Contents
1. Front Panel 1 Voltage and Ammeter LED Display 2 Overload LED Indicator Overload Constant Current Limiting and Short Circuit Protection 3 Output Voltage Control Knob Control Both Main and Auxiliary Output 4 Power ON OFF Switch 5 Power ON OFF LED 6 Auxiliary Output Terminal max 5 A for 1693 max 3 A for 1694 Note Please see Section 5 2 for more details on using both main and auxiliary output terminals together 7 4 2 7 8 9 10 11 12 Rear Panel Figure 2 Rear Panel Main Output Terminal rated 60 A for 1693 30 A for 1694 Note Please see Section 5 2 for more details on using both main and auxiliary output terminals together Remote Sensing Terminal Analog Remote Control Terminal Analog Remote Control ON OFF Switch Cooling Fan Air Intake Grille AC Input Plug 5 Operating Instructions Safety Precautions e Never short the remote sensing terminal e This power supply is for indoor use only e Donotexpose the power supply to sun high humidity or dusty environments e Neverremove the metal cover of the power supply while AC power is connected e Nevertouch the unit when your hands are wet e Never block the ventilation slots and cooling fan air intake window e Neverattempt to repair the power supply Incorrect reassembly may result in a risk of electric shock or fire e Neveruse the power supply for a load requiring higher current than the design
2. ga a YD Fie WIRY BK Im 1693 1694 Switching DC Power Supply INSTRUCTION MANUAL 1 Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be observed during all phases of operation service and repair of this instrument Before applying power follow the installation instructions and become familiar with the operating instructions for this instrument GROUND THE INSTRUMENT To minimize shock hazard the instrument chassis and cabinet must be connected to an electrical ground This instrument is grounded through the ground conductor of the supplied three conductor ac power cable The power cable must be plugged into an approved three conductor electrical outlet Do not alter the ground connection Without the protective ground connection all accessible conductive parts including control knobs can render an electric shock The power jack and mating plug of the power cable meet IEC safety standards DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE Do not operate the instrument in the presence of flammable gases or fumes Operation of any electrical instrument in such an environment constitutes a definite safety hazard KEEP AWAY FROM LIVE CIRCUITS Instrument covers must not be removed by operating personnel Component replacement and internal adjustments must be made by qualified maintenance personnel Disconnect the power cord before removing the instrument covers and
3. replacing components Under certain conditions even with the power cable removed dangerous voltages may exist To avoid injuries always disconnect power and discharge circuits before touching them DO NOT SERVICE OR ADJUST ALONE Do not attempt any internal service or adjustment unless another person capable of rendering first aid and resuscitation is present DO NOT SUBSTITUTE PARTS OR MODIFY THE INSTRUMENT Do not install substitute parts or perform any unauthorized modifications to this instrument Return the instrument to B amp K Precision for service and repair to ensure that safety features are maintained WARNINGS AND CAUTIONS WARNING and CAUTION statements such as the following examples denote a hazard and appear throughout this manual Follow all instructions contained in these statements A WARNING statement calls attention to an operating procedure practice or condition which if not followed correctly could result in injury or death to personnel A CAUTION statement calls attention to an operating procedure practice or condition which if not followed correctly could result in damage to or destruction of parts or the entire product WARNING WARNING CAUTION CAUTION Do not alter the ground connection Without the protective ground connection all accessible conductive parts including control knobs can render an electric shock The power jack and mating plug of the power cable meet IEC safety s
4. BEES Cor ESPERE SH 22820 Savi Ranch Parkway Yorba Linda CA 92887 www bkprecision com 2011 B amp K Precision Corp Printed in Hong Kong v041211
5. GertifiCatiOn oc cede eee cote de eate toute eee e S AERAR 20 9 Service Information eoe tote e ees conde eee pev e SERIE AEE 21 10 Limited One Year W rranty nienean ia nnne nnns nnn 22 2 Introduction B amp K Precision models 1693 and 1694 switching mode DC power supplies provide high current output in a lightweight and compact package It is suitable for a variety of uses especially for powering DC operated mobile radio equipment on the bench These 900W power supplies provide a variable voltage output from 1 V to 15 V at 60 A model 1693 or from 1 V to 30 V at 30 A model 1694 In addition a remote sensing terminal is available for use to compensate for voltage drops due to resistances from load leads The output voltage level can also be externally controlled via an analog remote control terminal Switching mode power supplies have the advantage of being lightweight and high in efficiency when compared to traditional linear mode power supplies The efficiency can exceed 85 under optimal conditions Bright 3 digit LED displays give an accurate and highly readable indication of settings Features e Up to 60A output current e Lightweight and compact e Dual3 digit LED displays e Remote sense terminal e Analog remote control via external voltage source or variable resistor e Current foldback circuitry with illuminated indicator prevents overloading the power supply e Overtemperature protection circuitry e Overvoltage protection e Fron
6. fuses as follows 1 Unplug the power cord from the rear of the instrument 2 Use a screwdriver to remove case cover of power supply 3 Locate PCB near the power input receptacle where the fuses are clipped in designated as F1 and F2 and replace blown fuses 16 Cooling Fan Power input receptacle Figure 8 Fuse Location 6 3 Instrument Repair Service Because of the specialized skills and test equipment required for instrument repair and calibration many customers prefer to rely upon B amp K Precision for this service We maintain a network of B amp K Precision authorized service agencies for this purpose To use this service even if the instrument is no longer under warranty follow the instructions given in the Warranty Service section of this manual There is a nominal charge for instruments out of warranty 17 7 Specifications 1693 1694 Output Variable Output Voltage 1 15 V 1 30 V Rated Main Output Current 60 A 30A Rated Auxiliary Output Current 5A 3A Ripple and Noise 40 mVpp Load Regulation 0 1 5 mV Line Regulation 0 05 3 mV Meter Type amp Accuracy Voltmeter 3 digit LED display 1 1 count Ammeter 3 digit LED display 1 1 count Other Input Voltage 100 240 VAC 50 Hz 60 Hz Dynamic Power Factor Correction gt 0 97 at optimal load Efficiency gt 8596 Cooling Method Vari
7. phone number and description of problem 21 10 Limited One Year Warranty B amp K Precision Corp warrants to the original purchaser that its products and the component parts thereof will be free from defects in workmanship and materials for a period of one year from date of purchase B amp K Precision Corp will without charge repair or replace at its option defective product or component parts Returned product must be accompanied by proof of the purchase date in the form of a sales receipt To obtain warranty coverage in the U S A this product must be registered by completing a warranty registration form on our website www bkprecision com within fifteen 15 days of purchase Exclusions This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs The warranty is void if the serial number is altered defaced or removed B amp K Precision Corp shall not be liable for any consequential damages including without limitation damages resulting from loss of use Some states do not allow limitations of incidental or consequential damages So the above limitation or exclusion may not apply to you This warranty gives you specific rights and you may have other rights which vary from state to state B amp K Precision Corp 22820 Savi Ranch Parkway Yorba Linda CA 92887 www bkprecision com 714 921 9095 22 Page intentionally left blank BK EACH NC E
8. able speed thermostatically controlled fan 18 1693 1694 Overload Constant Current Limiting Short Circuit OTP Protections Overtemperature Protection and OVP Overvoltage Protection Special Features Remote control and remote sensing Operating 32 F to 104 F 0 C to 40 C lt 80 R H Temperature Storage Temperature 5 F to 158 F 15 C to 70 C lt 85 R H Dimension 8 66 x 4 33 x 14 17 220 x 110 x 360 mm WxHxD Weight 12 8 Ibs 5 8 kg Supplied Accessories Power cord instruction manual remote control connector Note All specifications apply to the unit after a temperature stabilization time of 15 minutes over an ambient temperature range of 23 C 5 C Specifications are subject to change without notice To ensure the most current version of this manual please download the latest version here http www bkprecision com search manual 1694 For current up to date product information please visit www bkprecision com 19 8 Certification CE Compliant CE Declaration of Conformity The power supply meets the requirements of 2006 95 EC Low Voltage Directive and 2004 108 EC Electromagnetic Compatibility Directive Low Voltage Directive EN60950 o Safety requirements for electrical equipment for measurement control and laboratory use EMC Directive EN 55022 o Electrical equipment for measurement control and laboratory
9. ad is disconnected and the power supply is OFF before continuing to the next step Otherwise power supply may be damaged d Plug the remote connector plug into the remote control terminal of the power supply e Secure the remote connector plug to the terminal socket by locking connector ring Figure 6 13 Connector ring Figure 6 Connector Ring Then you can choose either method A or B below to use the analog remote control feature Method A Using an External Variable DC Voltage Source A variable external voltage source of 0 to 5 V is fed into the analog remote control terminal to adjust the output voltage level of both Main and Auxiliary outputs WARNING Do not input higher than 5 V otherwise the overvoltage protection OVP will be triggered 1 Make sure the load is disconnected and the power supply is OFF 2 Only use wires from pins 2 and 3 Connect pin 2 to positive polarity of the external voltage source and pin 3 to negative polarity of the external voltage source 3 Turn the remote control ON OFF switch to ON position 4 Switch on the power supply 5 Vary the external input voltage from 0 to 5 V to check and verify the full output voltage range of the power supply 6 Switch off the power supply 14 Method B Using a5 kQ Variable Resistor 1 Make sure the load is disconnected and the power supply is OFF 2 Prepare a5 kQ variable resistor and connect wires from pins 1 2 and 3 as show
10. cal WEEE collection facilities in the disposition of this product and otherwise observe all applicable requirements Contents l Safety SUMMANY ze nth cele et Bats n ER 1 20 AOO UUE ON eiar E M M 5 3 rstallatiOnu aient te cuite A EA e ela ae ge N a a 6 3 1 Initial Inispectioniss etr tener e aaa sees 6 3 2 Input Power Requirements eeeeeeeseeeeee enne 6 A Controls and Indicators essen ener 7 4 1 Front Panel 5c ee reete re ern ene endete eure 7 4 2 Rear Panels isa tei de t edere tette ette ts 8 5 Operating Instructions ett ette teste estie een cond ee fee ttes 9 5 1 Instrument Hook Up ccesescccccecsesessaecececssessesesaeseesesseesesneaeeeeeens 10 5 2 Using Both Main and Auxiliary Outputs eese 11 5 3 Remote Sensing ueteri tete ste 11 5 3 1 COMME CTON pm 11 5 3 2 Disconnection oer eR poetae eR ve eh ete E ege aa aste EE 12 5 4 Remote Control 4 reete nadie nd ena aea aaa 12 5 4 1 Voltage Remote Control eese 12 5 4 2 Enable and Disable the Output esseeeeeeeee 15 6 Maintenance sk ats eere dr ttbi ee ey vues Penta a hare EUER 16 6 1 When the Unit is Not Turning On sese 16 6 2 Fuse R placetrient uttter tet a eaae aaa eR 16 6 3 Instrument Repair Service ueeeeeeseeeeeeseee eene 17 Zo Specifications aeta trat est teer ure Or DER auia ut 18 8
11. ed value otherwise it may damage the power supply e Place the power supply on a flat surface with sufficient clearance and dry dust free surroundings for ventilation This series has two models with different output voltage range and current Make sure you have purchased the correct one Model Number Output Voltage Range Total Rated Current 1693 1 15V 60A 1694 1 30V 30A Table 1 Models 5 1 Instrument Hook Up 1 Check the rating label of the power supply and make sure it complies with your AC mains voltage Connect the power supply to the AC mains using the provided power cord CAUTION The AC input is double pole fusing 2 Ifyou do not use the analog remote control feature make sure the remote control ON OFF switch on the rear panel is in the OFF position For analog remote control procedures please refer to Section 5 4 3 Switch on the power supply and the power ON OFF LED should light up in green Then adjust the output voltage to the desired voltage and switch off the power supply 4 Ifyou are using remote sense connect as described in Section 5 3 Otherwise skip to the next step 5 Connect the positive polarity of the device being powered to the red terminal of the power supply 6 Connect the negative polarity of the device being powered to the black terminal of the power supply 7 Switch on the power supply first and the LED indicator should light up in green 8 Switch on the equipment and
12. n in Figure 7 To Pin 2 5kohm Variable Resistor Figure 7 Variable Resistor Connection 3 Turn the remote control ON OFF switch to ON position 4 Switch on the power supply gy Adjust the 5 kQ variable resistor from one end to the other to check and verify the full output voltage range of the power supply 6 Switch off the power supply 5 4 2 Enable and Disable the Output You can use pins 7 and 8 to remotely control the OUTPUT ON OFF a Open pins 7 and 8 if you want to ENABLE the output by default b Short pins 7 and 8 if you want to DISABLE the output 15 6 Maintenance 6 1 Whenthe Unit is Not Turning On Check if the power ON OFF switch is turned ON If not then check the power cord Please make sure that the power cord is properly connected to the unit Please also check the main switch and ensure that the AC supply at your site is the same as the one mentioned at the rear chassis of the unit Check for a blown fuse 6 2 Fuse Replacement If the fuse blows the LED will not light and the instrument will not operate Replace only with the correct value fuse Refer to table below for fuse value and type There are two identical fuses located internally on a PCB near the power input receptacle Line Voltage Fuse Type 100 240 VAC 20 A 250 V 3AB ceramic tube fast blow Table 2 Fuse Table CAUTION Never remove the metal cover of the power supply while AC power is connected Replace
13. rrent Aux Main is 30A 5 3 Remote Sensing WARNING Never short the remote sensing terminal Never connect the remote sensing terminal in reverse polarity Always disconnect the remote sensing terminal first The 1693 and 1694 both provide a remote sensing terminal to help compensate for voltage drops due to load leads 5 3 1 Connection 1 Make the power connections between power supply and equipment 11 2 Check and make sure the power connections are secure 3 Then make connections between Remote Sensing and equipment Figure 3 shows typical connection between power supply and device for remote sense operation Remote Sensing Output Power Supply Device Figure 3 Remote Sense Connection The remote sensing wire should be at least 22AWG wire size 5 3 2 Disconnection WARNING Wrong disconnect sequence will damage the power supply 1 Disconnect the remote sensing connections 2 Disconnect the power connections between the power supply and equipment 5 4 Remote Control 5 4 1 Voltage Remote Control Set up the provided remote connector plug a Remove the pin plug of the remote control connector plug by removing the screw as shown in Figure 4 12 Remove the screw Rotate the pin plug Remove the pin plug Figure 4 Remote Control Connector b Solder3 wires 22AWG to pins 1 2 and 3 of pin plug as shown in Figure 5 Figure 5 Pin Numbers c Make sure the lo
14. t panel auxiliary output 3 Installation 3 1 Initial Inspection This unit is tested prior to shipment It is therefore ready for immediate use upon receipt The initial physical inspections should be made to ensure that no damage has been sustained during shipment Inspect the packing box on receipt for any external damage If any external damage is evident remove the instrument and visually inspect its case and parts for any damage If damage to the instrument is evident a description of the damage should be noted on the carrier s receipt and signed by the driver or carrier agent Save all shipping packaging for inspection Forward a report of any damage to the agent through which the unit is procured Retain the original packing in case subsequent repackaging for return is required Use of the original packing is essential After the mechanical inspection verify the contents of the shipment The items included with the instrument are e Power cord e Instruction manual e Remote control connector If the contents are incomplete or if the instrument does not pass the specification acceptance tests notify the local service center 3 2 Input Power Requirements The power supply has a universal input and can operate in any country that uses a mains voltage within 100 240 VAC 50Hz 60Hz 4 Controls and Indicators 4 1 Front Panel POWER AUX OUTPUT MAXIMUM SA SWITCHING MODE DC REGULATED POWER SUPPLY Figure 1
15. tandards To avoid electrical shock hazard disconnect power cord before removing covers Refer servicing to qualified personnel Before connecting the line cord to the AC mains check the rear panel AC line voltage indicator Applying a line voltage other than the indicated voltage can destroy the AC line fuses For continued fire protection replace fuses only with those of the specified voltage and current ratings This product uses components which can be damaged by electro static discharge ESD To avoid damage be sure to follow proper procedures for handling storing and transporting parts and subassemblies which contain ESD sensitive components SAFETY SYMBOLS N Certification This symbol on an instrument indicates that the user should refer to the operating instructions located in the manual We certify that this product met its published specifications at time of shipment from the factory Compliance Statements Disposal of Old Electrical amp Electronic Equipment Applicable in the European Union and other European countries with separate collection systems This product is subject to Directive 2002 96 EC of the European Parliament and the Council of the European Union on waste electrical and electronic equipment WEEE and in jurisdictions adopting that Directive is marked as being put on the market after August 13 2005 and should not be disposed of as ar unsorted municipal waste Please utilize your lo
16. the LED indicator should still remain green 9 You can now operate the equipment When an operation is finished switch off the equipment first and then switch off the power supply 10 When disconnecting the power supply from the unit disconnect the remote sensing wire first and then disconnect the output cables Note Steps 2 and 4 explain how to use the special features analog remote control and remote sense You can use both features at the same time or separately 10 5 2 Using Both Main and Auxiliary Outputs The 1693 and 1694 both have a main and auxiliary output that can be used separately or together The voltage control knob will adjust the output voltage for both of these output terminals and they will output the same voltage When using both the main and auxiliary outputs together the power supply will automatically total the currents supplied to both terminals up to the current limit of the power supply and show the total current on the display For example setting the voltage output for model 1693 1 15 V 0 60 A to 15 V would output 15 V at both the main and auxiliary terminals A total of 60 A can be drawn between the two terminals If there is a 5 A load at the auxiliary terminal the most current you can draw from the main output is 55 A If the power supply exceeds its maximum rated current at any time the overload LED will light Note 1693 Total rated current Aux Main is 60 A 1694 Total rated cu
17. use 20 9 Service Information Warranty Service Please go to the support and service section on our website at www bkprecision com to obtain an RMA Return the product in the original packaging with proof of purchase to the address below Clearly state on the RMA the performance problem and return any leads probes connectors and accessories that you are using with the device Non Warranty Service Please go to the support and service section on our website at www bkprecision com to obtain an RMA Return the product in the original packaging to the address below Clearly state on the RMA the performance problem and return any leads probes connectors and accessories that you are using with the device Customers not on an open account must include payment in the form of a money order or credit card For the most current repair charges please refer to the service and support section on our website Return all merchandise to B amp K Precision Corp with pre paid shipping The flat rate repair charge for Non Warranty Service does not include return shipping Return shipping to locations in North America is included for Warranty Service For overnight shipments and non North American shipping fees please contact B amp K Precision Corp B amp K Precision Corp 22820 Savi Ranch Parkway Yorba Linda CA 92887 www bkprecision com 714 921 9095 Include with the returned instrument your complete return shipping address contact name