CB-NAP-7000D

image

Contents

1. Fig 3 16 NAP7000D User Manual Version 1 0 52 3 5 Tutorial 5 One CB 7012 CB 7017 CB 7021 and CB 7044 module with Excel Working CB 7000 Module one CB 7520 and One CB 7012 CB 7017 CB 7021 and CB 7044 Wording Software NAP7000D and Excel Function To demonstrate how to control a remote control network consist of CB 7012 CB 7017 CB 7021 and CB 7044 Here the CB 7021 and CB 7044 control by Excel Working Steps Step 1 Setting the configurations for these four CB 7000 modules as Fig 3 17 shown Please adjusting the baud rate and module address according to your CB 7000 module configuration NAP7000D User Manual Version 1 0 53 1205 1947 7021 3 3 7017 4 4 7044 7 7 115200 9600 38400 3600 Other Information Analog Input Service excel Topic sheet1 1 1 Analog Input Channels FF Service excel Topic sheetl1 Item r2cl Fig 3 17 Step 2 Activating Excel Then entering a value in Al and A2 cell For examples 2 34 in A1 It means the analog output voltage of CB 7021 will be 2 34V Then typing 15 in A2 It means the digital output value of CB 7044 is F hex Please referring Fig 3 18 NAP7000D User Manual Version 1 0 54 FI NAP7000D Microsoft Excel Book TAD 0 MAAD 2 DDE Server 388 7 2 1 u ype Dec Hex MI Other Intormation E 7012 D 115200 Analog Inpu
2. M L L m Fig 2 12 The main window for NAP7000D when completing a setting The user can move the mouse point to the checked 0 Then press the right button of mouse to retrieve the setting information And a information window would be toggled on as Fig 2 13 shown Again pressing the right button may toggle off the information window NAP7000D User Manual Version 1 0 20 Fig 2 13 Toggle on the information window NAP7000D User Manual Version 1 0 21 2 Setting the CB 7017 CB 7018 Stepl Check a ConvN here means 0 to 31 to start the setting CB 7000 module configuration In this example the Conv8 is checked Step 2 Select the desired module type as Fig 2 10 shown method 1 or method 2 In this case please select 7017 or 7018 In this examples the 7017 is selected Step 3 After selecting 7017 a window titled 7017 7018 Channel selection will pop up as Fig 2 14 shown The user can check the desired input channel to received analog input data Or just push Select All button to select all eight channels After check the desire channels then push OK button to complete the channel selection Or pushing Cancel button to cancel the channel selection Ele COM Port Search Run DDE Display Establish Conversation x COM Port DDE Server Conversations 2 E ConvO Conv8 Convi6 Conv24
3. 5 Output ReadBack Output value 00 000 Value To output value via DDE link Service excel Topic sheet Output via Item 1 1 DDE link The Found Out ene Fig 3 11 NAP7000D User Manual Version 1 0 48 Step 2 Activating Excel Then entering a value in A1 cell for examples 1 23 as shown in Fig 3 12 It means the output voltage of CB 7021 will be 1 23V Preble 12 Al 123 1 23 Fig 3 12 NAP7000D User Manual Version 1 0 49 Step 3 Click Run DDE menu to start NAP7000D function call Step 4 Trying to change the value of A1 cell of Excel then the value in first conversation channel may vary according to the value in A1 cell of Excel as shown in Fig 3 14 Microsoft Excel NAP7000D User Manual Version 1 0 50 3 4 Tutorial 4 One CB 7012 CB 7017 CB 7021 and CB 7044 module Working CB 7000 Module one CB 7520 and One CB 7012 CB 7017 CB 7021 and CB 7044 Working Software NAP7000D Function To demonstrate how to control a remote control network consist of CB 7012 CB 7017 CB 7021 and CB 7044 in different baud rate speed Working Steps Step 1 Setting the configurations for these four CB 7000 modules as Fig 3 15 shown m NAP7000D File COM Port Search Run DDE Display Establish C
4. Rp RED FAD IAD BHD MEW j aon 6th 7th 8th 9th 10th 11th 12th 13th 6 14th 15 8 16th 9 gt nN Sheet Sheet2 NAP7000D User Manual Version 1 0 4 3 674 0 004 0 004 0 003 1 518 0 003 0 003 0 003 Microsoft Excel zi ul se se 9 Fig 3 6 Passing data from NAP7000D to Excel NAP7000D User Manual Version 1 0 45 Further when needing analysis the data of each channel of CB 7017 Typing MID function in a cell of Excel For example the channel 0 s value is retrieved in A2 by keying MID A1 1 7 as Fig 3 7 shown DDE Conversation Channel 2nd 3rd 86 RED RED HAD ERO IAD BHO MEW 4th 5th 6th 7th 8th 9th 10th 11th 12th 13th 14th 15th BL etu ice ESOT SSS TST ald Fig 3 7 To retrieve channel 0 s value into a cell by mean of MID function The retrieved value shown as Fig 3 8 DDE Conversation Channel x 1st 3 674 0 005 0 004 0 004 1 518 0 003 0 003 0 004 17th 2nd Microsoft Excel 2 3rd BRE EE REY BAD AO IAD BAO RAD 2 z ul sal 5th 6th 7th 8th 10th 11th Fig 3 8 The retrieved value displayed in the cell NAP7000D User Manual Version 1 0
5. Nap 7000d 2 Windows NT Explorer ug Administrative Tools Common ug Microsoft Visual C 5 0 ug Startup ug Vireo Driver Works ug Win32 SDK Online References Common ug Win32 SDK Tools Common ug Windows NT DDK o T ww Windows NT Workstation Fig 2 1 Double the NAP7000D icon to start it NAP7000D User Manual Version 1 0 8 When NAP7000D loading a window pop up that show the startup information about this software package By default the startup window will stay on about 3 second The user can disappear it by pressing the right button of the mouse During the startup time the NAP7000D will detect automatically the COM port that the CB 7000 module attach to the computer The startup information is shown as Fig 2 2 Power Adapater DC24Y Output 1 7060 1 7021 1 7012D 1 7520 Fig 2 2 The Startup information for NAP7000D NAP7000D User Manual Version 1 0 9 After startup information window disappear the NAP7000D s main window will be displayed as Fig 2 3 Also the detected COM port that CB 7000 module attached to the computer is displayed in the main window The user may change the COM port whenever he demand For example when pressing the right button of mouse during startup time to quit the startup information The displayed COM port may be wrong So the user must select the correct COM port that CB 7000 connected to the computer before he going on
6. 46 Fig 3 9 and Fig 3 10 show how to retrieve channel 1 s value and display its value in Excel DDE Conversation Channel tst 3 674 0 005 0 004 0 003 1 518 0 004 0 004 0 003 17th 2nd Microsoft Excel 2 3rd REE BEW BAD 6 IAD BAD MAW S x 5th Fig 3 9 To retrieve channel 1 s value into a cell by mean of MID function dst 3 674 0 005 0 004 0 004 1 518 0 004 0 004 0 004 2nd 3rd EFO RAD BEW HAD KAO IAD BAO Mew u 20128 5th Fig 3 10 The retrieved value displayed in the cell NAP7000D User Manual Version 1 0 47 3 3 Tutorial 3 One CB 7021 module the Output Value Controlled By Excel Working CB 7000 Module one CB 7520 and One CB 7021 Working Software NAP7000D and Excel Function To demonstrate how to passing the value from Excel to CB 7021 Working Steps Step 1 Setting the configuration of the CB 7021 as Fig 3 11 shown Please adjusting the baud rate and module address according to your CB 7021 module configuration In this case the A1 cell of Excel which contain the value passing to NAP7000D 70000 Ele COM Port Search Run DDE EU I 7000 Module og Configuration Setting 7021 Output Range 0 to 10 V Module Type 7021 Address Hex 0 20 C 4 20 0 10 Baud Rate 9500 M CheckSum Disable 0 10 Value
7. Setting 1 7000 Module Configuration x Configuration Setting Module 017 Selection for 7017 7018 Address He 4 Baud Rate 38400 CheckSum Disable Bee Wei ER Select All Unselect Al 10V Fig 2 14 The 7017 7018 Channel Selection window NAP7000D User Manual Version 1 0 22 Step 4 Entry the module address for the selected module Step 5 Select the exact baud rate in the Baud Rate Combo for the selected module Step 6 Select the status of checksum Disable or Enable Notice the status of checksum must be exact to your physical CB 7000 series module device If you select Enable you must to enable checksum status for CB 7000 module The default setting for CB 7000 series module is disable After above six steps the setting window shown as Fig 2 15 Setting 1 7000 Module Configuration x Configuration Setting Module Type n7 Address Hex 4 OK Baud Rate 540 gt CheckSum Disable Cancel The Found Out Module Remark 38400 10y Fig 2 15 After setting the module configuration Step 7 when Fig 2 15 display click OK button to accept the setting NAP7000D User Manual Version 1 0 23 The user can move the mouse point to the checked Conv8 Then press the right button of mouse to retrieve the setting inform
8. 2 6 Setting CB 7011 D CB 7012 D CB 7013 D CB 7014 D Stepl Check a ConvN here means 0 to 31 to start the setting CB 7000 module configuration In this example we check 0 for demos purpose as shown in fig 2 9 A user can check any ConvN to start its module configuration setting After checked a window titled setting CB 7000 Module Configuration will pop up We have to set the module type baud rate module address and checksum in this window for this DDE conversation working properly mi NAPTOOOD Ele COM Port Search Run DDE Display Establish Conversation DDE Ser Setting 7000 Module Configuration Configuration Setting Module Type Conv 1 Address Hex OK Conv2 Baud Rate peo Conv 4 Conv D Conv 5 ype ec ate Remark Conv B Conv 50 mSec T Fig 2 9 Check a ConvN to start module configuration setting NAP7000D User Manual Version 1 0 16 Fig 2 9 shown the state that hasn t performed searching process Setting 1 7000 Module Configuration NAP7000D User Manual Version 1 0 17 Step 2 Select the desired module type as method 1 or method 2 In this case please select 7012 as fig 2 10 shown Setting 7000 Module Configuration ES Configuration Setting Address Hex OK Cancel Baud Rate CheckSum Rem
9. NAP7000D Establish Conversation I m NEM mi E a LI Fig 2 3 The NAP7000D main window NAP7000D User Manual Version 1 0 10 2 2 The Menu of NAP7000D s main window The NAP7000D s main window contain 5 menus Those are File COM Port Search Run DDE and Display Ele COM Port Search Run DDE Display Establish Conversation ES COM Part DDE Server Conversations 2 rz 2 f Con 0 Conv8 Convi6 Conv24 Fig 2 4 The menu of NAP7000D s main window And the File main menu contain three sub menu These sub menu are Open Save and Exit COM Port Search Run DDE Display Open Save Exit Fig 2 5 The menu item in File menu The COM Port Search and Run DDE do not contain any sub menu The Display contains two sub menu those are Conv Setting Result and Search Result File COM Port Search Run DDE BEGNEN Conv Setting Result Search Result Fig 2 6 The menu item in Display menu The detail information about these menu described in the following section NAP7000D User Manual Version 1 0 11 2 3 Determine All CB 7000 Module Configurations In order to understand the configuration your remote control network comprised by CB 7000 module The user have to remember every module s configuration information The configuration information for a CB 7000 module includes module type ie 7520 7014 etc
10. 26 Setting 7021 Es Output Range 0 to 10 V 0 20 C 4 20mA 6 0 10 v Output ML TERRE por ean S Assigned 10 Value 5 Output ReadBack Output value 02 500 Value To output value via DDE link Service EXCEL Topic Item R1 C1 Fig 2 19 Control the desired output value of CB 7021 by Excel Step 3 Pressing one of these 3 command buttons to decide the output value Step 4 Entry the module address for the selected module In this case please enter 3 Step 5 Select the exact baud rate in the Baud Rate Combo for the selected module Step 6 Select the status of checksum Disable or Enable Notice the status of checksum must be exact to your physical CB 7000 series module device If you select Enable you must to enable checksum status for CB 7000 module The default setting for CB 7000 series module is disable After above six steps the setting window shown as Fig 2 21 NAP7000D User Manual Version 1 0 27 Setting I 7000 Module Configuration Es Configuration Setting Module Type Address Hex 3 OK Baud Rate pe CheckSum Disable Cancel The Found Out Module Fig 2 21 Step 7 when Fig 2 21 display click OK button to accept the setting 2 9 Setting CB 7041 CB 7052 CB 7053 Stepl Check a ConvN here means 0 to 31 to start the setting CB 7000 module configuration In
11. module s baud rate the module address in this network To record every module s configuration information would be a annoyed burden when constructing the network with large number CB 7000 modules Or it is necessary to understand every module s configuration information when adding a module into the original network in order to avoid conflict The NAP7000D facilitate the booking by performing the search process by clicking Search menu in the main window After performing Search a window titled To Find Out CB 7000 Module will display as fig 2 7 shown It is strongly recommended to perform search process firstly to easy the setting configuration for CB 7000 module NAP7000D User Manual Version 1 0 12 NAP7000D File COM Port Search Run DDE Display Find Out 1 7000 Module 38400 9600 4 DI 8 DO Searching Status COM Part ICOM2 Baud Rate 9600 Address 21Idecl 15fhexl In Searching press the mouse right button to stop Fig 2 7 The search window of NAP7000D Some information is shown to indicate that the searching status Initially the search range for module address is from 0 to FF hex The default COM port is the attached COM port detected in startup time as fig 2 3 shown And the baud rate may be choose among 115200 57600 38400 19200 9600 4800 2400 Please refer to sec 2 4 to choose the COM Port and baud rate for searching process During the search processing user can quit in any time by clic
12. a software package that facility user to establish the DDE hot link conversations between the NAP7000D and other Windows application After establishing these conversations they can exchange information each other For example a user can establish a conversation between NAP7000D to Excel Then he can pass the data from NAP7000D to a cell of a sheet in Excel Further the user can analysis these data in this sheet by mean of Excel build in function In the following chapter a tutorial with many examples are introduced that to guide the user to familiar NAP7000D With NAP7000D a user take advantage of the ability that to control the ICPCOM 7000 series module without having to code the program 17000 DLL and UART DLL The I7000 DLL and UART DLL are the DLL Dynamic Linking Library These two DLL consists of a set of functions for performing COM port operation For more detail information please refer to VAP7000P User Manual CB 7000 series module The CB 7000 is a family of network data acquisition and control modules They provide A D D A DI O Timer Counter and other function For more detail information please refer various user manual for CB 7000 series NAP7000D User Manual Version 1 0 7 2 The Operation of NAP7000D 2 1 Starting NAP7000D To start the NAP7000D click the Start in the task bar as Fig 2 1 shown 3 Accessories gj Startup Visual Basic 4 0 Command Prompt icpcom
13. means that the desired output value voltage for CB 7021 can be given with 3 ways as following Output Assigned Value to assign the output value directly Output ReadBack Value the read back value of CB 7021 as the desired output value Output via DDE link to output value of CB 7021 is controlled by DDE hot link as Fig 2 18 shown Fig 2 18 Control the CB 7021 output voltage by means of DDE link With the DDE hot link a user can control the CB 7021 without any programming When establishing the DDE hot link conversation the user must fill out Service Topic and Item fields in the 7021 setting window Usually the content in Service field is just the application s name such as Excel Genie The content in Topic field is the working sheet or document in the application such as sheet1 for Excel STRTGY 1 for Genie The content in Item field is the item s name that contain the value to be passed For examples DDES1 for Genie A cell in Excel will be referred to by the representation as row number and column number For example when using cell then the content in Item field would be And the C2 cell would be R2C3 Fig 2 19 show setting the DDE link to the Excel application The value in the A1 cell of sheet would be passed to the NAP7000D The NAP7000D controls the CB 7021 to output the desired voltage NAP7000D User Manual Version 1 0
14. operation system A PC compatible computer with Pentium chips 16 RAM Memory 2MB hard disk available space Starting Installation Insert disk 1 or disk 2 into your disk drive according to what platform 95 NT you using Then clicking Start in the task bar Enter A Setup as Fig 1 1 shown Click OK to start the install process Type the name of a program folder or document and Windows will open itfor you A setup exel Memini separate Cancel Browse WsStart Fig 1 1 install the NAP7000D NAP7000D User Manual Version 1 0 4 1 3 Un Installation Invoking Control Panel as Fig 1 2 shown Programs N Documents EF Settings Control Panel 3 Printers AJ Eind A Taskbar Windows NT Workstation Click Add Rem Programs icon in Control Panel to invoke Add Remove Programs Properties Select NAP7000D to uninstall NAP7000D User Manual Version 1 0 5 Add Remove Programs Properties fe Fm Accessibil Add Rem Options Programs Display Fonts 6 Mouse Multimedia Data Access Objects DAO 3 5 Internet Explorer 3 0 Microsoft Visual C 5 0 F 1 Vireo Driver Works 1 20 Ports Printers Fig 1 3 Uninstallation the NAP7000D NAP7000D User Manual Version 1 0 6 1 4 System Description NAP7000D The NAP7000D is
15. 14 SAVE AND OPEN THE SETTING FILE 37 2 15 To ExIT THENAP7000D rete rre ere re e ee an nie fette et rete edge te hee ss 38 NAP7000D TUTORIAL CT C 39 3 1 TUTORIAL 1 ONE CB 7017 MODULE eese eene enne nnne nnne nennen en 39 3 2 TUTORIAL 2 ONE CB 7017 MODULE AND PASSING DATA TO 43 3 3 TUTORIAL 3 ONE CB 7021 MODULE THE OUTPUT VALUE CONTROLLED BY EXCEL 48 3 4 TUTORIAL 4 ONE CB 7012 CB 7017 CB 7021 AND CB 7044 51 3 5 TUTORIAL 5 ONE CB 7012 CB 7017 CB 7021 AND CB 7044 MODULE WITH 53 NAP7000D User Manual Version 1 0 2 1 NAP7000D Introduction The NAP7000D is a hot link DDE Dynamic Data Exchange server The DDE is a communication protocol that enables to exchange data between windows application The NAP7000 pass the data acquired from CB 7000 module to other application by means of the hot link Or a user can control the CB 7000 module using the NAP7000D after establishing these hot link conversation The NAP7000D is a mouse driven system that provides the ability of developing CB 7000 application by just clicking mouse 1 1 The Contents of NAP7000D package The NAP7000D package includes one disk and one manual NAP7000D User Manual Version 1 0 3 1 2 Installation Before Installing please comfirm the following requirements Microsoft Windows 95 NT
16. 7044 ES Digital Input MSB Value 000000000000000 15 14 13 12 11 10 9 1 6 5 4 4 2 1 0 Digital Output MSB Value 99999999200 0000025 To output value via DDE link Service Output Assigned Topci EE Value Output via 5 Ne 1 utput Hea Item DDE link Back Value af Fig 2 25 The setting Configuration for 7044 window This window given some information about the CB 7044 module Because CB 7044 is digital input output module All the portion of Digital Input and Digital Output is active The user can set in all portion And the portion of Digital Input show that there are 4 digital input channels Digital Output show that there are 8 digital output channels When push Digital Input button in the Digital Input portion When push one command button among Output Assigned Value Output Read Back Value and NAP7000D User Manual Version 1 0 33 Output via DDE Link button in the Digital output portion This CB 7044 would perform the digital output function Step 4 Entry the module address for the selected module Step 5 Select the exact baud rate in the Baud Rate Combo for the selected module Step 6 Select the status of checksum Disable or Enable Notice the status of checksum must be exact to your physical CB 7000 series module device If you select Enable you must to enable checksum status for CB 7000 module The default setting for CB 7000 series modul
17. NAP7000D User Manual 4 W MEASUREMENT COMPUTING Revision 1 0 July 1998 NAP7000D User Manual Version 1 0 1 1 Table of Contents 3 1 1 THE CONTENTS OF NAP7000D PACKAGE 3 1 2 INIERUNT 4 1 3 UN INSTAELATIO N 3 ee teretes ert hs et a ete 5 1 4 SYSTEM DESCRIPTION e erede teer 7 THE OPERATION 8 2 l STARTINGINAP7000D detecte entree eret etate oe edere e ee P ede deme hus 8 2 2 THE MENU OF NAP7000D S MAIN entente 11 2 3 DETERMINE ALL CB 7000 MODULE CONFIGURATIONS 12 2 4 CHOOSE THE COM PORT AND BAUD RATE FOR nennen nennen 14 2 5 CONTROL CB 7000 MODULE WITH 7000 15 2 6 SETTING CB 7011 D CB 7012 D _ CB 7013 D 7014 16 2 7 SETTING THECB 7017 CB 7018 22 2 8 SETTING THEGCB 7021 i heh ete t te Ee EE eX ER RR deus rdi ee teres 25 2 9 SETTING CB 7041 CB 7052 CB 7053 cescccessesseseesseescseescesecseesecsecsecaeesecsaecaenseeaeesesaeeneeaeens 28 2 10 SETTING CB 7042 7043 AND 7067 nennen enne enne 31 2 11 3 2 12 DISPLAY THE SETTING RESULT erret eret conn das Pee e Y ete eere ee reete enitn 35 2 13 DISPLAY THE SEARCHING RESUL etre e ORE 36 2
18. P7000D Establish Conversation LI M MEM MEM MEM EM Fig 3 3 NAP7000D User Manual Version 1 0 41 After Run DDE is clicked a window title DDE Conversation Channel will pop up The input value for every channel is displayed in first conversation channel as Fig 3 4 These values may change every one second because the timer interval is set to 1000 mSec In this examples the input value of channel 0 of CB 7017 is 3 674V and the input value of channel 4 is 1 518V DDE Conversation Channel 3 674 0 005 0 004 0 003 1 518 0 004 0 004 0 004 Fig 3 4 Step 4 Click Quit command button to quit the DDE running NAP7000D User Manual Version 1 0 42 3 2 Tutorial 2 One CB 7017 module and passing data to Excel Working CB 7000 Module one CB 7520 and One CB 7017 Working Software NAP7000D and Excel Function To demonstrate how to control the CB 7017 by NAP7000D then passing data to excel Working Steps Step 1 Setting the configuration of the CB 7017 and select all channels Then click OK button to accept the channel selection Please referring Fig 3 1 Step 2 Enter the exact baud rate and module address according to your CB 7017 Then click the OK button to acc
19. ark qa D Fig 2 10 select the desired module If selecting 7012 D by method 1 then the following step3 step4 and step 5 is necessary If using method 2 then skip step3 step4 and step5 Step 3 Entry the module address for the selected module In this case please enter l Step 4 Select the exact baud rate in the Baud Rate Combo for the selected module In this case please select 9600 Step 5 Select the status of checksum Disable or Enable for your CB 7012D Notice the status of checksum must be exact to your physical CB 7012D module device If you select Enable you must to enable checksum status for CB 7012D The NAP7000D User Manual Version 1 0 18 default setting for CB 7000 series module is disable After about five steps the setting window shown as Fig 2 11 Setting 1 7000 Module Configuration E Configuration Setting Module Type Address Hex fh OK Baud Rate 15200 CheckSum Disable _ Cancel The Found Out Module Remark Fig 2 11 After setting the module configuration Step 6 when Fig 2 11 display click OK button to accept the setting or click Cancel button to cancel the setting After OK button is clicked the main window of NAP7000D display as Fig 2 12 to tell the user these setting step is completed NAP7000D User Manual Version 1 0 19 NAP7000D Establish Conversation se
20. at means the user can not set in this portion And the portion of Digital Output show that there are 13 digital output channel As the CB 7021 the user can decide the output value with 3 ways Those are Output Assigned Value Output ReadBack Value and Output via NAP7000D User Manual Version 1 0 31 DDE Link Step 4 Entry the module address for the selected module Step 5 Select the exact baud rate in the Baud Rate Combo for the selected module Step 6 Select the status of checksum Disable or Enable Notice the status of checksum must be exact to your physical CB 7000 series module device If you select Enable you must to enable checksum status for CB 7000 module The default setting for CB 7000 series module is disable The Step 4 Step 5 and Step 6 can be skipped if invoking setting Configuration for 7042 window with method 2 please referring Fig 2 10 Step 7 Clicking OK button to accept the setting NAP7000D User Manual Version 1 0 32 2 11 Setting CB 7044 CB 7050 CB 7060 Stepl Check a ConvN here means 0 to 31 to start the setting CB 7000 module configuration In this example the Conv17 is checked Step 2 Select the desired module type as Fig 2 10 shown method 1 or method 2 In this case please select 7044 7050 or 7060 In this examples the 7044 is selected Step 3 After selecting 7044 a window titled setting Configuration for 7044 will pop up as Fig 2 25 shown Setting Configuration for
21. ation And a information window would be toggled on as fig 2 16 shown Again pressing the right button may toggle off the information window NAP7000D Establish Conversation DDE Server Convers Fig 2 16 Toggle on the information window for 8 NAP7000D User Manual Version 1 0 24 2 8 Setting the CB 7021 Stepl Check a ConvN here means 0 to 31 to start the setting CB 7000 module configuration In this examples the Conv16 is checked Step 2 Select the module type as Fig 2 10 shown In this case please select 7021 After selecting 7021 then a window titled setting 7021 will pop up as fig 2 17 shown 7000 lol x Ele COM Port Search Run DDE Display 1 7000 Module Configuration x E Configuration 4 Module Type ozr Output Range 0 to 10 V Address Hex C 0 20 C 4 20 0 10 V poor Output Assigned i 0 0 i CheckSum Disak 49 Value lt Output ReadBack Output value 02500 Value The Found Out M To output value via DDE link Service Topic Output via Item DDE link Fig 2 17 The setting 7021 window NAP7000D User Manual Version 1 0 25 There are three command buttons in Fig 2 17 those are Output Assigned Value Output ReadBack Value and Output via DDE link It is
22. dow with method 2 please referring Fig 2 10 After above six steps the setting window shown as Fig 2 23 Setting 1 7000 Module Configuration Configuration Setting Module Type o1 Address Hex OK Baud Rate feo m CheckSum Cancel Remark Fig 2 23 Step 7 Clicking OK button to accept the setting NAP7000D User Manual Version 1 0 30 2 10 Setting CB 7042 CB 7043 and CB 7067 Stepl Check a ConvN here means 0 to 31 to start the setting CB 7000 module configuration In this example the Conv9 is checked Step 2 Select the desired module type as Fig 2 10 shown method 1 or method 2 In this case please select 7042 7043 or 7067 In this examples the 7042 is selected Step 3 After selecting 7042 a window titled setting Configuration for 7042 will pop up as Fig 2 24 shown Setting Configuration for 7042 Es Digital Inputs MSB Value 9099999999999999 Digital Input 15 14131211109 8 7 6 5 4 3 2 1 0 Digital Output MSB Value 990000000000000 EE To output value via DDE link Service Output Assigned Topci Value Output via 5 i utput Rea Item DDE link Back Value Fig 2 24 The setting Configuration for 7042 window This window given some information about the CB 7042 module Because CB 7042 is just a digital output module The portion of Digital input is gray th
23. e is disable The Step 4 Step 5 and Step 6 can be skipped if invoking setting Configuration for 7044 window with method 2 please referring Fig 2 10 Step 7 Clicking OK button to accept the setting NAP7000D User Manual Version 1 0 34 2 12 Display the Setting Result After setting the configuration for CB 7000 modules The user can get the setting information by click Display Conv Setting Result menu as Fig 2 26 shown Ele COM Port Search Run DDE DDE Server Conversations ConvO Conv8 Convi6 Convi Conv9 Convi Conv25 Fig 2 26 After click Conv Setting Result menu a window titled Display DDE Conversation Setting Information will pop up as Fig 2 27 shown The user can get whole information of all module setting It is facility utility that understanding the configuration of your remote control system Display DDE Conversation Setting Information ES Conv Index Type jec Other Information 7012 D 1 1 115200 Analog Input 7021 3 3 9600 Output Assign 2 3V 7017 4 4 38400 Analog Input Channels FF 7044 VI 9600 Output Assign DO 3 Fig 2 27 Display DDE Conversation Setting Information window NAP7000D User Manual Version 1 0 35 2 13 Display the Searching Result After searching the CB 7000 modules The user can get the searching result by click Display Search Result menu as fig 2 28 shown Fig 2 28 After click Sea
24. ept the configuration setting Please referring Fig 3 2 Step 3 Adjusting the timer interval according to your system performance Here we accept the default interval that is 1000 mSec Then click Run DDE to activate DDE hot link Please referring Fig 4 3 Step 4 Activating Excel Now we need establish DDE link between NAP7000D to Excel Here the NAP7000D act as DDE server that publishing the data And the Excel act as DDE client that receiving the published data The DDE client has the responsibility that creating the DDE link This require you to provide the name of Service Topic and Item of DDE server In NAP7000D the Service is NAP7000D the executed file name of NAP7000D The Topic is Form5 and Item is TextN here N means 1 to 32 according to the data in what conversation to be passed Usually in most Windows application the client combine these three names in following form to identify a DDE link ServicelTopic Item NAP7000D User Manual Version 1 0 43 Therefore specifying the DDE link with NAP 7000DlForms5 TextN where is 1 to 32 when working with NAP7000D Now selecting a cell of Excel for example A1 cell Then typing NAP7000DIFORMS TEXT1 into the cell as Fig 3 5 shown Then pressing Enter to accept the typing and the A1 will receive the data coming from NAP7000D as shown in Fig 3 6 DDE Conversation Channel 1st 3574 0 004 0 004 0 003 1 518 0 003 0 003 0 004 17th SX __
25. he CB 7017 and select all channels as Fig 3 1 shown Then click OK button to accept the channel selection Ele COM Port Search Run DDE Display Setting 7000 Module Configuration Configuration Setting Module Type 27017 Address Hex 4 4 OK Baud Rate 38400 7017 7018 Channel Selection d Channel Selection CheckSum i Y Channel Selection for 7017 7018 CHO M CH 2 WM CH3 The Found Out Module Iv CH5 M CHE Unselect All 4 NAP7000D User Manual Version 1 0 9 Fig 3 1 step 2 Enter the exact baud rate module address and checksum according to your CB 7017 configuration please referring Fig 2 10 as Fig 3 2 shown Then click the OK button to accept the configuration setting Emm 1 7000 Module Configuration E Configuration Setting Module Type n7 Address Hex 4 OK Baud Rate 540 gt CheckSum isse Cancel The Found Out Module Remark 38400 Fig 3 2 Accept the setting CB 7017 configuration NAP7000D User Manual Version 1 0 40 Step 3 Adjusting the timer interval according to your system performance Here we accept the default interval that is 1000 mSec It mean the period that the CPU perform the NAP7000D function call Then click Run DDE to activate the DDE hot link The main window of NAP7000D as shown in Fig 4 3 NA
26. k the Stop or Exit button And the searching result display in a window that represent the found module All the configuration information for every CB 7000 module will be displayed It is useful to debug the remote control network And when establishing the hot link conversation NAP7000D User Manual Version 1 0 13 2 4 Choose the COM Port and Baud Rate for Search Please following these steps to choose the COM port and baud rate that determine the searching range Select COM Port and Baud Rate EE Fig 2 8 Setting the COM Port and Baud Rates NAP7000D User Manual Version 1 0 4 2 5 Control CB 7000 module with NAP7000D Basically the NAP7000D divided the CB 7000 series module into six catalogues according to its function These six catalogues are listed as follows Analog Input with one channel These are CB 7011 D CB 7012 D CB 7013 D and CB 7014 D Analog Input with eight channels These are CB 7017 and CB 7018 Analog Output with one channel These is CB 7021 Digital Input Only These are CB 7041 CB 7052 and CB 7053 Digital Output Only These are CB 7042 CB 7043 and CB 7067 Digital Input and Digital Output Both These are CB 7044 CB 7050 and CB 7060 The setting configuration step is different for setting CB 7000 in these six catalogues The setting configuration step will be introduced in following content NAP7000D User Manual Version 1 0 15
27. onversation x COM Port DDE Server Conversations mj 2 ConvO Conv8 000 16 M Conv24 Display DDE Conversation Setting Information Other Information 115200 Analog Input 9600 Output Assign 3 3V 36400 Analog Input Channels FF 9600 Output Assign DO 3 NAP7000D User Manual Version 1 0 51 Fig 3 15 The various information for DDE conversation setting Step 2 Adjusting the timer interval according to your system performance Here we accept the default interval that is 1000 mSec It mean the period that the CPU perform the NAP7000D function call Step 3 Click Run DDE menu to start DDE hot link After Run DDE is clicked a window title DDE Conversation Channel will pop up The input output value for every CB 7000 module is displayed in first 4 conversation channels as Fig 3 16 There are 5 Conv the analog input value of CB 7012D 2nd The assigned analog output value of CB 7021 3rd The analog input value for each input channel of CB 7017 4th Conv The assigned output value of CB 7044 vo M A 3 3 h 2nd 330 3 674 0 005 0 003 0 002 1 518 0 003 0 003 0 002 Wh 5 DM ED 5 A X M b Jo sh 9h 3 3 3 DU X DM w UU wO3 3 X X DENM BU A wb amp amp DN lL wh OH
28. rch Result menu a window titled The searching Result will pop up as fig 2 29 shown The Searching Result an Module Address aud gh Low 3 3 9600 4 4 38400 7 7 9600 4 01 8 00 Fig 2 29 NAP7000D User Manual Version 1 0 36 2 14 Save and Open the Setting File After setting the configuration for CB 7000 modules The user can save the setting configuration information in a file with CON extension file name And retrieved the setting configuration information by open the saved file The Open and Save menu shown as fig 2 30 Ed NAP7000D Eile Conversation Li Li m im M MEM MEM im m Fig 2 30 Open Save the con file NAP7000D User Manual Version 1 0 37 2 15 To Exit the NAP7000D When want to exit NAP7000D the user can click Exit menu to exit the NAP7000D as shown in Fig 2 31 NAP7000D File Tonversation tri E M LI Fig 2 31 NAP7000D User Manual Version 1 0 38 3 NAP7000D Tutorial 3 1 Tutorial 1 One CB 7017 module Working CB 7000 Module one CB 7520 and One CB 7017 Working Software NAP7000D Function To demonstrate how to control the CB 7017 by NAP7000D Working Steps Step 1 Setting the configuration of t
29. t 7021 9600 Service excel Topic sheet1l Item ricl 7017 38400 Analog Input Channels FF 7044 9600 Service excel Topic sheetl Item r2cl Fig 3 18 Step 3 Click Run DDE button to start DDE hot link After that the DDE Conversation Channel window will pop up as Fig 3 19 shown is po 3rd 3 674 0 004 0 003 0 003 1 518 0 003 0 003 0 003 1966 mh _ a Fig 3 19 Step 4 Trying to change the value of A1 and A2 cell of Excel then the value in second and fourth conversation channel vary according to the value in A1 and A2 cell of Excel as shown in Fig 3 20 NAP7000D User Manual Version 1 0 55 0 720 3 450 3 674 0 003 0 003 0 003 1 518 0 003 0 003 0 12 3 45 12 Sheet Fig 3 20 NAP7000D User Manual Version 1 0 56
30. this example the 1 is checked Step 2 Select the desired module type as Fig 2 10 shown method 1 or method 2 In this case please select 7041 7052 or 7053 In this examples the 7041 is selected NAP7000D User Manual Version 1 0 28 Step 3 After selecting 7041 a window titled setting Configuration for 7041 will pop up as Fig 2 22 shown Setting Configuration for 7041 Digital Outputs Output via DDE link Dutpu Dack Va Fig 2 22 The setting Configuration for 7041 window This window given some information about the CB 7041 module Because CB 7041 is just a digital input module The portion of Digital Output is gray that means the user can not set in this portion And the portion of Digital Input show that there are 14 digital input channel Pressing the Digital Input button means this CB 7041 module perform the digital input function Step 4 Entry the module address for the selected module Step 5 Select the exact baud rate in the Baud Rate Combo for the selected module Step 6 Select the status of checksum Disable or Enable Notice the status of checksum must be exact to your physical CB 7000 series module device If you select Enable you must to enable checksum status for CB 7000 module The default setting for CB 7000 series module is disable The Step 4 Step 5 and Step 6 can be skipped if invoking setting Configuration for NAP7000D User Manual Version 1 0 29 7041 win