        Port-A-Cool 16-Inch Pneumatic Evaporative Cooler User Manual
         Contents
1.  AIR HORN TO    AND SHIPPING PALLET    2  ROTATE HORN SUPPORT AND SUPPORT  BAR AWAY FROM ORANGE HOUSING   PANEL AND THEN TO AIR HORN     AIR HORN THIS    REMOVE  5  ATTACH GREEN    1     16ASSB   LY DWG  DRAWN BY  M  CARL  4 24 00               YO       N            3 8    DIA      2    LG  BOLTS    2  FLATWASHER  AND NUTS       3  LOCATIONS    PNEUMATIC FRAME    GROUND LINE  SUPPORT BAR  PUMP AIR LINE  CONTROL PANEL  FACTORY ATTACHED    HORN SUPPORT  TO AIR MOVER    TO CONTROL PANEL    PAGE A 1    www sylvane com 1 800 934 9194    PAC2K24AD                               MeMa   PARTA   meme   PARTE  7  A  CASTERS   12   PUMPADO    2  CASTERS 2K1  13   HOSEFMiS    DRAIN 01  4  AIRHORN 10 7  15   HOSE FTG 05_  6   Fomo   17   SPRY             8   HOSE M PACH2K24    o   PACPLB   20   CONTROL    PAC PLB 07  a   PADs          www sylvane com 1 800 934 9194    PAC2K36AD s       PART   CASTERS 2k L   12    PUMP AD 01   CASTERS 2K L  DRAIN 01  FAN 20 AD  FLAP  e     _ 8  CS    FLOAT 02  HOSE FF4   18  HOSE M24 01  HOSE FM  PAC PLB 1   21   PACH2K36  11   PADs048 G    PAC PLB       
2.  Support Hot Line  888 266 5243  U S  only  or email Tech Support at  support port a cool com for the nearest stocking distributor     www sylvane com 1 800 934 9194    VI  EVAPORATIVE COOLING    The PORT A COOL   unit is a fully self contained  portable  high efficiency evaporative cooler     The PORT A COOL   unit is proudly made in America at our Center  Texas factory        A  What is Evaporative Cooling    When trying to understand evaporative cooling  it may be best to think of air as being like  a sponge  Similar to a sponge  air has an ability to absorb moisture that it comes in contact  with  The amount of moisture that the air will absorb depends on the condition of the   air  or specifically  how much moisture the air already contains and the temperature of  the air  If the air is warm and contains only a small amount of moisture  it will more read   ily absorb moisture  As air cools  its volume decreases  and with it  its ability to absorb  moisture decreases  After all  how easily you can clean up a spill depends on how dry the  sponge is that you are using     The term    relative humidity    describes the quantity of water in the air in relation to its  total capacity  Any volume of air at any given temperature has an ability to hold a certain  quantity of moisture  If the air contains 20  of its total capacity to hold moisture  the rela   tive humidity is said to be 20   Whereas  a humidity of 100  indicates that the air at this  temperature and pressure is ho
3.  The  PORT A COOL   unit must be level on its base     When the PORT A COOL   unit is placed near a wall or other obstruction  it is recom   mended that a distance of at least 3 feet from the wall or obstruction to the face of the  cooling pads is maintained  This allows the unrestricted flow of warm air to the front of the  PORT A COOL   unit  When using multiple PORT A COOL   unit units in close prox   imity  be sure to aim the   PORT A COOL   unit so that the air flows compliment each other  Opposition will  negate the air flow and allow an area of dead air to accumulate between the two or more  PORT A COOL   unit units     B  Filling with water   Refer to Section I  Part D  and connect the water supply line  Turn on your supply valve    and allowing the PORT A COOL   unit sump tank to fill with water  Once the sump tank  is full  the float valve will shut off the supply flow     www sylvane com 1 800 934 9194    C  Starting the pump and adjusting the water flow   pads should be in place      CAUTION   DO NOT RUN PUMP WHEN SUMP IS DRY     Once the sump tank is full  the pump may be started by opening the pump valve which is  the smaller of the two 1 4 turn air valves  With this valve open the amount of water may  be adjusted by using the pneumatic flow control valve to obtain the desired amount of  water placed on the pads  This procedure is the same on all pneumatic models  Spray bar    valve must be open     When  initially turning on the pump  the level in the sump will
4.  drop suddenly and restart  the flow of supply water  This is a normal condition as the cooling pads require a large  amount of water for proper wetting     When the PORT A COOL   unit is new  the new pads will require an initial    breaking in       period  This period is required to start the pads absorbing the water into the paper  It may  take up to a week before maximum efficiency is reached     D  Starting the fan air mover    Cooling pads must be installed and caster brakes must be engaged      CAUTION   MAKE SURE THE GREEN GROUND LINE ATTACHED TO THE    PORT A COOL IS ATTACHED TO A GOOD GROUND TO  ELIMINATE STATIC ELECTRIC CHARGES        Only the 36    reaction fan model  PAC2K36AD  has a rotating fan to move the air  This  unit is started by slowly opening the large 1 4 turn air valve on the control panel on the  side of the unit  The regulator is preset at the factory to obtain maximum output  This 1 4  turn air valve may be adjusted to provide the required output     The 24    and 16   models  PAC2K24AD  amp  PAC2K16AD  utilize a venturi air amplifier to  accomplish the air movement required  These units are also factory adjusted to the maxi   mum pressure flow rate  This 1 4 turn air valve may be adjusted to provide the required  output     With the air  amp  pump on and the pads wet  it is now possible to make fine adjustments to  the water flow for maximum cooling performance     Adjust the flow where the pads appear to have a few dry streaks in them     This co
5. T A COOL   unit  Water should now be entering through  the float valve to fill the sump tank     To verify that your connections are well made  manually lift the float Gn all models  in the  float valve until it seats against the top of the valve housing  The water flow should stop  and the inlet connections may now be visually checked for leaks  paying particular atten   tion to the hose connection to the float valve and the connections to the bulkhead fitting   these connection may loosen during shipment     The cooling pads may now be replaced by reversing the removal operation above in  Section I  Paragraph B     www sylvane com 1 800 934 9194    Compressed Air Connection       Before connecting compressed air to the PORT A COOL   unit be sure that both the Jet  Fan or Air Mover and the Pump shut off valves are closed  The air is connected by way of  a Crow   s foot type bayonet connector  This connection is made by placing the matting  together where the rubber seals are touching and then twisting the input hose connector  90 deg  clockwise while pressing the two fittings together  A pin should then be inserted  into the two holes to provide a secure and safe attachment     INLET  PRESSURE    MODEL          PAC2K36AD 196 scfm 9 100 cfm  PAC2K24AD 164 scfm 4 898 cfm  PAC2K16AD 83 scfm 2 200 cfm       AIR DRIVE CONSUMPTION RATES    www sylvane com 1 800 934 9194    11  OPERATING PROCEDURES    A  Placement of the PORT A COOL   unit     PORT A COOL   unit should be used in w
6. alve and opening the Drain Valve  If it is desired  a  hose may be attached to the Drain Valve to direct the drained water to a remote disposal  area  Once the Drain Valve is open  starting the pump will drain the unit  On the 16 inch  model  a simple drain plug in the sump tank may be removed and the sump drained     Once the sump is drained and the power disconnected  the pads may be removed to  allow inspection of the sump tank  Assuming that the PORT A COOL   unit is in a dusty    environment  a lot of the dust will be collected in the sump tank  This dirt may be vacu   umed out using a wet dry shop vacuum and wiped clean with a cloth     C  Storage  Storage of the PORT A COOL   unit is very simple     1  Drain all water from the sump tank and clean as above  ensuring that the pads and  sump are completely dry     2  Disconnect air supply hose and roll up to insure that they will not be rolled over   tripped over or caught in equipment     3  Cover the PORT A COOL   unit completely to prevent dust build up and store in a  dry area  This also helps prevent damage to the pads     www sylvane com 1 800 934 9194    IV  TROUBLESHOOTING   REPAIR       A  Troubleshooting    The most common problems with a PORT A COOL   unit are operational  meaning that  the PORT A COOL   unit does not operate properly  The PORT A COOL   unit consists of  three systems  It is important to determine which system of the PORT A COOL   unit the  problem is associated with  This may not always be obv
7. d housing to insure effective direct   ing of the air over the water san rated media at the proper air velocity  The PORT A   COOL   unit has incorporated all of these features and more     As explained in PART B of this section  the effectiveness of the PORT A COOL   unit is  best appreciated when it is above 85  F and below 75  relative humidity  By the time the  outside temperature reaches 85  F  the humidity is almost always below 75   The two go  hand in hand     ASSEMBLY DRAWING FOR 16    www sylvane com 1 800 934 9194         ORES OS SONO SO SO SO OSI  BERR                                                              OOOO SOS   SR RS SOLOS YO SOS SOS SOS SOS SORDO   ORO ROS LOS SO SOS ORO OSOS DORIA   OSOS RROS SOLOS SOLOS ON SSS             e OSLO ROSSO ROSSO LOS OIR DOLO ARIS                          A CNA KOON    DK  gt  LANADI ANAD   AX X Nh NAVs SACI NAO NLA AL RARER NR RIND   BORER  SVEN                                                                                                              ROE ROO                     ROSS LOS LIO    oe ORSON RIO IIS    PES           NNN    IS FOR A EARTH GROUND    GROUND WIRE TO  TO CONTROL STATIC ELECTRICITY     OSORIO TOOL RIOS ORO NNN                                               ERROR  E SS SE  A                 UNIT FROM SHIPPING BOX          PORT A COOL W  3 8    BOLTS  FLATWASHER     amp  NUTS SUPPLIED   4  ATTACH RED AIR LINE TO FILTER    ATTACH SUPPORT BAR TO ALUM  FRAME    W  SUPPLIED PIN   3  REMOVE PADS TO ATTACH
8. ell ventilated areas only     There are three primary considerations when deciding where to place the  PORT A COOL   unit     1  Fresh Air Supply   The rear of the PORT A COOL   unit  pad area  must be placed  so as to insure a smooth  uninterrupted supply of fresh air     2  Air Pattern   The cool air discharged from the PORT A COOL   unit should have a  clear area to circulate in  as free of obstruction as possible     3  Ventilation  Exhaust    There should be a defined place in which the air from the  PORT A COOL   unit can be exhausted from the area being cooled  This is to pre   vent the PORT A COOL   unit from recirculating air that has already been through  the cooling process     A primary consideration when actually deciding where to place PORT A COOL   unit is  the direction of the air flow  The PORT A COOL   unit creates a fan shaped air pattern  that disburses the air over a large area  This pattern may be disturbed or broken up by  obstacles such as shelves  work benches  etc  It is important to insure that a clean  unbro   ken path for the air from the PORT A COOL   unit is provided to ensure the maximum  circulation possible     It may be desirable to raise the PORT A COOL   unit above any low obstructions in  order to increase the overall coverage  When raising the height of the PORT A COOL    unit  insure that the platform constructed for holding the PORT A COOL   unit is stable   well constructed  level and will not allow the PORT A COOL   unit to tip over 
9. ese two models require assembly before operating  See page A l for  assembly information     B  Removing the cooling media   Disconnect air source     Caution   Disconnect air supply before performing this operation      The PORT A COOL   unit should now be exposed to allow removal of the cooling media   pads   On the 36    and 24    model  the front flap and the pad screen   if installed  must be  removed to allow access to the cooling pads  Start with the center pad  which should be  tilted out from the top and lifted out of the drain trough  The two pads to either side of the  center pad may then be removed in the same manner  Should you desire to remove the two  outside pads  they must first be pulled sideways toward the center of the PORT A COOL    unit until they clear the side retainer  They may then be removed as the other pads     C  Connecting the water and compressed air     Water Connection  PORT A COOL   unit must be upright and sitting on a  stable surface      After the PORT A COOL   unit has been thoroughly tested at the factory  the special  female female adapter is connected to the brass bulkhead connector on the left side of  the PORT A COOL   unit  when looking at the fan side   Simply attach a standard garden  hose to the brass female female adapter     Verify that the rubber hose washer is in place before attaching  and tighten the fitting to  guarantee that a secure connection is made  Once the hose connection is made  water  may be turned on to the POR
10. ious in that certain problems may be  associated with more than one system     When determining which system that the problem is associated with  you must first  define the problem  i e  the pump is not operating  Although this might seem a bit over   simplified  this particular problem may be caused by several things  So while defining the  problem  a careful check of all systems should be made to fully understand the extent of  the problem     If you are having difficulty determining the exact problem it is best to contact the distribu   tor from whom the PORT A COOL   unit unit was purchased  The distributors are fac   tory trained and will be able to have your PORT A COOL   unit unit repaired quickly     V  REPLACEMENT PARTS  Warranty Replacement Parts    Replacement parts may be acquired from the distributor from which you purchased the  PORT A COOL   unit  If you are not certain from whom the PORT A COOL   unit was  purchased please call the Port A Cool  LLC Technical Support Hot Line  888 266 5243  or  email Tech Support at support port a cool com and have the serial number of your unit  ready  The serial number will help us determine whom the appropriate distributor is  the  model of PORT A COOL   unit and how best to locate the required parts     Non Warranty Replacement Parts    Again replacement parts should be ordered from the distributor from which you pur   chased the PORT A COOL   unit  If you are unable to acquire the necessary parts please  call the Technical
11. lding all the moisture it can  If the air has a low relative  humidity when entering the PORT A COOL   unit  then it has the ability to hold more  moisture  and will thus evaporate more water and cool more effectively     When describing the amount of moisture in the air  the term relative humidity is used  because the    sponginess    of air changes relative to air temperature  The warmer the air   the more spongy it becomes  and the more water it can hold  That is to say that air that  has a 100  relative humidity can hold no more water vapor  However  if the air is heated     it expands  and as a result the relative humidity decreases even though the total amount of  water vapor in the air has not changed  As a result  we must describe the level of humid   ity relative to the condition of the sponge we are talking about  Is it a 50  F sponge or an  80  F sponge  An 80  F sponge will hold more water at 50  humidity than a 50  F sponge     How is cooling produced  In order to evaporate water  heat  energy  is required  In fact   the evaporation of one gallon of water requires almost 8 700 BTU   s of heat  Where does  this heat come from  From whatever the water is in contact with as it evaporates  This  could be a hot sidewalk  your body  a tree  from the air itself or a wet cooling pad As the  heat is removed from an object  the temperature of that object is decreased   in this case   the air     It is important to realize that the temperature of the water does not have a g
12. low  an evaporative cooler to work well     Since any evaporative cooling device must evaporate water to achieve cooling  more  water vapor is put into the air  As the ambient relative humidity increases  it becomes  more difficult to put moisture into the air  The efficiency of any evaporative cooling  device is directly related to its ability to evaporate water  cool  at a given relative humid   ity  A unit with low efficiency will cool only at low relative humidity levels  while a unit  with high efficiency can achieve effective cooling at much higher humidity levels     8    www sylvane com 1 800 934 9194    C  Evaporative Cooling and the PORT A COOL   unit     The PORT A COOL   unit is the state of the art  high efficiency  portable evaporative  cooling device  High Efficiency  rigid cooling media coupled with a unique patented  housing design allows the PORT A COOL   unit to cool effectively in very high relative  humidity conditions  Conditions that no other portable evaporative cooling device  such  as the old style swamp cooler  could possibly approach     The public has an initial tendency to equate the PORT A COOL   unit with the    swamp  cooler     and in reality the only thing that they have in common is that they are both evap   orative coolers  much as the    73 model automobile and    96 model automobile are both  cars  The key to efficient evaporative cooling is using a specially designed  high efficiency   rigid cooling media contained in a properly designe
13. ndition of having a few vertical dry streaks in the pads indicates that the supply of  water is sufficient to the pads without being extreme     When turning the unit off at the end of the day or week  the pump should be turned off  about 15 minutes before the air movement system to allow the cooling pads to dry  This  will enhance the life of the pads     www sylvane com 1 800 934 9194    III  MAINTENANCE     STORAGE    Very little maintenance is actually required on the PORT A COOL   unit  Most of the  maintenance on the PORT A COOL   unit is cleanliness  Keeping the PORT A COOL    unit clean will do more than any other single item to keep your new PORT A COOL    unit in peak operating condition  The rugged  corrosion resistant construction of the  PORT A COOL   unit and industrial grade components make for the low maintenance  characteristics of the PORT A COOL   unit     A  Daily Maintenance    Daily maintenance is really more an operational consideration than actual maintenance   On a daily basis  the pump should be turned off approximately 15 minutes before the fan  is turned off  This will allow the cooling pads to dry out and help extend their life  help   ing to control the growth of mildew  mold  bacteria and other odor causing elements     B  Weekly Maintenance    At the end of the week or at a scheduled time  the unit should be shut down and the  sump tank should be drained  On the 36  and 24 inch models  this is accomplished by  closing the Spray Bar Adjustment V
14. rease or decrease in the ability of the air to contain water vapor     If the temperature increases without an increase in the pressure  the result is a decrease  in the relative humidity  and thus an increase in its ability to hold more moisture  That is  to say that in the morning the humidity may be high  but as the day passes and the tem   perature increases the relative humidity will naturally decrease     The extent to which relative humidity decreases through the day can be affected by local  weather systems and proximity to large bodies of water  If an increase in temperature  accompanied by a weather system containing moisture moves in  the drop in humidity  will not be as great Nevertheless  the fact remains that relative humidity does drop as air  temperature increases  In fact  for every 20  F rise in temperature  the moisture holding  ability of air doubles  For instance  if the temperature of the air was 70  F and the relative  humidity was 100  at 5 a m   and the temperature increased to 90  F at noon  the mois   ture holding ability of the air would double As a result  the air would now be holding only  half of the moisture it is capable of holding  and the relative humidity of the air would  drop to 50      The hotter the day  the drier the air becomes  and the more cooling that can take place  through the evaporation of water  This means that when the day gets hot enough to  require cooling  the relative humidity will be much lower than in the morning and al
15. reat effect  upon the cooling produced through the evaporation  If you were to place a gallon of 50  F  water on a warm sidewalk  it would produce 9 000 BTU   s of cooling by consuming the  heat to perform the evaporation  A gallon of 90  F water would produce 8 700 BTU   s of  cooling  only a three percent difference  After all  if you were sprayed with water at either  of these temperatures on a hot day  you would still feel much cooler     www sylvane com 1 800 934 9194    The following table demonstrates the BTU   s removed from the air based on a given  amount of water consumed in an hour by the PORT A COOL   unit     U  S  Gallons   Hour Total BTU   s Removed  10  37 8 liters or 8 3 Imperial Gallons  87 000    12  45 4 liters or 10 0 Imperial Gallons  104 400  14  53 0 liters or 11 7 Imperial Gallons  121 800       In simple terms  evaporative cooling is nature s way of cooling  The PORT A COOL    unit utilizes the same phenomenon  but in the most efficient manner possible     B  Humidity and Evaporative Cooling     A cubic volume of air at a certain temperature and pressure has the ability to absorb   and hold a certain amount of water vapor  If that volume ne of air contains 50  of the  amount of moisture that it is capable of holding  it said to be at 50  relative humidity   The higher the temperature of the air  the higher the amount of moisture it is capable of  holding  Any change in the temperature without a corresponding change in the pressure  results in an inc
16. www sylvane com 1 800 934 9194    Port A Cool  unit    series 2000  Pneumatic Ownet s  Manual       FOR PNEUMATIC MODELS  PAC2K36AD  PAC2K24AD  PAC2K16AD     y  porteaecoo  KUUL  a    MANUFACTURED BY PORT A COOL  LLC    www sylvane com 1 800 934 9194    PORT A COOL   unit  OWNERS MANUAL    PNEUMATIC MODELS    PAC2K36AD  PAC2K24AD  PAC2K16AD       I  SETUP  A  Unpacking the PORT A COOL   unit   B  Removing the cooling pads   C  Connecting the water and air     II  OPERATING PROCEDURES  A  Placement of the PORT A COOL   unit   B  Filling with water  C  Starting the pump and adjusting the water flow   D  Starting the fan     III  MAINTENANCE  amp  STORAGE  A  Daily Maintenance  B  Weekly Maintenance  C  Storage    IV  TROUBLESHOOTING  A  Troubleshooting    V REPLACEMENT PARTS  A  Ordering Replacement Parts    VI  EVAPORATIVE COOLING  A  What is Evaporative Cooling   B  Humidity and Evaporative Cooling   C  Evaporative Cooling and the PORT A COOL   unit     www sylvane com 1 800 934 9194    I  SETUP  A  Unpacking the PORT A COOL   unit     The pneumatic PORT A COOL   unit models   PAC2K36AD  PAC2K24AD  PAC2K16AD    are packed according to the model  The 36    reaction fan model  PAC2K36AD  is crated  on a wooden pallet  This model comes completely assembled and thus weighs in excess  of 460 Ibs  It should be handled with caution   The 24    and 16    models   PAC2K24AD   PAC2K16AD  are shipped in one large package on a single pallet  The air mover is in an  individual package  Th
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
EPSON NEC 社労士支援ソフト 社労夢 プリンタ設定ガイド  Simca 5-6 - DEPANOTO - Pièces et accessoires pour automobiles  Samsung Galaxy K zoom Brugervejledning    Philips SA1929 2GB* Flash audio player  PARSEC User Manual    USER`S MANUAL - GSI Highway Products  SPECIALE - Società italiana di Endodonzia      Copyright © All rights reserved. 