system in the mode for the CC Link ver 1 network system mode GOT built in Ethernet The Ethernet communication unit Ethernet connection GT15 J71E71 100 ee cannot be mounted on the GT16 main unit Serial Multi drop GTOLRS4M RS4 M Same as onthe left Same as onthe left on the left connection Ce PRN Same as on the left PictBridge compatible printer 4 Printer interface GT15 RS2 9P Same as on the left n Serial printer 4 GOT built in interface Same as on the left 3 GT15V 75V4 75V4 GT16M V4 sd V4 l o Video RGB IRANL 75R1 SuN o R2 Since the G1 1 UnIEIS NOt compatible comedia GT15V 75V4R1 GT16M V4R1 with the GT16 main unit the unit cannot be used GT15V 75ROUT GT16M ROUT CC Link connection A746 76 161 BR13 Z GT15 J61BT13 MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN TECHNICAL BULLETIN Issue No GOT A 0043 Page 8 11 Title Precautions when Replacing GT15 Models with GT16 Models Date of Issue Ver May 2011 Relevant Models GOT1000 Series Table 4 1 Replacement models for communication units and options From the previous page Communication Unit model for GT15 Unit model for GT16 format option models models CF card unit GT15 CFCD Same as on the left CF card extended unit
17. tandard L F 2 j 7 fus z Host PG v Key Window Standard I F 3 n vi FR one ve Dialog Window Switching Station No ee Video RGB 4 After setting Standard I F Settings set the IP address and others in Detail Setting l System Environment Communication Detail Settings as Environment Use Communication Settings Driver Ethernet MELSEC Q17nNC CRnD 700 System Settings i Project Title Standard L F A GOT NET No i o Mi Auxiliary Setting o I F Driver Ga System Information Standard L F 1 9 v fF 28232 Host PC Ega due lme a EL Screen Switching GOT IP Address fi 92 168 3 18 Setting Security Standard L F 2 fa J Host PC S Key Window Standard L F 3 ji 122 4 i r i 0 4227485 N i Ue Dialog Window 7 one 7 pn vee Switching Station Na aei fi zi Ethernet Ethernet MELSEC Q1 inNC CRnD 700 Ethernet Download Port No 5014 we Video RGB Multimedia Extend I F Settings Subnet Mask 255 255 255 0 ren ormat Extend I F 1 Driver Default Gateway paoa Communication Settings z3 GOT Setup ist None z Da GOT Port No A Language Switching 2nd None a Communication 5001 KANA KANJI Conversior z i FA Clock Setting ard C Retry p E Times E Startup Logo Startup Time g H Sec Extend L F 2 i xten Driver Timeout Time g Sec ist one SSCS etn r ne N Delay Time 0 amp 10 ms None o cancel a oeei By changing the Ethernet interface from
18. troller Setting Controller Setting D CH 1 MELSEC QnU DC Q CH 2 None Manufacturer MITSUBISHI Q CH 3 None CH 4 None Controller Type MELSEC QnU DC O17nD M NG DR CRnD 700 v Sch Network Duplex Setting D Ethernet Ef Routing Information Driver Ethernet MELSEC Q17nNC CRnD 700 v Sh Gateway ae LF Extend L F 14 st 2 When the GOT type is changed from the GT15 model to the GT16 model I F is not changed and Driver is changed to Bus Q Bus A QnA or MELSEC FX according to Type When MELSEC QnU DC Q17nD M NC DR or CRnD 700 is set for Type Controller Setting Controller Setting D CH 1 MELSEC QnU DC QD CH 2 None Manufacturer MITSUBISHI v CH 3 None QD CH 4 None Controller Type MELSEC OQnU DC Q17nD M NC DR GRnD 700 v Sch Network Duplex Setting D Ethernet I F Extend I F 1 4st z Routing Information f Driver Bus Q 7 oS Gateway 3 In the controller setting set I F to Standard I F Ethernet Multi Driver is automatically changed Gontroller Setting Controller Setting A CH 1 MELSEC QnU DC Q CH 2 None Manufacturer MITSUBISHI v QD CH 3 None CH 4 None Controller Type MELSEC QnU DO Q17nD M NG DR GRnD 700 v 5 Network Duplex Setti Sch a anh Sa LF Standard I F Ethernet Multi v Ef Routine Information Driver
19. ty call key Simultaneous 2 point press Main menu Only 1 point press on the GOT screen upper left corner Utility call key One point press on the upper left corner Main menu j Aa MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN TECHNICAL BULLETIN Issue No GOT A 0043 Page 7 11 Title Precautions when Replacing GT15 Models with GT16 Models Date of Issue Ver May 2011 Relevant Models GOT1000 Series 4 Communication units and options When checking whether the communication units and the options for the GI15 models can be used for the GT16 main unit refer to the following Table 4 Replacement models for communication units and options Communication Unit model for GT15 Unit model for GT16 Sermatoption meds mode EEEE Slim model 1 Slim model 1 e Slim model 1 Slim model 1 a GT15 RS4 9P GOT built in RS 422 485 The conversion cable interface GT 16 CO2R4 9S is required Same as on the left 2 as on the left 2 eee GT 16 CO2R4 9S is required Same as on the left 2 as on the left 2 GT15 RS2T4 25P The conversion cable fetes GT 16 CO2R4 25S is required MELSECNETN connection MELSECNETI10 moet a vig Al connection repeal ada MELSECNETIB connection CC Link Controller GT15 J71GP23 SX Same as on the left connection GT15 J61BT13 Same a