SYSTEM DESCRIPTION
Contents
1. Fire amp Security lt Dravida You can also find additional information at our website www bravidafireandsecurity com or www systemhuset com BRAVIDA INTEGRA Access control and alarm systems are essential for the implementation of security in commerce and industry as well as in public spaces Getting the best possible security at the best price is just as important as getting a fully functioning system with the best possible functionality BRAVIDA INTEGRA is an integrated security system for access control card production burglar alarms fire alarms and CCTV surveillance that provides excellent security at a reasonable price BRAVIDA INTEGRA is Simple to manage and it is fully possible to expand the system with additional customised functions BRAVIDA INTEGRA is Simple to integrate and external systems are easily managed through additional modules such as OPC Data Service and Alarm Service through our open interface Integra Easy Connect BRAVIDA INTEGRA has been developed to satisfy the market s stringent demands for functionality and ease of use This system description is intended to provide an overview of the system s components as well as to demonstrate the options and solutions that Bravida Integra has to offer For more detailed information please refer to the user manual consultant manual and the individual product sheets SYSTEM DESCRIPTION BRAVIDA INTEGRA V6 3 SYSTEM COMPONENTS Bravid
2. SYSTEM DESCRIPTION BRAVIDA INTEGRA V6 SYSTEM COMPONENTS HIN BCR SW WIRELESS PROXIMITY READERS FOR SMARTCARDS BCR SW BCR SW is the smart technology that enables mechanical locks to be wirelessly linked to Bravida Integra access control systems The heart of BCR SW is a short range wire less communications protocol designed to link with an online electronic access system with a BCR SW enabled mechanical lock A straightforward easy and convenient way to add more monitored doors to a security system BCR SW allows for online access control and management increasing both security and controllability BCR SW IS COMPATIBLE WITH MIFARE amp DES FIRE EV1 CARDS UID or sector reading otherwise Mifare Plus UID or sector reading BCR PD AND BCR P MINI PROXIMITY READERS FOR PROX EM MARIN BCR PD A BCR PD card reader is included in the Bravida Integra access system for contactless card reading The BCR PD has a keypad for use in door environments that require an access code The card reader is equipped with a built in antenna for card reading a clearly visible keypad LED indication internal buzzer and convenient display for graphical sym bols The card reader is protected against sabotage in a sturdy ABS case with an EIA485 interface The reader has Certification class SS EN 50131 3 2009 grade 4 BCR P Mini A BCR P Mini card reader is included in the Bravida Integra access system for contactless card reading
3. can then be connected to the PC network while it is online A fixed IP address is defined for the C node SYSTEM DESIGN Communication via LON Echelon FTT 10 LON bus communications are used for communications between the C nod and sub node S nod This method is intended for situations when there are multiple sub stations within a relatively small area The cable distances without using repeaters are comparatively long and cabling is easy Network cards are not necessary The C node has a built in communications port for LON communications with sub nodes Communications via Wi Fi RS485 bus communications are used for communications between the C node and radio hub for Wi Fi readers The cable distances without using repeaters are compara tively long and the cabling is easy The C node has two built in communications ports for RS485 communications HUB Wi Fi communications between a radio hub and BCR SW readers comply with TEEE 802 15 4 and define the medium access control and the physical layer for WSN It operates primarily in the 2 4 GHz band using 16 channels The bandwidth of each channel is 5 MHz The MAC employs the CSMA CA Carrier Sense Multiple Access with Collision Avoidance mechanism CCA Clear Channel Assessment is used in I I I the physical layer to determine the channel occupancy Distance between HUB and Wi Fi readers can be up to 25 meters 10 SYSTEM DESCRIPTION BRAVIDA INTEGRA V6 COMMUNICATIONS BETWEEN PCS SER
4. MAD SL 0 3 with card technology Mifare is based on the RFID techno 4 or 7 bytes in the same readers and time logy that is currently used in fields such as transport Mifare DesFire can be used with ISO TEC 14443 payment services and security for example The tech A unique serial numbers 7 bytes and random IDs nology is especially useful due to its capability to save Mifare DesFire cards can be used on multiple file data in several sectors on a card Reading can employ a system and fully compliant with ISO TEC 14443A part serial number a sector and MAD2 1 4 using optional ISO TEC 7816 4 commands security Card readers with Mifare technology read cards at levels The highest security level uses AES Advanced a distance of up to 5 cm from the reader CR80 Cards Encryption Standard encryption based on a 128 bit The read distance varies depending on the surroun key length This enables MIFARE DESFire EV1 to hold dings and any radio or metallic interference up to 28 different applications and 32 files per applica The cards for Mifare and Prox readers can be supp tion in its flexible file system lied as traditional cards or keyrings Credit card size The card readers are generally mounted in a door proximity cards CR80 can be combined with a mag environment with the S node door control unit in a netic strip and printed using a standard card printer sub assembly The lightweight format is easy to posi tion for ultimate user convenience 6
5. SYSTEM COMPONENTS CARD READERS Bravida Integra includes a number of different card reader models BCR that support proximity keycards such as EM Marin Mifare and DESFire All other card models that support Wiegand or data clock interfaces can be used including various types of biometric systems All SmartCard readers are ready for NFC reading BCR SD AND BCR S MINI PROXIMITY SMARTCARD READERS BCR SD BCR S Mini A BCR SD card reader is included in the Bravida Integra A BCR S Mini card reader is included in the Bravida access system for contactless card reading The BCR SD Integra access system for contactless card reading This has a keypad for use in door environments that require card reader has a sturdy design The card reader features an access code a built in antenna for card reading LED indication inter The card reader is equipped with a built in antenna for nal buzzer and an EJA485 interface with moulded plastic card reading a clearly visible keypad LED indication encapsulation internal buzzer and convenient display for graphical symbols The card reader is protected against sabotage in a sturdy ABS case with an ETA485 interface The reader has Certification class SS EN 50131 3 2009 grade 4 THE BCR SD AND BCR S MINI CAN READ MIFARE CLASSIC MIFARE AND DESFIRE EV1 CARDS UID sector reading and MAD with 4 or 7 bytes and NXP Semiconductor has developed the Mifare smart Mifare Plus UID sector reading and
6. This card reader has a sturdy design The card reader features a built in antenna for card reading LED indication inter nal buzzer and an EJA485 interface with moulded plastic encapsulation BCR PD AND BCR P MINI ARE COMPATIBLE WITH EM MARIN 4200 RO and 4550 RW in the same readers and time The card readers are generally mounted in a door environment with the S node door control unit in a sub assembly The lightweight format is easy to posi tion for ultimate user convenience EM Microelectronic Marin SA is a company in the Swatch Group that supplies chip technology suitable for access control This technology has become an industry standard and is used by numerous card and reader suppliers Card readers with EM Marin technology read the card at a distance of up to 12 cm from the reader The read distance varies depending on the surroundings and any radio interference Otherwise the reader has the same properties as a magnetic card reader The cards for Mifare and Prox readers can be supp lied as traditional cards or keyrings Credit card size proximity cards can be combined with a magnetic strip and printed using a standard card printer SYSTEM DESCRIPTION BRAVIDA INTEGRA V6 7 KEYCARDS PROXIMITY CARDS TAGS AND SMART CARDS RFID This technology is based on radio signals The card contains an integrated circuit that draws current from a coil in the card when the card is moved close to the reader The card therefore has no
7. battery and will continue to work provided there is no physical damage to the card or tag Credit card size cards are available These can also be combined with a magnetic strip or smart card chip Keyring tags of various designs are also available However tags do have a slightly shorter read distance Chip 13 56 MHz BRAVIDA INTEGRA NO 1 ON SMART CARDS With Bravida Integra V6 a lot of effort has gone into deve loping a simple administrative solution for smart cards Magnet Stripe m ge Encryption keys for Mifare sector reading and MAD can be downloaded from a central location using encrypted communications and without any separate programming of card readers Bravida Integra V6 supports several encryption keys in the same card reader for Mifare sectors and MAD reading which means that in addition to the customer s unique Chip 125 KHz keys the same system can also read cards from several suppliers e g SITHS county councils ID06 etc Contact Chip BRAVIDA INTEGRA V6 SUPPORTS EM Marin 4200 RO and 4550 RW Mifare Classic UID sector reading and MAD with 4 or 7 bytes Mifare Plus UID sector reading and MAD SL 0 3 with 4 or 7 bytes Mifare DesFire EV1 UID and AES encrypted Application reading 8 SYSTEM DESCRIPTION BRAVIDA INTEGRA V6 MIFARE CLASSIC Mifare Classic can be used with ISO IEC 14443 A unique serial numbers 4 or 7 bytes and random IDs The security level uses CRYPTO1 encryption based
8. on a 48 bit key length MIFARE PLUS Mifare Plus can be used with ISO IEC 14443 A unique serial numbers 4 or 7 bytes and random IDs Mifare Plus cards can be used on multiple security levels The highest secu rity level uses AES Advanced Encryption Standard encryption based on a 128 bit key length The lowest security level uses Cryptol To facilitate the migration process for existing infrastructures based on MIFARE Classic the MIFARE Plus chip on its lowest security level is back wards compatible with MIFARE Classic Cards using chips on this lowest security level can be switched to a higher security level Once a card is switched it can only operate on that higher secu rity level and cannot be switched back to a lower security level e Security Level 0 MIFARE Plus cards are pre personalised with confi guration keys level switching keys MIFARE Classic CRYPTO1 and AES keys for the memory e Security Level 1 On this level the cards are 100 functionally back wards compatible with MIFARE Classic 1K 4K cards Cards work seam lessly in existing MIFARE Classic infrastructures e Security Level 2 Mandatory AES authentication MIFARE Classic CRYPTO for data confidentiality e Security Level 3 Mandatory AES for authentication communications confidentiality and integrity Optional proximity detection MIFARE Plus X only MIFARE DESFIRE Mifare DesFire can be used with ISO IEC 14443 A unique serial numbers 7 bytes
9. select the Day period The periods that can be selected are e Date e Special days e Monday Friday e Monday Thursday e Saturday Sunday e Holidays A time zone is normally made up of Monday Friday Saturday Sunday and a holiday Calendar The calendar function is used to specify the function of a time zone on an unspeci fied holiday Analogue time zone An analogue time zone is used to limit functions by time for instance open doors with a time limit e g 30 min or buy time when bypassing burglar alarms SECURITY LEVELS The security level determines how the various card readers will function during the day 5 6 1 Security level A security level is created in the same way as a time zone but uses a day schedule for the security level A security level can be used by one or more card readers 5 6 2 Day schedule for security level A day schedule for a security level determines how a card reader will function during the day The options include Unlocked Usually a main entrance during normal working hours Card Usually a department door during normal working hours Locked Usually a back door during evenings Card PIN Normally all doors with a keypad during evenings at night Card Toggle Usually an office door that is opened closed regularly Card PIN Toggle As above but with PIN code GIN Group code PGIN Personal code SOFTWARE PLATFORMS AND FUNCTIONS Ess Day Schedule f
10. users to have their own passwords which are chosen by each user Operator User access will be defined for each user e How long the user will remain logged in e The time or date for which permission applies e Rules on how long a password remains valid e Number of characters in the password 1 15 e Rules for automatic blocking There is no limit to the number of users that can be defined All passwords are encrypted and stored in the database User groups Each user is assigned to a user group The various user groups receive different access rights to folders in the system Access to folders is configured for functions such as display change and delete There is no limit to the number of groups that can be configured VIII VIII VIII KK SEE 14 SYSTEM DESCRIPTION BRAVIDA INTEGRA V6 ALARM COLLECTION COLLECTING ALARMS Alarm inputs on S node An S node can be used as a combined door and I O node or solely as an I O node When used solely as an I O node it has 8 double balanced alarm inputs and 4 relay outputs ACKNOWLEDGE ALARMS ON AN ALARM LIST An alarm list of unacknowledged alarms can be shown on the screen Various colours are used to indicate status Active alarms appear in red Active acknowledged alarms appear in green etc For more information please refer to the user manual Alarms are assigned a presentation group The operator is assigned access to one or more pre
11. VERS AND C NODES mu MANAGEMENT WORKFLOW HR SYSTEM SYSTEM SYSTEM FIRE CCTV ALARM VISITOR BMS X C NODE ELEVATOR HUB AY m K v7 SA1 73 Si m m m A x C NODE ie fee CI CI C SOFTWARE PLATFORMS AND FUNCTIONS OPERATING SYSTEMS AND PROGRAMMING LANGUAGE The system employs a standard PC platform and is compatible with Windows XP Windows Vista Windows 7 Windows 8 and Microsoft Server 2005 Microsoft Server 2008 and Microsoft Server 2012 32 or 64 bit R2 DATABASE The system uses SQL Server as a database The actual database is normally MS SQL KM 2012 Express The full version of SOL Server can also be used The database is run as SQL Server 2012 a background program for Integra Server PC Bravida Integra is compatible with MS SOL 2005 2008 and 2012 64 bit R2 SOL Server Es SCREEN MANAGEMENT gt Administrative tasks are performed in an environment similar to Windows Explorer oniki The structure comprises folders and objects in the same way as Windows Explorer omen cose 3 i o Alarm C Groups Objects represent all users components and parameters present in the system oO Auer Instructions Folders with subfolders are created individually as required The system uses the drag and drop principle to move objects between folders and to link objects One example would be access permission for users ACCESS LEVELS The access permissions in the
12. a Integra A scalable system The software for Bravida Integra is scalable can be modified and is capable of handling both large and small systems The largest installations comprise thousands of door environments and alarm points while the smallest systems may have only a few BRAVIDA INTEGRA BASE For smaller systems that require a high level of security and user friendliness but have fewer door environments and alarm points BRAVIDA INTEGRA PREMIUM For medium sized to large systems or when you Want to integrate other products via one of the many inter faces supported by Bravida Integra Well structured and easy to use alarm graphics can be used to visu alise and manage alarm points BRAVIDA INTEGRA ENTERPRISE For large systems that demand high performance and functionality Well Structured and easy to use alarm graphics can be used to visualise and manage alarm points The system sizes above can be supplemented with a number of additional modules such as CCTV Data Service Guard Report Alarm Distribution Alarm Monitoring etc More information about these modules can be found in separate product sheets SYSTEM COMPONENTS MENE Substation C Node One C nodeG can handle up to 30 nodes for door environments and alarms or 30 wireless readers The node has an internal memory and database that handles local cards access rights time zones security levels and other integral functions in the
13. and random IDs Mifare DesFire cards can be used on multiple file system and fully compli ant with ISO TEC 14443A part 1 4 using optional ISO IEC 7816 4 commands security levels The highest security level uses AES Advanced Encryption Standard encryption based on a 128 bit key length This enables MIFARE DESFire EV1 to hold up to 28 different applications and 32 files per application in its flexible file system KEYCARDS mum Comparison between MIFARE products Memory size Protocol File system Keys crypto MIFARE Classic 1KB AKB ZCRYPTO1 keys per Sector Transmission Security gt neryption MIFARE Plus _ fF2KB 4KB I l 4180 14443 3 ISO 1444 3 lseT4443 4 Fixed Structure Fixed Structurg gt Sector MIFARE DESFire 2KB 4KB gt 8KB gt ISO 14443 4 Flexible File System 2 CRYPTOTkeys per Upto 14 AES keys per ZAES Keys per Sector apphcation e Encryption Encryption Encryption ___ MAC Plaint MAC Plain MAC Piain M FARE card reset COMMUNICATIONS BETWEEN SERVERS AND C NODES COMMUNICATIONS VIA ETHERNET IP VPN TCP IP communications over a network is the best option when communications involve units at multiple geographic locations The C node is equipped with a network card for communications over Ethernet via TCP IP protocols The substation
14. ard reader for each floor A physical card reader is installed in the lift Virtual card readers are added at access levels making it possible to assign different access levels to each floor if there are doors present When the card is read by the card reader in the lift a relay is activated for each floor to which access is granted The relays are connected to the lift control unit The buttons for the floors to which the cardholder has access are now activated The lift control solution can be used for several functions like one reader for several doors or cabinets SMS TO MOBILE PHONES System messages can be sent to a mobile phone as SMS messages Messages are sent to third party software using the SMTP protocol The Omnigate software forwards alarms via a telephone with a SIM card 16 SYSTEM DESCRIPTION BRAVIDA INTEGRA V6 ELEVATOR NODE INTERFACES WITH OTHER SYSTEMS Bravida Integra can interact with other systems We have chosen to integrate card production and alarm collection management in Bravida Integra In addition Bravida Integra can be integrated with other systems using a variety of interfaces CCTV SYSTEMS Bravida Integra can be integrated with a CCTV platform such as Ethiris from Kentima Milestone and Detec This integration occurs during OPC communications between Bravida Integra and the CCTV platform One example of its use is if an indoor alarm on the Bravida Integra side is triggered wh
15. ich in turn relays a message via OPC communications to the Ethiris CCTV plat form stating that the program may need to change the layout or display data from a PTZ camera Here is an example of a PTZ camera being triggered to start recording an event in this case an alarm from an IR detector OPC INTERFACE Bravida Integra includes an OPC server and OPC client This makes a number of solutions possible for interaction with other systems One example is displaying messages from components and controlling components in the Integra system from a host presentation system OPC CLIENT amp SERVER With an OPC client Bravida Integra can among other things receive and display alarms and handle instructions from other systems With an OPC server the Integra system can control functions in other systems The OPC client is also used in integration with other system like CCTV platforms FIRE ALARMS There is an interface in Bravida Integra for Autronica s fire alarm panels for example The idea behind this integration is that fire alarms can be presented and displayed as a part of Bravida Integra s alarm graphics The alarms can also be displayed using Integra s presentation system DATABASE INTERFACES FOR HR DATABASES There is a program module that has been developed for exchanging data with other databases For example student registries or other personnel databases This function can automate and simplify card administration fo
16. or Time Zone BB Unlocked 07 16 amp jes Name Unlocked 07 16 Schedule Description List of References Select hour 0 1 2 3 4 5 6 7 8J9f10 11 12f13114 15 16 17f18119 20 21 22 23 Security Level status Hl unlocked B Locked IB 2 Cards E cin Z Card Toggle Z 2 Cards PIN NM Personal GIN Card PIN Toggle Transparent LI Card B Door Safe Card L Card PIN NM Door Safe Card PIN L 00 00 10 20 30 40 50 minutes SYSTEM DESCRIPTION BRAVIDA INTEGRA V6 13 SYSTEM SECURITY COMMUNICATIONS ETTE Between servers and substations EE Communications between servers is possible over different communications interfa ces Regardless of the type of communications data can be encrypted which increa ses security Between substations and door environmenis Communications between substations and door environments nodes are via LON in FTT 10 This of communications type can also be encrypted LON FTT 10 Encryption of the communications between the host and card reader is AES128 DATABASE and if using Mifare Plus SL3 amp DesFire EV1 AES128 encryption between the card and Microsoft SQL Server is used as the system database The necessary security Microso card reader as well systems are built in with MS SQL For more detailed information please refer to the document C2 Administrator s and User s Security Guide PASSWORD PROCEDURES Bravida Integra requires
17. r large access systems with many users TERMINAL SERVER CLIENTS Bravida Integra Client can be run on thin clients Citrix Client connected to a termi nal server The Bravida Integra Server software is installed on an external server PC and connected to Citrix Terminal Server via a network Please contact us for more information about this solution OO BRAVIDA INTEGRA CCTV SYSTEMS SYSTEM DESCRIPTION BRAVIDA INTEGRA V6 17 Dravida Fire amp Security 46 0 8 602 30 00 Mikrofonvagen 28 SE 126 81 Stockholm Sweden www bravidafireandsecurity com or www systemhuset com
18. sentation groups This can be used for example to alert maintenance perso nal of technical alarms and security guards of burglar alarms GRAPHICAL AND DYNAMIC ALARM PRESENTATION The system features an integrated graphical presentation of alarms Alarms can be immediately displayed on a zone map and doors can be opened remotely from the map MANAGEMENT OF ALARMS IN CARD READERS An alarm zone that may comprise one or more alarm points can be defined for the system Various actions can be implemented for card readers with keypads and displays e Alarm zones can be switched off and on e Buy alarm bypass time e Transmission of status of current areas zones e Triggered alarms can be shown on the card reader display e Inhibit points e Etc Authorisation to handle alarms can be assigned to any card user and by any reader in the system PRESENTATION AND MANAGEMENT a snsnnenenssssssenan Name Alarm yelelD Type a Card Reader S Node 30 Cp Rejected Aj amp Card Access amp S Node 30 C NodeG2 In E amp Card Reader Node 30 0 amp ComHub 1 8 Test 8 0247 A OPC Client Bravida Integr amna Aeon Block Unblock Device offli Device offli Locate in alarm picture re SYSTEM DESCRIPTION BRAVIDA INTEGRA V6 15 SPECIAL FUNCTIONS LIFT CONTROL The standard C node is used for access control in lifts The solution makes it possible to define a virtual c
19. system Information is always retrieved from the internal database This means that all principal information and functionality is also available in offline mode Memory management is implemented in the C nodeG2 that enables you to split databases and store a huge number of access cards 250 000 cards have been tested A C nodeG2 can communicate with a host system on TCP IP The C nodes and underlying units are supplied with DC power from a separate bat tery pack with two 40 Ah batteries or larger if so required This provides sufficient power for several hours of operation in the event of a power outage Various nodes for door controls and alarms are connected to substations S node The S node is a door alarm system suitable for high security doors It can also be used purely as an I O unit that stores alarms and performs any actions required When the S node is used as a door node eight inputs and eight outputs are availa ble and when it s used as an alarm node eight inputs and two outputs are available rr The S node communicates with a host C node on LON bus FTT 10 and is sabota mr per ge proof and is powered with 24 VDC and has an output with a 12 VDC supply for alarm detectors The output can handle up to 1 A All inputs can be defined as digital or double balanced ComHub The ComHub is a door box for 1 8 BCR SW wireless readers The ComHub communicates with a host C node on RS485 ComHub is powered by 24 VDC NE
20. system are based on a combination of card readers zz9gn Pine SE 253 3 Each card reader can be linked to a time zone for when a card with specific rights 1n003dadaduaDE ss yo gz can be used Access permission can also be linked to access the setting for bistable opening when a card reader is used to set a door to permanent open mode TIME ZONES Time zone settings are found in Day schedule for time zones and Time zone In addition the system also has an Analogue time zone setting TE ee n SE ae gt R 5 0n 16 08 oc C fe Name On 16 08 Schedule Description List of References Select hour 011121314151617 819DoT12131415116117118113 20 21 22 23 Day schedule for time zones The day schedule defines periods within each 24 hours when a time zone will be on and off One minute intervals are used The period is defined using the left and right C Transparent Le mouse buttons for on and off respectively and can be highlighted using the mouse cursor to change periods within the 24 hour period The day schedule follows the predefined time period 12 SYSTEM DESCRIPTION BRAVIDA INTEGRA V6 Time zone comprising day schedule Time zones are used for normal time controlled functions such as restricted access to doors A time zone is made up of several day time zones A day time zone can last for several days for a single activity This is determined in the field used to