1. The operation method on Resistance test and Frequency test is identical to that of Voltage test Here just take Voltage test as an example for demonstration Click Voltage test to enter Fig 4 2 14 LAUNCH X 431 PAD Sensorbox User s Manual es TF 0000 00 Fig 4 2 Button descriptions Clear erases the currently displayed waveform and display it starting from the left Zoom In reduces the range and zoom in the waveform Zoom Out increase the range and zoom out the waveform Start starts or stops the testing process Adjustment adjust the range Return return to the previous interface 4 2 Test sample Knock sensor testing 1 Resistance test for knock sensor Switch ignition OFF unplug the wire connector of knock sensor test the resistance between the wire terminal and the case of knock sensor with Resistance test function it shall be disconnected and if it is OO conductive which means the knock sensor shall be replaced For the magnetostriction knock sensor it can also test the resistance by the Resistance measurement function the resistance shall be compliant with the specified value see specific service manual for the detailed data otherwise the knock sensor shall be 15 LAUNCH X 431 PAD Sensorbox User s Manual replaced 2 Checking for the output signal of knock sensor Unplug the wire connector of knock sensor check voltage between knock sensor connector termi
2. 1MQ no fault occurs Before disassembling the engine electrical control system cable cut off the power supply that is turn the ignition switch OFF and disconnect the cables on the battery poles Contact the test probe and the two terminals the two leads to be measured when measuring the voltage between the two terminals or the two leads Contact the red test probe to the terminal the cable to be measured and the black probe to the ground when measuring voltage of one terminal one cable When checking the continuity of the terminals contacts and leads the method for measuring their resistances can be used Check the faults in the terminals of the CEU to sensors relays etc There are two test probes in the testing wire The black one is the common signal terminal signal GND the red one is the input terminal for voltage resistance and frequency test and output terminal for simulation voltage simulation frequency and oxygen sensor Please choose the correct probes to match the different terminals 13 LAUNCH X 431 PAD Sensorbox User s Manual 4 Auto Multimeter 4 1 Main Menu Make sure X 431 PAD main unit and the sensorbox are properly connected Refer to Chapter 3 1 Connections for details power on X 431 PAD main unit and enter the function menu interface click Multimeter to display the test menu See Fig 4 1 Frequency test Fig 4 1 Click the desired test as shown on Fig 4 1 to perform related test
3. value duty cycle ratio and frequency of current square wave signal Start confirms the current operation LAUNCH X 431 PAD Sensorbox User s Manual Return returns to the previous interface After setting click Start to perform the test 3 2 3 Predefined waveform simulation X 431 PAD provides some common sensor waveforms which have been predefined to facilitate users to simulate sensor signals As long as you call out the predefined waveform then click Start to start simulating output of corresponding sensor waveform and no more parameter settings of simulation waveform are required In Fig 3 1 click Predefined waveform simulation to enter the screen shown as Fig 3 4 gt Predefined waveform simulation Please select predefined waveform a ee WER PEES E BERE ATA EA IRE ak a ee ee 8 Bae BE SOE NER E IRI RA Fig 3 4 Here click Select waveform button a screen similar to Fig 3 5 will appear LAUNCH X 431 PAD Sensorbox User s Manual Fig 3 5 In Fig 3 5 the upper left setting column stands for sensor types and the lower part indicates waveform Click to turn to next previous page The sensor types are explained as below ECT Coolant Temperature Sensor EVP EGR Valve Position Sensor HO2S Heated Oxygen Sensor IAT Intake Air Temperature Sensor MAF Mass Air Flow Sensor MAP Manifold Absolute Pressure Sensor TP Throttle Position Sensor VAF Volume Air Flow Sensor VSS Vehi
4. V1 00 000 2013 06 20 LAUNCH X 431 PAD Sensorbox User s Manual All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means of electronic mechanical photocopying and recording or otherwise without the prior written permission of LAUNCH This manual is designed only for the use of this unit LAUNCH is not responsible for any use of this manual on the other units The manual and all the samples herein can be changed without prior notice Neither LAUNCH nor its affiliates shall be liable to the purchaser of this unit or third parties for damages losses costs or expenses incurred by purchaser or third parties as a result of accident misuse or abuse of this unit or unauthorized modifications repairs or alterations to this unit or failure to strictly comply with LAUNCH operating and maintenance instructions LAUNCH shall not be liable for any damages or problems arising from the use of any options or any consumable products other than those designated as Original LAUNCH Products or LAUNCH Approved Products Notice other product names used herein are for identification purposes only and may be trademarks of their respective owners LAUNCH disclaims any and all rights in those marks This device is only for professional technicians and maintenance personnel Registered Trademark LAUNCH is a registered trademark of LAUNCH TECH CO LTD LAUNCH in Ch
5. al akai sail 4 ih ihn il taht al Ue Select Simulation Type DC voltage simulation Fixed frequency simulation Predefined waveform simulation Hand painted waveform simulation Fig 3 1 3 2 1 DC voltage simulation In Fig 3 1 click DC voltage simulation the interface is shown as Fig 3 2 are FS DC voltage simulation Current voltage 5 V Fig 3 2 In Fig 3 2 click the Settings button then click or to adjust the output LAUNCH X 431 PAD Sensorbox User s Manual voltage value Alternatively user can also click edit box then use the on screen keyboard to input the desired value directly After selecting or inputting the desired voltage based on the working characteristics of sensor click the Start button then the X 431 PAD will begin to output the simulation voltages Please note the red probe is the output terminal of simulation voltage Button descriptions Settings allows you to adjust the voltage Start confirms the current operation Return returns to the previous interface 3 2 2 Fixed frequency simulation This option enables you to simulate the square wave signal of pulse frequency of 0 1 15 kHz amplitude range of 5V 5 V and duty cycle 10 90 In Fig 3 1 click Fixed frequency simulation to enter a screen similar to Fig 3 3 Sas 3 Fixed frequency simulation Frequency 100 Hz Space Fig 3 3 Button descriptions Settings adjusts the voltage
6. ance is properly connected to the DLC to avoid communication interruptions During operation keep the screen upward and leveled Be careful when plugging and unplugging the main cable and diagnostic connector Tighten the screw before operation to avoid unexpected disconnecting and or damage to the port Handle with care Avoid collision Unplug the power after operation After the operation the stylus shall be inserted into its slot on the main unit and put away the cable and connector etc accessories to the box to avoid the lost Unplug the power cable by holding the connector not the cable itself LAUNCH X 431 PAD Sensorbox User s Manual Table of Contents DT FOREWORD cnnan rann eana arian 1 1 1 PRODUCT SUMMARY Y era nrnna ai ee a ar ia 1 T 2 PRODUCT FEATURES oee E E E E aE a r iara 1 1 3 PRODUCT FUNCTION ccccccccscscsccececececececesesecececseeeeeeeseseseeeseees 1 1 4 TECHNICAL PARAMETERS ccccccccscececececececececeeeceeeceseseeesseeeeeees 1 2 STRUCTURE AND ACCESSORIES uuu ccssssccssseccesssscccssnees 3 2 1 SENSORBOX STRUCTURE ssssssssssssssssssssssssssscsssssssssssssesseseeeees 3 2 2 SENSORBOX ACCESSORIES ssssssssssssssssssssssssssssesssssssssessseeeeeees 4 3 SENSOR SIMULATION ccssccccssssccesssscccssssccccssscccesssscccsssees 6 3JL CONNECTIONS inan tenes esos enthe ee eos ee a 6 3 2 SIMULATION TEST fecececcesccasee E ae Sie a 6 3 2 1 DC voltage simulation 7 3 2 2 Fixed freq
7. cle Speed Sensor For example click ECT Warm NTC Thermistor in Fig 3 5 the right screen will display the waveform of the sensor See Fig 3 6 10 LAUNCH X 431 PAD Sensorbox User s Manual LH ii ail PAN es chil Acs al kea Currently selected waveform ECT Warm NTC thermistor MAF Hot NTC thermistor Fig 3 6 In Fig 3 6 click OK button then the pre defined waveform has been set See Fig 3 7 LJ ihn alll Aaile haa hl aia a le Predefined waveform simulation Sensor Type ECT Waveform Name Warm NTC thermistor Fig 3 7 In Fig 3 7 click Start button to perform simulation test 11 LAUNCH X 431 PAD Sensorbox User s Manual 3 2 4 Hand painted waveform simulation This option offers great convenience for users to simulate special waveform or fault wave Users only draw the shape of waveform which needs to be simulated in left drawing area and then configure some parameters on the bottom namely high level low level and cycle of waveform then click Start X 431 PAD will output a waveform as desired Warning Just draw a complete periodic waveform when it is outputted the system will regard the waveform in the drawing area as a periodic one Users should draw an as large as wave in drawing zone so that the system can sample more points to reduce tolerance While drawing just pay attention to the shape of waveform high level low level and period can be ignored which can be set in the C
8. cy test The function utilizes the same hardware device as the sensor module 1 2 Product features DC voltage simulation Fixed frequency simulation Predefined waveform simulation Hand painted waveform simulation 1 3 Product function It features automotive sensor simulation test and multimeter test function 1 4 Technical parameters Sensorbox Parameters Scope Precision 5 Voltage range 5V 5V LAUNCH X 431 PAD Sensorbox User s Manual Max output current 70mA Predefined frequency range 0 150Hz Square wave signal pulse frequency 0 15KHz Square wave signal duty ratio 10 90 Multimeter Parameters Scope Precision 5 Voltage test Testing range DC 400V 400V Input impedance 10Mohm Resistance test Testing range 0 40Mohm Frequency test Testing range 0 25KHz Input impedance 1000Gohm Input voltage 1 12V LAUNCH X 431 PAD Sensorbox User s Manual 2 Structure and Accessories 2 1 Sensorbox structure 2 Fig 2 1 Structural diagram of Sensorbox Table 2 1 shows the ports and indicators for X 431 PAD sensorbox No Name Description 1 Data receiving Indicator green for receiving data from main unit indicator 2 Data sending Indicator green for sending data to main unit indicator 3 Power indicator It keeps steady on red after Sensorbox is powered on 4 B type USB port Connec
9. e sensorbox then connect the other end to the test probe or electronic control converting cable 3 Connect one end of the sensor test cable red into the VOQHz interface of the sensorbox and then connect the other end to the test probe or electronic control converting cable Note Choose corresponding cables and test probes according to different terminals 3 2 Simulation test Simulation test enables users to exactly judge if the sensor is good or not to avoid replacing components blindly For example the trouble code indicates the fault is in water temperature sensor itself But we need to confirm whether the fault results from water temperature sensor or the connections between ECU and sensors or ECU itself In this case we can make full use of simulation test to input the signal of simulating water temperature sensor instead of water temperature sensor to the microcomputer If the engine works better and the fault vanishes the fault is in the water temperature sensor If the fault still occurs input the signal to the corresponding terminals of ECU Consequently if the fault disappears the fault lies in the connection between water temperature sensor and ECU otherwise the fault exists in ECU After all connections are properly made refer to Chapter 3 1 for details power on and enter the function menu interface then click Sensor to enter the test selection screen See Fig 3 1 LAUNCH X 431 PAD Sensorbox User s Manu
10. ge shall be about 5V if the ignition switch is ON 16 LAUNCH X 431 PAD Sensorbox User s Manual Warranty THIS WARRANTY IS EXPRESSLY LIMITED TO PERSONS WHO PURCHASE LAUNCH PRODUCTS FOR PURPOSES OF RESALE OR USE IN THE ORDINARY COURSE OF THE BUYER S BUSINESS LAUNCH electronic product is warranted against defects in materials and workmanship for one year 12 months from date of delivery to the user This warranty does not cover any part that has been abused altered used for a purpose other than for which it was intended or used in a manner inconsistent with instructions regarding use The exclusive remedy for any automotive meter found to be defective is repair or replacement and LAUNCH shall not be liable for any consequential or incidental damages Final determination of defects shall be made by LAUNCH in accordance with procedures established by LAUNCH No agent employee or representative of LAUNCH has any authority to bind LAUNCH to any affirmation representation or warranty concerning LAUNCH automotive meters except as stated herein Disclaimer THE ABOVE WARRANTY IS IN LIEU OF ANY OTHER WARRANTY EXPRESSED OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Order Information Replaceable and optional parts can be ordered directly from your LAUNCH authorized tool supplier Your order should include the following information 1 Quantity 2 Part number 3 Item description Cus
11. ina and other countries In other countries where any of the LAUNCH trademarks service marks domain names logos and company names is not registered LAUNCH claims other rights associated with unregistered trademarks service marks domain names logos and company names Other products or company names referred to in this manual may be trademarks of their respective owners You may not use any trademarks service marks domain names logos or company name of LAUNCH or any third party without permission from the owner of the applicable trademarks service marks domain names logos or company name You may visit LAUNCH at http Awww cnlaunch com for the information of Launch s and the other specialized diagnostic tools or contact Launch by visiting http www X431 com or writing to Customer Center LAUNCH TECH CO LTD Launch Industrial Park North of Wuhe Avenue Banxuegang Bantian Longgang Shenzhen Guangdong P R China to request written permission to use materials on this manual for purposes or for all other questions relating to this manual LAUNCH X 431 PAD Sensorbox User s Manual Precaution on Operation The appliance is a sophisticated electronic device never have it clashed when in use Main unit screen may flash at the moment of engine ignition which is normal You may unplug the main unit if the program can not be actuated or confused screen occurs Plug again to continue the operation Make sure the appli
12. nal and ground wire of knock it should be output pulse voltage otherwise the knock sensor shall be replaced Coolant temperature sensor testing 1 Resistance test for coolant temperature sensor On vehicle testing Switch ignition OFF and unplug the wire connector of coolant temperature sensor then use the Resistance measurement to test the Resistance between two terminals of sensor The relationship between the resistance and the temperature is in inversely proportion negative temperature coefficient which shall be less than 1kQ during warming up Independent testing Unplug the wire connector of coolant temperature sensor then remove the sensor from the engine place the sensor into a breaker with water and heat the water then use the Resistance measurement to test the Resistance between two terminals of coolant temperature sensor at different water temperature Compared the measured value with the standard value if the Resistance is not compliant with the standard then the coolant temperature sensor shall be replaced 2 Output signal voltage testing for coolant temperature sensor After installing the coolant temperature sensor plug the wire connector of sensor and then switch ignition ON test the output signal voltage between the two terminals of wire connector The tested voltage shall be in inverse proportional with the coolant temperature When the harness of coolant temperature sensor is disconnected the volta
13. onfigure option In Fig 3 1 click Hand painted waveform simulation a screen similar to Fig 3 8 will appear Fig 3 8 Button descriptions Save save the current waveform Load loads the previously saved hand drawn waveform Settings sets the parameters of cycle high level and low level Select waveform click to call out the predefined waveform for reference Start continues the following operation 12 LAUNCH X 431 PAD Sensorbox User s Manual Return returns to the previous interface 3 2 5 Precautions on checking vehicle sensor Hold the connector when plugging or unplugging it Do not pull the cable for unplugging At first check the fuse fusible line and terminals Then check others after eliminating these faults When measuring voltage the ignition switch should be on and the battery voltage should not be less than 11V When measuring voltage please shake the lead lightly in the vertical and horizontal direction for more precision When checking whether there is open in the line disconnect the CEU and the relevant sensor at first then measure the resistance among the ports of sensor in order to determine whether open circuit contact fault exists or not When checking if there is a short in the line please disconnect the CEU and the relevant sensor then measure the resistance value of the ports between the connected port and the vehicle body If the resistance value is more than
14. t to main unit with USB cable when it is LAUNCH X 431 PAD Sensorbox User s Manual applied as separated USB device 5 Power Connect to power supply through the power connector adaptor 6 COM Common terminal of multimeter 7 VOHz Testing terminal of multimeter 2 2 Sensorbox accessories X 431 PAD sensorbox accessories include sensor test cable probe etc See Table 2 2 As the product configuration can be different the accessories included with the product may differ from the accessories listed on this manual Please see the packing list attached to the product for the detailed accessories Table 2 2 Accessory checklist No Name Picture 1 sensor test cable EZA 2 Sensor probe 3 Multimeter probe p 4 Electronic control converting cable 1 6 5 Electronic control converting cable 2 LAUNCH X 431 PAD Sensorbox User s Manual 6 Electronic control converting cable 3 _ _ 7 Electronic control converting cable 4 LAUNCH X 431 PAD Sensorbox User s Manual 3 Sensor Simulation 3 1 Connections 1 Firstly power on the main unit Connect one end of the power adaptor into the power interface of X 431 PAD main unit and the other end to the DC 12V power supply Alternatively it can be also powered by cigarette lighter cable and double clip power cord 2 Plug one end of the sensor test cable black into the COM interface of th
15. tomer Service Department If you have any questions on the operation of the unit please call 86 755 84528767 If your unit requires repair service return it to the manufacturer with a copy of the sales receipt and a note describing the problem If the unit is determined to be in warranty it will be repaired or replaced at no charge If the unit is determined to be out of warranty it will be repaired for a nominal service charge plus return freight Send the unit prepaid to Attn Customer Service Department LAUNCH TECH CO LTD 17 LAUNCH X 431 PAD Sensorbox User s Manual Launch Industrial Park North of Wuhe Avenue Banxuegang Bantian Longgang Shenzhen Guangdong P R China 518129 Launch website http www cnlaunch com 18 Statement LAUNCH reserves the rights to make any change to product designs and specifications without notice The actual object may differ a little from the descriptions in the manual in physical appearance color and configuration We have tried our best to make the descriptions and illustrations in the manual as accurate as possible and defects are inevitable if you have any question please contact local dealer or after sale service center of LAUNCH LAUNCH does not bear any responsibility arising from misunderstandings
16. uency simulation oossoo amp 3 2 3 Predefined waveform simulation scoscese 9 3 2 4 Hand painted waveform Simulation cccsccesseeeeereeeeee 12 3 2 5 Precautions on checking vehicle Sensor ossos 13 4 AUTO MULTIMETER cccsssscccsscsecccssscccessscccssssscccsssscseees 14 4 TMANMENU rianih in a E a 14 AZ TEST SAMPLE 334 cys oss53 05 b2005sognasg ns obo E E S 15 LAUNCH X 431 PAD Sensorbox User s Manual 1 Foreword 1 1 Product summary X 431 PAD is a new generation of sophisticated automotive diagnostic product with colorful screen and powerful functions developed by LAUNCH It provides an optional function of automotive sensor simulation test Sensor simulation test function is specially designed to diagnose and simulate vehicle sensor faults quickly and conveniently including DC voltage simulation Fixed frequency simulation Predefined waveform simulation and Hand painted waveform simulation Vehicle sensors are the signal input devices for electrical control systems which can transform all kinds of running parameters such as vehicle speed coolant temperature engine RPM air flow throttle opening etc into the electronic signal for the vehicle computer who can optimize the engine running status per the above mentioned parameters to keep the engine working in a prime status Meanwhile it integrates the functions of automobile multimeter which enables users to perform voltage resistance and frequen

Download Pdf Manuals

image

Related Search

Related Contents

ECON SERIES FP PUMP - RainHarvest Systems  Hoefer SQ33 Sequencer  Boldair Activ` gel destructeur d`odeurs Thé vert  YX-318 STAR-MOON LIGHT  Typhoon Wireless Audio Headset  Trion HE Plus 2000 User's Manual  Installation  Hama Traveller 150 Premium Duo  CableWholesale 10E2-02103 printer cable  Manual Domo Uno v1.0  